1
|
Lora-Millan JS, Sanchez-Cuesta FJ, Romero JP, Moreno JC, Rocon E. Robotic exoskeleton embodiment in post-stroke hemiparetic patients: an experimental study about the integration of the assistance provided by the REFLEX knee exoskeleton. Sci Rep 2023; 13:22908. [PMID: 38129592 PMCID: PMC10739721 DOI: 10.1038/s41598-023-50387-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 12/19/2023] [Indexed: 12/23/2023] Open
Abstract
Hemiparetic gait is the most common motor-disorder after stroke and, in spite of rehabilitation efforts, it is persistent in 50% of community dwelling stroke-survivors. Robotic exoskeletons have been proposed as assistive devices to support impaired joints. An example of these devices is the REFLEX knee exoskeleton, which assists the gait of hemiparetic subjects and whose action seems to be properly embodied by stroke survivors, who were able to adapt the motion of their non-assisted limbs and, therefore, reduce their compensation mechanisms. This paper presents an experimental validation carried out to deepen into the effects of REFLEX's assistance in hemiparetic subjects. Special attention was paid to the effect produced in the muscular activity as a metric to evaluate the embodiment of this technology. Significant differences were obtained at the subject level due to the assistance; however, the high dispersion of the measured outcomes avoided extracting global effects at the group level. These results highlight the need of individually tailoring the action of the robot to the individual needs of each patient to maximize the beneficial outcomes. Extra research effort should be done to elucidate the neural mechanisms involved in the embodiment of external devices by stroke survivors.
Collapse
Affiliation(s)
| | - Francisco José Sanchez-Cuesta
- Facultad de Ciencias Experimentales, Universidad Francisco de Vitoria, Pozuelo de Alarcón, Madrid, Spain
- Brain Injury and Movement Disorders Neurorehabilitation Group (GINDAT), Institute of Life Sciences, Francisco de Vitoria University, Pozuelo de Alarcón, Madrid, Spain
| | - Juan Pablo Romero
- Facultad de Ciencias Experimentales, Universidad Francisco de Vitoria, Pozuelo de Alarcón, Madrid, Spain
- Brain Injury and Movement Disorders Neurorehabilitation Group (GINDAT), Institute of Life Sciences, Francisco de Vitoria University, Pozuelo de Alarcón, Madrid, Spain
- Brain Damage Unit, Hospital Beata María Ana, Madrid, Spain
| | - Juan C Moreno
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Madrid, Spain
| | - Eduardo Rocon
- Centro de Automática y Robótica, Spanish National Research Council (CSIC), Madrid, Spain
| |
Collapse
|
2
|
Shin W, Nam D, Ahn B, Kim SJ, Lee DY, Kwon S, Kim J. Ankle dorsiflexion assistance of patients with foot drop using a powered ankle-foot orthosis to improve the gait asymmetry. J Neuroeng Rehabil 2023; 20:140. [PMID: 37864265 PMCID: PMC10589991 DOI: 10.1186/s12984-023-01261-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Accepted: 10/02/2023] [Indexed: 10/22/2023] Open
Abstract
BACKGROUND Foot drop is a neuromuscular disorder that causes abnormal gait patterns. This study developed a pneumatically powered ankle-foot orthosis (AFO) to improve the gait patterns of patients with foot drop. We hypothesized that providing unilateral ankle dorsiflexion assistance during the swing phase would improve the kinematics and spatiotemporal gait parameters of such patients. Accordingly, this study aims to examine the efficacy of the proposed assistance system using a strategy for joint kinematics and spatiotemporal gait parameters (stride length, swing velocity, and stance phase ratio). The analysis results are expected to provide knowledge for better design and control of AFOs in patients with foot drop. METHOD Ten foot drop patients with hemiparesis (54.8 y ± 14.1 y) were fitted with a custom AFO with an adjustable calf brace and portable air compressor for ankle dorsiflexion assistance in the gait cycle during the swing phase. All subjects walked under two different conditions without extensive practice: (1) barefoot and (2) wearing a powered AFO. Under each condition, the patients walked back and forth on a 9-m track with ten laps of level ground under the supervision of licensed physical therapists. The lower-limb joint and trunk kinematics were acquired using 12 motion-capture cameras. RESULTS We found that kinematic asymmetry decreased in the three lower-limb joints after ankle dorsiflexion assistance during the swing phase. The average ankle-joint angle increased after using the AFO during the entire gait cycle. Similarly, the knee-joint angle showed a slight increase while using the AFO, leading to a significantly decreased standard deviation within patients. Conversely, the hip-joint angle showed no significant improvements with assistance. While several patients exhibited noticeably lower levels of asymmetry, no significant changes were observed in the average asymmetry of the swing velocity difference between the affected and unaffected sides while using the AFO. CONCLUSION We experimentally validated that ankle dorsiflexion assistance during the swing phase temporarily improves gait asymmetry in foot-drop patients. The experimental results also prove the efficacy of the developed AFO for gait assistance in foot-drop patients.
