1
|
Bjørdalsbakke NL, Sturdy J, Wisløff U, Hellevik LR. Examining temporal changes in model-optimized parameters using longitudinal hemodynamic measurements. Biomed Eng Online 2024; 23:64. [PMID: 38982471 PMCID: PMC11234604 DOI: 10.1186/s12938-024-01242-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Accepted: 04/30/2024] [Indexed: 07/11/2024] Open
Abstract
BACKGROUND We previously applied hemodynamic data to personalize a mathematical model of the circulation expressed as physically interpretable parameters. The aim of this study was to identify patterns in the data that could potentially explain the estimated parameter changes. This included investigating whether the parameters could be used to track the effect of physical activity on high blood pressure. Clinical trials have repeatedly detected beneficial changes in blood pressure after physical activity and uncovered changes in lower level phenotypes (such as stiffened or high-resistance blood vessels). These phenotypes can be characterized by parameters describing the mechanical properties of the circulatory system. These parameters can be incorporated in and contextualized by physics-based cardiovascular models of the circulation, which in combination can become tools for monitoring cardiovascular disease progression and management in the future. METHODS Closed-loop and open-loop models of the left ventricle and systemic circulation were previously optimized to data from a pilot study with a 12-week exercise intervention period. Basal characteristics and hemodynamic data such as blood pressure in the carotid, brachial and finger arteries, as well as left-ventricular outflow tract flow traces were collected in the trial. Model parameters estimated for measurements made on separate days during the trial were used to compute parameter changes for total peripheral resistance, systemic arterial compliance, and maximal left-ventricular elastance. We compared the changes in these cardiovascular model-based estimates to changes from more conventional estimates made without the use of physics-based models by correlation analysis. Additionally, ordinary linear regression and linear mixed-effects models were applied to determine the most informative measurements for the selected parameters. We applied maximal aerobic capacity (measured as VO2max ) data to examine if exercise had any impact on parameters through regression analysis and case studies. RESULTS AND CONCLUSIONS Parameter changes in arterial parameters estimated using the cardiovascular models correlated moderately well with conventional estimates. Estimates based on carotid pressure waveforms gave higher correlations (0.59 and above when p < 0.05 ) than those for finger arterial pressure. Parameter changes over the 12-week study duration were of similar magnitude when compared to short-term changes after a bout of intensive exercise in the same parameters. The short-term changes were computed from measurements made immediately before and 24 h after a cardiopulmonary exercise test used to measure VO2max . Regression analysis indicated that changes in VO2max did not account for any substantial amount of variability in total peripheral resistance, systemic arterial compliance, or maximal left-ventricular elastance. On the contrary, changes in stroke volume contributed to far more explained variability. The results suggest that more research is required to be able to accurately track exercise-induced changes in the vasculature for people with pre-hypertension and hypertension using lumped-parameter models.
Collapse
Affiliation(s)
- Nikolai L Bjørdalsbakke
- Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), Richard Birkelandsvei 1A, Trondheim, 7491, Norway.
| | - Jacob Sturdy
- Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), Richard Birkelandsvei 1A, Trondheim, 7491, Norway
| | - Ulrik Wisløff
- Cardiac Exercise Research Group at the Department of Circulation and Medical Imaging, Norwegian University of Science and Technology (NTNU), Prinsesse Kristinas gate 3, Trondheim, 7491, Norway
| | - Leif R Hellevik
- Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), Richard Birkelandsvei 1A, Trondheim, 7491, Norway
| |
Collapse
|
2
|
Grant MC, Salenger R, Lobdell KW. Perioperative hemodynamic monitoring in cardiac surgery. Curr Opin Anaesthesiol 2024; 37:1-9. [PMID: 38085877 DOI: 10.1097/aco.0000000000001327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2023]
Abstract
PURPOSE OF REVIEW Cardiac surgery has traditionally relied upon invasive hemodynamic monitoring, including regular use of pulmonary artery catheters. More recently, there has been advancement in our understanding as well as broader adoption of less invasive alternatives. This review serves as an outline of the key perioperative hemodynamic monitoring options for cardiac surgery. RECENT FINDINGS Recent study has revealed that the use of invasive monitoring such as pulmonary artery catheters or transesophageal echocardiography in low-risk patients undergoing low-risk cardiac surgery is of questionable benefit. Lesser invasive approaches such a pulse contour analysis or ultrasound may provide a useful alternative to assess patient hemodynamics and guide resuscitation therapy. A number of recent studies have been published to support broader indication for these evolving technologies. SUMMARY More selective use of indwelling catheters for cardiac surgery has coincided with greater application of less invasive alternatives. Understanding the advantages and limitations of each tool allows the bedside clinician to identify which hemodynamic monitoring modality is most suitable for which patient.
