1
|
Possebon APDR, Schuster AJ, Chagas-Júnior OL, Pinto LDR, Faot F. Immediate versus conventional loading of mandibular implant-retained overdentures: a 3-year follow-up of a randomized controlled trial. Clin Oral Investig 2023; 27:5935-5946. [PMID: 37612525 DOI: 10.1007/s00784-023-05205-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Accepted: 08/11/2023] [Indexed: 08/25/2023]
Abstract
OBJECTIVES There is a scarcity of randomized clinical trials (RCT) that report medium- and long-term results and a lack of consensus in the literature on the predictability of immediately loaded unsplinted narrow diameter implants supporting mandibular overdentures. This RCT compared the performance of conventional (CL) and immediate loading (IL) of mandibular overdentures retained by two narrow-diameter implants for 3 years. MATERIALS AND METHODS Patients from an RCT treated with CL or IL were invited to attend to 2- and 3-year follow-ups. Clinical, radiographic, functional, and oral health-related quality of life parameters were evaluated. Prosthetic maintenance events, biological complications, and success and survival rates were also recorded. The data were tested by multilevel mixed-effects linear regression analysis and chi-squared tests. RESULTS The 1-year survival rates of 90% in the CL group and 85% in the IL group were maintained as no implants were lost between 1 and 3 years. The marginal bone loss (MBL) in the IL group was significantly lower after year 3 (-0.04; p < 0.01). Significant changes were found only for the intra-group comparisons in the third year of function: (i) CL and IL presented similar progression of implant stability, MBL, and posterior bone area resorption; (ii) while CL started deteriorating of masticatory function, IL still exhibited functional evolution and (iii) oral comfort domain in the CL and pain domain in the IL were improved. CONCLUSION Although IL experienced the lowest MBL after 3 years, the outcomes showed that both loading protocols result in predictable medium-term rehabilitation when monitored annually. CLINICAL RELEVANCE It can be expected that in the third year of function, patients with immediate loading may present more complaints related to general performance even with acceptable masticatory function and self-reported improvements in oral comfort.
Collapse
Affiliation(s)
- Anna Paula da Rosa Possebon
- Department of Restorative Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil
| | - Alessandra Julie Schuster
- School of Dentistry, Federal University of Pelotas, Gonçalves Chaves Street 457, Pelotas, RS, 96015-560, Brazil
| | - Otacílio Luiz Chagas-Júnior
- Department of Oral and Maxillofacial Surgery and Maxillofacial Prosthodontics, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil
| | - Luciana de Rezende Pinto
- Department of Restorative Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil
| | - Fernanda Faot
- Department of Restorative Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil.
| |
Collapse
|
2
|
Watanabe M, Kanazawa M, Sato D, Uehara Y, Miyayasu A, Iwaki M, Komagamine Y, Naing ST, Katheng A, Kusumoto Y, Abe Y, Baba K, Minakuchi S. Oral function of implant-assisted removable partial dentures with magnetic attachments using short implants: A prospective study. Clin Oral Implants Res 2022; 33:1265-1272. [PMID: 36222311 DOI: 10.1111/clr.14008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 09/22/2022] [Accepted: 10/02/2022] [Indexed: 12/13/2022]
Abstract
OBJECTIVES This prospective study aimed to compare the oral functions of removable partial dentures (RPDs) with those of implant-assisted removable partial dentures (IARPDs) with short implants and magnetic attachments in patients with mandibular Kennedy class I and II. MATERIAL AND METHODS Thirty participants with mandibular Kennedy class I or II and at least three distal missing teeth were recruited. Oral functions, including mixing ability, comminuting ability, maximum bite force, and occlusal contact area, were assessed for RPDs (stage 0), IARPDs with healing caps (stage 1), and IARPDs with magnetic attachments (stage 2). The implants were loaded with occlusal force in stages 1 and 2. Finally, the data of the 27 participants who completed the evaluation at stage 2 were analyzed. The Wilcoxon signed-rank test with Bonferroni correction was used to assess the differences in the oral functions among the different stages. RESULTS The implant survival rate was 93.8%. There were significant differences in the comminuting ability and occlusal contact area between stages 0 and 2 (p < .001 and p = .036, respectively) and stages 1 and 2 (p = .003 and p = .015, respectively). Regarding the maximum bite force, there was a significant difference between stages 1 and 2 (p = .018). However, there was no significant difference in the mixing ability between the three stages. CONCLUSIONS Within the limitations of this study, it was concluded that IARPDs in the mandible with short implants and magnetic attachments may improve oral functions.
