1
|
Abdelnaby P, Ibrahim M, ElBackly R. In vitro evaluation of filling material removal and apical debris extrusion after retreatment using Reciproc blue, Hyflex EDM and ProTaper retreatment files. BMC Oral Health 2023; 23:902. [PMID: 37990209 PMCID: PMC10664678 DOI: 10.1186/s12903-023-03579-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Accepted: 10/25/2023] [Indexed: 11/23/2023] Open
Abstract
OBJECTIVES To evaluate the amount of remaining filing material and apical debris extrusion after retreatment using Reciproc Blue, Hyflex EDM and ProTaper Retreatment Files. MATERIALS AND METHODS Thirty-six extracted permanent mandibular first molars with moderately curved mesial roots were selected. Mesiobuccal canals were prepared using the ProTaper Next system up to size X2 and filled using gutta-percha and Adseal sealer via cold lateral compaction. Teeth were randomly divided into three equal groups (n = 12): Group 1: Reciproc Blue (RB)(VDW, Germany), Group 2: Hyflex EDM (HEDM)(Coltene/Whaledent, Switzerland), Group 3: ProTaper Universal Retreatment file system + ProTaper Next file system (PTUR + PTN)( Dentsply Maillefer, Switzerland). Eppendorf tubes were used to collect the apically extruded debris. Cone-beam computed tomographic scans were taken prior to and after retreatment and the volume of remaining filling material was assessed at the coronal, middle and apical levels. Statistical analysis was performed using the Kruskal-Wallis test, Friedman's test and Wilcoxon Sign Rank test. Significance level was set at p value 0.05. RESULTS There were no statistically significant differences among the three groups in the reduction of the volume of the filling material or in the amount of apically extruded debris. CONCLUSION All the tested filing systems showed similar efficacy in removing the filling material, however, none of them could achieve its complete removal. Apical extrusion of debris occurred with all the systems used with no significant difference between the three groups.
Collapse
Affiliation(s)
- Passent Abdelnaby
- Conservative Dentistry Department, MS Student, Endodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Mohamed Ibrahim
- Conservative Dentistry Department, Endodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Rania ElBackly
- Conservative Dentistry Department, Endodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
- Tissue Engineering Laboratories, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
| |
Collapse
|
2
|
Laslami K, Khaldoune S, Sy A, Drouri S, Benkiran I. Apical Extrusion: Is It an Inherent Occurrence During Every Endodontic Treatment? Cureus 2023; 15:e45211. [PMID: 37720124 PMCID: PMC10504573 DOI: 10.7759/cureus.45211] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/06/2023] [Indexed: 09/19/2023] Open
Abstract
The aim of this literature review was to analyze all available scientific data on apical extrusion and to identify and associate the possible factors influencing the occurrence of apical extrusion, ranging from the choice of the canal shaping system, the irrigation technique, to the choice of diameter and the apical limit of preparation. A bibliographic search for relevant articles on apical extrusion of debris, irrigants, and bacteria was performed using the following databases: PubMed, Cochrane Library, and ScienceDirect. This search identified articles published between 2010 and 2023 in two languages (French and English). After selective sorting, 25 relevant documents were included. All the studies retained clearly agree on the inherent nature of apical extrusion during endodontic treatment. At the same time, we also understand that the amount of extrusion can be influenced by a number of parameters throughout endodontic therapy. According to this review, despite the undeniable nature of apical extrusion during endodontic therapy, studies with relatable experimental models that approach in vivo conditions are required to establish exploitable conclusions regarding apical extrusion and its prevention.
