1
|
Masoumi MH, Kaddoura T, Zemp R. TOBE-Costas Arrays for Fast High-Resolution 3-D Power Doppler Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:648-658. [PMID: 38743556 DOI: 10.1109/tuffc.2024.3400229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
Two-dimensional sparse arrays and row-column arrays are both alternatives to 2-D fully addressed arrays with lower channel counts. Row-column arrays have recently demonstrated fast 3-D structural and flow imaging but commonly suffer from high grating lobes or require multiplexing to achieve better quality. Two-dimensional sparse arrays enable full-volume acquisitions for each transmit event, but plane-wave transmissions with them usually lack quality in terms of uniformity of wavefronts. Here, we propose a novel architecture that combines both types of these arrays in one aperture, enabling imaging using row-column or sparse arrays alone or a hybrid imaging scheme where the row-column array is used in transmission and a 2-D sparse array in reception. This hybrid imaging scheme can potentially solve the shortcomings of each of these approaches. The sparse array layout chosen is a Costas array, characterized by having only one element per row and column, facilitating its integration with row-column arrays. We simulate images acquired with TOBE-Costas arrays using the hybrid imaging scheme and compare them to row-column and sparse spiral arrays of equivalent aperture size (128λ × 128λ at 7.5 MHz) in ultrafast plane-wave imaging of point targets and 3-D power Doppler imaging of synthetic flow phantoms. Our simulation results show that TOBE-Costas arrays exhibit superior resolution and lower sidelobe levels compared with plane-wave compounding with row-column arrays. Compared with density-tapered spiral arrays, they provide a larger field of view and finer resolution.
Collapse
|
2
|
Carlier B, Heymans SV, Nooijens S, Collado-Lara G, Toumia Y, Delombaerde L, Paradossi G, D’hooge J, Van Den Abeele K, Sterpin E, Himmelreich U. A Preliminary Investigation of Radiation-Sensitive Ultrasound Contrast Agents for Photon Dosimetry. Pharmaceuticals (Basel) 2024; 17:629. [PMID: 38794199 PMCID: PMC11125270 DOI: 10.3390/ph17050629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Revised: 04/28/2024] [Accepted: 04/30/2024] [Indexed: 05/26/2024] Open
Abstract
Radiotherapy treatment plans have become highly conformal, posing additional constraints on the accuracy of treatment delivery. Here, we explore the use of radiation-sensitive ultrasound contrast agents (superheated phase-change nanodroplets) as dosimetric radiation sensors. In a series of experiments, we irradiated perfluorobutane nanodroplets dispersed in gel phantoms at various temperatures and assessed the radiation-induced nanodroplet vaporization events using offline or online ultrasound imaging. At 25 °C and 37 °C, the nanodroplet response was only present at higher photon energies (≥10 MV) and limited to <2 vaporization events per cm2 per Gy. A strong response (~2000 vaporizations per cm2 per Gy) was observed at 65 °C, suggesting radiation-induced nucleation of the droplet core at a sufficiently high degree of superheat. These results emphasize the need for alternative nanodroplet formulations, with a more volatile perfluorocarbon core, to enable in vivo photon dosimetry. The current nanodroplet formulation carries potential as an innovative gel dosimeter if an appropriate gel matrix can be found to ensure reproducibility. Eventually, the proposed technology might unlock unprecedented temporal and spatial resolution in image-based dosimetry, thanks to the combination of high-frame-rate ultrasound imaging and the detection of individual vaporization events, thereby addressing some of the burning challenges of new radiotherapy innovations.
Collapse
Affiliation(s)
- Bram Carlier
- Department of Oncology, KU Leuven-University of Leuven, 3000 Leuven, Belgium; (B.C.); (L.D.); (E.S.)
- Department of Imaging and Pathology, KU Leuven-University of Leuven, 3000 Leuven, Belgium
- Molecular Small Animal Imaging Center (MoSAIC), KU Leuven-University of Leuven, 3000 Leuven, Belgium
| | - Sophie V. Heymans
- Department of Physics, KU Leuven Campus Kortrijk—KULAK, Etienne Sabbelaan 53, 8500 Kortrijk, Belgium; (S.V.H.); (K.V.D.A.)
