1
|
Atigossou OLG, Demers MH, Paquet MP, Bradet-Levesque I, Campeau-Lecours A, Routhier F, Flamand VH. Usability of mechanical assistive technologies for performing activities involving the upper extremities in individuals with impairments: a systematic review. Disabil Rehabil Assist Technol 2024:1-20. [PMID: 38864384 DOI: 10.1080/17483107.2024.2356833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Accepted: 05/13/2024] [Indexed: 06/13/2024]
Abstract
PURPOSE To conduct a systematic review on the impacts of using mechanical assistive devices on function, performance in activities and participation of persons with upper extremity impairments, and to synthesize the strengths and limitations of these devices. METHOD Three independent reviewers conducted systematic searches of articles published between 2003 and 2023 in Compendex, Inspec, Embase, PubMed/Medline, IEEE Xplore, and Web of Science, as well as manual searches on the RESNA website for conference papers over the same period. The methodological quality of articles was appraised using the QualSyst tool. RESULTS From the 34 retained studies, 28 mechanical devices were identified and classified into two categories: (1) mobile arm supports (MASs) designed to perform multiple activities, and (2) devices used to assist with a specific activity of daily living (ADL). Overall, MASs helped users to perform manual activities in elevation and/or against gravity. Specific ADL devices allowed users to perform unique activities requiring fine motor skills such as opening a medicine container. Some of these devices have advantages like portability, adaptability, low cost, and ease of use. Limitations most often reported included interference or mobility restraints. CONCLUSION This review synthesizes the impacts of mechanical devices on the three domains of the International Classification of Functioning, Disability and Health (ICF) for individuals with upper extremity impairments. Impacts regarding function and performance in activities were more often measured than participation. Future studies should include outcomes related to participation, as taking this aspect into account might favor successful continued use of assistive devices.
Collapse
Affiliation(s)
- Orthelo Léonel Gbètoho Atigossou
- School of Rehabilitation Sciences, Faculty of Medicine, Université Laval, Quebec City, Canada
- Center for Interdisciplinary Research in Rehabilitation and Social Integration, Centre Intégré Universitaire de Santé et de Services Sociaux de la Capitale-Nationale, Quebec City, Canada
| | - Marie-Hélène Demers
- School of Rehabilitation Sciences, Faculty of Medicine, Université Laval, Quebec City, Canada
- Center for Interdisciplinary Research in Rehabilitation and Social Integration, Centre Intégré Universitaire de Santé et de Services Sociaux de la Capitale-Nationale, Quebec City, Canada
| | - Marie-Philippe Paquet
- School of Rehabilitation Sciences, Faculty of Medicine, Université Laval, Quebec City, Canada
- Center for Interdisciplinary Research in Rehabilitation and Social Integration, Centre Intégré Universitaire de Santé et de Services Sociaux de la Capitale-Nationale, Quebec City, Canada
| | - Isabelle Bradet-Levesque
- School of Rehabilitation Sciences, Faculty of Medicine, Université Laval, Quebec City, Canada
- Center for Interdisciplinary Research in Rehabilitation and Social Integration, Centre Intégré Universitaire de Santé et de Services Sociaux de la Capitale-Nationale, Quebec City, Canada
| | - Alexandre Campeau-Lecours
- School of Rehabilitation Sciences, Faculty of Medicine, Université Laval, Quebec City, Canada
- Center for Interdisciplinary Research in Rehabilitation and Social Integration, Centre Intégré Universitaire de Santé et de Services Sociaux de la Capitale-Nationale, Quebec City, Canada
| | - François Routhier
- School of Rehabilitation Sciences, Faculty of Medicine, Université Laval, Quebec City, Canada
- Center for Interdisciplinary Research in Rehabilitation and Social Integration, Centre Intégré Universitaire de Santé et de Services Sociaux de la Capitale-Nationale, Quebec City, Canada
| | - Véronique H Flamand
- School of Rehabilitation Sciences, Faculty of Medicine, Université Laval, Quebec City, Canada
- Center for Interdisciplinary Research in Rehabilitation and Social Integration, Centre Intégré Universitaire de Santé et de Services Sociaux de la Capitale-Nationale, Quebec City, Canada
| |
Collapse
|
2
|
Nguyen CM, Uy J, Serrada I, Hordacre B. Quantifying patient experiences with therapeutic neurorehabilitation technologies: a scoping review. Disabil Rehabil 2024; 46:1662-1672. [PMID: 37132669 DOI: 10.1080/09638288.2023.2201514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 04/06/2023] [Indexed: 05/04/2023]
Abstract
PURPOSE Neurorehabilitation technologies are a novel approach to providing rehabilitation for patients with neurological conditions. There is a need to explore patient experiences. This study aimed; 1) To identify available questionnaires that assess patients' experiences with neurorehabilitation technologies, and 2) where reported, to document the psychometric properties of the identified questionnaires. MATERIALS AND METHODS Four databases were searched (Medline, Embase, Emcare and PsycInfo). The inclusion criteria were all types of primary data collection that included neurological patients of all ages who had experienced therapy with neurorehabilitation technologies and completed questionnaires to assess these experiences. RESULTS Eighty-eight publications were included. Fifteen different questionnaires along with many self-developed scales were identified. These were categorised as; 1) self-developed tools, 2) specific questionnaire for a particular technology, and 3) generic questionnaires originally developed for a different purpose. The questionnaires were used to assess various technologies, including virtual reality, robotics, and gaming systems. Most studies did not report any psychometric properties. CONCLUSION Many tools have been used to evaluate patient experiences, but few were specifically developed for neurorehabilitation technologies and psychometric data was limited. A preliminary recommendation would be use of the User Satisfaction Evaluation Questionnaire to evaluate patient experience with virtual reality systems.
