Argueta-Lozano AK, Castañeda-Martinez L, Bass V, Mateos MJ, Castillo-López JP, Perez-Badillo MP, Aguilar-Cortazar LO, Porras-Reyes F, Sollozo-Dupont MI, Torres-Robles F, Márquez-Flores J, Villaseñor-Navarro Y, Esquivel-Sirvent R, Rosado-Mendez IM. Inter- and Intra-Operator Variability of Regularized Backscatter Quantitative Ultrasound for the Characterization of Breast Masses. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2023; 42:2567-2582. [PMID: 37490582 DOI: 10.1002/jum.16292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Accepted: 05/27/2023] [Indexed: 07/27/2023]
Abstract
OBJECTIVES Here we report on the intra- and inter-operator variability of the backscatter coefficient (BSC) estimated with a new low-variance quantitative ultrasound (QUS) approach applied to breast lesions in vivo. METHODS Radiofrequency (RF) echo signals were acquired from 29 BIRADS 4 and 5 breast lesions in 2 sequential cohorts following 2 imaging protocols: cohort 1) radial and antiradial views, and cohort 2) short- and long-axis views. Protocol 2 was implemented after retraining and discussion on how to improve reproducibility. Each patient was scanned by at least 2 of 3 radiologists; each performed 3 acquisitions with transducer and patient repositioning in between acquisitions. BSC was estimated using a low-variance QUS approach based on regularization. Intra- and inter-operator variability of the intra-lesion median BSC was evaluated with a multifactorial ANOVA test (P-values) and the intraclass correlation coefficient (ICC). RESULTS Inter-operator variability was only significant in the first protocol (P < .007); ICCinter = .77 (95% CI .71-.82), indicating good inter-operator agreement. In the second protocol, the inter-operator variability was not significant (P > .05) and agreement was excellent (ICCinter = .92 [.89-.94]). In both protocols, the intra-operator variability was not significant. CONCLUSIONS Our findings demonstrate the need for standardizing image acquisition protocols for backscatter-based QUS to reduce inter-operator variability and ensure its successful translation to the characterization of suspicious breast masses.
Collapse
Affiliation(s)
- Ana K Argueta-Lozano
- Instituto de Física, Universidad Nacional Autónoma de México, Circuito de la Investigación Científica s/n, Ciudad Universitaria, Mexico City, Mexico
| | | | - Vivian Bass
- Instituto de Ciencias Aplicadas y Tecnología, Universidad Nacional Autónoma de México, Circuito Exterior S/N, Ciudad Universitaria, Mexico City, Mexico
| | - Maria-Julieta Mateos
- Graduate Program in Computer Science and Engineering, Universidad Nacional Autónoma de México, Ciudad Universitaria, Mexico City, Mexico
| | | | | | | | | | | | - Fabian Torres-Robles
- Instituto de Física, Universidad Nacional Autónoma de México, Circuito de la Investigación Científica s/n, Ciudad Universitaria, Mexico City, Mexico
| | - Jorge Márquez-Flores
- Instituto de Ciencias Aplicadas y Tecnología, Universidad Nacional Autónoma de México, Circuito Exterior S/N, Ciudad Universitaria, Mexico City, Mexico
| | | | - Raul Esquivel-Sirvent
- Instituto de Física, Universidad Nacional Autónoma de México, Circuito de la Investigación Científica s/n, Ciudad Universitaria, Mexico City, Mexico
| | - Ivan M Rosado-Mendez
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA
- Department of Radiology, University of Wisconsin-Madison, Madison, WI, USA
| |
Collapse
|
2
|
Rosado-Mendez IM. Recent Advances in Attenuation Estimation. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2023; 1403:85-104. [PMID: 37495916 DOI: 10.1007/978-3-031-21987-0_6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/28/2023]
Abstract
This chapter reviews some of the recent advances in the estimation of the local and the total attenuation, with an emphasis on reducing the bias and variance of the estimates. A special focus is put on describing the effect of power spectrum estimation on bias and variance, the introduction of regularization strategies, as well as on eliminating the need to use reference phantoms for compensating for system dependent effects.
