La Rosa GRM, Leotta ML, Canova FS, Romeo VR, Cervino G, Generali L, Pedullà E. Cyclic fatigue resistance of different nickel-titanium instruments in single and double curvature at room and body temperatures: A laboratory study. AUST ENDOD J 2023; 49:592-598. [PMID: 37592880 DOI: 10.1111/aej.12789] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Accepted: 08/07/2023] [Indexed: 08/19/2023]
Abstract
The aim of this study was to compare the cyclic fatigue resistance of nickel-titanium instruments inside single and double-curved canals at different temperatures. 160 HyFlex EDM #20.05 (HEDM), VDW.ROTATE #20.05 and #25.06, Mtwo #25.06 were randomised (n = 10) for the dynamic cyclic fatigue tests according to the curvature (i.e. single and double) at 20° ± 1°C and 35° ± 1°C. The number of cycles to fracture (NCF) was analysed by two-way ANOVA with p < 0.05. Fatigue resistance of all instruments significantly decreased at body temperature in single and double curvatures, except for HEDM in double curvature. The NCF was significantly lower in double curvature than single at both temperatures for all files, except for VDW.ROTATE #20.05 at 35° ± 1°C. Within the study limitations, temperature significantly impaired cyclic fatigue resistance of all files except HEDM #20.05 in double curvature. Similarly, double curvature had a detrimental effect on cyclic fatigue resistance of all files except for VDW.ROTATE #20.05 at body temperature.
Collapse
Affiliation(s)
- Giusy Rita Maria La Rosa
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Maria Laura Leotta
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Francesco Saverio Canova
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Virginia Rosy Romeo
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Gabriele Cervino
- Department of Biomedical and Dental Sciences and Morphological and Functional Imaging, Messina University, Messina, Italy
| | - Luigi Generali
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Transplant Surgery, Oncology and Regenerative Medicine Relevance (CHIMOMO), University of Modena and Reggio Emilia, Modena, Italy
| | - Eugenio Pedullà
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| |
Collapse
|
2
|
Hiran-Us S, Morakul S. Effect of Temperatures on Cyclic Fatigue Resistance of 3 Different Ni-Ti Alloy Files. Int Dent J 2023; 73:904-909. [PMID: 37423864 PMCID: PMC10658440 DOI: 10.1016/j.identj.2023.06.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2023] [Revised: 05/24/2023] [Accepted: 06/20/2023] [Indexed: 07/11/2023] Open
Abstract
OBJECTIVE The aim of this study was to investigate and compare the effect of temperature on the cyclic fatigue resistance of conventional (ProTaper Universal [PTU]), Gold-Wire (ProTaper Gold [PTG]), and Fire-Wire (EdgeTaper Platinum [ETP]) nickel-titanium alloy files. METHOD Twenty files from each system were tested for cyclic fatigue resistance in an artificial canal model. The experiments were performed at room temperature and body temperature in controlled temperature water. Magnified videos were recorded using a dental operating microscope integrated camera during testing to detect file fracture. The number of cycles to failure (NCF) was calculated. The type of failure was investigated macroscopically and microscopically with a dental operating microscope and scanning electron microscope, respectively. RESULT The NCF at room temperature was significantly higher compared with body temperature in each system (P < .001). Compared at the same temperature, the ETP group demonstrated the highest NCF, followed by the PTG and PTU groups (P < .001). All files demonstrated cyclic fatigue failure macroscopically and microscopically. CONCLUSIONS The 3 alloy files were affected by temperature. The cyclic fatigue resistance was reduced at the higher temperature and increased at the lower temperature. If the files are geometrically identical, files made of Fire-Wire are preferred compared with Gold-Wire and conventional nickel-titanium alloys based on cyclic fatigue resistance.
Collapse
Affiliation(s)
- Sirawut Hiran-Us
- Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
| | - Sarita Morakul
- Composite Structures Research Unit, Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
3
|
Al Omari TMN, La Rosa GRM, Albanna RHI, Tabnjh A, Papale F, Pedullà E. The effect of different kinematics on apical debris extrusion with a single-file system. Odontology 2023; 111:910-915. [PMID: 36917401 PMCID: PMC10492679 DOI: 10.1007/s10266-023-00802-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 02/27/2023] [Indexed: 03/16/2023]
Abstract
To compare the amount of extruded debris caused by different motions using a single-file system. Fifty mandibular first molar teeth were randomized into 5 groups (n = 10) according to the motion tested: Optimize Torque Reverse (OTR), TF Adaptive Motion (TFA), continuous rotation (CR), reciprocation motion (+ 150°, -30°) (REC), and Jeni motion (Jeni). One Curve single file 25/06 (Micro-Mega, Besançon, France) was used in all experimental groups. The root canals were irrigated with 2.5% NaOCl, and the extruded debris were collected at pre-weighted glass vials. The glass vials were kept inside an incubator for one week at 70 °C to dry out the irrigating solution. The extruded debris was quantified by subtracting the pre-instrumentation from the post-instrumentation weight of the glass vials. The time required for each instrumentation procedure was digitally recorded. All data were analyzed statistically with one way ANOVA and post hoc Tukey test (P < 0.05). All the motions extruded apically debris with Jeni mode caused significantly less debris extrusion than TFA, REC, and CR (P < 0.05) while no significant difference emerged with OTR. Preparation time was not significantly different in all groups. Within the limits of the present study, all the kinematics produced apically debris extrusion, with Jeni reporting a similar amount of debris compared with OTR and significantly less than TFA, REC, and CR. Preparation time was similar among the tested kinematics.
