1
|
Gulati K, Chopra D, Kocak-Oztug NA, Verron E. Fit and forget: The future of dental implant therapy via nanotechnology. Adv Drug Deliv Rev 2023; 199:114900. [PMID: 37263543 DOI: 10.1016/j.addr.2023.114900] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 05/11/2023] [Accepted: 05/21/2023] [Indexed: 06/03/2023]
Abstract
Unlike orthopedic implants, dental implants require the orchestration of both osseointegration at the bone-implant interface and soft-tissue integration at the transmucosal region in a complex oral micro-environment with ubiquitous pathogenic bacteria. This represents a very challenging environment for early acceptance and long-term survival of dental implants, especially in compromised patient conditions, including aged, smoking and diabetic patients. Enabling advanced local therapy from the surface of titanium-based dental implants via novel nano-engineering strategies is emerging. This includes anodized nano-engineered implants eluting growth factors, antibiotics, therapeutic nanoparticles and biopolymers to achieve maximum localized therapeutic action. An important criterion is balancing bioactivity enhancement and therapy (like bactericidal efficacy) without causing cytotoxicity. Critical research gaps still need to be addressed to enable the clinical translation of these therapeutic dental implants. This review informs the latest developments, challenges and future directions in this domain to enable the successful fabrication of clinically-translatable therapeutic dental implants that would allow for long-term success, even in compromised patient conditions.
Collapse
Affiliation(s)
- Karan Gulati
- The University of Queensland, School of Dentistry, Herston, QLD 4006, Australia.
| | - Divya Chopra
- The University of Queensland, School of Dentistry, Herston, QLD 4006, Australia
| | - Necla Asli Kocak-Oztug
- The University of Queensland, School of Dentistry, Herston, QLD 4006, Australia; Istanbul University, Faculty of Dentistry, Department of Periodontology, 34116 Istanbul, Turkey
| | - Elise Verron
- Nantes Université, CNRS, CEISAM, UMR 6230, 44000 Nantes, France
| |
Collapse
|
2
|
Graphene-Doped Polymethyl Methacrylate (PMMA) as a New Restorative Material in Implant-Prosthetics: In Vitro Analysis of Resistance to Mechanical Fatigue. J Clin Med 2023; 12:jcm12041269. [PMID: 36835805 PMCID: PMC9960587 DOI: 10.3390/jcm12041269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 01/26/2023] [Accepted: 02/01/2023] [Indexed: 02/09/2023] Open
Abstract
BACKGROUND AND PURPOSE Provisional prostheses in restorations over several implants with immediate loading in completely edentulous patients increase the risk of frequent structural fractures. An analysis was performed of the resistance to fracture of prosthetic structures with cantilevers using graphene-doped polymethyl methacrylate (PMMA) resins and CAD-CAM technology. METHODS A master model was produced with four implants measuring 4 mm in diameter and spaced 3 mm apart, over which 44 specimens representing three-unit fixed partial prostheses with a cantilever measuring 11 mm were placed. These structures were cemented over titanium abutments using dual cure resin cement. Twenty-two of the 44 units were manufactured from machined PMMA discs, and 22 were manufactured from PMMA doped with graphene oxide nanoparticles (PMMA-G). All of the samples were tested in a chewing simulator with a load of 80 N until fracture or 240,000 load applications. RESULTS The mean number of load applications required for temporary restoration until the fracture was 155,455 in the PMMA-G group versus 51,136 in the PMMA group. CONCLUSIONS Resistance to fracture under cyclic loading was three times greater in the PMMA-G group than in the PMMA group.
