Sanaat A, Amini M, Arabi H, Zaidi H. The quest for multifunctional and dedicated PET instrumentation with irregular geometries. Ann Nucl Med 2024; 38:31-70. [PMID: 37952197 PMCID: PMC10766666 DOI: 10.1007/s12149-023-01881-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Accepted: 10/09/2023] [Indexed: 11/14/2023]
Abstract
We focus on reviewing state-of-the-art developments of dedicated PET scanners with irregular geometries and the potential of different aspects of multifunctional PET imaging. First, we discuss advances in non-conventional PET detector geometries. Then, we present innovative designs of organ-specific dedicated PET scanners for breast, brain, prostate, and cardiac imaging. We will also review challenges and possible artifacts by image reconstruction algorithms for PET scanners with irregular geometries, such as non-cylindrical and partial angular coverage geometries and how they can be addressed. Then, we attempt to address some open issues about cost/benefits analysis of dedicated PET scanners, how far are the theoretical conceptual designs from the market/clinic, and strategies to reduce fabrication cost without compromising performance.
Collapse
Affiliation(s)
- Amirhossein Sanaat
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211, Geneva, Switzerland
| | - Mehdi Amini
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211, Geneva, Switzerland
| | - Hossein Arabi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211, Geneva, Switzerland
| | - Habib Zaidi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211, Geneva, Switzerland.
- Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, 9700 RB, Groningen, The Netherlands.
- Department of Nuclear Medicine, University of Southern Denmark, 500, Odense, Denmark.
- University Research and Innovation Center, Óbuda University, Budapest, Hungary.
| |
Collapse
|
2
|
Teimoorisichani M, Goertzen AL. A Cube-based Dual-GPU List-mode Reconstruction Algorithm for PET Imaging. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2022. [DOI: 10.1109/trpms.2021.3077012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
3
|
Bouziri H, Pepin CM, Koua K, Benhouria M, Paulin C, Ouyang J, Normandin M, Pratte JF, El Fakhri G, Lecomte R, Fontaine R. Investigation of a Model-based Time-over-threshold Technique for Phoswich Crystal Discrimination. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2022; 6:393-403. [PMID: 35372739 PMCID: PMC8974315 DOI: 10.1109/trpms.2021.3077412] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The best crystal identification (CI) algorithms proposed so far for phoswich detectors are based on adaptive filtering and pulse shape discrimination (PSD). However, these techniques require free running analog to digital converters, which is no longer possible with the ever increasing pixelization of new detectors. We propose to explore the dual-threshold time-over-threshold (ToT) technique, used to measure events energy and time of occurence, as a more robust solution for crystal identification with broad energy windows in phoswich detectors. In this study, phoswich assemblies made of various combinations of LGSO and LYSO scintillators with decay times in the range 30 to 65 ns were investigated for the LabPET II detection front-end. The electronic readout is based on a 4 × 8 APD array where pixels are individually coupled to charge sensitive preamplifiers followed by first order CR-RC shapers with 75 ns peaking time. Crystal identification data were sorted out based on the measurements of likeliness between acquired signals and a time domain model of the analog front-end. Results demonstrate that crystal identification can be successfully performed using a dual-threshold ToT scheme with a discrimination accuracy of 99.1% for LGSO (30 ns)/LGSO (45 ns), 98.1% for LGSO (65 ns)/LYSO (40 ns) and 92.1% for LYSO (32 ns)/LYSO (47 ns), for an energy window of [350-650] keV. Moreover, the method shows a discrimination accuracy >97% for the two first pairs and ~90% for the last one when using a wide energy window of [250-650] keV.
