• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4616375)   Today's Articles (3184)   Subscriber (49396)
For: Kumar GP, Kabinejadian F, Liu J, Ho P, Leo HL, Cui F. Simulated Bench Testing to Evaluate the Mechanical Performance of New Carotid Stents. Artif Organs 2016;41:267-272. [PMID: 27357068 DOI: 10.1111/aor.12745] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2015] [Revised: 02/02/2016] [Accepted: 03/01/2016] [Indexed: 11/27/2022]
Number Cited by Other Article(s)
1
Vellaparambil R, Han WS, Di Giovanni P, Avril S. Potential of auxetic designs in endovascular aortic repair: A computational study of their mechanical performance. J Mech Behav Biomed Mater 2023;138:105644. [PMID: 36608533 DOI: 10.1016/j.jmbbm.2022.105644] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 12/01/2022] [Accepted: 12/25/2022] [Indexed: 12/27/2022]
2
Ong CW, Kumar GP, Zuo K, Koh LB, Charles CJ, Ho P, Leo HL, Cui F. A novel coating method to reduce membrane infolding through pre-crimping of covered stents – Computationaland experimental evaluation. Comput Biol Med 2022;145:105524. [DOI: 10.1016/j.compbiomed.2022.105524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 04/12/2022] [Accepted: 04/12/2022] [Indexed: 11/24/2022]
3
Yan S, Song C, Si Y, Zhao Y. Design of non-equal-strut stent hoops for structural optimization of thoracic aortic stent-grafts. MINIM INVASIV THER 2020;31:58-71. [PMID: 32233714 DOI: 10.1080/13645706.2020.1745849] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
4
Praveen Kumar G, Louis Commillus A, Cui F. A finite element simulation method to evaluate the crimpability of curved stents. Med Eng Phys 2019;74:162-165. [PMID: 31635945 DOI: 10.1016/j.medengphy.2019.07.017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Revised: 05/15/2019] [Accepted: 07/28/2019] [Indexed: 10/25/2022]
5
Malchesky PS. Artificial Organs 2017: A Year in Review. Artif Organs 2018. [PMID: 29516581 DOI: 10.1111/aor.13137] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
6
Jafary-Zadeh M, Praveen Kumar G, Branicio PS, Seifi M, Lewandowski JJ, Cui F. A Critical Review on Metallic Glasses as Structural Materials for Cardiovascular Stent Applications. J Funct Biomater 2018;9:E19. [PMID: 29495521 PMCID: PMC5872105 DOI: 10.3390/jfb9010019] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2017] [Revised: 02/05/2018] [Accepted: 02/22/2018] [Indexed: 01/20/2023]  Open
7
Praveen Kumar G, Jafary-Zadeh M, Cui F. Deployment of a Bulk Metallic Glass-Based Self-Expandable Stent in a Patient-Specific Descending Aorta. ACS Biomater Sci Eng 2016;2:1951-1958. [DOI: 10.1021/acsbiomaterials.6b00342] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA