1
|
Wan Q, He P, Wei R, Ma K, Yin H, Tang J, Deng YP. Long-term observation of V4c implantable collamer lenses implantation for moderate to extreme high myopia correction: five years follow-up. Eye (Lond) 2024; 38:1933-1940. [PMID: 38519715 PMCID: PMC11226664 DOI: 10.1038/s41433-024-03046-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 03/06/2024] [Accepted: 03/18/2024] [Indexed: 03/25/2024] Open
Abstract
BACKGROUND This study aims to assess the long term effectiveness, safety, predictability and stability of V4c implantable collamer lenses (ICL) for correction of moderate to extreme high myopia. METHODS We reviewed 125 eyes from 64 patients who implanted V4c ICL at the Refractive Surgery Center of West China Hospital in Chengdu, China, between May 2015 and January 2017. The median spherical equivalent was -11.50 D (interquartile range [IQR]: -13.00 to -9.00 D). We followed up with the patients over five years and evaluated several parameters, including uncorrected visual acuity (UDVA), corrected visual acuity (CDVA), axial length, refractive error, endothelial cell density (ECD), intraocular pressure (IOP), white-to-white distance (WTW), and vault. We performed a correlation analysis to explore the potential impacts on vault following implantation. RESULTS The median safety index (postoperative CDVA/preoperative CDVA) during the last follow-up was 1.00 (interquartile range [IQR]: 1.00-1.20), and the efficacy indices (postoperative UDVA/preoperative CDVA) were 1.20 (IQR: 1.00-1.25), 1.20 (IQR: 1.00-1.33), and 0.8 (IQR: 0.65-1.00) at postoperative 1 week, 1 month, and 5 years, respectively. At the five-year mark, 16% of the eyes were within ±0.50 D of expected correction, and 73% were within ±2.00 D. No significant difference in ECD was observed between pre-operative and post-operative measurements. Compared to baseline, we observed a significant increase in IOP at the one-week follow-up, which decreased significantly at the one-month visit. Furthermore, we identified ICL size and spherical equivalent (SE) as independent variables in a multiple linear regression model that accurately predicted the five-year vault after surgery. CONCLUSION In conclusion, V4c ICL implantation is an effective and safe treatment for moderate to extreme high myopia with good predictability and stability over the long-term.
Collapse
Affiliation(s)
- Qi Wan
- Department of Ophthalmology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Peiyuan He
- Department of Ophthalmology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
- Department of Health Management & Institute of Health Management, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, Sichuan, China
| | - Ran Wei
- Department of Ophthalmology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Ke Ma
- Department of Ophthalmology, West China Hospital of Sichuan University, Chengdu, Sichuan, China.
| | - Hongbo Yin
- Department of Ophthalmology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Jing Tang
- Department of Ophthalmology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Ying-Ping Deng
- Department of Ophthalmology, West China Hospital of Sichuan University, Chengdu, Sichuan, China.
| |
Collapse
|
2
|
Jiang Y, Shen Y, Wang L, Chen X, Tang J, Liu L, Ma T, Ju L, Chen Y, Ge Z, Zhou X, Wang X. Effect of vault on predicting postoperative refractive error for posterior chamber phakic intraocular lens based on a machine learning model. J Cataract Refract Surg 2024; 50:319-327. [PMID: 37938020 DOI: 10.1097/j.jcrs.0000000000001356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Accepted: 10/26/2023] [Indexed: 11/09/2023]
Abstract
PURPOSE To investigate how vault and other biometric variations affect postoperative refractive error of implantable collamer lenses (ICLs) by integrating artificial intelligence and modified vergence formula. SETTING Eye and ENT Hospital of Fudan University, Shanghai, China. DESIGN Artificial intelligence and big data-based prediction model. METHODS 2845 eyes that underwent uneventful spherical ICL or toric ICL implantation and with manifest refraction results 1 month postoperatively were included. 1 eye of each patient was randomly included. Random forest was used to calculate the postoperative sphere, cylinder, and spherical equivalent by inputting variable ocular parameters. The influence of predicted vault and modified Holladay formula on predicting postoperative refractive error was analyzed. Subgroup analysis of ideal vault (0.25 to 0.75 mm) and extreme vault (<0.25 mm or >0.75 mm) was performed. RESULTS In the test set of both ICLs, all the random forest-based models significantly improved the accuracy of predicting postoperative sphere compared with the Online Calculation & Ordering System calculator ( P < .001). For ideal vault, the combination of modified Holladay formula in spherical ICL exhibited highest accuracy ( R = 0.606). For extreme vault, the combination of predicted vault in spherical ICL enhanced R values ( R = 0.864). The combination of predicted vault and modified Holladay formula was most optimal for toric ICL in all ranges of vault (ideal vault: R = 0.516, extreme vault: R = 0.334). CONCLUSIONS The random forest-based calculator, considering vault and variable ocular parameters, illustrated superiority over the existing calculator on the study datasets. Choosing an appropriate lens size to control the vault within the ideal range was helpful to avoid refractive surprises.
Collapse
Affiliation(s)
- Yinjie Jiang
- From the Eye and ENT Hospital, Fudan University, Shanghai, China (Jiang, Shen, X. Chen, Tang, Liu, Zhou, X. Wang); National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China (Jiang, Shen, X. Chen, Tang, Liu, Zhou, X. Wang); Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China (Jiang, Shen, X. Chen, Tang, Liu, Zhou, X. Wang); Beijing Airdoc Technology Co., Ltd., Beijing, China (L. Wang, Ma, Ju, Y. Chen, Ge); Monash Medical AI Group, Monash University, Clayton, Australia (L. Wang, Ju, Ge)
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Kırgız A, Yalçınkaya Çakır G, Çakır İ, Yıldırım Y, Ağca A. Seven-Year clinical outcomes after implantation of Eyecryl posterior chamber phakic intraocular lenses for high myopia. Eur J Ophthalmol 2024:11206721241229311. [PMID: 38297492 DOI: 10.1177/11206721241229311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2024]
Abstract
PURPOSE To evaluate the long-term clinical outcomes, safety and efficacy of Eyecryl posterior-chamber phakic intraocular lens implantation (pIOL) implantation in patients with high myopia. METHODS Patients with myopia between -6.00 and -20.00 dioptres and with endothelial cell density (ECD) was ≥2300 cells/mm2 were included. Preoperative and postoperative first, fourth, and seventh years of refraction, uncorrected/corrected distance visual acuity (UDVA/CDVA), ECD, central vault were detected. RESULTS Thirty-six eyes were analyzed. The mean UDVA and CDVA in postoperative seventh years were 0.25 ± 0.31 and 0.13 ± 0.24 logMAR, respectively. The safety and efficacy indices were 1.55 ± 0.54 and 1.24 ± 0.53, respectively. The mean cumulative ECD loss was 6.96% (p < 0.001). The central vault at the 1st and the 7th year were 0.52 ± 0.14 and 0.49 ± 0.14 mm, respectively (p = 0.25). CONCLUSIONS These findings supported the long-term stability, efficacy, safety of the Eyecryl pIOL for high myopia. Eyecryl posterior chamber pIOL is one of the effective refractive options in correcting high myopia.
Collapse
Affiliation(s)
- Ahmet Kırgız
- University of Health Sciences, Beyoglu Eye Training and Research Hospital, Istanbul, Turkey
| | - Gülay Yalçınkaya Çakır
- University of Health Sciences, Beyoglu Eye Training and Research Hospital, Istanbul, Turkey
| | - İhsan Çakır
- University of Health Sciences, Beyoglu Eye Training and Research Hospital, Istanbul, Turkey
| | - Yusuf Yıldırım
- University of Health Sciences, Beyoglu Eye Training and Research Hospital, Istanbul, Turkey
| | - Alper Ağca
- Atakoy World Eye Hospital, Istanbul, Turkey
| |
Collapse
|
4
|
Naujokaitis T, Auffarth GU, Łabuz G, Khoramnia R. Endothelial Cell Loss in Patients with Phakic Intraocular Lenses. Klin Monbl Augenheilkd 2024. [PMID: 38242162 DOI: 10.1055/a-2209-5251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2024]
Abstract
Although the safety of phakic intraocular lenses (pIOLs) has been continuously improved over 70-years of development, high endothelial cell losses can occur even with current pIOL models. Numerous studies have demonstrated that the distance of a pIOL to the corneal endothelium plays a crucial role in the extent of endothelial cell loss. For this reason alone, higher endothelial cell loss tends to be observed with anterior chamber lenses than with posterior chamber lenses. Adequate preoperative anterior chamber depth is essential, at least for iris-fixed pIOLs, in order to ensure a safe distance from the endothelium. However, the anterior chamber becomes shallower with age and therefore it may be useful to consider patient age in the safety criteria. Although endothelial cell loss is generally low with current pIOL models, regular monitoring of the endothelial cell density remains essential due to large interindividual differences in patients with pIOLs. If the endothelial cell loss is greater than expected and the follow-up visits confirm the trend, the pIOL should be explanted without delay. The endothelial reserve should be considered on an individual basis by taking into account patient age, physiological endothelial cell loss, and loss due to further surgery. With careful indication and long-term patient care, pIOLs remain a safe treatment option.
Collapse
Affiliation(s)
- Tadas Naujokaitis
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, Deutschland
| | - Gerd U Auffarth
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, Deutschland
| | - Grzegorz Łabuz
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, Deutschland
| | - Ramin Khoramnia
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, Deutschland
| |
Collapse
|
5
|
Naujokaitis T, Auffarth GU, Łabuz G, Kessler LJ, Khoramnia R. Diagnostic Techniques to Increase the Safety of Phakic Intraocular Lenses. Diagnostics (Basel) 2023; 13:2503. [PMID: 37568866 PMCID: PMC10417808 DOI: 10.3390/diagnostics13152503] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 07/25/2023] [Accepted: 07/25/2023] [Indexed: 08/13/2023] Open
Abstract
Preoperative and postoperative diagnostics play an important role in ensuring the safety of patients with phakic intraocular lenses (pIOLs). The risk of endothelial cell loss can be addressed by regularly measuring the endothelial cell density using specular microscopy and considering the endothelial cell loss rate and the endothelial reserve in accordance with the patient's age when deciding whether to explant a pIOL. The anterior chamber morphometrics, including the anterior chamber depth and the distance between the pIOL and the endothelium, measured using Scheimpflug tomography and anterior segment optical coherence tomography (AS-OCT), can help to assess the risk of the endothelial cell loss. In patients undergoing posterior chamber pIOL implantation, accurate prediction of the vault and its postoperative measurements using AS-OCT or Scheimpflug tomography are important when assessing the risk of anterior subcapsular cataract and secondary glaucoma. Novel approaches based on ultrasound biomicroscopy and AS-OCT have been proposed to increase the vault prediction accuracy and to identify eyes in which prediction errors are more likely. Careful patient selection and regular postoperative follow-up visits can reduce the complication risk and enable early intervention if a complication occurs.
Collapse
Affiliation(s)
| | | | | | | | - Ramin Khoramnia
- Department of Ophthalmology, University of Heidelberg, 69120 Heidelberg, Germany
| |
Collapse
|
6
|
Di Y, Li Y, Luo Y. Prediction of Implantable Collamer Lens Vault Based on Preoperative Biometric Factors and Lens Parameters. J Refract Surg 2023; 39:332-339. [PMID: 37162400 DOI: 10.3928/1081597x-20230207-03] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
PURPOSE To establish and validate the accuracy of implantable collamer lens (ICL) vault size prediction formula based on preoperative biometric factors and lens parameters. METHODS This study included 300 patients (300 eyes) with Visian ICL V4c (STAAR Surgical) implantation. They were randomly divided into the formula establishment group and formula validation group. Anterior segment measurements, ICL V4c size and power, and vault 1 week postoperatively were collected from all patients. Multiple linear regression analysis was performed to establish the prediction formula. Mean absolute error (MAE), median absolute error (MedAE), root mean square error (RMSE), and Bland-Altman diagrams were used to evaluate the prediction formula. RESULTS Anterior chamber depth (ACD) had the greatest influence on vault 1 week after ICL V4c implantation, followed by ICL V4c size and angle-to-angle distance (ATA). The prediction formula was obtained according to the partial regression coefficient, which was vault (mm) = -1.279 + 0.291 × ACD (mm) + 0.210 × ICL V4c size (mm) - 0.144 × ATA (mm) (R2 = 0.661). In the formula validation group, the mean predictive vault, MAE, MedAE, and RMSE were 628.10, 135.09, 130.42, and 150.46 µm, respectively. The Bland-Altman diagram showed the predictive vault was in good agreement with the actual vault. CONCLUSIONS A novel ICL V4c vault prediction formula was developed and shown to be an effective method for predicting the vault to reduce surgical complications. [J Refract Surg. 2023;39(5):332-339.].
