Beyer C, Paul KM, Dorsch S, Echner G, Dinkel F, Welzel T, Seidensaal K, Hörner-Rieber J, Jäkel O, Debus J, Klüter S. Compliance of volunteers in a fully-enclosed patient rotation system for MR-guided radiation therapy: a prospective study. Radiat Oncol 2024; 19:71. [PMID: 38849900 PMCID: PMC11162055 DOI: 10.1186/s13014-024-02461-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Accepted: 05/24/2024] [Indexed: 06/09/2024] Open
Abstract
BACKGROUND Particle therapy makes a noteworthy contribution in the treatment of tumor diseases. In order to be able to irradiate from different angles, usually expensive, complex and large gantries are used. Instead rotating the beam via a gantry, the patient itself might be rotated. Here we present tolerance and compliance of volunteers for a fully-enclosed patient rotation system in a clinical magnetic resonance (MR)-scanner for potential use in MR-guided radiotherapy, conducted within a prospective evaluation study. METHODS A patient rotation system was used to simulate and perform magnetic resonance imaging (MRI)-examinations with 50 volunteers without an oncological question. For 20 participants, the MR-examination within the bore was simulated by introducing realistic MRI noise, whereas 30 participants received an examination with image acquisition. Initially, body parameters and claustrophobia were assessed. The subjects were then rotated to different angles for simulation (0°, 45°, 90°, 180°) and imaging (0°, 70°, 90°, 110°). At each angle, anxiety and motion sickness were assessed using a 6-item State-Trait-Anxiety-Inventory (STAI-6) and a modified Motion Sickness Assessment Questionnaire (MSAQ). In addition, general areas of discomfort were evaluated. RESULTS Out of 50 subjects, three (6%) subjects terminated the study prematurely. One subject dropped out during simulation due to nausea while rotating to 45°. During imaging, further two subjects dropped out due to shoulder pain from positioning at 90° and 110°, respectively. The average result for claustrophobia (0 = no claustrophobia to 4 = extreme claustrophobia) was none to light claustrophobia (average score: simulation 0.64 ± 0.33, imaging 0.51 ± 0.39). The mean anxiety scores (0% = no anxiety to 100% = maximal anxiety) were 11.04% (simulation) and 15.82% (imaging). Mean motion sickness scores (0% = no motion sickness to 100% = maximal motion sickness) of 3.5% (simulation) and 6.76% (imaging) were obtained across all participants. CONCLUSION Our study proves the feasibility of horizontal rotation in a fully-enclosed rotation system within an MR-scanner. Anxiety scores were low and motion sickness was only a minor influence. Both anxiety and motion sickness showed no angular dependency. Further optimizations with regard to immobilization in the rotation device may increase subject comfort.
Collapse
Affiliation(s)
- Cedric Beyer
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
- Heidelberg Institute of Radiation Oncology (HIRO) and National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany.
- National Center for Tumor Diseases (NCT), Heidelberg, Germany.
| | - Katharina Maria Paul
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO) and National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Stefan Dorsch
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO) and National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Gernot Echner
- Heidelberg Institute of Radiation Oncology (HIRO) and National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Fabian Dinkel
- Heidelberg Institute of Radiation Oncology (HIRO) and National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Thomas Welzel
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO) and National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Katharina Seidensaal
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO) and National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Juliane Hörner-Rieber
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO) and National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Oliver Jäkel
- Heidelberg Institute of Radiation Oncology (HIRO) and National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Department of Radiation Oncology, Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, Heidelberg, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO) and National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Department of Radiation Oncology, Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, Heidelberg, Germany
| | - Sebastian Klüter
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
- Heidelberg Institute of Radiation Oncology (HIRO) and National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany.