Collapse
|
3
|
Enhanced Corrosion Resistance and Local Therapy from Nano-Engineered Titanium Dental Implants. Pharmaceutics 2023; 15:pharmaceutics15020315. [PMID: 36839638 PMCID: PMC9963924 DOI: 10.3390/pharmaceutics15020315] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 01/12/2023] [Accepted: 01/12/2023] [Indexed: 01/19/2023] Open
Abstract
Titanium is the ideal material for fabricating dental implants with favorable biocompatibility and biomechanics. However, the chemical corrosions arising from interaction with the surrounding tissues and fluids in oral cavity can challenge the integrity of Ti implants and leach Ti ions/nanoparticles, thereby causing cytotoxicity. Various nanoscale surface modifications have been performed to augment the chemical and electrochemical stability of Ti-based dental implants, and this review discusses and details these advances. For instance, depositing nanowires/nanoparticles via alkali-heat treatment and plasma spraying results in the fabrication of a nanostructured layer to reduce chemical corrosion. Further, refining the grain size to nanoscale could enhance Ti implants' mechanical and chemical stability by alleviating the internal strain and establishing a uniform TiO2 layer. More recently, electrochemical anodization (EA) has emerged as a promising method to fabricate controlled TiO2 nanostructures on Ti dental implants. These anodized implants enhance Ti implants' corrosion resistance and bioactivity. A particular focus of this review is to highlight critical advances in anodized Ti implants with nanotubes/nanopores for local drug delivery of potent therapeutics to augment osseo- and soft-tissue integration. This review aims to improve the understanding of novel nano-engineered Ti dental implant modifications, focusing on anodized nanostructures to fabricate the next generation of therapeutic and corrosion-resistant dental implants. The review explores the latest developments, clinical translation challenges, and future directions to assist in developing the next generation of dental implants that will survive long-term in the complex corrosive oral microenvironment.
Collapse
|
4
|
PEREA-LOWERY L, GIBREEL M, VALLITTU PK, LASSILA L. Characterization of the mechanical properties of CAD/CAM polymers for interim fixed restorations. Dent Mater J 2020; 39:319-325. [DOI: 10.4012/dmj.2019-042] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Leila PEREA-LOWERY
- Department of Biomaterials Science and Turku Clinical Biomaterials Center–TCBC, Institute of Dentistry, University of Turku
| | - Mona GIBREEL
- Department of Biomaterials Science and Turku Clinical Biomaterials Center–TCBC, Institute of Dentistry, University of Turku
| | - Pekka K. VALLITTU
- Department of Biomaterials Science and Turku Clinical Biomaterials Center–TCBC, Institute of Dentistry, University of Turku
- City of Turku Welfare Division, Oral Health Care
| | - Lippo LASSILA
- Department of Biomaterials Science and Turku Clinical Biomaterials Center–TCBC, Institute of Dentistry, University of Turku
| |
Collapse
|
5
|
A Systematic Review of Survival Rates of Osseointegrated Implants in Fully and Partially Edentulous Patients Following Immediate Loading. J Clin Med 2019; 8:jcm8122142. [PMID: 31817177 PMCID: PMC6947536 DOI: 10.3390/jcm8122142] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 11/27/2019] [Accepted: 12/02/2019] [Indexed: 12/30/2022] Open
Abstract
Background: The aim of this systematic review was to evaluate the survival rates of immediately loaded implants after at least five years. Besides implant failure, the amount of marginal bone loss around implants and the complication type were assessed. Methods: The electronic search was undertaken on Medline, Scopus, and Cochrane Central Register of Controlled Trials using key terms such as: “immediate loading”, “immediate function”, “immediate restoration”, “immediate temporization”, “dental implants”, “fully edentulous patients”, “partially edentulous patients”. The search terms were combined using the Boolean operators AND, OR. The last electronic search was performed on 15 February 2018. Two authors independently screened the studies, extracted the data, and assessed the risk-of bias. The main outcomes recorded for each study were: implant and prosthesis success and survival, marginal bone level change, incidence and type of complications. Kaplan–Meier analysis was used to estimate cumulative survival rates. Results: Thirty-four prospective studies with at least five-year follow-up, published between 2007 and 2017 were included. A total of 5349 immediately loaded implants in 1738 patients were analyzed. The mean follow-up was 72.4 months (median 60 months, 95% confidence intervals (CI): 64.53, 80.25 months, range 60 to 147 months). The mean weighted implant survival was 97.4% (median 98.15%, 95% CI: 96.29%, 98.54%, range 83.80% to 100%). Cumulative survival rate of implants placed in the mandible was significantly higher than for the maxilla (p < 0.01). No significant difference in failure rate was found among the types of prosthesis employed (p = 0.27). The mean peri-implant bone level change at the end of the follow-up in each study ranged from 0.3 to 1.7 mm. Conclusion: Immediate loading of implants appears to have long-term predictability and success rate under well-defined circumstances.
