Jiang Z, Polf JC, Barajas CA, Gobbert MK, Ren L. A feasibility study of enhanced prompt gamma imaging for range verification in proton therapy using deep learning. Phys Med Biol 2023; 68:10.1088/1361-6560/acbf9a. [PMID: 36848674 PMCID: PMC10173868 DOI: 10.1088/1361-6560/acbf9a] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Accepted: 02/27/2023] [Indexed: 03/01/2023]
Abstract
Background and objective. Range uncertainty is a major concern affecting the delivery precision in proton therapy. The Compton camera (CC)-based prompt-gamma (PG) imaging is a promising technique to provide 3Din vivorange verification. However, the conventional back-projected PG images suffer from severe distortions due to the limited view of the CC, significantly limiting its clinical utility. Deep learning has demonstrated effectiveness in enhancing medical images from limited-view measurements. But different from other medical images with abundant anatomical structures, the PGs emitted along the path of a proton pencil beam take up an extremely low portion of the 3D image space, presenting both the attention and the imbalance challenge for deep learning. To solve these issues, we proposed a two-tier deep learning-based method with a novel weighted axis-projection loss to generate precise 3D PG images to achieve accurate proton range verification.Materials and methods: the proposed method consists of two models: first, a localization model is trained to define a region-of-interest (ROI) in the distorted back-projected PG image that contains the proton pencil beam; second, an enhancement model is trained to restore the true PG emissions with additional attention on the ROI. In this study, we simulated 54 proton pencil beams (energy range: 75-125 MeV, dose level: 1 × 109protons/beam and 3 × 108protons/beam) delivered at clinical dose rates (20 kMU min-1and 180 kMU min-1) in a tissue-equivalent phantom using Monte-Carlo (MC). PG detection with a CC was simulated using the MC-Plus-Detector-Effects model. Images were reconstructed using the kernel-weighted-back-projection algorithm, and were then enhanced by the proposed method.Results. The method effectively restored the 3D shape of the PG images with the proton pencil beam range clearly visible in all testing cases. Range errors were within 2 pixels (4 mm) in all directions in most cases at a higher dose level. The proposed method is fully automatic, and the enhancement takes only ∼0.26 s.Significance. Overall, this preliminary study demonstrated the feasibility of the proposed method to generate accurate 3D PG images using a deep learning framework, providing a powerful tool for high-precisionin vivorange verification of proton therapy.
Collapse
Affiliation(s)
- Zhuoran Jiang
- Medical Physics Graduate Program, Duke University, Durham, NC, 27705, USA
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, 27710, USA
| | - Jerimy C. Polf
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, 21201, USA
| | - Carlos A. Barajas
- Department of Mathematics and Statistics, University of Maryland, Baltimore County, Baltimore, MD, 21250, USA
| | - Matthias K. Gobbert
- Department of Mathematics and Statistics, University of Maryland, Baltimore County, Baltimore, MD, 21250, USA
| | - Lei Ren
- Medical Physics Graduate Program, Duke University, Durham, NC, 27705, USA
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, 27710, USA
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, 21201, USA
| |
Collapse
|
2
|
Viegas R, Roser J, Barrientos L, Borja-Lloret M, Casaña J, López JG, Jiménez-Ramos M, Hueso-González F, Ros A, Llosá G. Characterization of a Compton camera based on the TOFPET2 ASIC. Radiat Phys Chem Oxf Engl 1993 2023. [DOI: 10.1016/j.radphyschem.2022.110507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
3
|
Roser J, Barrientos L, Bernabéu J, Borja-Lloret M, Muñoz E, Ros A, Viegas R, Llosá G. Joint image reconstruction algorithm in Compton cameras. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac7b08] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Accepted: 06/21/2022] [Indexed: 11/11/2022]
Abstract
Abstract
Objective. To demonstrate the benefits of using an joint image reconstruction algorithm based on the List Mode Maximum Likelihood Expectation Maximization that combines events measured in different channels of information of a Compton camera. Approach. Both simulations and experimental data are employed to show the algorithm performance. Main results. The obtained joint images present improved image quality and yield better estimates of displacements of high-energy gamma-ray emitting sources. The algorithm also provides images that are more stable than any individual channel against the noisy convergence that characterizes Maximum Likelihood based algorithms. Significance. The joint reconstruction algorithm can improve the quality and robustness of Compton camera images. It also has high versatility, as it can be easily adapted to any Compton camera geometry. It is thus expected to represent an important step in the optimization of Compton camera imaging.
Collapse
|
4
|
Polf JC, Barajas CA, Peterson SW, Mackin DS, Beddar S, Ren L, Gobbert MK. Applications of Machine Learning to Improve the Clinical Viability of Compton Camera Based in vivo Range Verification in Proton Radiotherapy. FRONTIERS IN PHYSICS 2022; 10:838273. [PMID: 36119562 PMCID: PMC9481064 DOI: 10.3389/fphy.2022.838273] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
We studied the application of a deep, fully connected Neural Network (NN) to process prompt gamma (PG) data measured by a Compton camera (CC) during the delivery of clinical proton radiotherapy beams. The network identifies 1) recorded "bad" PG events arising from background noise during the measurement, and 2) the correct ordering of PG interactions in the CC to help improve the fidelity of "good" data used for image reconstruction. PG emission from a tissue-equivalent target during irradiation with a 150 MeV proton beam delivered at clinical dose rates was measured with a prototype CC. Images were reconstructed from both the raw measured data and the measured data that was further processed with a neural network (NN) trained to identify "good" and "bad" PG events and predict the ordering of individual interactions within the good PG events. We determine if NN processing of the CC data could improve the reconstructed PG images to a level in which they could provide clinically useful information about the in vivo range and range shifts of the proton beams delivered at full clinical dose rates. Results showed that a deep, fully connected NN improved the achievable contrast to noise ratio (CNR) in our images by more than a factor of 8x. This allowed the path, range, and lateral width of the clinical proton beam within a tissue equivalent target to easily be identified from the PG images, even at the highest dose rates of a 150 MeV proton beam used for clinical treatments. On average, shifts in the beam range as small as 3 mm could be identified. However, when limited by the amount of PG data measured with our prototype CC during the delivery of a single proton pencil beam (~1 × 109 protons), the uncertainty in the reconstructed PG images limited the identification of range shift to ~5 mm. Substantial improvements in CC images were obtained during clinical beam delivery through NN pre-processing of the measured PG data. We believe this shows the potential of NNs to help improve and push CC-based PG imaging toward eventual clinical application for proton RT treatment delivery verification.
Collapse
Affiliation(s)
- Jerimy C. Polf
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, United States
| | - Carlos A. Barajas
- Department of Mathematics and Statistics, University of Maryland Baltimore County, Baltimore, MD, United States
| | | | - Dennis S. Mackin
- Department of Medical Physics, University of Texas M.D. Anderson Cancer Center, Houston, TX, United States
| | - Sam Beddar
- Department of Medical Physics, University of Texas M.D. Anderson Cancer Center, Houston, TX, United States
| | - Lei Ren
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, United States
| | - Matthias K. Gobbert
- Department of Mathematics and Statistics, University of Maryland Baltimore County, Baltimore, MD, United States
| |
Collapse
|