Collapse
Affiliation(s)
- Taher M N Al Omari
- Department of Conservative Dentistry, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan
| | - Giusy Rita Maria La Rosa
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy.
| | - Rami Haitham Issa Albanna
- Department of Conservative Dentistry, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan
| | - Abedelmalek Tabnjh
- Department of Applied Dental Science, Faculty of Applied Medical Science, Jordan University of Science and Technology, Irbid, Jordan
| | - Flavia Papale
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Eugenio Pedullà
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| |
Collapse
|
4
|
Ramadan F, AbuMostafa A, Alharith D. Evaluation of cyclic fatigue and bending test for different Nickle-Titanium files. PLoS One 2023; 18:e0290744. [PMID: 37624849 PMCID: PMC10456180 DOI: 10.1371/journal.pone.0290744] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 08/14/2023] [Indexed: 08/27/2023] Open
Abstract
AIM To compare cyclic fatigue resistance and bending for three different nickel-titanium (NiTi) rotary files. MATERIALS AND METHODS A sample of 90 NiTi instruments size (25.06) was divided into three groups with 30 files in each: Race Evo files (FKG Dentaire, Switzerland); Tia Tornado Blue files (TiaDent Inc., Texas- USA); One Curve files (Micro-Mega, France). Then each group was subdivided into two groups with 15 files in each; a bending test was performed for one group, and a dynamic cyclic fatigue test at body temperature was performed for the other group. Files fractured by cyclic fatigue were randomly picked from all tested groups for Scanning Electron Microscopy (SEM) (Jeol, Tokyo, Japan). In addition, the test included measuring the broken part of the files tested using (Electronic Micrometre Calliper with LCD Screen, Inch and Millimetre Conversion, Adoric- Taiwan). Data were statistically analyzed using a one-way ANOVA with Tukey-HSD post hoc test. RESULTS It was found that maximum load [gf] was less (meaning more flexible) in the group of Tia Tornado Blue with a statistically significant difference in comparison with Race Evo and One Curve. The number of cycles to fracture (NCF) in the Race Evo group was significantly higher than the groups of One Curve and Tia Tornado Blue. CONCLUSIONS Within the limitation of the study, it could be concluded that Race Evo files were more resistant to cyclic fatigue fracture and Tia Tornado Blue files were more flexible compared to the other tested files.
Collapse
Affiliation(s)
- Farah Ramadan
- Department of Restorative Dentistry, Riyadh Elm University, College of Dentistry, Riyadh, Saudi Arabia
| | - Ammar AbuMostafa
- Department of Restorative Dentistry, Riyadh Elm University, College of Dentistry, Riyadh, Saudi Arabia
| | - Dalia Alharith
- Department of Restorative Dentistry, Riyadh Elm University, College of Dentistry, Riyadh, Saudi Arabia
| |
Collapse
|
5
|
El Abed R, Al Raeesi D, Alshehhi A, Alkhatib Z, Khamis AH, Jamal M, Kim HC. Effect from Autoclave Sterilization and Usage on the Fracture Resistance of Heat-Treated Nickel-Titanium Rotary Files. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2261. [PMID: 36984141 PMCID: PMC10056662 DOI: 10.3390/ma16062261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 03/03/2023] [Accepted: 03/08/2023] [Indexed: 06/18/2023]
Abstract
This study aimed to assess the effect of mechanical loading and heating on the cyclic fatigue and torsional fracture resistances of heat-treated nickel-titanium files after usage and autoclaving. Sixty files (One Curve) were tested for cyclic fatigue and torsional fracture resistances using customized devices. The files were divided into three groups according to the test conditions (n = 10); new (group-N), used for simulated canal shaping (group-U), and sterilized after use (group-S). For cyclic fatigue resistances, the files were freely rotated in a curved metal canal under body temperature; the time elapsed to fracture was recorded and the numbers of cycles to fracture (NCF) were calculated. For the torsional resistances, the file tip was fixed and rotated until the file fractured. The maximum torsional load and distortion angle were recorded. The toughness was calculated. Fracture fragments were examined with a scanning electron microscope. Data were analyzed using a one-way analysis of variance and Tukey's post hoc test at the significance level of 95%. Group-U showed significantly higher NCF than group-S (p < 0.05). However, there was no significant differences between groups-N and -S in the NCF (p > 0.05). Group-N showed a significantly bigger distortional angle and higher torsional toughness than groups-U and -S, but the ultimate torsional strength did not have significant difference between the groups. Under the limitation of this study, autoclave sterilization after single-usage did not improve the fracture resistance of heat-treated One Curve nickel-titanium files.