Collapse
|
6
|
Abstract
The oral cavities of tobacco smokers and users of smokeless tobacco products are exposed to high concentrations of nicotine. A limited number of animal studies have assessed the effect of nicotine on osseointegration. Results from experimental studies have reported a statistically significant decrease, at 4 weeks of follow-up, in bone-to-implant contact among rats exposed to nicotine compared with unexposed rats. Nicotine increases the production of inflammatory cytokines (such as interleukin-6 and tumor necrosis factor-alpha) by osteoblasts. Waterpipe, pipe, and cigarette smokers are at increased risk of developing oral cancer, periodontal disease, and alveolar bone loss. One explanation for this is that smokers (regardless of the type of tobacco product) are exposed to similar chemicals, such as nicotine, tar, oxidants, polyaromatic hydrocarbons, and carbon monoxide. Moreover, raised levels of proinflammatory cytokines have been identified in the gingival crevicular fluid of cigarette smokers with peri-implant diseases. Therefore, it is hypothesized that nicotine and chemicals in tobacco smoke induce a state of oxidative stress in peri-implant tissues (gingiva and alveolar bone), thereby increasing the likelihood of peri-implant disease development via an inflammatory response, which if left uncontrolled, will result in implant failure/loss. In this regard, tobacco smoking (including cigarettes, waterpipe, and pipe) is a significant risk factor for peri-implant diseases. The impact of vaping electronic cigarettes using nicotine-containing e-juices remains unknown. Habitual use of smokeless tobacco products is associated with oral inflammatory conditions, such as oral precancer, cancer, and periodontal disease. However, the effect of habitual use of smokeless tobacco products on the success and survival of dental implants remains undocumented.
Collapse
Affiliation(s)
- Fawad Javed
- Eastman Institute of Oral Health, University of Rochester, Rochester, NY, USA
| | - Irfan Rahman
- Department of Environmental Medicine, University of Rochester Medical Center, Rochester, New York, USA
| | - Georgios E Romanos
- Eastman Institute of Oral Health, University of Rochester, Rochester, NY, USA
- Department of Oral Surgery and Implant Dentistry, Dental School, Johann Wolfgang Goethe University, Frankfurt, Germany
| |
Collapse
|
7
|
Daudt Polido W, Aghaloo T, Emmett TW, Taylor TD, Morton D. Number of implants placed for complete‐arch fixed prostheses: A systematic review and meta‐analysis. Clin Oral Implants Res 2018; 29 Suppl 16:154-183. [DOI: 10.1111/clr.13312] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Revised: 05/03/2018] [Accepted: 05/28/2018] [Indexed: 11/29/2022]
Affiliation(s)
- Waldemar Daudt Polido
- Department of Oral and Maxillofacial SurgeryIndiana University School of Dentistry Indianapolis Indiana
| | - Tara Aghaloo
- Department of Oral and Maxillofacial SurgeryUCLA School of Dentistry Los Angeles California
| | - Thomas W. Emmett
- Ruth Lilly Medical LibraryIndiana University School of Medicine Indianapolis Indiana
| | - Thomas D. Taylor
- Department of Reconstructive SciencesUniversity of Connecticut School of Dental Medicine Farmington Connecticut
| | - Dean Morton
- Department of ProsthodonticsIndiana University School of Dentistry Indianapolis Indiana
| |
Collapse
|
8
|
