1
|
Magneto-Mechanical Approach in Biomedicine: Benefits, Challenges, and Future Perspectives. Int J Mol Sci 2022; 23:ijms231911134. [PMID: 36232435 PMCID: PMC9569787 DOI: 10.3390/ijms231911134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 09/14/2022] [Accepted: 09/17/2022] [Indexed: 11/16/2022] Open
Abstract
The magneto-mechanical approach is a powerful technique used in many different applications in biomedicine, including remote control enzyme activity, cell receptors, cancer-selective treatments, mechanically-activated drug releases, etc. This approach is based on the use of a combination of magnetic nanoparticles and external magnetic fields that have led to the movement of such nanoparticles with torques and forces (enough to change the conformation of biomolecules or even break weak chemical bonds). However, despite many theoretical and experimental works on this topic, it is difficult to predict the magneto-mechanical effects in each particular case, while the important results are scattered and often cannot be translated to other experiments. The main reason is that the magneto-mechanical effect is extremely sensitive to changes in any parameter of magnetic nanoparticles and the environment and changes in the parameters of the applied magnetic field. Thus, in this review, we (1) summarize and propose a simplified theoretical explanation of the main factors affecting the efficiency of the magneto-mechanical approach; (2) discuss the nature of the MNP-mediated mechanical forces and their order of magnitude; (3) show some of the main applications of the magneto-mechanical approach in the control over the properties of biological systems.
Collapse
|
2
|
Cebrecos A, Jimenez N, Tarazona R, Company M, Benlloch JM, Camarena F. Characterization of Viscoelastic Media Combining Ultrasound and Magnetic-Force Induced Vibrations on an Embedded Soft Magnetic Sphere. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:3540-3548. [PMID: 34270421 DOI: 10.1109/tuffc.2021.3097883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
We report a method to locally assess the complex shear modulus of a viscoelastic medium. The proposed approach is based on the application of a magnetic force to a millimeter-sized steel sphere embedded in the medium and the subsequent monitoring of its dynamical response. A coil is used to create a magnetic field inducing the displacement of the sphere located inside a gelatin phantom. Then, a phased-array system using 3 MHz ultrasound probe operating in pulse-echo mode is used to track the displacement of the sphere. Experiments were conducted on several samples and repeated as a function of phantom temperature. The dynamic response of the sphere measured experimentally is in good agreement with Kelvin-Voigt theory. Since the magnetic force is not affected by weak diamagnetic media, our proposal results in an accurate estimation of the force acting on the inclusion. Consequently, the estimated viscoelastic parameters show excellent robustness and the elastic modulus agrees with the measurements using a quasi-static indentation method, obtaining errors below 10% in the whole temperature range. The use of the macroscopic inclusion limits the direct application of this method in a biomedical context, but it provides a robust estimation of the elastic modulus that can be used for material characterization in industrial applications.
Collapse
|
3
|
Józefczak A, Kaczmarek K, Bielas R. Magnetic mediators for ultrasound theranostics. Theranostics 2021; 11:10091-10113. [PMID: 34815806 PMCID: PMC8581415 DOI: 10.7150/thno.62218] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Accepted: 10/02/2021] [Indexed: 12/11/2022] Open
Abstract
The theranostics paradigm is based on the concept of combining therapeutic and diagnostic modalities into one platform to improve the effectiveness of treatment. Combinations of multiple modalities provide numerous medical advantages and are enabled by nano- and micron-sized mediators. Here we review recent advancements in the field of ultrasound theranostics and the use of magnetic materials as mediators. Several subdisciplines are described in detail, including controlled drug delivery and release, ultrasound hyperthermia, magneto-ultrasonic heating, sonodynamic therapy, magnetoacoustic imaging, ultrasonic wave generation by magnetic fields, and ultrasound tomography. The continuous progress and improvement in theranostic materials, methods, and physical computing models have created undeniable possibilities for the development of new approaches. We discuss the prospects of ultrasound theranostics and possible expansions of other studies to the theranostic context.