Collapse
Affiliation(s)
- Rashid El Abed
- Endodontic Department, Hamdan Bin Mohammed College of Dental Medicine, Mohammed Bin Rashid University of Medicine and Health Sciences, Dubai 505055, United Arab Emirates
| | - Dana Al Raeesi
- Endodontic Department, Emirates Health Services Establishment, Dubai, United Arab Emirates
| | - Aisha Alshehhi
- Endodontic Department, Hamdan Bin Mohammed College of Dental Medicine, Mohammed Bin Rashid University of Medicine and Health Sciences, Dubai 505055, United Arab Emirates
| | - Zuhair Alkhatib
- Endodontic Department, Hamdan Bin Mohammed College of Dental Medicine, Mohammed Bin Rashid University of Medicine and Health Sciences, Dubai 505055, United Arab Emirates
- Emirates Endodontic Society, Dubai, United Arab Emirates
| | - Amar H. Khamis
- Biostatistics Department, Hamdan Bin Mohammed College of Dental Medicine, Mohammed Bin Rashid University of Medicine and Health Sciences, Dubai 505055, United Arab Emirates
| | - Mohamed Jamal
- Endodontic Department, Hamdan Bin Mohammed College of Dental Medicine, Mohammed Bin Rashid University of Medicine and Health Sciences, Dubai 505055, United Arab Emirates
| | - Hyeon-Cheol Kim
- Department of Conservative Dentistry, School of Dentistry, Dental Research Institute, Pusan National University, Yangsan 50612, Republic of Korea
- Dental and Life Science Institute, Pusan National University, Yangsan 50612, Republic of Korea
| |
Collapse
|
6
|
Pedullà E, Kharouf N, Caruso S, La Rosa GRM, Jmal H, Haikel Y, Mancino D. Torsional, Static and Dynamic Cyclic Fatigue Resistance of Reciprocating and Continuous Rotating NiTi Instruments. J Endod 2022; 48:1421-1427. [PMID: 35987386 DOI: 10.1016/j.joen.2022.08.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 07/14/2022] [Accepted: 08/10/2022] [Indexed: 11/17/2022]
Abstract
INTRODUCTION To evaluate torsional, dynamic and static cyclic fatigue resistance of the reciprocating One Reci (OR, Micromega, Besançon, France), WaveOne Gold (WOG, Dentsply Maillefer, Ballaigues, Switzerland), rotary One Curve (OC, MicroMega, Besançon, France) and ProTaper Next X2 (PTN X2, Dentsply Sirona, Ballaigues, Switzerland) instruments. METHODS A total of 120 NiTi instruments (n = 30) OR, WOG, OC and PTN X2 were used. Torque and rotation angle until failure under static torsion loading were measured according to the ISO 3630-1. Static and dynamic fatigue resistance was measured as the time to fracture (TTF) in an artificial stainless-steel canal with a 60° angle and 5-mm radius of curvature at intracanal temperature. The results were analyzed with one-way ANOVA and post-hoc Tukey tests. The alpha-type error was set at 5%. Fracture instruments from torsion and fatigue tests were examined with scanning electron microscope. RESULTS The OR showed higher static fatigue resistance and rotation angle at fracture than the WOG, OC and PTN X2 (P < .05). The WOG exhibited higher torsional resistance than the others (P < .05). Dynamic cyclic fatigue resistance tests had highest TTF than static for the PTN X2 and the WOG groups (P < .05). In the dynamic tests, the OR and WOG showed higher TTF than the OC and PTN X2 (P < .05). CONCLUSIONS Under these experimental condition, One Reci exhibited suitable mechanical properties with the highest cyclic fatigue resistance and angle of rotation among the tested instruments.
Collapse
Affiliation(s)
- Eugenio Pedullà
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy.
| | - Naji Kharouf
- Department of Bioengineering and Biomaterials, INSERM (French National Institute of Health and Medical Research) 1121, University of Strasbourg, Strasbourg, France; Department of Endodontics, Faculty of Dental Medicine, University of Strasbourg, Strasbourg, France
| | - Simone Caruso
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Giusy Rita Maria La Rosa
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Hamdi Jmal
- ICube Laboratory, UMR 7357 CNRS, Mechanics Department, University of Strasbourg, Strasbourg, France
| | - Youssef Haikel
- Department of Bioengineering and Biomaterials, INSERM (French National Institute of Health and Medical Research) 1121, University of Strasbourg, Strasbourg, France; Department of Endodontics, Faculty of Dental Medicine, University of Strasbourg, Strasbourg, France
| | - Davide Mancino
- Department of Bioengineering and Biomaterials, INSERM (French National Institute of Health and Medical Research) 1121, University of Strasbourg, Strasbourg, France; Department of Endodontics, Faculty of Dental Medicine, University of Strasbourg, Strasbourg, France
| |
Collapse
|
7
|
Seracchiani M, Reda R, Zanza A, D'Angelo M, Russo P, Luca T. Mechanical performance and Metallurgical Characteristic of Five Different Single-File Reciprocating Instruments: a Comparative in Vitro and Laboratory Study. J Endod 2022; 48:1073-1080. [PMID: 35667568 DOI: 10.1016/j.joen.2022.05.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 04/16/2022] [Accepted: 05/26/2022] [Indexed: 11/18/2022]
Abstract
INTRODUCTION Since there are no data regarding an instrument recently introduced on the market (OneRECI), the aim of the study was to assess its mechanical and metallurgical properties comparing them with those of widespread reciprocating instruments such as Reciproc, Reciproc Blue, EdgeOne Fire and WaveOne Gold. METHODS A total of 65 NiTi files from five different reciprocating systems (OneRECI, Reciproc, Reciproc Blue, EdgeOne Fire and WaveOne Gold) were evaluated throughout a combined mechanical and metallurgical method. Mechanical performances of the selected file were examined subjecting each specimen to cyclic fatigue, torsional and bending resistance tests, whilst their metallurgical properties were assessed analyzing the nickel-titanium alloy composition and the phase transformation temperatures respectively through an energy-dispersive X-ray spectroscopy (EDX) and a differential scanning calorimetry (DSC). One-way ANOVA and post hoc Tukey's was performed with significance level set to a 95% confidence level. RESULTS The EDX showed a similar alloy composition for all of the tested files, with nickel percentage of about 52-53% and a corresponding percentage of titanium of 47-48%, whilst the DSC analysis, although evidenced martensitic characteristics for all files, showed differences in terms of phase transformation temperatures. Overall, OneRECI showed the best mechanical performances in terms of cyclic fatigue and torsional resistance (respectively of 32.95 ± 2.33 s and 0.76 ± 0.03 Ncm) and flexibility (48.4 ± 4.1 g), with statistically significant differences for all tests (p<0.05). Reciproc files showed the worst flexibility and cyclic fatigue resistance, respectively of 157.2 ± 8.3 g and 9.27 ± 1.18 s, whilst the EdgeOne Fire showed the lowest torsional resistance (0.39 ± 0.12 Ncm), whit statistically significant differences (p<0.05). CONCLUSIONS Within the limitation of this study, the recently introduced file OneRECI showed the best mechanical performance in comparison to the tested instruments, with an equiatomic composition of the NiTi alloy and a martensitic behavior.