Yilmaz B, Alp G, Seidt J, Johnston WM, Vitter R, McGlumphy EA. Fracture analysis of CAD-CAM high-density polymers used for interim implant-supported fixed, cantilevered prostheses. J Prosthet Dent 2018; 120:79-84. [PMID: 29310879 DOI: 10.1016/j.prosdent.2017.09.017] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2017] [Revised: 09/25/2017] [Accepted: 09/25/2017] [Indexed: 10/18/2022]
Abstract
STATEMENT OF PROBLEM The load-to-fracture performance of computer-assisted design and computer-assisted manufacturing (CAD-CAM) high-density polymer (HDP) materials in cantilevers is unknown. PURPOSE The purposes of this in vitro study were to evaluate the load-to-fracture performance of CAD-CAM-fabricated HDPs and to compare that with performance of autopolymerized and injection-molded acrylic resins. MATERIAL AND METHODS Specimens from 8 different brands of CAD-CAM HDPs, including Brylic Solid (BS); Brylic Gradient (BG); AnaxCAD Temp EZ (AE); AnaxCAD Temp Plus (AP); Zirkonzahn Temp Basic (Z); GDS Tempo-CAD (GD); Polident (Po); Merz M-PM-Disc (MAT); an autopolymerized acrylic resin, Imident (Conv) and an injection-molded acrylic resin, SR-IvoBase High Impact (Inj) were evaluated for load-to-fracture analysis (n=5). CAD-CAM specimens were milled from poly(methyl methacrylate) (PMMA) blocks measuring 7 mm in buccolingual width, 8 mm in occlusocervical thickness, and 30 mm in length. A wax pattern was prepared in the same dimensions used for CAD-CAM specimens, flasked, and boiled out. Autopolymerizing acrylic resin was packed and polymerized in a pressure container for 30 minutes. An identical wax pattern was flasked and boiled out, and premeasured capsules were injected (SR-IvoBase) and polymerized under hydraulic pressure for 35 minutes for the injection-molded PMMA. Specimens were thermocycled 5000 times (5°C to 55°C) and fixed to a universal testing machine to receive static loads on the 10-mm cantilever, vertically at a 1 mm/min crosshead speed until fracture occurred. Maximum load-to-fracture values were recorded. ANOVA was used to analyze the maximum force values. Significant differences among materials were analyzed by using the Ryan-Einot-Gabriel-Welsch multiple range test (α=.05). RESULTS Statistically significant differences were found among load-to-fracture values of different HDPs (P<.001). GD and Po materials had significantly higher load-to-fracture values than other materials (P<.001), and no statistically significant differences were found between GD and Po. The lowest load-to-fracture values were observed for autopolymerized and BG materials, which were significantly lower than those of GD, Po, AE, AP, Z, MAT, Inj, and BS. The load-to-fracture value of autopolymerized acrylic resin was not significantly different from that of BG CAD-CAM polymer. CONCLUSIONS GD and Po CAD-CAM materials had the highest load-to-fracture values. AE, AP, Z, MAT, and BS CAD-CAM polymers and injection-molded acrylic resin had similar load-to-fracture values, which were higher than those of BG and autopolymerized acrylic resin. Autopolymerized acrylic resin load-to-fracture value was similar to that of BG CAD-CAM polymer, which is colored in a gradient pattern.
Collapse
Affiliation(s)
- Burak Yilmaz
- Associate Professor, Division of Restorative Science and Prosthodontics, College of Dentistry, The Ohio State University, Columbus, Ohio.