Collapse
Affiliation(s)
- Michael C Grant
- Department of Anesthesiology and Critical Care Medicine, The Johns Hopkins University School of Medicine
| | - Rawn Salenger
- Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland
| | - Kevin W Lobdell
- Sanger Heart & Vascular Institute, Advocate Health, Charlotte, North Carolina, USA
| |
Collapse
|
3
|
Meng L, Sun Y, Zhao X, Meng DM, Liu Z, Adams DC, McDonagh DL, Rasmussen M. Effects of phenylephrine on systemic and cerebral circulations in humans: a systematic review with mechanistic explanations. Anaesthesia 2024; 79:71-85. [PMID: 37948131 DOI: 10.1111/anae.16172] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/03/2023] [Indexed: 11/12/2023]
Abstract
We conducted a systematic review of the literature reporting phenylephrine-induced changes in blood pressure, cardiac output, cerebral blood flow and cerebral tissue oxygen saturation as measured by near-infrared spectroscopy in humans. We used the proportion change of the group mean values reported by the original studies in our analysis. Phenylephrine elevates blood pressure whilst concurrently inducing a reduction in cardiac output. Furthermore, despite increasing cerebral blood flow, it decreases cerebral tissue oxygen saturation. The extent of phenylephrine's influence on cardiac output (r = -0.54 and p = 0.09 in awake humans; r = -0.55 and p = 0.007 in anaesthetised humans), cerebral blood flow (r = 0.65 and p = 0.002 in awake humans; r = 0.80 and p = 0.003 in anaesthetised humans) and cerebral tissue oxygen saturation (r = -0.72 and p = 0.03 in awake humans; r = -0.24 and p = 0.48 in anaesthetised humans) appears closely linked to the magnitude of phenylephrine-induced blood pressure changes. When comparing the effects of phenylephrine in awake and anaesthetised humans, we found no evidence of a significant difference in cardiac output, cerebral blood flow or cerebral tissue oxygen saturation. There was also no evidence of a significant difference in effect on systemic and cerebral circulations whether phenylephrine was given by bolus or infusion. We explore the underlying mechanisms driving the phenylephrine-induced cardiac output reduction, cerebral blood flow increase and cerebral tissue oxygen saturation decrease. Individualised treatment approaches, close monitoring and consideration of potential risks and benefits remain vital to the safe and effective use of phenylephrine in acute care.
Collapse
Affiliation(s)
- L Meng
- Department of Anesthesia, Indiana University School of Medicine, IA, Indianapolis, USA
| | - Y Sun
- Department of Anesthesiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Nanjing University Medical School, Nanjing, China
| | - X Zhao
- Department of Anesthesiology, First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - D M Meng
- Choate Rosemary Hall School, CT, Wallingford, USA
| | - Z Liu
- Department of Biostatistics and Health Data Science, Indiana University School of Medicine, IA, Indianapolis, USA
| | - D C Adams
- Department of Anesthesia, Indiana University School of Medicine, IA, Indianapolis, USA
| | - D L McDonagh
- Departments of Anesthesiology and Pain Management, Neurological Surgery, Neurology and Neurotherapeutics, UT Southwestern Medical Center, TX, Dallas, USA
| | - M Rasmussen
- Department of Anesthesiology, Section of Neuroanesthesia, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
4
|
Suehiro K. Assessing fluid responsiveness during spontaneous breathing. J Anesth 2022; 36:579-582. [PMID: 35606608 DOI: 10.1007/s00540-022-03075-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2022] [Accepted: 05/04/2022] [Indexed: 11/26/2022]
Affiliation(s)
- Koichi Suehiro
- Department of Anesthesiology, Osaka Metropolitan University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka City, Osaka, 545-8586, Japan.