Collapse
Affiliation(s)
- Marco Seracchiani
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Rodolfo Reda
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Alessio Zanza
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy.
| | - Maurilio D'Angelo
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Paola Russo
- Department of Chemical Engineering, Materials, Environment Dipartimento di Ingegneria Chimica Materiali Ambiente, La Sapienza University of Rome, Rome, Italy
| | - Testarelli Luca
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
8
|
Gouédard C, Pino L, Arbab-Chirani R, Arbab-Chirani S, Chevalier V. Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic files. Restor Dent Endod 2022; 47:e16. [PMID: 35692224 PMCID: PMC9160766 DOI: 10.5395/rde.2022.47.e16] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Revised: 10/18/2021] [Accepted: 11/03/2021] [Indexed: 11/11/2022] Open
Abstract
Objectives This study compared the cyclic fatigue resistance of One Curve (C wire) and F6 Skytaper (conventional austenite nickel-titanium [NiTi]), and 2 instruments with thermo-mechanically treated NiTi: Protaper Next X2 (M wire) and Hyflex CM (CM wire). Materials and Methods Ten new instruments of each group (size: 0.25 mm, 6% taper in the 3 mm tip region) were tested using a rotary bending machine with a 60° curvature angle and a 5 mm curvature radius, at room temperature. The number of cycles until fracture was recorded. The length of the fractured instruments was measured. The fracture surface of each fragment was examined with a scanning electron microscope (SEM). The data were analyzed using one-way analysis of variance and the post hoc Tukey test. The significance level was set at 0.05. Results At 60°, One Curve, F6 Skytaper and Hyflex CM had significantly longer fatigue lives than Protaper Next X2 (p < 0.05). No statistically significant differences were found in the cyclic fatigue lives of One Curve, F6 Skytaper, and Hyflex CM (p > 0.05). SEM images of the fracture surfaces of the different instruments showed typical features of fatigue failure. Conclusions Within the conditions of this study, at 60° and with a 5 mm curvature radius, the cyclic fatigue life of One Curve was not significantly different from those of F6 Skytaper and Hyflex CM. The cyclic fatigue lives of these 3 instruments were statistically significantly longer than that of Protaper Next.
Collapse
Affiliation(s)
- Charlotte Gouédard
- Department of Pediatric Dentistry, Dental School-Hospital of Brest, France.,University of Bretagne Occidentale, Brest, France
| | - Laurent Pino
- Ecole Nationale d'Ingénieurs de Brest, Brest, France
| | - Reza Arbab-Chirani
- Department of Endodontics and Restorative Dentistry, Dental School-Hospital of Brest, University of Bretagne Occidentale, Brest, France.,Laboratory of Medical Information Processing, Brest, France
| | | | - Valérie Chevalier
- University of Bretagne Occidentale, Brest, France.,Ecole Nationale d'Ingénieurs de Brest, Brest, France
| |
Collapse
|
9
|
Altufayli MD, Salim B, Katbeh I, Merei R, Mamasaidova Z. Shaping Ability of Reciproc Blue Versus One Curve in Curved Canal: An In-Vitro Study. Cureus 2022; 14:e24387. [PMID: 35619838 PMCID: PMC9126444 DOI: 10.7759/cureus.24387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/22/2022] [Indexed: 11/25/2022] Open
Abstract
The introduction of nickel-titanium (NiTi) rotary instruments improved the root canal preparation of the narrow and curved root canals, especially after the introduction of thermomechanical treated (NiTi) alloys that have a high flexibility to prepare the curved canal reducing the common clinical complication, such as fracture, the change of the original shape of the root canal as a result of the change in the curvature of the curved root canal, the change of the working length which caused by the creation of the ledges, canal transporting and zipping especially in medium and highly curved canal. This study aimed to compare the shaping ability of two heat-treated nickel-titanium single file systems using reciprocation motion and rotary motion in curved canals. Materials and methods Thirty extracted human teeth with one curved root at 25 to 56 degrees were used, two NiTi single file systems were used to prepare the curved root canal in two groups: Reciproc R25 (Munich, Germany: VDW) group (n=15) and One Curve (Besancon, France: Micro-Mega) group (n=15). Curved root canal instrumentation outcomes were evaluated using cone-beam computed tomography (CBCT). Kruskal-Wallis with Bonferroni post hoc test was used to assess differences between working length, the angle and radius of curvature after instrumentation. Results There was a significant difference in angle and radius of curvature (-1.83° One Curve, -2.25° Reciproc blue and -0.18 mm One Curve, -0.19 mm Reciproc blue, respectively) (p<0.05) after instrumentation for both One Curve and Reciproc blue groups, and there was no significant difference in working length change (-0.16 mm One Curve, -0.32 mm Reciproc blue) after instrumentation of both One Curve and Reciproc blue groups (p>0.05). Conclusion The Reciproc blue single file system with reciprocation movement and One Curve with continuous movement cause a significant difference in curvature and radius of curved root canal affecting the original shape of the root canal with no significant difference in working length of the curved root canal.
