1
|
Rubin N, Hinson R, Saul K, Filer W, Hu X, Huang H(H. Modified motor unit properties in residual muscle following transtibial amputation. J Neural Eng 2024; 21:10.1088/1741-2552/ad1ac2. [PMID: 38176027 PMCID: PMC11214693 DOI: 10.1088/1741-2552/ad1ac2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 01/04/2024] [Indexed: 01/06/2024]
Abstract
Objective.Neural signals in residual muscles of amputated limbs are frequently decoded to control powered prostheses. Yet myoelectric controllers assume muscle activities of residual muscles are similar to that of intact muscles. This study sought to understand potential changes to motor unit (MU) properties after limb amputation.Approach.Six people with unilateral transtibial amputation were recruited. Surface electromyogram (EMG) of residual and intacttibialis anterior(TA) andgastrocnemius(GA) muscles were recorded while subjects traced profiles targeting up to 20% and 35% of maximum activation for each muscle (isometric for intact limbs). EMG was decomposed into groups of MU spike trains. MU recruitment thresholds, action potential amplitudes (MU size), and firing rates were correlated to model Henneman's size principle, the onion-skin phenomenon, and rate-size associations. Organization (correlation) and modulation (rates of change) of relations were compared between intact and residual muscles.Main results.The residual TA exhibited significantly lower correlation and flatter slopes in the size principle and onion-skin, and each outcome covaried between the MU relations. The residual GA was unaffected for most subjects. Subjects trained prior with myoelectric prostheses had minimally affected slopes in the TA. Rate-size association correlations were preserved, but both residual muscles exhibited flatter decay rates.Significance.We showed peripheral neuromuscular damage also leads to spinal-level functional reorganizations. Our findings suggest models of MU recruitment and discharge patterns for residual muscle EMG generation need reparameterization to account for disturbances observed. In the future, tracking MU pool adaptations may also provide a biomarker of neuromuscular control to aid training with myoelectric prostheses.
Collapse
Affiliation(s)
- Noah Rubin
- UNC/NC State Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, United States of America
| | - Robert Hinson
- UNC/NC State Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, United States of America
- UNC/NC State Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, United States of America
- School of Medicine, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, United States of America
| | - Katherine Saul
- Department of Mechanical & Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, United States of America
| | - William Filer
- School of Medicine, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, United States of America
| | - Xiaogang Hu
- Department of Mechanical Engineering, Pennsylvania State University, University Park, PA 16802, United States of America
| | - He (Helen) Huang
- UNC/NC State Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, United States of America
| |
Collapse
|
2
|
Johansson R, Jensen L, Barnett CT, Rusaw DF. Quantitative methods used to evaluate balance, postural control, and the fear of falling in lower limb prosthesis users: A systematic review. Prosthet Orthot Int 2023; 47:586-598. [PMID: 37318276 DOI: 10.1097/pxr.0000000000000250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Accepted: 04/23/2023] [Indexed: 06/16/2023]
Abstract
Problems with balance, postural control, and fear of falling are highly prevalent in lower limb prosthesis users, with much research conducted to understand these issues. The variety of tools used to assess these concepts presents a challenge when interpreting research outcomes. This systematic review aimed to provide a synthesis of quantifiable methods used in the evaluation of balance, postural control, and fear of falling in lower limb prosthesis users with an amputation level at or proximal to the ankle joint. A systematic search was conducted in CINAHL, Medline, AMED, Cochrane, AgeLine, Scopus, Web of Science, Proquest, PsycINFO, PsycArticles, and PubPsych databases followed by additional manual searching via reference lists in the reviewed articles databases. Included articles used quantitative measure of balance or postural control as one of the dependent variables, lower limb prosthesis users as a sample group, and were published in a peer-reviewed journal in English. Relevant assessment questions were created by the investigators to rate the assessment methods used in the individual studies. Descriptive and summary statistics are used to synthesize the results. The search yielded (n = 187) articles assessing balance or postural control (n = 5487 persons in total) and (n = 66) articles assessing fear of falling or balance confidence (n = 7325 persons in total). The most used test to measure balance was the Berg Balance Scale and the most used test to measure fear of falling was the Activities-specific Balance Confidence scale. A large number of studies did not present if the chosen methods were valid and reliable for the lower limb prosthesis users. Among study limitations, small sample size was common.