Collapse
|
3
|
Rafati I, Destrempes F, Yazdani L, Gesnik M, Tang A, Cloutier G. Regularized Ultrasound Phantom-Free Local Attenuation Coefficient Slope (ACS) Imaging in Homogeneous and Heterogeneous Tissues. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:3338-3352. [PMID: 36318570 DOI: 10.1109/tuffc.2022.3218920] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Attenuation maps or measurements based on the local attenuation coefficient slope (ACS) in quantitative ultrasound (QUS) have shown potential for the diagnosis of liver steatosis. In liver cancers, tissue abnormalities and tumors detected using ACS are also of interest to provide new image contrast to clinicians. Current phantom-based approaches have the limitation of assuming a comparable speed of sound between the reference phantom and insonified tissues. Moreover, these methods present the inconvenience for operators to acquire data on phantoms and patients. The main goal was to alleviate these drawbacks by proposing a methodology for constructing phantom-free regularized (PF-R) local ACS maps and investigate the performance in both homogeneous and heterogeneous media. The proposed method was tested on two tissue-mimicking media with different ACS constructed as homogeneous phantoms, side-by-side and top-to-bottom phantoms, and inclusion phantoms with different attenuations. Moreover, an in vivo proof-of-concept was performed on healthy, steatotic, and cancerous human liver datasets. Modifications brought to previous works include: 1) a linear interpolation of the power spectrum in the log scale; 2) the relaxation of the underlying hypothesis on the diffraction factor; 3) a generalization to nonhomogeneous local ACS; and 4) an adaptive restriction of frequencies to a more reliable range than the usable frequency range. Regularization was formulated as a generalized least absolute shrinkage and selection operator (LASSO), and a variant of the Bayesian information criterion (BIC) was applied to estimate the Lagrangian multiplier on the LASSO constraint. In addition, we evaluated the proposed algorithm when applying median filtering before and after regularization. Tests conducted showed that the PF-R yielded robust results in all tested conditions, suggesting potential for additional validation as a diagnosis method.
Collapse
|
4
|
Lok UW, Gong P, Huang C, Tang S, Zhou C, Yang L, Watt KD, Callstrom M, Trzasko JD, Chen S. Reverberation clutter signal suppression in ultrasound attenuation estimation using wavelet-based robust principal component analysis. Phys Med Biol 2022; 67. [PMID: 35358950 PMCID: PMC9297384 DOI: 10.1088/1361-6560/ac62fd] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Accepted: 03/31/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Objective. Ultrasound attenuation coefficient estimation (ACE) has diagnostic potential for clinical applications such as quantifying fat content in the liver. Previously, we have proposed a system-independent ACE technique based on spectral normalization of different frequencies, called the reference frequency method (RFM). This technique does not require a well-calibrated reference phantom for normalization. However, this method may be vulnerable to severe reverberation clutter introduced by the body wall. The clutter superimposed on liver echoes may bias the estimation. Approach. We proposed to use robust principal component analysis, combined with wavelet-based sparsity promotion, to suppress the severe reverberation clutters. The capability to mitigate the reverberation clutters was validated through phantom and in vivo studies. Main Results. In the phantom studies with added reverberation clutters, higher normalized cross-correlation and smaller mean absolute errors were attained as compared to RFM results without the proposed method, demonstrating the capability to reconstruct tissue signals from reverberations. In a pilot patient study, the correlation between ACE and proton density fat fraction (PDFF), a measurement of liver fat by MRI as a reference standard, was investigated. The proposed method showed an improvement of the correlation (coefficient of determination, R = 0.82) as compared with the counterpart without the proposed method (R = 0.69). Significance: The proposed method showed the feasibility of suppressing the reverberation clutters, providing an important basis for the development of a robust ACE with large reverberation clutters.