- Department of Cardiovascular Sciences, KU Leuven-University of Leuven, 3000 Leuven, Belgium; (S.N.); (J.D.)
| | - Sjoerd Nooijens
- Department of Cardiovascular Sciences, KU Leuven-University of Leuven, 3000 Leuven, Belgium; (S.N.); (J.D.)
| | - Gonzalo Collado-Lara
- Department of Cardiology, Erasmus MC University Medical Center, 3015 GD Rotterdam, The Netherlands;
| | - Yosra Toumia
- National Institute for Nuclear Physics, INFN Sezione di Roma Tor Vergata, 00133 Rome, Italy;
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, 00133 Rome, Italy;
| | - Laurence Delombaerde
- Department of Oncology, KU Leuven-University of Leuven, 3000 Leuven, Belgium; (B.C.); (L.D.); (E.S.)
- Department of Radiotherapy, UH Leuven, 3000 Leuven, Belgium
| | - Gaio Paradossi
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, 00133 Rome, Italy;
| | - Jan D’hooge
- Department of Cardiovascular Sciences, KU Leuven-University of Leuven, 3000 Leuven, Belgium; (S.N.); (J.D.)
| | - Koen Van Den Abeele
- Department of Physics, KU Leuven Campus Kortrijk—KULAK, Etienne Sabbelaan 53, 8500 Kortrijk, Belgium; (S.V.H.); (K.V.D.A.)
| | - Edmond Sterpin
- Department of Oncology, KU Leuven-University of Leuven, 3000 Leuven, Belgium; (B.C.); (L.D.); (E.S.)
- Particle Therapy Interuniversity Center Leuven—PARTICLE, 3000 Leuven, Belgium
| | - Uwe Himmelreich
- Department of Imaging and Pathology, KU Leuven-University of Leuven, 3000 Leuven, Belgium
- Molecular Small Animal Imaging Center (MoSAIC), KU Leuven-University of Leuven, 3000 Leuven, Belgium
| |
Collapse
|
3
|
Jansen LC, Fekkes S, Schwab HM, Lopata RGP. Increasing abdominal aortic aneurysm curvature visibility using 3D dual probe bistatic ultrasound imaging combined with probe translation. ULTRASONICS 2024; 139:107284. [PMID: 38458061 DOI: 10.1016/j.ultras.2024.107284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 02/27/2024] [Accepted: 02/29/2024] [Indexed: 03/10/2024]
Abstract
High frame rate ultrasound (US) imaging techniques in 3D are promising tools for capturing abdominal aortic aneurysms (AAAs) over time, however, with the limited number of channel-to-element connections current footprints are small, which limits the field of view. Moreover, the maximal steering angle of the ultrasound beams in transmit and the maximal receptance angle in receive are insufficient for capturing the curvy shape of the AAA. Therefore, an approach is needed towards large arrays. In this study, high frame rate bistatic 3D US data (17 Hz) were acquired with two synchronized matrix arrays positioned at different locations (multi-aperture imaging) using a translation stage to simulate what a larger array with limited channel-to-element connections can potentially achieve. Acquisitions were performed along an AAA shaped phantom with different probe tilting angles (0 up to ± 30°). The performance of different multi-aperture configurations was quantified using the generalized contrast-to-noise ratio of the wall and lumen (gCNR). Furthermore, a parametric model of the multi-aperture system was used to estimate in which AAA wall regions the contrast is expected to be high. This was evaluated for AAAs with increasing diameters and curvature. With an eight-aperture 0° probe angle configuration a 69 % increase in field of view was measured in the longitudinal direction compared to the field of view of a single aperture configuration. When increasing the number of apertures from two to eight, the gCNR improved for the upper wall and lower wall by 35 % and 13 % (monostatic) and by 36 % and 13 % (bistatic). Contrast improvements up to 22 % (upper wall) and 12 % (lower wall) are achieved with tilted probe configurations compared to non-tilted configurations. Moreover, with bistatic imaging with tilted probe configurations gCNR improvements up to 4 % (upper wall) and 7 % (lower wall) are achieved compared to monostatic imaging. Furthermore, imaging with a larger inter-probe distance improved the gCNR for a ± 15° probe angle configuration. The gCNR has an expected pattern over time, where the contrast is lower when there is more wall motion (systole) and higher when motion is reduced (diastole). Furthermore, a higher frame rate (45 Hz) yields a lower gCNR, because fewer compound angles are used. The results of the parametric model suggest that a flat array is suitable for imaging AAA shapes with limited curvature, but that it is not suitable for imaging larger AAA shapes with more curvature. According to the model, tilted multi-aperture configurations combined with bistatic imaging can achieve a larger region with high contrast compared to non-tilted configurations. The findings of the model are in agreement with experimental findings. To conclude, this study demonstrates the vast improvements in field of view and AAA wall visibility that a large, sparsely populated 3D array can potentially achieve when imaging AAAs compared to single or dual aperture imaging. In the future, larger arrays, less thermal noise, more steering, and more channel-to-element connections combined with carefully chosen orientations of (sub-) apertures will likely advance 3D imaging of AAAs.