Collapse
Affiliation(s)
- Kaoutar Laslami
- Department of Conservative Dentistry and Endodontics, Faculty of Dental Medicine, University Hassan II, Casablanca, MAR
| | - Salma Khaldoune
- Department of Conservative Dentistry and Endodontics, Faculty of Dental Medicine, University Hassan II, Casablanca, MAR
| | - Aly Sy
- Department of Conservative Dentistry and Endodontics, Faculty of Dental Medicine, University Hassan II, Casablanca, MAR
| | - Sofia Drouri
- Department of Conservative Dentistry and Endodontics, Faculty of Dental Medicine, University Hassan II, Casablanca, MAR
| | - Imane Benkiran
- Department of Conservative Dentistry and Endodontics, Faculty of Dental Medicine, University Hassan II, Casablanca, MAR
| |
Collapse
|
3
|
Uygun AD. Comparison of apical debris extrusion of different generation nickel-titanium instrument systems. Niger J Clin Pract 2022; 25:2010-2015. [PMID: 36537459 DOI: 10.4103/njcp.njcp_455_22] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
BACKGROUND AND AIM The aim of this study is to evaluate the apical debris extrusion amounts and preparation times of four different nickel-titanium systems with a similar cross-section design-Mtwo, RECIPROC, RECIPROC blue, and VDW.ROTATE. MATERIALS AND METHODS Eighty human mandibular central incisors were divided into four equal groups (n = 20). The test apparatus was inserted into an assembly that provided root canal temperature. Preparation times were recorded using a stopwatch, and the amount of extruded debris was collected in pre-weighed Eppendorf tubes. After drying, the net amount was determined by subtracting the previously measured Eppendorf tube weights from the total weight. RESULTS The Mtwo had the largest amount of debris, but there was no significant difference among the other groups. The VDW.ROTATE completed the preparation in a significantly shorter time than the RECIPROC blue and Mtwo. CONCLUSION Compared to other files, the Mtwo sequence produced significantly more debris and required significantly more time to complete the whole root canal preparation.
Collapse
Affiliation(s)
- A D Uygun
- Department of Endodontics, Faculty of Dentistry, Afyonkarahisar Health Sciences University, Afyonkarahisar, Turkey
| |
Collapse
|
4
|
Quantitative Evaluation of Apically Extruded Debris of Root Canal Dentin Layer with WaveOne, ProTaper Next, ProTaper Gold Rotary File Systems. COATINGS 2022. [DOI: 10.3390/coatings12040451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Endodontic flare-up or post-operative pain occurs when debris such as necrotic pulp tissue, dentin chips, irrigants, and microorganisms are extruded from the apical foramen intraoperatively into the periradicular tissue during root canal instrumentation. This study compared the amount of apical debris extrusion of the root canal dentin layer after using reciprocating and rotary file systems (WaveOne, ProTaper Next and ProTaper Gold). Sixty extracted human maxillary central incisors with one canal and closed apex were included in the study. Samples were randomly and equally divided into three groups (n = 20) according to the file systems used for preparation of the root canal. Teeth in the WO group were instrumented by WaveOne, while the PTN group were instrumented by ProTaper Next, and teeth samples in the PTG group were cleaned and shaped by ProTaper Gold. The mean apically extruded debris weight in grams was estimated using the modified Myers and Montgomery experimental model. Analysis of variance (ANOVA) test was used for the comparison of debris weight in three groups. Post hoc LSD test was applied for pairwise comparison of debris weight. The α value of significance was 0.05. The WO group had significantly lower mean debris weight than the PTN and PTG groups (p = 0.001). Post hoc pairwise comparison revealed that there was a statistically significant difference in mean debris weight between the WO group and PTN group (0.0215 vs. 0.0341, p = 0.001); and the WO group and PTG group (0.0215 vs. 0.0324, p = 0.003). Root canal preparations with different file systems were associated with apical extrusion of the debris from the root canal dentin layer. However, the WaveOne system resulted in a comparatively lower amount of apical debris layer extrusion than the ProTaper Next and ProTaper Gold rotary file systems.
Collapse
|
5
|
Ahmad MZ, Sadaf D, MacBain MM, Merdad KA. Effect of mode of rotation on apical extrusion of debris with four different single-file endodontic instrumentation systems: Systematic review and meta-analysis. AUST ENDOD J 2022; 48:202-218. [PMID: 35255170 DOI: 10.1111/aej.12612] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Revised: 12/20/2021] [Accepted: 02/13/2022] [Indexed: 01/19/2023]
Abstract
This systematic review and meta-analysis evaluated whether single-file endodontic instrumentation systems with the reciprocating type of motion are responsible for more debris extrusion than single-file endodontic instrumentation systems with the full rotational type of motion. Electronic and manual searches were performed following the recommendations of Preferred Reporting Items for Systematic Reviews and Meta-Analysis - PRISMA. We included studies comparing rotary (Neoniti and/ OneShape) versus reciprocating (WaveOne and/ Reciproc) systems. We evaluated the quality of studies and performed statistical analysis using R-Project software. Eight studies of high quality were included to perform the meta-analysis. Subgroup analysis was also done. The overall risk of bias was too low. In conclusion, single-file reciprocating systems tend to generate more extrusion of debris than single-file rotary systems.