Collapse
|
10
|
Pedullà E, La Rosa GRM, Romano G, Leanza G, Rapisarda S, Isola G, Ferlito S, Neelakantan P, Generali L. Influence of kinematics and incidence angles on the cutting efficiency of two single-file nickel-titanium rotary instruments. AUST ENDOD J 2022; 48:58-64. [PMID: 34258843 PMCID: PMC9290840 DOI: 10.1111/aej.12543] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2020] [Revised: 06/15/2021] [Accepted: 06/26/2021] [Indexed: 02/05/2023]
Abstract
To compare the cutting efficiency of F6 Sky Taper (F6ST) and One Curve (OC) with different kinematics and cutting inclinations. Cutting efficiency of 80 new F6ST and OC was tested at 90° and 70° inclination in relation to the sample, in continuous rotation and reciprocation, against standardised gypsum samples for 120 seconds using a customised device. Data expressed as weight loss and length of the sample cut were analysed using two-way analysis of variance and Tukey t-test (P<.05). F6ST showed significantly higher cutting efficiency in reciprocation, while OC in continuous rotation. Regardless of inclination, F6ST showed statistically higher values than OC in reciprocation, while OC exhibited higher cutting ability in continuous rotation. The 70° inclination significantly improved the cutting efficiency of both files. Reciprocation improved the cutting efficiency of F6ST while continuous rotation enhanced cutting ability of OC. An inclined insertion improved the cutting ability, independently from the movement.
Collapse
Affiliation(s)
- Eugenio Pedullà
- Department of General Surgery and Medical ‐ Surgical SpecialtiesUniversity of CataniaCataniaItaly
| | - Giusy Rita Maria La Rosa
- Department of General Surgery and Medical ‐ Surgical SpecialtiesUniversity of CataniaCataniaItaly
| | - Giuseppe Romano
- Department of General Surgery and Medical ‐ Surgical SpecialtiesUniversity of CataniaCataniaItaly
| | - Giuseppe Leanza
- Department of General Surgery and Medical ‐ Surgical SpecialtiesUniversity of CataniaCataniaItaly
| | - Silvia Rapisarda
- Department of General Surgery and Medical ‐ Surgical SpecialtiesUniversity of CataniaCataniaItaly
| | - Gaetano Isola
- Department of General Surgery and Medical ‐ Surgical SpecialtiesUniversity of CataniaCataniaItaly
| | - Sebastiano Ferlito
- Department of General Surgery and Medical ‐ Surgical SpecialtiesUniversity of CataniaCataniaItaly
| | - Prasanna Neelakantan
- Discipline of EndodontologyFaculty of DentistryThe University of Hong KongThe Prince Philip Dental HospitalHong Kong SARChina
| | - Luigi Generali
- Endodontic SectionDepartment of Surgery, MedicineDentistry and Morphological Sciences with Transplant Surgery, Oncology and Regenerative Medicine Relevance (CHIMOMO)School of DentistryUniversity of Modena and Reggio EmiliaModenaItaly
| |
Collapse
|
11
|
Sharma S, Savitha S, Kumar V, Chawla A, Vanamail P, Logani A. Effect of body temperature on the cyclic fatigue resistance of the nickel”titanium endodontic instruments: A systematic review and meta-analysis of in vitro studies. J Conserv Dent 2022; 25:338-346. [PMID: 36187856 PMCID: PMC9520645 DOI: 10.4103/jcd.jcd_55_22] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 04/18/2022] [Accepted: 05/03/2022] [Indexed: 11/27/2022] Open
Abstract
Aim: The aim of this systematic review was to compare the effect of body temperature (I) on the cyclic fatigue resistance (O) of nickel–titanium (NiTi) endodontic instruments (P) to that of room temperature (C). Methods: The study was registered in the PROSPERO database (CRD42020204286). A systematic search in PubMed, Scopus, Web of Science, Google Scholar, and OpenGrey was conducted in English until December 31, 2021. In vitro studies comparing the cyclic fatigue resistance of NiTi instruments at the body (35°C ± 2°C) and room temperature (20°C–25°C) were included. Eligible studies were evaluated for risk of bias and meta-analyzed to estimate the effects. Results: Twenty-one studies out of 347 met the criteria for inclusion. The meta-analysis included six studies (n = 215) with comparative study parameters. The overall effect sizes (5.49; 95% confidence interval [CI]: 4.04–6.93) were significantly different (P < 0.001), indicating that the mean values at room temperature were significantly (P < 0.001) higher. The effect sizes for full rotary motion (standardized mean difference [SMD]: 4.80; 95% CI: 3.04–6.56) and reciprocating motion (SMD: 6.37; 95% CI: 3.63–9.11) were not significantly different (P = 0.346). Heterogeneity was high (I2 = 94%). Sensitivity analysis revealed that the SMD values were not significantly different (P > 0.05) from the overall effect size, indicating that none of the studies had an effect on the overall effect size. Conclusions: Within the limitation of the study, the cyclic fatigue resistance of heat-treated NiTi endodontic files is significantly reduced at body temperature when compared to room temperature. Cyclic fatigue testing should be conducted at simulated body temperature.
