1
|
Ichikawa K, Ichikawa K, Yamamoto N, Horai R. Flexural and Cell Adhesion Characteristic of Phakic Implantable Lenses. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1282. [PMID: 37512093 PMCID: PMC10385999 DOI: 10.3390/medicina59071282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 07/06/2023] [Accepted: 07/08/2023] [Indexed: 07/30/2023]
Abstract
Background and Objectives: In this study, we aimed to compare the physical properties of hole-implantable collamer lenses (H-ICLs) and implantable phakic contact lenses (IPCLs) and investigate their flexural and cell adhesion characteristics. Materials and Methods: Transverse compression load to achieve lens flexion and static Young's modulus were measured in H-ICLs and IPCLs using designated equipment. Load was measured both with and without restraining the optic section of the lenses. Adhesion of iHLEC-NY2 cells to the lens surfaces was examined using phase-contrast microscopy, and cell proliferation activity was evaluated using WST-8 assay. Results: The H-ICL showed a greater tendency for transverse compression load compared to IPCL, while the IPCL showed a higher Young's modulus with respect to the force exerted on the center of the anterior surface of the optic section. The joint between the optic section and haptic support in the IPCL was found to mitigate the effects of transverse compression load. Both lens types showed minimal cell adhesion. Conclusions: Our findings indicate that H-ICLs and IPCLs exhibit distinct physical properties and adhesive characteristics. The IPCL demonstrated higher Young's modulus and unique structural features, while the H-ICL required greater transverse compression load to achieve the flexion required to tuck the haptic supports into place behind the iris to fix the lens. The observed cell non-adhesive properties for both lens types are promising in terms of reducing complications related to cell adhesion. However, further investigation and long-term observation of IPCL are warranted to assess its stability and potential impact on the iris. These findings contribute to a better understanding of the performance and potential applications of H-ICLs and IPCLs in ophthalmology.
Collapse
Affiliation(s)
| | - Kei Ichikawa
- Chukyo Eye Clinic, Nagoya 456-0032, Aichi, Japan
- General Aoyama Hospital, Toyokawa 441-0103, Aichi, Japan
| | - Naoki Yamamoto
- Support Office for Bioresource Research, Translational Research Headquarters, Fujita Health University, Toyoake 470-1192, Aichi, Japan
| | - Rie Horai
- Chukyo Eye Clinic, Nagoya 456-0032, Aichi, Japan
| |
Collapse
|
2
|
Zaldivar R, Zaldivar R, Gordillo CH, Adamek P. Visual Acuity Improvement in Low, Moderate and High Myopia After Posterior-Chamber Phakic Implantable Collamer Lens Surgery in a Large Patient Cohort. Clin Ophthalmol 2023; 17:1179-1185. [PMID: 37096208 PMCID: PMC10122501 DOI: 10.2147/opth.s407492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Accepted: 04/11/2023] [Indexed: 04/26/2023] Open
Abstract
Purpose To compare best-corrected visual acuity (BCVA) before and after implantable collamer lens (ICL) surgery in patients with low, moderate and high myopia. Methods A single-centre, prospective, registry-based study involving patients with myopia who received ICLs between October 2018 and August 2020. The study population was divided into three groups of subjects with low (from 0 to -6 D), moderate (-6 to -10 D) and high myopia (more than -10 D). We analysed uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), spherical equivalent (SE), differences between BCVA pre- and 1-month postoperative, and line gain in BCVA 1 month after surgery. Results A total of 770 eyes belonging to 473 patients were surgically intervened during the study period, of which 692 eyes completed 1 month of postoperative follow-up and were included in the study population. At 1-month follow-up, 478 eyes (69%) achieved a BCVA of 20/20, 599 (87%) obtained 20/25 or better, and 663 (96%) had a BCVA of 20/40 or better. We identified a significant improvement in BCVA (baseline 0.15±0.2 logMAR vs follow-up 0.07±0.2 logMAR, p<0.0001) and a significant reduction in SE (baseline -9.23±4.1 D, vs follow-up -0.21±0.8 D, p<0.0001), with a significant relationship between preoperative SE and line gain (r = -0.46, p<0.0001). We identified a significantly higher line gain among eyes with higher degrees of myopia (low myopia 0.22±0.69 lines compared to moderate myopia 0.56±1.1 lines and high myopia 1.51±1.9 lines, p<0.0001). Notably, 99.6% of eyes with a high grade of myopia achieved improvement to a low degree (less than -6 D) at follow-up. The safety and efficacy indexes were 0.083±0.1 and -0.001±0.1, respectively. Conclusion In this large patient cohort, ICL surgery was related to a significant line gain in BCVA, particularly among eyes with higher degrees of myopia.
Collapse
Affiliation(s)
- Roger Zaldivar
- Surgery Department, Instituto Zaldivar, Mendoza, Argentina
- Correspondence: Roger Zaldivar, Instituto Zaldivar, Av. Emilio Civit 701, Mendoza, Argentina, Email
| | | | | | - Pablo Adamek
- Surgery Department, Instituto Zaldivar, Mendoza, Argentina
| |
Collapse
|
3
|
Devi P, Kumar P, Marella BL, Bharadwaj SR. Impact of Degraded Optics on Monocular and Binocular Vision: Lessons from Recent Advances in Highly-Aberrated Eyes. Semin Ophthalmol 2022; 37:869-886. [PMID: 35786147 DOI: 10.1080/08820538.2022.2094711] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
PURPOSE Optical imperfections of the eye, characterized by higher-order wavefront aberrations, are exaggerated in corneal disease (e.g., keratoconus) and iatrogeny (e.g., keratorefractive surgery for myopia correction, keratoplasty for optical clarity restoration). This article reviews the recent advances on this topic for a comprehensive understanding of how optical degradations in disease models impact retinal image quality and monocular and binocular visual performance. METHODS Published literature over the last decade on retinal image quality and/or monocular and binocular visual functions with corneal irregularity was reviewed based on their relevance to the current topic, study population and strength of study design. The literature was summarized into four themes: 1) wavefront errors and retinal image quality of highly aberrated eyes, 2) monocular and binocular vision loss consequent to degraded optics and visual strategies to optimize performance, 3) impact of optical correction modalities on visual performance and 4) implications for clinical management of patients. RESULTS Across the 46 articles reviewed, the results clearly indicated that an increase in higher-order aberrations across these conditions had a significant negative impact on the patient's retinal image quality, and monocular and binocular visual functions. Interocular differences in retinal image quality deteriorated visual performance more than an overall worsening of image quality bilaterally. Minimizing optical degradation using rigid contact lenses and adaptive optics technology significantly improves retinal image quality and monocular and binocular vision, but performance remains sub-optimal relative to age-similar healthy controls. CONCLUSION Corneal disease and iatrogeny are useful models to understand the impact of optical degradation on retinal image quality and visual performance. Clinical management will greatly benefit from equalizing retinal image quality of both eyes of these patients. Future studies that deepen our understanding of the structure-function relation in these conditions are desirable for advancing vision science in this area and for developing novel clinical management strategies.
