1
|
Meretsky CR, Mahmoodi A, Knecht EM, Popovich J, Schiuma AT. The Impact of Electrocautery Smoke on Surgical Staff and the Efficacy of Normal Surgical Masks Versus N95 Masks. Cureus 2024; 16:e58106. [PMID: 38738122 PMCID: PMC11088792 DOI: 10.7759/cureus.58106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/12/2024] [Indexed: 05/14/2024] Open
Abstract
Electrocautery is a commonly used technique in surgical procedures, generating smoke that poses health risks to surgical staff. This study investigates the comparative efficacy of normal surgical masks versus N95 masks in mitigating the harmful effects of electrocautery smoke. Through a systematic review of literature spanning two decades, we explore the causes and effects of electrocautery smoke exposure, including potential long-term inhalation effects. Our findings highlight significant disparities in the protection offered by different masks and underscore the importance of adequate respiratory protection in surgical settings. In addition, we examine the factors influencing the generation and composition of electrocautery smoke, such as the power settings used, the type of tissue being cauterized, and the duration of the procedure. Furthermore, we discuss the potential health risks associated with long-term exposure to electrocautery smoke, including the possibility of respiratory conditions, cardiovascular effects, and carcinogenicity. Our analysis also addresses the importance of implementing appropriate smoke evacuation systems and optimizing operating room ventilation to minimize the concentration of smoke particles in the surgical environment. Overall, this comprehensive analysis provides valuable insights into the impact of electrocautery smoke in surgical settings and the varying levels of protection offered by different masks.
Collapse
Affiliation(s)
| | - Arshia Mahmoodi
- Surgery, St. George's University School of Medicine, Great River, USA
| | - Erik M Knecht
- Surgery, Chicago Medical School at Rosalind Franklin University, Chicago, USA
| | - Jay Popovich
- Internal Medicine, St. George's University School of Medicine, Great River, USA
| | | |
Collapse
|
2
|
Nose Y, Kato M, Aoyagi S, Akeo K, Yamashita K, Saito T, Tanaka K, Yamamoto K, Makino T, Takahashi T, Kurokawa Y, Eguchi H, Doki Y, Nakajima K. Use of current automatic smoke evacuation system in flexible gastrointestinal endoscopy: Its feasibility and potential usefulness. DEN OPEN 2024; 4:e367. [PMID: 38605997 PMCID: PMC11007223 DOI: 10.1002/deo2.367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 03/28/2024] [Accepted: 04/02/2024] [Indexed: 04/13/2024]
Abstract
Objectives Flexible endoscopy does not have a system that can automatically evacuate surgical smoke generated in the gastrointestinal lumen. We aimed to investigate the feasibility and potential usefulness of automatic smoke evacuation systems in flexible endoscopy. Methods [Bench] After surgical smoke generated in the stomach was evacuated by the evacuator, the degree of residual smoke and gastric luminal collapse were evaluated to optimize the evacuator settings. [Animal] Insufflation, suction, and total operation time to complete the protocol of 10 cauterizations of the gastric mucosa were measured in three groups: "manual suction only," "manual suction with automatic evacuation (50% force)," and "manual suction with automatic evacuation (70% force)." The stability of endoscopic visualization and operability was evaluated by 10 endoscopists blinded to those suction settings, and the number of manual suctions, insufflations, and total operation time were measured. Results [Bench] The degree of residual smoke and gastric luminal collapse were inversely correlated. [Animal] When the automatic evacuator was partially used, there was no difference in the insufflation time, but the suction time (vs 50%; p = 0.011, vs. 70%; p = 0.011) and total operation time (vs. 50%; p = 0.012, vs. 70%; p = 0.036) were significantly reduced compared to manual operation only. Furthermore, manual suction with automatic evacuation (50% force) significantly improved the stability of endoscopic visualization and operability compared to manual operation only (p = 0.041, p = 0.0085). Conclusions The automatic smoke evacuation in flexible gastrointestinal endoscopy was potentially feasible and useful by improving the device setting.