Collapse
|
5
|
Lin CW, Tsui PH, Lu CH, Hung YH, Tsai MR, Shieh JY, Weng WC. Quantifying Lower Limb Muscle Stiffness as Ambulation Function Declines in Duchenne Muscular Dystrophy with Acoustic Radiation Force Impulse Shear Wave Elastography. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2880-2889. [PMID: 34284931 DOI: 10.1016/j.ultrasmedbio.2021.06.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Revised: 06/11/2021] [Accepted: 06/16/2021] [Indexed: 06/13/2023]
Abstract
Duchenne muscular dystrophy (DMD) is a progressive muscular disease, but validated imaging tools to quantify muscle microstructure alteration as mobility declines are lacking. We aimed to determine the feasibility of using acoustic radiation force impulse shear-wave elastography (ARFI/SWE) in the quantitative assessment of lower limb muscle stiffness in DMD patients. Shear wave velocities (SWVs) of lower limbs were measured in 39 DMD patients and 36 healthy controls aged 3-20 y. Mean SWV values of the controls and of the DMD patients at different ambulatory stages were compared using analysis of variance with Bonferroni correction. The DMD group had increased lower limb muscle stiffness compared with controls. Stiffness of the tibialis anterior and medial gastrocnemius muscle decreased from ambulatory to early non-ambulatory stages, whereas stiffness of the rectus femoris muscle increased from ambulatory to late non-ambulatory stages. We describe how SWV changes in lower limb muscles have the potential to predict ambulatory decline in DMD.
Collapse
Affiliation(s)
- Chia-Wei Lin
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital Hsin-Chu Branch, Hsin-Chu, Taiwan; Department of Physical Medicine and Rehabilitation, National Taiwan University College of Medicine, Taipei, Taiwan; Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan
| | - Po-Hsiang Tsui
- Department of Medical Imaging and Radiological Sciences, Chang Gung University, Taoyuan, Taiwan
| | - Chun-Hao Lu
- Department of Medical Imaging and Radiological Sciences, Chang Gung University, Taoyuan, Taiwan
| | | | - Meng-Ru Tsai
- Department of Physical Medicine and Rehabilitation, National Cheng Kung University Hospital, Tainan, Taiwan
| | - Jeng-Yi Shieh
- Department of Physical Medicine and Rehabilitation, National Taiwan University College of Medicine, Taipei, Taiwan; Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan
| | - Wen-Chin Weng
- Department of Pediatrics, National Taiwan University Hospital, and College of Medicine, National Taiwan University, Taipei, Taiwan; Department of Pediatric Neurology, National Taiwan University Children's Hospital, Taipei, Taiwan.
| |
Collapse
|
6
|
Cloutier G, Destrempes F, Yu F, Tang A. Quantitative ultrasound imaging of soft biological tissues: a primer for radiologists and medical physicists. Insights Imaging 2021; 12:127. [PMID: 34499249 PMCID: PMC8429541 DOI: 10.1186/s13244-021-01071-w] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 08/07/2021] [Indexed: 12/26/2022] Open
Abstract
Quantitative ultrasound (QUS) aims at quantifying interactions between ultrasound and biological tissues. QUS techniques extract fundamental physical properties of tissues based on interactions between ultrasound waves and tissue microstructure. These techniques provide quantitative information on sub-resolution properties that are not visible on grayscale (B-mode) imaging. Quantitative data may be represented either as a global measurement or as parametric maps overlaid on B-mode images. Recently, major ultrasound manufacturers have released speed of sound, attenuation, and backscatter packages for tissue characterization and imaging. Established and emerging clinical applications are currently limited and include liver fibrosis staging, liver steatosis grading, and breast cancer characterization. On the other hand, most biological tissues have been studied using experimental QUS methods, and quantitative datasets are available in the literature. This educational review addresses the general topic of biological soft tissue characterization using QUS, with a focus on disseminating technical concepts for clinicians and specialized QUS materials for medical physicists. Advanced but simplified technical descriptions are also provided in separate subsections identified as such. To understand QUS methods, this article reviews types of ultrasound waves, basic concepts of ultrasound wave propagation, ultrasound image formation, point spread function, constructive and destructive wave interferences, radiofrequency data processing, and a summary of different imaging modes. For each major QUS technique, topics include: concept, illustrations, clinical examples, pitfalls, and future directions.