Collapse
Affiliation(s)
- Wonseok Shin
- AI·Robotics R&D Group, Korea Institute of Industrial Technology, Ansan, 15588, Republic of Korea
| | - Dongwoo Nam
- AI·Robotics R&D Group, Korea Institute of Industrial Technology, Ansan, 15588, Republic of Korea
- School of Korea Institute of Industry Technology, Robotics and Virtual Engineering, University of Science and Technology, Ansan, 15588, Republic of Korea
| | - Bummo Ahn
- AI·Robotics R&D Group, Korea Institute of Industrial Technology, Ansan, 15588, Republic of Korea
- School of Korea Institute of Industry Technology, Robotics and Virtual Engineering, University of Science and Technology, Ansan, 15588, Republic of Korea
| | - Sangjoon J Kim
- Henry Samueli School of Engineering Department of Mechanical and Aerospace Engineering, University of California, Irvine, 92697, USA
| | - Dong Yeon Lee
- Department of Orthopedic Surgery, Seoul National University Hospital, Seoul, 03080, Republic of Korea
| | - Suncheol Kwon
- AI·Robotics R&D Group, Korea Institute of Industrial Technology, Ansan, 15588, Republic of Korea.
| | - Jung Kim
- Department of Mechanical Engineing, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea.
| |
Collapse
|
3
|
Wang J, Shu J, Su Y, Hu C, Yeung LF, Li Z, Tong RKY. A portable AFO solution for pneumatic actuator with cable tendon mechanism to assist ankle dorsiflexion. Front Bioeng Biotechnol 2023; 11:1227327. [PMID: 37929198 PMCID: PMC10621736 DOI: 10.3389/fbioe.2023.1227327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 10/06/2023] [Indexed: 11/07/2023] Open
Abstract
The limited portability of pneumatic pumps presents a challenge for ankle-foot orthosis actuated by pneumatic actuators. The high-pressure requirements and time delay responses of pneumatic actuators necessitate a powerful and large pump, which renders the entire device heavy and inconvenient to carry. In this paper, we propose and validate a concept that enhances portability by employing a slack cable tendon mechanism. By managing slack tension properly, the time delay response problem of pneumatic actuators is eliminated through early triggering, and the system can be effectively controlled to generate the desired force for dorsiflexion assistance. The current portable integration of the system weighs approximately 1.6 kg, with distribution of 0.5 kg actuation part on the shank and 1.1 kg power system on the waist, excluding the battery. A mathematical model is developed to determine the proper triggering time and volumetric flow rate requirements for pump selection. To evaluate the performance of this actuation system and mathematical model, the artificial muscle's response time and real volumetric flow rate were preliminarily tested with different portable pumps on a healthy participant during treadmill walking at various speeds ranging from 0.5 m/s to 1.75 m/s. Two small pumps, specifically VN-C1 (5.36 L/min, 300 g) and VN-C4 (9.71L/min, 550 g), meet our design criteria, and then tested on three healthy subjects walking at normal speeds of 1 m/s and 1.5 m/s. The kinematic and electromyographic results demonstrate that the device can facilitate ankle dorsiflexion with a portable pump (300-500 g), generating sufficient force to lift up the foot segment, and reducing muscle activity responsible for ankle dorsiflexion during the swing phase by 8% and 10% at normal speeds of 1 m/s and 1.5 m/s respectively. This portable ankle robot, equipped with a compact pump weighing approximately 1.6 kg, holds significant potential for assisting individuals with lower limb weakness in walking, both within their homes and in clinical settings.