Collapse
Affiliation(s)
- Yohei Nose
- Department of Next Generation Endoscopic Intervention (Project ENGINE)Graduate School of Medicine, Osaka UniversityOsakaJapan
- Department of Gastroenterological SurgeryGraduate School of Medicine Osaka UniversityOsakaJapan
| | - Motohiko Kato
- Center for Diagnostic and Therapeutic EndoscopyKeio University School of MedicineTokyoJapan
| | | | | | - Kotaro Yamashita
- Department of Gastroenterological SurgeryGraduate School of Medicine Osaka UniversityOsakaJapan
| | - Takuro Saito
- Department of Gastroenterological SurgeryGraduate School of Medicine Osaka UniversityOsakaJapan
| | - Koji Tanaka
- Department of Gastroenterological SurgeryGraduate School of Medicine Osaka UniversityOsakaJapan
| | - Kazuyoshi Yamamoto
- Department of Gastroenterological SurgeryGraduate School of Medicine Osaka UniversityOsakaJapan
| | - Tomoki Makino
- Department of Gastroenterological SurgeryGraduate School of Medicine Osaka UniversityOsakaJapan
| | - Tsuyoshi Takahashi
- Department of Gastroenterological SurgeryGraduate School of Medicine Osaka UniversityOsakaJapan
| | - Yukinori Kurokawa
- Department of Gastroenterological SurgeryGraduate School of Medicine Osaka UniversityOsakaJapan
| | - Hidetoshi Eguchi
- Department of Gastroenterological SurgeryGraduate School of Medicine Osaka UniversityOsakaJapan
| | - Yuichiro Doki
- Department of Gastroenterological SurgeryGraduate School of Medicine Osaka UniversityOsakaJapan
| | - Kiyokazu Nakajima
- Department of Next Generation Endoscopic Intervention (Project ENGINE)Graduate School of Medicine, Osaka UniversityOsakaJapan
- Department of Gastroenterological SurgeryGraduate School of Medicine Osaka UniversityOsakaJapan
| |
Collapse
|
3
|
Li C, Geng M, Li S, Li X, Li H, Yuan H, Liu F. Knowledge mapping of surgical smoke from 2003 to 2022: a bibliometric analysis. Surg Endosc 2024; 38:1465-1483. [PMID: 38228836 PMCID: PMC10881617 DOI: 10.1007/s00464-023-10641-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Accepted: 11/29/2023] [Indexed: 01/18/2024]
Abstract
PURPOSE The purpose of this study is to identify and characterize the literature on surgical smoke, visualize the data and sketch a certain trending outline. METHODS In the Web of Science Core Collection (WoSCC), all the data were acquired from January 1st 2003 to December 31st 2022. VOSviewer and CiteSpace were employed to visualize data, based on publications, bibliographic coupling, co-citation, or co-authorship relations. Microsoft Excel 2019 was used to comb and categorize all the statistics. RESULT A total 363 of journal papers were retrieved. The publication number was in a slow but steady growth between 2003 and 2019, followed by a sharp surge in 2020, and then the publication kept in a productive way. Surgical endoscopy and other interventional techniques was the most active journal on surgical smoke. USA played an important role among all the countries/regions. There were 1847 authors for these 363 papers, among whom 44 authors published more than three articles on surgical smoke. "Surgical smoke", "covid-19" and "surgery" were the top 3 appeared keywords, while the latest hot-spot keywords were "COVID-19", "virus", "transmission", "exposure" and "risk". There were 1105 co-cited references and 3786 links appeared in all 363 articles. Among them, 38 references are cited more than 10 times. The most co-cited article was "Detecting hepatitis B virus in surgical smoke emitted during laparoscopic surgery." Based on the titles of references and calculated by CiteSpace, the top 3 cluster trend network are "laparoscopic surgery", "COVID-19 pandemic" and "surgical smoke". CONCLUSION According to bibliometric analysis, the research on surgical smoke has been drawing attention of more scholars in the world. Increasing number of countries or regions added in this field, and among them, USA, Italy, and China has been playing important roles, however, more wide and intense cooperation is still in expectation.