Collapse
|
12
|
La Rosa GRM, Palermo C, Ferlito S, Isola G, Indelicato F, Pedullà E. Influence of surrounding temperature and angle of file access on cyclic fatigue resistance of two single file nickel-titanium instruments. AUST ENDOD J 2021; 47:260-264. [PMID: 33277785 DOI: 10.1111/aej.12473] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Accepted: 11/21/2020] [Indexed: 02/05/2023]
Abstract
The purpose of this study was to evaluate the influence of surrounding temperature and angle of file access on cyclic fatigue resistance of F6 SkyTaper (F6ST) and One Curve (OC). 120 new files #25.06 were tested at two insertion angles (0° and 20°) at room (20°C ± 1°C) and body (35°C ± 1°C) temperatures in a 16-mm stainless steel artificial canal (60° curvature and 5-mm radius), using a customised device. Cyclic fatigue resistance was expressed as time to fracture (TtF) in seconds. Data were analysed statistically (P < 0.05). All instruments exhibited lower TtF at 35°C (P < 0.05). An access of 20° did not significantly influence the TtF of tested instruments, independently from the temperature. OC exhibited higher TtF of F6ST at 20°C with a 20° inclination (P < 0.05). Under the present conditions, F6ST and OC showed a significant reduction of cyclic fatigue resistance at body temperature. A file inclined insertion did not affect the cyclic fatigue resistance of tested instruments at both temperatures.
Collapse
Affiliation(s)
- Giusy Rita Maria La Rosa
- Department of General Surgery and Medical - Surgical Specialties, University of Catania, Catania, Italy
| | - Carlotta Palermo
- Department of General Surgery and Medical - Surgical Specialties, University of Catania, Catania, Italy
| | - Sebastiano Ferlito
- Department of General Surgery and Medical - Surgical Specialties, University of Catania, Catania, Italy
| | - Gaetano Isola
- Department of General Surgery and Medical - Surgical Specialties, University of Catania, Catania, Italy
| | - Francesco Indelicato
- Department of General Surgery and Medical - Surgical Specialties, University of Catania, Catania, Italy
| | - Eugenio Pedullà
- Department of General Surgery and Medical - Surgical Specialties, University of Catania, Catania, Italy
| |
Collapse
|
13
|
La Rosa GRM, Shumakova V, Isola G, Indelicato F, Bugea C, Pedullà E. Evaluation of the Cyclic Fatigue of Two Single Files at Body and Room Temperature with Different Radii of Curvature. MATERIALS 2021; 14:ma14092256. [PMID: 33925573 PMCID: PMC8123902 DOI: 10.3390/ma14092256] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/21/2021] [Revised: 04/12/2021] [Accepted: 04/25/2021] [Indexed: 02/07/2023]
Abstract
Background: To compare the influence of different temperatures and curvature radii on the cyclic fatigue resistance of F6 SkyTaper (F6ST) and One Curve (OC) single file nickel-titanium rotary instruments. Methods: A total of 120 instruments of F6ST and OC #25.06 were evaluated in 5 mm and 3 mm curvature radii at two temperatures (20 °C ± 1 °C and 37 °C ± 1 °C) in 16 mm stainless steel artificial canals associated with a curvature of 60°. The cyclic fatigue of tested files was assessed by employing a customized testing apparatus and expressed as times to fracture (TtF). A statistical analysis was performed with the significance level set at 95%. Results: All instruments decreased their TtF at 37 °C except for OC in the 3 mm radius, in which no significant difference was detected between 20 °C and 37 °C. A 3 mm curvature radius negatively affected TtF of all tested instruments, except for F6ST at 20 °C. F6ST had higher TtF than OC in the 3 mm radius at 20 °C, with no significant difference between them in the other tested conditions. Conclusions: Under the limits of the present in vitro study, body temperature impaired cyclic fatigue resistance of all files, except for OC in the 3 mm curvature radius. All instruments exhibited lower times to fracture in the 3 mm radius, excluding F6ST at 20 °C.
Collapse
Affiliation(s)
- Giusy Rita Maria La Rosa
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Plebiscito 628, 95124 Catania, Italy; (V.S.); (G.I.); (F.I.); (E.P.)
- Correspondence:
| | - Valeria Shumakova
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Plebiscito 628, 95124 Catania, Italy; (V.S.); (G.I.); (F.I.); (E.P.)
| | - Gaetano Isola
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Plebiscito 628, 95124 Catania, Italy; (V.S.); (G.I.); (F.I.); (E.P.)
| | - Francesco Indelicato
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Plebiscito 628, 95124 Catania, Italy; (V.S.); (G.I.); (F.I.); (E.P.)
| | | | - Eugenio Pedullà
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Plebiscito 628, 95124 Catania, Italy; (V.S.); (G.I.); (F.I.); (E.P.)