Collapse
Affiliation(s)
- Chi Mai Nguyen
- University of South Australia, Allied Health and Human Performance, Adelaide, Australia
| | - Jeric Uy
- University of South Australia, Allied Health and Human Performance, Adelaide, Australia
| | - Ines Serrada
- University of South Australia, Allied Health and Human Performance, Adelaide, Australia
| | - Brenton Hordacre
- University of South Australia, Innovation, Implementation and Clinical Translation (IIMPACT), Health Allied Health and Human Performance, Adelaide, Australia
| |
Collapse
|
3
|
Fernandes da Silva JLG, Barroso Gonçalves SM, Plácido da Silva HH, Tavares da Silva MP. Three-dimensional printed exoskeletons and orthoses for the upper limb-A systematic review. Prosthet Orthot Int 2024:00006479-990000000-00211. [PMID: 38175034 DOI: 10.1097/pxr.0000000000000318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 11/17/2023] [Indexed: 01/05/2024]
Abstract
This systematic review aims to assess and summarize the current landscape in exoskeletons and orthotic solutions developed for upper limb medical assistance, which are partly or fully produced using 3-dimensional printing technologies and contain at least the elbow or the shoulder joints. The initial search was conducted on Web of Science, PubMed, and IEEEXplore, resulting in 92 papers, which were reduced to 72 after removal of duplicates. From the application of the inclusion and exclusion criteria and selection questionnaire, 33 papers were included in the review, being divided according to the analyzed joints. The analysis of the selected papers allowed for the identification of different solutions that vary in terms of their target application, actuation type, 3-dimensional printing techniques, and material selection, among others. The results show that there has been far more research on the elbow joint than on the shoulder joint, which can be explained by the relative complexity of the latter. Moreover, the findings of this study also indicate that there is still a gap between the research conducted on these devices and their practical use in real-world conditions. Based on current trends, it is anticipated that the future of 3-dimensional printed exoskeletons will revolve around the use of flexible and high-performance materials, coupled with actuated devices. These advances have the potential to replace the conventional fabrication methods of exoskeletons with technologies based on additive manufacturing.
Collapse
|
4
|
Li B, Cunha AB, Lobo MA. Effectiveness and Users' Perceptions of Upper Extremity Exoskeletons and Robot-Assisted Devices in Children with Physical Disabilities: Systematic Review. Phys Occup Ther Pediatr 2023; 44:336-379. [PMID: 37635151 DOI: 10.1080/01942638.2023.2248241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 07/26/2023] [Accepted: 08/02/2023] [Indexed: 08/29/2023]
Abstract
AIM Systematically determine the effectiveness and users' perceptions of upper extremity (UE) exoskeletons and robot-assisted devices for pediatric rehabilitation. METHODS PubMed/Medline, Web of Science, Scopus, and Cochrane Library were searched for studies with "exoskeletons"/"robot-assisted devices", children with disabilities, effectiveness data, and English publication. Intervention effectiveness outcomes were classified within components of the International Classification of Functioning, Disability, and Health, Children and Youth Version (ICF-CY). Secondary data (users' perceptions; implementation setting) were extracted. Risk of bias and methodological quality were assessed. Descriptive analyses were performed. RESULTS Seventy-two articles were included. Most evaluated body structure and function and activity outcomes with less emphasis on participation. Most effects across all ICF-CY levels were positive. Devices were primarily evaluated in clinical or laboratory rather than natural environments. Perceptions about device effectiveness were mostly positive, while those about expression, accessibility, and esthetics were mostly negative. A need for increased rigor in research study design was detected. CONCLUSIONS Across populations, devices, settings, interventions, and dosing schedules, UE exoskeletons and robot-assisted devices may improve function, activity, and perhaps participation for children with physical disabilities. Future work should transition devices into natural environments, design devices and implementation strategies to address users' negative perceptions, and increase research rigor.