Collapse
Affiliation(s)
- Larissa C Jansen
- Photoacoustics and Ultrasound Laboratory Eindhoven, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands.
| | - Stein Fekkes
- Medical Ultrasound Imaging Center (MUSIC), Radboud University Medical Center, Nijmegen, the Netherlands
| | - Hans-Martin Schwab
- Photoacoustics and Ultrasound Laboratory Eindhoven, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Richard G P Lopata
- Photoacoustics and Ultrasound Laboratory Eindhoven, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
| |
Collapse
|
4
|
Dos Santos DS, Ossenkoppele B, Hopf YM, Soozande M, Noothout E, Vos HJ, Bosch JG, Pertijs MAP, Verweij MD, de Jong N. An Ultrasound Matrix Transducer for High-Frame-Rate 3-D Intra-cardiac Echocardiography. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:285-294. [PMID: 38036310 DOI: 10.1016/j.ultrasmedbio.2023.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 10/31/2023] [Accepted: 11/01/2023] [Indexed: 12/02/2023]
Abstract
OBJECTIVE Described here is the development of an ultrasound matrix transducer prototype for high-frame-rate 3-D intra-cardiac echocardiography. METHODS The matrix array consists of 16 × 18 lead zirconate titanate elements with a pitch of 160 µm × 160 µm built on top of an application-specific integrated circuit that generates transmission signals and digitizes the received signals. To reduce the number of cables in the catheter to a feasible number, we implement subarray beamforming and digitization in receive and use a combination of time-division multiplexing and pulse amplitude modulation data transmission, achieving an 18-fold reduction. The proposed imaging scheme employs seven fan-shaped diverging transmit beams operating at a pulse repetition frequency of 7.7 kHz to obtain a high frame rate. The performance of the prototype is characterized, and its functionality is fully verified. RESULTS The transducer exhibits a transmit efficiency of 28 Pa/V at 5 cm per element and a bandwidth of 60% in transmission. In receive, a dynamic range of 80 dB is measured with a minimum detectable pressure of 10 Pa per element. The element yield of the prototype is 98%, indicating the efficacy of the manufacturing process. The transducer is capable of imaging at a frame rate of up to 1000 volumes/s and is intended to cover a volume of 70° × 70° × 10 cm. CONCLUSION These advanced imaging capabilities have the potential to support complex interventional procedures and enable full-volumetric flow, tissue, and electromechanical wave tracking in the heart.
Collapse
Affiliation(s)
- Djalma Simões Dos Santos
- Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands.
| | - Boudewine Ossenkoppele
- Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Yannick M Hopf
- Electronic Instrumentation Laboratory, Delft University of Technology, Delft, The Netherlands
| | - Mehdi Soozande
- Department of Biomedical Engineering, Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Emile Noothout
- Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Hendrik J Vos
- Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands; Department of Biomedical Engineering, Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Johan G Bosch
- Department of Biomedical Engineering, Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Michiel A P Pertijs
- Electronic Instrumentation Laboratory, Delft University of Technology, Delft, The Netherlands
| | - Martin D Verweij
- Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands; Department of Biomedical Engineering, Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Nico de Jong
- Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands; Department of Biomedical Engineering, Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
5
|
Brown MD, Generowicz BS, Dijkhuizen S, Koekkoek SKE, Strydis C, Bosch JG, Arvanitis P, Springeling G, Leus GJT, De Zeeuw CI, Kruizinga P. Four-dimensional computational ultrasound imaging of brain hemodynamics. SCIENCE ADVANCES 2024; 10:eadk7957. [PMID: 38232164 DOI: 10.1126/sciadv.adk7957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Accepted: 12/19/2023] [Indexed: 01/19/2024]
Abstract
Four-dimensional ultrasound imaging of complex biological systems such as the brain is technically challenging because of the spatiotemporal sampling requirements. We present computational ultrasound imaging (cUSi), an imaging method that uses complex ultrasound fields that can be generated with simple hardware and a physical wave prediction model to alleviate the sampling constraints. cUSi allows for high-resolution four-dimensional imaging of brain hemodynamics in awake and anesthetized mice.