Collapse
Affiliation(s)
- Arkadiusz Józefczak
- Chair of Acoustics, Faculty of Physics, Adam Mickiewicz University in Poznań, Uniwersytetu Poznańskiego 2, 61-614 Poznań, Poland
| | - Katarzyna Kaczmarek
- Department of Biomedical Engineering, Faculty of Engineering, University of Strathclyde, Wolfson Centre, 106 Rottenrow, Glasgow, United Kingdom
| | - Rafał Bielas
- Chair of Acoustics, Faculty of Physics, Adam Mickiewicz University in Poznań, Uniwersytetu Poznańskiego 2, 61-614 Poznań, Poland
| |
Collapse
|
4
|
Hadadian Y, Uliana JH, Carneiro AAO, Pavan TZ. A Novel Theranostic Platform: Integration of Magnetomotive and Thermal Ultrasound Imaging With Magnetic Hyperthermia. IEEE Trans Biomed Eng 2020; 68:68-77. [PMID: 32356735 DOI: 10.1109/tbme.2020.2990873] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE Nanotheranostic systems integrate therapeutic and diagnostic procedures using nanotechnology. This type of approach has enabled the development of methods for early detection and treatment of different pathologies. Magnetic hyperthermia (MH) has been proposed as an alternative or complementary method of cancer therapy. However, challenges such as delivering and localizing the magnetic nanoparticles (MNPs) within tissues and monitoring the temperature during the treatment hinder this technique to be effectively translated into a clinical routine. Therefore, in this study a theranostic platform has been proposed and examined to address two main issues, localizing MNPs and real-time temperature monitoring, for preclinical MH. METHODS The system integrates magnetomotive (MMUS) and thermal ultrasound imaging with MH. An ultrasound device was used to acquire MMUS images to detect MNPs, and ultrasound thermometry to monitor the temperature. This platform was designed such that a single coil generated the magnetic field for MMUS and MH. The feasibility of the system was examined using a tissue mimicking phantom containing an inclusion filled with zinc substituted magnetite NPs. RESULTS These MNPs were effectively used as contrast agent for MMUS and to generate heat during MH. In addition to localizing MNPs, real-time two-dimensional temperature maps were obtained with substantial concordance (ρc > 0.97) with invasive measurements using fiber optic thermometer. The heating rate was proportional to the displacements in MMUS (r = 0.92). CONCLUSION Ultrasound thermometry was successfully used to monitor the temperature during MH. In addition, it was shown that acquiring MMUS images prior to MH can qualitatively predict the temperature distribution of the MNP-laden regions.
Collapse
|
5
|
Sjöstrand S, Evertsson M, Jansson T. Magnetomotive Ultrasound Imaging Systems: Basic Principles and First Applications. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:2636-2650. [PMID: 32753288 DOI: 10.1016/j.ultrasmedbio.2020.06.014] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Revised: 04/29/2020] [Accepted: 06/19/2020] [Indexed: 06/11/2023]
Abstract
This review discusses magnetomotive ultrasound, which is an emerging technique that uses superparamagnetic iron oxide nanoparticles as a contrast agent. The key advantage of using nanoparticle-based contrast agents is their ability to reach extravascular targets, whereas commercial contrast agents for ultrasound comprise microbubbles confined to the blood stream. This also extends possibilities for molecular imaging, where the contrast agent is labeled with specific targeting molecules (e.g., antibodies) so that pathologic tissue may be visualized directly. The principle of action is that an external time-varying magnetic field acts to displace the nanoparticles lodged in tissue and thereby their immediate surrounding. This movement is then detected with ultrasound using frequency- or time-domain analysis of echo data. As a contrast agent already approved for magnetic resonance imaging (MRI) by the US Food and Drug Administration, there is a shorter path to clinical translation, although safety studies of magnetomotion are necessary, especially if particle design is altered to affect biodistribution or signal strength. The external modulated magnetic field may be generated by electromagnets, permanent magnets, or a combination of the two. The induced nanoparticle motion may also reveal mechanical material properties of tissue, healthy or diseased, one of several interesting potential future aspects of the technique.
Collapse
Affiliation(s)
- Sandra Sjöstrand
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Maria Evertsson
- Department of Clinical Sciences Lund/Biomedical Engineering, Lund University, Lund, Sweden
| | - Tomas Jansson
- Department of Clinical Sciences Lund/Biomedical Engineering, Lund University, Lund, Sweden; Clinical Engineering Skåne, Digitalisering IT/MT, Region Skåne, Lund, Sweden.