Collapse
Affiliation(s)
- Junming Wang
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong SAR, China
| | - Jing Shu
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong SAR, China
| | - Yujie Su
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong SAR, China
| | - Chengpeng Hu
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong SAR, China
| | - Ling-Fung Yeung
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong SAR, China
| | - Zheng Li
- Department of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong SAR, China
| | - Raymond Kai-Yu Tong
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong SAR, China
| |
Collapse
|
4
|
Lora-Millan JS, Nabipour M, van Asseldonk E, Bayón C. Advances on mechanical designs for assistive ankle-foot orthoses. Front Bioeng Biotechnol 2023; 11:1188685. [PMID: 37485319 PMCID: PMC10361304 DOI: 10.3389/fbioe.2023.1188685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 06/27/2023] [Indexed: 07/25/2023] Open
Abstract
Assistive ankle-foot orthoses (AAFOs) are powerful solutions to assist or rehabilitate gait on humans. Existing AAFO technologies include passive, quasi-passive, and active principles to provide assistance to the users, and their mechanical configuration and control depend on the eventual support they aim for within the gait pattern. In this research we analyze the state-of-the-art of AAFO and classify the different approaches into clusters, describing their basis and working principles. Additionally, we reviewed the purpose and experimental validation of the devices, providing the reader with a better view of the technology readiness level. Finally, the reviewed designs, limitations, and future steps in the field are summarized and discussed.
Collapse
Affiliation(s)
| | - Mahdi Nabipour
- Department of Biomechanical Engineering, University of Twente, Enschede, Netherlands
| | - Edwin van Asseldonk
- Department of Biomechanical Engineering, University of Twente, Enschede, Netherlands
| | - Cristina Bayón
- Department of Biomechanical Engineering, University of Twente, Enschede, Netherlands
| |
Collapse
|
5
|
Kim Y, Cohen E. Combining transcutaneous interferential-current for nerve inhibition with a robotic assistant device for increasing ankle dorsiflexion in walking. Gait Posture 2023; 102:205-209. [PMID: 37043990 DOI: 10.1016/j.gaitpost.2023.04.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 03/27/2023] [Accepted: 04/05/2023] [Indexed: 04/14/2023]
Abstract
BACKGROUND A kilohertz-frequency alternating current transcutaneously applied was introduced as a novel neuromodulation technology for nerve inhibition innervating antagonist muscles. Combining this electrical nerve inhibition with a robotic assistance device has been proposed but not investigated. RESEARCH QUESTION This study aimed to demonstrate the effect of combining electrical nerve inhibition with a wearable robotic device on increasing ankle dorsiflexion during walking. We hypothesized that the wearable robotic device would elicit a greater ankle dorsiflexion angle with the same force in walking by applying the transcutaneous interferential-current nerve inhibition (TINI) technique to the tibial nerve. METHODS Eleven healthy young adults performed three experimental conditions. The ankle assistance (AA) condition was walking while wearing an ankle device with operating dorsiflexion assistance during pre-swing and swing phases. For the ankle assistance with electrical stimulation (AE) condition, TINI on the tibial nerve was additionally applied from the AA condition. In the ankle non-assistance (AN) condition, participants wore the device, but assistance was not provided. The joint angles during walking were measured and digitized through a motion analysis system. RESULTS During a gait cycle, immediate changes in ankle joint motions were observed in the sagittal plane. In the pre-swing phase, ankle dorsiflexion angle was significantly greater in AE condition than AA and AN. There was no significant difference in joint angle between AA and AN. SIGNIFICANCE This study demonstrates the effectiveness of combining TINI with a wearable robotic ankle device in increasing dorsiflexion angle during the pre-swing phase. This finding provides the feasibility of using TINI as a neuromodulation technique for assisting functional movement in human walking.