| | - Gülce Alp
- Former Visiting Professor, The Ohio State University, College of Dentistry, Restorative Science and Prosthodontics, Columbus, Ohio; and Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Okan University, Istanbul, Turkey
| | - Jeremy Seidt
- Research Scientist, Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, Ohio
| | - William M Johnston
- Professor Emeritus, Division of General Practice and Materials Science, The Ohio State University, College of Dentistry, Columbus, Ohio
| | | | - Edwin A McGlumphy
- Professor, Division of Restorative Science and Prosthodontics, The Ohio State University, College of Dentistry, Columbus, Ohio
| |
Collapse
|
9
|
Doornewaard R, Christiaens V, De Bruyn H, Jacobsson M, Cosyn J, Vervaeke S, Jacquet W. Long-Term Effect of Surface Roughness and Patients' Factors on Crestal Bone Loss at Dental Implants. A Systematic Review and Meta-Analysis. Clin Implant Dent Relat Res 2016; 19:372-399. [PMID: 27860171 DOI: 10.1111/cid.12457] [Citation(s) in RCA: 69] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Publications from 2011 to 2015 were selected to evaluate effect of implant surface roughness on long-term bone loss as surrogate for peri-implantitis risk. 87 out of 2,566 papers reported the mean bone loss after at least 5 years of function. Estimation of the proportion of implants with bone loss above 1, 2, and 3 mm as well as analysis the effect of implant surface roughness, smoking, and history of periodontitis was performed. By means of the provided statistical information of bone loss (mean and standard deviation) the prevalence of implants with bone loss ranging from 1 to 3 mm was estimated. The bone loss was used as a surrogate parameter for "peri-implantitis" given the fact that "peri-implantitis" prevalence was not reported in most studies or when reported, the diagnostic criteria were unclear or of dubious quality. The outcome of this review suggests that peri-implant bone loss around minimally rough implant systems was statistically significant less in comparison to the moderately rough and rough implant systems. No statistically significant difference was observed between moderately rough and rough implant systems. The studies that compared implants with comparable design and different surface roughness, showed less average peri-implant bone loss around the less rough surfaces in the meta-analysis. However, due to the heterogeneity of the papers and the multifactorial cause for bone loss, the impact of surface roughness alone seems rather limited and of minimal clinical importance. Irrespective of surface topography or implant brand, the average weighted implant survival rate was 97.3% after 5 years or more of loading. If considering 3 mm bone loss after at least 5 years to represent the presence of "peri-implantitis," less than 5% of the implants were affected. The meta-analysis indicated that periodontal history and smoking habits yielded more bone loss.
Collapse
Affiliation(s)
- Ron Doornewaard
- Specialist in training, Master student Periodontology, Department Periodontology & Oral Implantology, Dental School, Faculty Medicine and Health Sciences, Ghent University Belgium
| | - Véronique Christiaens
- PhD student, Department Periodontology & Oral Implantology, Dental School, Faculty Medicine and Health Sciences, Ghent University Belgium
| | - Hugo De Bruyn
- full professor and chairman, Department Periodontology & Oral Implantology, Dental School, Faculty Medicine and Health Sciences, Ghent University Belgium, visiting professor, Department of Prosthodontics, Malmö University, Sweden
| | - Magnus Jacobsson
- adjunct professor, Department of Prosthodontics, Malmö University, Sweden
| | - Jan Cosyn
- professor, Department Periodontology & Oral Implantology, Dental School, Faculty Medicine and Health Sciences, Ghent University Belgium, professor, Faculty of Medicine and Health Sciences, Oral Health Research Group ORHE, Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Brussels, Belgium
| | - Stijn Vervaeke
- assistant professor, Department Periodontology & Oral Implantology, Dental School, Faculty Medicine and Health Sciences, Ghent University Belgium
| | - Wolfgang Jacquet
- professor, Faculty of Medicine and Pharmacy, Department of Educational Sciences EDWE-LOCI, Faculty of Psychology and Educational Sciences, Vrije Universiteit Brussel, Brussels, Belgium, professor, Faculty of Medicine and Health Sciences, Oral Health Research Group ORHE, Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Brussels, Belgium