Collapse
Affiliation(s)
- Chuang Li
- The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Meng Geng
- The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Shujun Li
- The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Xianglan Li
- Hebei Medical University Third Hospital, Shijiazhuang, China
| | - Huiqin Li
- The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Hufang Yuan
- The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Fengxia Liu
- The Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
| |
Collapse
|
4
|
Chae HC, Kim BJ, Choi YS, Suh SW, Lee SE. Efficacy of Filter Trocar for Clear Visualization during Laparoscopic Cholecystectomy: A Prospective Randomized Controlled Trial. J Pers Med 2024; 14:204. [PMID: 38392637 PMCID: PMC10890709 DOI: 10.3390/jpm14020204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 02/02/2024] [Accepted: 02/12/2024] [Indexed: 02/24/2024] Open
Abstract
Filter trocar designed to eliminate harmful smoke is also regarded as effective for improving surgical visualization. The aim of this study is to evaluate the efficacy of filter trocar in maintaining clear operative view. From 2019 to 2020, 100 patients underwent laparoscopic cholecystectomy and they were randomized to either the control or filter group. The primary end point was a laparoscopic operative view score (1, clear; 2, slightly blurry; 3, completely blurry) during gallbladder dissection from the liver bed when dissection was started (LV1), when dissection was half completed (LV2) and when dissection was completed (LV3). Between the control and filter groups, there were no significant differences in mean LV1 (1.44 vs. 1.40, p = 0.234) and LV3 (1.86 vs. 2.01, p = 0.880). There was no significant difference in the mean duration of suction after dissection (3.82 s vs. 3.67 s, p = 0.097) and the mean number of laparoscope removals from inside to outside the body to clean during gallbladder dissection from the liver bed (0.55 vs. 0.22, p = 0.963) or the mean amount of time required to dissect the gallbladder from the liver bed (221.58 s vs. 177.09 s, p = 0.253). The study demonstrated that filter trocar is not as effective as expected in the maintenance of clear operative view. Further study is needed to develop devices to improve clear surgical visualization.
Collapse
Affiliation(s)
- Ho-Chang Chae
- Samsung Medical Center, Division of Hepatobiliary-Pancreatic Surgery, Department of Surgery, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
| | - Beom-Jin Kim
- Department of Surgery, Seoul Song-do Hospital, Seoul 04597, Republic of Korea
| | - Yoo Shin Choi
- Department of Surgery, Chung-Ang University College of Medicine, Seoul 06974, Republic of Korea
| | - Suk-Won Suh
- Department of Surgery, Chung-Ang University College of Medicine, Seoul 06974, Republic of Korea
| | - Seung Eun Lee
- Department of Surgery, Chung-Ang University College of Medicine, Seoul 06974, Republic of Korea
| |
Collapse
|
5
|
Zhou YZ, Wang CQ, Zhou MH, Li ZY, Chen D, Lian AL, Ma Y. Surgical smoke: A hidden killer in the operating room. Asian J Surg 2023; 46:3447-3454. [PMID: 37002044 DOI: 10.1016/j.asjsur.2023.03.066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 01/12/2023] [Accepted: 03/15/2023] [Indexed: 03/31/2023] Open
Abstract
Surgical smoke is a byproduct of aerosols containing several components produced by energy equipment. The characteristics of surgical smoke components produced by different types of tissues or using different kinds of energy devices vary. For example, the average diameter of smoke particles produced by electrocautery is smaller, and the possibility of viable cells and pathogens in surgical smoke produced by an ultrasonic knife is higher. According to the characteristics of its composition, surgical smoke may be an important risk factor affecting the health and safety of operating room staff and patients. The use of surgical masks, suction devices and portable smoke evacuation systems can reduce this risk to some extent. However, most operating room staff members do not implement corresponding measures to protect themselves. In this paper, the characteristics of surgical smoke and the research progress in protective measures are briefly reviewed.