Collapse
Affiliation(s)
- Guy Cloutier
- Laboratory of Biorheology and Medical Ultrasonics, Centre de recherche du Centre hospitalier de l'Université de Montréal (CRCHUM), 900 St-Denis, Montréal, Québec, H2X 0A9, Canada.
- Department of Radiology, Radio-oncology, and Nuclear Medicine, Université de Montréal, Montréal, Québec, Canada.
- Institute of Biomedical Engineering, Université de Montréal, Montréal, Québec, Canada.
| | - François Destrempes
- Laboratory of Biorheology and Medical Ultrasonics, Centre de recherche du Centre hospitalier de l'Université de Montréal (CRCHUM), 900 St-Denis, Montréal, Québec, H2X 0A9, Canada
| | - François Yu
- Department of Radiology, Radio-oncology, and Nuclear Medicine, Université de Montréal, Montréal, Québec, Canada
- Institute of Biomedical Engineering, Université de Montréal, Montréal, Québec, Canada
- Microbubble Theranostics Laboratory, CRCHUM, Montréal, Québec, Canada
| | - An Tang
- Department of Radiology, Radio-oncology, and Nuclear Medicine, Université de Montréal, Montréal, Québec, Canada
- Department of Radiology, Centre hospitalier de l'Université de Montréal (CHUM), Montréal, Québec, Canada
- Laboratory of Medical Image Analysis, Montréal, CRCHUM, Canada
| |
Collapse
|
7
|
Gong P, Song P, Huang C, Lok UW, Tang S, Zhou C, Yang L, Watt K, Callstrom M, Chen S. Noise Suppression for Ultrasound Attenuation Coefficient Estimation Based on Spectrum Normalization. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2667-2674. [PMID: 33877970 PMCID: PMC8344359 DOI: 10.1109/tuffc.2021.3074293] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Ultrasound attenuation coefficient estimation (ACE) has great diagnostic potential for fatty liver detection and assessment. In a previous study, we proposed a reference phantom-free ACE method, called reference frequency method (RFM), which does not require a calibrated phantom for normalization. The power of each frequency component can be normalized by the power of an adjacent frequency component in the spectrum to cancel system-dependent effects such as focusing and time gain compensation (TGC). RFM demonstrated accurate ACE in both phantom and in in-vivo liver studies. However, our study also showed that the robustness and penetration of RFM were affected by noise in the ACE signals. Here we propose a noise suppression (NS) and a signal-to-noise ratio (SNR) quality control method to reduce the influence of noise on ACE-RFM performance. The proposed methods were tested in harmonic ACE because harmonic imaging is a more frequently used mode than fundamental imaging for abdominal applications. After applying the NS and SNR control methods, the noise-induced bias for attenuation estimation in harmonic ACE was effectively reduced, leading to significantly improved effective penetration depth. The proposed methods directly measure the noise spectrum of the ultrasound system, which can also be adapted to other spectrum-based ACE methods, such as the reference phantom method and the spectra shift method.