| |
Collapse
|
10
|
Drago C. Frequency and Type of Prosthetic Complications Associated with Interim, Immediately Loaded Full-Arch Prostheses: A 2-Year Retrospective Chart Review. J Prosthodont 2015; 25:433-9. [PMID: 26372550 DOI: 10.1111/jopr.12343] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/20/2015] [Indexed: 12/01/2022] Open
Abstract
PURPOSE The purpose of this report was to retrospectively evaluate implant and immediate full-arch prosthesis survival rates over a 24-month period; patients were consecutively treated with immediate occlusal loading. Dental arch, gender, and implant orientation (vertical vs. tilted) were also noted. MATERIALS AND METHODS All Brånemark System implants (Nobel Active) and interim, all-acrylic resin prostheses placed in patients following an All-on-Four™ protocol, in a single private practice were assessed by retrospective patient chart review. The amount of space provided surgically for implant restorative components and prostheses was determined from measurements of the vertical heights of the interim prostheses in the right/left anterior and posterior segments. These measurements were made in the laboratory. Interim prosthetic repairs (type, frequency, length of time from insertion) were analyzed by type, arch, gender, and implant orientation. Implant survival and insertion torque values were also measured. Inclusion criteria consisted of all Brånemark System implants placed with the All-on-Four protocol from September 1, 2011, until August 31, 2013. Specific dietary instructions were given for the first 7 days immediately postoperatively and for the weeks prior to insertion of the definitive prostheses. RESULTS One hundred twenty-nine patients, comprising 191 arches (766 implants) from September 1, 2011, until August 31, 2013, were included in the study. One patient experienced implant failure yielding an overall implant survival rate (SR) of 99.5% (762 of 766). Four hundred twenty-six of 430 maxillary implants and 336 of 336 mandibular implants survived for SRs of 99.1% and 100%, respectively. Regarding implant orientation, 415 of 417 tilted implants (SR 99.5%) and 343 of 345 (CSR 95.6%) vertical implants were noted to be clinically stable. Interim, all-acrylic resin prostheses were in place for a mean of 199.2 days; mandibular prostheses were in place for an average of 195.4 days; maxillary prostheses were in place for an average of 202.0 days. Thirty four of the 191 interim prostheses (17.8%) warranted at least one repair during the treatment period. The average overall implant insertion torque value was 60.74 Ncm; mandibular torque values averaged 63.08 Ncm; maxillary torque values averaged 59.00 Ncm. CONCLUSIONS The results from this study suggest that dental arch, gender, and implant orientation for implants placed and immediately restored with interim, all-acrylic resin, full-arch prostheses per the All-on-Four protocol did not have significant statistical or clinical effects on prosthetic complications of the interim prostheses or implant survival. Only one of the 129 patients experienced implant failures, indicating that the All-on-Four treatment protocol used in this study is a viable alternative to other protocols for rehabilitating edentulous patients.
Collapse
Affiliation(s)
- Carl Drago
- Department of Dental Specialties, Gundersen Health System, LaCrosse, WI.,Department of General Dental Sciences, Marquette University School of Dentistry, Milwaukee, WI.,Eon Clinics, Waukesha, WI
| |
Collapse
|
11
|
Romanos GE, Aydin E, Locher K, Nentwig GH. Immediate vs. delayed loading in the posterior mandible: a split-mouth study with up to 15 years of follow-up. Clin Oral Implants Res 2014; 27:e74-9. [DOI: 10.1111/clr.12542] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/24/2014] [Indexed: 12/01/2022]
Affiliation(s)
- Georgios E. Romanos
- Department of Oral Surgery and Implant Dentistry; Dental School; Johann Wolfgang Goethe University; Frankfurt Germany
- School of Dental Medicine; Stony Brook University; Stony Brook NY USA
| | - Erhan Aydin
- Department of Oral Surgery and Implant Dentistry; Dental School; Johann Wolfgang Goethe University; Frankfurt Germany
| | - Kathrin Locher
- Department of Oral Surgery and Implant Dentistry; Dental School; Johann Wolfgang Goethe University; Frankfurt Germany
| | - Georg-Hubertus Nentwig
- Department of Oral Surgery and Implant Dentistry; Dental School; Johann Wolfgang Goethe University; Frankfurt Germany
| |
Collapse
|