| |
Collapse
|
5
|
Lawton JS, Tamis-Holland JE, Bangalore S, Bates ER, Beckie TM, Bischoff JM, Bittl JA, Cohen MG, DiMaio JM, Don CW, Fremes SE, Gaudino MF, Goldberger ZD, Grant MC, Jaswal JB, Kurlansky PA, Mehran R, Metkus TS, Nnacheta LC, Rao SV, Sellke FW, Sharma G, Yong CM, Zwischenberger BA. 2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. J Am Coll Cardiol 2022; 79:e21-e129. [PMID: 34895950 DOI: 10.1016/j.jacc.2021.09.006] [Citation(s) in RCA: 677] [Impact Index Per Article: 225.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
AIM The guideline for coronary artery revascularization replaces the 2011 coronary artery bypass graft surgery and the 2011 and 2015 percutaneous coronary intervention guidelines, providing a patient-centric approach to guide clinicians in the treatment of patients with significant coronary artery disease undergoing coronary revascularization as well as the supporting documentation to encourage their use. METHODS A comprehensive literature search was conducted from May 2019 to September 2019, encompassing studies, reviews, and other evidence conducted on human subjects that were published in English from PubMed, EMBASE, the Cochrane Collaboration, CINHL Complete, and other relevant databases. Additional relevant studies, published through May 2021, were also considered. STRUCTURE Coronary artery disease remains a leading cause of morbidity and mortality globally. Coronary revascularization is an important therapeutic option when managing patients with coronary artery disease. The 2021 coronary artery revascularization guideline provides recommendations based on contemporary evidence for the treatment of these patients. The recommendations present an evidence-based approach to managing patients with coronary artery disease who are being considered for coronary revascularization, with the intent to improve quality of care and align with patients' interests.
Collapse
|
6
|
Lawton JS, Tamis-Holland JE, Bangalore S, Bates ER, Beckie TM, Bischoff JM, Bittl JA, Cohen MG, DiMaio JM, Don CW, Fremes SE, Gaudino MF, Goldberger ZD, Grant MC, Jaswal JB, Kurlansky PA, Mehran R, Metkus TS, Nnacheta LC, Rao SV, Sellke FW, Sharma G, Yong CM, Zwischenberger BA. 2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation 2022; 145:e18-e114. [PMID: 34882435 DOI: 10.1161/cir.0000000000001038] [Citation(s) in RCA: 202] [Impact Index Per Article: 67.3] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
7
|
Mukai A, Suehiro K, Kimura A, Tanaka K, Yamada T, Mori T, Nishikawa K. Effect of Systemic Vascular Resistance on the Reliability of Noninvasive Hemodynamic Monitoring in Cardiac Surgery. J Cardiothorac Vasc Anesth 2020; 35:1782-1791. [PMID: 33279380 DOI: 10.1053/j.jvca.2020.11.011] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 10/31/2020] [Accepted: 11/06/2020] [Indexed: 11/11/2022]
Abstract
OBJECTIVE To assess the effect of systemic vascular resistance (SVR) on the reliability of the ClearSight system (Edwards Lifesciences, Irvine, CA) for measuring blood pressure (BP) and cardiac output (CO). DESIGN Observational study. SETTING University hospital. PARTICIPANTS Twenty-five patients undergoing cardiac surgery. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS BP, measured using ClearSight and an arterial line, and CO, measured using ClearSight and a pulmonary artery catheter, were recorded before (T1) and two minutes after phenylephrine or ephedrine administration. Bland-Altman analysis was used to compare BP and CO measurements at T1. A polar plot was used to assess trending abilities. Patients were divided into the following three groups according to the SVR index (SVRI) at T1: low (<1,200 dyne s/cm5/m2), normal (1,200-25,00 dyne s/cm5/m2), and high (>2,500 dyne s/cm5/m2). The bias in BP and CO was -4.8 ± 8.9 mmHg and 0.10 ± 0.81 L/min, respectively, which was correlated significantly with SVRI (p < 0.05). The percentage error in CO was 40.6%, which was lower in the normal SVRI group (33.3%) than the low and high groups (46.3% and 47.7%, respectively). The angular concordance rate was 96.3% and 95.4% for BP and 87.0% and 92.5% for CO after phenylephrine and ephedrine administration, respectively. There was a low tracking ability for CO changes after phenylephrine administration in the low-SVRI group (angular concordance rate 33.3%). CONCLUSION The ClearSight system showed an acceptable accuracy in measuring BP and tracking BP changes in various SVR states; however, the accuracy of CO measurement and its trending ability in various SVR states was poor.