Collapse
Affiliation(s)
- Haithem Bouziri
- Interdisciplinary Institute for Technological Innovation (3IT) and with the Department of Electrical and Computer Engineering, Université de Sherbrooke, Sherbrooke, QC, Canada J1K 0A5
| | - Catherine M Pepin
- Sherbrooke Molecular Imaging Center, Department of Nuclear Medicine and Radiobiology, Université de Sherbrooke, Sherbrooke, QC, Canada J1H 5N4
| | - Konin Koua
- Interdisciplinary Institute for Technological Innovation (3IT) and with the Department of Electrical and Computer Engineering, Université de Sherbrooke, Sherbrooke, QC, Canada J1K 0A5
| | - Maher Benhouria
- Interdisciplinary Institute for Technological Innovation (3IT) and with the Department of Electrical and Computer Engineering, Université de Sherbrooke, Sherbrooke, QC, Canada J1K 0A5
| | - Caroline Paulin
- Interdisciplinary Institute for Technological Innovation (3IT) and with the Department of Electrical and Computer Engineering, Université de Sherbrooke, Sherbrooke, QC, Canada J1K 0A5
| | - Jinsong Ouyang
- Gordon Center for Medical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114 USA
| | - Marc Normandin
- Gordon Center for Medical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114 USA
| | - Jean-François Pratte
- Interdisciplinary Institute for Technological Innovation (3IT) and with the Department of Electrical and Computer Engineering, Université de Sherbrooke, Sherbrooke, QC, Canada J1K 0A5
| | - Georges El Fakhri
- Gordon Center for Medical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114 USA
| | - Roger Lecomte
- Sherbrooke Molecular Imaging Center, Department of Nuclear Medicine and Radiobiology, Université de Sherbrooke, Sherbrooke, QC, Canada J1H 5N4
| | - Réjean Fontaine
- Interdisciplinary Institute for Technological Innovation (3IT) and with the Department of Electrical and Computer Engineering, Université de Sherbrooke, Sherbrooke, QC, Canada J1K 0A5
| |
Collapse
|
4
|
Kang HG, Nishikido F, Yamaya T. A staggered 3-layer DOI PET detector using BaSO4 reflector for enhanced crystal identification and inter-crystal scattering event discrimination capability. Biomed Phys Eng Express 2021; 7. [DOI: 10.1088/2057-1976/abf6a8] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Accepted: 04/09/2021] [Indexed: 01/22/2023]
|
5
|
Bläckberg L, Sajedi S, El Fakhri G, Sabet H. A layered single-side readout depth of interaction time-of-flight-PET detector. Phys Med Biol 2021; 66:045025. [PMID: 33570050 PMCID: PMC8130834 DOI: 10.1088/1361-6560/abd592] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
We are exploring a scintillator-based PET detector with potential of high sensitivity, depth of interaction (DOI) capability, and timing resolution, with single-side readout. Our design combines two previous concepts: (1) multiple scintillator arrays stacked with relative offset, yielding inherent DOI information, but good timing performance has not been demonstrated with conventional light sharing readout. (2) Single crystal array with one-to-one coupling to the photodetector, showing superior timing performance compared to its light sharing counterparts, but lacks DOI. The combination, where the first layer of a staggered design is coupled one-to-one to a photodetector array, may provide both DOI and timing resolution and this concept is here evaluated through light transport simulations. Results show that: (1) unpolished crystal pixels in the staggered configuration yield better performance across all metrics compared to polished pixels, regardless of readout scheme. (2) One-to-one readout of the first layer allows for accurate DOI extraction using a single threshold. The number of multi pixel photon counter (MPPC) pixels with signal amplitudes exceeding the threshold corresponds to the interaction layer. This approach was not possible with conventional light sharing readout. (3) With a threshold of 2 optical photons, the layered approach with one-to-one coupled first layer improves timing close to the MPPC compared to the conventional one-to-one coupling non-DOI detector, due to effectively reduced crystal thickness. Single detector timing resolution values of 91, 127, 151 and 164 ps were observed per layer in the 4-layer design, to be compared to 148 ps for the single array with one-to-one coupling. (4) For the layered design with light sharing readout, timing improves with increased MPPC pixel size due to higher signal per channel. In conclusion, the combination of straightforward DOI determination, good timing performance, and relatively simple design makes the proposed concept promising for DOI-Time-of-Flight PET detectors.
Collapse
Affiliation(s)
- L Bläckberg
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital & Harvard Medical School, Boston, MA, United States of America
| | - S Sajedi
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital & Harvard Medical School, Boston, MA, United States of America
| | - G El Fakhri
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital & Harvard Medical School, Boston, MA, United States of America
| | - H Sabet
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital & Harvard Medical School, Boston, MA, United States of America
| |
Collapse
|
6
|
Gravel P, Surti S, Krishnamoorthy S, Karp JS, Matej S. Spatially-variant image-based modeling of PSF deformations with application to a limited angle geometry from a dual-panel breast-PET imager. Phys Med Biol 2019; 64:225015. [PMID: 31569078 DOI: 10.1088/1361-6560/ab4914] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Dual-panel PET system configuration can lead to spatially variable point-spread functions (PSF) of considerable deformations due to depth-of-interaction effects and limited angular coverage. If not modelled properly, these effects result in decreased and inconsistent recovery of lesion activity across the field-of-view (FOV), as well as mispositioning of lesions in the reconstructed image caused by strong PSF asymmetries. We implemented and evaluated models of such PSF deformations with spatially-variant image-based resolution modeling (IRM) within reconstruction (varRM) using the Direct Image REConstruction for Time-of-flight (DIRECT) method and within post-reconstruction deconvolution methods. In addition, DIRECT reconstruction was performed with a spatially-invariant IRM (invRM) and without resolution modeling (noRM) for comparison. The methods were evaluated using simulated data for a realistic breast model with a set of 5 mm lesions located throughout the FOV of a dual-panel Breast-PET scanner. We simulated high-count data to focus on the ability of each method to correctly recover the PSF deformations, and a clinically realistic count level to assess the impact of low count data on the quantitative performance of the evaluated techniques. Performance of the methods evaluated herein was assessed by comparing lesion activity recovery (%BIAS), consistency (%SD) across the FOV, overall error (%RMSE), and recovery of each lesion location. As expected, all techniques using IRM provide considerable improvement over the noRM reconstruction. For the high-count cases, the overall quantitative performance of all IRM techniques, whether within reconstruction or within post-reconstruction, is similar if the lesion location misplacements are ignored. However, invRM provides less consistent performance on activity across lesions and is not able to recover accurate lesion locations. For a clinically realistic count level, varRM reconstruction consistently outperforms all compared approaches, while the post-reconstruction IRM approaches exhibit higher %SD and %RMSE values due to being more affected by the data noise than the within-reconstruction IRM approaches.