Collapse
Affiliation(s)
- Preetirupa Devi
- Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India.,Prof Brien Holden Eye Research Centre, L V Prasad Eye Institute, Hyderabad, India.,School of Health Sciences, Division of Optometry and Visual Sciences, City, University of London, London, UK
| | - Preetam Kumar
- Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India.,Prof Brien Holden Eye Research Centre, L V Prasad Eye Institute, Hyderabad, India.,School of Health Sciences, Division of Optometry and Visual Sciences, City, University of London, London, UK
| | - Bhagya Lakshmi Marella
- Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India.,Prof Brien Holden Eye Research Centre, L V Prasad Eye Institute, Hyderabad, India.,School of Health Sciences, Division of Optometry and Visual Sciences, City, University of London, London, UK
| | - Shrikant R Bharadwaj
- Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India.,Prof Brien Holden Eye Research Centre, L V Prasad Eye Institute, Hyderabad, India
| |
Collapse
|
4
|
Corneal stromal repair and regeneration. Prog Retin Eye Res 2022; 91:101090. [DOI: 10.1016/j.preteyeres.2022.101090] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2022] [Revised: 05/17/2022] [Accepted: 05/19/2022] [Indexed: 01/02/2023]
|
5
|
Sarkar S, Devi P, Vaddavalli PK, Reddy JC, Bharadwaj SR. Differences in Image Quality after Three Laser Keratorefractive Procedures for Myopia. Optom Vis Sci 2022; 99:137-149. [PMID: 34974458 DOI: 10.1097/opx.0000000000001850] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE Psychophysical estimates of spatial and depth vision have been shown to be better after bilateral ReLEx small-incision lenticule extraction (SMILE) refractive surgery for myopia, relative to photorefractive keratectomy (PRK) and femtosecond laser-assisted in situ keratomileusis (FS-LASIK). The present study provides the optical basis for these findings using computational image quality analysis. PURPOSE This study aimed to compare longitudinal changes in higher-order wavefront aberrations and image quality before and after bilateral PRK, FS-LASIK, and SMILE refractive procedures for correcting myopia. METHODS Wavefront aberrations and image quality of both the eyes of 106 subjects (n = 40 for FS-LASIK and SMILE and n = 26 for PRK) were determined pre-operatively and at 1-week, 1-month, 3-month, and 6-month post-operative intervals using computational through-focus analysis for a 6-mm pupil diameter. Image quality was quantified in terms of its peak value and its interocular difference, residual defocus that was needed to achieve peak image quality (best focus), and the depth of focus. RESULTS The increase in root mean squared deviations of higher-order aberrations post-operatively was lesser after SMILE (1-month visit median [25th to 75th interquartile range], 0.34 μm (0.28 to 0.39 μm]) than after PRK (0.80 μm [0.74 to 0.87 μm]) and FS-LASIK (0.74 μm [0.59 to 0.83 μm]; P ≤ .001), all relative to pre-operative values (0.20 μm [0.15 to 0.30 μm]). The peak image quality dropped and its interocular difference increased, best focus shifted myopically by 0.5 to 0.75 D, and depth of focus widened significantly after PRK and FS-LASIK surgeries, all relative to pre-operative values (P < .001). All these changes were negligible but statistically significant in a minority of instances after SMILE surgery (P ≥ .01). CONCLUSIONS Although all three refractive surgeries correct myopia, the image quality and its similarity between eyes are better and closer to pre-operative values after SMILE, compared with FS-LASIK and PRK. These results can be explained from the underlying increase in higher-order wavefront aberrations experienced by the eye post-operatively.
Collapse
Affiliation(s)
| | | | | | - Jagadesh C Reddy
- The Cornea Institute, L V Prasad Eye Institute, Hyderabad, Telangana, India
| | | |
Collapse
|
6
|
Fakhraie G, Vahedian Z, Zarei R, Eslami Y, Tabatabaei SM, Hadi A, Ghods S, Fakhraie A. Intraocular pressure trend following myopic photorefractive keratectomy. Int Ophthalmol 2022; 42:2313-2321. [DOI: 10.1007/s10792-022-02228-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 01/09/2022] [Indexed: 10/19/2022]
|
7
|
Menon J. Refractive Corneal surgeries: A Review. KERALA JOURNAL OF OPHTHALMOLOGY 2022. [DOI: 10.4103/kjo.kjo_21_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
8
|
Comparison of the effect of removing bandage contact lens on the days 3 and 5 following photorefractive keratectomy. Int Ophthalmol 2021; 42:575-580. [PMID: 34635956 DOI: 10.1007/s10792-021-02029-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Accepted: 09/22/2021] [Indexed: 10/20/2022]
Abstract
AIM To compare the outcomes of removing bandage contact lens (BCL) on days 3 and 5 after photorefractive keratectomy (PRK). METHODS One hundred patients who underwent PRK (a total of 200 eyes) were enrolled in the present study. The subjects were assigned to two groups. Group 1 consisted of the right eyes of subjects and bandage contact lenses removal were on the 3rd day; Group 2 consisted of the fellow eyes of same subjects and removed bandage contact lenses on the 5th day after PRK. Then, data obtained from both groups were compared. To evaluate complications, the subjects underwent a slit-lamp examination in all visits. RESULTS Filamentary keratitis was observed in one eye in both groups. The frequency of haze was higher in group 1; however, it was not significant between the two groups. Using mixed model analysis, significant differences were observed in the rate of complications as well as pain and eye discomfort scores between the groups (P < 0.05). No major complication was reported. CONCLUSION Majority of post-PRK corneal epithelial defect is healed on day 3. However, keeping BCL for 5 days postoperatively instead of the three days produces a slightly lower rate of total complication.
