1
|
Ford P, Cheung AR, Khan MS, Rollo G, Paidy S, Hutchinson M, Chaudhry R. Anesthetic Techniques for Ablation in Atrial Fibrillation: A Comparative Review. J Cardiothorac Vasc Anesth 2024; 38:2754-2760. [PMID: 39164166 DOI: 10.1053/j.jvca.2024.05.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 04/15/2024] [Accepted: 05/02/2024] [Indexed: 08/22/2024]
Abstract
Atrial fibrillation, the most prevalent cardiac arrhythmia, has witnessed significant advancements in treatment modalities, transitioning from invasive procedures like the maze procedure to minimally invasive catheter ablation techniques. This review focuses on recent improvements in anesthetic approaches that enhance outcomes in catheter atrial fibrillation ablation. We highlight the efficacy of contact force sensing catheters with steerable introducer sheaths, which outperform traditional catheters by ensuring more effective contact time and lesion formation. Comparing general anesthesia with conscious sedation, we find that general anesthesia provides superior catheter stability due to reduced respiratory variability, resulting in more effective lesion formation, and reduced pulmonary vein reconnection. The use of high-frequency jet ventilation under general anesthesia, delivering low tidal volumes, effectively minimizes left atrial movement, decreasing catheter displacement and procedure time, and reducing recurrence in paroxysmal atrial fibrillation. An alternative, high-frequency low tidal volume ventilation using conventional ventilators, also shows improved catheter stability and lesion durability compared to traditional ventilation methods. However, a detailed comparative study of high-frequency jet ventilation, high-frequency low tidal volume ventilation, and conventional mechanical ventilation in catheter ablation for atrial fibrillation is lacking. This review emphasizes the need for such studies to identify optimal anesthetic techniques, potentially enhancing patient outcomes in atrial fibrillation treatment. Our findings suggest that careful selection of anesthetic methods, including ventilation strategies, plays a crucial role in the success of catheter ablation for atrial fibrillation, warranting further research for evidence-based practice.
Collapse
Affiliation(s)
- Paul Ford
- Banner University Medical Center, Department of Anesthesiology and Pain Medicine, University of Arizona COM-T, Tucson, Arizona
| | - Andrew Russell Cheung
- Banner University Medical Center, Department of Anesthesiology and Pain Medicine, University of Arizona COM-T, Tucson, Arizona
| | - Maaz Shah Khan
- Banner University Medical Center, Department of Anesthesiology and Pain Medicine, University of Arizona COM-T, Tucson, Arizona
| | - Gabriella Rollo
- Banner University Medical Center, Department of Anesthesiology and Pain Medicine, University of Arizona COM-T, Tucson, Arizona
| | - Samata Paidy
- Banner University Medical Center, Department of Anesthesiology and Pain Medicine, University of Arizona COM-T, Tucson, Arizona
| | - Mathew Hutchinson
- Banner University Medical Center, Division of Cardiology, Department of Medicine, University of Arizona COM-T, Tucson, Arizona
| | - Rabail Chaudhry
- Banner University Medical Center, Department of Anesthesiology and Pain Medicine, University of Arizona COM-T, Tucson, Arizona.
| |
Collapse
|
2
|
Graur A, Mercaldo ND, Simon J, Alici C, Saenger JA, Cahalane AM, Vazquez R, Fintelmann FJ. High-Frequency Jet Ventilation Versus Spontaneous Respiration for Percutaneous Cryoablation of Lung Tumors: Comparison of Adverse Events and Procedural Efficiency. AJR Am J Roentgenol 2024; 222:e2330557. [PMID: 38264999 DOI: 10.2214/ajr.23.30557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2024]
Abstract
BACKGROUND. High-frequency jet ventilation (HFJV) facilitates accurate probe placement in percutaneous ablation of lung tumors but may increase risk for adverse events, including systemic air embolism. OBJECTIVE. The purpose of this study was to compare major adverse events and procedural efficiency of percutaneous lung ablation with HFJV under general anesthesia to spontaneous respiration (SR) under moderate sedation. METHODS. This retrospective study included consecutive adults who underwent CT-guided percutaneous cryoablation of one or more lung tumors with HFJV or SR between January 1, 2017, and May 31, 2023. We compared major adverse events (Common Terminology Criteria for Adverse Events grade ≥ 3) within 30 days postprocedure and hospital length of stay (HLOS) of 2 days or more using logistic regression analysis. We compared procedure time, room time, CT guidance acquisition time, CT guidance radiation dose, total radiation dose, and pneumothorax using generalized estimating equations. RESULTS. Overall, 139 patients (85 women, 54 men; median age, 68 years) with 310 lung tumors (82% metastases) underwent 208 cryoablations (HFJV, n = 129; SR, n = 79). HFJV showed greater rates than SR for the treatment of multiple tumors per session (43% vs 19%, respectively; p = .02) and tumors in a nonperipheral location (48% vs 24%, p < .001). Major adverse event rate was 8% for HFJV and 5% for SR (p = .46). No systemic air embolism occurred. HLOS was 2 days or more in 17% of sessions and did not differ significantly between HFJV and SR (p = .64), including after adjusting for probe number per session, chronic obstructive pulmonary disease, and operator experience (p = .53). Ventilation modalities showed no significant difference in procedure time, CT guidance acquisition time, CT guidance radiation dose, or total radiation dose (all p > .05). Room time was longer for HFJV than SR (median, 154 vs 127 minutes, p < .001). For HFJV, the median anesthesia time was 136 minutes. Ventilation modalities did not differ in the frequencies of pneumothorax or pneumothorax requiring chest tube placement (both p > .05). CONCLUSION. HFJV appears to be as safe as SR but had longer room times. HFJV can be used in complex cases without significantly impacting HLOS of 2 days or more, procedure time, or radiation exposure. CLINICAL IMPACT. Selection of the ventilation modality during percutaneous lung ablation should be based on patient characteristics and anticipated procedural requirements as well as operator preference.
Collapse
Affiliation(s)
- Alexander Graur
- Department of Radiology, Division of Thoracic Imaging and Intervention, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
- Department of Radiology, Ludwig-Maximilians-University, Munich, Germany
| | | | - Judit Simon
- Department of Radiology, Division of Thoracic Imaging and Intervention, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| | - Cagatay Alici
- Department of Radiology, Division of Thoracic Imaging and Intervention, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| | - Jonathan A Saenger
- Department of Radiology, Division of Thoracic Imaging and Intervention, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
- Department of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Alexis M Cahalane
- Department of Radiology, Division of Thoracic Imaging and Intervention, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| | - Rafael Vazquez
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, MA
| | - Florian J Fintelmann
- Department of Radiology, Division of Thoracic Imaging and Intervention, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| |
Collapse
|
3
|
Uppot RN, Wah TM, Mueller PR. Percutaneous treatment of renal tumours. J Med Imaging Radiat Oncol 2023; 67:853-861. [PMID: 37417722 DOI: 10.1111/1754-9485.13553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Accepted: 06/15/2023] [Indexed: 07/08/2023]
Abstract
Image-guided ablation is an accepted treatment option in the management of renal cell carcinoma. Percutaneous renal ablation offers the possibility of minimally invasive treatment while attempting to preserve renal function. Over the past several years there have been advances in tools and techniques that have improved procedure safety and patient outcomes. This article provides an updated comprehensive review of percutaneous ablation in the management of renal cell carcinoma.