Collapse
Affiliation(s)
- Michael D Brown
- Department of Neuroscience, CUBE, Erasmus MC, Rotterdam, Netherlands
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | | | | | | | - Christos Strydis
- Department of Neuroscience, CUBE, Erasmus MC, Rotterdam, Netherlands
- Department of Quantum and Computer Engineering, TU Delft, Delft, Netherlands
| | - Johannes G Bosch
- Department of Cardiology, Thorax Biomedical Engineering, Erasmus MC, Rotterdam, Netherlands
| | - Petros Arvanitis
- Department of Neuroscience, CUBE, Erasmus MC, Rotterdam, Netherlands
| | - Geert Springeling
- Experimental Medical Instrumentation, Erasmus MC, Rotterdam, Netherlands
| | - Geert J T Leus
- Signal Processing Systems, Department of Microelectronics, TU Delft, Delft, Netherlands
| | - Chris I De Zeeuw
- Department of Neuroscience, Erasmus MC, Rotterdam, Netherlands
- Netherlands Institute for Neuroscience, Royal Dutch Academy for Arts and Sciences, Amsterdam, Netherlands
| | - Pieter Kruizinga
- Department of Neuroscience, CUBE, Erasmus MC, Rotterdam, Netherlands
- Signal Processing Systems, Department of Microelectronics, TU Delft, Delft, Netherlands
| |
Collapse
|
6
|
Wei L, Wahyulaksana G, Te Lintel Hekkert M, Beurskens R, Boni E, Ramalli A, Noothout E, Duncker DJ, Tortoli P, van der Steen AFW, de Jong N, Verweij M, Vos HJ. High-Frame-Rate Volumetric Porcine Renal Vasculature Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:2476-2482. [PMID: 37704558 DOI: 10.1016/j.ultrasmedbio.2023.08.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 07/02/2023] [Accepted: 08/08/2023] [Indexed: 09/15/2023]
Abstract
OBJECTIVE The aim of this study was to assess the feasibility and imaging options of contrast-enhanced volumetric ultrasound kidney vasculature imaging in a porcine model using a prototype sparse spiral array. METHODS Transcutaneous freehand in vivo imaging of two healthy porcine kidneys was performed according to three protocols with different microbubble concentrations and transmission sequences. Combining high-frame-rate transmission sequences with our previously described spatial coherence beamformer, we determined the ability to produce detailed volumetric images of the vasculature. We also determined power, color and spectral Doppler, as well as super-resolved microvasculature in a volume. The results were compared against a clinical 2-D ultrasound machine. RESULTS Three-dimensional visualization of the kidney vasculature structure and blood flow was possible with our method. Good structural agreement was found between the visualized vasculature structure and the 2-D reference. Microvasculature patterns in the kidney cortex were visible with super-resolution processing. Blood flow velocity estimations were within a physiological range and pattern, also in agreement with the 2-D reference results. CONCLUSION Volumetric imaging of the kidney vasculature was possible using a prototype sparse spiral array. Reliable structural and temporal information could be extracted from these imaging results.
