1
|
Smith BL, Hankinson T, Maher S. Portable Instrumentation for Ambient Ionization and Miniature Mass Spectrometers. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2024; 17:69-102. [PMID: 38640067 DOI: 10.1146/annurev-anchem-061522-040824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/21/2024]
Abstract
We critically evaluate the current status of portable mass spectrometry (pMS), particularly where this aligns with ambient ionization. Assessing the field of pMS can be quite subjective, especially in relation to the portable aspects of design, deployment, and operation. In this review, we discuss what it means to be portable and introduce a set of criteria by which pMS and ambient ionization sources can be assessed. Moreover, we consider the recent literature in terms of the most popular and significant advances in portable instrumentation for ambient ionization and miniature mass spectrometers. Finally, emerging trends and exciting future prospects are discussed and some recommendations are offered.
Collapse
Affiliation(s)
- Barry L Smith
- Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, United Kingdom;
| | - Thomas Hankinson
- Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, United Kingdom;
| | - Simon Maher
- Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, United Kingdom;
| |
Collapse
|
2
|
Calero-Cañuelo C, Casado-Carmona FA, Lucena R, Cárdenas S. Sorptive tape-spray tandem mass spectrometry using aluminum foil coated with mixed-mode microparticles. Talanta 2024; 272:125774. [PMID: 38359721 DOI: 10.1016/j.talanta.2024.125774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 02/06/2024] [Accepted: 02/07/2024] [Indexed: 02/17/2024]
Abstract
Direct mass spectrometry (MS) is an exciting strategy in bioanalysis, enabling rapid decision-making in different scenarios. Its application is usually hindered by matrix effects and the typically low concentration of the target compounds in the biofluids. In this sense, combining a previous sample preparation step minimizes or removes these shortcomings. This article describes sorptive tape-spray tandem mass spectrometry (STS-MS/MS) based on mixed-mode particles as a strategy to combine sample preparation and MS analysis in a single device. The technique uses a sorptive tape (ST) consisting of mixed-mode polymeric microparticles (combining ionic exchange and hydrophobic interactions) coated over aluminum foil in a spatial controlled way. The tapes act as the sorptive phases to isolate the analytes from the sample matrix and substrates for STS-MS/MS. The performance of the technique has been evaluated by developing a method to determine codeine in saliva as proof of concept. The affordability of the STs elements allows the preparation of many individual phases at low cost so that several samples can be extracted simultaneously, thus increasing the sample throughput. The extraction variables were optimized following a multivariate approach. Working under the optimum conditions, the limit of detection was 0.3 μg L-1, while the intraday precision, calculated as relative standard deviation (RSD) at three concentration levels, was better than 9.4 %. The accuracy, expressed as relative recovery, was in the range of 78-98 %. The method was also applied to the analysis of real samples. Despite being a powerful strategy, the direct combination of microextraction to MS is not always affordable in all laboratories. For this reason, the STs were also combined with commercial liquid chromatography-MS working under the direct infusion mode to demonstrate the usefulness of the ST in classical extraction workflows.
Collapse
Affiliation(s)
- Carlos Calero-Cañuelo
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| | - Francisco Antonio Casado-Carmona
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain; FI-TRACE Group, Department of Chemistry, Faculty of Science, University of the Balearic Islands, Carretera de Valldemossa Km 7.5, E-07122, Palma de Mallorca, Illes Balears, Spain
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| |