Collapse
Affiliation(s)
- Muhammad Zubair Ahmad
- Restorative Dentistry Department, College of Dentistry in Ar Rass, Qassim University, Ar Rass, Saudi Arabia.,Nuffield Department of Primary Care Health Sciences, Centre for Evidence-Based Medicine, University of Oxford, Oxford, UK
| | - Durre Sadaf
- Nuffield Department of Primary Care Health Sciences, Centre for Evidence-Based Medicine, University of Oxford, Oxford, UK
| | - Marcy McCall MacBain
- Nuffield Department of Primary Care Health Sciences, Centre for Evidence-Based Medicine, University of Oxford, Oxford, UK
| | - Khalid A Merdad
- Department of Endodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| |
Collapse
|
6
|
Yamakami SA, Gallas JA, Petean IBF, Souza-Gabriel AE, Sousa-Neto M, Macedo AP, Palma-Dibb RG. Impact of Endodontic Kinematics on Stress Distribution During Root Canal Treatment: Analysis of Photoelastic Stress. J Endod 2021; 48:255-262. [PMID: 34699903 DOI: 10.1016/j.joen.2021.10.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 10/09/2021] [Accepted: 10/14/2021] [Indexed: 11/18/2022]
Abstract
INTRODUCTION Structural defects created by endodontic treatment are the most common cause of major dental failures. This study analyzed levels of stress produced by endodontic instruments during the root canal treatment by photoelastic analysis of stress. METHODS Twenty-four human premolars were randomly divided into 4 groups (n = 6) according to instrumentation protocol: ProTaper Next (GPT), One Shape (GOS), Wave One Gold (GWO), and TF Adaptive (GTF). The evaluation of the photoelastic model was performed at 4 dental zones: dental-crown region, cervical third of root, middle third of root, and apical third of root. Silicone molds were prepared (2 × 15 mm), and pinjets were used inside the root canals to fixate teeth. Photoelastic resin (2:1 ratio) was poured into the silicone molds to form photoelastic models. A transmission polariscope was used to analyze the positions of interest and recorded with a digital camera. Tardy's method was used to quantify the fringe order (n) and calculate the maximum stress value (τ) at each selected point. Data were analyzed with two-way analysis of variance, Tukey test (P < .05), fringe descriptive analysis. RESULTS All groups showed a significant increase in the level of stress created during biomechanical preparation of the root canals. In the quantitative analysis, there was no statistically significant difference among the groups (P > .05). In the qualitative analysis, GPT and GTF instruments achieved greater levels of stresses compared with GWO and GOS instruments. At the beginning of instrumentation, stresses were concentrated at the coronary level and the end of instrumentation at the middle and apical root level. CONCLUSIONS All endodontic systems resulted in accumulation of stress along the dental structure. Stress was found in different concentrations along the tooth and at different levels.
Collapse
Affiliation(s)
- Shelyn Akari Yamakami
- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Julia Adornes Gallas
- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Igor Bassi Ferreira Petean
- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Aline Evangelista Souza-Gabriel
- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Manoel Sousa-Neto
- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Ana Paula Macedo
- Department of Dental Materials and Prosthesis, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Regina Guenka Palma-Dibb
- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto, SP, Brazil.