Collapse
Affiliation(s)
- Yushin Kim
- Department of Sports Rehabilitation, Cheongju University, Cheongju, South Korea.
| | - Ezra Cohen
- Division of Pediatric Rheumatology, Boston University; Division of Immunology, Boston Children's Hospital, Boston, MA, United States
| |
Collapse
|
6
|
de Miguel-Fernández J, Lobo-Prat J, Prinsen E, Font-Llagunes JM, Marchal-Crespo L. Control strategies used in lower limb exoskeletons for gait rehabilitation after brain injury: a systematic review and analysis of clinical effectiveness. J Neuroeng Rehabil 2023; 20:23. [PMID: 36805777 PMCID: PMC9938998 DOI: 10.1186/s12984-023-01144-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Accepted: 01/07/2023] [Indexed: 02/21/2023] Open
Abstract
BACKGROUND In the past decade, there has been substantial progress in the development of robotic controllers that specify how lower-limb exoskeletons should interact with brain-injured patients. However, it is still an open question which exoskeleton control strategies can more effectively stimulate motor function recovery. In this review, we aim to complement previous literature surveys on the topic of exoskeleton control for gait rehabilitation by: (1) providing an updated structured framework of current control strategies, (2) analyzing the methodology of clinical validations used in the robotic interventions, and (3) reporting the potential relation between control strategies and clinical outcomes. METHODS Four databases were searched using database-specific search terms from January 2000 to September 2020. We identified 1648 articles, of which 159 were included and evaluated in full-text. We included studies that clinically evaluated the effectiveness of the exoskeleton on impaired participants, and which clearly explained or referenced the implemented control strategy. RESULTS (1) We found that assistive control (100% of exoskeletons) that followed rule-based algorithms (72%) based on ground reaction force thresholds (63%) in conjunction with trajectory-tracking control (97%) were the most implemented control strategies. Only 14% of the exoskeletons implemented adaptive control strategies. (2) Regarding the clinical validations used in the robotic interventions, we found high variability on the experimental protocols and outcome metrics selected. (3) With high grade of evidence and a moderate number of participants (N = 19), assistive control strategies that implemented a combination of trajectory-tracking and compliant control showed the highest clinical effectiveness for acute stroke. However, they also required the longest training time. With high grade of evidence and low number of participants (N = 8), assistive control strategies that followed a threshold-based algorithm with EMG as gait detection metric and control signal provided the highest improvements with the lowest training intensities for subacute stroke. Finally, with high grade of evidence and a moderate number of participants (N = 19), assistive control strategies that implemented adaptive oscillator algorithms together with trajectory-tracking control resulted in the highest improvements with reduced training intensities for individuals with chronic stroke. CONCLUSIONS Despite the efforts to develop novel and more effective controllers for exoskeleton-based gait neurorehabilitation, the current level of evidence on the effectiveness of the different control strategies on clinical outcomes is still low. There is a clear lack of standardization in the experimental protocols leading to high levels of heterogeneity. Standardized comparisons among control strategies analyzing the relation between control parameters and biomechanical metrics will fill this gap to better guide future technical developments. It is still an open question whether controllers that provide an on-line adaptation of the control parameters based on key biomechanical descriptors associated to the patients' specific pathology outperform current control strategies.