Collapse
|
9
|
Liu YC, Jung ASJ, Chin JY, Yang LWY, Mehta JS. Cross-sectional Study on Corneal Denervation in Contralateral Eyes Following SMILE Versus LASIK. J Refract Surg 2021; 36:653-660. [PMID: 33034357 DOI: 10.3928/1081597x-20200730-01] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Accepted: 07/21/2020] [Indexed: 01/16/2023]
Abstract
PURPOSE To compare long-term corneal nerve status following small incision lenticule extraction (SMILE) versus laser in situ keratomileusis (LASIK). METHODS Twenty-four patients were randomized to receive SMILE in one eye and LASIK in the other eye. In vivo confocal microscopy examination and dry eye assessments were performed at a mean of 4.1 years postoperatively. The patients were further divided into two groups based on the mean assessment time: 2.7 years postoperatively (2.7 years group) and 5.5 years postoperatively (5.5 years group). Another 6 age-matched normal patients were recruited. RESULTS At 4.1 years, LASIK eyes had significantly less corneal nerve fiber density (CNFD), corneal nerve branch density (CNBD), corneal nerve fiber length (CNFL), and corneal total branch density and significantly more nerves with beading than SMILE eyes. The CNFD, CNBD, CNFL, and number of nerves with sprouting were significantly higher in the 5.5 years group than in the 2.7 years group, in both types of surgery, suggesting persistent nerve regeneration. The CNBD and CNFD in the 5.5 years group, regardless of surgical types, were significantly lower than those in the control group, indicating the nerve status had not recovered to normal ranges even at 5.5 years. High myopic treatment resulted in significantly reduced CNFD with LASIK but not with SMILE. There were no significant differences in the dry eye parameters between the two procedures at 4.1 years postoperatively. CONCLUSIONS The impact on corneal nerves following refractive surgery is long-lasting. SMILE had better nerve preservation and regeneration than LASIK, but neither procedure had recovered nerve status to normal levels even at 5.5 years. [J Refract Surg. 2020;36(10):653-660.].
Collapse
|
10
|
Visual image quality after small-incision lenticule extraction compared with that of spectacles and contact lenses. J Cataract Refract Surg 2021; 47:731-740. [PMID: 33181632 DOI: 10.1097/j.jcrs.0000000000000501] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Accepted: 10/28/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE To assess the influence of small-incision lenticule extraction (SMILE) for high myopia on the visual image quality assessed by the logarithm of the visual Strehl ratio (logVSX) and put this into a clinical context by pairwise comparing the logVSX of postoperative eyes with those of myopic controls wearing spectacles and/or contact lenses. SETTING University hospital. DESIGN Prospective and cross-sectional clinical study. METHODS Patients with a myopic spherical equivalent of at least 6.00 diopters treated with SMILE aimed at emmetropia and correspondingly myopic controls corrected with spectacles and/or contact lenses were included. The logVSX calculation was divided into habitual logVSX based on the wavefront aberration measurement directly and optimal logVSX calculated in a theoretical through-focus experiment to obtain the best-achievable logVSX. RESULTS A total of 117 eyes of 61 patients and 64 eyes of 34 myopic controls were included. SMILE did not affect the habitual logVSX but worsened the optimal logVSX (P < .001). The postoperative habitual logVSX was statistically significantly worse compared with contact lenses (P = .002). The postoperative optimal logVSX was significantly worse compared with both spectacles (P < .01) and contact lenses (P = .003). There was no statistically significant difference in habitual or optimal logVSX between spectacles and contact lenses. CONCLUSIONS SMILE for high myopia does not affect the habitual logVSX but decreases the optimal logVSX slightly. The postoperative habitual logVSX is worse than for contact lenses but not spectacles, and the postoperative optimal logVSX is worse than for both contact lenses and spectacles. There is no statistically significant difference in either habitual or optimal logVSX between spectacles and contact lenses.
Collapse
|
11
|
Lanza M, De Rosa L, Sbordone S, Boccia R, Gironi Carnevale UA, Simonelli F. Analysis of Corneal Distortion after Myopic PRK. J Clin Med 2020; 10:jcm10010082. [PMID: 33379378 PMCID: PMC7794860 DOI: 10.3390/jcm10010082] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 12/14/2020] [Accepted: 12/24/2020] [Indexed: 01/22/2023] Open
Abstract
The purpose of the study is to evaluate the corneal biomechanical properties (CBP) and their behaviors after myopic refractive surgery both with Ocular Response Analyzer (ORA) and Corvis ST (CST). This retrospective study included 145 eyes of 145 patients with a mean age of 33.13 ± 9.24 years, who underwent myopic photorefractive keratectomy (PRK) for a refractive defect, measured as spherical equivalent, of mean −4.69 ± 2.04 D and have been evaluated before surgery and at 1, 3 and 6 months follow-up. Corneal hysteresis (CH) and corneal resistance factor (CRF) values significantly decreased after 1 month and remained statistically stable during further follow-ups. CST parameters had a different evolution: only second applanation time (AT2) differences showed a significant variation after 1 month that did not statistically change over time. Highest concavity deformation amplitude (HCDA), highest concavity peak distance (HCPD), first applanation time (AT1) and velocity (AV1) showed continuous significant differences both after 3 and after 6 months. This study suggests that after central surface ablation surgery, such as myopic PRK, corneal shape is remodeling, and its deformation parameters are going to change even at 6 months follow-up. This indicates that it should be important to evaluate refractive surgery patients during a longer follow-up because this could allow earlier diagnosis and better management of late-onset complications.
Collapse
|
12
|
Ang M, Gatinel D, Reinstein DZ, Mertens E, Alió Del Barrio JL, Alió JL. Refractive surgery beyond 2020. Eye (Lond) 2020; 35:362-382. [PMID: 32709958 DOI: 10.1038/s41433-020-1096-5] [Citation(s) in RCA: 85] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Revised: 05/19/2020] [Accepted: 07/08/2020] [Indexed: 02/07/2023] Open
Abstract
Refractive surgery refers to any procedure that corrects or minimizes refractive errors. Today, refractive surgery has evolved beyond the traditional laser refractive surgery, embodied by the popular laser in situ keratomileusis or 'LASIK'. New keratorefractive techniques such as small incision lenticule extraction (SMILE) avoids corneal flap creation and uses a single laser device, while advances in surface ablation techniques have seen a resurgence in its popularity. Presbyopic treatment options have also expanded to include new ablation profiles, intracorneal implants, and phakic intraocular implants. With the improved safety and efficacy of refractive lens exchange, a wider variety of intraocular lens implants with advanced optics provide more options for refractive correction in carefully selected patients. In this review, we also discuss possible developments in refractive surgery beyond 2020, such as preoperative evaluation of refractive patients using machine learning and artificial intelligence, potential use of stromal lenticules harvested from SMILE for presbyopic treatments, and various advances in intraocular lens implants that may provide a closer to 'physiological correction' of refractive errors.