| |
Collapse
|
7
|
Çanakçi BC, Er Ö, Genç Şen Ö, Süt N. The effect of two rotary and two reciprocating NiTi systems on postoperative pain after root canal retreatment on single-rooted incisor teeth: A randomized controlled trial. Int Endod J 2021; 54:2016-2024. [PMID: 34383324 DOI: 10.1111/iej.13609] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 08/07/2021] [Accepted: 08/10/2021] [Indexed: 01/07/2023]
Abstract
AIM This randomized clinical trial aimed to assess the effect of two rotary (ProTaper Retreatment + ProTaper Gold and Hyflex EDM) and two reciprocating (Reciproc Blue and WaveOne Gold) NiTi systems on postoperative pain after root canal retreatment on single-rooted incisor teeth. METHODOLOGY One hundred and eighty patients scheduled for root canal retreatment were randomly assigned to one of the four groups according to the NiTi system (ProTaper Retreatment + ProTaper Gold, Hyflex EDM, Reciproc Blue or WaveOne Gold) used for the removal of root canal fillings and further canal preparation. The working length was determined to be 1 mm shorter than the '0.0' mark of the apex locator. Root canals were filled with gutta-percha and an epoxy resin-based root canal sealer using a lateral compaction technique. The teeth were restored using a resin composite material. A single operator performed the retreatments in a single visit. The incidence and intensity of postoperative pain were rated on a numeric rating scale by patients 24, 48 and 72 h after retreatment. The number of analgesic tablets (400 mg Ibuprofen) taken by patients was also recorded. Data were analysed using the Mann-Whitney U, Wilcoxon and chi-square tests. RESULTS For the intensity of postoperative pain, the difference between the four groups was not significantly different (p > .05). No significant difference was found between the groups in terms of analgesic medication intake (p > .05). CONCLUSIONS The rotary and reciprocating NiTi systems tested in this study were associated with similar intensity of postoperative pain and intake of analgesics following root canal retreatment on single-rooted incisor teeth completed in one visit.
Collapse
Affiliation(s)
- Burhan Can Çanakçi
- Department of Endodontics, Faculty of Dentistry, Trakya University, Edirne, Turkey
| | - Özgür Er
- Department of Endodontics, Faculty of Dentistry, Trakya University, Edirne, Turkey
| | - Özgür Genç Şen
- Department of Endodontics, Faculty of Dentistry, Yüzüncü Yıl University, Van, Turkey
| | - Necdet Süt
- Department of Biostatistics, Medical Faculty, Trakya University, Edirne, Turkey
| |
Collapse
|
8
|
Hazar E, Özdemir O, Koçak M, Sağlam B, Koçak S. Apical debris extrusion of single-file systems in curved canals. ENDODONTOLOGY 2021. [DOI: 10.4103/endo.endo_105_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
9
|
Düzgün S, Topçuoğlu HS, Kahraman Ö. Evaluation of apically extruded debris during the canal preparation using new heat-treated nickel-titanium files in curved canals. AUST ENDOD J 2020; 47:54-58. [PMID: 33159482 DOI: 10.1111/aej.12459] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 10/01/2020] [Accepted: 10/21/2020] [Indexed: 11/29/2022]
Abstract
This study compared the amount of apically extruded debris associated with different heat-treated Ni-Ti rotary systems during the preparation of curved root canals of mandibular molars. Sixty extracted human mandibular molars were selected. EdgeFile, K3XF, OneCurve (OC) and ROTATE files were used to prepare both mesial canals of teeth. The initial weight of each Eppendorf tube to be used was calculated using an analytical balance prior to instrumentation. After instrumentation, the tubes were then stored for 5 days in an incubator at 70°C. Each tube was reweighed, and the weight of the dry extruded debris was established by subtracting the pre-instrumentation and post-instrumentation weight of the Eppendorf tubes for each group. All files caused apical extrusion of debris. There was no statistical difference between the ROTATE, EdgeFile, OC and K3XF systems (P > 0.05). All the heat-treated Ni-Ti rotary systems led to similar apical debris extrusion during the canal preparation.