Collapse
Affiliation(s)
- Jesús de Miguel-Fernández
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Centre for Biomedical Engineering, Universitat Politècnica de Catalunya, Diagonal 647, 08028 Barcelona, Spain
- Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, 08950 Esplugues de Llobregat, Spain
| | | | - Erik Prinsen
- Roessingh Research and Development, Roessinghsbleekweg 33b, 7522AH Enschede, Netherlands
| | - Josep M. Font-Llagunes
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Centre for Biomedical Engineering, Universitat Politècnica de Catalunya, Diagonal 647, 08028 Barcelona, Spain
- Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, 08950 Esplugues de Llobregat, Spain
| | - Laura Marchal-Crespo
- Cognitive Robotics Department, Delft University of Technology, Mekelweg 2, 2628 Delft, Netherlands
- Motor Learning and Neurorehabilitation Lab, ARTORG Center for Biomedical Engineering Research, University of Bern, Freiburgstrasse 3, 3010 Bern, Switzerland
- Department of Rehabilitation Medicine, Erasmus MC University Medical Center, Doctor Molewaterplein 40, 3015 GD Rotterdam, The Netherlands
| |
Collapse
|
7
|
Zhou Y. Recent advances in wearable actuated ankle-foot orthoses: Medical effects, design, and control. Proc Inst Mech Eng H 2023; 237:163-178. [PMID: 36515408 DOI: 10.1177/09544119221142335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
This paper presents a survey on recent advances of wearable actuated ankle-foot orthoses (AAFOs). First of all, their medical functions are investigated. From the short-term aspect, they lead to rectification of pathological gaits, reduction of metabolic cost, and improvement of gait performance. After AAFO-based walking training with sufficient time, free walking performance can be enhanced. Then, key design factors are studied. First, primary design parameters are investigated. Second, common actuators are analysed. Third, human-robot interaction (HRI), ergonomics, safety, and application places, are considered. In the following section, control technologies are reviewed from the aspects of rehabilitation stages, gait feature quantities, and controller characteristics. Finally, existing problems are discussed; development trends are prospected.
Collapse
Affiliation(s)
- Yuan Zhou
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| |
Collapse
|
8
|
Lutanto A, Ubaidillah U, Imaduddin F, Choi SB, Lenggana BW. Development of Tiny Vane-Type Magnetorheological Brake Considering Quality Function Deployment. MICROMACHINES 2022; 14:26. [PMID: 36677087 PMCID: PMC9866983 DOI: 10.3390/mi14010026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 12/16/2022] [Accepted: 12/19/2022] [Indexed: 06/17/2023]
Abstract
Many studies focus on the torque-to-dimension ratio when designing magnetorheological brakes (MRB), especially for ankle foot orthosis (AFO) devices. Vane MRB is one type of MRB with a limited angle of motion that is naturally suitable to be applied to AFO. However, very few implement quality function deployment (QFD) when making MRB, whereas QFD is an essential factor in making product designs. In this study, a tiny vane-type MR brake (TVMRB) was successfully made using the QFD method. Torque characteristics are determined by analysis of magnetic flux density, theoretically, by 3D simulation, and by using Ansys Maxwell experimentally. For consideration, the analysis was carried out with fluid gap variations (0.5 mm, 0.75 mm, and 1 mm) and current variations (0.5-2 A with 0.5 A increments). As a result, ignoring the leakage of MR fluid (MRF), at a constant rotation of 10 rpm, the smallest torque of 6.14 Nm was obtained at the fluid gap variation of 1 mm and input current of 0.5 A, whereas the largest torque was 46.71 Nm at the fluid gap variation of 0.5 mm and input current of 2 A. Apart from torque, this article will also discuss other brake performances in the form of operational range and power consumption. Finally, the structure of the TVMRB design is compared with other designs presented in the House of Quality (HOQ).
