1
|
Ilkhechi AK, Ceroici C, Li Z, Zemp R. Transparent capacitive micromachined ultrasonic transducer (CMUT) arrays for real-time photoacoustic applications. OPTICS EXPRESS 2020; 28:13750-13760. [PMID: 32403843 DOI: 10.1364/oe.390612] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Accepted: 03/30/2020] [Indexed: 05/26/2023]
Abstract
Photoacoustic imaging has shown great potential for non-invasive high-resolution deep-tissue imaging. Minimizing the optical and acoustic paths for excitation and detection could significantly increase the signal-to-noise ratio. This could be accomplished by transparent transducers permitting through-transducer illumination. However, most ultrasound transducers are not optically transparent. Capacitive micromachined ultrasound transducer (CMUT) technology has compelling properties compared to piezoelectric transducers such as wide bandwidth and high receive sensitivity. Here, we introduce transparent CMUT linear arrays with high transparency in the visible and near-infrared range. To fabricate the devices, we used an adhesive wafer bonding technique using photosensitive benzocyclobutene (BCB) as both a structural and adhesive layer with a glass-indium-tin-oxide (ITO) substrate. Silicon nitride is used as the membrane material ensuring hermiticity and optical transparency. Our fabricated transducer arrays consist of 64 and 128 elements with immersion operation frequency of 8 MHz, enabling high-resolution imaging. ITO, along with thin metal strips, are used as a conductive layer for the top electrodes with minimal impact on device transparency. Fabricated devices have shown average transparency of 70% in the visible wavelength range that goes up to 90% in the near-infrared range. Arrays are wire-bonded to interfacing electronics and connected to a research ultrasound platform for phantom imaging. Arrays exhibited signal-to-noise (SNR) of 40 dB with 30V bias voltage and laser fluence of 13.5 mJ/cm2. Arrays with 128 channels provided lateral and axial resolutions of 234 µm and 220 µm, respectively.
Collapse
|
2
|
Wong CM, Chen Y, Luo H, Dai J, Lam KH, Chan HLW. Development of a 20-MHz wide-bandwidth PMN-PT single crystal phased-array ultrasound transducer. ULTRASONICS 2017; 73:181-186. [PMID: 27664869 DOI: 10.1016/j.ultras.2016.09.012] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2016] [Revised: 09/01/2016] [Accepted: 09/11/2016] [Indexed: 06/06/2023]
Abstract
In this study, a 20-MHz 64-element phased-array ultrasound transducer with a one-wavelength pitch is developed using a PMN-30%PT single crystal and double-matching layer scheme. High piezoelectric (d33>1000pC/N) and electromechanical coupling (k33>0.8) properties of the single crystal with an optimized fabrication process involving the photolithography technique have been demonstrated to be suitable for wide-bandwidth (⩾70%) and high-sensitivity (insertion loss ⩽30dB) phased-array transducer application. A -6dBbandwidth of 91% and an insertion loss of 29dBfor the 20-MHz 64-element phased-array transducer were achieved. This result shows that the bandwidth is improved comparing with the investigated high-frequency (⩾20MHz) ultrasound transducers using piezoelectric ceramic and single crystal materials. It shows that this phased-array transducer has potential to improve the resolution of biomedical imaging, theoretically. Based on the hypothesis of resolution improvement, this phased-array transducer is capable for small animal (i.e. mouse and zebrafish) studies.
Collapse
Affiliation(s)
- Chi-Man Wong
- Department of Electrical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
| | - Yan Chen
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
| | - Haosu Luo
- Information Materials and Devices Research Center, Shanghai Institute of Ceramics, Chinese Academy of Science, Shanghai, China
| | - Jiyan Dai
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong.
| | - Kwok-Ho Lam
- Department of Electrical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong.
| | - Helen Lai-Wa Chan
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
| |
Collapse
|
3
|
Nakazawa M, Aoyagi T, Tabaru M, Nakamura K, Ueha S. Experimental study of underwater transmission characteristics of high-frequency 30 MHz polyurea ultrasonic transducer. ULTRASONICS 2014; 54:526-536. [PMID: 24035608 DOI: 10.1016/j.ultras.2013.08.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2013] [Revised: 07/28/2013] [Accepted: 08/06/2013] [Indexed: 06/02/2023]
Abstract
In this paper, we present the transmission characteristics of a polyurea ultrasonic transducer operating in water. In this study, we used a polyurea transducer with fundamental resonance at approximately 30 MHz. Firstly, acoustic pressure radiated from the transducer was measured using a hydrophone, which has a diameter of 0.2 mm. The transmission characteristics such as relative bandwidth, pulse width, and acoustic sensitivity were calculated from the experimental results. The results of the experiment showed a relative bandwidth of 50% and a pulse width of 0.061 μs. The acoustic sensitivity was 0.60 kPa/V with good linearity, where the correlation coefficient R in the fitting calculation was 0.996. A maximum pressure of 13.1 kPa was observed when the transducer was excited at a zero-to-peak voltage of 21 V. Moreover, we experimentally verified the results. The results of the pulse/echo experiment showed that the estimated diameters of the copper wires were 458 and 726 μm, where the differences between the actual and measured values were 15% and 4%, respectively. Acoustic streaming was also observed so that a particle velocity map was estimated by particle image velocimetry (PIV). The sound pressure calculated from the particle velocity obtained by PIV showed good agreement with the acoustic pressure measured using the hydrophone, where the differences between the calculated and measured values were 12-19%.