Collapse
Affiliation(s)
- Marcus Ang
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore. .,Department of Ophthalmology and Visual Science, Duke-NUS Graduate Medical School, Singapore, Singapore.
| | | | - Dan Z Reinstein
- London Vision Clinic, London, UK.,Department of Ophthalmology, Columbia University Medical Center, New York, NY, USA.,Sorbonne Université, Paris, France.,Biomedical Science Research Institute, Ulster University, Belfast, UK
| | - Erik Mertens
- Medipolis-Antwerp Private Clinic, Antwerp, Belgium
| | - Jorge L Alió Del Barrio
- Division of Ophthalmology, School of Medicine, Universidad Miguel Hernández, Alicante, Spain.,Cornea, Cataract and Refractive Surgery Unit, Vissum (Miranza Group), Alicante, Spain
| | - Jorge L Alió
- Division of Ophthalmology, School of Medicine, Universidad Miguel Hernández, Alicante, Spain.,Cornea, Cataract and Refractive Surgery Unit, Vissum (Miranza Group), Alicante, Spain
| |
Collapse
|
13
|
Sedaghat MR, Momeni-Moghaddam H, Gazanchian M, Reinstein DZ, Archer TJ, Randleman JB, Hosseini SR, Nouri-Hosseini G. Corneal Epithelial Thickness Mapping After Photorefractive Keratectomy for Myopia. J Refract Surg 2020; 35:632-641. [PMID: 31610004 DOI: 10.3928/1081597x-20190826-03] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Accepted: 08/26/2019] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the longitudinal changes in epithelial thickness after photorefractive keratectomy (PRK) and correlate these with refractive changes. METHODS This prospective study included 52 eyes of 52 candidates for myopic PRK. Along with standard ophthalmic examinations, corneal epithelial thickness mapping by anterior segment optical coherence tomography was performed. Epithelial thickness maps of 9-mm diameter were divided into 25 sectors, including a central 2-mm zone and eight octants within para-central (2 to 5 mm), midperipheral (5 to 7 mm), and peripheral (7 to 9 mm) annular zones. All PRK treatments were performed using the Technolas Teneo 317 model 2 excimer laser (Bausch & Lomb, Rochester, NY) and an aspheric profile with a 6-mm diameter optical zone. Follow-up was at 1, 3, and 6 months. RESULTS Repeated thickness measures before and after PRK at different follow-up times showed a significant difference in thickness separately in various zones (P < .001). A significant decrease in thickness was seen 1 month after PRK in all zones. Afterward, epithelial thickening continued in all zones and reached the preoperative thickness in the midperipheral and peripheral zones 6 months later, whereas the thickness in the central 5-mm zone was significantly thicker than before surgery. There was also a significant correlation between changes in spherical equivalent and epithelial thickness from before to 6 months postoperatively in the paracentral and peripheral zones. CONCLUSIONS There was a marked decrease in the epithelial thickening pattern at 1 month after PRK, with gradual thickening at 3 and 6 months. Changes in epithelial thickness and spherical equivalent were significant only for the para-central peripheral zone. [J Refract Surg. 2019;35(10):632-641.].
Collapse
|
14
|
Zarei-Ghanavati S, Eslampour A, Shokouhirad S, Mazloum J, Yousefian A, Hassanzadeh S, Bakhtiari E, Eghbali P. The effect of eye dominancy on patients' cooperation and perceived pain during photorefractive keratectomy. J Curr Ophthalmol 2019; 31:373-376. [PMID: 31844785 PMCID: PMC6896458 DOI: 10.1016/j.joco.2019.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Revised: 06/19/2019] [Accepted: 07/03/2019] [Indexed: 11/26/2022] Open
Abstract
PURPOSE To find a possible association between patients' cooperation, perceived pain, and ocular dominance in patients who undergo photorefractive keratectomy (PRK). METHODS One hundred-one eligible candidates for PRK refractive surgery were recruited. Preoperative exams were performed for all patients, and the dominant eye was specified. The surgeon was unaware about which eye was dominant. After surgery, the surgeon completed a cooperation score form for each patient. Ocular cyclotorsion, cooperation, and perceived pain scores were compared between the first-second eye surgeries and between dominant-non-dominant eyes surgeries. RESULTS The dominant eye was the right eye in 68 patients and the left eye in 33 patients. First, eye surgery was performed on the dominant eye in 56 patients and on the non-dominant eye in 45 patients. Cooperation score and perceived pain were not significantly different between the first and second eye surgeries (P = 0.902 and P = 0.223, respectively), but cyclotorsion was more in the second eye (P = 0.031). Cooperation score, pain score, and cyclotorsion were not significantly different between dominant and non-dominant eye surgeries (P = 0.538, P = 0.581, and P = 0.193, respectively). Also, there was no correlation between cooperation score and duration of the surgery for the first or second eye (P = 0.12 and P = 0.78). CONCLUSION During PRK surgery, the patients' cooperation and perceived pain did not seem to be associated with eye laterality or dominancy.
Collapse
Affiliation(s)
| | - Alireza Eslampour
- Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Saeed Shokouhirad
- Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Javad Mazloum
- Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Ali Yousefian
- Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Samira Hassanzadeh
- Student Research Committee, Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Elham Bakhtiari
- Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Pardis Eghbali
- Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| |
Collapse
|
15
|
Tsatsos M, Athanasiadis I, MacGregor C, Aristeidou A, Moschos MM, Ziakas N. Combined photorefractive keratectomy and cross-linking. Pushing the limits. Taiwan J Ophthalmol 2019; 9:206-209. [PMID: 31572660 PMCID: PMC6759553 DOI: 10.4103/tjo.tjo_7_19] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2019] [Accepted: 06/25/2019] [Indexed: 11/18/2022] Open
Abstract
Correction of refractive error through laser-assisted means has soared in popularity in recent years, allowing it to become an increasingly routine surgical procedure. Technique refinement and adjustments resulted in laser-assisted refractive surgery to be combined with treatments such as collagen cross linking (CXL). This has broadened safety parameters and widened the treatment boundaries. Laser correction combined with CXL has been advocated in the treatment of high refractive errors as a safe option for full refractive correction while increasing corneal biomechanical stability. We present a complicated case where a young female patient with a preoperative best-corrected visual acuity (BCVA) of 20/20 in each eye was fully corrected by excimer laser followed by CXL. Factors potentially leading to inflammation, such as ocular surface disease, in addition to laser treatment and CXL, resulted in persistent epithelial defect followed by corneal melt and subsequent thinning. After the treatment, the patient relies on rigid gas-permeable contact lenses, achieving a BCVA of 20/25 and 20/23 in the right eye and left eye, respectively.