Collapse
Affiliation(s)
- Raul N Uppot
- Massachusetts General Hospital, Boston, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Tze Min Wah
- Department of Interventional Radiology, Faculty of Medicine, Leeds Institute of Medical Research, University of Leeds, Leeds, UK
- Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Peter R Mueller
- Massachusetts General Hospital, Boston, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
4
|
Wagner MG, Periyasamy S, Kutlu AZ, Pieper AA, Swietlik JF, Ziemlewicz TJ, Hall TL, Xu Z, Speidel MA, Jr FTL, Laeseke PF. An X-Ray C-Arm Guided Automatic Targeting System for Histotripsy. IEEE Trans Biomed Eng 2023; 70:592-602. [PMID: 35984807 PMCID: PMC9929026 DOI: 10.1109/tbme.2022.3198600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE Histotripsy is an emerging noninvasive, nonionizing and nonthermal focal cancer therapy that is highly precise and can create a treatment zone of virtually any size and shape. Current histotripsy systems rely on ultrasound imaging to target lesions. However, deep or isoechoic targets obstructed by bowel gas or bone can often not be treated safely using ultrasound imaging alone. This work presents an alternative x-ray C-arm based targeting approach and a fully automated robotic targeting system. METHODS The approach uses conventional cone beam CT (CBCT) images to localize the target lesion and 2D fluoroscopy to determine the 3D position and orientation of the histotripsy transducer relative to the C-arm. The proposed pose estimation uses a digital model and deep learning-based feature segmentation to estimate the transducer focal point relative to the CBCT coordinate system. Additionally, the integrated robotic arm was calibrated to the C-arm by estimating the transducer pose for four preprogrammed transducer orientations and positions. The calibrated system can then automatically position the transducer such that the focal point aligns with any target selected in a CBCT image. RESULTS The accuracy of the proposed targeting approach was evaluated in phantom studies, where the selected target location was compared to the center of the spherical ablation zones in post-treatment CBCTs. The mean and standard deviation of the Euclidean distance was 1.4 ±0.5 mm. The mean absolute error of the predicted treatment radius was 0.5 ±0.5 mm. CONCLUSION CBCT-based histotripsy targeting enables accurate and fully automated treatment without ultrasound guidance. SIGNIFICANCE The proposed approach could considerably decrease operator dependency and enable treatment of tumors not visible under ultrasound.
Collapse
|
5
|
Jet Ventilation Reduces Coronary Sinus Movement in Patients Undergoing Atrial Fibrillation Ablation: An Observational Crossover Study. J Pers Med 2023; 13:jpm13020186. [PMID: 36836420 PMCID: PMC9967483 DOI: 10.3390/jpm13020186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 01/18/2023] [Accepted: 01/18/2023] [Indexed: 01/25/2023] Open
Abstract
BACKGROUND One of the reasons that high-frequency jet ventilation (HFJV) is used is due to the near immobility of thoracic structures. However, no study has quantified the movements of cardiac structures during HFJV compared with normal mechanical ventilation. METHODS After ethical approval and written informed consent, we included 21 patients scheduled for atrial fibrillation ablation in this prospective crossover study. Each patient was ventilated with both normal mechanical ventilation and HFJV. During each ventilation mode, displacements of the cardiac structure were measured by the EnSite Precision mapping system using a catheter placed in the coronary sinus. RESULTS The median [Q1-Q4] displacement was 2.0 [0.6-2.8] mm during HFJV and 10.5 [9.3-13.0] mm during conventional ventilation (p < 0.000001). CONCLUSION This study quantifies the minimal movement of cardiac structures during HFJV compared to standard mechanical ventilation.
Collapse
|
6
|
Alvarez CK, Zweibel S, Stangle A, Panza G, May T, Marieb M. Anesthetic Considerations in the Electrophysiology Laboratory: A Comprehensive Review. J Cardiothorac Vasc Anesth 2023; 37:96-111. [PMID: 36357307 DOI: 10.1053/j.jvca.2022.10.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2022] [Revised: 10/02/2022] [Accepted: 10/10/2022] [Indexed: 11/06/2022]
Abstract
Catheter ablation procedures for arrhythmias or implantation and/or extraction of cardiac pacemakers can present many clinical challenges. It is imperative that there is clear communication and understanding between the anesthesiologist and electrophysiologist during the perioperative period regarding the mode of ventilation, hemodynamic considerations, and various procedural complications. This article provides a comprehensive narrative review of the anesthetic techniques and considerations for catheter ablation procedures, ventilatory modes using techniques such as high-frequency jet ventilation, and strategies such as esophageal deviation and luminal temperature monitoring to decrease the risk of esophageal injury during catheter ablation. Various hemodynamic considerations, such as the intraprocedural triaging of cardiac tamponade and fluid administration during catheter ablation, also are discussed. Finally, this review briefly highlights the early research findings on pulse-field ablation, a new and evolving ablation modality.
Collapse
Affiliation(s)
- Chikezie K Alvarez
- Hartford HealthCare Heart and Vascular Institute, Hartford, CT; University of Connecticut, Farmington, CT.
| | - Steven Zweibel
- Hartford HealthCare Heart and Vascular Institute, Hartford, CT
| | - Alexander Stangle
- Hartford HealthCare Heart and Vascular Institute, Hartford, CT; University of Connecticut, Farmington, CT
| | - Gregory Panza
- Hartford HealthCare Heart and Vascular Institute, Hartford, CT; University of Connecticut, Farmington, CT
| | - Thomas May
- Hartford HealthCare Heart and Vascular Institute, Hartford, CT
| | - Mark Marieb
- Hartford HealthCare Heart and Vascular Institute, Hartford, CT; Griffin Hospital, Derby, CT
| |
Collapse
|
7
|
Salih T, Elgie L, Hari B, Williams B, Thomas RM, Bandula S, Walkden M, Sultan P, McPherson K, Jenkins K. In-Circuit High-Frequency Jet Ventilation for Radiological Tumor Ablation: A Case Series. A A Pract 2022; 16:e01608. [DOI: 10.1213/xaa.0000000000001608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
8
|
Kadado AJ, Gobeil K, Fakhoury F, Pervaiz A, Chalhoub F. Very low tidal volume, high-frequency ventilation in atrial fibrillation ablation: a systematic review. J Interv Card Electrophysiol 2022; 64:539-543. [PMID: 35029769 DOI: 10.1007/s10840-022-01123-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Accepted: 01/06/2022] [Indexed: 10/19/2022]
Abstract
BACKGROUND Ventilation strategies in atrial fibrillation ablation affect procedure outcomes by influencing catheter stability. Studies have highlighted favorable atrial fibrillation (AF) ablation outcomes with the use of high-frequency jet ventilation (HFJV) which has been shown to improve lesion durability, energy delivery, and tissue contact. However, this mode of ventilation is not readily available. In this systematic review, we highlight the available data on the use of very low tidal volume, high-frequency ventilation using standard ventilators that aim to provide settings similar to HFJV during AF ablations. METHODS Using a combination of search terms in databases and manual searches in bibliographies of identified articles, we reviewed all published data reported in the English language on the use of very low tidal volume with high-frequency ventilation during atrial fibrillation ablation. RESULTS A total of 4 manuscripts were identified; 3 cohort studies and 1 case report. The utilization of standard ventilators with a high-frequency, very low tidal volume ventilation strategy appears to closely mimic the catheter stability benefits that HFJV ventilators provide. Across the 3 cohort identified studies, the use of this ventilation strategy was associated with improved catheter stability, tissue contact, and a decrease in radiofrequency time. No increased risk was identified compared to standard ventilation. CONCLUSION With a purpose of limiting thoracic excursion and cardiac movement, limited and sparse studies have shown improved outcomes with a very low tidal volume, high-frequency ventilation strategy. Additional studies are needed to solidify this easily accessible and widely available mode of ventilation.