Collapse
|
7
|
Jiang Y, Shen Y, Chen X, Niu L, Li B, Cheng M, Lei Y, Xu Y, Wang C, Zhou X, Wang X. Artificial intelligence-based refractive error prediction and EVO-implantable collamer lens power calculation for myopia correction. EYE AND VISION (LONDON, ENGLAND) 2023; 10:22. [PMID: 37121995 PMCID: PMC10150472 DOI: 10.1186/s40662-023-00338-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 03/16/2023] [Indexed: 05/02/2023]
Abstract
BACKGROUND Implantable collamer lens (ICL) has been widely accepted for its excellent visual outcomes for myopia correction. It is a new challenge in phakic IOL power calculation, especially for those with low and moderate myopia. This study aimed to establish a novel stacking machine learning (ML) model for predicting postoperative refraction errors and calculating EVO-ICL lens power. METHODS We enrolled 2767 eyes of 1678 patients (age: 27.5 ± 6.33 years, 18-54 years) who underwent non-toric (NT)-ICL or toric-ICL (TICL) implantation during 2014 to 2021. The postoperative spherical equivalent (SE) and sphere were predicted using stacking ML models [support vector regression (SVR), LASSO, random forest, and XGBoost] and training based on ocular dimensional parameters from NT-ICL and TICL cases, respectively. The accuracy of the stacking ML models was compared with that of the modified vergence formula (MVF) based on the mean absolute error (MAE), median absolute error (MedAE), and percentages of eyes within ± 0.25, ± 0.50, and ± 0.75 diopters (D) and Bland-Altman analyses. In addition, the recommended spheric lens power was calculated with 0.25 D intervals and targeting emmetropia. RESULTS After NT-ICL implantation, the random forest model demonstrated the lowest MAE (0.339 D) for predicting SE. Contrarily, the SVR model showed the lowest MAE (0.386 D) for predicting the sphere. After TICL implantation, the XGBoost model showed the lowest MAE for predicting both SE (0.325 D) and sphere (0.308 D). Compared with MVF, ML models had numerically lower values of standard deviation, MAE, and MedAE and comparable percentages of eyes within ± 0.25 D, ± 0.50 D, and ± 0.75 D prediction errors. The difference between MVF and ML models was larger in eyes with low-to-moderate myopia (preoperative SE > - 6.00 D). Our final optimal stacking ML models showed strong agreement between the predictive values of MVF by Bland-Altman plots. CONCLUSION With various ocular dimensional parameters, ML models demonstrate comparable accuracy than existing MVF models and potential advantages in low-to-moderate myopia, and thus provide a novel nomogram for postoperative refractive error prediction and lens power calculation.
Collapse
Affiliation(s)
- Yinjie Jiang
- Eye Ear Nose and Throat Hospital, Fudan University, No. 19 BaoQing Road, XuHui District, Shanghai, 200031, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Yang Shen
- Eye Ear Nose and Throat Hospital, Fudan University, No. 19 BaoQing Road, XuHui District, Shanghai, 200031, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xun Chen
- Eye Ear Nose and Throat Hospital, Fudan University, No. 19 BaoQing Road, XuHui District, Shanghai, 200031, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Lingling Niu
- Eye Ear Nose and Throat Hospital, Fudan University, No. 19 BaoQing Road, XuHui District, Shanghai, 200031, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Boliang Li
- Eye Ear Nose and Throat Hospital, Fudan University, No. 19 BaoQing Road, XuHui District, Shanghai, 200031, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Mingrui Cheng
- Eye Ear Nose and Throat Hospital, Fudan University, No. 19 BaoQing Road, XuHui District, Shanghai, 200031, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Yadi Lei
- Eye Ear Nose and Throat Hospital, Fudan University, No. 19 BaoQing Road, XuHui District, Shanghai, 200031, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Yilin Xu
- Eye Ear Nose and Throat Hospital, Fudan University, No. 19 BaoQing Road, XuHui District, Shanghai, 200031, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Chongyang Wang
- Research and Development Department, Shanghai MediWorks Precision Instruments Company Limited, Shanghai, China
| | - Xingtao Zhou
- Eye Ear Nose and Throat Hospital, Fudan University, No. 19 BaoQing Road, XuHui District, Shanghai, 200031, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xiaoying Wang
- Eye Ear Nose and Throat Hospital, Fudan University, No. 19 BaoQing Road, XuHui District, Shanghai, 200031, China.
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China.
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China.
| |
Collapse
|
8
|
Decision taking in corneal refractive surgery. J Cataract Refract Surg 2023; 49:325-330. [PMID: 36867474 DOI: 10.1097/j.jcrs.0000000000001161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Abstract
A 27-year-old woman who wants to get rid of contact lenses and spectacles was seen at our clinic. She had strabismus surgery as a child and was patched for the right eye but now shows mild nondisturbing exophoria. Infrequently, she likes to box in the sports school. Her corrected distance visual acuity at presentation in the right eye was 20/16 with -3.75 -0.75 × 50 and in the left eye 20/16 with -3.75 -1.25 × 142. Her cycloplegic refraction in the right eye was -3.75 -0.75 × 44 and in the left eye was -3.25 -1.25 × 147. The left eye is the dominant eye. The tear break-up time was 8 seconds in both eyes, and the Schirmer tear test was 7 to 10 mm in right and left eyes, respectively. Pupil sizes under mesopic conditions were 6.62 mm and 6.68 mm. The anterior chamber depth (ACD) (measured from the epithelium) in the right eye was 3.89 mm and in the left eye was 3.87 mm. The corneal thickness was 503 μm and 493 μm of the right and left eye, respectively. Corneal endothelial cell density was on average 2700 cells/mm2 for both eyes. Slitlamp biomicroscopy showed clear corneas and a normal flat iris configuration. Supplemental Figures 1 to 4 (available at http://links.lww.com/JRS/A818, http://links.lww.com/JRS/A819, http://links.lww.com/JRS/A820, and http://links.lww.com/JRS/A821) show the corneal topography and Belin-Ambrósio deviation (BAD) maps at presentation of the right eye and left eye, respectively. Would you consider this patient a candidate for corneal refractive surgery (eg, laser-assisted subepithelial keratectomy, laser in situ keratomileusis [LASIK], or small-incision lenticule extraction [SMILE] procedure)? Has your opinion changed given the recent opinion of the U.S. Food and Drug Administration (FDA) regarding LASIK?1 The patient herself is slightly favoring an implantation of a phakic intraocular lens (pIOL), as she prefers something reversible. Would you implant a pIOL, and which type of IOL, for this level of myopia? What is your diagnosis or are additional diagnostic methodologies needed to establish a diagnosis? What is your treatment advice for this patient? REFERENCES 1. U.S. Food and Drug Administration, HHS. Laser-assisted in situ keratomileusis (LASIK) lasers-patient labeling recommendations; draft guidance for industry and food and drug administration staff; availability. July 28, 2022, Federal Register; 87 FR 45334. Available at: https://www.fda.gov/regulatory-information/search-fda-guidance-documents/laser-assisted-situ-keratomileusis-lasik-lasers-patient-labeling-recommendations Accessed January 25, 2023.
Collapse
|
9
|
Zhang W, Li F, Li L, Zhang J. A quantitative study of the effect of ICL orientation selection on post-operative vault and model-assisted vault prediction. Front Neurol 2023; 14:1136579. [PMID: 36937516 PMCID: PMC10020497 DOI: 10.3389/fneur.2023.1136579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 02/14/2023] [Indexed: 03/06/2023] Open
Abstract
Background Appropriate vault height of implantable collamer lens (ICL) implantation matters for it has risks of corneal endothelial cell loss, cataract formation and intraocular pressure elevation, which could lead to irreversible damage to optic nerve. Therefore, pre-operative prediction for an ideal vault height is a hotspot. However, few data exist regarding quantitative effect of ICL orientation on vault height. This study is aimed to quantitatively investigate the effect of ICL implantation orientation on vault height, and built a machine-learning (ML)-based vault prediction model taking implantation orientation into account. Methods 473 consecutive case series treated with ICL implantation were retrospectively analyzed (408 were horizontally implanted, and 65 were vertically implanted). Multivariable logistic regression analysis was performed to determine the association between ICL orientation and achieved vault. ML was performed to develop a new vault height prediction model taking ICL orientation into account. Receiver operating characteristic curve (ROC) and net reclassification index (NRI) were obtained to assess the prediction ability. Results 95% of all the patients achieved 20/20 uncorrected distance visual acuity (UDVA) or better. No complications including cataract formation, dispersion or optic nerve injury were observed in any cases. Sex, sphere power, cylinder power, axis, ICL size and ICL orientation were all significant risk factors associated to vault height, and age was positively co-related. Of note, ICL size and ICL orientation were the top-ranking risk factors. Comparing to conventional horizontal implantation, vertical implantation could reduce the achieved vault by 81.187 μm (p < 0.001). In regarding to different ICL sizes, vertical implantation had no good to vault reduction when using ICL of 12.1 mm. However, it could reduce the vault by 59.351 μm and 160.992 μm respectively when ICL of 12.6mm and 13.2 mm were implanted (p = 0.0097 and p = 0.0124). For prediction of vault height, ML based model significantly outperformed traditional multivariable regression model. Conclusion We provide quantitative evidence that vertical implantation of ICL could effectively reduce the achieved vault height, especially when large size ICL was implanted, comparing to traditional horizontal implantation. ML is extremely applicable in development of vault prediction model.
Collapse
Affiliation(s)
- Weijie Zhang
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
- Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Fang Li
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
- Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Lin Li
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
- Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
- Lin Li
| | - Jing Zhang
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
- Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
- *Correspondence: Jing Zhang
| |
Collapse
|
10
|
Amer AA, Ahmed Ghanem Abu El Wafa Ali E, Sayed Ahmed E, Ateto Hamed M, el Shazly Eata W, Amer I. Posterior-Chamber Phakic Implantable Collamer Lenses with and without a Central Hole: A Comparative Study. Clin Ophthalmol 2023; 17:887-895. [PMID: 36942086 PMCID: PMC10023812 DOI: 10.2147/opth.s405689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 03/13/2023] [Indexed: 03/18/2023] Open
Abstract
Purpose This study aimed to compare the short-term outcome of implanting the Visian implantable collamer lens V4 ICL versus the Visian V4c ICL in patients with moderate and high myopia. Patients and Methods This is a retrospective that was conducted on patients with moderate or high myopia who were scheduled for ICL implantation at our institution, Patients who underwent V4 ICL implantation with peripheral iridectomy were assigned to group A, and those who underwent V4c ICL implantation without peripheral iridectomy were assigned to group B. In group A, a preoperative peripheral iridectomy was performed. In group B, the patients received cycloplegic and dilating agents. The patients underwent a complete ocular examination preoperatively and during the follow-up visits that were conducted at 3, 6, and 12 months postoperatively. Results This study included 214 eyes from 107 patients; group A included 110 eyes, and group B included 104 eyes. Postoperatively, the UCVA and BCVA showed statistically significant improvement across the follow-up time points (p<0.001), with no significant difference between the two groups. No statistically significant difference was found between the two groups in the mean achieved correction or the residual refraction. Both groups showed a strong correlation between the target and the achieved correction, with R2 = 0.99 in the two groups. No significant difference was found between the two groups in the IOP across all time measures. However, the intraocular pressure showed a statistically significant postoperative increase in group A (p=0.004), and no significant change in group B (p=0.817). There was a downward slope in the vaults of both groups across time, with significant variation in the last follow-up measure compared to the 3-month measure in the two groups (p<0.001). No significant difference was found between the two groups across all time measures. Conclusion The current study adds new evidence concerning the feasibility, safety, and efficacy of ICL V4c implantation for the treatment of moderate and high myopia, with safer postoperative IOP.
