1
|
Levy MJ, Wend CM, Flemming WP, Lazieh A, Rosenblum AJ, Pineda CM, Wolfberg DM, Jenkins JL, Goolsby CA, Margolis AM. Bleeding Control Protections Within US Good Samaritan Laws. Prehosp Disaster Med 2024; 39:156-162. [PMID: 38572644 DOI: 10.1017/s1049023x24000268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2024]
Abstract
INTRODUCTION In the United States, all 50 states and the District of Columbia have Good Samaritan Laws (GSLs). Designed to encourage bystanders to aid at the scene of an emergency, GSLs generally limit the risk of civil tort liability if the care is rendered in good faith. Nation-wide, a leading cause of preventable death is uncontrolled external hemorrhage. Public bleeding control initiatives aim to train the public to recognize life-threatening external bleeding, perform life-sustaining interventions (including direct pressure, tourniquet application, and wound packing), and to promote access to bleeding control equipment to ensure a rapid response from bystanders. METHODS This study sought to identify the GSLs in each state and the District of Columbia to identify what type of responder is covered by the law (eg, all laypersons, only trained individuals, or only licensed health care providers) and if bleeding control is explicitly included or excluded in their Good Samaritan coverage. RESULTS Good Samaritan Laws providing civil liability qualified immunity were identified in all 50 states and the District of Columbia. One state, Oklahoma, specifically includes bleeding control in its GSLs. Six states - Connecticut, Illinois, Kansas, Kentucky, Michigan, and Missouri - have laws that define those covered under Good Samaritan immunity, generally limiting protection to individuals trained in a standard first aid or resuscitation course or health care clinicians. No state explicitly excludes bleeding control from their GSLs, and one state expressly includes it. CONCLUSION Nation-wide across the United States, most states have broad bystander coverage within GSLs for emergency medical conditions of all types, including bleeding emergencies, and no state explicitly excludes bleeding control interventions. Some states restrict coverage to those health care personnel or bystanders who have completed a specific training program. Opportunity exists for additional research into those states whose GSLs may not be inclusive of bleeding control interventions.
Collapse
Affiliation(s)
- Matthew J Levy
- Johns Hopkins School of Medicine, Baltimore, MarylandUSA
| | | | | | - Antoin Lazieh
- Rutgers New Jersey Medical School, Newark, New JerseyUSA
| | | | | | | | | | | | - Asa M Margolis
- Johns Hopkins School of Medicine, Baltimore, MarylandUSA
| |
Collapse
|
2
|
Salchner H, Isser M, Banyai L, Schachner T, Wiedermann FJ, Lederer W. Arterial Occlusion Effectiveness of Space Blanket‒Improvised Tourniquets for the Remote Setting. Wilderness Environ Med 2023; 34:269-276. [PMID: 37100664 DOI: 10.1016/j.wem.2023.02.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 01/09/2023] [Accepted: 02/08/2023] [Indexed: 04/28/2023]
Abstract
INTRODUCTION Control of severe extremity hemorrhage by tourniquet can save lives. In remote areas or in mass casualty incidents with multiple severely bleeding victims, lack of conventional tourniquets may make it necessary to improvise tourniquets. METHODS Occlusion of the radial artery and delayed onset of capillary refill time resulting from windlass-type tourniquets were experimentally investigated by comparing a commercial tourniquet and a space blanket‒improvised tourniquet with a carabiner as a rod. This observational study was conducted on healthy volunteers in optimal application circumstances. RESULTS Operator-applied Combat Application Tourniquets were deployed more swiftly (27 s, 95% CI: 25.7-30.2 vs 94 s, 95% CI: 81.7-114.4) and achieved 100% complete radial occlusion compared with improvised tourniquets, as assessed by Doppler sonography (P<0.001). When space blanket‒improvised tourniquets were used, traces of radial perfusion persisted in 48% of the applications. In Combat Application Tourniquets, capillary refill times were significantly delayed (7 s, 95% CI: 6.0-8.2 vs 5 s, 95% CI: 3.9-6.3) compared with those when using improvised tourniquets (P=0.013). CONCLUSIONS Improvised tourniquets should be considered only in dire circumstances with uncontrolled extremity hemorrhage and when no commercial tourniquets are available. Complete arterial occlusion was achieved in only half of the applications using a space blanket‒improvised tourniquet when a carabiner was used as a windlass rod. The speed of application was inferior to that for Combat Application Tourniquets. Similar to Combat Action Tourniquets, the correct assembly and application of space blanket‒improvised tourniquets on upper and lower extremities have to be trained. TRIAL REGISTRATION ClinicalTrials.gov identifier: BASG No.: 13370800/15451670.