- National Center for Tumor Diseases (NCT), Heidelberg, Germany.
| |
Collapse
|
2
|
Chen X, Cao Y, Zhang K, Wang Z, Xie X, Wang Y, Men K, Dai J. Technical note: A method to synthesize magnetic resonance images in different patient rotation angles with deep learning for gantry-free radiotherapy. Med Phys 2023; 50:1746-1755. [PMID: 36135718 DOI: 10.1002/mp.15981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Revised: 08/29/2022] [Accepted: 08/31/2022] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND Recently, patient rotating devices for gantry-free radiotherapy, a new approach to implement external beam radiotherapy, have been introduced. When a patient is rotated in the horizontal position, gravity causes anatomic deformation. For treatment planning, one feasible method is to acquire simulation images at different horizontal rotation angles. PURPOSE This study aimed to investigate the feasibility of synthesizing magnetic resonance (MR) images at patient rotation angles of 180° (prone position) and 90° (lateral position) from those at a rotation angle of 0° (supine position) using deep learning. METHODS This study included 23 healthy male volunteers. They underwent MR imaging (MRI) in the supine position and then in the prone (23 volunteers) and lateral (16 volunteers) positions. T1-weighted fast spin echo was performed for all positions with the same parameters. Two two-dimensional deep learning networks, pix2pix generative adversarial network (pix2pix GAN) and CycleGAN, were developed for synthesizing MR images in the prone and lateral positions from those in the supine position, respectively. For the evaluation of the models, leave-one-out cross-validation was performed. The mean absolute error (MAE), Dice similarity coefficient (DSC), and Hausdorff distance (HD) were used to determine the agreement between the prediction and ground truth for the entire body and four specific organs. RESULTS For pix2pix GAN, the synthesized images were visually bad, and no quantitative evaluation was performed. The quantitative evaluation metrics of the body outlines calculated for the synthesized prone and lateral images using CycleGAN were as follows: MAE, 35.63 ± 3.98 and 40.45 ± 5.83, respectively; DSC, 0.97 ± 0.01 and 0.94 ± 0.01, respectively; and HD (in pixels), 16.74 ± 3.55 and 31.69 ± 12.03, respectively. The quantitative metrics of the bladder and prostate performed were also promising for both the prone and lateral images, with mean values >0.90 in DSC (p > 0.05). The mean DSC and HD values of the bilateral femur for the prone images were 0.96 and 3.63 (in pixels), respectively, and 0.78 and 12.65 (in pixels) for the lateral images, respectively (p < 0.05). CONCLUSIONS The CycleGAN could synthesize the MRI at lateral and prone positions using images at supine position, and it could benefit gantry-free radiation therapy.
Collapse
Affiliation(s)
- Xinyuan Chen
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- National Cancer Center/National Clinical Research Center for Cancer/Hebei Cancer Hospital, Chinese Academy of Medical Sciences, Langfang, China
| | - Ying Cao
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Kaixuan Zhang
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Zhen Wang
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Xuejie Xie
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yunxiang Wang
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Kuo Men
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jianrong Dai
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
3
|
Patterson E, Oborn BM, Cutajar D, Jelen U, Liney G, Rosenfeld AB, Metcalfe PE. Characterizing magnetically focused contamination electrons by off-axis irradiation on an inline MRI-Linac. J Appl Clin Med Phys 2022; 23:e13591. [PMID: 35333000 PMCID: PMC9195023 DOI: 10.1002/acm2.13591] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 12/10/2021] [Accepted: 03/02/2022] [Indexed: 11/18/2022] Open
Abstract
Purpose The aim of this study is to investigate off‐axis irradiation on the Australian MRI‐Linac using experiments and Monte Carlo simulations. Simulations are used to verify experimental measurements and to determine the minimum offset distance required to separate electron contamination from the photon field. Methods Dosimetric measurements were performed using a microDiamond detector, Gafchromic® EBT3 film, and MOSkinTM. Three field sizes were investigated including 1.9 × 1.9, 5.8 × 5.8, and 9.7 × 9.6 cm2. Each field was offset a maximum distance, approximately 10 cm, from the central magnetic axis (isocenter). Percentage depth doses (PDDs) were collected at a source‐to‐surface distance (SSD) of 1.8 m for fields collimated centrally and off‐axis. PDD measurements were also acquired at isocenter for each off‐axis field to measure electron contamination. Monte Carlo simulations were used to verify experimental measurements, determine the minimum field offset distance, and demonstrate the use of a spoiler to absorb electron contamination. Results Off‐axis irradiation separates the majority of electron contamination from an x‐ray beam and was found to significantly reduce in‐field surface dose. For the 1.9 × 1.9, 5.8 × 5.8, and 9.7 × 9.6 cm2 field, surface dose was reduced from 120.9% to 24.9%, 229.7% to 39.2%, and 355.3% to 47.3%, respectively. Monte Carlo simulations generally were within experimental error to MOSkinTM and microDiamond, and used to determine the minimum offset distance, 2.1 cm, from the field edge to isocenter. A water spoiler 2 cm thick was shown to reduce electron contamination dose to near zero. Conclusions Experimental and simulation data were acquired for a range of field sizes to investigate off‐axis irradiation on an inline MRI‐Linac. The skin sparing effect was observed with off‐axis irradiation, a feature that cannot be achieved to the same extent with other methods, such as bolusing, for beams at isocenter.
