1
|
Choi W, Park B, Choi S, Oh D, Kim J, Kim C. Recent Advances in Contrast-Enhanced Photoacoustic Imaging: Overcoming the Physical and Practical Challenges. Chem Rev 2023. [PMID: 36642892 DOI: 10.1021/acs.chemrev.2c00627] [Citation(s) in RCA: 36] [Impact Index Per Article: 36.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
For decades now, photoacoustic imaging (PAI) has been investigated to realize its potential as a niche biomedical imaging modality. Despite its highly desirable optical contrast and ultrasonic spatiotemporal resolution, PAI is challenged by such physical limitations as a low signal-to-noise ratio (SNR), diminished image contrast due to strong optical attenuation, and a lower-bound on spatial resolution in deep tissue. In addition, contrast-enhanced PAI has faced practical limitations such as insufficient cell-specific targeting due to low delivery efficiency and difficulties in developing clinically translatable agents. Identifying these limitations is essential to the continuing expansion of the field, and substantial advances in developing contrast-enhancing agents, complemented by high-performance image acquisition systems, have synergistically dealt with the challenges of conventional PAI. This review covers the past four years of research on pushing the physical and practical challenges of PAI in terms of SNR/contrast, spatial resolution, targeted delivery, and clinical application. Promising strategies for dealing with each challenge are reviewed in detail, and future research directions for next generation contrast-enhanced PAI are discussed.
Collapse
Affiliation(s)
- Wonseok Choi
- Department of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, Graduate School of Artificial Intelligence, and Medical Device Innovation Center, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang37673, Republic of Korea
| | - Byullee Park
- Department of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, Graduate School of Artificial Intelligence, and Medical Device Innovation Center, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang37673, Republic of Korea
| | - Seongwook Choi
- Department of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, Graduate School of Artificial Intelligence, and Medical Device Innovation Center, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang37673, Republic of Korea
| | - Donghyeon Oh
- Department of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, Graduate School of Artificial Intelligence, and Medical Device Innovation Center, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang37673, Republic of Korea
| | - Jongbeom Kim
- Department of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, Graduate School of Artificial Intelligence, and Medical Device Innovation Center, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang37673, Republic of Korea
| | - Chulhong Kim
- Department of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, Graduate School of Artificial Intelligence, and Medical Device Innovation Center, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang37673, Republic of Korea
| |
Collapse
|
2
|
Chen W, Zhang Q, Liu J, Lei S, Li Y, Huang J, Guo L, Zheng H, Wu D, Ma T. Design and Fabrication of a High-Frequency Microconvex Array Transducer for Small Animals Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1943-1951. [PMID: 35073263 DOI: 10.1109/tuffc.2022.3146309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
High-frequency convex array transducer, featuring both high spatial resolution and wide field of view, has been successfully developed for ophthalmic imaging. To further expand its application range to small animals' imaging, this work develops a high-frequency microconvex array transducer possessing smaller aperture size and wider scanning angle. This transducer featured 128 array elements arranged in a curvilinear 2-2 piezoelectric composite configuration, yielding a maximum view angle of 97.8°. The array was composed of two front matching layers, a nonconductive backing layer, and a customized flexible circuit that electrically connected array elements to coaxial cables. The center frequency and the -6-dB fractional bandwidth were about 18.14 MHz and 69.15%, respectively. The image of a tungsten wire phantom resulted in approximately 62.9- [Formula: see text] axial resolution and 121.3- [Formula: see text] lateral resolution. The image of the whole kidney of a rat as well as its internal arteries was acquired in vivo, demonstrating the imaging capability of the proposed high-frequency microconvex array transducers for small animals' imaging applications.
Collapse
|
3
|
Kim H, Lee H, Kim H, Chang JH. Elimination of Nontargeted Photoacoustic Signals for Combined Photoacoustic and Ultrasound Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:1593-1604. [PMID: 33259296 DOI: 10.1109/tuffc.2020.3041634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
As a molecular imaging modality, photoacoustic (PA) imaging has been in the spotlight because it can provide an optical contrast image of physiological information and a relatively deep imaging depth. However, its sensitivity is limited despite the use of exogenous contrast agents due to the background PA signals generated from nontargeted absorbers, such as blood and boundaries between different biological tissues. In addition, clutter artifacts generated in both in-plane and out-of-plane imaging region degrade the sensitivity of PA imaging. We propose a method to eliminate the nontargeted PA signals. For this study, we used a dual-modal ultrasound (US)-PA contrast agent that is capable of generating both the backscattered US and PA signals in response to the transmitted US and irradiated light, respectively. The US images of the contrast agents are used to construct a masking image that contains the location information about the target site and is applied to the PA image acquired after contrast agent injection. In vitro and in vivo experimental results demonstrated that the masking image constructed using the US images makes it possible to completely remove nontargeted PA signals. The proposed method can be used to enhance the clear visualization of the target area in PA images.