Collapse
Affiliation(s)
- Salih Düzgün
- Department of Endodontics, Faculty of Dentistry, Erciyes University, Kayseri, Turkey
| | | | - Ömür Kahraman
- Department of Endodontics, Faculty of Dentistry, Erciyes University, Kayseri, Turkey
| |
Collapse
|
10
|
Gokturk H, Ozkocak I, Aydin U, Serefli ED. Effect of different chelating agents and their surface tension on the amount of apically extruded debris. J Dent Sci 2020; 16:195-200. [PMID: 33384797 PMCID: PMC7770288 DOI: 10.1016/j.jds.2020.06.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 06/14/2020] [Indexed: 12/01/2022] Open
Abstract
Background/purpose During root canal preparation apical extrusion is an undesirable situation that can cause postoperative complications. The aim of the present study is to evaluate the effect of the presence of different chelators in root canals during preparation on the amount of apically extruded debris and to investigate the effect of surface tension of irrigant on the apical extrusion. Materials and methods Ninety extracted mandibular incisor teeth were included. Prior to canal preparation, the teeth were mounted to Eppendorf tubes. Root canals of the samples were prepared with Reciproc instruments in the presence of different chelating agents (17% EDTA-liquid, 17% EDTA-gel, 7% maleic acid, 2.25% peracetic acid, 10% citric acid) and 5% NaOCl. Apically extruded debris was collected in Eppendorf tubes and weighted with an electronic balance. The surface tension of solutions was calculated with the ring method using a du Noüy ring digital tensiometer. The statistical analysis was performed with Tamhane's T2 test for apical extrusion and the Tukey for surface tension. The correlation between apical extrusion and surface tension was compared using Pearson's coefficient. Results The least amount of apically extruded debris was with EDTA-gel, peracetic acid and citric acid which were similar to each other. NaOCl had the highest surface tension whereas peracetic acid and EDTA-liquid had the lowest. There was no significant correlation exists between apical extrusion and surface tension. Conclusion The presence of EDTA-gel, citric acid and peracetic acid in root canals during preparation decreased the amount of apically extruded debris compared to other solutions. The investigated irrigation solutions have no significant effect on the amount of apical debris extrusion.
Collapse
Affiliation(s)
- Hakan Gokturk
- Department of Endodontics, Bolu Abant İzzet Baysal University, Bolu, Turkey
| | - Ismail Ozkocak
- Department of Endodontics, Bolu Abant İzzet Baysal University, Bolu, Turkey
| | - Ugur Aydin
- Department of Endodontics, Gaziantep University, Gaziantep, Turkey
| | | |
Collapse
|
11
|
KELEŞ A, Uzunoğlu Özyürek E, Uysal S, Tuncel B, Uyanik Ö, Nagaş E. Comparison of Apically Extruded Debris Associated with Different Nickel–Titanium Systems. CUMHURIYET DENTAL JOURNAL 2019. [DOI: 10.7126/cumudj.507866] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
12
|
Mendonça de Moura JD, Bueno CEDS, Fontana CE, Pelegrine RA. Extrusion of Debris from Curved Root Canals Instrumented up to Different Working Lengths Using Different Reciprocating Systems. J Endod 2019; 45:930-934. [PMID: 31109752 DOI: 10.1016/j.joen.2019.03.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Revised: 02/28/2019] [Accepted: 03/04/2019] [Indexed: 11/30/2022]
Abstract
INTRODUCTION The aim of this study was to evaluate the extrusion of debris associated with the use of the Reciproc (VDW GmbH, Munich, Germany) and WaveOne Gold (Dentsply Maillefer, Ballaigues, Switzerland) reciprocating systems in curved canals instrumented up to different working lengths (WLs). METHODS Sixty mesial roots of extracted mandibular first molars with mesiobuccal canals having curvatures between 10° and 20° and independent foramina were randomly distributed into 4 experimental groups (n = 15) according to WL and the instrumentation system used: RC0, Reciproc and WL at the apical foramen; RC1, Reciproc and WL at 1 mm short of the apical foramen; WOG0, WaveOne Gold and WL at the apical foramen; and WOG1, WaveOne Gold and WL at 1 mm short of the apical foramen. The canals were irrigated with double-distilled water throughout the preparation. Each root was fit into an Eppendorf tube to collect the debris extruded through the foramen during instrumentation. After instrumentation, the roots were removed from the tubes, and the weight of the debris was obtained by subtracting the initial weight of the tubes from their final weight. The data were submitted to the analysis of variance parametric test complemented by the Tukey test. RESULTS No statistically significant difference was observed between the 4 experimental groups regarding the amount of debris extruded (P > .05). CONCLUSIONS The 2 reciprocating systems tested were associated with similar amounts of apically extruded debris, regardless of the working length used in the instrumentation.