Collapse
Affiliation(s)
- Michael Tsatsos
- Department of Ophthalmology, Aristotle University of Thessaloniki, Greece.,Modern Ophthalmic Practice, Thessaloniki, Greece
| | - Ioannis Athanasiadis
- Department of Ophthalmology, Aristotle University of Thessaloniki, Greece.,Modern Ophthalmic Practice, Thessaloniki, Greece
| | | | | | | | - Nikolaos Ziakas
- Department of Ophthalmology, Aristotle University of Thessaloniki, Greece
| |
Collapse
|
16
|
Fernández J, Rodríguez-Vallejo M, Martínez J, Tauste A, Hueso E, Piñero DP. Confounding sizing in posterior chamber phakic lens selection due to white-to-white measurement bias. Indian J Ophthalmol 2019; 67:344-349. [PMID: 30777951 PMCID: PMC6407395 DOI: 10.4103/ijo.ijo_613_18] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Purpose: To assess the agreement in the white-to-white (WTW) measurement with two different devices, the reproducibility and the probability of confusing sizing (PCS) in selecting a different implantable collamer lens (ICL). Study Design: Retrospective observational case series. Methods: Images of 192 eyes were captured with both devices. The WTW was measured automatically (OA) and manually (OM) with the Orbscan and Keratograph (KA and KM) by one examiner who repeated a total of four measures. A second examiner conducted a single manual measure for each device over the same image. The ICL sizing was computed for each measure of WTW and the PCS was calculated as the percentage of cases for which the confronted or repeated measure resulted in a different size of the ICL. The critical WTWs with highest PCS were identified. Results: KM overestimated the WTW versus OM in 0.13 ± 0.18 mm (P < 0.001) but not in the automated method comparison, 0.01 ± 0.19 mm (P = 0.58). Inter-examiner reproducibility (R) was higher with OM than with KM, and the intra-examiner R decreased with the average of two measures in both cases. The PCS was higher with the increase of mean differences, the limits of agreement (LoAs), and R. WTWs from 11.1 to 11.2 mm, 11.6 to 11.7 mm, and 12.3 to 12.4 mm resulted in higher PCS. Conclusion: The mean difference is not enough to apply conversions between devices and the LoAs and R should be considered. Special attention should be taken for WTWs with higher PCS.
Collapse
Affiliation(s)
- JoaquIn Fernández
- Department of Ophthalmology (Qvision), Vithas Virgen del Mar Hospital, 04120; Department of Ophthalmology, Torrecárdenas Hospital Complex, 04009, Almería, Spain
| | | | - Javier Martínez
- Department of Ophthalmology (Qvision), Vithas Virgen del Mar Hospital, 04120, Almería, Spain
| | - Ana Tauste
- Department of Ophthalmology (Qvision), Vithas Virgen del Mar Hospital, 04120, Almería, Spain
| | - Elisa Hueso
- Department of Ophthalmology (Qvision), Vithas Virgen del Mar Hospital, 04120, Almería, Spain
| | - David P Piñero
- Department of Optics, Pharmacology and Anatomy, University of Alicante; Department of Ophthalmology (IMQO-Oftalmar), Vithas Medimar International Hospital, Alicante, Spain
| |
Collapse
|
17
|
Kim TI, Alió Del Barrio JL, Wilkins M, Cochener B, Ang M. Refractive surgery. Lancet 2019; 393:2085-2098. [PMID: 31106754 DOI: 10.1016/s0140-6736(18)33209-4] [Citation(s) in RCA: 197] [Impact Index Per Article: 32.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Revised: 11/29/2018] [Accepted: 12/11/2018] [Indexed: 01/19/2023]
Abstract
Refractive surgery has evolved beyond laser refractive techniques over the past decade. Laser refractive surgery procedures (such as laser in-situ keratomileusis), surface ablation techniques (such as laser epithelial keratomileusis), and photorefractive keratectomy have now been established as fairly safe procedures that produce excellent visual outcomes for patients with low-to-moderate amounts of ametropia. Additionally, a broader selection of options are now available to treat a wider range of refractive errors. Small incision lenticule extraction uses a femtosecond laser to shape a refractive lenticule, which is removed through a small wound. The potential advantages of this procedure include greater tectonic strength and less dry eye. In the future, intracorneal implants could be used to treat hyperopia or presbyopia. Phakic intraocular implants and refractive lens exchange might be useful options in carefully selected patients for correcting high degrees of ametropia. Thus, physicians are now able to provide patients with the appropriate refractive corrective option based on the individual's risk-benefit profile.
Collapse
Affiliation(s)
- Tae-Im Kim
- Department of Ophthalmology, The Institute of Vision Research, Yonsei University College of Medicine, Seoul, South Korea
| | - Jorge L Alió Del Barrio
- Cornea, Cataract and Refractive Surgery Unit, Research & Development Department VISSUM Innovation Alicante, Alicante, Spain; Division of Ophthalmology, School of Medicine, Universidad Miguel Hernández, Alicante, Spain
| | - Mark Wilkins
- Department of Ophthalmology, Moorfields Eye Hospital, London, UK
| | - Beatrice Cochener
- Department of Ophthalmology, University Hospital Morvan, Brest, France
| | - Marcus Ang
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore; Department of Ophthalmology and Visual Science, Duke-NUS Graduate Medical School, Singapore.