Collapse
Affiliation(s)
- Ping Gong
- Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
| | - Pengfei Song
- Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
- Beckman Institute, University of Illinois at Urbana-Champaign, Urbana, IL
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL
| | - Chengwu Huang
- Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
| | - U-Wai Lok
- Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
| | - Shanshan Tang
- Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
| | - Chenyun Zhou
- Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
- Department of Ultrasound, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Lulu Yang
- Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
- Department of Ultrasound, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Kymberly Watt
- Department of Gastroenterology, Mayo Clinic, Rochester, MN, USA
| | - Matthew Callstrom
- Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
| | - Shigao Chen
- Department of Gastroenterology, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
8
|
Gong P, Zhou C, Song P, Huang C, Lok UW, Tang S, Watt K, Callstrom M, Chen S. Ultrasound Attenuation Estimation in Harmonic Imaging for Robust Fatty Liver Detection. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:3080-3087. [PMID: 32773254 PMCID: PMC7534411 DOI: 10.1016/j.ultrasmedbio.2020.07.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 06/22/2020] [Accepted: 07/09/2020] [Indexed: 02/05/2023]
Abstract
Accurate detection of liver steatosis is important for liver disease management. Ultrasound attenuation coefficient estimation (ACE) has great potential in quantifying liver fat content. The commonly used ACE methods (e.g., spectral shift methods, reference phantom methods) assume linear tissue response to ultrasound and were developed in fundamental imaging. However, fundamental imaging may be vulnerable to reverberation clutters introduced by the body wall. The clutters superimposed on liver echoes may bias the attenuation estimation. Here we propose a new ACE technique, the reference frequency method (RFM), in harmonic imaging to mitigate the reverberation bias. The accuracy of harmonic RFM was validated through a phantom study. In a pilot patient study, harmonic RFM performed more robustly in vivo compared with fundamental RFM, illustrating the potential of ACE in harmonic imaging.
Collapse
Affiliation(s)
- Ping Gong
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Chenyun Zhou
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA; Department of Ultrasound, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Pengfei Song
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA; Beckman Institute, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA; Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Chengwu Huang
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - U-Wai Lok
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Shanshan Tang
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Kymberly Watt
- Department of Gastroenterology, Mayo Clinic, Rochester, Minnesota, USA
| | | | - Shigao Chen
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
| |
Collapse
|
9
|
Kothawala AA, Baskaran D, Arunachalam K, Thittai AK. Ultrasound-Based Regularized Log Spectral Difference Method For Monitoring Microwave Hyperthermia. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:6387-6390. [PMID: 31947304 DOI: 10.1109/embc.2019.8857139] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The feasibility of using normalized cumulative difference attenuation (NCDA) map for tracking the spatial and temporal evolution of temperature during microwave hyperthermia experiment on in-vitro phantoms is explored in this study. The NCDA maps were estimated from the beamformed ultrasound radio frequency (RF) data using a regularized log spectral difference (RLSD) technique. The NCDA maps were estimated at different time instants for the entire period of the experiment. The contour maps of the NCDA and the ground truth temperature map, obtained using an infra-red(IR) thermal camera corresponding to the ultrasound imaging plane, showed that NCDA was able to locate the axial and lateral co-ordinates of the hotspot with the error of <; 1.5 mm axially and <; 0.1 mm laterally. The error in the estimated hotspot area was less than 8 %. This preliminary in-vitro study suggests that NCDA maps estimated using RLSD may have potential in evaluating the spatio-temporal evolution of temperature and may help in the development of ultrasound-based image-guided temperature monitoring system for microwave hyperthermia.
Collapse
|
10
|
Gong P, Song P, Huang C, Trzasko J, Chen S. System-Independent Ultrasound Attenuation Coefficient Estimation Using Spectra Normalization. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:867-875. [PMID: 30843826 PMCID: PMC6508689 DOI: 10.1109/tuffc.2019.2903010] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Ultrasound attenuation coefficient estimation (ACE) has diagnostic potential for clinical applications such as differentiating tumors and quantifying fat content in the liver. The two commonly used ACE methods in the ultrasound array imaging system are the spectral shift method and the reference-phantom-based methods. The spectra shift method estimates the central frequency downshift along depth, whereas the reference-phantom-based methods use a well-calibrated phantom to cancel system dependent effects in attenuation estimation. In this study, we propose a novel system-independent ACE technique based on spectra normalization of different frequencies. This technique does not require a reference phantom for normalization. The power of each frequency component is normalized by the power of an adjacent frequency component in the spectrum to cancel system-dependent effects, such as focusing and time gain compensation (TGC). This method is referred to as the reference frequency method (RFM), and its performance has been evaluated in phantoms and in vivo liver studies. The RFM technique can be applied to various transducer geometries (e.g., linear or curved arrays) with different beam patterns (e.g., focused or unfocused).