Collapse
Affiliation(s)
- Luxi Wei
- Department of Cardiology, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
| | - Geraldi Wahyulaksana
- Department of Cardiology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | | | - Robert Beurskens
- Department of Cardiology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Enrico Boni
- Department of Information Engineering, University of Florence, Florence, Italy
| | - Alessandro Ramalli
- Department of Information Engineering, University of Florence, Florence, Italy
| | - Emile Noothout
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Dirk J Duncker
- Department of Cardiology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Piero Tortoli
- Department of Information Engineering, University of Florence, Florence, Italy
| | - Antonius F W van der Steen
- Department of Cardiology, Erasmus MC University Medical Center, Rotterdam, The Netherlands; Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Nico de Jong
- Department of Cardiology, Erasmus MC University Medical Center, Rotterdam, The Netherlands; Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Martin Verweij
- Department of Cardiology, Erasmus MC University Medical Center, Rotterdam, The Netherlands; Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Hendrik J Vos
- Department of Cardiology, Erasmus MC University Medical Center, Rotterdam, The Netherlands; Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| |
Collapse
|
7
|
Chen Y, Zhuang Z, Luo J, Luo X. Doppler and Pair-Wise Optical Flow Constrained 3D Motion Compensation for 3D Ultrasound Imaging. IEEE TRANSACTIONS ON IMAGE PROCESSING : A PUBLICATION OF THE IEEE SIGNAL PROCESSING SOCIETY 2023; 32:4501-4516. [PMID: 37540607 DOI: 10.1109/tip.2023.3300591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/06/2023]
Abstract
Volumetric (3D) ultrasound imaging using a 2D matrix array probe is increasingly developed for various clinical procedures. However, 3D ultrasound imaging suffers from motion artifacts due to tissue motions and a relatively low frame rate. Current Doppler-based motion compensation (MoCo) methods only allow 1D compensation in the in-range dimension. In this work, we propose a new 3D-MoCo framework that combines 3D velocity field estimation and a two-step compensation strategy for 3D diverging wave compounding imaging. Specifically, our framework explores two constraints of a round-trip scan sequence of 3D diverging waves, i.e., Doppler and pair-wise optical flow, to formulate the estimation of the 3D velocity fields as a global optimization problem, which is further regularized by the divergence-free and first-order smoothness. The two-step compensation strategy is to first compensate for the 1D displacements in the in-range dimension and then the 2D displacements in the two mutually orthogonal cross-range dimensions. Systematical in-silico experiments were conducted to validate the effectiveness of our proposed 3D-MoCo method. The results demonstrate that our 3D-MoCo method achieves higher image contrast, higher structural similarity, and better speckle patterns than the corresponding 1D-MoCo method. Particularly, the 2D cross-range compensation is effective for fully recovering image quality.
Collapse
|
8
|
Masoumi MH, Kaddoura T, Zemp RJ. Costas Sparse 2-D Arrays for High-Resolution Ultrasound Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2023; 70:460-472. [PMID: 37028300 DOI: 10.1109/tuffc.2023.3256339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Two-dimensional arrays enable volumetric ultrasound imaging but have been limited to small aperture size and hence low resolution due to the high cost and complexity of fabrication, addressing, and processing associated with large fully addressed arrays. Here, we propose Costas arrays as a gridded sparse 2-D array architecture for volumetric ultrasound imaging. Costas arrays have exactly one element for every row and column, such that the vector displacement between any pair of elements is unique. These properties ensure aperiodicity, which helps eliminate grating lobes. Compared with previously reported works, we studied the distribution of active elements based on an order-256 Costas layout on a wider aperture ( 96 λ×96 λ at 7.5 MHz center frequency) for high-resolution imaging. Our investigations with focused scanline imaging of point targets and cyst phantoms showed that Costas arrays exhibit lower peak sidelobe levels compared with random sparse arrays of the same size and offer comparable performance in terms of contrast compared with Fermat spiral arrays. In addition, Costas arrays are gridded, which could ease the manufacturing and has one element for each row/column, which enables simple interconnection strategies. Compared with state-of-the-art matrix probes, which are commonly 32×32 , the proposed sparse arrays achieve higher lateral resolution and a wider field of view.
