• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4605581)   Today's Articles (0)   Subscriber (49373)
For: Smart CM, Primrose CW, Peters AL, Speirits EJ. The properties of an improvised piston pump for the rapid delivery of intravenous fluids. Anaesthesia 2014;69:111-7. [PMID: 24383681 DOI: 10.1111/anae.12463] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/07/2013] [Indexed: 11/27/2022]
Number Cited by Other Article(s)
1
Maki J, Sumie M, Ide T, Nagamatsu M, Matsushita K, Shirozu K, Higashi M, Yamaura K. A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study. BMC Anesthesiol 2022;22:205. [PMID: 35787789 PMCID: PMC9252047 DOI: 10.1186/s12871-022-01738-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Accepted: 06/20/2022] [Indexed: 11/21/2022]  Open
2
When Minutes Matter: Rapid Infusion in Emergency Care. CURRENT EMERGENCY AND HOSPITAL MEDICINE REPORTS 2021. [DOI: 10.1007/s40138-021-00237-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
3
Hashimoto W, Takenaka I, Yasunami K, Minami T, Sano H. Comparison of effectiveness of the piston-pump method versus the pressure-infusor method for rapid infusion of crystalloids: A bench study. Indian J Anaesth 2021;64:1059-1063. [PMID: 33542570 PMCID: PMC7852453 DOI: 10.4103/ija.ija_864_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 08/11/2020] [Accepted: 09/29/2020] [Indexed: 11/04/2022]  Open
4
Efficacy of Rapid Fluid Administration Using Various Setups and Devices. Pediatr Emerg Care 2019;35:539-543. [PMID: 31373949 DOI: 10.1097/pec.0000000000001235] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
5
In-line pressure within a HOTLINE® Fluid Warmer, under various flow conditions. J Clin Monit Comput 2014;29:301-5. [PMID: 25087123 DOI: 10.1007/s10877-014-9605-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2014] [Accepted: 07/26/2014] [Indexed: 10/24/2022]
6
Smart C. A reply. Anaesthesia 2014;69:388-9. [DOI: 10.1111/anae.12647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
7
Maddock A, Li L. Re-inventing the piston pump. Anaesthesia 2014;69:387. [DOI: 10.1111/anae.12646] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
8
McPherson D. Is flow really laminar in a piston pump infusion? Anaesthesia 2014;69:387-8. [DOI: 10.1111/anae.12653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
PrevPage 1 of 1 1Next