Collapse
|
11
|
Weng WC, Lin CW, Shen HC, Chang CC, Tsui PH. Instantaneous frequency as a new approach for evaluating the clinical severity of Duchenne muscular dystrophy through ultrasound imaging. ULTRASONICS 2019; 94:235-241. [PMID: 30287072 DOI: 10.1016/j.ultras.2018.09.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 08/24/2018] [Accepted: 09/09/2018] [Indexed: 06/08/2023]
Abstract
Duchenne muscular dystrophy (DMD) results in loss of ambulation for the patients. Ultrasound attenuation correlates with fat content in muscles, resulting in changes in signal frequency. The Hilbert-Huang transform (HHT) allows time-frequency analysis with high time-frequency resolution. This study explored the feasibility of using the instantaneous frequency (IF) obtained from the HHT to diagnose the walking function of patients with DMD. Eighty-five participants (12 control and 73 patients with DMD) underwent a standard-care ultrasound examination of the gastrocnemius to acquire raw image data for ultrasound B-mode and IF calculations, which were compared with the DMD stage using Pearson correlation and receiver operating characteristic (ROC) curve analyses. With increasing DMD stage, the median IF decreased from 7.25 to 7.01 MHz (the correlation coefficient r = -0.73; the probability value p < 0.0001). The area under the ROC curve was 0.97 when using ultrasound IF to discriminate between ambulatory and nonambulatory patients (accuracy: 91.76%; sensitivity: 93.75%; and specificity: 90.57%). The study reveals that ultrasound IF has great potential in DMD evaluation and management.
Collapse
Affiliation(s)
- Wen-Chin Weng
- Department of Pediatrics, National Taiwan University Hospital, and College of Medicine, National Taiwan University, Taipei, Taiwan; Department of Pediatrics, College of Medicine, National Taiwan University, Taipei, Taiwan; Department of Pediatric Neurology, National Taiwan University Children's Hospital, Taipei, Taiwan
| | - Chia-Wei Lin
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital Hsin-Chu Branch, Hsin-Chu, Taiwan
| | - Hui-Chung Shen
- Institute of Applied Mechanics, National Taiwan University, Taipei, Taiwan
| | - Chien-Cheng Chang
- Institute of Applied Mechanics, National Taiwan University, Taipei, Taiwan.
| | - Po-Hsiang Tsui
- Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan; Medical Imaging Research Center, Institute for Radiological Research, Chang Gung University and Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan.
| |
Collapse
|
12
|
Khan MHR, Hasan MK. Attenuation estimation of soft tissue with reference-free minimization of system effects. Biomed Signal Process Control 2019. [DOI: 10.1016/j.bspc.2019.01.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
13
|
Ilyina N, Hermans J, Verboven E, Van Den Abeele K, D'Agostino E, D'hooge J. Attenuation estimation by repeatedly solving the forward scattering problem. ULTRASONICS 2018; 84:201-209. [PMID: 29156300 DOI: 10.1016/j.ultras.2017.10.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Revised: 07/11/2017] [Accepted: 10/09/2017] [Indexed: 06/07/2023]
Abstract
Estimation of the attenuation is important in medical ultrasound not only for correct time-gain compensation but also for tissue characterization. In this paper, the feasibility of a new method for attenuation estimation is tested. The proposed method estimates the attenuation by repeatedly solving the forward wave propagation problem and matching the simulated signals to the measured ones. This approach allows avoiding common assumptions made by other methodologies and potentially allows to account and correct for other acoustic effects that may bias the attenuation estimate. The performance of the method was validated on simulated data and on data recorded in tissue mimicking phantoms with known attenuation properties, and was compared to the spectral-shift and spectral-difference methods. Simulation results showed the different methods to have good accuracy when noise-free signals were considered (the average relative error of the attenuation estimation did not exceed 15%). However, the accuracy of the conventional methods decreased rapidly in the presence of measurement noise and varying scatterer concentration, while the relative error of the proposed method remained below 15%. Furthermore, the proposed method outperformed conventional attenuation estimators in the experimental phantom study, where its average error was 8%, while the average error of the spectral-shift and spectral-difference methods was 26% and 32%, respectively. In summary, these findings demonstrate the feasibility of the proposed approach and motivate us to refine the method for solving more general problems.