Collapse
Affiliation(s)
- Anis John Kadado
- Department of Cardiology, UMass Chan Medical School-Baystate, 759 Chestnut Street, Springfield, MA, 01199, USA.
| | - Kyle Gobeil
- Department of Cardiology, UMass Chan Medical School-Baystate, 759 Chestnut Street, Springfield, MA, 01199, USA
| | - Fadi Fakhoury
- Department of Anesthesiology and Pain Management, Centre Hospitalo-Universitaire Caremeau, Nimes, France
| | - Abdullah Pervaiz
- Department of Cardiology, UMass Chan Medical School-Baystate, 759 Chestnut Street, Springfield, MA, 01199, USA
| | - Fadi Chalhoub
- Department of Cardiology, UMass Chan Medical School-Baystate, 759 Chestnut Street, Springfield, MA, 01199, USA
| |
Collapse
|
9
|
Babapoor-Farrokhran S, Alzubi J, Port Z, Khraisha O, Mainigi SK. Utility of High-frequency Jet Ventilation in Atrial Fibrillation Ablation. J Innov Card Rhythm Manag 2021; 12:4590-4593. [PMID: 34327044 PMCID: PMC8313182 DOI: 10.19102/icrm.2021.120708] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2020] [Accepted: 01/07/2021] [Indexed: 01/19/2023] Open
Abstract
Atrial fibrillation (AF) is the most common clinically significant arrhythmia that causes major morbidity and mortality. Catheter ablation focusing on pulmonary vein isolation is increasingly used for the treatment of symptomatic AF. Advances in ablation technologies and improved imaging and mapping have enhanced treatment efficiency but only modestly improved the efficacy. Another-but less commonly used-technology that can have a favorable impact involves enhancing the catheter-tissue contact by manipulating respiration to promote improved catheter stability and optimal contact. High-frequency jet ventilation (HFJV) is a mode of ventilation that can reduce respiratory movements to almost apneic conditions. In this review article, we aimed to highlight different studies, review the current literature regarding the utility of HFJV in AF ablation, and discuss the safety and efficacy of this approach relative to that of conventional ventilation.
Collapse
Affiliation(s)
| | - Jafar Alzubi
- Department of Medicine, Division of Cardiology, Einstein Medical Center, Philadelphia, PA, USA
| | - Zachary Port
- Department of Medicine, Division of Cardiology, Einstein Medical Center, Philadelphia, PA, USA
| | - Ola Khraisha
- Department of Medicine, Division of Cardiology, Einstein Medical Center, Philadelphia, PA, USA
| | - Sumeet K. Mainigi
- Department of Medicine, Division of Cardiology, Einstein Medical Center, Philadelphia, PA, USA
- Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA
| |
Collapse
|
10
|
Alnadhari I, Ali O, Abdeljaleel O, Sampige VRP, Shamsodini A, Salah M. Ergonomics and Surgeon Comfort During Flexible Ureteroscopy. Res Rep Urol 2021; 13:415-424. [PMID: 34235098 PMCID: PMC8254182 DOI: 10.2147/rru.s317347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Accepted: 06/05/2021] [Indexed: 11/23/2022] Open
Abstract
The technological advancements of flexible ureteroscopy (FURS) and its accessories have resulted in broadening its indications to include the management of complex renal stones, with long operative time. The surgeon's understanding about the ergonomics of the ureteroscopes and their cognizance of the operation theatre layout helps to improve their performance, including the surgical outcomes. This paper will describe the ergonomics that are involved in conducting FURS which in turn will aid in developing a more conducive surgical environment for the surgeon during the procedure, based on scientific literature review and expert opinions in high-volume centres. Proper surgeon position, well-arranged operation theatre layout, monitor and pedal position, anaesthesia type, and surgical team are important factors to decrease musculoskeletal strains for surgeons and increase work efficiency. Different types of flexible ureteroscope have different characters and knowing these special characters leads to better ergonomics during surgery. Robotic-assisted FURS have shown good safety and ergonomics in clinical application.
Collapse
Affiliation(s)
- Ibrahim Alnadhari
- Urology Section, Department of Surgery, Al Wakra Hospital, Hamad Medical Corporation, Al Wakra, Qatar
| | - Omar Ali
- Urology Section, Department of Surgery, Al Wakra Hospital, Hamad Medical Corporation, Al Wakra, Qatar
| | - Osama Abdeljaleel
- Urology Section, Department of Surgery, Al Wakra Hospital, Hamad Medical Corporation, Al Wakra, Qatar
| | | | - Ahmad Shamsodini
- Urology Section, Department of Surgery, Al Wakra Hospital, Hamad Medical Corporation, Al Wakra, Qatar
| | - Morshed Salah
- Urology Section, Department of Surgery, Hazm Mebaireek General Hospital, Hamad Medical Corporation, Doha, Qatar
| |
Collapse
|
11
|
Prud'homme C, Teriitehau C, Adam J, Kyaw Tun J, Roux C, Hakime A, Delpla A, Deschamps F, de Baere T, Tselikas L. Lung microwave ablation - an in vivo swine tumor model experiment to evaluate ablation zones. Int J Hyperthermia 2021; 37:879-886. [PMID: 32689829 DOI: 10.1080/02656736.2020.1787530] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
PURPOSE To evaluate microwave ablation (MWA) algorithms, comparing pulsed and continuous mode in an in vivo lung tumor mimic model. MATERIALS AND METHODS A total of 43 lung tumor-mimic models of 1, 2 or 3 cm were created in 11 pigs through an intra-pulmonary injection of contrast-enriched minced muscle. Tumors were ablated under fluoroscopic and 3D-CBCT-guidance using a single microwave antenna. Continuous (CM) and pulsed mode (PM) were used. According to tumor size, 3 different algorithms for both continuous and pulsed mode were used. The ablation zones were measured using post-procedural 3D-CBCT and on pathologic specimens. RESULTS Two radiologists measured the ablation zones on CBCT and they significantly correlated with macroscopic and microscopic pathological findings: r = 0.75 and 0.74 respectively (p < 0.0001) (inter-observer correlation r = 0.9). For 1, 2 and 3 cm tumors mimics lesions (TMLs), mean maximal and transverse ablation diameters were 3.6 [Formula: see text] 0.3 × 2.2 [Formula: see text] 0.3 cm; 4.1 [Formula: see text] 0.5 × 2.6 [Formula: see text] 0.3 cm and 4.8 [Formula: see text] 0.3 × 3.2 [Formula: see text] 0.3 cm respectively using CM; And, 3.0 [Formula: see text] 0.2 × 2.1 [Formula: see text] 0.2 cm; 4.0 [Formula: see text] 0.4 × 2.7 [Formula: see text] 0.4 cm and 4.6 [Formula: see text] 0.4 × 3.2 [Formula: see text] 0.4 cm respectively for PM, without any significant difference except for 1 cm TMLs treated by PM ablation which were significantly smaller (p = 0.009) The sphericity index was 1.6, 1.6, 1.5 and 1.4, 1.5, 1.4 at 1, 2 and 3 cm for CM and PM respectively, p = 0.07, 0.14 and 0.13 for 1, 2 and 3 cm tumors mimics. CONCLUSION Microwave ablation for 1-3 cm lung tumors were successfully realized but with a moderate reproducibility rate, using either CM or PM. Immediate post ablation CBCT can accurately evaluate ablation zones.