Collapse
|
4
|
Jang J, Kim J, Lee HJ, Chang JH. Transrectal Ultrasound and Photoacoustic Imaging Probe for Diagnosis of Prostate Cancer. SENSORS 2021; 21:s21041217. [PMID: 33572287 PMCID: PMC7915711 DOI: 10.3390/s21041217] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 02/05/2021] [Accepted: 02/05/2021] [Indexed: 12/27/2022]
Abstract
A combined transrectal ultrasound and photoacoustic (TRUS-PA) imaging probe was developed for the clear visualization of morphological changes and microvasculature distribution in the prostate, as this is required for accurate diagnosis and biopsy. The probe consisted of a miniaturized 128-element 7 MHz convex array transducer with 134.5° field-of-view (FOV), a bifurcated optical fiber bundle, and two optical lenses. The design goal was to make the size of the TRUS-PA probe similar to that of general TRUS probes (i.e., about 20 mm), for the convenience of the patients. New flexible printed circuit board (FPCB), acoustic structure, and optical lens were developed to meet the requirement of the probe size, as well as to realize a high-performance TRUS-PA probe. In visual assessment, the PA signals obtained with the optical lens were 2.98 times higher than those without the lens. Moreover, the in vivo experiment with the xenograft BALB/c (Albino, Immunodeficient Inbred Strain) mouse model showed that TRUS-PA probe was able to acquire the entire PA image of the mouse tight behind the porcine intestine about 25 mm depth. From the ex vivo and in vivo experimental results, it can be concluded that the developed TRUS-PA probe is capable of improving PA image quality, even though the TRUS-PA probe has a cross-section size and an FOV comparable to those of general TRUS probes.
Collapse
Affiliation(s)
- Jihun Jang
- Department of Electronic Engineering, Sogang University, Seoul 04107, Korea;
| | - Jinwoo Kim
- Department of Information and Communnication Engineering, Daegu Gyeongbuk Institute of Science and Technology, Daegu 42988, Korea;
| | - Hak Jong Lee
- Department of Radiology, Seoul National University of Bundang Hospital, Seongnam-si 13620, Korea;
| | - Jin Ho Chang
- Department of Information and Communnication Engineering, Daegu Gyeongbuk Institute of Science and Technology, Daegu 42988, Korea;
- Correspondence: ; Tel.: +82-53-785-6330
| |
Collapse
|
5
|
Abstract
Abstract
Purpose
Photoacoustic (PA) microscopy has emerged as a useful tool in biomedical imaging applications such as visualization of microvasculature and hemoglobin oxygen saturation, single-cell, and label-free imaging of organs including cancer. Since the ultrasound transducers used for PA signal detection are not optically transparent, the integration of optical and acoustic modules for coaxial alignment of laser and acoustic beam fields in PA microscopy is complex and costly.
Methods
Here, we report a recently developed optically transparent focused transducer for combined PA and ultrasound (US) microscopy. All the acoustic layers including the acoustic lens are optically transparent, enabling simple integration of optical and acoustic modules for both imaging modalities.
Results
The mean light transmittance of the transducer’s backing layer and acoustic lens and of the transducer itself were measured at 92%, 83%, and 66%, respectively. Results from in vitro and in vivo experiments demonstrated the transducer to be suitable for both US and PA imaging.
Conclusions
The results of this study represent a step toward efficient construction of probes for combined PA and US microscopy.
Collapse
|
6
|
A 40-MHz Ultrasound Transducer with an Angled Aperture for Guiding Percutaneous Revascularization of Chronic Total Occlusion: A Feasibility Study. SENSORS 2018; 18:s18114079. [PMID: 30469448 PMCID: PMC6263984 DOI: 10.3390/s18114079] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Revised: 11/13/2018] [Accepted: 11/18/2018] [Indexed: 12/13/2022]
Abstract
Complete blockage of a coronary artery, called chronic total occlusion (CTO), frequently occurs due to atherosclerosis. To reopen the obstructed blood vessels with a stent, guidewire crossing is performed with the help of angiography that can provide the location of CTO lesions and the image of guidewire tip. Since angiography is incapable of imaging inside a CTO lesion, the surgeons are blind during guidewire crossing. For this reason, the success rate of guidewire crossing relies upon the proficiency of the surgeon, which is considerably reduced from 69.0% to 32.5% if extensive calcification, not penetrated by a guidewire, exists in CTO lesions. In this paper, a recently developed 40-MHz forward-looking intravascular ultrasound (FL–IVUS) transducer to visualize calcification within CTO lesions is reported. This transducer consists of a single element angled aperture and a guidewire passage. The aperture is spherically deformed to have a focal length of 3 mm in order to improve spatial resolution of FL–IVUS images. The angle between the beam direction and the axis of rotation is designed to be 30° to effectively visualize calcification within a CTO lesion as well as the blood vessel wall. The experimental results demonstrated that the developed FL–IVUS transducer facilitates visualization of calcification within CTO lesions and makes it possible to help the surgeon make decisions about whether to push the guidewire in order to cross the lesion or to change the surgical procedure.
Collapse
|