Collapse
Affiliation(s)
- Marie Nakazawa
- Precision and Intelligence Laboratory, Tokyo Institute of Technology, Nagatsuta-cho 4259, Midori-ku, Yokohama, Kanagawa 226-8503, Japan.
| | | | | | | | | |
Collapse
|
4
|
Bezanson A, Adamson R, Brown J. Fabrication and performance of a miniaturized 64-element high-frequency endoscopic phased array. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2014; 61:33-43. [PMID: 24402894 DOI: 10.1109/tuffc.2014.6689774] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
We have developed a 40-MHz, 64-element phased-array transducer packaged in a 2.5 x 3.1 mm endoscopic form factor. The array is a forward-looking semi-kerfed design based on a 0.68Pb(Mg(1/3)Nb(2/3))O(3) - 0.32PbTiO3 (PMN-32%PT) single-crystal wafer with an element-to-element pitch of 38 µm. To achieve a miniaturized form factor, a novel technique of wire bonding the array elements to a polyimide flexible circuit board oriented parallel to the forward looking ultrasound beam and perpendicular to the array was developed. A technique of partially dicing into the back of the array was also implemented to improve the directivity of the array elements. The array was fabricated with a single-layer P(VDF-TrFE)-copolymer matching layer and a polymethylpentene (TPX) lens for passive elevation focusing to a depth of 7 mm. The two-way -6-dB pulse bandwidth was measured to be 55% and the average electromechanical coupling (k(eff)) for the individual elements was measured to be 0.62. The one-way -6-dB directivities from several array elements were measured to be ±20°, which was shown to be an improvement over an identical kerfless array. The -3-dB elevation focus resulting from the TPX lens was measured to be 152 µm at the focal depth, and the focused lateral resolution was measured to be 80 µm at a steering angle of 0°. To generate beam profiles and images, the probe was connected to a commercial ultrasound imaging platform which was reprogrammed to allow for phased array transmit beamforming and receive data collection. The collected RF data were then processed offline using a numerical computing script to generate sector images. The radiation pattern for the beamformed transmit pulse was collected along with images of wire phantoms in water and tissue-equivalent medium with a dynamic range of 60 dB. Finally, ex vivo tissue images were generated of porcine brain tissue.
Collapse
|
5
|
Nakazawa M, Tabaru M, Aoyagi T, Nakamura K, Ueha S. Thickness design, fabrication, and evaluation of 100-MHz polyurea ultrasonic transducer. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2013; 60:2175-2188. [PMID: 24081266 DOI: 10.1109/tuffc.2013.2808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
In this paper, we present a polyurea transducer that works at 100 MHz under water. The transducer was designed using an equivalent circuit model so that an aluminum (top)-polyurea-aluminum (bottom)-polyimide layer had a resonant frequency of 100 MHz and output sound pressure became maximum at that frequency. The thicknesses of the top aluminum electrode, polyurea, and bottom aluminum electrode were determined to be 3.3, 3.5, and 1.7 μm, respectively. A 100-MHz polyurea transducer with the designed thickness was fabricated using deposition equipment. To evaluate the performance of the designed and fabricated polyurea transducer, transmission-reception experiments with pulsed and burst waves were carried out. The results show that transmitting and receiving ultrasounds at a frequency of 100 MHz are possible as expected with the thickness design. To evaluate actual use, B-mode imaging of an onion was also performed using the transducer, which was formed into a line-focused shape. The result shows that the outer layer of the onion, of 0.1 to 0.2 mm thickness, was successfully imaged.