| |
Collapse
|
18
|
Steinwender G, Shajari M, Mayer WJ, Kook D, Ardjomand N, Vidic B, Kohnen T, Wedrich A. Impact of a Displaced Corneal Apex in Small Incision Lenticule Extraction. J Refract Surg 2018; 34:460-465. [PMID: 30001449 DOI: 10.3928/1081597x-20180514-01] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Accepted: 04/20/2018] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the possible impact of a displaced corneal apex (point of maximum curvature) on visual results and tomographic parameters after small incision lenticule extraction (SMILE). METHODS In this retrospective evaluation, eyes with uncomplicated SMILE for myopia correction were classified in two groups based on their preoperative distance between the corneal apex and corneal vertex (corneal intercept with the patient's line of sight) of 1 mm or greater (large A-V distance) or less than 1 mm (small A-V distance). All surgeries were performed during the early learning curve of two surgeons. Visual outcome parameters included uncorrected (UDVA) and corrected (CDVA) distance visual acuity, manifest refractive spherical equivalent (MRSE), and refractive astigmatism 3 months postoperatively. Scheimpflug-derived tomographic outcome parameters included mean keratometry value, root mean square higher order aberrations (RMS HOAs), and optical zone decentration. RESULTS The study comprised 94 eyes of 48 patients: 44 eyes in the large A-V distance group and 50 eyes in the small A-V distance group. Preoperative and postoperative RMS HOAs were significantly higher in the large A-V distance group than in the small A-V distance group (P = .002 and .008, respectively). Postoperative CDVA was significantly better in the small A-V distance group (P = .014). There were no statistically significant differences in postoperative UDVA, MRSE, refractive astigmatism, mean keratometry value, and optical zone decentration. CONCLUSIONS After SMILE, CDVA was significantly worse in eyes with a preoperatively displaced corneal apex compared to eyes with a more central corneal apex. However, good visual results were achieved in both groups. [J Refract Surg. 2018;34(7):460-465.].
Collapse
|
19
|
Pavkova Z, Kacerovska J, Kacerovsky M. Comparison of the efficiency of femtoLASIK and ReLEx SMILE in terms of dioptric error reduction. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 2018; 162:329-334. [PMID: 29936526 DOI: 10.5507/bp.2018.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND AND AIMS Refractive eye surgery is a rapidly expanding field of ophthalmology and corneal surgery is undergoing constant development leading to less invasive technologies. The goal of this study was to compare the most common femtoLASIK surgery with the newer ReLEx SMILE surgery which is gentler to the cornea. The comparison was made in terms of dioptric error reduction. METHODS The studied cohort of patients consisted of two major groups: 30 patients who underwent femtoLASIK surgery and 30 who underwent ReLEx SMILE surgery. -30 patients, 60 eyes. All patients were aged 18-45 years with moderate myopia or astigmatism ranging from -3.25 to -6.0 spherical diopters and from 0 to -1.0 cylindrical diopters. In all, the best corrected visual acuity measured prior to surgery was 1.0. Pachymetry was not comparable because each surgical method was performed at a different time point and the introduction of an innovative method into practice led to a change in selection criteria. RESULTS During postsurgical check-ups, the ReLEx SMILE method (0.74) led to lower values of non-corrected visual acuity compared to the femtoLASIK method (0.88), (P<0.001). However, the results changed at the one-year post-surgery check-up, when ReLEX SMILE patients achieved non-corrected visual acuity of 0.97 compared to femtoLASIK patients, who scored 0.83, (P=0.007). Based on data analysis from the automatic refractometer, the average spherical diopters of the femtoLASIK (-0.32 D) were higher than those of the ReLEx SMILE (-0.07 D), (P<0.001). The results for the cylindrical diopters were also significant, (P=0.021). When we compared the spherical equivalent one year after surgery, the difference between methods was significant. The FemtoLASIK method resulted in an average SE -0.55 D compared to -0.09 D for the ReLEx SMILE method, (P<0.001). CONCLUSION This study showed that there was a significant difference in results between the two surgical methods of treatment of moderate myopia and astigmatism, in terms of regression of dioptric error, as well as in achievement and maintenance of visual acuity during the observed period. The ReLEx SMILE had better results.
Collapse
|
20
|
Ganesh S, Brar S, Arra RR. Refractive lenticule extraction small incision lenticule extraction: A new refractive surgery paradigm. Indian J Ophthalmol 2018; 66:10-19. [PMID: 29283117 PMCID: PMC5778540 DOI: 10.4103/ijo.ijo_761_17] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Small incision lenticule extraction (SMILE), a variant of refractive lenticule extraction technology is becoming increasingly popular, as a flapless and minimally invasive form of laser vision correction (LVC) for the treatment of myopia and myopic astigmatism. This review aims at summarizing the principles, surgical technique, and clinical outcomes in terms of visual and refractive results, safety, efficacy, postoperative dry eye, aberrations, and biomechanics of SMILE and its comparison with other conventional techniques of LVC, such as laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK). Recent advancements in the laser frequency and energy delivery patterns, instrumentation, and surgical techniques have shown significant improvement in the visual recovery and outcomes after SMILE, compared to the initial results published by Sekundo and Shah et al. Most of the recently published literature on long-term outcomes of SMILE shows excellent stability of the procedure, especially for higher myopia. In terms of the postoperative dry eye, SMILE shows a clear advantage over LASIK as numerous studies have shown significant differences about the Schirmer's, Tear film break up time, corneal sensitivity, and corneal nerve regeneration to be better following SMILE compared to LASIK. There is some evidence that since the Bowman's membrane (BM) and the anterior lamellae remain intact after SMILE, this may be a potential advantage for corneal biomechanics over LASIK and PRK where the BM is either severed or ablated, respectively, however, the data on biomechanics are inconclusive at present. Overall, this procedure has proved to be promising, delivering equivalent, or better visual and refractive results to LASIK and providing clear advantage in terms of being a flapless, minimally invasive procedure with minimal pain and postoperative discomfort thus offering high patient satisfaction.
Collapse
Affiliation(s)
- Sri Ganesh
- Department of Phaco-Refractive, Nethradhama Superspeciality Eye Hospital, Bengaluru, Karnataka, India
| | - Sheetal Brar
- Department of Phaco-Refractive, Nethradhama Superspeciality Eye Hospital, Bengaluru, Karnataka, India
| | - Raghavender Reddy Arra
- Department of Phaco-Refractive, Nethradhama Superspeciality Eye Hospital, Bengaluru, Karnataka, India
| |
Collapse
|
21
|
Chandapura RS, Shetty R, Shroff R, Shilpy N, Francis M, Sinha Roy A. OCT layered tomography of the cornea provides new insights on remodeling after photorefractive keratectomy. JOURNAL OF BIOPHOTONICS 2018; 11:e201700027. [PMID: 28700139 DOI: 10.1002/jbio.201700027] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2017] [Revised: 05/25/2017] [Accepted: 05/25/2017] [Indexed: 06/07/2023]
Abstract
OCT (optical coherence tomography) of corneal layers was generated to analyze the remodeling of the epithelium and stroma after photorefractive keratectomy (PRK). Myopic PRK was performed in 15 patients. One eye underwent manual scraping of epithelium while the other was treated with Epi clear. Epi clear allowed a gentler removal of the epithelium compared to manual scraping. Scheimpflug (Pentacam, OCULUS Optikgerate Gmbh, Wetzlar, Germany) and OCT (RTVue, Optovue Inc., Fremont, California, USA) scans of the cornea were performed before and after PRK (3 months). The OCT scanner and Pentacam acquired 8 and 25 radial 2-D scans of the cornea, respectively. The results showed similar topographic changes on the anterior corneal surface between Scheimpflug and OCT imaging. The curvature of the underlying anterior surface of the stroma after PRK was similar to the anterior corneal surface (air-epithelium interface), when measured with OCT. Aberrometric changes were mostly similar between Scheimpflug and OCT. However, Scheimpflug imaging reported greater changes in spherical aberration and corneal higher order aberrations than OCT after PRK. This is the first study to quantify the curvatures of the stromal layers with OCT after PRK. New insights were gained, which could be useful for refinement of surgical ablation algorithms, refractive procedures and detection of ectasia.