Collapse
Affiliation(s)
- Clara Prud'homme
- Département d' Anesthésie, Chirurgie et Interventionel, Gustave Roussy, Villejuif, France
| | - Christophe Teriitehau
- Département d' Anesthésie, Chirurgie et Interventionel, Gustave Roussy, Villejuif, France
| | - Julien Adam
- Department of Pathology, Gustave Roussy, Villejuif, France
| | - Jimmy Kyaw Tun
- Interventional Radiology Department, Barts Health NHS Trust, London, UK
| | - Charles Roux
- Département d' Anesthésie, Chirurgie et Interventionel, Gustave Roussy, Villejuif, France
| | - Antoine Hakime
- Département d' Anesthésie, Chirurgie et Interventionel, Gustave Roussy, Villejuif, France
| | - Alexandre Delpla
- Département d' Anesthésie, Chirurgie et Interventionel, Gustave Roussy, Villejuif, France
| | - Fréderic Deschamps
- Département d' Anesthésie, Chirurgie et Interventionel, Gustave Roussy, Villejuif, France
| | - Thierry de Baere
- Département d' Anesthésie, Chirurgie et Interventionel, Gustave Roussy, Villejuif, France.,Université Paris-Saclay, Saint-Aubin, France
| | - Lambros Tselikas
- Département d' Anesthésie, Chirurgie et Interventionel, Gustave Roussy, Villejuif, France
| |
Collapse
|
12
|
Accuracy of Electrode Placement in IRE Treatment with Navigated Guidance. Cardiovasc Intervent Radiol 2021; 44:968-975. [PMID: 33474604 PMCID: PMC8172499 DOI: 10.1007/s00270-020-02762-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Accepted: 12/24/2020] [Indexed: 01/03/2023]
Abstract
Purpose Evaluate the accuracy of multiple electrode placements in IRE treatment of liver tumours using a stereotactic CT-based navigation system. Method Analysing data from all IRE treatments of liver tumours at one institution until 31 December 2018. Comparing planned with validated electrode placement. Analysing lateral and angular errors and parallelism between electrode pairs Results Eighty-four tumours were treated in 60 patients. Forty-six per cent were hepatocellular carcinoma, and 36% were colorectal liver metastases. The tumours were located in all segments of the liver. Data were complete from 51 treatments. Two hundred and six electrodes and 336 electrode pairs were analysed. The median lateral and angular error, comparing planned and validated electrode placement, was 3.6 mm (range 0.2–13.6 mm) and 3.1° (range 0°–16.1°). All electrodes with a lateral error >10 mm were either re-positioned or excluded before treatment. The median angle between the electrode pairs was 3.8° (range 0.3°–17.2°). There were no electrode placement-related complications. Conclusion The use of a stereotactic CT-based system for navigation of electrode placement in IRE treatment of liver tumours is safe, accurate and user friendly.
Collapse
|
13
|
Longo KC, Zlevor AM, Laeseke PF, Swietlik JF, Knott EA, Rodgers AC, Mao L, Zhang X, Xu Z, Wagner MG, Periyasamy S, Lee FT, Ziemlewicz TJ. Histotripsy Ablations in a Porcine Liver Model: Feasibility of Respiratory Motion Compensation by Alteration of the Ablation Zone Prescription Shape. Cardiovasc Intervent Radiol 2020; 43:1695-1701. [PMID: 32676957 DOI: 10.1007/s00270-020-02582-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 06/26/2020] [Indexed: 01/11/2023]
Abstract
BACKGROUND Previous human-scale porcine liver model studies of histotripsy have resulted in ablation zones elongated in the cranial-caudal (CC) dimension due to uninterrupted respiratory motion during the ablation procedure. PURPOSE The purpose of this study is to compensate for elongation of hepatic histotripsy ablation zones in the cranial-caudal (CC) dimension caused by respiratory motion by prescribing ellipsoid-shaped ablations. METHODS Six female swine underwent 12 hepatic histotripsy ablations using a prototype clinical histotripsy system under general anesthesia. Each animal received two ablation zones prescribed as either an ellipsoid (2.5 cm (AP) × 2.5 cm (ML) × 1.7 cm (CC), prescribed volume = 5.8 cc) or a sphere (2.5 cm all dimensions, prescribed volume 8.2 cc). Ventilatory tidal volume was held constant at 400 cc for all ablations. Post-procedure MRI was followed by sacrifice and gross and microscopic histology. RESULTS Ablations on MRI were slightly larger than prescribed in all dimensions. Ellipsoid plan ablations (2.8 × 3.0 × 3.1 cm, volume 13.2 cc, sphericity index 0.987) were closer to prescribed volume than spherical plan ablations (2.9 × 3.1 × 3.7 cm, volume 17.1 cc, sphericity index 0.953). Ellipsoid plan ablations were more spherical than sphere plan ablations, but the difference did not reach statistical significance (p = .0.06). Pathologic analysis confirmed complete necrosis within the center of each ablation zone with no widening of the zone of partial ablation on the superior and inferior as compared to the lateral borders (p = .0.22). CONCLUSION Altering ablation zone prescription shape when performing hepatic histotripsy ablations can partially mitigate respiratory motion effects to achieve the desired ablation shape and volume.
Collapse
Affiliation(s)
- Katherine C Longo
- Department of Radiology, University of Wisconsin, 600 Highland Ave., Madison, WI, 53024, USA
| | - Annie M Zlevor
- Department of Radiology, University of Wisconsin, 600 Highland Ave., Madison, WI, 53024, USA
| | - Paul F Laeseke
- Department of Radiology, University of Wisconsin, 600 Highland Ave., Madison, WI, 53024, USA
| | - John F Swietlik
- Department of Radiology, University of Wisconsin, 600 Highland Ave., Madison, WI, 53024, USA
| | - Emily A Knott
- Department of Radiology, University of Wisconsin, 600 Highland Ave., Madison, WI, 53024, USA
| | - Allison C Rodgers
- Department of Medicine, University of Wisconsin, 600 Highland Ave., Madison, WI, 53024, USA
| | - Lu Mao
- Department of Biostatistics and Medical Informatics, University of Wisconsin, 600 Highland Ave., Madison, WI, 53024, USA
| | - Xiaofei Zhang
- Department of Pathology, University of Wisconsin, 600 Highland Ave., Madison, WI, 53024, USA
| | - Zhen Xu
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Martin G Wagner
- Department of Medical Physics, University of Wisconsin, 600 Highland Ave., Madison, WI, 53024, USA
| | - Sarvesh Periyasamy
- Department of Radiology, University of Wisconsin, 600 Highland Ave., Madison, WI, 53024, USA.,Department of Biomedical Engineering, University of Wisconsin, 600 Highland Ave., Madison, WI, 53024, USA
| | - Fred T Lee
- Department of Radiology, University of Wisconsin, 600 Highland Ave., Madison, WI, 53024, USA.,Department of Urology, University of Wisconsin, 600 Highland Ave., Madison, WI, 53024, USA.,Department of Biomedical Engineering, University of Wisconsin, 600 Highland Ave., Madison, WI, 53024, USA
| | - Timothy J Ziemlewicz
- Department of Radiology, University of Wisconsin, 600 Highland Ave., Madison, WI, 53024, USA.
| |
Collapse
|
14
|
Comparison of different methods for lung immobilization in an animal model. Radiother Oncol 2020; 150:151-158. [PMID: 32580000 DOI: 10.1016/j.radonc.2020.06.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 05/28/2020] [Accepted: 06/17/2020] [Indexed: 12/25/2022]
Abstract
BACKGROUND AND PURPOSE Respiratory-induced motion introduces uncertainties in the delivery of dose in radiotherapy treatments. Various methods are used clinically, e.g. breath-holding, while there is limited experience with other methods such as apneic oxygenation and high frequency jet ventilation (HFJV). This study aims to compare the latter approaches for lung immobilization and their clinical impact on gas exchange in an animal model. MATERIALS AND METHODS Two radiopaque tumor surrogate markers (TSM) were placed in the central (cTSM) and peripheral (dTSM) regions of the lungs in 9 anesthetized and muscle relaxed pigs undergoing 3 ventilatory interventions (1) HFJV at rates of 200 (JV200), 300 (JV300) and 400 (JV400) min-1; (2) apnea at continuous positive airway pressure (CPAP) levels of 0, 8 and 16 cmH2O; (3) conventional mechanical ventilation (CMV) as reference mode. cTSM and dTSM were visualized using fluoroscopy and their coordinates were computed. The ventilatory pattern was registered, and oxygen and carbon dioxide (pCO2) partial pressures were measured. RESULTS The highest range of TSM motion, and ventilation was found during CMV, the lowest during apnea. During HFJV the amount of motion varied inversely with increasing frequency. The reduction of TSM motion at JV300, JV400 and all CPAP levels came at the cost of increased pCO2, however the relatively low frequency of 200 min-1 for HFJV was the only ventilatory setting that enabled adequate CO2 removal. CONCLUSION In this model, HFJV at 200 min-1 was the best compromise between immobilization and gas exchange for sessions of 10-min duration.