Collapse
Affiliation(s)
- Bai Li
- Department of Physical Therapy, Biomechanics & Movement Science Program, University of Delaware, Newark, DE, USA
| | - Andrea B Cunha
- Department of Physical Therapy, Biomechanics & Movement Science Program, University of Delaware, Newark, DE, USA
- Department of Physical Therapy, Munroe Meyer Institute, University of Nebraska Medical Center, Omaha, NE, USA
| | - Michele A Lobo
- Department of Physical Therapy, Biomechanics & Movement Science Program, University of Delaware, Newark, DE, USA
| |
Collapse
|
5
|
Gaudet G, Raison M, Achiche S. Current Trends and Challenges in Pediatric Access to Sensorless and Sensor-Based Upper Limb Exoskeletons. SENSORS (BASEL, SWITZERLAND) 2021; 21:3561. [PMID: 34065366 PMCID: PMC8161080 DOI: 10.3390/s21103561] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 05/14/2021] [Accepted: 05/18/2021] [Indexed: 12/21/2022]
Abstract
Sensorless and sensor-based upper limb exoskeletons that enhance or support daily motor function are limited for children. This review presents the different needs in pediatrics and the latest trends when developing an upper limb exoskeleton and discusses future prospects to improve accessibility. First, the principal diagnoses in pediatrics and their respective challenge are presented. A total of 14 upper limb exoskeletons aimed for pediatric use were identified in the literature. The exoskeletons were then classified as sensorless or sensor-based, and categorized with respect to the application domain, the motorization solution, the targeted population(s), and the supported movement(s). The relative absence of upper limb exoskeleton in pediatrics is mainly due to the additional complexity required in order to adapt to children's growth and answer their specific needs and usage. This review highlights that research should focus on sensor-based exoskeletons, which would benefit the majority of children by allowing easier adjustment to the children's needs. Sensor-based exoskeletons are often the best solution for children to improve their participation in activities of daily living and limit cognitive, social, and motor impairments during their development.
Collapse
Affiliation(s)
- Guillaume Gaudet
- Department of Mechanical Engineering, Polytechnique Montréal, Montréal, QC H3T 1J4, Canada; (M.R.); (S.A.)
- Marie-Enfant Rehabilitation Center, Research Center of Ste-Justine University Hospital Center, Montreal, QC H1T 1C9, Canada
| | - Maxime Raison
- Department of Mechanical Engineering, Polytechnique Montréal, Montréal, QC H3T 1J4, Canada; (M.R.); (S.A.)
- Marie-Enfant Rehabilitation Center, Research Center of Ste-Justine University Hospital Center, Montreal, QC H1T 1C9, Canada
| | - Sofiane Achiche
- Department of Mechanical Engineering, Polytechnique Montréal, Montréal, QC H3T 1J4, Canada; (M.R.); (S.A.)
