1
|
Pogue BW, Zhu TC, Ntziachristos V, Wilson BC, Paulsen KD, Gioux S, Nordstrom R, Pfefer TJ, Tromberg BJ, Wabnitz H, Yodh A, Chen Y, Litorja M. AAPM Task Group Report 311: Guidance for performance evaluation of fluorescence-guided surgery systems. Med Phys 2024; 51:740-771. [PMID: 38054538 DOI: 10.1002/mp.16849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 11/02/2023] [Accepted: 11/06/2023] [Indexed: 12/07/2023] Open
Abstract
The last decade has seen a large growth in fluorescence-guided surgery (FGS) imaging and interventions. With the increasing number of clinical specialties implementing FGS, the range of systems with radically different physical designs, image processing approaches, and performance requirements is expanding. This variety of systems makes it nearly impossible to specify uniform performance goals, yet at the same time, utilization of different devices in new clinical procedures and trials indicates some need for common knowledge bases and a quality assessment paradigm to ensure that effective translation and use occurs. It is feasible to identify key fundamental image quality characteristics and corresponding objective test methods that should be determined such that there are consistent conventions across a variety of FGS devices. This report outlines test methods, tissue simulating phantoms and suggested guidelines, as well as personnel needs and professional knowledge bases that can be established. This report frames the issues with guidance and feedback from related societies and agencies having vested interest in the outcome, coming from an independent scientific group formed from academics and international federal agencies for the establishment of these professional guidelines.
Collapse
Affiliation(s)
- Brian W Pogue
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA
| | - Timothy C Zhu
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Vasilis Ntziachristos
- Institute for Biological and Medical Imaging, Technical University of Munich, Helmholtz Zentrum Munich, Munich, Germany
| | - Brian C Wilson
- Department of Medical Biophysics, University of Toronto, University Health Network, Toronto, Ontario, Canada
| | - Keith D Paulsen
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA
| | - Sylvain Gioux
- Department of Biomedical Engineering, University of Strasbourg, Strasbourg, France
| | - Robert Nordstrom
- Cancer Imaging Program, National Cancer Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - T Joshua Pfefer
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, USA
| | - Bruce J Tromberg
- National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, Maryland, USA
| | | | - Arjun Yodh
- Department of Physics, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Yu Chen
- Department of Biomedical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts, USA
| | - Maritoni Litorja
- Sensor Science Division, National Institute of Standards and Technology, Gaithersburg, Maryland, USA
| |
Collapse
|
2
|
Shcheslavskiy VI, Shirmanova MV, Dudenkova VV, Lukyanov KA, Gavrina AI, Shumilova AV, Zagaynova E, Becker W. Fluorescence time-resolved macroimaging. OPTICS LETTERS 2018; 43:3152-3155. [PMID: 29957804 DOI: 10.1364/ol.43.003152] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2018] [Accepted: 05/08/2018] [Indexed: 06/08/2023]
Abstract
While laser scanning fluorescence lifetime imaging (FLIM) is a powerful approach for cell biology, its small field of view (typically less than 1 mm) makes it impractical for the imaging of large biological samples that is often required for biomedical applications. Here we present a system that allows performing FLIM on macroscopic samples as large as 18 mm with a lateral resolution of 15 μm. The performance of the system is verified with FLIM of endogenous metabolic cofactor reduced nicotinamide adenine dinucleotide (phosphate), NAD(P)H, and genetically encoded fluorescent protein mKate2 in a mouse tumor in vivo.
Collapse
|
3
|
Ha Y, Choi HK. Recent conjugation strategies of small organic fluorophores and ligands for cancer-specific bioimaging. Chem Biol Interact 2016; 248:36-51. [DOI: 10.1016/j.cbi.2016.02.006] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2015] [Revised: 02/02/2016] [Accepted: 02/08/2016] [Indexed: 01/03/2023]
|