Collapse
Affiliation(s)
| | - Bradley M Oborn
- Centre for Medical Radiation Physics, Wollongong, NSW, Australia.,Illawarra Cancer Care Centre, Wollongong Hospital, Wollongong, NSW, Australia
| | - Dean Cutajar
- Centre for Medical Radiation Physics, Wollongong, NSW, Australia
| | - Urszula Jelen
- Ingham Institute for Applied Medical Research, Liverpool, NSW, Australia
| | - Gary Liney
- Ingham Institute for Applied Medical Research, Liverpool, NSW, Australia
| | - Anatoly B Rosenfeld
- Centre for Medical Radiation Physics, Wollongong, NSW, Australia.,Illawarra Health Medical Research Institute, University of Wollongong, Wollongong, NSW, Australia
| | - Peter E Metcalfe
- Centre for Medical Radiation Physics, Wollongong, NSW, Australia.,Ingham Institute for Applied Medical Research, Liverpool, NSW, Australia
| |
Collapse
|
4
|
Hegarty S, Hardcastle N, Korte J, Kron T, Everitt S, Rahim S, Hegi-Johnson F, Franich R. Please Place Your Seat in the Full Upright Position: A Technical Framework for Landing Upright Radiation Therapy in the 21 st Century. Front Oncol 2022; 12:821887. [PMID: 35311128 PMCID: PMC8929673 DOI: 10.3389/fonc.2022.821887] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Accepted: 01/27/2022] [Indexed: 12/20/2022] Open
Abstract
Delivering radiotherapy to patients in an upright position can allow for increased patient comfort, reduction in normal tissue irradiation, or reduction of machine size and complexity. This paper gives an overview of the requirements for the delivery of contemporary arc and modulated radiation therapy to upright patients. We explore i) patient positioning and immobilization, ii) simulation imaging, iii) treatment planning and iv) online setup and image guidance. Treatment chairs have been designed to reproducibly position seated patients for treatment and can be augmented by several existing immobilisation systems or promising emerging technologies such as soft robotics. There are few solutions for acquiring CT images for upright patients, however, cone beam computed tomography (CBCT) scans of upright patients can be produced using the imaging capabilities of standard Linacs combined with an additional patient rotation device. While these images will require corrections to make them appropriate for treatment planning, several methods indicate the viability of this approach. Treatment planning is largely unchanged apart from translating gantry rotation to patient rotation, allowing for a fixed beam with a patient rotating relative to it. Rotation can be provided by a turntable during treatment delivery. Imaging the patient with the same machinery as used in treatment could be advantageous for online plan adaption. While the current focus is using clinical linacs in existing facilities, developments in this area could also extend to lower-cost and mobile linacs and heavy ion therapy.