Collapse
|
9
|
Favre H, Pernot M, Tanter M, Papadacci C. Transcranial 3D ultrasound localization microscopy using a large element matrix array with a multi-lens diffracting layer: an in vitrostudy. Phys Med Biol 2023; 68. [PMID: 36808924 DOI: 10.1088/1361-6560/acbde3] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Accepted: 02/21/2023] [Indexed: 02/23/2023]
Abstract
Objective. Early diagnosis and acute knowledge of cerebral disease require to map the microflows of the whole brain. Recently, ultrasound localization microscopy (ULM) was applied to map and quantify blood microflows in 2D in the brain of adult patients down to the micron scale. Whole brain 3D clinical ULM remains challenging due to the transcranial energy loss which reduces significantly the imaging sensitivity.Approach. Large aperture probes with a large surface can increase both the field of view and sensitivity. However, a large active surface implies thousands of acoustic elements, which limits clinical translation. In a previous simulation study, we developed a new probe concept combining a limited number of elements and a large aperture. It is based on large elements, to increase sensitivity, and a multi-lens diffracting layer to improve the focusing quality. In this study, a 16 elements prototype, driven at 1 MHz frequency, was made andin vitroexperiments were performed to validate the imaging capabilities of this new probe concept.Main results. First, pressure fields emitted from a large single transducer element without and with diverging lens were compared. Low directivity was measured for the large element with the diverging lens while maintaining high transmit pressure. The focusing quality of 4 × 3cm matrix arrays of 16 elements without/with lenses were compared.In vitroexperiments in a water tank and through a human skull were achieved to localize and track microbubbles in tubes.Significance.ULM was achieved demonstrating the strong potential of multi-lens diffracting layer to enable microcirculation assessment over a large field of view through the bones.
Collapse
Affiliation(s)
- Hugues Favre
- Institute Physics for Medicine Paris, Inserm U1273, ESPCI Paris-PSL, Cnrs UMR8063, 75012 Paris, France
| | - Mathieu Pernot
- Institute Physics for Medicine Paris, Inserm U1273, ESPCI Paris-PSL, Cnrs UMR8063, 75012 Paris, France
| | - Mickael Tanter
- Institute Physics for Medicine Paris, Inserm U1273, ESPCI Paris-PSL, Cnrs UMR8063, 75012 Paris, France
| | - Clément Papadacci
- Institute Physics for Medicine Paris, Inserm U1273, ESPCI Paris-PSL, Cnrs UMR8063, 75012 Paris, France
| |
Collapse
|
10
|
Godefroy G, Arnal B, Bossy E. Full-visibility 3D imaging of oxygenation and blood flow by simultaneous multispectral photoacoustic fluctuation imaging (MS-PAFI) and ultrasound Doppler. Sci Rep 2023; 13:2961. [PMID: 36806304 PMCID: PMC9941110 DOI: 10.1038/s41598-023-29177-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 01/31/2023] [Indexed: 02/22/2023] Open
Abstract
We present a method and setup that provide complementary three-dimensional (3D) images of blood oxygenation (via quantitative photoacoustic imaging) and blood flow dynamics (via ultrasound Doppler). The proposed approach is label-free and exploits blood-induced fluctuations, and is implemented on a sparse array with only 256 elements, driven with a commercially available ultrasound electronics. We first implement 3D photoacoustic fluctuation imaging (PAFI) to image chicken embryo, and obtain full-visibility images of the vascular morphology. We obtain simultaneously 3D ultrasound power Doppler with a comparable image quality. We then introduce multispectral photoacoustic fluctuation imaging (MS-PAFI), and demonstrate that it can provide quantitative measurements of the absorbed optical energy density with full visibility and enhanced contrast, as compared to conventional delay-and-sum multispectral photoacoustic imaging. We finally showcase the synergy and complementarity between MS-PAFI, which provides 3D quantitative oxygenation (SO[Formula: see text]) imaging, and 3D ultrasound Doppler, which provides quantitative information on blood flow dynamics. MS-PAFI represents a promising alternative to model-based inversions with the advantage of resolving all the visibility artefacts without prior and regularization, by use of a straightforward processing scheme.