Collapse
|
6
|
Jeong JS, Shung KK. Improved fabrication of focused single element P(VDF-TrFE) transducer for high frequency ultrasound applications. ULTRASONICS 2013; 53:455-458. [PMID: 23021238 PMCID: PMC3774315 DOI: 10.1016/j.ultras.2012.08.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2011] [Revised: 08/13/2012] [Accepted: 08/23/2012] [Indexed: 06/01/2023]
Abstract
We present an improved fabrication technique for the focused single element poly (vinylidene fluoride-trifluoroethylene) P(VDF-TrFE) transducer. In this work, a conductive epoxy for a backing layer was directly bonded to the 25μm thick P(VDF-TrFE) film and thus made it easy to conform the aperture of the P(VDF-TrFE) transducer. Two prototype focused P(VDF-TrFE) transducers with disk- and ring-type aperture were fabricated and their performance was evaluated using the UBM (Ultrasound Biomicroscopy) system with a wire phantom. All transducers had a spherically focused aperture with a low f-number (focal depth/aperture size=1). The center frequency of the disk-type P(VDF-TrFE) transducer was 23MHz and-6dB bandwidth was 102%. The ring-type P(VDF-TrFE) transducer had 20MHz center frequency and-6dB bandwidth of 103%. The measured pulse echo signal had reduced reverberation due to no additional adhesive layer between the P(VDF-TrFE) film and the backing layer. Hence, the proposed method is promising to fabricate a single element transducer using P(VDF-TrFE) film for high frequency applications.
Collapse
Affiliation(s)
- Jong Seob Jeong
- Department of Medical Biotechnology, Dongguk University-Seoul, Seoul 100-715, Republic of Korea.
| | | |
Collapse
|
7
|
Athanasopoulos GI, Carey SJ, Hatfield JV. Circuit design and simulation of a transmit beamforming ASIC for high-frequency ultrasonic imaging systems. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2011; 58:1320-1331. [PMID: 21768017 DOI: 10.1109/tuffc.2011.1952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
This paper describes the design of a programmable transmit beamformer application-specific integrated circuit (ASIC) with 8 channels for ultrasound imaging systems. The system uses a 20-MHz reference clock. A digital delay-locked loop (DLL) was designed with 50 variable delay elements, each of which provides a clock with different phase from a single reference. Two phase detectors compare the phase difference of the reference clock with the feedback clock, adjusting the delay of the delay elements to bring the feedback clock signal in phase with the reference clock signal. Two independent control voltages for the delay elements ensure that the mark space ratio of the pulses remain at 50%. By combining a 10- bit asynchronous counter with the delays from the DLL, each channel can be programmed to give a maximum time delay of 51 μs with 1 ns resolution. It can also give bursts of up to 64 pulses. Finally, for a single pulse, it can adjust the pulse width between 9 ns and 100 ns by controlling the current flowing through a capacitor in a one-shot circuit, for use with 40-MHz and 5-MHz transducers, respectively.
Collapse
|
8
|
Wang X, Fowlkes JB, Cannata JM, Hu C, Carson PL. Photoacoustic imaging with a commercial ultrasound system and a custom probe. ULTRASOUND IN MEDICINE & BIOLOGY 2011; 37:484-92. [PMID: 21276653 PMCID: PMC3040410 DOI: 10.1016/j.ultrasmedbio.2010.12.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2010] [Revised: 12/01/2010] [Accepted: 12/03/2010] [Indexed: 05/02/2023]
Abstract
Building photoacoustic imaging (PAI) systems by using stand-alone ultrasound (US) units makes it convenient to take advantage of the state-of-the-art ultrasonic technologies. However, the sometimes limited receiving sensitivity and the comparatively narrow bandwidth of commercial US probes may not be sufficient to acquire high quality photoacoustic images. In this work, a high-speed PAI system has been developed using a commercial US unit and a custom built 128-element piezoelectric-polymer array (PPA) probe using a P(VDF-TrFE) film and flexible circuit to define the elements. Since the US unit supports simultaneous signal acquisition from 64 parallel receive channels, PAI data for synthetic image formation from a 64- or 128-element array aperture can be acquired after a single or dual laser firing, respectively. Therefore, two-dimensional (2-D) B-scan imaging can be achieved with a maximum frame rate up to 10 Hz, limited only by the laser repetition rate. The uniquely properties of P(VDF-TrFE) facilitated a wide -6 dB receiving bandwidth of over 120% for the array. A specially designed 128-channel preamplifier board made the connection between the array and the system cable, which not only enabled element electrical impedance matching but also further elevated the signal-to-noise ratio (SNR) to further enhance the detection of weak photoacoustic signals. Through the experiments on phantoms and rabbit ears, the good performance of this PAI system was demonstrated.
Collapse
Affiliation(s)
- Xueding Wang
- Department of Radiology, University of Michigan, Ann Arbor, MI 48105, USA.
| | | | | | | | | |
Collapse
|