| |
Collapse
|
6
|
Longatelli V, Antonietti A, Biffi E, Diella E, D'Angelo MG, Rossini M, Molteni F, Bocciolone M, Pedrocchi A, Gandolla M. User-centred assistive SystEm for arm Functions in neUromuscuLar subjects (USEFUL): a randomized controlled study. J Neuroeng Rehabil 2021; 18:4. [PMID: 33407580 PMCID: PMC7789525 DOI: 10.1186/s12984-020-00794-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 12/01/2020] [Indexed: 12/16/2022] Open
Abstract
Background Upper limb assistive devices can compensate for muscular weakness and empower the user in the execution of daily activities. Multiple devices have been recently proposed but there is still a lack in the scientific comparison of their efficacy. Methods We conducted a cross-over multi-centric randomized controlled trial to assess the functional improvement at the upper limb level of two arms supports on 36 patients with muscular dystrophy. Participants tested a passive device (i.e., Wrex by Jaeco) and a semi-active solution for gravity compensation (i.e., Armon Ayura). We evaluated devices’ effectiveness with an externally-assessed scale (i.e., Performance of the Upper Limb-PUL-module), a self-perceived scale (i.e., Abilhand questionnaire), and a usability scale (i.e., System Usability Scale). Friedman’s test was used to assess significant functional gain for PUL module and Abilhand questionnaire. Moreover, PUL changes were compared by means of the Friedman’s test. Results Most of the patients improved upper limb function with the use of arm supports (median PUL scores increase of 1–3 points). However, the effectiveness of each device was related to the level of residual ability of the end-user. Slightly impaired patients maintained the same independence without and with assistive devices, even if they reported reduced muscular fatigue for both devices. Moderately impaired patients enhanced their arm functionality with both devices, and they obtained higher improvements with the semi-active one (median PUL scores increase of 9 points). Finally, severely impaired subjects benefited only from the semi-active device (median PUL scores increase of 12 points). Inadequate strength was recognized as a barrier to passive devices. The usability, measured by the System Usability Scale, was evaluated by end-users “good” (70/100 points) for the passive, and “excellent” (80/100 points) for the semi-active device. Conclusions This study demonstrated that assistive devices can improve the quality of life of people suffering from muscular dystrophy. The use of passive devices, despite being low cost and easy to use, shows limitations in the efficacy of the assistance to daily tasks, limiting the assistance to a predefined horizontal plane. The addition of one active degree of freedom improves efficacy and usability especially for medium to severe patients. Further investigations are needed to increase the evidence on the effect of arm supports on quality of life and diseases’ progression in subjects with degenerative disorders. Trial registration clinicaltrials.gov, NCT03127241, Registered 25th April 2017. The clinical trial was also registered as a post-market study at the Italian Ministry of Health.
Collapse
Affiliation(s)
- Valeria Longatelli
- NeuroEngineering And medical Robotics Laboratory, NearLab, Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Via Giuseppe Colombo 40, 20133, Milan, Italy
| | - Alberto Antonietti
- NeuroEngineering And medical Robotics Laboratory, NearLab, Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Via Giuseppe Colombo 40, 20133, Milan, Italy
| | - Emilia Biffi
- Scientific Institute IRCCS E. Medea, Via Don Luigi Monza 20, 23842, Bosisio Parini, Italy
| | - Eleonora Diella
- Scientific Institute IRCCS E. Medea, Via Don Luigi Monza 20, 23842, Bosisio Parini, Italy
| | - Maria Grazia D'Angelo
- Scientific Institute IRCCS E. Medea, Via Don Luigi Monza 20, 23842, Bosisio Parini, Italy
| | - Mauro Rossini
- Valduce Hospital, Villa Beretta Rehabilitation Center, Via Nazario Sauro 17, 23845, Costa Masnaga, Italy
| | - Franco Molteni
- Valduce Hospital, Villa Beretta Rehabilitation Center, Via Nazario Sauro 17, 23845, Costa Masnaga, Italy
| | - Marco Bocciolone
- Department of Mechanical Engineering, Politecnico di Milano, Via Giuseppe La Masa 1, 20156, Milan, Italy
| | - Alessandra Pedrocchi
- NeuroEngineering And medical Robotics Laboratory, NearLab, Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Via Giuseppe Colombo 40, 20133, Milan, Italy
| | - Marta Gandolla
- NeuroEngineering And medical Robotics Laboratory, NearLab, Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Via Giuseppe Colombo 40, 20133, Milan, Italy. .,Department of Mechanical Engineering, Politecnico di Milano, Via Giuseppe La Masa 1, 20156, Milan, Italy.