Collapse
Affiliation(s)
- Hannah Salchner
- Department of Anesthesiology and Critical Care Medicine, Medical University of Innsbruck, Innsbruck, Austria; Medical Division, Austrian Mountain Rescue Service-Tyrol, Telfs, Austria
| | - Markus Isser
- Medical Division, Austrian Mountain Rescue Service-Tyrol, Telfs, Austria
| | - Lukas Banyai
- Department of Anesthesiology and Critical Care Medicine, Medical University of Innsbruck, Innsbruck, Austria
| | - Thomas Schachner
- Department of Cardiac Surgery, Medical University of Innsbruck, Innsbruck, Austria
| | - Franz J Wiedermann
- Department of Anesthesiology and Critical Care Medicine, Medical University of Innsbruck, Innsbruck, Austria
| | - Wolfgang Lederer
- Department of Anesthesiology and Critical Care Medicine, Medical University of Innsbruck, Innsbruck, Austria.
| |
Collapse
|
3
|
Levy MJ, Krohmer J, Goralnick E, Charlton N, Nemeth I, Jacobs L, Goolsby CA. A framework for the design and implementation of Stop the Bleed and public access trauma equipment programs. J Am Coll Emerg Physicians Open 2022; 3:e12833. [PMID: 36311340 PMCID: PMC9611563 DOI: 10.1002/emp2.12833] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 08/06/2022] [Accepted: 09/27/2022] [Indexed: 12/03/2022] Open
Abstract
Traumatic injuries remain the leading cause of death for those under the age of 44 years old. Nearly a third of those who die from trauma do so from bleeding. Reducing death from severe bleeding requires training in the recognition and treatment of life-threatening bleeding, as well as programs to ensure immediate access to bleeding control resources. The Stop the Bleed (STB) initiative seeks to educate and empower people to be immediate responders and provide control of life-threatening bleeding until emergency medical services arrive. Well-planned and implemented STB programs will help ensure program effectiveness, minimize variability, and provide long-term sustainment. Comprehensive STB programs foster consistency, promote access to bleeding control education, contain a framework to guide the acquisition and placement of equipment, and promote the use of these resources at the time of a bleeding emergency. We leveraged the expertise and experience of the Stop the Bleed Education Consortium to create a resource document to help inform and guide STB program developers and implementers on the key areas for consideration when crafting strategy. These areas include (1) equipment selection, (2) logistics and kit placement, (3) educational program accessibility and implementation, and (4) program oversight, facilitation, and administration.
Collapse
Affiliation(s)
- Matthew J. Levy
- Department of Emergency MedicineJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- National Center for Disaster Medicine and Public HealthBethesdaMarylandUSA
| | - Jon Krohmer
- Department of Emergency MedicineMichigan State UniversityGrand RapidsMichiganUSA
| | - Eric Goralnick
- Department of Emergency MedicineHarvard Medical SchoolBostonMassachusettsUSA
| | - Nathan Charlton
- Department of Emergency MedicineUniversity of Virginia School of MedicineCharlottesvilleVirginiaUSA
| | - Ira Nemeth
- Department of Emergency MedicineUniversity of Massachusetts Medical SchoolWorcesterMassachusettsUSA
| | - Lenworth Jacobs
- Hartford Health CareAcademic Affairs, Hartford HospitalHartfordConnecticutUSA
| | - Craig A. Goolsby
- Department of Emergency Medicine, Harbor‐UCLA Medical CenterDavid Geffen School of Medicine at UCLALos AngelesCaliforniaUSA
| |
Collapse
|
4
|
Dayal S, Portela R, Taylor S, Byquist BR, Piner A, Adams J, March J. Measuring the Effect of Audio Instructions on the Time and Effectiveness of Tourniquet Application by Laypeople. PREHOSP EMERG CARE 2022:1-5. [PMID: 35500205 DOI: 10.1080/10903127.2022.2072551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Objective: The "Stop the Bleed" campaign was created to educate laypeople about bleeding control and make bleeding control kits available in public locations. Unfortunately, previous research has indicated that up to half of all laypeople cannot effectively apply a tourniquet. The purpose of this study was to determine if laypeople could apply tourniquets more effectively with just-in-time training using combined audio-written instructions versus written-only instructions.Methods: We conducted a prospective randomized study comparing the application of a tourniquet using a simulated bleeding arm. Participants were laypeople 18 years and older and excluded those with any