1
|
Brombal L, Arfelli F, Brun F, Di Trapani V, Endrizzi M, Menk RH, Perion P, Rigon L, Saccomano M, Tromba G, Olivo A. Edge-illumination spectral phase-contrast tomography. Phys Med Biol 2024; 69:075027. [PMID: 38471186 PMCID: PMC10991267 DOI: 10.1088/1361-6560/ad3328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 02/23/2024] [Accepted: 03/12/2024] [Indexed: 03/14/2024]
Abstract
Following the rapid, but independent, diffusion of x-ray spectral and phase-contrast systems, this work demonstrates the first combination of spectral and phase-contrast computed tomography (CT) obtained by using the edge-illumination technique and a CdTe small-pixel (62μm) spectral detector. A theoretical model is introduced, starting from a standard attenuation-based spectral decomposition and leading to spectral phase-contrast material decomposition. Each step of the model is followed by quantification of accuracy and sensitivity on experimental data of a test phantom containing different solutions with known concentrations. An example of a micro CT application (20μm voxel size) on an iodine-perfusedex vivomurine model is reported. The work demonstrates that spectral-phase contrast combines the advantages of spectral imaging, i.e. high-Zmaterial discrimination capability, and phase-contrast imaging, i.e. soft tissue sensitivity, yielding simultaneously mass density maps of water, calcium, and iodine with an accuracy of 1.1%, 3.5%, and 1.9% (root mean square errors), respectively. Results also show a 9-fold increase in the signal-to-noise ratio of the water channel when compared to standard spectral decomposition. The application to the murine model revealed the potential of the technique in the simultaneous 3D visualization of soft tissue, bone, and vasculature. While being implemented by using a broad spectrum (pink beam) at a synchrotron radiation facility (Elettra, Trieste, Italy), the proposed experimental setup can be readily translated to compact laboratory systems including conventional x-ray tubes.
Collapse
Affiliation(s)
- Luca Brombal
- Department of Physics, University of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
- INFN Division of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
| | - Fulvia Arfelli
- Department of Physics, University of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
- INFN Division of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
| | - Francesco Brun
- INFN Division of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
- Department of Engineering and Architecture, University of Trieste, Via A. Valerio 10, I-34127 Trieste, Italy
| | - Vittorio Di Trapani
- Department of Physics, University of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
| | - Marco Endrizzi
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, GWC1E 6BT, London, United Kingdom
| | - Ralf H Menk
- INFN Division of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
- Elettra-Sincrotrone Trieste S.C.p.A, I-34149 Basovizza Trieste, Italy
- Department of Computer and Electrical Engineering, Midsweden University, Holmgatan 10, Sundsvall, Sweden
| | - Paola Perion
- Department of Physics, University of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
- INFN Division of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
| | - Luigi Rigon
- Department of Physics, University of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
- INFN Division of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
| | - Mara Saccomano
- Helmholtz Zentrum München, Helmholtz Pioneer Campus, Ingolstädter Landstraße 1, D-85764 Neuherberg, Germany
| | - Giuliana Tromba
- Elettra-Sincrotrone Trieste S.C.p.A, I-34149 Basovizza Trieste, Italy
| | - Alessandro Olivo
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, GWC1E 6BT, London, United Kingdom
| |
Collapse
|
2
|
Precise phase retrieval for propagation-based images using discrete mathematics. Sci Rep 2022; 12:18469. [PMID: 36323686 PMCID: PMC9630448 DOI: 10.1038/s41598-022-19940-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 09/06/2022] [Indexed: 11/17/2022] Open
Abstract
The ill-posed problem of phase retrieval in optics, using one or more intensity measurements, has a multitude of applications using electromagnetic or matter waves. Many phase retrieval algorithms are computed on pixel arrays using discrete Fourier transforms due to their high computational efficiency. However, the mathematics underpinning these algorithms is typically formulated using continuous mathematics, which can result in a loss of spatial resolution in the reconstructed images. Herein we investigate how phase retrieval algorithms for propagation-based phase-contrast X-ray imaging can be rederived using discrete mathematics and result in more precise retrieval for single- and multi-material objects and for spectral image decomposition. We validate this theory through experimental measurements of spatial resolution using computed tomography (CT) reconstructions of plastic phantoms and biological tissues, using detectors with a range of imaging system point spread functions (PSFs). We demonstrate that if the PSF substantially suppresses high spatial frequencies, the potential improvement from utilising the discrete derivation is limited. However, with detectors characterised by a single pixel PSF (e.g. direct, photon-counting X-ray detectors), a significant improvement in spatial resolution can be obtained, demonstrated here at up to 17%.
Collapse
|
3
|
Ghani MU, Yan A, Fajardo LL, Wu X, Liu H. Dual-energy phase retrieval algorithm for inline phase sensitive x-ray imaging system. OPTICS EXPRESS 2021; 29:26538-26552. [PMID: 34615087 PMCID: PMC8687111 DOI: 10.1364/oe.431623] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 07/16/2021] [Accepted: 07/17/2021] [Indexed: 06/13/2023]
Abstract
Phase retrieval is vital for quantitative x-ray phase contrast imaging. This work presents an iterative method to simultaneously retrieve the x-ray absorption and phase images from a single x-ray exposure. The proposed approach uses the photon-counting detectors' energy-resolving capability in providing multiple spectrally resolved phase contrast images from a single x-ray exposure. The retrieval method is derived, presented, and experimentally tested with a multi-material phantom in an inline phase contrast imaging setup. By separating the contributions of photoelectric absorption and Compton scattering to the attenuation, the authors divide the phase contrast image into two portions, the attenuation map arises from photoelectric absorption and a pseudo phase contrast image generated by electron density. This way one can apply the Phase Attenuation Dualiby (PAD) algorithm and Fresnel propagation for the iteration. The retrieval results from the experimental images show that this iterative method is fast, accurate, robust against noise, and thus yields noticeable enhancement in contrast to noise ratios.
Collapse
Affiliation(s)
- Muhammad U. Ghani
- Advanced Medical Imaging Center and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Aimin Yan
- Advanced Medical Imaging Center and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Laurie. L. Fajardo
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT 84132, USA
| | - Xizeng Wu
- Department of Radiology, University of Alabama at Birmingham, Birmingham, AL 35249, USA
| | - Hong Liu
- Advanced Medical Imaging Center and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019, USA
| |
Collapse
|