Collapse
Affiliation(s)
- Ahmed Ali Amer
- Ophthalmology Department, Qena Faculty of Medicine, South Valley University, Qena, Egypt
- Correspondence: Ahmed Ali Amer, Tel +20 101 182 7000, Email
| | | | | | | | - Wael el Shazly Eata
- Ophthalmology Department, Qena Faculty of Medicine, South Valley University, Qena, Egypt
| | - Ibrahim Amer
- Ophthalmology Department, Al Azhar University, Assuit, Egypt
| |
Collapse
|
11
|
Zhang H, Gong R, Zhang X, Deng Y. Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation. Int Ophthalmol 2022; 42:3625-3641. [PMID: 35731355 PMCID: PMC9587946 DOI: 10.1007/s10792-022-02355-w] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Accepted: 04/18/2022] [Indexed: 02/05/2023]
Abstract
PURPOSE To introduce a modified procedure of ICL implantation, to summarize the perioperative problems and their corresponding treatment after myopia correction with Implantable Collamer Lens (ICL), and to compare the difference of complications between the no-hole ICL and hole ICL. METHODS We searched all articles on ICL-related perioperative problems and their corresponding treatment in Scopus, Embase, PubMed and Web of Science databases for the last 22 years. RESULTS ICL implantation is safe, effective, stable and predictable in the correction of myopia, hyperopia and astigmatism, but can also cause a series of perioperative problems, including intraoperative and postoperative complications. CONCLUSION There are many kinds of complications related to ICL, but the common intraoperative and postoperative complications mainly include abnormality of arch height, abnormal position of ICL, loss of corneal endothelial cells and corneal decompensation, high intraocular pressure and secondary glaucoma, cataract and night vision symptoms. Compared with ICL without central pore, the incidence of complications such as loss of corneal endothelial cells and corneal decompensation, high intraocular pressure and secondary glaucoma and cataract was relatively lower in central hole ICL, while postoperative complications such as night vision symptoms were obvious.
Collapse
Affiliation(s)
- Hao Zhang
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| | - Rui Gong
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| | - Xiaolan Zhang
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| | - Yingping Deng
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| |
Collapse
|
12
|
Moshirfar M, Webster CR, Ronquillo YC. Phakic intraocular lenses: an update and review for the treatment of myopia and myopic astigmatism in the United States. Curr Opin Ophthalmol 2022; 33:453-463. [PMID: 35916572 DOI: 10.1097/icu.0000000000000870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
PURPOSE OF REVIEW To review all phakic intraocular lenses (pIOLs) available in the United States for the correction of myopia or myopic astigmatism and offer a clinical approach to their proper use, postoperative follow-up, and analysis of visual and adverse outcomes. RECENT FINDINGS In March 2022, the FDA approved the EVO/EVO+ Visian ICL for widespread use, adding this lens to the two others available (Verisyse, Visian ICL). Cataract formation, endothelial cell loss (ECL) and surgical reintervention remain the most common adverse events. There are discrepancies between studies on ECL following implantation with pIOLs, although trends can be deduced with meta-analysis. Posterior Chamber-pIOLs (PC-pIOLs), especially the EVO/EVO+, have an overall lower mean adverse effect and subjective patient symptom profile when compared to Iris Fixated-pIOLS (IF-pIOLs). Advancements in PC-pIOL sizing have provided a noticeable difference in visual and safety outcomes. SUMMARY All pIOLs available in the United States provide high-quality visual correction of moderate to high myopia and/or myopia with astigmatism. Proper follow-up for ECL and cataract formation is warranted.
Collapse
Affiliation(s)
- Majid Moshirfar
- Hoopes Vision Research Center, Hoopes Vision, Draper
- John A. Moran Eye Center, University of Utah School of Medicine, Salt Lake City
- Utah Lions Eye Bank, Murray, Utah
| | - Court R Webster
- Michigan State University College of Osteopathic Medicine, East Lansing, Michigan, USA
| | | |
Collapse
|
13
|
Packer KT, Vlasov A, Greenburg DL, Coggin A, Weightman JW, Beltran T, Berry-Cabán CS, Carroll RB. U.S. military implantable collamer lens surgical outcomes: 11-year retrospective review. J Cataract Refract Surg 2022; 48:649-656. [PMID: 34653095 DOI: 10.1097/j.jcrs.0000000000000818] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 09/10/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To examine the long-term efficacy and safety of myopic implantable collamer lens (ICL) implantation in active duty personnel of U.S. military. SETTING Hospital practice. DESIGN Retrospective longitudinal observational study. METHODS 1485 patients (median age 25, interquartile range 22 to 29) underwent ICL surgery. Patients received a preoperative examination including uncorrected distance visual acuity (UDVA), intraocular pressure (IOP), manifest refraction measuring corrected distance visual acuity (CDVA), corneal topography and tomography, qualitative grading of perceived ectatic risk, ophthalmic biometry, and baseline endothelial cell counts (ECCs). Outcome measures included UDVA, IOP, vault size, manifest refraction, CDVA, and ECCs. The long-term follow-up data ware drawn from the U.S. military medical record system. RESULTS A total of 3105 eyes were evaluated. Patients received ICLs because of either abnormal topography (2111 eyes [68%]) or high myopia (994 eyes [32%]). 94 eyes (80%) maintained UDVA of 20/25 or better up to 8 years postoperatively. The rate of achieving the desired refractive correction was 97% (503 eyes) at 1 year and 90% (81 eyes) at 8 years. Stability of these outcomes was also shown by minimal change in manifest refraction. Documented mean ECC loss was 22% at postoperative year 5. The overall rate of adverse events was 1.2% (36 eyes) including visually significant cataract formation, glaucoma, retinal detachment, and traumatic incision opening. A removal or replacement rate of 4.5% (135 eyes) was observed. CONCLUSIONS ICL implantation was found to be effective and safe. Vault sizes decreased over time, suggesting an increased risk of cataract formation after 7 years. Further study is necessary to assess long-term clinical significance of ECC decline.
Collapse
Affiliation(s)
- Kyle T Packer
- From the Department of Ophthalmology, Womack Army Medical Center, Fort Bragg, North Carolina (Packer, Vlasov, Greenburg, Coggin, Weightman, Carroll); Department of Clinical Investigation, Womack Army Medical Center, Fort Bragg, North Carolina (Beltran, Berry-Cabán)
| | | | | | | | | | | | | | | |
Collapse
|
14
|
One-year analysis of the refractive stability, axial elongation and related factors in a high myopia population after Implantable Collamer Lens implantation. Int Ophthalmol 2022; 42:3295-3302. [PMID: 35590026 DOI: 10.1007/s10792-022-02328-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Accepted: 04/18/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE To investigate the refractive stability, axial length (AL) changes and their related factors in a high myopia population after Implantable Collamer Lens (ICL) implantation. METHODS This prospective study included 116 eyes of 116 patients divided into several groups based on the spherical equivalent refractive error (SE)-SE > - 6 D, - 12 ≤ SE < - 6 D and SE < - 12 D groups-and AL-AL < 28 mm and AL ≥ 28 mm groups. The uncorrected and corrected distance visual acuity, refraction, AL and intraocular pressure were followed for 1 year. RESULTS SE changed from - 11.53 ± 5.25 D preoperatively to - 0.33 ± 0.70 D at 1 week, and further changed to - 0.48 ± 0.77 D at 1 year after ICL implantation, with average progression being - 0.15 ± 0.37 D from 1 week to 1 year after surgery. AL changed from 27.95 ± 2.33 mm preoperatively to 27.98 ± 2.36 mm 1 year after surgery, with an average axial elongation of 0.03 ± 0.12 mm. The mean axial elongation rate was 0.05 mm/year in the SE < - 12 D group, being significantly faster than the other refractive groups (P < 0.05); it was 0.06 mm/year in the AL ≥ 28 mm group, being significantly faster than the AL < 28 mm group (P < 0.05). CONCLUSION Patients with high myopia and long AL showed a continuous myopic progression and axial elongation at an adult age one year after ICL surgery, especially in those with myopia higher than - 12.00 D and AL longer than 28.00 mm.
Collapse
|
15
|
A Prospective Comparative Study between Implantable Phakic Intraocular Contact Lens and Implantable Collamer Lens in Treatment of Myopia in Adults. J Ophthalmol 2022; 2022:9212253. [PMID: 35388352 PMCID: PMC8979746 DOI: 10.1155/2022/9212253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Revised: 02/07/2022] [Accepted: 03/18/2022] [Indexed: 11/18/2022] Open
Abstract
Purpose To compare implantable collamer lenses (ICLs) and acrylic implantable phakic contact lenses (IPCLs) in the treatment of myopia in adults, as regards refractive outcome and adverse effects. Methods Prospective, randomized comparative study with phakic intraocular lenses (IOLs) was carried out for treatment of myopia. Patients were randomized into two groups: one for ICL and the other for IPCL. Preoperative assessments included a full examination, pentacam, endothelial cell count, and biometry. We compared the adverse effects and refractive outcomes between both groups. The study was registered in clinical trials and the registration number is NCT04624035. Results Sixty eyes of sixty patients (28 in the ICL group and 32 in the IPCL group) with a follow-up period of 12 months. The mean preoperative spherical equivalent was −12.7 ± 3.4 D and −13.6 ± 4.4 D in the ICL and IPCL groups, respectively (P=0.37). The mean postoperative spherical equivalent value was ±0.4 ± 0.2 D and ±0.6 ± 0.1 D in the ICL and IPCL groups, respectively. Uncorrected visual acuity (UCVA) has improved from 1.3 ± 0.06 to 0.15 ± 0.02 Log MAR in the ICL group (P < 0.001) and from 1.3 ± 0.02 to 0.15 ± 0.01 Log MAR in the IPCL group (P < 0.001). The mean endothelial cell count was reduced by 3.3% in the IPCL group and by 3.2% in the IPCL group. Conclusion Both ICL and IPCL are effective methods to correct high myopia in adults with no statistically significant differences between the two lenses as regarding adverse effects.
Collapse
|
16
|
Nonpassopon M, Jongkhajornpong P, Phimpho P, Cheewaruangroj N, Lekhanont K, Chuckpaiwong V. Agreement of implantable collamer lens sizes using parameters from different devices. BMJ Open Ophthalmol 2022; 7:e000941. [PMID: 35372697 PMCID: PMC8905975 DOI: 10.1136/bmjophth-2021-000941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Accepted: 02/25/2022] [Indexed: 11/11/2022] Open
Abstract
Objective To assess agreement and repeatability of white-to-white (WTW) and anterior chamber depth (ACD), and agreement of implantable collamer lens (ICL) size using these measurements from different devices. Methods and analysis A retrospective review of 83 eyes with ICL implantation (42 patients) was conducted. The agreement of WTW (measured with WaveLight Topolyzer and Orbscan IIz) and ACD (measured with WaveLight Oculyzer and Orbscan IIz) was analysed. Correlation of ICL sizes and difference of eyes with unacceptable vaults between two data sets (WaveLight platform; Topolyzer and Oculyzer and Orbscan IIz) were assessed. Results Average WTW measured by Orbscan IIz and Topolyzer demonstrated good agreement (Ρ 0.884) with low systematic bias (−0.03±0.1 mm) and narrow 95% limits of agreement (LoA) of −0.28 to 0.22. Average ACD measured by Orbscan IIz and Oculyzer also showed good agreement (Ρ 0.903) with low systematic bias (−0.04±0.1 mm) and relatively narrow 95% LoA (0.2 to 0.12). ICL size selected according to two data sets showed moderate to strong level of agreement (Kappa=0.81). There was a statistically significant difference (p<0.001) in the proportion of eyes with unacceptable postoperative vaults when using the Wavelight platform data set (five eyes, 6.02%) and the Orbscan IIz data set (12 eyes, 14.46%). Conclusion Although the agreement of WTW and ACD between devices was good, there was a significant difference in proportion of eyes with unacceptable postoperative vaults when using two data sets. Therefore, Topolyzer and Oculyzer might not be suitable for operating interchangeably with Orbscan IIz for ICL size selection.