Collapse
Affiliation(s)
- Akira Mukai
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, Osaka City, Osaka, Japan
| | - Koichi Suehiro
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, Osaka City, Osaka, Japan.
| | - Aya Kimura
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, Osaka City, Osaka, Japan
| | - Katsuaki Tanaka
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, Osaka City, Osaka, Japan
| | - Tokuhiro Yamada
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, Osaka City, Osaka, Japan
| | - Takashi Mori
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, Osaka City, Osaka, Japan
| | - Kiyonobu Nishikawa
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, Osaka City, Osaka, Japan
| |
Collapse
|
8
|
Grønlykke L, Korshin A, Holmgaard F, Kjøller SM, Gustafsson F, Nilsson JC, Ravn HB. Severe loss of right ventricular longitudinal contraction occurs after cardiopulmonary bypass in patients with preserved right ventricular output. Int J Cardiovasc Imaging 2019; 35:1661-1670. [DOI: 10.1007/s10554-019-01616-7] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Accepted: 04/25/2019] [Indexed: 11/28/2022]
|
9
|
Skowno JJ. Hemodynamic monitoring in children with heart disease: Overview of newer technologies. Paediatr Anaesth 2019; 29:467-474. [PMID: 30667124 DOI: 10.1111/pan.13590] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Revised: 12/26/2018] [Accepted: 01/14/2019] [Indexed: 12/21/2022]
Affiliation(s)
- Justin J Skowno
- Department of Anaesthesia, The Children's Hospital at Westmead, Sydney, NSW, Australia.,Discipline of Child and Adolescent Health, Faculty of Medicine and Health, The University of Sydney, NSW, Australia
| |
Collapse
|
10
|
Juri T, Suehiro K, Kimura A, Mukai A, Tanaka K, Yamada T, Mori T, Nishikawa K. Impact of non-invasive continuous blood pressure monitoring on maternal hypotension during cesarean delivery: a randomized-controlled study. J Anesth 2018; 32:822-830. [PMID: 30267340 DOI: 10.1007/s00540-018-2560-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2018] [Accepted: 09/21/2018] [Indexed: 12/24/2022]
Abstract
PURPOSE This study aimed to investigate the efficacy of the ClearSight™ system (Edwards Lifesciences, Irvine, CA) for reducing the incidence of hypotension compared with the traditional oscillometric blood pressure monitoring in cesarean delivery under spinal anesthesia. METHODS Forty patients undergoing cesarean delivery under spinal anesthesia were enrolled. The patients were randomly divided into two groups (Control and ClearSight groups). All patients received spinal anesthesia using 0.5% hyperbaric bupivacaine (11.5 mg) and fentanyl (10 µg). Blood pressure was managed with the same protocol using the ClearSight™ system (ClearSight group) and oscillometric blood pressure monitoring (Control group). Furthermore, we compared the accuracy of the ClearSight™ system with the traditional oscillometric monitoring for blood pressure measurement using Bland-Altman, four-quadrant plot, and polar plot analyses. RESULTS The incidence of hypotension was significantly lower in the ClearSight group from induction to delivery (45% vs. 0%, p < 0.001) and to the end of surgery (50% vs. 20%, p = 0.049). Intraoperative nausea occurred more frequently in the Control group (45% vs. 10%, p = 0.012). The ClearSight™ system demonstrated acceptable accuracy with a bias of - 4.3 ± 11.7 mmHg throughout the procedure. Four-quadrant analysis revealed an excellent trending ability of the ClearSight™ system with a concordance rate of approximately 95%. In the polar plot analysis, the angular bias and concordance rate were - 13.5° ± 19.0° and 76.9%, respectively. CONCLUSIONS The accuracy and trending ability of the ClearSight™ system for blood pressure measurement was clinically acceptable in cesarean delivery under spinal anesthesia, leading to reductions in maternal hypotension and nausea.
