Laundon D, Lane T, Katsamenis OL, Norman J, Brewer L, Harris SE, Basford PJ, Shotton J, Free D, Constable-Dakeyne G, Gostling NJ, Chavatte-Palmer P, Lewis RM. Correlative three-dimensional X-ray histology (3D-XRH) as a tool for quantifying mammalian placental structure. Placenta 2024:S0143-4004(24)00607-6. [PMID: 39097490 DOI: 10.1016/j.placenta.2024.07.312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 07/15/2024] [Accepted: 07/30/2024] [Indexed: 08/05/2024]
Abstract
Mammalian placentas exhibit unparalleled structural diversity, despite sharing a common ancestor and principal functions. The bulk of structural studies in placental research has used two-dimensional (2D) histology sectioning, allowing significant advances in our understanding of mammalian placental structure. However, 2D histology sectioning may be limited if it does not provide accurate information of three-dimensional (3D) tissue architecture. Here, we propose correlative 3D X-ray histology (3D-XRH) as a tool with great potential for resolving mammalian placental structures. 3D-XRH involves scanning a formaldehyde-fixed, paraffin embedded (FFPE) tissue block with 3D X-ray microscopy (microCT) prior to histological sectioning to generate a 3D image volume of the embedded tissue piece. The subsequent 2D histology sections can then be correlated back into the microCT image volume to couple histology staining (or immunolabelling) with 3D tissue architecture. 3D-XRH is non-destructive and requires no additional sample preparation than standard FFPE histology sectioning, however the image volume provides 3D morphometric data and can be used to guide microtomy. As such, 3D-XRH introduces additional information to standard histological workflows with minimal effort or disruption. Using primary examples from porcine, bovine, equine, and canine placental samples, we demonstrate the application of 3D-XRH to quantifying placental structure as well as discussing the limitations and future directions of the methodology. The wealth of information derived from 2D histological sectioning in the biomedical, veterinary, and comparative reproductive sciences provides a rich foundation from which 3D-XRH can build on to advance the study of placental structure and function.
Collapse
Affiliation(s)
- Davis Laundon
- The Institute of Developmental Sciences, Human Development and Health, Faculty of Medicine, University of Southampton, Southampton, SO16 6YD, UK; Institute for Life Sciences, University of Southampton, University Rd, Highfield, Southampton, SO17 1BJ, UK.
| | - Thomas Lane
- School of Biological Sciences, Faculty of Environmental and Life Sciences, University of Southampton, University Rd, Highfield, Southampton, SO17 1BJ, UK
| | - Orestis L Katsamenis
- Institute for Life Sciences, University of Southampton, University Rd, Highfield, Southampton, SO17 1BJ, UK; μ-VIS X-Ray Imaging Centre, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, SO17 1BJ, UK
| | - Jeanette Norman
- Histochemistry Research Facility, Faculty of Medicine, University of Southampton, Southampton, SO16 6YD, UK
| | - Lois Brewer
- School of Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, University Road, Southampton, SO17 1BJ, UK
| | - Shelley E Harris
- The Institute of Developmental Sciences, Human Development and Health, Faculty of Medicine, University of Southampton, Southampton, SO16 6YD, UK
| | - Philip J Basford
- Institute for Life Sciences, University of Southampton, University Rd, Highfield, Southampton, SO17 1BJ, UK; μ-VIS X-Ray Imaging Centre, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, SO17 1BJ, UK; School of Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, University Road, Southampton, SO17 1BJ, UK
| | - Justine Shotton
- Marwell Wildlife, Thompson's Ln, Colden Common, Winchester, SO21 1JH, UK
| | - Danielle Free
- Marwell Wildlife, Thompson's Ln, Colden Common, Winchester, SO21 1JH, UK
| | | | - Neil J Gostling
- Institute for Life Sciences, University of Southampton, University Rd, Highfield, Southampton, SO17 1BJ, UK; School of Biological Sciences, Faculty of Environmental and Life Sciences, University of Southampton, University Rd, Highfield, Southampton, SO17 1BJ, UK
| | - Pascale Chavatte-Palmer
- Université Paris-Saclay, UVSQ, INRAE, BREED, 78350, Jouy-en-Josas, France; Ecole Nationale Vétérinaire d'Alfort, BREED, 94700, Maisons-Alfort, France
| | - Rohan M Lewis