Collapse
Affiliation(s)
- Manachai Nonpassopon
- Department of Ophthalmology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Passara Jongkhajornpong
- Department of Ophthalmology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Prae Phimpho
- Department of Ophthalmology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Nontawat Cheewaruangroj
- Department of Ophthalmology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Kaevalin Lekhanont
- Department of Ophthalmology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Varintorn Chuckpaiwong
- Department of Ophthalmology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| |
Collapse
|
17
|
Chen Z, Niu L, Zhao J, Yao P, Wang X, Zhou X. One-year Observation of Safety of Implantable Collamer Lens V4c Implantation Without Using an Ophthalmic Viscosurgical Device. Front Med (Lausanne) 2022; 9:790137. [PMID: 35237622 PMCID: PMC8882649 DOI: 10.3389/fmed.2022.790137] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Accepted: 01/24/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose To investigate the feasibility and safety of the implantable collamer lens V4c (ICL V4c) implantation without using an ophthalmic viscosurgical device (OVD-free technique). Methods This prospective consecutive case study enrolled 118 eyes of 60 patients (15 eyes were of male patients, 103 eyes were of female patients, age 26.19 ± 5.03 years, spherical equivalent −10.05 ± 2.73 D). Eyes were considered for OVD-free or OVD-using ICL V4c implantation based on the maintenance of the anterior segment during the surgery. The follow-up lasted for 12 months. The main measurements were visual acuity and changes in endothelial cell density (ECD) at 12 months. Results A total of 75 eyes were included in the OVD-free group and 43 in the OVD group. No infection or other complications were observed in any eye. In the OVD-free group, the safety and efficacy indices were 1.19 ± 0.15 and 1.05 ± 0.20, respectively. 74.5% of the eyes gained one or two lines of corrected distance visual acuity (CDVA), and 25.5% were stable. In the OVD group, the safety and efficacy indices were 1.17 ± 0.17 and 1.03 ± 0.15, respectively; 65.7% of the eyes gained one or two lines of CDVA, and 34.3% were stable. The mean change of ECD was 65.34 cell/ mm2 compared to the baseline in the OVD-free group and 25.94 cell/ mm2 compared to baseline in the OVD group (P = 0.038). Conclusions The ICL V4c implantation with an OVD-free technique is a safe and feasible method in eyes with good maintenance of the anterior segment.
Collapse
Affiliation(s)
- Zhuoyi Chen
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Shanghai, China
- Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Lingling Niu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Shanghai, China
- Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Jing Zhao
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Shanghai, China
- Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Peijun Yao
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Shanghai, China
- Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xiaoying Wang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Shanghai, China
- Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Shanghai, China
- Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- *Correspondence: Xingtao Zhou
| |
Collapse
|
18
|
Evaluation of Visual Outcome of 2 Phakic Posterior Chamber Implantable Lenses in High Myopia: A Comparative Study. Eye Contact Lens 2021; 48:38-44. [PMID: 34775453 DOI: 10.1097/icl.0000000000000854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/09/2021] [Indexed: 10/19/2022]
Abstract
PURPOSE To evaluate and compare the visual outcomes of two phakic intraocular lenses in high myopia. METHODS A prospective comparative study was undertaken on 50 eyes of 26 patients {age ≥21 years and divided into two groups (implantable collamer lens [ICL] V4c, n=25 eyes and refractive implantable lens [RIL], n=25 eyes)}. Patients were evaluated for uncorrected distance visual acuity (UCVA), best-corrected distance visual acuity, manifest refractive spherical equivalent (MRSE), contrast sensitivity, intraocular pressure, dilated fundus examination, trabecular-iris angle (TIA), anterior chamber depth, horizontal white-to-white diameter, wavefront aberrometry, and endothelial cell (EC) count. All patients were followed up until 6 months and additionally evaluated for anterior chamber inflammation, cataract, and lens vault. RESULTS The baseline parameters (UCVA, MRSE, and EC count) and postoperative improvement in UCVA, contrast sensitivity, MRSE, EC loss, safety index, and efficacy index were comparable between both the lenses. The improvement in aberrometric profile was significantly better in the ICL group. The mean postoperative vault was higher in RIL group (434.88±162.48 μm vs. 547.24±159.83 μm, P=0.0173); however, the vault was within normal range in both the groups. The decrease in mean TIA was significantly higher in RIL group (8.58 vs. 13.45 μm, P=0.0073). CONCLUSION Acrylic phakic lens can be considered as a suitable alternative to collamer lens for refractive correction of high myopia. The collamer lenses showed slight superiority in some qualitative visual parameters; however, collamer lenses do not present with subjective complaints in the patients.
Collapse
|
19
|
Long term efficacy and safety profiles following posterior chamber phakic intraocular lens implantation in eyes with ≥ 10-year follow-up. J Cataract Refract Surg 2021; 48:813-818. [PMID: 34670948 DOI: 10.1097/j.jcrs.0000000000000848] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Accepted: 10/13/2021] [Indexed: 11/25/2022]
Abstract
PURPOSE Evaluate long-term efficacy, safety, predictability and stability of a posterior chamber phakic intraocular lens (Visian ICL) in eyes with ≥10-year follow-up. SETTING Instituto de Microcirugía Ocular, Barcelona, Spain. DESIGN Retrospective study. METHODS Eyes undergoing ICL implantation from 2008-2011 with ≥10-year follow-up were included. Variables analyzed were: preoperative, 1-month, 1-year, 5-years and last follow-up uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction, spherical equivalent (SE), endothelial cell count (ECC) and intraocular pressure (IOP). Descriptive statistics were performed and results reported following the Standard for Reporting Refractive Surgery Outcomes. RESULTS 45 eyes (26 patients) were analyzed, mean follow-up 11.35 ± 1.30 years. Mean preoperative SE was -10.06 ± 3.40D and mean preoperative cylinder -1.55 ± 1.45D. At last follow-up, efficacy and safety indices were 0.79 and 1.12, respectively. In total, 32 (71%) eyes achieved an UDVA of ≥20/40. 22 (49%) eyes gained ≥1 line of CDVA, and 2 (4%) eyes lost ≥2 lines of CDVA. At final follow-up, 19 (42%) and 29 (64%) eyes were within ±0.50D and ±1.00D of attempted SE correction, respectively. 31 (69%) eyes had ≤1.00D of postoperative astigmatism and 29 (74%) eyes were within ±15° from the intended correction axis. At the last visit, a statistically significant myopic progression of -0.75 ± 1.20D was observed (p=0.01). ECC loss at last follow-up was 9.85 ± 11.35%. IOP remained stable. There were no intraoperative complications. 3 eyes (7%) developed cataract after 10 years. CONCLUSIONS Long-term results demonstrate that ICL is effective, predictable, stable and safe.
Collapse
|
20
|
Brar S, Gautam M, Sute SS, Pereira S, Ganesh S. Visual and Refractive Outcomes With the Eyecryl Phakic Toric IOL Versus the Visian Toric Implantable Collamer Lens: Results of a 2-Year Prospective Comparative Study. J Refract Surg 2021; 37:7-15. [PMID: 33432990 DOI: 10.3928/1081597x-20201013-04] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Accepted: 10/08/2020] [Indexed: 12/30/2022]
Abstract
PURPOSE To compare the 2-year visual and refractive outcomes with the Eyecryl Phakic Toric IOL (EP TIOL) (Biotech Vision Care Pvt Ltd) and Visian Toric ICL (TICL) (STAAR Surgical) for correction of high myopic astigmatism. METHODS This prospective, interventional, non-randomized comparison study included eligible patients who underwent toric phakic IOL surgery in one or both eyes with either the EP TIOL or TICL for myopic astigmatism. Two years postoperatively, both lenses were compared for their safety, efficacy, stability, and patient satisfaction. Vector analysis of astigmatism was performed using the Alpins method with the ASSORT software (ASSORT Party Ltd). RESULTS A total of 50 eyes were included, of which 25 eyes received EP TIOL implantation and the remaining 25 received TICL implantation. Preoperative mean ± standard deviation of spherical equivalent (SE) and cylinder was -10.15 ± 4.04 and -2.08 ± 0.86 diopters (D) in the EP TIOL group and -10.21 ± 3.97 and -2.17 ± 0.95 D in the TICL group, respectively. At 2 years of follow-up, there was no significant difference between the mean uncorrected distance visual acuity, corrected distance visual acuity, spherical equivalent, and residual astigmatism between the two groups (P > .05 for all parameters). Ninety-two percent of eyes in the EP TIOL group and 88% of eyes in the TICL group were within ±0.50 D of refractive astigmatism. Vector analysis of astigmatism showed a comparable Correction Index of 0.98 in the EP TIOL group and 0.94 in the TICL group, signifying a mild undercorrection of 2% and 6%, respectively. Two eyes in the TICL group underwent exchange for high vault and one eye required realignment due to significant postoperative rotation. CONCLUSIONS At least for the first 2 years postoperatively, both toric phakic IOLs were safe and effective in managing high myopic astigmatism with comparable visual results and patient satisfaction. [J Refract Surg. 2021;37(1):7-15.].
Collapse
|
21
|
Kim BK, Chung YT. Long-term Clinical Outcomes of Implantable Collamer Lens. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2021. [DOI: 10.3341/jkos.2021.62.8.1043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Purpose: To evaluate the long-term clinical outcomes of implantable collamer lens (ICL) implantation in myopic patients.Methods: This retrospective study included 129 eyes of 68 patients who underwent ICL implantation for correction of myopia with a 10-year follow-up.Results: Ten years after ICL implantation, the mean uncorrected and corrected distance visual acuities (LogMAR) were 0.03 ± 0.13 and -0.07 ± 0.06, respectively. Ten years postoperatively, 52.7% and 84.5% of the eyes were within ± 0.5 and ± 1.0 diopters, respectively. The mean efficacy and safety indices were 0.91 ± 0.22 and 1.07 ± 0.19, respectively. There was no significant difference between mean preoperative (13.52 ± 2.88 mmHg) and postoperative (13.59 ± 3.55 mmHg) intraocular pressures. The endothelial cell density decreased from before surgery to 10 years after surgery (3,074 ± 365 cells/mm2, 2,812 ± 406 cells/mm2, respectively; mean decrease: 8.5 ± 10.8%; p = 0.011). Eight eyes (6.2%) developed cataract during follow-up, which was symptomatic in three eyes (2.3%) and treated with ICL explantation and phacoemulsification. Rhegmatogenous retinal detachment occurred in one eye (0.8%) and was treated with vitrectomy.Conclusions: ICL implantation for the correction of myopia had good efficacy and safety outcomes during long-term follow-up of 10 years. However, patients should be closely monitored for complications such as cataract formation, endothelial cell loss, and retinal detachment.
Collapse
|
22
|
Comparative study of small-incision lenticule extraction and phakic intraocular lens implantation for the correction of high myopia: 6-year results. J Cataract Refract Surg 2021; 47:221-226. [PMID: 32925645 DOI: 10.1097/j.jcrs.0000000000000418] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 08/12/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE To compare the long-term safety, efficacy, and complications of small-incision lenticule extraction (SMILE) and flexible iris-fixated anterior chamber phakic intraocular lens (pIOL) implantation for the treatment of high myopia. SETTING University of Health Science Turkey, Beyoğlu Eye Training and Research Hospital, İstanbul, Turkey. DESIGN Retrospective comparative case series. METHODS Data of patients who underwent SMILE or pIOL (Artiflex) implantation for myopia were retrospectively reviewed. Only patients with preoperative manifest refraction spherical equivalent from -6.00 to -10.00 diopters (D) were included in the study. RESULTS There were 47 eyes of 32 patients in the SMILE group and 52 eyes of 29 patients in the pIOL group. The mean postoperative follow-up was 63.75 ± 18.40 months in the SMILE group and 65.38 ± 16.22 months in the p-IOL group (P = .71). At 6 years postoperatively, refractive predictability was slightly better in the pIOL group, and the percentages of eyes within ±0.50 D of the attempted correction were 77% and 83% in the SMILE and pIOL groups, respectively. Although mean uncorrected distance visual acuity was comparable (SMILE, 0.12 ± 0.06 logarithm of the minimum angle of resolution [logMAR]; p-IOL, 0.09 ± 0.05 logMAR), the safety indices (1.08 ± 0.22 vs 1.11 ± 0.20; P = .02) and the efficacy indices (0.92 ± 0.24 vs 1.11 ± 0.22; P = .03) were statistically significantly higher after pIOL implantation. Despite a mean of 11.09% of the endothelial cell being lost at 6 years after pIOL implantation, no pIOL was explanted due to endothelial cell loss. CONCLUSIONS In this comparative and long-term study, iris-fixated anterior chamber pIOL implantation for high myopic correction showed slightly better safety and efficacy profiles but with statistically significant endothelial cell loss.