| |
Collapse
|
14
|
Yalniz H, Koohnavard M, Oncu A, Celikten B, Orhan AI, Orhan K. Comparative evaluation of dentin volume removal and centralization of the root canal after shaping with the ProTaper Universal, ProTaper Gold, and One-Curve instruments using micro-CT. J Dent Res Dent Clin Dent Prospects 2021; 15:47-52. [PMID: 33927841 PMCID: PMC8058162 DOI: 10.34172/joddd.2021.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Accepted: 11/29/2020] [Indexed: 11/19/2022] Open
Abstract
Background. The main goal of our study was to assess the volume of dentin removed and transportation in root canals using ProTaper Universal (PTU), ProTaper Gold (PTG) and One-Curve (OC). Ni-Ti rotary instruments in extracted human teeth using by micro-CT. Methods: Thirty human upper 1st premolar teeth with two separate root canals and sturdy, mature root tips were used in the present study. Specimens were decoronated and root length was standardized for micro CT scanning before root canal preparation done. The teeth were randomly separated into three categories (n = 10) according to the rotary NiTi system used for canal instrumentation, i.e., PTU (Dentsply, Maillefer), PTG (Dentsply, Maillefer), and OC (Micro-Mega SA). After root canal preparation, samples were scanned again on micro-CT by the same scanning parameters. Surface area, canal volume, structure model index (SMI), percentage of uninstrumented area and transportation parameters were obtained for each sample before and after micro-CT analyse. Results: No significant differences between the PTG and PTU in terms of the total volume of removed dentin, surface area and percentage of uninstrumented areas were found. However, regarding to parameters above, OC showed a lower efficacy than PTG and PTU in coronal section. Regarding canal transportation, PTG and OC showed lower mean transportation values at all levels. Conclusion: This paper demonstrated the root canal shaping abilities of the PTU, PTG, and OC NiTi file systems. The PTG and OC systems were associated less canal transportation and a better ability to preserve dentinal walls than PTU. There was no significance different between all rotary file systems for SMI values however, PTU and PTG showed greater canal volume and surface area change than OC file systems in coronal section.
Collapse
Affiliation(s)
- Hatice Yalniz
- Bezmialem Vakif University, Faculty of Dentistry, Department of Endodontics, Istanbul, Turkey
| | - Mehrdad Koohnavard
- Ankara University, Faculty of Dentistry, Department of Endodontics, Ankara, Turkey
| | - Aysenur Oncu
- Ankara University, Faculty of Dentistry, Department of Endodontics, Ankara, Turkey
| | - Berkan Celikten
- Ankara University, Faculty of Dentistry, Department of Endodontics, Ankara, Turkey
| | - Ayse Isil Orhan
- Ankara Yildirim Beyazit University, Department of Pediatric Dentistry, Ankara, Turkey
| | - Kaan Orhan
- Ankara University, Faculty of Dentistry, Department of DentoMaxillofacial Radiology, Ankara, Turkey
| |
Collapse
|
15
|
Al-Nasrawi SJH, Ayad Jaber Z, Talib Al-Quraine N, Imhemed Aljdaimi A, Jabbar Abdul-Zahra Al-Hmedat S, Zidan S, Haider J. Impact of Peracetic Acid on the Dynamic Cyclic Fatigue of Heat-Treated Nickel-Titanium Rotary Endodontic Instrument. Int J Dent 2021; 2021:6676005. [PMID: 33531902 PMCID: PMC7837779 DOI: 10.1155/2021/6676005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 01/06/2021] [Accepted: 01/09/2021] [Indexed: 11/18/2022] Open
Abstract
Peracetic acid (PAA) is widely used as a sterilizing/disinfecting agent, and, in endodontics, it has been introduced as a promising irrigant in root canal treatment. It has been used at different concentrations to achieve various functions. However, endodontic instruments in contact with PAA of a certain concentration may affect their fatigue resistance. Therefore, the aim of this study was to investigate the impact of PAA on the cyclic fatigue resistance of three commercial heat-treated nickel-titanium (NiTi) rotary files. Three types of heat-treated NiTi rotary files were selected: One Curve (OC), ProTaper Gold (PTG), and Wave One Gold (WOG). Each type was divided into three subgroups (n = 6 for each file type): (1) untreated instruments; (2) files immersed in 0.002% PAA; and (3) files immersed in 0.35% PAA. The performance of each file type was tested in a simulated canal. The number of cycles to fracture (NCF) was determined to assess cyclic fatigue resistance of the files. Independent sample t-test was applied to compare each treated file within a subgroup with its respective control group, and one-way ANOVA was used for comparison among the main groups. All types of tested files revealed a significant decline in the cyclic fatigue resistance after exposure to 0.002% PAA except the PTG (P=0.209). After exposure of the files to a higher concentration (0.35% PAA), a dramatic reduction was demonstrated by all the groups. Before and after exposure of the files to PAA, PTG displayed the highest cyclic fatigue resistance, followed by the WOG, while the OC showed the lowest resistance. Exposure of heated-treated NiTi files to PAA in a relatively high or low concentration adversely affects the cyclic fatigue resistance. The PTG files demonstrated the best performance among the tested types and can be disinfected with 0.002% PAA for clinical purpose.