Collapse
Affiliation(s)
- Takashi Juri
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan
| | - Koichi Suehiro
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan.
| | - Aya Kimura
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan
| | - Akira Mukai
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan
| | - Katsuaki Tanaka
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan
| | - Tokuhiro Yamada
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan
| | - Takashi Mori
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan
| | - Kiyonobu Nishikawa
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan
| |
Collapse
|
11
|
Alruwaili F, Cluff K, Griffith J, Farhoud H. Passive Self Resonant Skin Patch Sensor to Monitor Cardiac Intraventricular Stroke Volume Using Electromagnetic Properties of Blood. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE-JTEHM 2018; 6:1900709. [PMID: 30416893 PMCID: PMC6214405 DOI: 10.1109/jtehm.2018.2870589] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2018] [Revised: 05/29/2018] [Accepted: 09/04/2018] [Indexed: 12/24/2022]
Abstract
This paper focuses on the development of a passive, lightweight skin patch sensor that can measure fluid volume changes in the heart in a non-invasive, point-of-care setting. The wearable sensor is an electromagnetic, self-resonant sensor configured into a specific pattern to formulate its three passive elements (resistance, capacitance, and inductance). In an animal model, a bladder was inserted into the left ventricle (LV) of a bovine heart, and fluid was injected using a syringe to simulate stoke volume (SV). In a human study, to assess the dynamic fluid volume changes of the heart in real time, the sensor frequency response was obtained from a participant in a 30° head-up tilt (HUT), 10° HUT, supine, and 10° head-down tilt positions over time. In the animal model, an 80-mL fluid volume change in the LV resulted in a downward frequency shift of 80.16 kHz. In the human study, there was a patterned frequency shift over time which correlated with ventricular volume changes in the heart during the cardiac cycle. Statistical analysis showed a linear correlation \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{upgreek}
\usepackage{mathrsfs}
\setlength{\oddsidemargin}{-69pt}
\begin{document}
}{}${R} ^{2} = 0.98$
\end{document} and 0.87 between the frequency shifts and fluid volume changes in the LV of the bovine heart and human participant, respectively. In addition, the patch sensor detected heart rate in a continuous manner with a 0.179% relative error compared to electrocardiography. These results provide promising data regarding the ability of the patch sensor to be a potential technology for SV monitoring in a non-invasive, continuous, and non-clinical setting.
Collapse
Affiliation(s)
- Fayez Alruwaili
- Biomedical Engineering DepartmentWichita State UniversityWichitaKS67260USA
| | - Kim Cluff
- Biomedical Engineering DepartmentWichita State UniversityWichitaKS67260USA
| | - Jacob Griffith
- Biomedical Engineering DepartmentWichita State UniversityWichitaKS67260USA
| | | |
Collapse
|
12
|
Impact of continuous non-invasive blood pressure monitoring on hemodynamic fluctuation during general anesthesia: a randomized controlled study. J Clin Monit Comput 2018; 32:1005-1013. [DOI: 10.1007/s10877-018-0125-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2017] [Accepted: 03/02/2018] [Indexed: 10/17/2022]
|
13
|
Lee SH, Choi YS, Hong GR, Oh YJ. Echocardiographic evaluation of the effects of dexmedetomidine on cardiac function during total intravenous anaesthesia. Anaesthesia 2015; 70:1052-9. [DOI: 10.1111/anae.13084] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/03/2015] [Indexed: 12/26/2022]
Affiliation(s)
- S. H. Lee
- Department of Anaesthesiology and Pain Medicine, and Anaesthesia and Pain Research Institute; Yonsei University College of Medicine; Seoul Korea
| | - Y. S. Choi
- Department of Anaesthesiology and Pain Medicine, and Anaesthesia and Pain Research Institute; Yonsei University College of Medicine; Seoul Korea
| | - G. R. Hong
- Division of Cardiology, Severance Cardiovascular Hospital; Yonsei University College of Medicine; Seoul Korea
| | - Y. J. Oh
- Department of Anaesthesiology and Pain Medicine, and Anaesthesia and Pain Research Institute; Yonsei University College of Medicine; Seoul Korea
| |
Collapse
|