| |
Collapse
|
7
|
Cruz A, Callaway L, Randall M, Ryan M. Mobile arm supports in Duchenne muscular dystrophy: a pilot study of user experience and outcomes. Disabil Rehabil Assist Technol 2020; 16:880-889. [PMID: 32293211 DOI: 10.1080/17483107.2020.1749892] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
PURPOSE This pilot study examined whether two different types of non-powered mobile arm supports (MAS) enhanced upper limb function and independence with activities of daily living (ADLs) in people with Duchenne muscular dystrophy (DMD). METHOD A mixed methods cross-sectional design was used. Participants were four males with DMD, aged 16 to 20 years (M = 18.25 years). Two participants were current MAS users, and two had previously used MAS. To explore experiences of MAS use, semi-structured interviews were undertaken, then transcribed verbatim and analysed thematically. To measure the impact of MAS on arm function and ADLs, participants using MAS completed the Performance of the Upper Limb (PUL) and the DMD Upper Limb Patient Reported Outcome Measure with and without MAS. Participants no longer using MAS only completed the PUL without MAS. RESULTS MAS enhanced upper limb function and independence with ADLs in three of four participants. Eating and drinking was most often positively impacted by MAS. Access to informal support for MAS set-up, and ongoing input from a clinician or assistive technology (AT) supplier with MAS expertise, were important enablers to successful MAS use. Barriers to use included inadequate upper limb strength, interference of MAS with wheelchair controls, and AT funding delays. CONCLUSION MAS should be considered by individuals with DMD and clinicians working with them as the disease progresses and strength declines. Potential barriers to MAS use need to be addressed to ensure maximum utility. AT funding delays must also be minimized to avoid impact on outcomes of people with DMD.Implications for RehabilitationIndividuals with DMD, and clinicians working with them, may consider MAS to aid achievement of functional goals as the disease progresses and upper limb function declines.Both objective and subjective outcome measures should be used when evaluating the effectiveness of MAS.Consideration should be given to the potential interference of MAS with wheelchair controls and the availability of informal or paid supports (e.g., family, support workers, teachers) to aid MAS use.Efficient and timely funding of MAS is required, as delays may negatively impact outcomes for people with progressive neurological conditions, such as DMD.
Collapse
Affiliation(s)
- Ashlee Cruz
- The Royal Children's Hospital, Melbourne, Australia.,Department of Occupational Therapy, Monash University, Frankston, Australia
| | - Libby Callaway
- Department of Occupational Therapy, Monash University, Frankston, Australia.,Neuroskills Pty Ltd, Sandringham, Australia
| | - Melinda Randall
- The Royal Children's Hospital, Melbourne, Australia.,Murdoch Children's Research Institute, Melbourne, Australia
| | - Monique Ryan
- The Royal Children's Hospital, Melbourne, Australia.,Murdoch Children's Research Institute, Melbourne, Australia
| |
Collapse
|
8
|
Gandolla M, Antonietti A, Longatelli V, Pedrocchi A. The Effectiveness of Wearable Upper Limb Assistive Devices in Degenerative Neuromuscular Diseases: A Systematic Review and Meta-Analysis. Front Bioeng Biotechnol 2020; 7:450. [PMID: 32039171 PMCID: PMC6992540 DOI: 10.3389/fbioe.2019.00450] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Accepted: 12/18/2019] [Indexed: 12/18/2022] Open
Abstract
Background: This systematic review summarizes the current evidence about the effectiveness of wearable assistive technologies for upper limbs support during activities of daily living for individuals with neuromuscular diseases. Methods: Fourteen studies have been included in the meta-analysis, involving 184 participants. All included studies compared patients ability to perform functional tasks with and without assistive devices. Results: An overall effect size of 1.06 (95% CI = 0.76-1.36, p < 0.00001) was obtained, demonstrating that upper limbs assistive devices significantly improve the performance in activities of daily living in people with neuromuscular diseases. A significant interaction between studies evaluating functional improvement with externally-assessed outcome measures or self-perceived outcome measures has been detected. In particular, the effect size of the sub-group considering self-perceived scales was 1.38 (95% CI = 1.08-1.68), while the effect size of the other group was 0.77 (95% CI = 0.41-1.11), meaning that patients' perceived functional gain is often higher than the functional gain detectable through clinical scales. Conclusion: Overall, the quality of the evidence ranged from low to moderate, due to low number of studies and participants, limitations in the selection of participants and in the blindness of outcome assessors, and risk of publication bias. Significance: A large magnitude effect and a clear dose-response gradient were found, therefore, a strong recommendation, in favor of the use of assistive devices could be suggested.