Collapse
Affiliation(s)
| | - Zuha Ayad Jaber
- Department of Conservative Dentistry, Faculty of Dentistry, University of Kufa, Najaf, Iraq
| | | | - Abtesam Imhemed Aljdaimi
- College of Dentistry and Oral Surgery, Alasmarya of Dental Materials, Faculty of Dentistry, Sebha University, Sebha, Libya
| | | | - Saleh Zidan
- Department of Dental Materials, Faculty of Dentistry, Sebha University, Sebha, Libya
| | - Julfikar Haider
- Department of Engineering, Manchester Metropolitan University, Manchester M1 5GD, UK
| |
Collapse
|
16
|
Drukteinis S, Peciuliene V, Bendinskaite R, Brukiene V, Maneliene R, Rutkunas V. Shaping and Centering Ability, Cyclic Fatigue Resistance and Fractographic Analysis of Three Thermally Treated NiTi Endodontic Instrument Systems. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E5823. [PMID: 33371244 PMCID: PMC7766619 DOI: 10.3390/ma13245823] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Revised: 12/16/2020] [Accepted: 12/18/2020] [Indexed: 11/26/2022]
Abstract
The better understanding of the clinically important behavioral features of new instrument systems has an important significance for the clinical endodontics. This study aimed to investigate the shaping and centering ability as well as cyclic fatigue resistance of HyFlex CM (CM), HyFlex EDM (EDM) and EdgeFile (EF) thermally treated nickel-titanium (NiTi) endodontic instrument systems. Sixty curved root canals of the mesial roots of mandibular molars were randomly assigned into three groups (n = 20) and shaped using CM, EDM and EF files up to the size 40 and taper 04 of the instruments. µCT scanning of the specimens before and after preparation was performed and the morphometric 2D and 3D parameters were evaluated in the apical, middle and coronal thirds of root canals. In each group, 40.04 instruments (n = 20) were subjected to the cyclic fatigue resistance test in artificial root canals at 37 °C temperature until fractures occurred, and the number of cycles to failure (NCF) was calculated. The fractographic analysis was performed using a scanning electron microscope, evaluating topographic features and surface profiles of the separated instruments. The one-way analysis of variance with post hoc Tuckey's test was used for statistical analysis of the data; the significance level was set at 5%. All systems prepared the comparable percentage of root canal surface with the similar magnitude of canal transportation in all root thirds (p > 0.05), but demonstrated significantly different resistance to cyclic fatigue (p < 0.05). The most resistant to fracture was EF, followed by EDM and CM. The length of the fractured fragments was not significantly different between the groups, and fractographic analysis by SEM detected the typical topographic features of separated thermally treated NiTi instrument surfaces.
Collapse
Affiliation(s)
- Saulius Drukteinis
- Institute of Dentistry, Faculty of Medicine, Vilnius University, Zalgirio 115, LT-08217 Vilnius, Lithuania; (V.P.); (R.B.); (V.B.); (R.M.); (V.R.)
| | | | | | | | | | | |
Collapse
|
17
|
Resistance to Cyclic Fatigue of Nickel-Titanium Files Immersed in Sodium Hypochlorite at Body Temperature. Int J Dent 2020; 2020:8830163. [PMID: 33014060 PMCID: PMC7520684 DOI: 10.1155/2020/8830163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 09/06/2020] [Accepted: 09/08/2020] [Indexed: 11/17/2022] Open
Abstract
Materials and Methods Forty-five files from each brand were randomly assigned to three groups (n = 15) and subjected to the following: no immersion (control), 1-minute immersion, and 5-minute immersion in 2.5% NaOCl at 37°C. CF for all the files was tested within a well-lubricated stainless-steel artificial canal in a water bath at 37°C simulating body temperature. The procedure was video recorded, and the number of cycles to fracture (NCF) was calculated by multiplying the time taken to fracture, with the number of rotations per second. The data were analyzed for normality, and thereafter, one-way ANOVA with multiple Bonferroni was used as the post hoc test. Results The resistance to CF of OC files was significantly higher than PTG files in all groups. In groups immersed in NaOCl for one minute, OC files showed significant drop in the CF resistance; PTG files showed a drop as well but not significantly. Both files demonstrated a significant drop in resistance to CF after immersion in NaOCl for five minutes compared to the control group. Conclusion OC files were significantly more resistant to CF compared to PTG in all groups. Immersion in 2.5% NaOCl for 5 minutes significantly reduced the resistance to CF for all the files.
Collapse
|
18
|
Effects of Simultaneous Liquid or Gel Sodium Hypochlorite Irrigation on the Cyclic Fatigue of Two Single-File Nickel-Titanium Instruments. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10196666] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
To evaluate the effect of simultaneous liquid or gel sodium hypochlorite (NaOCl) irrigation on cyclic fatigue of F6 SkyTaper (F6ST) and OneCurve (OC) single files, 180 new 25/0.06 F6ST and OC files were divided into 6 groups (n = 15) for each brand. Groups 1 and 4 included new instruments not exposed to NaOCl at 20 °C and 37 °C, respectively. Groups 2 and 5 included files activated with liquid NaOCl at 20 °C and 37 °C, respectively. Groups 3 and 6 consisted of instruments tested with NaOCl gel at 20 °C and 37 °C, respectively. Instruments were subjected to a fatigue test using a novel customized device. Data were expressed as time to fracture (TtF) and statistically analyzed (p < 0.05) after checking their normality through the Shapiro–Wilk test. Because they were normally distributed, 2-way analyses of variance (ANOVA) and the Tukey multiple comparison post-hoc test were used. Time to fracture of all tested instruments decreased at 37 °C (p < 0.05). At 20 °C, NaOCl improved TtF of F6ST and OC (p < 0.05). NaOCl liquid increased TtF of F6ST (p < 0.05) in comparison with gel, while there was no difference between the two formulations for OC. At 37 °C, both NaOCl formulations had no significant influence on TtF for F6ST, while they increased TtF of OC (p < 0.05). NaOCl improved the cyclic fatigue resistance of OC, independently of the temperature, while for F6ST the negative impact of higher temperature reduced the irrigant benefits.
Collapse
|