Collapse
Affiliation(s)
- Robin Johansson
- School of Health and Welfare, Jönköping University, Jönköping, Sweden
| | - Louise Jensen
- School of Health and Welfare, Jönköping University, Jönköping, Sweden
- Southern Älvsborg Hospital, Borås, Sweden
| | - Cleveland T Barnett
- School of Science and Technology, Nottingham Trent University, Nottingham, United Kingdom
| | - David F Rusaw
- School of Health and Welfare, Jönköping University, Jönköping, Sweden
| |
Collapse
|
3
|
Fleming A, Liu W, Huang HH. Neural prosthesis control restores near-normative neuromechanics in standing postural control. Sci Robot 2023; 8:eadf5758. [PMID: 37851818 PMCID: PMC10882517 DOI: 10.1126/scirobotics.adf5758] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Accepted: 09/20/2023] [Indexed: 10/20/2023]
Abstract
Current lower-limb prostheses do not provide active assistance in postural control tasks to maintain the user's balance, particularly in situations of perturbation. In this study, we aimed to address this missing function by enabling neural control of robotic lower-limb prostheses. Specifically, electromyographic (EMG) signals (amplified neural control signals) recorded from antagonistic residual ankle muscles were used to drive a robotic prosthetic ankle directly and continuously. Participants with transtibial amputation were recruited and trained in using the EMG-driven robotic ankle. We studied how using the EMG-controlled ankle affected the participants' anticipatory and compensatory postural control strategies and stability under expected perturbations compared with using their daily passive devices. We investigated the similarity of neuromuscular coordination (by analyzing motor modules) of the participants, using either device in a postural sway task, to that of able-bodied controls. Results showed that, compared with their passive prosthesis, the EMG-controlled prosthesis enabled participants to use near-normative postural control strategies, as evidenced by improved between-limb symmetry in intact-prosthetic center-of-pressure and joint angle excursions. Participants substantially improved postural stability, as evidenced by a reduction in steps or falls using the EMG-controlled prosthetic ankle. Furthermore, after relearning to use residual ankle muscles to drive the robotic ankle in postural control, nearly all participants' motor module structure shifted toward that observed in individuals without limb amputations. Here, we have demonstrated the potential benefit of direct EMG control of robotic lower limb prostheses to restore normative postural control strategies (both neural and biomechanical) toward enhancing standing postural stability in amputee users.
Collapse
Affiliation(s)
- Aaron Fleming
- Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
| | - Wentao Liu
- Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
| | - He Helen Huang
- Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
| |
Collapse
|
4
|
Ahkami B, Ahmed K, Thesleff A, Hargrove L, Ortiz-Catalan M. Electromyography-Based Control of Lower Limb Prostheses: A Systematic Review. IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS 2023; 5:547-562. [PMID: 37655190 PMCID: PMC10470657 DOI: 10.1109/tmrb.2023.3282325] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
Abstract
Most amputations occur in lower limbs and despite improvements in prosthetic technology, no commercially available prosthetic leg uses electromyography (EMG) information as an input for control. Efforts to integrate EMG signals as part of the control strategy have increased in the last decade. In this systematic review, we summarize the research in the field of lower limb prosthetic control using EMG. Four different online databases were searched until June 2022: Web of Science, Scopus, PubMed, and Science Direct. We included articles that reported systems for controlling a prosthetic leg (with an ankle and/or knee actuator) by decoding gait intent using EMG signals alone or in combination with other sensors. A total of 1,331 papers were initially assessed and 121 were finally included in this systematic review. The literature showed that despite the burgeoning interest in research, controlling a leg prosthesis using EMG signals remains challenging. Specifically, regarding EMG signal quality and stability, electrode placement, prosthetic hardware, and control algorithms, all of which need to be more robust for everyday use. In the studies that were investigated, large variations were found between the control methodologies, type of research participant, recording protocols, assessments, and prosthetic hardware.