Collapse
|
15
|
Aizer A, Qiu JK, Cheng AV, Wu PB, Barbhaiya CR, Jankelson L, Linton P, Bernstein SA, Park DS, Holmes DS, Chinitz LA. Rapid pacing and high-frequency jet ventilation additively improve catheter stability during atrial fibrillation ablation. J Cardiovasc Electrophysiol 2020; 31:1678-1686. [PMID: 32314841 DOI: 10.1111/jce.14507] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Revised: 04/08/2020] [Accepted: 04/16/2020] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Catheter stability during atrial fibrillation ablation is associated with higher ablation success rates. Rapid cardiac pacing and high-frequency jet ventilation (HFJV) independently improve catheter stability. Simultaneous modulation of cardiac and respiratory motion has not been previously studied. The objective of this study was to determine the effect of simultaneous heart rate and respiratory rate modulation on catheter stability. METHODS Forty patients undergoing paroxysmal atrial fibrillation ablation received ablation lesions at 15 prespecified locations (12 left atria, 3 right atria). Patients were randomly assigned to undergo rapid atrial pacing for either the first or the second half of each lesion. Within each group, half of the patients received HFJV and the other half standard ventilation. Contact force and ablation data for all lesions were compared among the study groups. Standard deviation of contact force was the primary endpoint defined to examine contact force variability. RESULTS Lesions with no pacing and standard ventilation had the greatest contact force standard deviation (5.86 ± 3.08 g), compared to lesions with pacing and standard ventilation (5.45 ± 3.28 g; P < .01) or to lesions with no pacing and HFJV (4.92 ± 3.00 g; P < .01). Lesions with both pacing and HFJV had the greatest reduction in contact force standard deviation (4.35 ± 2.81 g; P < .01), confirming an additive benefit of each maneuver. Pacing and HFJV together was also associated with a reduction in the proportion of lesions with excessive maximum contact force (P < .001). DISCUSSION Rapid pacing and HFJV additively improve catheter stability. Simultaneous pacing with HFJV further improves catheter stability over pacing or HFJV alone to optimize ablation lesions.
Collapse
Affiliation(s)
- Anthony Aizer
- The New York University Cardiac Electrophysiology Service, New York University School of Medicine, New York University Langone Health, New York, New York
| | - Jessica K Qiu
- The New York University Cardiac Electrophysiology Service, New York University School of Medicine, New York University Langone Health, New York, New York
| | - Austin V Cheng
- The New York University Cardiac Electrophysiology Service, New York University School of Medicine, New York University Langone Health, New York, New York
| | - Patrick B Wu
- The New York University Cardiac Electrophysiology Service, New York University School of Medicine, New York University Langone Health, New York, New York
| | - Chirag R Barbhaiya
- The New York University Cardiac Electrophysiology Service, New York University School of Medicine, New York University Langone Health, New York, New York
| | - Lior Jankelson
- The New York University Cardiac Electrophysiology Service, New York University School of Medicine, New York University Langone Health, New York, New York
| | - Patrick Linton
- The New York University Cardiac Electrophysiology Service, New York University School of Medicine, New York University Langone Health, New York, New York
| | - Scott A Bernstein
- The New York University Cardiac Electrophysiology Service, New York University School of Medicine, New York University Langone Health, New York, New York
| | - David S Park
- The New York University Cardiac Electrophysiology Service, New York University School of Medicine, New York University Langone Health, New York, New York
| | - Douglas S Holmes
- The New York University Cardiac Electrophysiology Service, New York University School of Medicine, New York University Langone Health, New York, New York
| | - Larry A Chinitz
- The New York University Cardiac Electrophysiology Service, New York University School of Medicine, New York University Langone Health, New York, New York
| |
Collapse
|
16
|
Pollet M, Jenny B, Mehta A, Howard A, Mathuria N. Ablation of Refractory Papillary Muscle Ventricular Tachycardia Warranting Multiple Adjunctive Ablation Techniques: A Combined Approach for Success. J Innov Card Rhythm Manag 2020; 11:3997-4003. [PMID: 32368372 PMCID: PMC7192147 DOI: 10.19102/icrm.2020.110206] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Accepted: 08/15/2019] [Indexed: 12/30/2022] Open
Abstract
A 27-year-old male presented to our institution with recurrent unifocal premature ventricular contraction/nonsustained ventricular tachycardia (VT) with associated cardiomyopathy. The patient had undergone three prior ablation procedures with continued arrhythmia. Mapping led to identification of the VT arising from the basal aspect of the left ventricular anterolateral papillary muscle. Conventional ablation techniques were unsuccessful. We incorporated adjunctive ablation techniques in this case that ultimately led to a successful outcome. The present discussion covers the roles of intracardiac echocardiography, induced apnea, and low-ionic irrigation.
Collapse
Affiliation(s)
- Mark Pollet
- Division of Cardiac Electrophysiology, Texas Heart Institute, Houston, TX, USA
| | - Ben Jenny
- Division of Cardiac Electrophysiology, Texas Heart Institute, Houston, TX, USA
| | - Adwait Mehta
- Division of Cardiac Electrophysiology, Texas Heart Institute, Houston, TX, USA
| | - Austin Howard
- Division of Cardiac Electrophysiology, Texas Heart Institute, Houston, TX, USA
| | - Nilesh Mathuria
- Division of Cardiac Electrophysiology, Texas Heart Institute, Houston, TX, USA
| |
Collapse
|
17
|
Vazquez R, Beermann SL, Fintelmann FJ, Mullen EM, Chitilian H. High-Frequency Jet Ventilation in the Prone Position to Facilitate Cryoablation of a Peridiaphragmatic Pulmonary Neoplasm: A Case Report. A A Pract 2020; 13:169-172. [PMID: 31045587 DOI: 10.1213/xaa.0000000000001024] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Percutaneous cryoablation of pulmonary tumors at the posterior lung base is challenging due to diaphragmatic motion and the requirement for prone positioning. High-frequency jet ventilation allows oxygenation and ventilation with minimal diaphragmatic movement. In this case report, we describe the use of high-frequency jet ventilation in the prone position to facilitate the cryoablation of a peridiaphragmatic pulmonary neoplasm.