Collapse
Affiliation(s)
- Agus Lutanto
- Department of Mechanical Engineering, Faculty of Engineering, Universitas Sebelas Maret, Surakarta 57126, Indonesia
| | - U Ubaidillah
- Department of Mechanical Engineering, Faculty of Engineering, Universitas Sebelas Maret, Surakarta 57126, Indonesia
| | - Fitrian Imaduddin
- Department of Mechanical Engineering, Faculty of Engineering, Universitas Sebelas Maret, Surakarta 57126, Indonesia
- Department of Mechanical Engineering, Islamic University of Madinah, Medina 42351, Saudi Arabia
| | - Seung-Bok Choi
- Department of Mechanical Engineering, The State University of New York, Korea (SUNY Korea), Incheon 21985, Republic of Korea
- Department of Mechanical Engineering, Industrial University of Ho Minh City (IUH), Ho Chi Minh City 70000, Vietnam
| | - Bhre Wangsa Lenggana
- Department of Mechanical Engineering, Faculty of Engineering, Universitas Sebelas Maret, Surakarta 57126, Indonesia
| |
Collapse
|
9
|
Zhou C, Yang Z, Li K, Ye X. Research and Development of Ankle-Foot Orthoses: A Review. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22176596. [PMID: 36081055 PMCID: PMC9460335 DOI: 10.3390/s22176596] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 08/28/2022] [Accepted: 08/29/2022] [Indexed: 05/14/2023]
Abstract
The ankle joint is one of the important joints of the human body to maintain the ability to walk. Diseases such as stroke and ankle osteoarthritis could weaken the body's ability to control joints, causing people's gait to be out of balance. Ankle-foot orthoses can assist users with neuro/muscular or ankle injuries to restore their natural gait. Currently, passive ankle-foot orthoses are mostly designed to fix the ankle joint and provide support for walking. With the development of materials, sensing, and control science, semi-active orthoses that release mechanical energy to assist walking when needed and can store the energy generated by body movement in elastic units, as well as active ankle-foot orthoses that use external energy to transmit enhanced torque to the ankle, have received increasing attention. This article reviews the development process of ankle-foot orthoses and proposes that the integration of new ankle-foot orthoses with rehabilitation technologies such as monitoring or myoelectric stimulation will play an important role in reducing the walking energy consumption of patients in the study of human-in-the-loop models and promoting neuro/muscular rehabilitation.
Collapse
Affiliation(s)
- Congcong Zhou
- Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, 3 East Qingchun Road, Hangzhou 310016, China
- Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Zhao Yang
- Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Kaitai Li
- Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Xuesong Ye
- Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China
- Correspondence:
| |
Collapse
|
10
|
de Miguel-Fernandez J, Pescatore C, Mesa-Garrido A, Rikhof C, Prinsen E, Font-Llagunes JM, Lobo-Prat J. Immediate Biomechanical Effects of Providing Adaptive Assistance With an Ankle Exoskeleton in Individuals After Stroke. IEEE Robot Autom Lett 2022. [DOI: 10.1109/lra.2022.3183799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Jesus de Miguel-Fernandez
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Centre for Biomedical Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain
| | - Camille Pescatore
- ABLE Human Motion, Universitat Politècnica de Catalunya, Barcelona, Spain
| | - Alba Mesa-Garrido
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Centre for Biomedical Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain
| | - Cindy Rikhof
- Roessingh Research and Development, Enschede, AH, Netherlands
| | - Erik Prinsen
- Roessingh Research and Development, Enschede, AH, Netherlands
| | - Josep M. Font-Llagunes
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Centre for Biomedical Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain
| | - Joan Lobo-Prat
- ABLE Human Motion, Universitat Politècnica de Catalunya, Barcelona, Spain
| |
Collapse
|
11
|
Lora-Millan JS, Moreno JC, Rocon E. Coordination Between Partial Robotic Exoskeletons and Human Gait: A Comprehensive Review on Control Strategies. Front Bioeng Biotechnol 2022; 10:842294. [PMID: 35694226 PMCID: PMC9174608 DOI: 10.3389/fbioe.2022.842294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Accepted: 04/28/2022] [Indexed: 12/02/2022] Open
Abstract
Lower-limb robotic exoskeletons have become powerful tools to assist or rehabilitate the gait of subjects with impaired walking, even when they are designed to act only partially over the locomotor system, as in the case of unilateral or single-joint exoskeletons. These partial exoskeletons require a proper method to synchronize their assistive actions and ensure correct inter-joint coordination with the user’s gait. This review analyzes the state of the art of control strategies to coordinate the assistance provided by these partial devices with the actual gait of the wearers. We have analyzed and classified the different approaches independently of the hardware implementation, describing their basis and principles. We have also reviewed the experimental validations of these devices for impaired and unimpaired walking subjects to provide the reader with a clear view of their technology readiness level. Eventually, the current state of the art and necessary future steps in the field are summarized and discussed.