Collapse
Affiliation(s)
| | | | - Carlos Eduardo Fontana
- Department of Endodontics, School of Dentistry, Pontifical Catholic University of Campinas, Campinas, São Paulo, Brazil
| | - Rina Andrea Pelegrine
- Department of Endodontics, São Leopoldo Mandic Dental Research Center, Campinas, São Paulo, Brazil
| |
Collapse
|
13
|
Pedullà E, Ambu E, Rovai F, Chang SW, Campedelli F, Corsentino G, Rapisarda S, La Rosa GRM, Grandini S. Influence of proper or reciprocating optimum torque reverse kinematics on cyclic fatigue of four single files. ACTA ACUST UNITED AC 2019; 10:e12409. [PMID: 30848100 DOI: 10.1111/jicd.12409] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2018] [Accepted: 10/19/2018] [Indexed: 11/30/2022]
Abstract
AIM The aim of the present study was to evaluate the resistance to cyclic fatigue of heat-treated single files used in proper or in reciprocating optimum torque reverse motions. METHODS Ninety-six HyFlex electrical discharge machining (EDM), Reciproc R25 (Rec), WaveOne Primary (WO), and WaveOne Gold (WOG) Primary were used. Resistance to cyclic fatigue was determined by recording time to fracture in a stainless steel artificial canal. Differential scanning calorimetric analysis was performed. Data were analyzed by two-way analysis of variance and Bonferroni post-hoc tests at 0.05. RESULTS In both movements, HyFlex EDM showed higher time to fracture than other files (P < 0.0001). Rec showed higher time to fracture than WO (P < 0.0001), while WOG showed higher cyclic fatigue resistance than Rec and WO with both movements (P < 0.005). CONCLUSIONS Reciprocating optimum torque reverse motion improved significantly cyclic fatigue resistance of gold and controlled memory wire single files.
Collapse
Affiliation(s)
- Eugenio Pedullà
- Department of General Surgery and Surgical-Medical Specialties, University of Catania, Catania, Italy
| | - Emanuele Ambu
- Department of Endodontics and Restorative Dentistry, University of Siena, Siena, Italy
| | | | - Seok-Woo Chang
- Department of Conservative Dentistry, Kyung Hee University, Seoul, Korea
| | - Federico Campedelli
- Department of Endodontics and Restorative Dentistry, University of Siena, Siena, Italy
| | - Giacomo Corsentino
- Department of Endodontics and Restorative Dentistry, University of Siena, Siena, Italy
| | - Silvia Rapisarda
- Department of General Surgery and Surgical-Medical Specialties, University of Catania, Catania, Italy
| | - Giusy R M La Rosa
- Department of General Surgery and Surgical-Medical Specialties, University of Catania, Catania, Italy
| | - Simone Grandini
- Department of Endodontics and Restorative Dentistry, University of Siena, Siena, Italy
| |
Collapse
|
14
|
Keskin C, Sarıyılmaz E. Apically extruded debris and irrigants during root canal filling material removal using Reciproc Blue, WaveOne Gold, R-Endo and ProTaper Next systems. J Dent Res Dent Clin Dent Prospects 2019; 12:272-276. [PMID: 30774793 PMCID: PMC6368952 DOI: 10.15171/joddd.2018.042] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2017] [Accepted: 11/18/2018] [Indexed: 11/13/2022] Open
Abstract
Background. The present study aimed to compare the amount of apically extruded debris and irrigants produced by various nickel-titanium instruments.
Methods. A total of 100 single-rooted mandibular premolar teeth were root canal treated and prepared for agar gel model. The root canal fillings were removed using Reciproc Blue, ProTaper Next, R-Endo, WaveOne Gold systems or hand instrumentation. The mean weights of apically extruded materials were calculated. Data were statistically analyzed using one-way ANOVA and post hoc Bonferroni tests.
Results. Hand instrumentation resulted in significantly more debris and irrigants than other systems (P<0.05). The mean amount of apically extruded debris and irrigants produced by Reciproc Blue system was significantly greater than motordriven instruments (P<0.05). No significant difference was detected between ProTaper Next and WaveOne Gold systems (P>0.05), while they both produced significantly less apically extruded material than R-Endo system (P<0.05).