Collapse
Affiliation(s)
- Rafael Vazquez
- From the Departments of Anesthesia, Critical Care, and Pain Medicine
| | | | | | - Eleanor M Mullen
- From the Departments of Anesthesia, Critical Care, and Pain Medicine
| | - Hovig Chitilian
- From the Departments of Anesthesia, Critical Care, and Pain Medicine
| |
Collapse
|
18
|
Boatta E, Cazzato RL, De Marini P, Canuet M, Garnon J, Heger B, Bernmann TM, Ramamurthy N, Jahn C, Lopez M, Gangi A. Embolisation of pulmonary arteriovenous malformations using high-frequency jet ventilation: benefits of minimising respiratory motion. Eur Radiol Exp 2019; 3:26. [PMID: 31286281 PMCID: PMC6614221 DOI: 10.1186/s41747-019-0103-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2019] [Accepted: 05/28/2019] [Indexed: 01/20/2023] Open
Abstract
Background To evaluate patient radiation dose and procedural duration recorded during pulmonary arteriovenous malformation (PAVM) embolisation performed using high-frequency jet ventilation (HFJV) as compared with conventional intermittent positive pressure ventilation (IPPV) Methods Patients undergoing PAVM embolisation with HFJV assistance after April 2017 were retrospectively identified as group A, and those treated with IPPV before April 2017 as group B. Primary outcomes were patient radiation dose and procedural duration between groups A and B. Secondary outcomes were difference in diaphragmatic excursion between groups A and B, in group A with/without HFJ assistance, technical/clinical success, and complications. Results Twelve PAVMs were embolised in 5 patients from group A, and 15 PAVMs in 10 patients from group B. Mean patient radiation was significantly lower in group A than in group B (54,307 ± 33,823 mGy cm2 [mean ± standard deviation] versus 100,704 ± 43,930 mGy cm2; p = 0.022). Procedural duration was 33.4 ± 16.1 min in group A versus 57.4 ± 14.9 min in group B (p = 0.062). Diaphragmatic excursion was significantly lower in group A (1.3 ± 0.4 mm) than in group B (19.7 ± 5.2 mm; p < 0.001) and lower with near statistical significance in group A with HFJV than without HFJV (1.3 ± 0.4 mm versus 10.9 ± 3.1 mm; p = 0.062). Technical and clinical success was 100% in both groups, without relevant complications. Conclusion HFJV-assisted PAVM embolisation is a safe, feasible technique resulting in reduced patient radiation doses and procedural time.
Collapse
|
19
|
Barbhaiya CR, Knotts RJ, Bockstall K, Bernstein S, Park D, Holmes D, Aizer A, Chinitz LA. Contact-force radiofrequency ablation of non-paroxysmal atrial fibrillation: improved outcomes with increased experience. J Interv Card Electrophysiol 2019; 58:69-75. [PMID: 31707533 DOI: 10.1007/s10840-019-00618-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2019] [Accepted: 08/27/2019] [Indexed: 01/13/2023]
Abstract
INTRODUCTION Clinical trials have failed to reliably show improved outcomes with utilization of contact-force sensing (CFS) radiofrequency (RF) ablation catheters. It is unknown whether the unfavorable outcomes observed in these trials are attributable to inexperience with CFS technology. OBJECTIVES To compare catheter ablation outcomes of stepwise linear ablation with versus without CFS technology and to assess the impact of operator experience with CFS technology on procedural outcomes. METHODS Clinical outcomes were evaluated in 228 consecutive NPAF patients undergoing first-time left atrial ablation using a stepwise linear approach. Arrhythmia recurrence was assessed using 2-week event monitors at 3-month intervals following index ablation. RESULTS A total of 228 patients were included in our study. There was no statistically significant difference in risk of recurrent atrial arrhythmias at 12 and 24 months between CFS and non-CFS patients (p = 0.5 and p = 0.169). The time to recurrence of atrial arrhythmias at 24 months in the second half of CFS patients was significantly lower when compared to both the first half of CFS patients (p = 0.002) and non-CFS patients (p = 0.005). CONCLUSION While there was no difference in overall outcomes between CFS and non-CFS ablation using a stepwise linear approach in patients with NPAF, procedural efficacy of the second half of CFS patients was significantly improved compared to both the first half of CFS patients and all non-CFS patients. Lack of benefit seen in clinical trials using CFS technology may be related to operator inexperience with CFS ablation catheters at the time of the trials.
Collapse
Affiliation(s)
- Chirag R Barbhaiya
- Leon H. Charney Division of Cardiology, New York University Langone Health, New York University School of Medicine, 550 1st Avenue, New York, NY, 10016, USA.
| | - Robert J Knotts
- Leon H. Charney Division of Cardiology, New York University Langone Health, New York University School of Medicine, 550 1st Avenue, New York, NY, 10016, USA
| | - Katy Bockstall
- Leon H. Charney Division of Cardiology, New York University Langone Health, New York University School of Medicine, 550 1st Avenue, New York, NY, 10016, USA
| | - Scott Bernstein
- Leon H. Charney Division of Cardiology, New York University Langone Health, New York University School of Medicine, 550 1st Avenue, New York, NY, 10016, USA
| | - David Park
- Leon H. Charney Division of Cardiology, New York University Langone Health, New York University School of Medicine, 550 1st Avenue, New York, NY, 10016, USA
| | - Douglas Holmes
- Leon H. Charney Division of Cardiology, New York University Langone Health, New York University School of Medicine, 550 1st Avenue, New York, NY, 10016, USA
| | - Anthony Aizer
- Leon H. Charney Division of Cardiology, New York University Langone Health, New York University School of Medicine, 550 1st Avenue, New York, NY, 10016, USA
| | - Larry A Chinitz
- Leon H. Charney Division of Cardiology, New York University Langone Health, New York University School of Medicine, 550 1st Avenue, New York, NY, 10016, USA
| |
Collapse
|
20
|
Rodrigues JT, Oliveira C, Ferreira AP. Ventilação a jato de alta frequência ‐ uma nova abordagem no manejo da anestesia para ressonância magnética em cardiologia pediátrica: série de casos. Braz J Anesthesiol 2019; 69:626-630. [DOI: 10.1016/j.bjan.2019.08.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2019] [Revised: 08/01/2019] [Accepted: 08/20/2019] [Indexed: 10/25/2022] Open
|
21
|
Rodrigues JT, Oliveira C, Ferreira AP. High frequency jet ventilator ‒ a new approach in the management of anesthesia for pediatric cardiac Magnetic Resonance Imaging: case series. BRAZILIAN JOURNAL OF ANESTHESIOLOGY (ENGLISH EDITION) 2019. [PMID: 31796302 PMCID: PMC9391913 DOI: 10.1016/j.bjane.2019.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Background and objectives Cardiac Magnetic Resonance Imaging (MRI) is a technique used for evaluation of children with congenital heart diseases. General anesthesia ensures immobility, particularly in uncooperative patients. However, chest wall movements can limit good quality scans. Prolonged apnea may be necessary to decrease respiratory motion artefacts, potentially leading to hypoxemia and other adverse events. The use of a high frequency jet ventilator may be a solution avoiding chest wall movements. Case report We report four cases of pediatric patients, ASA II, aged between 4 and 15 years-old, scheduled for cardiac MRI. General anesthesia was proposed and parental informed consent was obtained. After general anesthesia was induced, an uncuffed endotracheal tube was inserted. Then, a 7Fr × 40 cm catheter was placed through the endotracheal tube. The proximal outlet of the catheter was attached through a connecting tube to a high frequency jet ventilator (Monsoon III®, Acutronic Medical Systems). Good quality MRI images were obtained. At the end of the procedures, we observed increased salivation and increased end-tidal CO2 (60–70 mmHg), in all patients. The patients were extubated after normocapnia was achieved and neuromuscular blockade reversed. Following appropriate recovery time, the four children were discharged home the same day. Conclusions This case series demonstrates that the use of a high frequency jet ventilator for cardiac MRI was feasible, safe, providing good quality cardiac imaging and avoiding anesthesia personnel to be inside the hazardous environment of MRI room. Future studies are needed to confirm its safety and efficiency in pediatric patients.