previous tourniquet experience or training. Participants were randomized to just-in-time training using either audio-written or written-only instructions. Time in seconds to tourniquet application and the effectiveness of the tourniquet application was recorded. Effective application was defined as stopping the flow or significantly slowing the flow to a slow drip. Ineffective tourniquet placement was defined as not significantly changing the flow. Statistical analysis was performed using Fisher's exact, t-test, and linear regression.Results: Eighty-two participants were included; 40 were in the audio-written instructions group, and 58.5% were male. The audio-written group's effective application rate was 92.5% and that of the written-only group was 76.2%. A significantly higher rate of ineffective tourniquet application was noted for the written-only group, (23.8%), versus the audio-written group (7.5%), p=.04. Regardless of the type of instructions used, time to effective application of the tourniquet decreased as participant age increased (p = 0.02, 95%CI (-1.24, -0.13). There was no relationship between age and effective tourniquet application (p = 0.06). Time for tourniquet placement was not different between the audio-written (mean 100.4 seconds) and written-only (mean 106.1 seconds) groups (p = 0.58).Conclusion: This study suggests that combined audio-written instructions decrease the rate of ineffective tourniquet application by laypeople compared with written-only instructions. Further studies are needed to assess if audio instructions and just-in-time training can further maximize effective tourniquet application.
Collapse
|
5
|
Nichols R, Horstman J. Recommendations for Improving Stop the Bleed: A Systematic Review. Mil Med 2022; 187:e1338-e1345. [PMID: 35084491 DOI: 10.1093/milmed/usac019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 12/28/2021] [Accepted: 01/24/2022] [Indexed: 11/14/2022] Open
Abstract
INTRODUCTION In response to mass casualty events, The Hartford Consensus brought together subject matter experts across multiple disciplines in health care and public safety to create guidelines and publications intended to improve survivability in active shooter events. Among the recommendations was the earlier recognition and treatment application of life-threatening hemorrhage control. These recommendations culminated in efforts to create the Stop the Bleed Campaign, which aims to empower the layperson to render aid in a life-threatening bleeding emergency. As of February 2020, the program has held over 86,000 courses, trained over 1.4 million attendees, and over 77,000 instructors since its inception. In addition to spreading within the United States, American College of Surgeons (ACS) Stop the Bleed (StB) classes have been held in 118 different countries. This systematic narrative review aims to answer the following research question: What does the ACS StB Initiative do well, and where can it improve? MATERIALS AND METHODS The following search terms were utilized: "Stop the Bleed," "American College of Surgeons," "bleeding control," "first-aid," tourniquet, "wound pack," "direct pressure" hemorrhage, and bystander. The inclusion criteria were that the article needed to speak to the program or some aspect of bystander first aid, the article needed to be in a civilian setting, the article needed to be more than a case study or overview, and the first aid tools needed to be in the StB curriculum. 4 databases were searched, which produced 138 articles for screening. One hundred four full-text articles were able to be retrieved, and 56 articles were determined to meet the inclusion criteria once the full text was reviewed. RESULTS Fifty-six articles were included in the final review and were placed into the following categories: Needs Within the Community, Confidence and Knowledge, Training Modalities, Barriers and Gaps in Training, Instructor Selection, Skill Retention, and Patient Outcomes. The articles were then organized into each outcome for synthesis and reporting of the results. The program overwhelmingly improves short-term confidence, but gaps in skill retention, data collection on patient outcomes, and settings that would benefit were identified. CONCLUSION StB is an effective tool in building confidence in laypersons, which is its biggest strength. A review of the literature shows several areas where the curriculum and materials could be better developed. Research can also be further refined to better quantify the program's impact.