Collapse
Affiliation(s)
- Natalia Ilyina
- Dept. of Cardiovascular Sciences - KU Leuven, Leuven, Belgium; Belgian Nuclear Research Centre, SCK·CEN, Mol, Belgium.
| | | | - Erik Verboven
- Dept. of Physics, KU Leuven Kulak, Kortrijk, Belgium
| | | | | | - Jan D'hooge
- Dept. of Cardiovascular Sciences - KU Leuven, Leuven, Belgium
| |
Collapse
|
14
|
Samimi K, White JK, Brace CL, Varghese T. Monitoring Microwave Ablation of Ex Vivo Bovine Liver Using Ultrasonic Attenuation Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:1441-1451. [PMID: 28454843 PMCID: PMC5450944 DOI: 10.1016/j.ultrasmedbio.2017.03.010] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Revised: 03/16/2017] [Accepted: 03/17/2017] [Indexed: 05/10/2023]
Abstract
Thermal ablation of soft tissue changes the tissue microstructure and, consequently, induces changes in its acoustic properties. Although B-mode ultrasound provides high-resolution and high-frame-rate images of ablative therapeutic procedures, it is not particularly effective at delineating boundaries of ablated regions because of poor contrast in echogenicity between ablated and surrounding normal tissue. Quantitative ultrasound techniques can provide quantitative estimates of acoustic properties, such as backscatter and attenuation coefficients, and differentiate ablated and unablated regions more effectively, with the potential for monitoring minimally invasive thermal therapies. In this study, a previously introduced attenuation estimation method was used to create quantitative attenuation coefficient maps for 11 microwave ablation procedures performed on refrigerated ex vivo bovine liver. The attenuation images correlate well with the pathologic images of the ablated region. The mean attenuation coefficient for regions of interest drawn inside and outside the ablated zones were 0.9 (±0.2) and 0.45 (±0.15) dB/cm/MHz, respectively. These estimates agree with reported values in the literature and establish the usefulness of non-invasive attenuation imaging for monitoring therapeutic procedures in the liver.
Collapse
Affiliation(s)
- Kayvan Samimi
- Department of Electrical and Computer Engineering, College of Engineering, University of Wisconsin, Madison, Wisconsin, USA.
| | - James K White
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Christopher L Brace
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Tomy Varghese
- Department of Electrical and Computer Engineering, College of Engineering, University of Wisconsin, Madison, Wisconsin, USA; Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| |
Collapse
|
15
|
Samimi K, Varghese T. Lower Bound on Estimation Variance of the Ultrasonic Attenuation Coefficient Using the Spectral-Difference Reference-phantom Method. ULTRASONIC IMAGING 2017; 39:151-171. [PMID: 28425388 PMCID: PMC5407315 DOI: 10.1177/0161734616674329] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Ultrasonic attenuation is one of the primary parameters of interest in Quantitative Ultrasound (QUS). Non-invasive monitoring of tissue attenuation can provide valuable diagnostic and prognostic information to the physician. The Reference Phantom Method (RPM) was introduced as a way of mitigating some of the system-related effects and biases to facilitate clinical QUS applications. In this paper, under the assumption of diffuse scattering, a probabilistic model of the backscattered signal spectrum is used to derive a theoretical lower bound on the estimation variance of the attenuation coefficient using the Spectral-Difference RPM. The theoretical lower bound is compared to simulated and experimental attenuation estimation statistics in tissue-mimicking (TM) phantoms. Estimation standard deviation (STD) of the sample attenuation in a region of interest (ROI) of the TM phantom is measured for various combinations of processing parameters, including Radio-Frequency (RF) data block length (i.e., window length) from 3 to 17 mm, RF data block width from 10 to 100 A-lines, and number of RF data blocks per attenuation estimation ROI from 3 to 10. In addition to the Spectral-Difference RPM, local attenuation estimation for simulated and experimental data sets was also performed using a modified implementation of the Spectral Fit Method (SFM). Estimation statistics of the SFM are compared to theoretical variance predictions from the literature.1 Measured STD curves are observed to lie above the theoretical lower bound curves, thus experimentally verifying the validity of the derived bounds. This theoretical framework benefits tissue characterization efforts by isolating processing parameter ranges that could provide required precision levels in estimation of the ultrasonic attenuation coefficient using Spectral Difference methods.