Conclusion. All the instruments caused apical extrusion. ProTaper Next and WaveOne Gold systems were associated with significantly less apical extrusion.
Collapse
Affiliation(s)
- Cangul Keskin
- Department of Endodontics, Faculty of Dentistry, Ondokuz Mayis University, Samsun, Turkey
| | - Evren Sarıyılmaz
- Department of Endodontics, Faculty of Dentistry, Ordu University Ordu, Turkey
| |
Collapse
|
15
|
Pedrinha VF, Brandão JMDS, Pessoa OF, Rodrigues PDA. Influence of File Motion on Shaping, Apical Debris Extrusion and Dentinal Defects: A Critical Review. Open Dent J 2018. [PMID: 29541265 PMCID: PMC5842382 DOI: 10.2174/1874210601812010189] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Advances in endodontics have enabled the evolution of file manufacturing processes, improving performance beyond that of conventional files. In the present study, systems manufactured using state of the art methods and possessing special properties related to NiTi alloys (i.e., CM-Wire, M-Wire and R-Phase) were selected. The aim of this review was to provide a detailed analysis of the literature about the relationship between recently introduced NiTi files with different movement kinematics and shaping ability, apical extrusion of debris and dentin defects in root canal preparations. From March 2016 to January 2017, electronic searches were conducted in the PubMed and SCOPUS databases for articles published since January 2010. In vitro studies performed on extracted human teeth and published in English were considered for this review. Based on the inclusion criteria, 71 papers were selected for the analysis of full-text copies. Specific analysis was performed on 45 articles describing the effects of reciprocating, continuous and adaptive movements on the WaveOne Gold, Reciproc, HyFlex CM and Twisted File Adaptive systems. A wide range of testing conditions and methodologies have been used to compare the systems. Due the controversies among the results, the characteristics of the files used, such as their design and alloys, appear to be inconsistent to determine the best approach.
Collapse
|
16
|
Dincer AN, Guneser MB, Arslan D. Apical extrusion of debris during root canal preparation using a novel nickel-titanium file system: WaveOne gold. J Conserv Dent 2018; 20:322-325. [PMID: 29386779 PMCID: PMC5767826 DOI: 10.4103/jcd.jcd_407_16] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Aim: This study was intended to evaluate the amount of apically extruded debris following root canal preparation with three different instrumentation systems. Materials and Methods: Sixty mandibular incisor teeth were selected and randomly divided into three groups (n = 20/group) according to the instrumentation system used: the ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), the Twisted File Adaptive (TFA; SybronEndo, Orange, CA, USA), and the WaveOne Gold (WOG; Dentsply Maillefer, Ballaigues, Switzerland). All apically extruded debris was collected and dried in preweighed glass vials. The mean weight of the apically extruded debris was obtained using a microbalance. The time for root canal preparation was also recorded. The data were analyzed using a one-way analysis of variance. Results: The mean weights of apically extruded debris were 0.00035 ± 0.00014 g (PTN); 0.00023 ± 0.0001 g (TFA); and 0.00019 ± 0.0001 g (WOG) (P < 0.01). The mean preparation time value was 301,13 ± 62.14 s (PTN); 234.27 ± 34.88 s (TFA); and 239.8 ± 58.6 s (WOG) (P < 0.05). Conclusions: The PTN system extruded more debris than the TFA and WOG systems. The TFA and WOG systems were faster than the PTN system.