Collapse
|
22
|
Gadzhiev N, Oibolatov U, Kolotilov L, Parvanyan S, Akopyan G, Petrov S, Cottone CM, Sung J, Okhunov Z. Reducing kidney motion: optimizing anesthesia and combining respiratory support for retrograde intrarenal surgery: a pilot study. BMC Urol 2019; 19:61. [PMID: 31277626 PMCID: PMC6612185 DOI: 10.1186/s12894-019-0491-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 06/30/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND One of the greatest challenges presented with RIRS is the potential for movement of the stone within the operative field associated with diaphragm and chest respiratory excursions due to mechanical ventilation. To overcome this challenge, we propose in this pilot study a new general anesthesia technique combining high frequency jet ventilation (HFJV) with small volume mechanical ventilation (SVMV). Data regarding safety, feasibility and surgeons' impression was assessed. METHODS Patients undergoing RIRS for kidney stones from November 2017 to May 2018 were prospectively recruited to participate in the study. In each case after the beginning of general anesthesia (GA) with mechanical ventilation (MV) surgeons were asked to assess the mobility of the operative field and conditions for laser lithotripsy according to the developed questionnaire scale. The questionnaire consisted of 5 degrees of assessment of kidney mobility and each question was scored from 1 to 5, 1 being very mobile (extremely poor conditions for dusting) and 5 completely immobile (Ideal conditions for dusting). After the assessment GA was modified with combined respiratory support (CRS), reducing tidal volume and respiratory rate (small volume mechanical ventilation, SVMV) and applying in the same time transcatheter high frequency jet ventilation (HFJV) inside the closed circuit. After beginning of CRS, surgeons were once again asked to assess the mobility of the operative field and the conditions for laser lithotripsy. Main ventilation parameters were recorded and compared in both regimens. RESULTS A total of 38 patients were included in the study. The mean age was 49 (range 45-53) with a mean stone size of 10 mm (range 10-14) and Hounsfield unit of 1060 (range 930-1190). All patients underwent successful RIRS and no intraoperative complications occurred throughout the duration of the study. A statistically significant difference between ventilation parameters prior to and after CRS institution was detected in all cases, however their clinical impact was negligible. Despite this, assessment via the questionnaire scale point values varied significantly before and after the application of CRS and were 2.3 (2.1; 2.6) and 3.8 (3.7; 4.0) respectively (p < 0.001). CONCLUSIONS The novel combined respiratory approach consisting of HFJV and SVMV appears to provide better conditions for stone dusting through reduced respiratory kidney motion and is not associated with adverse health effects or complications. TRIAL REGISTRATION NCT03999255 , date of registration: 25th June 2019 (retrospectively registered).
Collapse
Affiliation(s)
- Nariman Gadzhiev
- Department of Urology, Pavlov First Saint Petersburg State Medical University, Lva Tolstogo 17, Saint-Petersburg, Russian Federation, 197342
| | - Ullubiy Oibolatov
- Department of Anesthesiology, The Nikiforov Center of Emergency Medicine, Optikov 54, Saint-Petersburg, Russian Federation, 197448
| | - Leonid Kolotilov
- Department of Anesthesiology, The Nikiforov Center of Emergency Medicine, Optikov 54, Saint-Petersburg, Russian Federation, 197448
| | - Sergei Parvanyan
- Department of Anesthesiology, The Nikiforov Center of Emergency Medicine, Optikov 54, Saint-Petersburg, Russian Federation, 197448
| | - Gagik Akopyan
- Department of Urology, Sechenov First Moscow State Medical University, Optikov 54, Saint-Petersburg, Russian Federation, 197448
| | - Sergei Petrov
- Department of Urology, Pavlov First Saint Petersburg State Medical University, Lva Tolstogo 17, Saint-Petersburg, Russian Federation, 197342
| | - Courtney M Cottone
- Department of Urology, University of California, Irvine, 333 City Boulevard West, Orange, CA, 92868, USA
| | - John Sung
- Department of Urology, University of California, Irvine, 333 City Boulevard West, Orange, CA, 92868, USA
| | - Zhamshid Okhunov
- Department of Urology, University of California, Irvine, 333 City Boulevard West, Orange, CA, 92868, USA.
| |
Collapse
|
23
|
Galmén K, Jakobsson JG, Freedman J, Harbut P. High Frequency Jet Ventilation during stereotactic ablation of liver tumours: an observational study on blood gas analysis as a measure of lung function during general anaesthesia. F1000Res 2019; 8:386. [PMID: 31583085 PMCID: PMC6753604 DOI: 10.12688/f1000research.18369.1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 04/01/2019] [Indexed: 11/20/2022] Open
Abstract
Background: Stereotactic ablation of tumours in solid organs is a promising curative procedure in clinical oncology. The technique demands minimal target organ movements to optimise tumour destruction and prevent injury to surrounding tissues. High frequency jet ventilation (HFJV) is a novel option during these procedures, reducing the respiratory-associated movements of the liver. The effects of HFJV via endotracheal catheter on gas exchange during liver tumour ablation is not well studied. Methods: The aim of this explorative study was to assess lung function and the effects on blood gas and lactate during HFJV in patients undergoing stereotactic liver ablation. Blood gases were analysed in 25 patients scheduled for stereotactic liver ablation under general anaesthesia pre-induction, every 15 minutes during HFJV and following extubation in the recovery room. The HFJV was set at fixed settings. Results: None of the patients developed hypoxia or signs of increased lactate production but a great variation in PaO 2/FiO 2 ratio was found; from 13.1 to 71.3. An increase in mean PaCO 2 was observed, from a baseline of 5.0 to a peak of 7.1 at 30 minutes (p <0.001) and a decrease was found in median pH, from a baseline of 7.44 to 7.31 at 15 minutes (p=0.03). We could not see any clear association between a decrease in PaO 2/FiO 2 ratio and PaCO 2 elevation. Conclusions: HFJV during general anaesthesia in patients undergoing stereotactic liver ablation is feasible and it did not cause hypoxemia or signs of increased lactate production. A reversible mild to moderate impairment of gas exchange was found during HFJV.
Collapse
Affiliation(s)
- Karolina Galmén
- Department of Anaesthesia and Intensive Care, Institution for Clinical Sciences, Karolinska Institutet, Danderyd University Hospital, Stockholm, 182 88, Sweden
| | - Jan G Jakobsson
- Department of Anaesthesia and Intensive Care, Institution for Clinical Sciences, Karolinska Institutet, Danderyd University Hospital, Stockholm, 182 88, Sweden
| | - Jacob Freedman
- Department of Surgery, Institution for Clinical Sciences, Karolinska Institutet, Danderyd University Hospital, Stockholm, 182 88, Sweden
| | - Piotr Harbut
- Department of Anaesthesia and Intensive Care, Institution for Clinical Sciences, Karolinska Institutet, Danderyd University Hospital, Stockholm, 182 88, Sweden
| |
Collapse
|
24
|
Initial experience with irreversible electroporation of liver tumours. Eur J Radiol Open 2019; 6:62-67. [PMID: 30723754 PMCID: PMC6351588 DOI: 10.1016/j.ejro.2019.01.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2018] [Revised: 01/14/2019] [Accepted: 01/17/2019] [Indexed: 12/18/2022] Open
Abstract
Introduction Thermal ablation of liver tumours is an established technique used in selected patients with relatively small tumours that can be ablated with margin. Thermal ablation methods are not advisable near larger bile ducts that are sensitive to thermal injury causing strictures and severe morbidity. Irreversible electroporation (IRE) has the possibility to treat these tumours without harming the bile tree. The method is relatively new and has been proven to be feasible and safe with promising oncological results. Methods 50 treatments were performed on 42 patients that were not resectable or treatable by thermal ablation (12 women and 30 men) with 59 tumours in total. 51% were colorectal cancer liver metastases (CRCLM) and 34% were hepatocellular carcinomas (HCC). 70% of the treatments were performed using stereotactic CT-guidance for needle placement. Results 81% of the treatments were performed with initial success. All patients with missed ablations were re-treated. Local recurrence rate at 3 months was 3% and 37% at one year. The complication rate was low with 2 patients having major complications (Clavien-Dindo grade 3b-5) and without 30-day mortality. Conclusion IRE is safe for treating tumours not suitable for thermal ablation with 63% of patients being without local recurrence after one year in a group of patients with tumours deemed unresectable. IRE has a role in the treatment of unresectable liver tumours close to heat-sensitive structures not suitable for thermal ablation. Level of Evidence: Level 4, Case Series.