Collapse
|
23
|
Use of neural networks to predict vault values after implantable collamer lens surgery. Graefes Arch Clin Exp Ophthalmol 2021; 259:3795-3803. [PMID: 34313826 PMCID: PMC8589809 DOI: 10.1007/s00417-021-05294-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 06/03/2021] [Accepted: 06/21/2021] [Indexed: 11/22/2022] Open
Abstract
Background Appropriate sizing of the implantable collamer lens (ICL) and accurate prediction of the vault are crucial prior to surgery. However, sometimes, the vault value is higher or lower than predicted, necessitating reoperation. The present study aimed to develop neural networks for improving predictions of vault values following ICL implantation based on preoperative biometric data. Methods This retrospective study included 137 eyes of 74 patients with ICLs. Linear regression and neural network analyses were used to examine the relationship between vault values at the 6-month follow-up and preoperative parameters (e.g., ICL characteristics and biometrics). Results Linear regression analysis revealed that vault values were correlated with five variables: ICL size, anterior chamber depth (ACD), angle-to-angle (ATA), white-to-white (WTW), and lens thickness (LT) (adjusted R2 = 0.411). Inclusion of more input variables was associated with better performance in the neural network analysis. The degree of fit when all 11 variables were included in the neural network model was close to 1 (R2 = 0.98). R2 values for the quaternary neural network model enrolling four input variables (ICL size, ATA, ACD, and LT) reached 0.90. Conclusions A neural network equation including the ICL size and biometric parameters of the anterior segment (ATA, ACD, and LT) can be used to predict the postoperative vault, aiding in the selection of an appropriate ICL size and reducing the need for reoperation after surgery.![]() Supplementary Information The online version contains supplementary material available at 10.1007/s00417-021-05294-x.
Collapse
|
24
|
Barros L, Sena N, Motta C, Criado G, Ambrósio R. Lentes intraoculares fácicas para miopia e astigmatismo: revisão prospectiva. REVISTA BRASILEIRA DE OFTALMOLOGIA 2021. [DOI: 10.37039/1982.8551.20210012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
25
|
Yang W, Zhao J, Zhao J, Shen Y, Niu L, A R, Wang X, Zhou X. Changes in anterior lens density after Implantable Collamer Lens V4c implantation: a 4-year prospective observational study. Acta Ophthalmol 2021; 99:326-333. [PMID: 32840066 DOI: 10.1111/aos.14584] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Revised: 07/11/2020] [Accepted: 07/12/2020] [Indexed: 12/11/2022]
Abstract
PURPOSE To investigate the changes in anterior lens density with a Pentacam after Implantable Collamer Lens (ICL) V4c implantation in patients with myopia. METHODS This prospective case series examined 62 eyes of 32 patients (mean age, 28.5 ± 5.73 years) with myopia or myopic astigmatism after ICL V4c implantation. Uncorrected distance vision acuity, corrected distance vision acuity (CDVA), manifest refraction, intraocular pressure, anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), endothelial cell density and Pentacam images of lens density were obtained pre- and postoperatively. The vault was obtained during the follow-ups. RESULTS Patients were followed up for an average of 51 ± 2.7 months (range, 48-57 months). All surgeries were uneventful, without any complication. The efficacy and safety indices at the last follow-up were 1.03 ± 0.2 and 1.22 ± 0.22, respectively. No eye had decreased CDVA, and 66% eyes gained ≥1 line. Furthermore, refractive error in 90% eyes was within ±0.50 D and that of 100% was within ±1.0 D of the attempted refraction. Anterior average lens density (a-ALD) in the 0.5-, 1.0- and 1.5-mm depth zones increased by 10.41 ± 11.51%, 17.1 ± 11.09% and 16.76 ± 10.4%, respectively, compared to preoperative values (all p < 0.05). The change in a-ALD between two different age groups was not significant. Moreover, there were no significant correlations between the change in a-ALD and age, preoperative spherical equivalent, ACD, ACA, ACV or vault. CONCLUSIONS Implantable Collamer Lens (ICL) V4c implantation demonstrates safety and efficacy for myopia correction. Although a-ALD increased slightly at 4 years postoperatively, no cataract developed during the follow-up. Further studies should investigate the reason for the postoperative increase in a-ALD.
Collapse
Affiliation(s)
- Wen Yang
- Department of Ophthalmology The Third People's Hospital of Chengdu The Affiliated Hospital of Southwest Jiaotong University Chengdu China
| | - Jing Zhao
- Department of Ophthalmology Eye and ENT Hospital of Fudan University NHC Key Laboratory of Myopia Laboratory of Myopia Chinese Academy of Medical Sciences Shanghai China
| | - Jiao Zhao
- Department of Ophthalmology People's Hospital of Leshan Leshan China
| | - Yang Shen
- Department of Ophthalmology Eye and ENT Hospital of Fudan University NHC Key Laboratory of Myopia Laboratory of Myopia Chinese Academy of Medical Sciences Shanghai China
| | - Lingling Niu
- Department of Ophthalmology Eye and ENT Hospital of Fudan University NHC Key Laboratory of Myopia Laboratory of Myopia Chinese Academy of Medical Sciences Shanghai China
| | - Ruma A
- Department of Ophthalmology Eye and ENT Hospital of Fudan University NHC Key Laboratory of Myopia Laboratory of Myopia Chinese Academy of Medical Sciences Shanghai China
| | - Xiaoying Wang
- Department of Ophthalmology Eye and ENT Hospital of Fudan University NHC Key Laboratory of Myopia Laboratory of Myopia Chinese Academy of Medical Sciences Shanghai China
| | - Xingtao Zhou
- Department of Ophthalmology Eye and ENT Hospital of Fudan University NHC Key Laboratory of Myopia Laboratory of Myopia Chinese Academy of Medical Sciences Shanghai China
| |
Collapse
|
26
|
Zhao J, Yang W, Zhao J, Shen Y, Sun L, Han T, Wang X, Yao P, Zhou X. A four-year observation of corneal densitometry after implantable collamer lens V4c implantation. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:536. [PMID: 33987234 DOI: 10.21037/atm-20-6628] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background To observe the changes in corneal densitometry (CD) with a Pentacam after implantable collamer lens (ICL) V4c implantation in myopia patients, and to investigate potential influencing factors. Methods We reviewed 65 eyes of 33 patients (mean age, 29.08±5.54 years) with myopia or myopic astigmatism who underwent ICL V4c implantation. Clinic parameters and Pentacam images of corneal topography and CD were obtained pre- and postoperatively. Results After an average of 52±2.2 months follow-up, the efficacy and safety indexes assessed at the last follow-up were 1.03±0.18 and 1.21±0.21, respectively. Except in the central annular zone of 0-2 mm, the CD values increased significantly at postoperative day 1 and decreased significantly until postoperative 1 year (P<0.05). The increase in CD values at different annular zones at postoperative day 1 was ranked as: 0-2 mm <2-6 mm < 6-10 mm. No significant difference was observed in corneal density at 1 week, 1 month, and 1-year follow-up when compared with the preoperative value (P>0.05). The CD value at 4 years follow-up increased significantly and correlated positively with age and preoperative uncorrected distance visual acuity, and negatively with preoperative spherical equivalent and intraocular pressure (IOP) (P<0.05). Conclusions ICL V4c implantation demonstrated safety and efficacy for myopia correction. The CD value increased at 4 years postoperatively and correlated with age, preoperative spherical equivalent, uncorrected distance visual acuity, and IOP.
Collapse
Affiliation(s)
- Jing Zhao
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Wen Yang
- Department of Ophthalmology, The Third People's Hospital of Chengdu, The Affiliated Hospital of Southwest Jiaotong University, Chengdu, China
| | - Jiao Zhao
- Department of Ophthalmology, People's Hospital of Leshan, Leshan, China
| | - Yang Shen
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Ling Sun
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Tian Han
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xiaoying Wang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Peijun Yao
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| |
Collapse
|
27
|
Posterior chamber phakic intraocular lens for the correction of presbyopia in highly myopic patients. J Cataract Refract Surg 2021; 46:40-44. [PMID: 32050231 DOI: 10.1097/j.jcrs.0000000000000033] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To report the initial experience with a new presbyopic phakic intraocular lens (pIOL) in the correction of high myopia and presbyopia. SETTING Gemini Eye Clinic, Zlin, Czech Republic. DESIGN Prospective cohort study. METHODS Presbyopic eyes with moderate to high myopia were implanted with a presbyopic posterior chamber pIOL (IPCL). The visual acuities at near and distance, endothelial cell density, and ocular condition were examined 1 week, 3 months, 1 year and 2 years postoperatively. RESULTS The mean uncorrected distance visual acuity improved significantly from 1.25 logarithm of the minimum angle of resolution (logMAR) (1.15 to 1.35 95% confidence interval [CI]) to 0.11 logMAR (95% CI, 0.03 to 0.17) (P < .0001). No eye lost 1 or more lines of corrected distance visual acuity. The mean distance refraction improved significantly from -6.9 diopters (D) (range -8.6 to -5.3 D) preoperatively to -0.35 D (range -0.55 to -0.15 D, P < .0001) with less than -0.5 D residual refraction in 11 of 17 eyes. Fifteen of 17 eyes had improved uncorrected near visual acuity to J1 (Jaeger chart) at the 2-year follow-up. The near addition at the 2-year follow-up decreased from preoperatively +1.26 D (range 0.19 to 2.34 D) to +0.39 D (range 0.18 to 0.60 D). The mean endothelial cell density was reduced from 2552 cells/mm (range 2421 to 2682 cells/mm) to 2299 cells/mm (range 2108 to 2490 cells/mm) after 2 years. All patients were subjectively satisfied with the outcomes. CONCLUSIONS The new pIOL provided good visual outcomes in near and far distances in an initial case series of patients.
Collapse
|
28
|
Hu R, Xu W, Huang B, Wang X. Ex-PRESS shunt implantation for intractable glaucoma with posterior chamber phakic intraocular lens: a case report. BMC Ophthalmol 2021; 21:20. [PMID: 33413216 PMCID: PMC7791721 DOI: 10.1186/s12886-020-01784-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Accepted: 12/21/2020] [Indexed: 11/17/2022] Open
Abstract
Background Implantation of the posterior chamber phakic intraocular lens has been widely performed to correct high and extreme myopia. Chronic intraocular pressure (IOP) elevation may occur in its late postoperative period. For medically uncontrolled cases, surgical treatment is necessary, and benefits should be weighed against risks when determining whether to remove the lens. Case presentation A 32-year-old man with extremely high myopia presented with progressive blurred vision and medically uncontrolled IOP in the right eye. His past ocular history was significant for bilateral implantable collamer lens (ICL) implantation ten years ago. On ophthalmic examination, the ICL was well placed with a vault height of 456 µm in the right eye. The anterior chamber angles were open but narrow, and mild to moderate trabecular pigmentation was noted. Ex-PRESS glaucoma filtration surgery without ICL removal was performed to control IOP. During surgery, an Ex-PRESS P50 shunt was inserted into the anterior chamber via the front edge of the blue-grey transition zone between the sclera and cornea. Transient hypotony and shallow anterior chamber occurred in the first week after surgery, along with an ICL tilt towards the cornea with reduced vault height. No other complications related to either the ICL or the Ex-PRESS shunt were noted. IOP remained stable at 12 ~ 14 mmHg at the first 3-month follow-up. Conclusions Ex-PRESS glaucoma filtration surgery might be a safe and effective alternative treatment for intractable glaucoma with high myopia and ICL implantation. Careful assessment of the ICL position and anterior chamber angle is necessary to plan the appropriate surgical procedure. A postoperative shallow anterior chamber may result in ICL dislocation.