Collapse
Affiliation(s)
- Bahareh Ahkami
- Center for Bionics and Pain Research, 43130 Mölndal, Sweden, and also with the Department of Electrical Engineering, Chalmers University of Technology, 41296 Gothenburg, Sweden
| | - Kirstin Ahmed
- Center for Bionics and Pain Research, 43130 Mölndal, Sweden, and also with the Department of Electrical Engineering, Chalmers University of Technology, 41296 Gothenburg, Sweden
| | - Alexander Thesleff
- Center for Bionics and Pain Research, 43130 Mölndal, Sweden, also with the Department of Electrical Engineering, Chalmers University of Technology, 41296 Gothenburg, Sweden, and also with Integrum AB, 43153 Molndal, Sweden
| | - Levi Hargrove
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL 60611 USA, and also with the Regenstein Foundation Center for Bionic Medicine, Shirley Ryan AbilityLab, Chicago, IL 60611 USA
| | - Max Ortiz-Catalan
- Center for Bionics and Pain Research, 43130 Mölndal, Sweden, also with the Department of Electrical Engineering, Chalmers University of Technology, 41296 Gothenburg, Sweden, also with the Operational Area 3, Sahlgrenska University Hospital, 41345 Gothenburg, Sweden, and also with Bionics Institute, Melbourne, VIC 3002, Australia
| |
Collapse
|
5
|
Cimolato A, Driessen JJM, Mattos LS, De Momi E, Laffranchi M, De Michieli L. EMG-driven control in lower limb prostheses: a topic-based systematic review. J Neuroeng Rehabil 2022; 19:43. [PMID: 35526003 PMCID: PMC9077893 DOI: 10.1186/s12984-022-01019-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Accepted: 04/13/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The inability of users to directly and intuitively control their state-of-the-art commercial prosthesis contributes to a low device acceptance rate. Since Electromyography (EMG)-based control has the potential to address those inabilities, research has flourished on investigating its incorporation in microprocessor-controlled lower limb prostheses (MLLPs). However, despite the proposed benefits of doing so, there is no clear explanation regarding the absence of a commercial product, in contrast to their upper limb counterparts. OBJECTIVE AND METHODOLOGIES This manuscript aims to provide a comparative overview of EMG-driven control methods for MLLPs, to identify their prospects and limitations, and to formulate suggestions on future research and development. This is done by systematically reviewing academical studies on EMG MLLPs. In particular, this review is structured by considering four major topics: (1) type of neuro-control, which discusses methods that allow the nervous system to control prosthetic devices through the muscles; (2) type of EMG-driven controllers, which defines the different classes of EMG controllers proposed in the literature; (3) type of neural input and processing, which describes how EMG-driven controllers are implemented; (4) type of performance assessment, which reports the performance of the current state of the art controllers. RESULTS AND CONCLUSIONS The obtained results show that the lack of quantitative and standardized measures hinders the possibility to analytically compare the performances of different EMG-driven controllers. In relation to this issue, the real efficacy of EMG-driven controllers for MLLPs have yet to be validated. Nevertheless, in anticipation of the development of a standardized approach for validating EMG MLLPs, the literature suggests that combining multiple neuro-controller types has the potential to develop a more seamless and reliable EMG-driven control. This solution has the promise to retain the high performance of the currently employed non-EMG-driven controllers for rhythmic activities such as walking, whilst improving the performance of volitional activities such as task switching or non-repetitive movements. Although EMG-driven controllers suffer from many drawbacks, such as high sensitivity to noise, recent progress in invasive neural interfaces for prosthetic control (bionics) will allow to build a more reliable connection between the user and the MLLPs. Therefore, advancements in powered MLLPs with integrated EMG-driven control have the potential to strongly reduce the effects of psychosomatic conditions and musculoskeletal degenerative pathologies that are currently affecting lower limb amputees.