Collapse
Affiliation(s)
- Julio S. Lora-Millan
- Centre for Automation and Robotics, Consejo Superior de Investigaciones Científicas-Universidad Politécnica de Madrid, CSIC-UPM, Madrid, Spain
- Electronic Technology Department, Universidad Rey Juan Carlos, Madrid, Spain
| | - Juan C. Moreno
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Madrid, Spain
| | - E. Rocon
- Centre for Automation and Robotics, Consejo Superior de Investigaciones Científicas-Universidad Politécnica de Madrid, CSIC-UPM, Madrid, Spain
- *Correspondence: E. Rocon,
| |
Collapse
|
12
|
Hu X, Zeng X, Xu Y, Luo C, Jia L, Zhao Z, Sun Z, Qu X. A Soft Robotic Intervention for Gait Enhancement in Older Adults. IEEE Trans Neural Syst Rehabil Eng 2021; 29:1838-1847. [PMID: 34469304 DOI: 10.1109/tnsre.2021.3109729] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Falls continue to be a major safety and health concern for older adults. Researchers reported that increased gait variability was associated with increased fall risks. In the present study, we proposed a novel wearable soft robotic intervention and examined its effects on improving gait variability in older adults. The robotic system used customized pneumatic artificial muscles (PAMs) to provide assistive torque for ankle dorsiflexion during walking. Twelve older adults with low fall risks and twelve with medium-high fall risks participated in an experiment. The participants were asked to walk on a treadmill under no soft robotic intervention, inactive soft robotic intervention, and active soft robotic intervention, and their gait variability during treadmill walking was measured. The results showed that the proposed soft robotic intervention could reduce step length variability for elderly people with medium-high fall risks. These findings provide supporting evidence that the proposed soft robotic intervention could potentially serve as an effective solution to fall prevention for older adults.
Collapse
|
13
|
Kim W, Park H, Kim J. Compact Flat Fabric Pneumatic Artificial Muscle (ffPAM) for Soft Wearable Robotic Devices. IEEE Robot Autom Lett 2021. [DOI: 10.1109/lra.2021.3062012] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
14
|
Alnajjar F, Zaier R, Khalid S, Gochoo M. Trends and Technologies in Rehabilitation of Foot Drop: A Systematic Review. Expert Rev Med Devices 2021; 18:31-46. [PMID: 33249938 DOI: 10.1080/17434440.2021.1857729] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2020] [Accepted: 11/26/2020] [Indexed: 10/22/2022]
Abstract
INTRODUCTION Foot Drop (FD) is a condition, which is very commonly found in post-stoke patients; however it can also be seen in patients with multiple sclerosis, and cerebral palsy. It is a sign of neuromuscular damage caused by the weakness of the muscles. There are various approaches of FD's rehabilitation, such as physiotherapy, surgery, and the use of technological devices. Recently, researchers have worked on developing various technologies to enhance assisting and rehabilitation of FD. AREAS COVERED This review analyzes different types of technologies available for FD. This include devices that are available commercially or still under research. 101 studies published between 2015 and 2020 were identified for the review, many were excluded due to various reasons, e.g., were not robot-based devices, did not include FD as one of the targeted diseases, or was insufficient information. 24 studies that met our inclusion criteria were assessed. These studies were further classified into two different categories: robot-based ankle-foot orthosis (RAFO) and Functional Electrical Stimulation (FES) devices. EXPERT OPINION Studies included showed that both RAFO and FES showed considerable improvement in the gait cycle of the patients. Future trends are inclining towards integrating FES with other neuro-concepts such as muscle-synergies for further developments.
Collapse
Affiliation(s)
- Fady Alnajjar
- Department of Computer Science and Software Engineering, College of Information Technology, United Arab Emirates University, Al Ain, UAE
- Intelligent Behavior Control Unit, RIKEN, Centre for Brain Science, Wako, Japan
| | - Riadh Zaier
- Department of Mechanical and Industrial Engineering, College of Engineering, Sultan Qaboos University, Al Khoudh, Muscat, Oman
| | - Sumayya Khalid
- Department of Computer Science and Software Engineering, College of Information Technology, United Arab Emirates University, Al Ain, UAE
| | - Munkhjargal Gochoo
- Department of Computer Science and Software Engineering, College of Information Technology, United Arab Emirates University, Al Ain, UAE
- School of Information and Communication Technology, Ulaanbaatar, Mongolia
| |
Collapse
|