Collapse
Affiliation(s)
- Kayvan Samimi
- Department of Electrical and Computer Engineering, College of Engineering, University of Wisconsin–Madison, Madison, WI, USA
| | - Tomy Varghese
- Department of Electrical and Computer Engineering, College of Engineering, University of Wisconsin–Madison, Madison, WI, USA
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, University of Wisconsin–Madison, Madison, WI, USA
| |
Collapse
|
16
|
Klimonda Z, Postema M, Nowicki A, Litniewski J. Tissue Attenuation Estimation by Mean Frequency Downshift and Bandwidth Limitation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1107-1115. [PMID: 27254862 DOI: 10.1109/tuffc.2016.2574399] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Attenuation of ultrasound in tissue can be estimated from the propagating pulse center frequency downshift. This method assumes that the envelope of the emitted pulse can be approximated by a Gaussian function and that the attenuation linearly depends on frequency. The resulting downshift of the mean frequency depends not only on attenuation but also on pulse bandwidth and propagation distance. This kind of approach is valid for narrowband pulses and shallow penetration depth. However, for short pulses and deep penetration, the frequency downshift is rather large and the received spectra are modified by the limited bandwidth of the receiving system. In this paper, the modified formula modeling the mean frequency of backscattered echoes is presented. The equation takes into account the limitation of the bandwidth due to bandpass filtration of the received echoes. This approach was applied to simulate the variation of the mean frequency of the pulse propagating for both weakly and strongly attenuating media and for narrowband and wideband pulses. The behavior of both the standard and modified estimates of attenuation has been validated using RF data from a tissue-mimicking phantom. The ultrasound attenuation of the phantom, determined with a corrected equation, was close to its true value, while the result obtained using the original formula was lower by as much as 50% at a depth of 8 cm.
Collapse
|
17
|
Samimi K, Varghese T. Optimum Diffraction-Corrected Frequency-Shift Estimator of the Ultrasonic Attenuation Coefficient. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:691-702. [PMID: 26960224 PMCID: PMC5011035 DOI: 10.1109/tuffc.2016.2538719] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The ultrasonic attenuation coefficient is an important parameter that has been studied extensively in Quantitative Ultrasound and Tissue Characterization. There are various methods described in the literature that estimate this parameter by measuring either spectral difference (i.e., decay) or spectral shift of the backscattered echo signal. Under ideal conditions, i.e., in the absence of abrupt changes in tissue backscattering, Spectral Difference methods can produce estimates with high accuracy and precision. On the other hand, diffraction-corrected Spectral Shift methods (e.g., the Hybrid method) are better suited for application in practical settings using clinical ultrasound scanners. However, current Spectral Shift methods use inefficient frequency shift estimators that ultimately degrade the quality of attenuation coefficient estimates. In this paper, a probabilistic model of the backscattered radiofrequency (RF) echo is used to derive the Cramér-Rao lower bound (CRLB) on estimation variance of the spectral centroid. Next, an efficient correlation-based shift estimator is presented that achieves the CRLB. Used in conjunction with a well-characterized reference phantom to correct for diffraction and other system-related effects, this estimator greatly improves the accuracy and precision of Spectral- Shift attenuation estimation. A theoretical analysis of this method is provided, and its performance is quantitatively compared with that of the Hybrid method using simulated and experimental phantom studies. A minimum of 3-fold reduction in the standard deviation of attenuation coefficient estimates is observed using the new method.
Collapse
|