| |
Collapse
|
6
|
Arsalani S, Arsalani S, Hadadian Y, Sampaio DRT, Baffa O, Pavan TZ, Carneiro AAO. The effect of magnetization of natural rubber latex-coated magnetite nanoparticles on shear wave dispersion magneto-motive ultrasound. ACTA ACUST UNITED AC 2019; 64:215019. [DOI: 10.1088/1361-6560/ab4693] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
7
|
Evertsson M, Kjellman P, Cinthio M, Andersson R, Tran TA, In't Zandt R, Grafström G, Toftevall H, Fredriksson S, Ingvar C, Strand SE, Jansson T. Combined Magnetomotive ultrasound, PET/CT, and MR imaging of 68Ga-labelled superparamagnetic iron oxide nanoparticles in rat sentinel lymph nodes in vivo. Sci Rep 2017; 7:4824. [PMID: 28684867 PMCID: PMC5500498 DOI: 10.1038/s41598-017-04396-z] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2017] [Accepted: 05/12/2017] [Indexed: 12/31/2022] Open
Abstract
Current methods for intra-surgical guidance to localize metastases at cancer surgery are based on radioactive tracers that cause logistical challenges. We propose the use of a novel ultrasound-based method, magnetomotive ultrasound (MMUS) imaging that employ a nanoparticle-based contrast agent that also may be used for pre-operative PET/MRI imaging. Since MMUS is radiation free, this eliminates the dependence between pre- and intra-operative imaging and the radiation exposure for the surgical staff. This study investigates a hypothetical clinical scenario of pre-operative PET imaging, combined with intra-operative MMUS imaging, implemented in a sentinel lymph node (SLN) rat model. At one-hour post injection of 68Ga-labelled magnetic nanoparticles, six animals were imaged with combined PET/CT. After two or four days, the same animals were imaged with MMUS. In addition, ex-vivo MRI was used to evaluate the amount of nanoparticles in each single SLN. All SLNs were detectable by PET. Four out of six SLNs could be detected with MMUS, and for these MMUS and MRI measurements were in close agreement. The MRI measurements revealed that the two SLNs undetectable with MMUS contained the lowest nanoparticle concentrations. This study shows that MMUS can complement standard pre-operative imaging by providing bedside real-time images with high spatial resolution.
Collapse
Affiliation(s)
- Maria Evertsson
- Department of Biomedical Engineering, Faculty of Engineering LTH at Lund University, Lund, Sweden.
| | - Pontus Kjellman
- Lund University, Faculty of Medicine, Department of Clinical Sciences Lund, Medical Radiation Physics, Lund, Sweden
| | - Magnus Cinthio
- Department of Biomedical Engineering, Faculty of Engineering LTH at Lund University, Lund, Sweden
| | | | - Thuy A Tran
- Lund University Bioimaging Center, Lund University, Lund, Sweden.,Lund University, Faculty of Medicine, Department of Clinical Sciences Lund, Division of Oncology-Pathology, Lund, Sweden
| | - Rene In't Zandt
- Lund University Bioimaging Center, Lund University, Lund, Sweden
| | - Gustav Grafström
- Lund University Bioimaging Center, Lund University, Lund, Sweden
| | | | | | | | - Sven-Erik Strand
- Lund University, Faculty of Medicine, Department of Clinical Sciences Lund, Medical Radiation Physics, Lund, Sweden
| | - Tomas Jansson
- Medical Services, Skåne University Hospital, Lund, Sweden.,Lund University, Faculty of Medicine, Department of Clinical Sciences Lund, Biomedical Engineering, Lund, Sweden
| |
Collapse
|
8
|
Almeida TWJ, Sampaio DRT, Bruno AC, Pavan TZ, Carneiro AAO. Comparison between shear wave dispersion magneto motive ultrasound and transient elastography for measuring tissue-mimicking phantom viscoelasticity. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2015; 62:2138-2145. [PMID: 26670853 DOI: 10.1109/tuffc.2015.007353] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Several methods have been developed over the last several years to analyze the mechanical properties of soft tissue. Elastography, for example, was proposed to evaluate soft tissue stiffness in an attempt to reduce the need for invasive procedures, such as breast biopsies; however, its qualitative nature and the fact that it is operator-dependent have proven to be limitations of the technique. Quantitative shearwave- based techniques have been proposed to obtain information about tissue stiffness independent of the operator. This paper describes shear wave dispersion magnetomotive ultrasound (SDMMUS), a new shear-wave-based method in which a viscoelastic medium labeled with iron oxide nanoparticles is displaced by an external tone burst magnetic field. As in magnetomotive ultrasound (MMUS), SDMMUS uses ultrasound to detect internal mechanical vibrations induced by the interaction between a magnetic field and magnetic nanoparticles. These vibrations generated shear waves that were evaluated to estimate the viscoelastic properties of tissue-mimicking phantoms. These phantoms were manufactured with different concentrations of gelatin and labeled with iron oxide nanoparticles. The elasticity and viscosity obtained with SDMMUS agreed well with the results obtained by traditional ultrasound-based transient elastography.
Collapse
|