Collapse
Affiliation(s)
- Ryoma Nichols
- Elson S. Floyd College of Medicine, Washington State University, Spokane, WA 99202-2131, USA
| | - Jordan Horstman
- Kansas City University School of Osteopathic Medicine, Kansas City University, Kansas City, MO 64106, USA
| |
Collapse
|
6
|
Viola L, Lagazzi E, Ballardini G, Drogo A, Bonetti M, Marrone E, Chirico M, Ricci S. Design of a system to detect the force applied by tourniquets in a manikin's limb. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:5019-5022. [PMID: 34892334 DOI: 10.1109/embc46164.2021.9631020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Massive hemorrhage remains the number one cause of preventable death in trauma worldwide. However, immediate intervention by a bystander can significantly improve the survival of the injured person. In this context, the tourniquets represent the most quick and effective devices for stopping arterial and venous blood flow. The aim of this study was to implement a system to detect the force applied by a tourniquet on a simulated limb, without blood flow. The system we designed is characterized by four low-cost force sensing resistors placed on each lower limb of a manikin, below the groin. Tests on 21 tourniquets, revealed that our system is able to detect the force applied for 60 minutes, also discriminating between turns. Hence, this system can be used to compare the performance of different types of devices, but also to assess proper tourniquet placement in trainees and trauma care providers, thus making it a versatile low-cost device.
Collapse
|
7
|
Matinrad N, Reuter-Oppermann M. A review on initiatives for the management of daily medical emergencies prior to the arrival of emergency medical services. CENTRAL EUROPEAN JOURNAL OF OPERATIONS RESEARCH 2021; 30:251-302. [PMID: 34566490 PMCID: PMC8449697 DOI: 10.1007/s10100-021-00769-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 07/28/2021] [Indexed: 05/31/2023]
Abstract
Emergency services worldwide face increasing cost pressure that potentially limits their existing resources. In many countries, emergency services also face the issues of staff shortage-creating extra challenges and constraints, especially during crisis times such as the COVID-19 pandemic-as well as long distances to sparsely populated areas resulting in longer response times. To overcome these issues and potentially reduce consequences of daily (medical) emergencies, several countries, such as Sweden, Germany, and the Netherlands, have started initiatives using new types of human resources as well as equipment, which have not been part of the existing emergency systems before. These resources are employed in response to medical emergency cases if they can arrive earlier than emergency medical services (EMS). A good number of studies have investigated the use of these new types of resources in EMS systems, from medical, technical, and logistical perspectives as their study domains. Several review papers in the literature exist that focus on one or several of these new types of resources. However, to the best of our knowledge, no review paper that comprehensively considers all new types of resources in emergency medical response systems exists. We try to fill this gap by presenting a broad literature review of the studies focused on the different new types of resources, which are used prior to the arrival of EMS. Our objective is to present an application-based and methodological overview of these papers, to provide insights to this important field and to bring it to the attention of researchers as well as emergency managers and administrators.
Collapse
Affiliation(s)
- Niki Matinrad
- Department of Science and Technology, Linköping University, Norrköping, 60174 Sweden
| | - Melanie Reuter-Oppermann
- Information Systems - Software and Digital Business Group, Technical University of Darmstadt, 64289 Darmstadt, Germany
| |
Collapse
|
8
|
Treager C, Lopachin T, Mandichak S, Kinney B, Bohan M, Boboc M, Go C, Friedrich E, Stuart S. A comparison of efficacy, efficiency, and durability in novel tourniquet designs. J Trauma Acute Care Surg 2021; 91:S139-S145. [PMID: 33797479 DOI: 10.1097/ta.0000000000003216] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Exsanguination due to extremity hemorrhage is a major cause of preventable traumatic deaths. Extremity tourniquet use has been shown to be safe and improve survival. The purpose of this study was to compare the efficacy, efficiency, and durability of the Generation 7 Combat Application Tourniquet (CAT; North American Rescue, Greer, SC), the Tactical Mechanical Tourniquet (TMT; Combat Medical Systems, Harrisburg, NC), and the SOF Tactical Tourniquet-Wide (SOFTT-W; Tactical Medical Solutions, Anderson, SC). METHODS This study was a three-phase randomized, cross-over trial. In successive trials, subjects were timed during the application of each tourniquet to the upper and lower extremity. Following successful lower extremity application, subjects low crawled 25 ft and then were dragged 25 ft, after which effectiveness was reassessed, as defined by the cessation of distal pulses by Doppler ultrasound. RESULTS In arm application, both the CAT and TMT had significantly less failure rates than the SOFTT-W (5.56%, 19.44%, 58.33%), with the CAT being the fastest tourniquet when compared with TMT and SOFTT-W (37.8 seconds, 65.01 seconds, 63.07 seconds). In leg application, the CAT had significantly less rates of failure when compared with the SOFTT-W, but there was no other significant difference between the tourniquets (27.78%, 44.44%, 61.11%). In addition, the CAT was significantly faster than both the TMT and SOFTT-W when applied to the leg (8.33 seconds, 40.96 seconds, 34.5 seconds). There was no significant difference in tourniquet failure rates between the three tourniquets after subject maneuvers in phase 3 (34.29%, 42.86%, 45.45%). DISCUSSION The CAT is as effective as the TMT and significantly more effective than the SOFTT-W. In addition, the CAT demonstrated shorter application times than either the TMT or SOFTT-W. However, there was no significant difference between the three tourniquets in their ability to maintain pulselessness after subject maneuvers. LEVEL OF EVIDENCE Care management, level II.