Collapse
Affiliation(s)
- Andrea Cimolato
- Rehab Technologies Lab, Fondazione Istituto Italiano di Tecnologia, Via Morego, 30, 16163 Genova, Italy
- Department of Electronics, Information and Bioengineering (DEIB), Neuroengineering and Medical Robotics Laboratory, Politecnico di Milano, Building 32.2, Via Giuseppe Colombo, 20133 Milan, Italy
| | - Josephus J. M. Driessen
- Rehab Technologies Lab, Fondazione Istituto Italiano di Tecnologia, Via Morego, 30, 16163 Genova, Italy
| | - Leonardo S. Mattos
- Department of Advanced Robotics, Fondazione Istituto Italiano di Tecnologia, Via Morego, 30, 16163 Genova, Italy
| | - Elena De Momi
- Department of Electronics, Information and Bioengineering (DEIB), Neuroengineering and Medical Robotics Laboratory, Politecnico di Milano, Building 32.2, Via Giuseppe Colombo, 20133 Milan, Italy
| | - Matteo Laffranchi
- Rehab Technologies Lab, Fondazione Istituto Italiano di Tecnologia, Via Morego, 30, 16163 Genova, Italy
| | - Lorenzo De Michieli
- Rehab Technologies Lab, Fondazione Istituto Italiano di Tecnologia, Via Morego, 30, 16163 Genova, Italy
| |
Collapse
|
6
|
Huh SU. Optimization of immune receptor-related hypersensitive cell death response assay using agrobacterium-mediated transient expression in tobacco plants. PLANT METHODS 2022; 18:57. [PMID: 35501866 PMCID: PMC9063123 DOI: 10.1186/s13007-022-00893-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Accepted: 04/21/2022] [Indexed: 05/10/2023]
Abstract
BACKGROUND The study of the regulatory mechanisms of evolutionarily conserved Nucleotide-binding leucine-rich repeat (NLR) resistance (R) proteins in animals and plants is of increasing importance due to understanding basic immunity and the value of various crop engineering applications of NLR immune receptors. The importance of temperature is also emerging when applying NLR to crops responding to global climate change. In particular, studies of pathogen effector recognition and autoimmune activity of NLRs in plants can quickly and easily determine their function in tobacco using agro-mediated transient assay. However, there are conditions that should not be overlooked in these cell death-related assays in tobacco. RESULTS Environmental conditions play an important role in the immune response of plants. The system used in this study was to establish conditions for optimal hypertensive response (HR) cell death analysis by using the paired NLR RPS4/RRS1 autoimmune and AvrRps4 effector recognition system. The most suitable greenhouse temperature for growing plants was fixed at 22 °C. In this study, RPS4/RRS1-mediated autoimmune activity, RPS4 TIR domain-dependent cell death, and RPS4/RRS1-mediated HR cell death upon AvrRps4 perception significantly inhibited under conditions of 65% humidity. The HR is strongly activated when the humidity is below 10%. Besides, the leaf position of tobacco is important for HR cell death. Position #4 of the leaf from the top in 4-5 weeks old tobacco plants showed the most effective HR cell death. CONCLUSIONS As whole genome sequencing (WGS) or resistance gene enrichment sequencing (RenSeq) of various crops continues, different types of NLRs and their functions will be studied. At this time, if we optimize the conditions for evaluating NLR-mediated HR cell death, it will help to more accurately identify the function of NLRs. In addition, it will be possible to contribute to crop development in response to global climate change through NLR engineering.
Collapse
Affiliation(s)
- Sung Un Huh
- Department of Biological Science, Kunsan National University, Gunsan, 54150, Republic of Korea.
| |
Collapse
|
7
|
Direct continuous electromyographic control of a powered prosthetic ankle for improved postural control after guided physical training: A case study. ACTA ACUST UNITED AC 2021; 2. [PMID: 34532707 PMCID: PMC8443146 DOI: 10.1017/wtc.2021.2] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Despite the promise of powered lower limb prostheses, existing controllers do not assist many daily activities that require continuous control of prosthetic joints according to human states and environments. The objective of this case study was to investigate the feasibility of direct, continuous electromyographic (dEMG) control of a powered ankle prosthesis, combined with physical therapist-guided training, for improved standing postural control in an individual with transtibial amputation. Specifically, EMG signals of the residual antagonistic muscles (i.e. lateral gastrocnemius and tibialis anterior) were used to proportionally drive pneumatical artificial muscles to move a prosthetic ankle. Clinical-based activities were used in the training and evaluation protocol of the control paradigm. We quantified the EMG signals in the bilateral shank muscles as well as measures of postural control and stability. Compared to the participant's daily passive prosthesis, the dEMG-controlled ankle, combined with the training, yielded improved clinical balance scores and reduced compensation from intact joints. Cross-correlation coefficient of bilateral center of pressure excursions, a metric for quantifying standing postural control, increased to .83(±.07) when using dEMG ankle control (passive device: .39(±.29)). We observed synchronized activation of homologous muscles, rapid improvement in performance on the first day of the training for load transfer tasks, and further improvement in performance across training days (p = .006). This case study showed the feasibility of this dEMG control paradigm of a powered prosthetic ankle to assist postural control. This study lays the foundation for future study to extend these results through the inclusion of more participants and activities.