Collapse
Affiliation(s)
- Rachana S Chandapura
- Imaging, Biomechanics and Mathematical Modeling Solutions, Narayana Nethralaya Foundation, Bangalore, India
| | - Rohit Shetty
- Division of Cornea and Refractive Surgery, Narayana Nethralaya Foundation, Bangalore, India
| | - Rushad Shroff
- Division of Cornea and Refractive Surgery, Narayana Nethralaya Foundation, Bangalore, India
| | - Neha Shilpy
- Division of Cornea and Refractive Surgery, Narayana Nethralaya Foundation, Bangalore, India
| | - Mathew Francis
- Imaging, Biomechanics and Mathematical Modeling Solutions, Narayana Nethralaya Foundation, Bangalore, India
| | - Abhijit Sinha Roy
- Imaging, Biomechanics and Mathematical Modeling Solutions, Narayana Nethralaya Foundation, Bangalore, India
| |
Collapse
|
22
|
Recchioni A, Hartwig A, Dermott J, Vaswani S, Bhatt J, Morris R, O’Donnell C. Early clinical outcomes after small incision lenticule extraction surgery (SMILE). Cont Lens Anterior Eye 2018; 41:132-135. [DOI: 10.1016/j.clae.2017.10.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2017] [Revised: 10/09/2017] [Accepted: 10/10/2017] [Indexed: 11/28/2022]
|
23
|
Achiron A, Gur Z, Aviv U, Hilely A, Mimouni M, Karmona L, Rokach L, Kaiserman I. Predicting Refractive Surgery Outcome: Machine Learning Approach With Big Data. J Refract Surg 2017; 33:592-597. [DOI: 10.3928/1081597x-20170616-03] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2017] [Accepted: 05/16/2017] [Indexed: 12/19/2022]
|
24
|
Kanellopoulos AJ. Topography-Guided LASIK Versus Small Incision Lenticule Extraction (SMILE) for Myopia and Myopic Astigmatism: A Randomized, Prospective, Contralateral Eye Study. J Refract Surg 2017; 33:306-312. [DOI: 10.3928/1081597x-20170221-01] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2016] [Accepted: 02/03/2017] [Indexed: 11/20/2022]
|
25
|
Yildirim Y, Olcucu O, Alagoz C, Basci A, Agca A, Yasa D, Ozgurhan EB, Demirok A. Visual and Refractive Outcomes of Photorefractive Keratectomy and Small Incision Lenticule Extraction (SMILE) for Myopia. J Refract Surg 2016; 32:604-10. [DOI: 10.3928/1081597x-20160602-02] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2015] [Accepted: 05/19/2016] [Indexed: 11/20/2022]
|
26
|
Holladay JT, Galvis V, Tello A. Re: Wang et al.: Comparison of newer intraocular lens power calculation methods for eyes after corneal refractive surgery (Ophthalmology 2015;122:2443-9). Ophthalmology 2016; 123:e55-6. [PMID: 27549891 DOI: 10.1016/j.ophtha.2016.02.038] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2016] [Revised: 02/05/2016] [Accepted: 02/05/2016] [Indexed: 11/28/2022] Open
Affiliation(s)
| | - Virgilio Galvis
- Centro Oftalmologico Virgilio Galvis, Floridablanca, Colombia; Universidad Autonoma de Bucaramanga, Bucaramanga, Colombia
| | - Alejandro Tello
- Centro Oftalmologico Virgilio Galvis, Floridablanca, Colombia; Universidad Autonoma de Bucaramanga, Bucaramanga, Colombia.
| |
Collapse
|
27
|
Mohammadpour M, Hashemi H, Jabbarvand M, Rahmatnejad K, Sabet FA. Efficacy of Wavefront-guided Photorefractive Keratectomy with Iris Registration for Management of Moderate to High Astigmatism by Advanced Personalized Treatment Nomogram. J Ophthalmic Vis Res 2016; 11:136-40. [PMID: 27413491 PMCID: PMC4926558 DOI: 10.4103/2008-322x.183913] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Purpose: To evaluate the efficacy of photorefractive keratectomy (PRK) using the advanced personalized treatment (APT) nomogram for correction of moderate to high astigmatism. Methods: This prospective interventional case series included 60 consecutive eyes of 30 patients undergoing wavefront-guided PRK (Zyoptix 217 Z100 excimer laser, Bausch & Lomb, Munich, Germany) using the APT nomogram and iris registration for myopic astigmatism. Mitomycin-C was applied intraoperatively in all eyes. Ophthalmic examination was performed preoperatively and 1, 3 and 6 months postoperatively. Results: Preoperatively, mean sphere was -1.68 ± 2.08 diopters (D), mean refractive astigmatism was -3.04 ± 1.05 D and mean spherical equivalent (SE) was -3.12 ± 1.77 D. Six months postoperatively, mean sphere was + 0.60 ± 0.64 D (P < 0.005), mean cylinder was -0.43 ± 0.46 D (P < 0.005) and mean SE was + 0.28 ± 0.48 D (P < 0.005). Hyperopic overcorrection (≥ +1.0 D) occurred in 3 (5%) eyes. Postoperatively, root mean square (RMS) of higher order aberrations (HOAs) was significantly increased (P = 0.041). RMS of spherical aberration (Z [4, 0]) showed no significant change after surgery (P = 0.972). Conclusion: Considering the acceptable residual refractive error, low rate of hyperopic overcorrection, acceptable uncorrected visual acuity, and low risk of postoperative corneal haze, PRK using the APT nomogram with iris registration and mitomycin-C use is a safe and effective modality for treatment of moderate to high astigmatism.