Collapse
Affiliation(s)
- Guillaume Godefroy
- grid.462689.70000 0000 9272 9931Univ. Grenoble Alpes, LIPhy, CNRS, Grenoble, 38000 France
| | - Bastien Arnal
- grid.462689.70000 0000 9272 9931Univ. Grenoble Alpes, LIPhy, CNRS, Grenoble, 38000 France
| | - Emmanuel Bossy
- Univ. Grenoble Alpes, LIPhy, CNRS, Grenoble, 38000, France.
| |
Collapse
|
11
|
dos Santos DS, Fool F, Mozaffarzadeh M, Shabanimotlagh M, Noothout E, Kim T, Rozsa N, Vos HJ, Bosch JG, Pertijs MAP, Verweij MD, de Jong N. A Tiled Ultrasound Matrix Transducer for Volumetric Imaging of the Carotid Artery. SENSORS (BASEL, SWITZERLAND) 2022; 22:9799. [PMID: 36560168 PMCID: PMC9784751 DOI: 10.3390/s22249799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 12/09/2022] [Accepted: 12/12/2022] [Indexed: 06/17/2023]
Abstract
High frame rate three-dimensional (3D) ultrasound imaging would offer excellent possibilities for the accurate assessment of carotid artery diseases. This calls for a matrix transducer with a large aperture and a vast number of elements. Such a matrix transducer should be interfaced with an application-specific integrated circuit (ASIC) for channel reduction. However, the fabrication of such a transducer integrated with one very large ASIC is very challenging and expensive. In this study, we develop a prototype matrix transducer mounted on top of multiple identical ASICs in a tiled configuration. The matrix was designed to have 7680 piezoelectric elements with a pitch of 300 μm × 150 μm integrated with an array of 8 × 1 tiled ASICs. The performance of the prototype is characterized by a series of measurements. The transducer exhibits a uniform behavior with the majority of the elements working within the -6 dB sensitivity range. In transmit, the individual elements show a center frequency of 7.5 MHz, a -6 dB bandwidth of 45%, and a transmit efficiency of 30 Pa/V at 200 mm. In receive, the dynamic range is 81 dB, and the minimum detectable pressure is 60 Pa per element. To demonstrate the imaging capabilities, we acquired 3D images using a commercial wire phantom.
Collapse
Affiliation(s)
- Djalma Simões dos Santos
- Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands
| | - Fabian Fool
- Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands
| | - Moein Mozaffarzadeh
- Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands
| | - Maysam Shabanimotlagh
- Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands
| | - Emile Noothout
- Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands
| | - Taehoon Kim
- Electronic Instrumentation Laboratory, Delft University of Technology, 2628 CD Delft, The Netherlands
| | - Nuriel Rozsa
- Electronic Instrumentation Laboratory, Delft University of Technology, 2628 CD Delft, The Netherlands
| | - Hendrik J. Vos
- Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands
- Department Biomedical Engineering, Thoraxcenter, Erasmus Medical Center, 3015 GD Rotterdam, The Netherlands
| | - Johan G. Bosch
- Department Biomedical Engineering, Thoraxcenter, Erasmus Medical Center, 3015 GD Rotterdam, The Netherlands
| | - Michiel A. P. Pertijs
- Electronic Instrumentation Laboratory, Delft University of Technology, 2628 CD Delft, The Netherlands
| | - Martin D. Verweij
- Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands
- Department Biomedical Engineering, Thoraxcenter, Erasmus Medical Center, 3015 GD Rotterdam, The Netherlands
| | - Nico de Jong
- Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands
- Department Biomedical Engineering, Thoraxcenter, Erasmus Medical Center, 3015 GD Rotterdam, The Netherlands
| |
Collapse
|
12
|
Ramalli A, Boni E, Roux E, Liebgott H, Tortoli P. Design, Implementation, and Medical Applications of 2-D Ultrasound Sparse Arrays. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:2739-2755. [PMID: 35333714 DOI: 10.1109/tuffc.2022.3162419] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
An ultrasound sparse array consists of a sparse distribution of elements over a 2-D aperture. Such an array is typically characterized by a limited number of elements, which in most cases is compatible with the channel number of the available scanners. Sparse arrays represent an attractive alternative to full 2-D arrays that may require the control of thousands of elements through expensive application-specific integrated circuits (ASICs). However, their massive use is hindered by two main drawbacks: the possible beam profile deterioration, which may worsen the image contrast, and the limited signal-to-noise ratio (SNR), which may result too low for some applications. This article reviews the work done for three decades on 2-D ultrasound sparse arrays for medical applications. First, random, optimized, and deterministic design methods are reviewed together with their main influencing factors. Then, experimental 2-D sparse array implementations based on piezoelectric and capacitive micromachined ultrasonic transducer (CMUT) technologies are presented. Sample applications to 3-D (Doppler) imaging, super-resolution imaging, photo-acoustic imaging, and therapy are reported. The final sections discuss the main shortcomings associated with the use of sparse arrays, the related countermeasures, and the next steps envisaged in the development of innovative arrays.