Collapse
Affiliation(s)
- Rongrong Hu
- Department of Ophthalmology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Wei Xu
- Department of Ophthalmology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Baishuang Huang
- Department of Ophthalmology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Xiaoyu Wang
- Department of Ophthalmology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
| |
Collapse
|
29
|
Abstract
Myopia, also known as short-sightedness or near-sightedness, is a very common condition that typically starts in childhood. Severe forms of myopia (pathologic myopia) are associated with a risk of other associated ophthalmic problems. This disorder affects all populations and is reaching epidemic proportions in East Asia, although there are differences in prevalence between countries. Myopia is caused by both environmental and genetic risk factors. A range of myopia management and control strategies are available that can treat this condition, but it is clear that understanding the factors involved in delaying myopia onset and slowing its progression will be key to reducing the rapid rise in its global prevalence. To achieve this goal, improved data collection using wearable technology, in combination with collection and assessment of data on demographic, genetic and environmental risk factors and with artificial intelligence are needed. Improved public health strategies focusing on early detection or prevention combined with additional effective therapeutic interventions to limit myopia progression are also needed.
Collapse
|
30
|
Deshpande K, Shroff R, Biswas P, Kapur K, Shetty N, Koshy AS, Khamar P. Phakic intraocular lens: Getting the right size. Indian J Ophthalmol 2020; 68:2880-2887. [PMID: 33229663 PMCID: PMC7856930 DOI: 10.4103/ijo.ijo_2326_20] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Phakic intraocular lenses (IOL) are a boon for patients who want spectacle independence but are unable to get refractive correction through laser platforms due to high refractive error or certain corneal contraindications. Phakic IOL's (PIOL) have their own set of complications and challenges, the most important being getting the sizing right. This paper attempts to solve the problem of accurate sizing of PIOL's. Parameters needed for calculating the ideal size of PIOL's have been studied in a step by step manner using all possible tools depending upon the availability and preference of the surgeon. The pros and cons of using a particular tool for measurements have been highlighted along with illustrative case examples to help surgeons who are starting PIOL implantation surgery.
Collapse
Affiliation(s)
- Kalyaani Deshpande
- Department of Cataract and Refractive Surgery, Mumbai Eye, Brain and Spine Clinic, Mumbai, Maharashtra, India
| | - Rushad Shroff
- Department of Cataract, Cornea, and Refractive Surgery, Shroff Eye Centre, New Delhi, India
| | - Partha Biswas
- Department of Cataract and Refractive Surgery, Director, B B Eye Foundation, Kolkata, West Bengal, India
| | - Kamal Kapur
- Department of Cataract and Refractive Surgery, Director, Sharp Sight Laser Centre Pvt Ltd, New Delhi, India
| | - Naren Shetty
- Department of Cataract and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India
| | - Ann Sarah Koshy
- Department of Cataract and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India
| | - Pooja Khamar
- Department of Cataract and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India
| |
Collapse
|
31
|
Kohnen T, Maxwell A, Holland S, Lane S, Von Tress M, Salem C, LaFontaine L. Ten-year safety follow-up and post-explant analysis of an anterior chamber phakic IOL. J Cataract Refract Surg 2020; 46:1457-1465. [PMID: 33149065 DOI: 10.1097/j.jcrs.0000000000000351] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To assess endothelial cell loss (ECL) rate and collect safety data in patients with AcrySof L-series Cachet phakic intraocular lens (pIOL) up to 10 years post-implantation. SETTING Clinical settings in the United States, European Union, and Canada. DESIGN Nonrandomized, observational, open-label safety study. METHODS Central and peripheral endothelial cell density was evaluated and compared with 6-month post-implantation baseline. Nonlinear analysis was performed to identify factors affecting post-explantation ECL. Additional evaluations included uncorrected visual acuity (UCVA), corrected distance visual acuity (CDVA), adverse device effects (ADEs), and serious adverse events (SAEs). RESULTS The study included 1123 implanted eyes (mean age, 37.5 years). At 10 years, mean central and peripheral ECL was 16% (1.7% annualized). Explantations were performed in 10% of eyes (n = 136/1323). For eyes with pIOL explantation because of ECL (7%), annualized ECL rate post-explantation was numerically lower compared with the overall rate in eyes that underwent explantation for any reason (annualized rate, -1.65% vs -2.03%, respectively; n = 96) and compared with pre-explantation ECL. Mean ± SD CDVA and UCVA were -0.12 ± 0.11 and 0.03 ± 0.22 logarithm of the minimum angle of resolution, respectively. Common ocular ADEs included ECL (10%), pIOL extraction (9%), iris adhesion (7%), and pupillary deformity (2%). Common SAEs included pIOL extraction (11%), ECL (9%), and iris adhesions (8%). CONCLUSIONS Cachet pIOLs were associated with long-term ECL in some cases. Overall, only 10% of all implanted eyes underwent explantation during 10-year follow-up. In patients requiring explantation because of ECL, the annualized ECL rates decreased post-explantation in some eyes. Continued monitoring of patients regardless of explantation is recommended.
Collapse
Affiliation(s)
- Thomas Kohnen
- From the Department of Ophthalmology, Goethe-University (Kohnen), Frankfurt, Germany; California Eye Institute (Maxwell), Fresno, California, USA; Department of Ophthalmology, University of British Columbia (Holland), Vancouver, Pacific Laser Eye Centre (Holland), Vancouver, British Columbia, Canada; Associated Eye Care, University of Minnesota (Lane), Stillwater, Minnesota, and Alcon Research LLC (Lane, Von Tress, Salem, LaFontaine), Fort Worth, Texas, USA
| | | | | | | | | | | | | |
Collapse
|
32
|
Nakamura T, Isogai N, Kojima T, Yoshida Y, Sugiyama Y, Tanaka Y, Ichikawa K. Long-term In Vivo Stability of Posterior Chamber Phakic Intraocular Lens: Properties and Light Transmission Characteristics of Explants. Am J Ophthalmol 2020; 219:295-302. [PMID: 32622670 DOI: 10.1016/j.ajo.2020.06.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Revised: 06/19/2020] [Accepted: 06/21/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE To evaluate the in vivo durability of the surface and optical properties of the implantable Collamer lens (ICL). DESIGN Retrospective case series. METHODS We included patients who developed cataracts after having undergone ICL implantation from March 2003 to May 2014 and underwent ICL explantation followed by cataract surgery from March 2017 to December 2019 at the Nagoya Eye Clinic. ICL explants were submitted to Chukyo Medical Co, Ltd (Nagoya City, Japan) for laboratory analysis using ultraviolet-visible light spectroscopy, light microscopy (LM), and scanning electron microscopy. Patients' demographic and clinical data were collected and reviewed. RESULTS Thirteen eyes from 10 patients were studied. The average age at ICL explantation was 50.5 ± 8.5 years (range, 34.5-66.3 years). The average length of ICL stay in the eye (from implantation to explantation) was 10.5 ± 2.7 years (range, 4.4-13.7 years). No opacification or coloring of the ICL explants was observed by LM. The ICL explants showed almost the same light transmittance as that of unused ICLs. Scanning electron microscopy revealed no irregularities at the surface of the center and periphery of the optic and haptic footplate. The positioning holes did not show any deposition. CONCLUSION The ICLs remained in-eye for >10 years without any deterioration in the surface and optical properties of the ICL, despite their contact with the ciliary body and iris tissues and the continuous interaction with the aqueous humor components. The present study shows long-term in vivo stability of the ICL.
Collapse
|
33
|
Zhang J, He F, Liu Y, Fan X. Implantable collamer lens with a central hole for residual refractive error correction after corneal refractive surgery. Exp Ther Med 2020; 20:160. [PMID: 33093898 PMCID: PMC7571336 DOI: 10.3892/etm.2020.9289] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Accepted: 09/11/2020] [Indexed: 11/06/2022] Open
Abstract
The present study aimed to assess the visual and refractive outcomes of an implantable collamer lens with a central hole (ICL V4c) for residual refractive error correction after corneal refractive surgery in individuals with myopia. A total of 16 eyes of eight consecutive patients with myopia undergoing ICL V4c implantation after corneal refractive surgery were investigated. The uncorrected visual acuity (VA) and best-corrected VA were examined prior to surgery and at 1, 3 and 6 months after surgery. The post-operative values of the modulation transfer function (MTF) cutoff frequency, Strehl ratio (SR), objective scattering index (OSI) and Optical Quality Analysis System (OQAS) values (OVs) were quantitatively assessed using an OQAS. At 6 months after surgery, the mean uncorrected LogMAR VA was 0.06±0.10 and the values had improved in 100% of the eyes. The mean MTF cutoff frequency, SR, OSI, OV 100%, OV 20% and OV 9%, were 31.294±4.321 cycles/degree, 0.187±0.039, 1.399±0.274, 1.066±0.261, 0.748±0.287 and 0.509±0.229, respectively. In conclusion, ICL V4c implantation for the correction of residual refractive error after corneal refractive surgery appeared feasible and safe and also had an excellent optical performance. However, long-term changes in visual quality require further investigation.
Collapse
Affiliation(s)
- Jing Zhang
- Department of Ophthalmology, Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, P.R. China
| | - Fanglin He
- Department of Ophthalmology, Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, P.R. China
| | - Yan Liu
- Department of Ophthalmology, Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, P.R. China
| | - Xianqun Fan
- Department of Ophthalmology, Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, P.R. China
| |
Collapse
|
34
|
Chen H, Feng X, Niu G, Fan Y. Evaluation of Dry Eye after Implantable Collamer Lens Surgery. Ophthalmic Res 2020; 64:356-362. [PMID: 32966980 DOI: 10.1159/000511197] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 08/23/2020] [Indexed: 11/19/2022]
Abstract
OBJECTIVES To evaluate dry eye (DE) and associated meibomian gland dysfunction parameters after Implantable Collamer Lens (ICL) surgery. METHODS This is a prospective observational case series. Patients who underwent ICL implantation without previous ocular diseases or ophthalmic treatments were enrolled. Their Ocular Surface Disease Index (OSDI), noninvasive breakup time (NIBUT), meibography, slit-lamp examination of the lid margin, corneal fluorescein staining (CFS), and Schirmer test I were examined preoperatively and at 1 and 3 months postoperatively. RESULTS A total of 117 eyes of 60 patients were enrolled, and 107 eyes completed 3-month follow-up period. OSDI, lid marginal abnormality, and meibomian gland (MG) secretion, and meibum quality score were significantly higher at 1 month postoperatively and recovered partially at 3 months after surgeries, while NIBUT was significantly decreased all the time. Patients with previous DE symptoms (OSDI score ≥12) showed not only lower Schirmer and TBUT values but also higher CFS, lid margin score, MG loss, MG secretion, and meibum quality scores compared with those in the control group after operations. Low Schirmer, NIBUT values, and high meibum quality score were determined as risk factors for DE symptoms after ICL surgery. CONCLUSIONS ICL implantation has a bad influence on the ocular surface and MG functions. The influence may be more obvious in patients with existing DE.
Collapse
Affiliation(s)
- Haiting Chen
- Department of Ophthalmology, Cangzhou Central Hospital, Cangzhou, China
| | - Xueyan Feng
- Department of Ophthalmology, Cangzhou Central Hospital, Cangzhou, China
| | - Guangzeng Niu
- Department of Ophthalmology, Cangzhou Central Hospital, Cangzhou, China
| | - Yuxiang Fan
- Department of Ophthalmology, Cangzhou Central Hospital, Cangzhou, China,
| |
Collapse
|
35
|
Hernández-Rodríguez CJ, Piñero DP. A systematic review about the impact of phakic intraocular lenses on accommodation. JOURNAL OF OPTOMETRY 2020; 13:139-145. [PMID: 31937486 PMCID: PMC7301210 DOI: 10.1016/j.optom.2019.08.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2018] [Revised: 07/26/2019] [Accepted: 08/12/2019] [Indexed: 06/10/2023]
Abstract
Phakic intraocular lenses (pIOL) are the main treatment for patients who have either high ametropia or contraindications for laser refractive surgery. The main feature that makes this kind of lenses suitable for its implantation in young adults searching for independence of optical prescription is the conservation of accommodation, since lens extraction is not required. A systematic review has been performed to evaluate the scientific literature on the effect of pIOL implantation on accommodation. Critical assessment of the articles included in the review was achieved using the tool Critical Appraisal Skills Programme in its Spanish form (CASPe). After revising the complete text of 10 articles pre-selected, two quasi-experimental pre-post studies evaluating the outcomes of a specific model of posterior chamber pIOL were included in the systematic review. The CASPe scoring of both studies were 5/11. According to this outcome, the evidence describing the impact of the pIOL implantation on the accommodative function can be defined poor. Some trends are reported as the decrease in the amplitude of accommodation, a decrease positive relative accommodation and improvement of accommodation. However, these results should be confirmed in future controlled studies.