Collapse
Affiliation(s)
- Paul Gravel
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America
| | | | | | | | | |
Collapse
|
7
|
Teimoorisichani M, Goertzen AL. Count rate performance of brain-dedicated PET scanners: a Monte Carlo simulation study. Phys Med Biol 2019; 64:215013. [PMID: 31530762 DOI: 10.1088/1361-6560/ab452f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In recent years, there has been a renewed interest in brain-dedicated PET imaging systems, particularly in the context of combined PET/MR imaging. We are currently designing a brain-dedicated PET insert suitable for an ultra-high field brain-dedicated MR scanner, the Siemens Magnetom 7T MR scanner. In this paper, an investigation on the count rate performance of several possible detectors through a series of Monte Carlo simulations is reported. Brain-dedicated PET scanners with a lutetium oxyorthosilicate scintillator and a detector area of 0.04 (1 crystal per detector) to 101.37 (2500 crystals per detector) cm2, detector thickness of 10 to 20 mm and a fixed crystal pitch of ~2 mm were simulated. The count rate performance of each scanner was evaluated as a function of detector deadtime type and constant, coincidence timing window and lower level discriminator. Also, the effects of activity outside the field-of-view (FOV) on the count rate performance of each scanner were studied. For each detector geometry and performance metric, the scanner singles rate, scanner sensitivity and noise equivalent count rate as a function of activity in the FOV were measured. It was seen that scanners with detectors comprised a few crystal elements showed reduced scanner sensitivity due to a high number of inter-detector scattering. The count rate performance of scanners with large detectors, on the other hand, was mainly determined by the deadtime properties of the detectors. A model for the count rate performance of the scanner with each studied detector is presented in this work.
Collapse
Affiliation(s)
- Mohammadreza Teimoorisichani
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB R3T 2N2, Canada. Author to whom any correspondence should be addressed
| | | |
Collapse
|
8
|
Teimoorisichani M, Goertzen AL. A study of inter-crystal scatter in dual-layer offset scintillator arrays for brain-dedicated PET scanners. Phys Med Biol 2019; 64:115007. [PMID: 30933936 DOI: 10.1088/1361-6560/ab1503] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A dual-layer offset (DLO) detector enables depth-of-interaction (DOI) through light sharing between two layers of scintillation arrays with a single-ended readout (SER) scheme. However, the SER scheme in DLO detectors may lead to a layer misassignment when inter-crystal scattering occurs. The aim of this work is to study inter-crystal scattering and evaluate the effects of layer misidentifications in DLO detectors on the performance of scanners suitable for a brain-dedicated PET insert. The influence of layer misidentification on the coincidence response functions (CRFs) of 3 different DLO detectors with total/front/back layer thicknesses of 15/6/9 mm, 20/8/12 mm, and 25/7.5/17.5 mm and a crystal width of about 3 mm was studied through Monte Carlo simulations. To overcome layer misidentification, we studied a practical DLO detector design in which each layer can be read out independently through a discrete-layer readout (DLR) scheme where light sharing between the layers is avoided. The CRFs of the mentioned DLO detectors assuming SER and DLR were analyzed. To evaluate the effects of layer misidentification on image quality, images of a Derenzo-like phantom were also reconstructed for all DLO and their equivalent single layer PET scanners. Our analysis showed that layer misassignments due to inter-crystal scatter in DLO detectors mainly has effect on the full-width at tenth maximum of the CRFs. According to the reconstructed images of the phantom, no significant improvements in the quality of the images were seen when SER was replaced with DLR. The results suggest that layer misidentification in DLO detectors does not play an important role in the quality of the PET images.
Collapse
Affiliation(s)
- Mohammadreza Teimoorisichani
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, R3T 2N2, Canada. Author to whom any correspondence should be addressed
| | | |