Collapse
Affiliation(s)
- Sarah Hegarty
- School of Science, RMIT University, Melbourne, VIC, Australia.,Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Nicholas Hardcastle
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia.,Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia.,Sir Peter MacCallum Department of Oncology, Faculty of Medicine, Dentistry and Health Science, University of Melbourne, Parkville, VIC, Australia
| | - James Korte
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia.,Department of Biomedical Engineering, School of Engineering, University of Melbourne, Melbourne, VIC, Australia
| | - Tomas Kron
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia.,Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia.,Sir Peter MacCallum Department of Oncology, Faculty of Medicine, Dentistry and Health Science, University of Melbourne, Parkville, VIC, Australia
| | - Sarah Everitt
- Sir Peter MacCallum Department of Oncology, Faculty of Medicine, Dentistry and Health Science, University of Melbourne, Parkville, VIC, Australia.,Department of Radiation Therapy, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Sulman Rahim
- Department of Radiation Therapy, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Fiona Hegi-Johnson
- Sir Peter MacCallum Department of Oncology, Faculty of Medicine, Dentistry and Health Science, University of Melbourne, Parkville, VIC, Australia.,Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Rick Franich
- School of Science, RMIT University, Melbourne, VIC, Australia.,Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| |
Collapse
|
5
|
Gardner M, Dillon O, Shieh CC, O'Brien R, Debrot E, Barber J, Ahern V, Bennett P, Heng SM, Corde S, Jackson M, Keall P. The adaptation and investigation of cone-beam CT reconstruction algorithms for horizontal rotation fixed-gantry scans of rabbits. Phys Med Biol 2021; 66. [PMID: 33878747 DOI: 10.1088/1361-6560/abf9dd] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Accepted: 04/20/2021] [Indexed: 11/11/2022]
Abstract
Fixed-gantry radiation therapy has been proposed as a low-cost alternative to the conventional rotating-gantry radiation therapy, that may help meet the rising global treatment demand. Fixed-gantry systems require gravitational motion compensated reconstruction algorithms to produce cone-beam CT (CBCT) images of sufficient quality for image guidance. The aim of this work was to adapt and investigate five CBCT reconstruction algorithms for fixed-gantry CBCT images. The five algorithms investigated were Feldkamp-Davis-Kress (FDK), prior image constrained compressed sensing (PICCS), gravitational motion compensated FDK (GMCFDK), motion compensated PICCS (MCPICCS) (a novel CBCT reconstruction algorithm) and simultaneous motion estimation and iterative reconstruction (SMEIR). Fixed-gantry and rotating-gantry CBCT scans were acquired of 3 rabbits, with the rotating-gantry scans used as a reference. Projections were sorted into rotation bins, based on the angle of rotation of the rabbit during image acquisition. The algorithms were compared using the structural similarity index measure root mean square error, and reconstruction time. Evaluation of the reconstructed volumes showed that, when compared with the reference rotating-gantry volume, the conventional FDK algorithm did not accurately reconstruct fixed-gantry CBCT scans. Whilst the PICCS reconstruction algorithm reduced some motion artefacts, the motion estimation reconstruction methods (GMCFDK, MCPICCS and SMEIR) were able to greatly reduce the effect of motion artefacts on the reconstructed volumes. This finding was verified quantitatively, with GMCFDK, MCPICCS and SMEIR reconstructions having RMSE 17%-19% lower and SSIM 1% higher than a conventional FDK. However, all motion compensated fixed-gantry CBCT reconstructions had a 56%-61% higher RMSE and 1.5% lower SSIM than FDK reconstructions of conventional rotating-gantry CBCT scans. The results show that motion compensation is required to reduce motion artefacts for fixed-gantry CBCT reconstructions. This paper further demonstrates the feasibility of fixed-gantry CBCT scans, and the ability of CBCT reconstruction algorithms to compensate for motion due to horizontal rotation.
Collapse
Affiliation(s)
- Mark Gardner
- ACRF Image X Institute, The University of Sydney, Eveleigh, NSW 2015, Australia
| | - Owen Dillon
- ACRF Image X Institute, The University of Sydney, Eveleigh, NSW 2015, Australia
| | - Chun-Chien Shieh
- ACRF Image X Institute, The University of Sydney, Eveleigh, NSW 2015, Australia.,Sydney Neuroimaging Analysis Centre, Camperdown, NSW 2050, Australia
| | - Ricky O'Brien
- ACRF Image X Institute, The University of Sydney, Eveleigh, NSW 2015, Australia
| | - Emily Debrot
- ACRF Image X Institute, The University of Sydney, Eveleigh, NSW 2015, Australia
| | - Jeffrey Barber
- Western Sydney Local Health District, Blacktown, NSW 2148, Australia
| | - Verity Ahern
- Western Sydney Local Health District, Blacktown, NSW 2148, Australia
| | - Peter Bennett
- Faculty of Science, The University of Sydney, Camperdown, NSW 2006, Australia
| | - Soo-Min Heng
- Nelune Comprehensive Cancer Centre, Randwick, NSW 2031, Australia
| | - Stéphanie Corde
- Nelune Comprehensive Cancer Centre, Randwick, NSW 2031, Australia
| | - Michael Jackson
- Nelune Comprehensive Cancer Centre, Randwick, NSW 2031, Australia
| | - Paul Keall
- ACRF Image X Institute, The University of Sydney, Eveleigh, NSW 2015, Australia
| |
Collapse
|