Collapse
Affiliation(s)
- Yong-Zhi Zhou
- Department of Minimal Invasive Hepatic Surgery of the First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China; Key Laboratory of Hepatosplenic Surgery, Ministry of Education, Harbin, 150001, China
| | - Chao-Qun Wang
- Department of Minimal Invasive Hepatic Surgery of the First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China; Key Laboratory of Hepatosplenic Surgery, Ministry of Education, Harbin, 150001, China
| | - Meng-Hua Zhou
- Key Laboratory of Hepatosplenic Surgery, Ministry of Education, Harbin, 150001, China; Department of Hepatic Surgery, The First Affliated Hospital of Harbin Medical University, Harbin, 150001, China
| | - Zhong-Yu Li
- Department of Minimal Invasive Hepatic Surgery of the First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China; Key Laboratory of Hepatosplenic Surgery, Ministry of Education, Harbin, 150001, China
| | - Dong Chen
- Department of Minimal Invasive Hepatic Surgery of the First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China; Key Laboratory of Hepatosplenic Surgery, Ministry of Education, Harbin, 150001, China
| | - Ai-Ling Lian
- Operating Room, The First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China.
| | - Yong Ma
- Department of Minimal Invasive Hepatic Surgery of the First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China; Key Laboratory of Hepatosplenic Surgery, Ministry of Education, Harbin, 150001, China.
| |
Collapse
|
6
|
Hayashi Y, Ishii Y, Ishida T, Yamashita K, Saito T, Tanaka K, Yamamoto K, Makino T, Takahashi T, Kurokawa Y, Eguchi H, Doki Y, Nakajima K. Management of abdominal gas leakage from surgical trocars in laparoscopic surgery: a preclinical study. MINIM INVASIV THER 2023; 32:183-189. [PMID: 37288765 DOI: 10.1080/13645706.2023.2211661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 05/01/2023] [Indexed: 06/09/2023]
Abstract
Introduction: There is an ongoing concern about the potential infectious risk due to pneumoperitoneal gas leakage from surgical trocars in laparoscopic surgery. We aimed to visually confirm the presence of leakage from trocars and investigate the changes in the leakage scale according to intra-abdominal pressures and trocar types. Material and methods: We established a porcine pneumoperitoneum model and performed experimental forceps manipulation using 5-mm grasping forceps with 12-mm trocars. The gas leakage, if any, was imaged using a Schlieren optical system, which can visualize minute gas flow invisible to the naked eye. For measuring the scale, we calculated the gas leakage velocity and area using image analysis software. Four types of unused and exhausted disposable trocars were compared. Results: Gas leakage was observed from trocars during forceps insertion and removal. Both the gas leakage velocity and area increased as the intra-abdominal pressure increased. Every type of trocar we handled was associated with gas leakage, and exhausted disposable trocars had the largest scale gas leakage. Conclusions: We confirmed gas leakage from trocars during device traffic. The scale of leakage increased with high intra-abdominal pressure and with the use of exhausted trocars. Current protection against gas leakage may not be sufficient and new surgical safety measures and device development may be needed in the future.
Collapse
Affiliation(s)
- Yoshinori Hayashi
- Department of Next Generation Endoscopic Intervention (Project ENGINE), Graduate School of Medicine, Osaka University, Osaka, Japan
- Department of Gastroenterological Surgery, Graduate School of Medicine, Osaka University, Osaka, Japan
| | | | - Tomo Ishida
- Department of Next Generation Endoscopic Intervention (Project ENGINE), Graduate School of Medicine, Osaka University, Osaka, Japan
- Department of Gastroenterological Surgery, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Kotaro Yamashita
- Department of Gastroenterological Surgery, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Takuro Saito
- Department of Gastroenterological Surgery, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Koji Tanaka
- Department of Gastroenterological Surgery, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Kazuyoshi Yamamoto
- Department of Gastroenterological Surgery, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Tomoki Makino
- Department of Gastroenterological Surgery, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Tsuyoshi Takahashi
- Department of Gastroenterological Surgery, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Yukinori Kurokawa
- Department of Gastroenterological Surgery, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Hidetoshi Eguchi
- Department of Gastroenterological Surgery, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Yuichiro Doki
- Department of Gastroenterological Surgery, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Kiyokazu Nakajima
- Department of Next Generation Endoscopic Intervention (Project ENGINE), Graduate School of Medicine, Osaka University, Osaka, Japan
- Department of Gastroenterological Surgery, Graduate School of Medicine, Osaka University, Osaka, Japan
| |
Collapse
|