Collapse
Affiliation(s)
- Mehrdad Mohammadpour
- Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Hassan Hashemi
- Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Mahmoud Jabbarvand
- Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Kamran Rahmatnejad
- Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Fatemeh Alsadat Sabet
- Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
28
|
Piñero-Llorens DP, Murueta-Goyena Larrañaga A, Hanneken L. Visual outcomes and complications of small-incision lenticule extraction: a review. EXPERT REVIEW OF OPHTHALMOLOGY 2016. [DOI: 10.1586/17469899.2016.1131610] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
29
|
Son GS, Lee SC, Lim TH. Clinical Outcome of Small Incision Lenticule Extraction including Visual Quality Analysis. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2016. [DOI: 10.3341/jkos.2016.57.4.562] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
30
|
|
31
|
Liu R, Zhao J, Xu Y, Li M, Niu L, Liu H, Sun L, Chu R, Zhou X. Femtosecond Laser-Assisted Corneal Small Incision Allogenic Intrastromal Lenticule Implantation in Monkeys: A Pilot Study. Invest Ophthalmol Vis Sci 2015; 56:3715-20. [PMID: 26047173 DOI: 10.1167/iovs.14-15296] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE Lenticule implantation can be used to correct vision problems. However, it is significantly restrained by the sources of autologous lenticules. The aim of the present study was to investigate the feasibility and effects of femtosecond laser-assisted corneal small incision allogenic intrastromal lenticule implantation (AILI) in monkeys. METHODS Six healthy adult monkeys were included in this study. Femtosecond lenticule extraction (-4.0 diopter [D] correction, 5.0-mm optical zone) was performed in one eye of two monkeys and both eyes of one monkey. Each extracted refractive lenticule was allogenically transplanted into a femtosecond laser-created corneal stromal pocket in one eye of the other two monkeys and one monkey's both eyes. Pre- and postoperative (1 or 3 days, 1 month, and 6 months) slit lamp microscopy, corneal topography, anterior segment optical coherence tomography, and in vivo confocal microscopy were performed. RESULTS Corneal edema occurred in the early postoperative days with a large number of hyperreflective particles around the borders. Corneal tissue edema gradually decreased. Nerve fiber regeneration could be detected in the lenticule layer at 6 months. Overall, 3.27 ± 1.2 D corneal power was increased at 6 months, accounting for 82% of the intended correction. At the same time point, corneal stroma was 69 ± 11 μm thicker than preoperative ones and was roughly equal to the maximum thickness of implanted lenticules. No significant complications were observed. CONCLUSIONS The AILI technique seems to be feasible and safe for increasing corneal stromal thickness and changing corneal refractive power, which may provide a useful method for treatment of keratoectasia, presbyopia, and hyperopia.
Collapse
Affiliation(s)
- Rui Liu
- Key Laboratory of Myopia Ministry of Health, Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | - Jing Zhao
- Key Laboratory of Myopia Ministry of Health, Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | - Ye Xu
- Key Laboratory of Myopia Ministry of Health, Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | - Meiyan Li
- Key Laboratory of Myopia Ministry of Health, Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | - Lingling Niu
- Key Laboratory of Myopia Ministry of Health, Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | | | - Ling Sun
- Key Laboratory of Myopia Ministry of Health, Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | - Renyuan Chu
- Key Laboratory of Myopia Ministry of Health, Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | - Xingtao Zhou
- Key Laboratory of Myopia Ministry of Health, Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| |
Collapse
|
32
|
Aristeidou A, Taniguchi EV, Tsatsos M, Muller R, McAlinden C, Pineda R, Paschalis EI. The evolution of corneal and refractive surgery with the femtosecond laser. EYE AND VISION 2015; 2:12. [PMID: 26605365 PMCID: PMC4655461 DOI: 10.1186/s40662-015-0022-6] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2015] [Accepted: 06/20/2015] [Indexed: 01/12/2023]
Abstract
The use of femtosecond lasers has created an evolution in modern corneal and refractive surgery. With accuracy, safety, and repeatability, eye surgeons can utilize the femtosecond laser in almost all anterior refractive procedures; laser in situ keratomileusis (LASIK), small incision lenticule extraction (SMILE), penetrating keratoplasty (PKP), insertion of intracorneal ring segments, anterior and posterior lamellar keratoplasty (Deep anterior lamellar keratoplasty (DALK) and Descemet's stripping endothelial keratoplasty (DSEK)), insertion of corneal inlays and cataract surgery. As the technology matures, it will push surgical limits and open new avenues for ophthalmic intervention in areas not yet explored. As we witness the transition from femto-LASIK to femto-cataract surgery it becomes obvious that this innovation is here to stay. This article presents some of the most relevant advances of femtosecond lasers to modern corneal and refractive surgery.
Collapse
Affiliation(s)
| | - Elise V Taniguchi
- Massachusetts Eye and Ear Infirmary, Department of Ophthalmology, Harvard Medical School, Boston, MA USA ; Massachusetts Eye and Ear Infirmary/Schepens Eye Research Institute, Boston Keratoprosthesis Laboratory, Harvard Medical School, Boston, 02114 MA USA
| | | | - Rodrigo Muller
- Massachusetts Eye and Ear Infirmary, Department of Ophthalmology, Harvard Medical School, Boston, MA USA
| | - Colm McAlinden
- Flinders University, Adelaide, South Australia Australia ; Wenzhou Medical University, Wenzhou, Zhejiang China
| | - Roberto Pineda
- Massachusetts Eye and Ear Infirmary, Department of Ophthalmology, Harvard Medical School, Boston, MA USA
| | - Eleftherios I Paschalis
- Massachusetts Eye and Ear Infirmary, Department of Ophthalmology, Harvard Medical School, Boston, MA USA ; Massachusetts Eye and Ear Infirmary/Schepens Eye Research Institute, Boston Keratoprosthesis Laboratory, Harvard Medical School, Boston, 02114 MA USA
| |
Collapse
|
33
|
Vestergaard AH. Past and present of corneal refractive surgery: a retrospective study of long-term results after photorefractive keratectomy, and a prospective study of refractive lenticule extraction. Acta Ophthalmol 2014; 92:492-3. [PMID: 25043790 DOI: 10.1111/aos.12450] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Anders Højslet Vestergaard
- Faculty of Health Science; University of Southern Denmark, and Department of Ophthalmology, Odense University Hospital; Odense Denmark
| |
Collapse
|