Collapse
Affiliation(s)
- Carlos J Hernández-Rodríguez
- Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, Spain
| | - David P Piñero
- Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, Spain.
| |
Collapse
|
36
|
Yang W, Zhao J, Sun L, Zhao J, Niu L, Wang X, Zhou X. Four-year observation of the changes in corneal endothelium cell density and correlated factors after Implantable Collamer Lens V4c implantation. Br J Ophthalmol 2020; 105:625-630. [PMID: 32546550 PMCID: PMC8077217 DOI: 10.1136/bjophthalmol-2020-316144] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Revised: 05/11/2020] [Accepted: 05/25/2020] [Indexed: 11/23/2022]
Abstract
Background To evaluate the changes in corneal endothelium cell density (ECD) and the correlated factors after Implantable Collamer Lens (ICL) V4c implantation. Methods In this retrospective, consecutive study, 48 eyes of 25 patients with myopia who underwent ICL V4c implantation were enrolled. Patients were followed up for at least 4 years, during which manifest refraction, uncorrected distance visual acuity, corrected distance visual acuity (CDVA), intraocular pressure, ECD, anterior chamber depth, anterior chamber volume (ACV), anterior chamber angle (ACA), vault and distance from the corneal endothelium to the central ICL (C-ICL) were measured. Spearman’s correlation analysis was used to identify variables correlated with changes in ECD, and generalised estimating equation model adjusting within-patient intereye correlations was used to predict changes in ECD. Results All surgeries were performed safely with no complications during follow-up (average 52±2.9 months). Safety and efficacy indices were 1.23±0.22 and 1.04±0.16, respectively. No eyes had decreased CDVA, and 67% gained one or more lines. Further, 79% were within ±0.50 D, and 100% were within ±1.0 D of the attempted refraction. Additionally, a 4.03%±2.2% reduction in ECD compared with the preoperative value was observed at the last follow-up visit. Changes in ECD were significantly correlated with vault, C-ICL, change in ACA and change in ACV. Vault was the most significant factor for changes in ECD. Conclusions ICL V4c implantation is safe and effective for myopia correction. Anterior segment biometric parameters including the vault, ACA and C-ICL may influence changes in ECD; specifically, the vault plays a major role.
Collapse
Affiliation(s)
- Wen Yang
- Department of Ophthalmology, The Third People's Hospital of Chengdu, The Affiliated Hospital of Southwest Jiaotong University, Chengdu, China
| | - Jing Zhao
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University; NHC Key Laboratory of Myopia; Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| | - Ling Sun
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University; NHC Key Laboratory of Myopia; Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| | - Jiao Zhao
- Department of Ophthalmology, People's Hospital of Leshan, Leshan, China
| | - Lingling Niu
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University; NHC Key Laboratory of Myopia; Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| | - Xiaoying Wang
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University; NHC Key Laboratory of Myopia; Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| | - Xingtao Zhou
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University; NHC Key Laboratory of Myopia; Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| |
Collapse
|
37
|
Peng M, Tang Q, Zhao L, Khan MA, Lin D. Safety of implantable Collamer lens implantation without ophthalmic viscosurgical device: A retrospective cohort study. Medicine (Baltimore) 2020; 99:e20691. [PMID: 32541520 PMCID: PMC7302580 DOI: 10.1097/md.0000000000020691] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
To compare the safety of implantable Collamer lens (ICL) implantation with and without ophthalmic viscosurgical device (OVD).A total of 148 eyes underwent a conventional ICL implantation with OVD (OVD group), and 112 eyes underwent a modified ICL implantation without OVD (OVD-free group). The balanced salt solution was used to load ICL and maintain the anterior chamber in the OVD-free group. The surgical time, postoperative uncorrected distance visual acuity, intraocular pressure, endothelial cell density (ECD), and percentage of hexagonal cells were compared between the OVD and the OVD-free groups.No significant differences were detected in uncorrected distance visual acuity, intraocular pressure, ECD, and percentage of hexagonal cells at any time post-surgery between the 2 groups (P > .05). The mean ECD loss was 1.9% in the OVD-free group and 2.3% in the OVD group at 2 years post-surgery (P = .680). The surgical time was much shorter in the OVD-free group than that in the OVD group (P ≤ .001). None of the following occurred at any time during the 2-year follow-up period in both groups: cataract formation, macular degeneration, or any other vision-threatening complications.OVD-free ICL implantation presented satisfactory results for safety. Compared to OVD, the OVD-free technique had the advantages of decreased surgical time, increased efficiency, and reduced cost.
Collapse
Affiliation(s)
- Manqiang Peng
- Central South University Aier School of Ophthalmology
- Changsha Aier Eye Hospital, Changsha, China
| | - Qiongyan Tang
- Central South University Aier School of Ophthalmology
- Changsha Aier Eye Hospital, Changsha, China
| | - Libei Zhao
- Central South University Aier School of Ophthalmology
- Changsha Aier Eye Hospital, Changsha, China
| | - Muhanmad Ahmad Khan
- Central South University Aier School of Ophthalmology
- Changsha Aier Eye Hospital, Changsha, China
| | - Ding Lin
- Central South University Aier School of Ophthalmology
- Changsha Aier Eye Hospital, Changsha, China
| |
Collapse
|
38
|
Kayhan B, Coskunseven E, Sahin O, Pallikaris I. The effects of implantable collamer lens implantation on higher order aberrations. Int J Ophthalmol 2019; 12:1848-1852. [PMID: 31850167 DOI: 10.18240/ijo.2019.12.05] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Accepted: 04/30/2019] [Indexed: 11/23/2022] Open
Abstract
AIM To evaluate the changes in higher order aberrations (HOAs) after implantable collamer lens (ICL; Staar Surgical, Nidau, Switzerland) implantation. METHODS Totally 30 eyes of 18 patients with myopia were included in this study with an average age of 25.77y (min: 21, max: 40). Refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), HOAs (entire, corneal and internal) were evaluated preoperatively and three months postoperatively. Ocular aberrations were measured by using iTrace (Tracey Technology, Houston, Texas, USA). SPSS (IBM Corp. Released 2013. IBM SPSS Statistics for Windows, Version 22.0. Armonk, NY: IBM Corp) was used for the statistical analysis and the interpretation of the data. P values of less than 0.05 were considered statistically significant. RESULTS The preoperative mean spherical power was -9.01 D (min: -5.00, max: -13.00) and the mean cylindrical error was -2.40 D (min: -0.50, max: -4.75). The postoperative mean residual spherical power was -0.73 D (min: -0.20, max: -1.75) and the mean cylindrical error was -0.89 D (min: -0.18, max: -2.09). Analyses were made on root mean square (RMS) values of total HOAs (tHOAs), spherical aberration, coma and trefoil as entire, corneal and internal components. The differences in entire tHOAs and in internal tHOAs were significant. There was no significant change found in spherical aberrations. The differences in entire coma and in internal coma were significant. There was no significant change found in corneal coma. With respect to trefoil, the only significant difference was in internal trefoil. CONCLUSION The ICL implantation corrects the refractive error successfully and changes entire and internal HOAs of the eye.
Collapse
Affiliation(s)
- Belma Kayhan
- Dunyagoz Hospital Group, Istanbul 34337, Turkey.,Department of Ophthalmology, Sultan Abdulhamid Han Training and Research Hospital, the University of Saglik Bilimleri, Istanbul 34668, Turkey
| | | | - Onurcan Sahin
- Dunyagoz Hospital Group, Istanbul 34337, Turkey.,Institute of Vision and Optics, University of Crete, Heraklion 70013, Greece
| | - Ioannis Pallikaris
- Dunyagoz Hospital Group, Istanbul 34337, Turkey.,Institute of Vision and Optics, University of Crete, Heraklion 70013, Greece
| |
Collapse
|
39
|
Choi JH, Lim DH, Nam SW, Yang CM, Chung ES, Chung TY. Ten-year clinical outcomes after implantation of a posterior chamber phakic intraocular lens for myopia. J Cataract Refract Surg 2019; 45:1555-1561. [DOI: 10.1016/j.jcrs.2019.06.015] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2019] [Revised: 06/08/2019] [Accepted: 06/17/2019] [Indexed: 11/25/2022]
|
40
|
Nakamura T, Isogai N, Kojima T, Yoshida Y, Sugiyama Y. Posterior Chamber Phakic Intraocular Lens Implantation for the Correction of Myopia and Myopic Astigmatism: A Retrospective 10-Year Follow-up Study. Am J Ophthalmol 2019; 206:1-10. [PMID: 31078536 DOI: 10.1016/j.ajo.2019.04.024] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Revised: 04/10/2019] [Accepted: 04/23/2019] [Indexed: 11/16/2022]
Abstract
PURPOSE To assess the 10-year clinical outcomes of implantable collamer lens (ICL) implantation for myopia and astigmatism. DESIGN Retrospective observational case series. METHODS This study included 114 eyes of 61 patients who underwent ICL implantation for correction of myopia and myopic astigmatism. We assessed the safety, efficacy, predictability, stability, and adverse events preoperatively, at 6 months (106 eyes) and 1 (94 eyes), 3 (58 eyes), 5 (65 eyes), 8 (89 eyes), and 10 (70 eyes) years postoperatively. Only the eyes with clinical data available at each follow-up time were analyzed. RESULTS The mean logMAR uncorrected and corrected distance visual acuities were -0.01 ± 0.24 and -0.18 ± 0.07 at 10 years postsurgery. The mean indices for safety and efficacy were 0.88 ± 0.15 and 0.66 ± 0.26, respectively. At 10 years postsurgery, 71.4% and 87.1% of the eyes were within 0.5 and 1.0 diopters (D), respectively, of the attempted spherical equivalent correction. The mean intraocular pressure was 13.1 ± 2.4 mmHg preoperatively and 13.1 ± 2.9 mmHg at 10 years postoperatively. The mean endothelial cell loss was 5.3% at 10 years postsurgery. Twelve of 114 eyes (10.5%) developed anterior subcapsular cataract during 5-10 years' follow-up; among these, 4 eyes (3.5%) were symptomatic and ICL explantation and phacoemulsification surgery were performed. No vision-threatening complications occurred during the observation period. CONCLUSION ICL implantation offered good overall outcomes in all measures of safety, efficacy, predictability, and stability for the correction of myopia and myopic astigmatism throughout a long-term follow-up period of 10 years.