Collapse
Affiliation(s)
- Marta Gandolla
- Nearlab@Lecco, Polo Territoriale di Lecco, Politecnico di Milano, Lecco, Italy
| | - Alberto Antonietti
- Nearlab, Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Valeria Longatelli
- Nearlab, Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Alessandra Pedrocchi
- Nearlab, Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| |
Collapse
|
9
|
Wang W, Qin L, Yuan X, Ming X, Sun T, Liu Y. Bionic control of exoskeleton robot based on motion intention for rehabilitation training. Adv Robot 2019. [DOI: 10.1080/01691864.2019.1621774] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- Wendong Wang
- School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an, People’s Republic of China
| | - Lei Qin
- School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an, People’s Republic of China
| | - Xiaoqing Yuan
- School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an, People’s Republic of China
| | - Xing Ming
- School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an, People’s Republic of China
| | - Tongsen Sun
- School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an, People’s Republic of China
| | - Yifan Liu
- School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an, People’s Republic of China
| |
Collapse
|
10
|
Lobo-Prat J, Nizamis K, Janssen MMHP, Keemink AQL, Veltink PH, Koopman BFJM, Stienen AHA. Comparison between sEMG and force as control interfaces to support planar arm movements in adults with Duchenne: a feasibility study. J Neuroeng Rehabil 2017; 14:73. [PMID: 28701169 PMCID: PMC5508565 DOI: 10.1186/s12984-017-0282-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2016] [Accepted: 06/26/2017] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Adults with Duchenne muscular dystrophy (DMD) can benefit from devices that actively support their arm function. A critical component of such devices is the control interface as it is responsible for the human-machine interaction. Our previous work indicated that surface electromyography (sEMG) and force-based control with active gravity and joint-stiffness compensation were feasible solutions for the support of elbow movements (one degree of freedom). In this paper, we extend the evaluation of sEMG- and force-based control interfaces to simultaneous and proportional control of planar arm movements (two degrees of freedom). METHODS Three men with DMD (18-23 years-old) with different levels of arm function (i.e. Brooke scores of 4, 5 and 6) performed a series of line-tracing tasks over a tabletop surface using an experimental active arm support. The arm movements were controlled using three control methods: sEMG-based control, force-based control with stiffness compensation (FSC), and force-based control with no compensation (FNC). The movement performance was evaluated in terms of percentage of task completion, tracing error, smoothness and speed. RESULTS For subject S1 (Brooke 4) FNC was the preferred method and performed better than FSC and sEMG. FNC was not usable for subject S2 (Brooke 5) and S3 (Brooke 6). Subject S2 presented significantly lower movement speed with sEMG than with FSC, yet he preferred sEMG since FSC was perceived to be too fatiguing. Subject S3 could not successfully use neither of the two force-based control methods, while with sEMG he could reach almost his entire workspace. CONCLUSIONS Movement performance and subjective preference of the three control methods differed with the level of arm function of the participants. Our results indicate that all three control methods have to be considered in real applications, as they present complementary advantages and disadvantages. The fact that the two weaker subjects (S2 and S3) experienced the force-based control interfaces as fatiguing suggests that sEMG-based control interfaces could be a better solution for adults with DMD. Yet force-based control interfaces can be a better alternative for those cases in which voluntary forces are higher than the stiffness forces of the arms.
Collapse
Affiliation(s)
- Joan Lobo-Prat
- Department of Biomechanical Engineering, University of Twente, Drienerlolaan 5, Enschede, 7522, NB, The Netherlands.
| | - Kostas Nizamis
- Department of Biomechanical Engineering, University of Twente, Drienerlolaan 5, Enschede, 7522, NB, The Netherlands
| | - Mariska M H P Janssen
- Department of Rehabilitation, Radboud University Medical Center, Reinier Postlaan 4, Nijmegen, 6500, HB, The Netherlands
| | - Arvid Q L Keemink
- Department of Biomechanical Engineering, University of Twente, Drienerlolaan 5, Enschede, 7522, NB, The Netherlands
| | - Peter H Veltink
- Department of Biomedical Signals and Systems, University of Twente, Drienerlolaan 5, Enschede, 7500, AE, The Netherlands
| | - Bart F J M Koopman
- Department of Biomechanical Engineering, University of Twente, Drienerlolaan 5, Enschede, 7522, NB, The Netherlands
| | - Arno H A Stienen
- Department of Biomechanical Engineering, University of Twente, Drienerlolaan 5, Enschede, 7522, NB, The Netherlands
- Department of Physical Therapy and Human Movement Sciences, Northwestern University, 645 N Michigan Ave Suite 1100, Chicago (IL), 60611, USA
| |
Collapse
|
11
|
Lobo-Prat J, Kooren PN, Janssen MMHP, Keemink AQL, Veltink PH, Stienen AHA, Koopman BFJM. Implementation of EMG- and Force-Based Control Interfaces in Active Elbow Supports for Men With Duchenne Muscular Dystrophy: A Feasibility Study. IEEE Trans Neural Syst Rehabil Eng 2016; 24:1179-1190. [DOI: 10.1109/tnsre.2016.2530762] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|