Collapse
|
8
|
Fleming A, Stafford N, Huang S, Hu X, Ferris DP, Huang H(H. Myoelectric control of robotic lower limb prostheses: a review of electromyography interfaces, control paradigms, challenges and future directions. J Neural Eng 2021; 18:10.1088/1741-2552/ac1176. [PMID: 34229307 PMCID: PMC8694273 DOI: 10.1088/1741-2552/ac1176] [Citation(s) in RCA: 43] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Accepted: 07/06/2021] [Indexed: 11/16/2022]
Abstract
Objective.Advanced robotic lower limb prostheses are mainly controlled autonomously. Although the existing control can assist cyclic movements during locomotion of amputee users, the function of these modern devices is still limited due to the lack of neuromuscular control (i.e. control based on human efferent neural signals from the central nervous system to peripheral muscles for movement production). Neuromuscular control signals can be recorded from muscles, called electromyographic (EMG) or myoelectric signals. In fact, using EMG signals for robotic lower limb prostheses control has been an emerging research topic in the field for the past decade to address novel prosthesis functionality and adaptability to different environments and task contexts. The objective of this paper is to review robotic lower limb Prosthesis control via EMG signals recorded from residual muscles in individuals with lower limb amputations.Approach.We performed a literature review on surgical techniques for enhanced EMG interfaces, EMG sensors, decoding algorithms, and control paradigms for robotic lower limb prostheses.Main results.This review highlights the promise of EMG control for enabling new functionalities in robotic lower limb prostheses, as well as the existing challenges, knowledge gaps, and opportunities on this research topic from human motor control and clinical practice perspectives.Significance.This review may guide the future collaborations among researchers in neuromechanics, neural engineering, assistive technologies, and amputee clinics in order to build and translate true bionic lower limbs to individuals with lower limb amputations for improved motor function.
Collapse
Affiliation(s)
- Aaron Fleming
- Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, United States of America
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, United States of America
- Equal contribution as the first author
| | - Nicole Stafford
- Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL 32611, United States of America
- Equal contribution as the first author
| | - Stephanie Huang
- Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, United States of America
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, United States of America
| | - Xiaogang Hu
- Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, United States of America
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, United States of America
| | - Daniel P Ferris
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611, United States of America
| | - He (Helen) Huang
- Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, United States of America
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, United States of America
| |
Collapse
|
9
|
Rusaw DF, Alinder R, Edholm S, Hallstedt KLL, Runesson J, Barnett CT. Development of a theoretical model for upright postural control in lower limb prosthesis users. Sci Rep 2021; 11:8263. [PMID: 33859266 PMCID: PMC8050312 DOI: 10.1038/s41598-021-87657-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Accepted: 04/01/2021] [Indexed: 11/24/2022] Open
Abstract
Methods used to assess quiet standing in unilateral prosthesis users often assume validity of an inverted pendulum model despite this being shown as invalid in some instances. The aim of the current study was to evaluate the validity of a proposed unilaterally-constrained pin-controller model in explaining postural control in unilateral prosthesis users. Prosthesis users were contrasted against the theoretical model as were able-bodied controls that stood on a platform which unilaterally constrained movement of the CoP. All participants completed bouts of quiet standing with eyes open, eyes closed and with feedback on inter-limb weight bearing asymmetry. Correlation coefficients were used to infer inverted pendulum behavior in both the anteroposterior and mediolateral directions and were derived from both kinematic (body attached markers) and kinetic (centre of pressure) experimental data. Larger, negative correlation coefficients reflected better model adherence, whilst low or no correlation reflected poorer model adherence. Inverted pendulum behavior derived from kinematic data, indicated coefficients of high magnitude in both mediolateral (all cases range 0.71–0.78) and anteroposterior (0.88–0.91) directions, irrespective of groups. Inverted pendulum behavior derived from kinetic data in the anteroposterior direction indicated validity of the model with large negative coefficients associated with the unconstrained/intact limbs (prosthesis users: − 0.45 to − 0.65, control group: − 0.43 to − 0.72), small coefficients in constrained/prosthetic limbs (prosthesis users: − 0.02 to 0.07, control group: 0.13–0.26) and large negative coefficients in combined conditions (prosthesis users: − 0.36 to − 0.56, control group: − 0.71 to − 0.82). For the mediolateral direction, coefficients were negligible for individual limbs (0.03–0.17) and moderate to large negative correlations, irrespective of group (− 0.31 to − 0.73). Data suggested both prosthesis users’ and able-bodied individuals’ postural control conforms well to that predicted by a unilaterally-constrained pin-controller model, which has implications for the fundamental control of posture in transtibial prosthesis users.