Collapse
Affiliation(s)
| | | | - Takashi Kojima
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| | | | | |
Collapse
|
41
|
Kook D, Mayer WJ, Steinwender G, Kohnen T. Phake Hinterkammerlinsen. SPEKTRUM DER AUGENHEILKUNDE 2019. [DOI: 10.1007/s00717-019-00438-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
42
|
Zhu Y, Yue Y, Zhu H, Chen J, Zhou J. Influence of refractive error on pupil diameters in highly myopic eyes with implantable collamer lenses. Eur J Ophthalmol 2019; 30:1328-1334. [PMID: 31304777 DOI: 10.1177/1120672119863716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To investigate the influence of refractive error on pupil diameters in highly myopic eyes with implantable collamer lenses. SETTING Shanghai, China. DESIGN A prospective consecutive observational study. METHODS Sixty-six eyes of 66 patients that underwent ICL V4c implantation were included. Pupil diameters before and 1 week, 1 month, and 3 months after surgery were measured using an automatic pupillometry system (MonCv3; Metrovision, Pérenchies, France) under four standardized illumination conditions: 0, 1, 10, and 100 cd/m2. The correlations between changes in pupil diameter and spherical equivalent values and patient age were investigated. RESULTS Based on preoperative spherical equivalent values, included eyes were divided into a high-myopia group (-6.3 to -9.9 D (diopters)) and a super-high-myopia group (-10 to -20 D). Pupil sizes remained unchanged after surgery in the high-myopia group and decreased at 1 and 10 cd/m2 in the super-high-myopia group. A between-group comparison showed that pupils were significantly smaller in the super-high-myopia group 1 week postoperatively under all illumination conditions and remained smaller at 1 month and 3 months under 1 and 10 cd/m2 lighting conditions. Preoperative spherical equivalent values were significantly correlated with the percent decrease in pupil diameter 1 week postoperatively under 0, 1, and 10 cd/m2 illumination conditions; the greater the degree of myopia, the greater the reduction in pupil diameter. CONCLUSION Preoperative refractive error significantly affects pupil diameter in highly myopic eyes after implantable collamer lens implantation. Pupils of super highly myopic eyes remained smaller than preoperative levels under mesopic conditions after implantable collamer lens implantation.
Collapse
Affiliation(s)
- Yi Zhu
- Department of Ophthalmology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Yu Yue
- Department of Ophthalmology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Haobin Zhu
- Department of Ophthalmology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Jili Chen
- Department of Ophthalmology, Shibei Hospital, Shanghai, China
| | - Jibo Zhou
- Department of Ophthalmology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| |
Collapse
|
43
|
Zhu Y, He T, Zhu H, Chen J, Zhou J. Static and dynamic pupillary characteristics in high myopic eyes with two implantable collamer lenses. J Cataract Refract Surg 2019; 45:946-951. [DOI: 10.1016/j.jcrs.2019.01.027] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Revised: 01/23/2019] [Accepted: 01/23/2019] [Indexed: 11/27/2022]
|
44
|
Predictability of the vault after posterior chamber phakic intraocular lens implantation using anterior segment optical coherence tomography. J Cataract Refract Surg 2019; 45:1099-1104. [PMID: 31174990 DOI: 10.1016/j.jcrs.2019.02.020] [Citation(s) in RCA: 71] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Revised: 02/08/2019] [Accepted: 02/14/2019] [Indexed: 11/23/2022]
Abstract
PURPOSE To determine whether vault measurements after placement of a hole implantable collamer lens (hole ICL) (KS-AquaPORT) can be predicted by angle-to-angle (ATA) and white-to-white (WTW) measurements obtained with anterior segment optical coherence tomography (AS-OCT). SETTING Sanno Hospital, Tokyo, Japan. DESIGN Retrospective case series. METHODS Eyes were observed for 3 months after hole ICL implantation for myopia or myopic astigmatism. Central vault, ATA, and WTW measurements were obtained before and after surgery using the swept-source AS-OCT CASIA2 system. RESULTS The study included 44 eyes (23 patients). The mean patient age and preoperative spherical equivalent, ATA, and WTW values were 36.2 years ± 8.8 (SD), -6.23 ± 3.41 diopters (D), 12.03 ± 0.40 mm, and 11.72 ± 0.40 mm, respectively. The safety index and efficacy index 3 months postoperatively were 1.13 ± 0.21 and 0.91 ± 0.30, respectively. Regarding predictability, 93.2% of eyes were within ±0.50 D of the attempted correction and all eyes were within ±1.00 D. The reproducibility coefficients for the ATA distance and WTW distance were 0.998 and 0.960, respectively. The mean postoperative central vault was 491.6 ± 189.5 μm. There was a significant correlation between postoperative vault and the ICL size and ATA distance (Spearman rank correlation coefficient r = 0.59, P < .001) but not between the ICL size and WTW distance (r = 0.27, P = .08). CONCLUSION The ATA measurements had higher reproducibility than the WTW measurements on AS-OCT, making it is a more important predictor of postoperative vault.
Collapse
|
45
|
Zhu Y, Zhang J, Zhu H, Chen J, Zhou J. The effect of mydriasis on moderate-to-high myopic eyes with implantable collamer lenses V4 and V4c. Eur J Ophthalmol 2019; 30:462-468. [PMID: 30845836 DOI: 10.1177/1120672119831218] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To evaluate the vault change and anterior segment movement induced by mydriasis in moderate-to-high myopic eyes with implantable collamer lenses (ICL). SETTING Shanghai, China. DESIGN A prospective consecutive observational study. METHODS A total of 45 eyes of 24 patients with ICL V4 implantation and 128 eyes of 65 patients with ICL V4c implantation were included and analyzed. Anterior chamber depth, posterior corneal endothelium-to-ICL distance, and vault before and after mydriasis were measured by Pentacam (Oculus, Wetzlar, Germany) at 1, 3, and 6 months after surgery. RESULTS Significant vault increases and anterior chamber depth increases induced by mydriasis were noted in both ICL V4 and V4c groups at 1, 3, and 6 months postoperatively. The corneal endothelium-ICL distance increased significantly in eyes with implanted ICL V4c after mydriasis at 3 and 6 months. Moreover, mydriasis-induced vault increases were greater in the ICL V4 group than in the ICL V4c group at 3 and 6 months. In eyes with implanted ICL V4c, mydriasis-induced vault increases were significantly greater at 1 month than at 3 and 6 months. CONCLUSION Mydriasis results in a general vault increase in eyes with implanted ICLs. The adjustment of the pressure equilibrium via the central hole of the ICL V4c has an important role in vault change. The mydriasis-induced vault increases tend toward stability after 3 months postoperatively. Mydriasis is relatively safe in eyes with ICL implantation.
Collapse
Affiliation(s)
- Yi Zhu
- Department of Ophthalmology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Jing Zhang
- Department of Ophthalmology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Haobin Zhu
- Department of Ophthalmology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Jili Chen
- Department of Ophthalmology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.,Department of Ophthalmology, Shibei Hospital, Shanghai, China
| | - Jibo Zhou
- Department of Ophthalmology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| |
Collapse
|
46
|
|
47
|
Sachdev G, Ramamurthy D. Long-term safety of posterior chamber implantable phakic contact lens for the correction of myopia. Clin Ophthalmol 2019; 13:137-142. [PMID: 30662257 PMCID: PMC6327895 DOI: 10.2147/opth.s185304] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Purpose To review the safety of the implantable phakic contact lens (IPCL V1, Caregroup Sight Solutions, India) for correction of myopia and myopic astigmatism. Methods Retrospective interventional case series including 134 eyes which underwent IPCL implantation for correction of myopia and myopic astigmatism at a tertiary eye care hospital in South India. Intraoperative and postoperative complications were analyzed. The following parameters were analyzed at preoperative and 1, 6 and 12 month postoperative visits: visual acuity (in logMAR) and manifest refraction, slit lamp bio microscopy, dilated fundus examination, IOP and endothelial cell density measurement. Results No intraoperative complications were noted. Cataract was the most common postoperative complication, wherein three eyes (2.2%) underwent observation for visually insignificant anterior subcapsular cataract and one eye (0.7%) required surgical intervention. Four eyes developed transient increased IOP due to steroid response (3 eyes) and pupillary block glaucoma (1 eye). The endothelial cell loss noted over a 1-year follow-up was 2.01%±4.12% (P=0.71). One eye developed hypopyon on the third postoperative day, which resolved subsequently with an unaided vision of 20/20. No vision threatening complications were noted. The mean follow-up in the cohort was 25.66±16.45 months. Conclusion The IPCL is a safe and effective treatment modality for correction of myopia and myopic astigmatism.
Collapse
|
48
|
Subramanian S, Vadivelu S, Babu MA, Meenakshi B, Santhosh J. A study on the safety and efficacy of posterior chamber phakic intraocular lens (refractive implantable lens) in high myopia. TNOA JOURNAL OF OPHTHALMIC SCIENCE AND RESEARCH 2019. [DOI: 10.4103/tjosr.tjosr_45_19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
49
|
Fernández-Vega-Cueto L, Lisa C, Esteve-Taboada JJ, Montés-Micó R, Alfonso JF. Implantable collamer lens with central hole: 3-year follow-up. Clin Ophthalmol 2018; 12:2015-2029. [PMID: 30349185 PMCID: PMC6188208 DOI: 10.2147/opth.s171576] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Purpose To evaluate the long-term predictability, stability, safety, and efficacy of the V4c Visian implantable collamer lens (ICL) with central hole to correct myopia. Patients and methods One hundred and eighty-four eyes of 92 patients were evaluated during 3 years after implantation of the V4c ICL. The refraction, uncorrected distance visual acuity, best-corrected distance visual acuity, IOP, endothelial cell count, vault, and adverse effects were evaluated every 12 months during the whole follow-up. Results The mean spherical equivalent dropped from -8.30±2.98 D preoperatively to −0.37±0.47 D at 36 months post-surgery, with 91.8% eyes being within ±1.00 D of emmetropia. With respect to the astigmatic components J0 and J45, 98.4% and 99.5% of eyes, respectively, were within ±0.50 D of the desired refraction. At 36 months, 78.8% of eyes had no change in the Snellen lines of best-corrected distance visual acuity, while 8.7% gained one line and 6.5% gained two or more lines; mean safety and efficacy indexes were 1.03 and 0.90, respectively. Mean endothelial cell count was 2,742±340 cells/mm2 before and 2,663±366 cells/mm2 at 36 months post-surgery. Mean IOP reduced from 13.7±1.9 mmHg preoperatively to 12.8±1.7 mmHg at 36 months post-surgery. Mean vault varied from 409±196 µm at 12 months to 349±165 µm at 36 months. Conclusion The visual and refractive outcomes were very good and highly stable throughout the follow-up period, indicating that this ICL model may be predictable, stable, safe, and effective to correct myopia in the long term.
Collapse
Affiliation(s)
| | - Carlos Lisa
- Department of Surgery, Fernández-Vega Ophthalmological Institute, Oviedo, Spain,
| | - José J Esteve-Taboada
- Department of Optics and Optometry and Visual Sciences, University of Valencia, Valencia, Spain
| | - Robert Montés-Micó
- Department of Optics and Optometry and Visual Sciences, University of Valencia, Valencia, Spain
| | - José F Alfonso
- Department of Surgery, Fernández-Vega Ophthalmological Institute, Oviedo, Spain, .,School of Medicine, University of Oviedo, Oviedo, Spain,
| |
Collapse
|
50
|
Prospective Randomized Multicenter Comparison of the Clinical Outcomes of V4c and V5 Implantable Collamer Lenses: A Contralateral Eye Study. J Ophthalmol 2018; 2018:7623829. [PMID: 30254757 PMCID: PMC6145048 DOI: 10.1155/2018/7623829] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2018] [Revised: 07/28/2018] [Accepted: 08/02/2018] [Indexed: 11/17/2022] Open
Abstract
Purpose To compare the visual and refractive outcomes and night vision performance questionnaire results between V4c and V5 implantable Collamer lenses in a prospective, randomized, multicenter study. Settings Four refractive surgery centers. Design Prospective randomized multicenter single-masked comparative study. Methods Twenty-three patients were enrolled in this study. A conventional V4c model (EVO Visian ICL) was implanted in one eye, and a V5 model (EVO+ Visian ICL), which has a larger optic diameter than the V4c model, was implanted in the contralateral eye. The uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were evaluated before and 6 months after surgery. At 6 months after surgery, a questionnaire on night vision disturbances was administered. The efficacy, safety, and predictability of the two implanted ICL models were compared. Results There were no significant differences in the postoperative UDVA and CDVA between the two ICL models. The mean efficacy indexes for the V4c and V5 lenses were 1.16 ± 0.22 and 1.03 ± 0.23, respectively. The mean safety indexes of the V4c and V5 lenses were 1.21 ± 0.20 and 1.19 ± 0.20, respectively. The night vision performance questionnaire revealed that 7 patients (37%) noticed a difference in visual performance between the eyes, and all of them reported that they could see better at night with the V5-implanted eye compared with the V4c-implanted eye. Conclusion The V4c and V5 ICL models achieved similar visual and refractive outcomes, whereas the V5 model showed a possible advantage in reducing night vision disturbances.
Collapse
|