Collapse
|
13
|
Wei L, Boni E, Ramalli A, Fool F, Noothout E, van der Steen AFW, Verweij MD, Tortoli P, De Jong N, Vos HJ. Sparse 2-D PZT-on-PCB Arrays With Density Tapering. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:2798-2809. [PMID: 36067108 DOI: 10.1109/tuffc.2022.3204118] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Two-dimensional (2-D) arrays offer volumetric imaging capabilities without the need for probe translation or rotation. A sparse array with elements seeded in a tapering spiral pattern enables one-to-one connection to an ultrasound machine, thus allowing flexible transmission and reception strategies. To test the concept of sparse spiral array imaging, we have designed, realized, and characterized two prototype probes designed at 2.5-MHz low-frequency (LF) and 5-MHz high-frequency (HF) center frequencies. Both probes share the same electronic design, based on piezoelectric ceramics and rapid prototyping with printed circuit board substrates to wire the elements to external connectors. Different center frequencies were achieved by adjusting the piezoelectric layer thickness. The LF and HF prototype probes had 88% and 95% of working elements, producing peak pressures of 21 and 96 kPa/V when focused at 5 and 3 cm, respectively. The one-way -3-dB bandwidths were 26% and 32%. These results, together with experimental tests on tissue-mimicking phantoms, show that the probes are viable for volumetric imaging.
Collapse
|
14
|
Requirements and Hardware Limitations of High-Frame-Rate 3-D Ultrasound Imaging Systems. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12136562] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
Abstract
The spread of high frame rate and 3-D imaging techniques has raised pressing requirements for ultrasound systems. In particular, the processing power and data transfer rate requirements may be so demanding to hinder the real-time (RT) implementation of such techniques. This paper first analyzes the general requirements involved in RT ultrasound systems. Then, it identifies the main bottlenecks in the receiving section of a specific RT scanner, the ULA-OP 256, which is one of the most powerful available open scanners and may therefore be assumed as a reference. This case study has evidenced that the “star” topology, used to digitally interconnect the system’s boards, may easily saturate the data transfer bandwidth, thus impacting the achievable frame/volume rates in RT. The architecture of the digital scanner was exploited to tackle the bottlenecks by enabling a new “ring“ communication topology. Experimental 2-D and 3-D high-frame-rate imaging tests were conducted to evaluate the frame rates achievable with both interconnection modalities. It is shown that the ring topology enables up to 4400 frames/s and 510 volumes/s, with mean increments of +230% (up to +620%) compared to the star topology.
Collapse
|
15
|
Favre H, Pernot M, Tanter M, Papadacci C. Boosting transducer matrix sensitivity for 3D large field ultrasound localization microscopy using a multi-lens diffracting layer: a simulation study. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac5f72] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Accepted: 03/21/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Mapping blood microflows of the whole brain is crucial for early diagnosis of cerebral diseases. Ultrasound localization microscopy (ULM) was recently applied to map and quantify blood microflows in 2D in the brain of adult patients down to the micron scale. Whole brain 3D clinical ULM remains challenging due to the transcranial energy loss which significantly reduces the imaging sensitivity. Large aperture probes with a large surface can increase both resolution and sensitivity. However, a large active surface implies thousands of acoustic elements, with limited clinical translation. In this study, we investigate via simulations a new high-sensitive 3D imaging approach based on large diverging elements, combined with an adapted beamforming with corrected delay laws, to increase sensitivity. First, pressure fields from single elements with different sizes and shapes were simulated. High directivity was measured for curved element while maintaining high transmit pressure. Matrix arrays of 256 elements with a dimension of 10 × 10 cm with small (λ/2), large (4λ), and curved elements (4λ) were compared through point spread functions analysis. A large synthetic microvessel phantom filled with 100 microbubbles per frame was imaged using the matrix arrays in a transcranial configuration. 93% of the bubbles were detected with the proposed approach demonstrating that the multi-lens diffracting layer has a strong potential to enable 3D ULM over a large field of view through the bones.
Collapse
|