Collapse
Affiliation(s)
- David F Rusaw
- School of Health and Welfare, Jönköping University, Box 1026, 55111, Jönköping, Sweden.
| | - Rasmus Alinder
- School of Health and Welfare, Jönköping University, Box 1026, 55111, Jönköping, Sweden
| | - Sigurd Edholm
- School of Health and Welfare, Jönköping University, Box 1026, 55111, Jönköping, Sweden
| | - Karin L L Hallstedt
- School of Health and Welfare, Jönköping University, Box 1026, 55111, Jönköping, Sweden
| | - Jessika Runesson
- School of Health and Welfare, Jönköping University, Box 1026, 55111, Jönköping, Sweden
| | - Cleveland T Barnett
- School of Science and Technology, Nottingham Trent University, Nottingham, UK
| |
Collapse
|
10
|
Chen L, Liu X, Xuan B, Zhang J, Liu Z, Zhang Y. Selection of EMG Sensors Based on Motion Coordinated Analysis. SENSORS 2021; 21:s21041147. [PMID: 33562131 PMCID: PMC7915866 DOI: 10.3390/s21041147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Revised: 02/01/2021] [Accepted: 02/03/2021] [Indexed: 11/16/2022]
Abstract
The intelligent prosthesis driven by electromyography (EMG) signal provides a solution for the movement of the disabled. The proper position of EMG sensors can improve the prosthesis's motion recognition ability. To exert the amputee's action-oriented ability and the prosthesis' control ability, the EMG spatial distribution and internal connection of the prosthetic wearer is analyzed in three kinds of movement conditions: appropriate angle, excessive angle, and angle too small. Firstly, the correlation characteristics between the EMG channels are analyzed by mutual information to construct a muscle functional network. Secondly, the network's features of different movement conditions are analyzed by calculating the characteristic of nodes and evaluating the importance of nodes. Finally, the convergent cross-mapping method is applied to construct a directed network, and the critical muscle groups which can reflect the user's movement intention are determined. Experiment shows that this method can accurately determine the EMG location and simplify the distribution of EMG sensors inside the prosthetic socket. The network characteristics of key muscle groups can distinguish different movements effectively and provide a new strategy for decoding the relationship between limb nerve control and body movement.
Collapse
Affiliation(s)
- Lingling Chen
- School of Artificial Intelligence and Data Science, Hebei University of Technology, Tianjin 300131, China; (L.C.); (X.L.); (Z.L.); (Y.Z.)
- Engineering Research Center of Intelligent Rehabilitation Device and Detection Technology, Ministry of Education, Tianjin 300131, China
| | - Xiaotian Liu
- School of Artificial Intelligence and Data Science, Hebei University of Technology, Tianjin 300131, China; (L.C.); (X.L.); (Z.L.); (Y.Z.)
| | - Bokai Xuan
- School of Artificial Intelligence and Data Science, Hebei University of Technology, Tianjin 300131, China; (L.C.); (X.L.); (Z.L.); (Y.Z.)
- Correspondence: ; Tel.: +86-1382-155-7991
| | - Jie Zhang
- School of Chemical Engineering and Advanced Materials, Newcastle University, Newcastle upon Tyne NE1 7RU, UK;
| | - Zuojun Liu
- School of Artificial Intelligence and Data Science, Hebei University of Technology, Tianjin 300131, China; (L.C.); (X.L.); (Z.L.); (Y.Z.)
- Engineering Research Center of Intelligent Rehabilitation Device and Detection Technology, Ministry of Education, Tianjin 300131, China
| | - Yan Zhang
- School of Artificial Intelligence and Data Science, Hebei University of Technology, Tianjin 300131, China; (L.C.); (X.L.); (Z.L.); (Y.Z.)
| |
Collapse
|