- The Institute of Developmental Sciences, Human Development and Health, Faculty of Medicine, University of Southampton, Southampton, SO16 6YD, UK; Institute for Life Sciences, University of Southampton, University Rd, Highfield, Southampton, SO17 1BJ, UK
| |
Collapse
|
2
|
Dizbay Sak S, Sevim S, Buyuksungur A, Kayı Cangır A, Orhan K. The Value of Micro-CT in the Diagnosis of Lung Carcinoma: A Radio-Histopathological Perspective. Diagnostics (Basel) 2023; 13:3262. [PMID: 37892083 PMCID: PMC10606474 DOI: 10.3390/diagnostics13203262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 10/12/2023] [Accepted: 10/17/2023] [Indexed: 10/29/2023] Open
Abstract
Micro-computed tomography (micro-CT) is a relatively new imaging modality and the three-dimensional (3D) images obtained via micro-CT allow researchers to collect both quantitative and qualitative information on various types of samples. Micro-CT could potentially be used to examine human diseases and several studies have been published on this topic in the last decade. In this study, the potential uses of micro-CT in understanding and evaluating lung carcinoma and the relevant studies conducted on lung and other tumors are summarized. Currently, the resolution of benchtop laboratory micro-CT units has not reached the levels that can be obtained with light microscopy, and it is not possible to detect the histopathological features (e.g., tumor type, adenocarcinoma pattern, spread through air spaces) required for lung cancer management. However, its ability to provide 3D images in any plane of section, without disturbing the integrity of the specimen, suggests that it can be used as an auxiliary technique, especially in surgical margin examination, the evaluation of tumor invasion in the entire specimen, and calculation of primary and metastatic tumor volume. Along with future developments in micro-CT technology, it can be expected that the image resolution will gradually improve, the examination time will decrease, and the relevant software will be more user friendly. As a result of these developments, micro-CT may enter pathology laboratories as an auxiliary method in the pathological evaluation of lung tumors. However, the safety, performance, and cost effectiveness of micro-CT in the areas of possible clinical application should be investigated. If micro-CT passes all these tests, it may lead to the convergence of radiology and pathology applications performed independently in separate units today, and the birth of a new type of diagnostician who has equal knowledge of the histological and radiological features of tumors.
Collapse
Affiliation(s)
- Serpil Dizbay Sak
- Department of Pathology, Faculty of Medicine, Ankara University, Ankara 06230, Turkey
| | - Selim Sevim
- Department of Pathology, Faculty of Medicine, Ankara University, Ankara 06230, Turkey
| | - Arda Buyuksungur
- Department of Basic Medical Sciences, Faculty of Dentistry, Ankara University, Ankara 06560, Turkey
| | - Ayten Kayı Cangır
- Department of Thoracic Surgery Ankara, Faculty of Medicine, Ankara University, Ankara 06230, Turkey
| | - Kaan Orhan
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara 06560, Turkey
| |
Collapse
|
3
|
OCT Meets micro-CT: A Subject-Specific Correlative Multimodal Imaging Workflow for Early Chick Heart Development Modeling. J Cardiovasc Dev Dis 2022; 9:jcdd9110379. [DOI: 10.3390/jcdd9110379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/29/2022] [Accepted: 10/31/2022] [Indexed: 11/06/2022] Open
Abstract
Structural and Doppler velocity data collected from optical coherence tomography have already provided crucial insights into cardiac morphogenesis. X-ray microtomography and other ex vivo methods have elucidated structural details of developing hearts. However, by itself, no single imaging modality can provide comprehensive information allowing to fully decipher the inner workings of an entire developing organ. Hence, we introduce a specimen-specific correlative multimodal imaging workflow combining OCT and micro-CT imaging which is applicable for modeling of early chick heart development—a valuable model organism in cardiovascular development research. The image acquisition and processing employ common reagents, lab-based micro-CT imaging, and software that is free for academic use. Our goal is to provide a step-by-step guide on how to implement this workflow and to demonstrate why those two modalities together have the potential to provide new insight into normal cardiac development and heart malformations leading to congenital heart disease.
Collapse
|