Collapse
Affiliation(s)
- Asiye Nur Dincer
- Department of Endodontics, Faculty of Dentistry, Bezmialem Vakif University, Istanbul, Turkey
| | - Mehmet Burak Guneser
- Department of Endodontics, Faculty of Dentistry, Bezmialem Vakif University, Istanbul, Turkey
| | - Dilara Arslan
- Department of Endodontics, Faculty of Dentistry, Bezmialem Vakif University, Istanbul, Turkey
| |
Collapse
|
17
|
Zhang C, Liu J, Liu L. The influence of ProTaper and WaveOne on apically extruded debris: A systematic review and meta-analysis. J Conserv Dent 2018; 21:474-480. [PMID: 30294105 PMCID: PMC6161523 DOI: 10.4103/jcd.jcd_82_18] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Background: Apically extruded debris produced during root canal preparation can induce postoperative inflammation and subsequent failure of root canal treatment. Therefore, debris production must be reduced to improve the outcome of root canal treatment. Aim: This study aimed to provide a theoretical basis for the improvement of root canal treatment by comparing the difference in the amount of apically extruded debris produced during the root canal preparation of extracted human teeth with ProTaper Universal (PTU), ProTaper Next (PTN), and WaveOne (WO). Materials and Methods: On March 30, 2017, three researchers searched five electronic databases (PubMed/Medline, Cochrane, Science Direct Online, Embase, and Web of Science) with no time limitations. Only articles written in English were retrieved, and 150 articles were obtained. Then, the three researchers independently selected articles in accordance with previously established inclusion and exclusion criteria, and inconsistent results were discussed. Data were analyzed through meta-analysis for standardized mean difference (SMD). Results: Eight studies met the inclusion criteria and were subjected to qualitative analysis. Four articles showed that PTU produced higher amounts of apical debris than WO; two articles showed that PTU produced lower amounts of apical debris than WO; and three articles showed that PTN produced lower amounts of apical debris than WO. Moreover, one article demonstrated that PTU produced higher amounts of apical debris than PTN. A meta-analysis showed that PTU and WO did not produce significantly different amounts of apically extruded debris: SMD = −0.26, Z = 0.50 (P > 0.05). PTU produced lower amounts of apically extruded debris than WO: SMD = −4.98, Z = 2.79 (P < 0.05). However, results were significantly heterogeneous among all the included studies (I2= 97%). No significant difference was found between PTU and WO in the amounts of apically extruded debris: SMD = 0.47, Z = 1.06 (P > 0.05). Conclusion: Currently available evidence shows that PTN can produce lower amounts of apical debris than WO (P < 0.05). Moreover, the amounts of apically extruded debris produced by PTU and WO are not significantly different (P > 0.05). Nevertheless, given the limited number of studies reviewed, a definitive conclusion cannot be reached.
Collapse
Affiliation(s)
- Chen Zhang
- Department of Oral Medical, Affiliated Hospital of Qingdao University, Qingdao University, Qingdao, China
| | - Jun Liu
- Department of Orthodontics, Affiliated Hospital of Qingdao University, Qingdao, China
| | - Lingshuang Liu
- Department of Endodontics, Affiliated Hospital of Qingdao University, Qingdao, China.,Department of Oral Medical, Qingdao University, Qingdao, China
| |
Collapse
|
18
|
Abstract
In this Editor's Review, articles published in 2016 are organized by category and briefly summarized. We aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ Replacement, Recovery, and Regeneration. As the official journal of The International Federation for Artificial Organs, The International Faculty for Artificial Organs, the International Society for Mechanical Circulatory Support, the International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level." Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ Replacement, Recovery, and Regeneration from all over the world. We were pleased to publish our second Virtual Issue in April 2016 on "Tissue Engineering in Bone" by Professor Tsuyoshi Takato. Our first was published in 2011 titled "Intra-Aortic Balloon Pumping" by Dr. Ashraf Khir. Other peer-reviewed Special Issues this year included contributions from the 11th International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion edited by Dr. Akif Ündar and selections from the 23rd Congress of the International Society for Rotary Blood Pumps edited by Dr. Bojan Biocina. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide meaningful suggestions to the author's work whether eventually accepted or rejected. Without these excellent and dedicated reviewers the quality expected from such a journal could not be possible. We also express our special thanks to our Publisher, John Wiley & Sons for their expert attention and support in the production and marketing of Artificial Organs. We look forward to reporting further advances in the coming years.
Collapse
|
19
|
Pedullà E, Genovesi F, Rapisarda S, La Rosa GR, Grande NM, Plotino G, Adorno CG. Effects of 6 Single-File Systems on Dentinal Crack Formation. J Endod 2017; 43:456-461. [DOI: 10.1016/j.joen.2016.10.038] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2016] [Revised: 10/13/2016] [Accepted: 10/24/2016] [Indexed: 12/13/2022]
|