Collapse
Affiliation(s)
- Christopher Treager
- From the Department of Emergency Medicine (C.T., T.L., S.M., S.S.), Naval Medical Readiness Training Command, Portsmouth; Combat Trauma Research Group (C.T., T.L., S.M., M. Bohan, M. Boboc, E.F., S.S.), Naval Medical Readiness Training Command, General Dynamics Information Technology, Fairfax, Virginia; Department of Emergency Medicine (B.K.), Naval Medical Readiness Training Command, Guam; and Eastern Virginia Medical School (C.G.), Norfolk, Virginia
| | | | | | | | | | | | | | | | | |
Collapse
|
9
|
El Bashtaly A, Khalil E, Méthot F, Ledoux-Hutchinson L, Franc JM, Homier V. Tourniquet application by schoolchildren-a randomized crossover study of three commercially available models. J Trauma Acute Care Surg 2021; 90:666-672. [PMID: 33405474 DOI: 10.1097/ta.0000000000003055] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Life-threatening hemorrhage is a major cause of preventable mortality in trauma. Studies have demonstrated the effectiveness and safety of commercial tourniquets when used by adult civilians. However, there are no data about tourniquet application by children.This study's goal is to determine which of three commercially available tourniquets is most effective when used by children. METHODS A randomized crossover study was conducted in four elementary schools in Montreal to compare three commercially available tourniquets. The study population is primary school children aged 10 to 12 years (5th-6th grade). A total of 181 students were invited to participate; 96 obtained parental approval and were recruited. Participants underwent a short 7-minute video training on the use of three commercial tourniquets and were subsequently given a 2-minute practice period. Students were evaluated on their ability to successfully apply the tourniquet and the time to complete application. After applying all three tourniquets, the students selected their favorite model. The primary outcome is the proportion of successful applications per tourniquet model. Secondary outcomes include time to successful application for each tourniquet model and tourniquet model preference. RESULTS The mechanical advantage tourniquet (MAT) outperformed the combat application tourniquet (CAT) and the stretch wrap and tuck tourniquet (SWATT) in terms of success rate (MAT, 67%; CAT, 44%; SWATT, 24%; p < 0.0001), time to application (MAT, 57 seconds; CAT, 80 seconds; SWATT, 90 seconds; p < 0.0001), and preference (MAT, 64%; CAT, 30%; SWATT, 6%; p < 0.0001). CONCLUSION In this study, the MAT performs better in terms of success rate, time to application, and preference when used by school-aged children. This study can be helpful when facilities are purchasing tourniquets for use by students.
Collapse
Affiliation(s)
- Alaa El Bashtaly
- From the Faculty of Medicine (A.E.B., F.M., L.L.-H.), Université de Montreal; Pediatric Emergency Medicine (E.K.), Montreal Children's Hospital, Montreal, Quebec; Faculty of Medicine (J.M.F.), University of Alberta, Edmonton, Alberta; and Adult Emergency Medicine (V.H.), McGill University Health Centre, Montreal, Quebec, Canada
| | | | | | | | | | | |
Collapse
|