Collapse
|
25
|
Cronin B, Dalia A, Nguyen QS, Slotto J, Elhassan A, Maus T, Essandoh MK. The Year in Electrophysiology: Selected Highlights From 2018. J Cardiothorac Vasc Anesth 2019; 33:1771-1777. [PMID: 30765206 DOI: 10.1053/j.jvca.2019.01.049] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2019] [Indexed: 01/20/2023]
Abstract
This article is the first in an annual series for the Journal of Cardiothoracic and Vascular Anesthesia. The authors thank the editor-in-chief, Dr. Kaplan, the associate editor-in-chief, Dr. Augoustides, and the editorial board for the opportunity to start this series, namely the research highlights of the year that pertain to electrophysiology in relation to cardiothoracic and vascular anesthesia. This first article focuses on esophageal thermal injury during radiofrequency ablation, perioperative management of patients presenting for ablation procedures, left atrial appendage occlusion devices, and, finally, heart failure diagnostic devices.
Collapse
Affiliation(s)
- Brett Cronin
- Department of Anesthesiology, University of California, San Diego, UCSD Medical Center, San Diego, CA.
| | - Adam Dalia
- Division of Cardiac Anesthesiology, Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital-Harvard Medical School, Boston, MA
| | | | - James Slotto
- University of California, San Diego, San Diego, CA
| | | | - Timothy Maus
- Department of Anesthesiology, University of California, San Diego, UCSD Medical Center, San Diego, CA
| | - Michael K Essandoh
- Department of Anesthesiology, The Ohio State University Medical Center, Columbus, OH
| |
Collapse
|
26
|
Fujii S, Zhou JR, Dhir A. Anesthesia for Cardiac Ablation. J Cardiothorac Vasc Anesth 2018; 32:1892-1910. [DOI: 10.1053/j.jvca.2017.12.039] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2017] [Indexed: 12/19/2022]
|
27
|
Galmén K, Freedman J, Toporek G, Goździk W, Harbut P. Clinical application of high frequency jet ventilation in stereotactic liver ablations - a methodological study. F1000Res 2018; 7:773. [PMID: 30271582 PMCID: PMC6113879 DOI: 10.12688/f1000research.14873.2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/05/2018] [Indexed: 01/08/2023] Open
Abstract
Background: Computer-assisted navigation during thermal ablation of liver tumours, may help to correct needle placement and improve ablation efficacy in percutaneous, laparoscopic and open interventions. The potential advantage of using high frequency jet-ventilation technique (HFJV) during the procedure is by minimising the amplitude of respiration-related upper-abdominal organs movements. The aim of this clinical methodological trial was to establish whether HFJV would give less ventilatory induced liver movements than conventional ventilation, during stereotactic navigated ablation of liver metastases under open surgery. Methods: Five consecutive patients scheduled for elective, open liver ablation under general propofol and remifentanil anaesthesia were included in the study protocol. During the stereotactic targeting of the tumours, HFJV was chosen for intraoperative lung ventilation. For tracking of liver movement, a rigid marker shield was placed on the liver surface and tracked with an optical position measurement system. A 4D position of the marker shield was measured for HFJV and conventional tidal volume lung ventilation (TV). At each time point the magnitude of liver displacement was calculated as an Euclidean distance between translational component of the marker shield's 3D position and previously estimated centroid of the translational motion. Results: The mean Euclidean liver displacement was 0.80 (0.10) mm for HFJV and 2,90 (1.03) mm for TV with maximum displacement going as far as 12 mm on standard ventilation (p=0.0001). Conclusion: HFJV is a valuable lung ventilation method for patients undergoing stereotactic surgical procedures in general anaesthesia when reduction of organ displacement is crucial.
Collapse
Affiliation(s)
- Karolina Galmén
- Department of Anaesthesiology and Intensive Therapy, Danderyd University Hospital, Stockholm, Sweden
| | - Jacob Freedman
- Department of Surgery and Urology, Danderyd University Hospital, Stockholm, Sweden
| | - Grzegorz Toporek
- ARTORG Center for Biomedical Engineering, University of Bern, Bern, Switzerland
| | - Waldemar Goździk
- Department of Anaesthesiology and Intensive Therapy, Wrocław Medical University, Wrocław, Poland
| | - Piotr Harbut
- Department of Anaesthesiology and Intensive Therapy, Danderyd University Hospital, Stockholm, Sweden
| |
Collapse
|
28
|
Galmén K, Freedman J, Toporek G, Goździk W, Harbut P. Clinical application of high frequency jet ventilation in stereotactic liver ablations - a methodological study. F1000Res 2018; 7:773. [PMID: 30271582 PMCID: PMC6113879 DOI: 10.12688/f1000research.14873.1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/14/2018] [Indexed: 09/29/2023] Open
Abstract
Background: Computer-assisted navigation during thermal ablation of liver tumours, may help to correct needle placement and improve ablation efficacy in percutaneous, laparoscopic and open interventions. The potential advantage of using high frequency jet-ventilation technique (HFJV) during the procedure is by minimising the amplitude of respiration-related upper-abdominal organs movements. The aim of this clinical methodological trial was to establish whether HFJV would give less ventilatory induced liver movements than conventional ventilation, during stereotactic navigated ablation of liver metastases under open surgery. Methods: Five consecutive patients scheduled for elective, open liver ablation under general propofol and remifentanil anaesthesia were included in the study protocol. During the stereotactic targeting of the tumours, HFJV was chosen for intraoperative lung ventilation. For tracking of liver movement, a rigid marker shield was placed on the liver surface and tracked with an optical position measurement system. A 4D position of the marker shield was measured for HFJV and conventional tidal volume lung ventilation (TV). At each time point the magnitude of liver displacement was calculated as an Euclidean distance between translational component of the marker shield's 3D position and previously estimated centroid of the translational motion. Results: The mean Euclidean liver displacement was 0.80 (0.10) mm for HFJV and 2,90 (1.03) mm for TV with maximum displacement going as far as 12 mm on standard ventilation (p=0.0001). Conclusion: HFJV is a valuable lung ventilation method for patients undergoing stereotactic surgical procedures in general anaesthesia when reduction of organ displacement is crucial.
Collapse
Affiliation(s)
- Karolina Galmén
- Department of Anaesthesiology and Intensive Therapy, Danderyd University Hospital, Stockholm, Sweden
| | - Jacob Freedman
- Department of Surgery and Urology, Danderyd University Hospital, Stockholm, Sweden
| | - Grzegorz Toporek
- ARTORG Center for Biomedical Engineering, University of Bern, Bern, Switzerland
| | - Waldemar Goździk
- Department of Anaesthesiology and Intensive Therapy, Wrocław Medical University, Wrocław, Poland
| | - Piotr Harbut
- Department of Anaesthesiology and Intensive Therapy, Danderyd University Hospital, Stockholm, Sweden
| |
Collapse
|