Collapse
Affiliation(s)
- Masataka Watanabe
- Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Manabu Kanazawa
- Digital Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Daisuke Sato
- Department of Implant Dentistry, School of Dentistry, Showa University, Tokyo, Japan
| | - Yoko Uehara
- Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Anna Miyayasu
- Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Maiko Iwaki
- Digital Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Yuriko Komagamine
- Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Sai Tun Naing
- Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Awutsadaporn Katheng
- Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Yuriko Kusumoto
- Department of Prosthodontics, School of Dentistry, Showa University, Tokyo, Japan
| | - Yuka Abe
- Department of Prosthodontics, School of Dentistry, Showa University, Tokyo, Japan
| | - Kazuyoshi Baba
- Department of Prosthodontics, School of Dentistry, Showa University, Tokyo, Japan
| | - Shunsuke Minakuchi
- Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
3
|
Nagay BE, Dini C, Borges GA, Mesquita MF, Cavalcanti YW, Magno MB, Maia LC, Barão VAR. Clinical efficacy of anodized dental implants for implant-supported prostheses after different loading protocols: A systematic review and meta-analysis. Clin Oral Implants Res 2021; 32:1021-1040. [PMID: 34352130 DOI: 10.1111/clr.13813] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Revised: 06/10/2021] [Accepted: 07/06/2021] [Indexed: 01/05/2023]
Abstract
OBJECTIVES To summarize the clinical performance of anodized implants connected to different prostheses design after immediate/early (IL) or conventional loading (CL) protocols. MATERIALS AND METHODS Seven databases were surveyed for randomized (RCTs) and non-randomized controlled clinical trials (CCTs). Studies comparing IL vs. CL protocol of anodized implants supporting single crown, fixed partial denture (FPD), full-arch fixed dental prosthesis (FDP), or overdenture were included. Risk-of-bias was evaluated using Cochrane Collaboration tools. Meta-analyses for different follow-up were analyzed, followed by heterogeneity source assessment and GRADE approach. The outcomes included implant survival rate, marginal bone loss (MBL), implant stability quotient (ISQ), probing depth (PD), plaque index (PI), and peri-implantitis prevalence. RESULTS From 24 eligible studies, 22 were included for quantitative evaluation. Most RCTs (58%, n = 11) and all the 5 CCTs had high and serious risk-of-bias, respectively. Overall, pooling all prosthesis design, no difference between IL vs. CL protocols was observed for all outcomes (p > .05). However, according to prosthesis type subgroups, CL reduced MBL for full-arch FDP (p < .05). In a point-in-time assessment, with overdenture, although IL presented higher PI (12 months), it showed lower MBL (≥24 months), higher ISQ (3 months), and lower PD (6 and 12 months) (p < .05). Conversely, PD was higher for IL in single crown (3 and 6 months) (p < .05). Regarding MBL, IL demonstrated higher mean difference for full-arch FDP (36 months) and FPD (12 and 36 months) (p < .05). CONCLUSION Within the limitations of this study, overall, there is no significant difference in the outcomes between IL and CL loading protocols.
Collapse
Affiliation(s)
- Bruna Egumi Nagay
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Brazil
| | - Caroline Dini
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Brazil
| | - Guilherme Almeida Borges
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Brazil
| | - Marcelo Ferraz Mesquita
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Brazil
| | - Yuri Wanderley Cavalcanti
- Department of Clinic and Social Dentistry, Federal University of Paraiba (UFPB), João Pessoa, Brazil
| | - Marcela Baraúna Magno
- Department of Pediatric Dentistry and Orthodontics, School of Dentistry, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Brazil
| | - Lucianne Cople Maia
- Department of Pediatric Dentistry and Orthodontics, School of Dentistry, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Brazil
| | - Valentim Adelino Ricardo Barão
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Brazil
| |
Collapse
|
4
|
Functional and Patient-Centered Treatment Outcomes with Mandibular Overdentures Retained by Two Immediate or Conventionally Loaded Implants: A Randomized Clinical Trial. J Clin Med 2021; 10:jcm10163477. [PMID: 34441773 PMCID: PMC8396916 DOI: 10.3390/jcm10163477] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 07/19/2021] [Accepted: 07/22/2021] [Indexed: 10/25/2022] Open
Abstract
This study aims to assess the treatment outcomes (functional and subjective) of mandibular overdentures retained on two implants with or without an immediate loading protocol. In this randomized clinical trial, twenty fully edentulous patients were treated with a mandibular two-implant-retained overdenture and a complete new maxillary denture. In half of the sample, the implants were loaded immediately by means of VulkanLoc® abutments after emplacement of the implant, but in the counterparts, these VulkanLoc® abutments were connected to implants two months after the surgery (conventional protocol), and until that time the dentures were retained by healing abutments. Treatment outcomes were assessed at two, six, and twelve months after surgery. Functional outcomes were calculated according to masticatory performance, estimated by the mixed fraction of a two-coloured chewing gum after five, ten, and fifteen chewing strokes, by the occlusal force recorded by pressure-sensitive sheets, and by the bioelectrical muscular activity. The subjective outcomes of the treatment were assessed using both the oral satisfaction scale (visual analogue scale) and the Spanish version of the Oral Health Impact Profile (OHIP-20). The findings of the present study show that new complete dentures resulted in significant improvements in chewing ability, patient satisfaction, and oral health-related quality of life and that subsequent implant-retained overdentures produced further and faster significant improvements. The loading protocol may influence those positive self-reported outcomes rather than the objective functional evaluations.
Collapse
|
5
|
Katheng A, Kanazawa M, Komagamine Y, Miyayasu A, Uehara Y, Sato D, Minakuchi S. Masticatory performances and maximum occlusal forces of immediate and conventional loaded two-implant supported overdentures retained by magnetic attachments: preliminary study of randomized controlled clinical trial. Int J Implant Dent 2021; 7:57. [PMID: 34184165 PMCID: PMC8239120 DOI: 10.1186/s40729-021-00342-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Accepted: 04/11/2021] [Indexed: 12/05/2022] Open
Abstract
Background The appropriate loading protocol to improve masticatory performance (MP) is still unclear in elderly patients and two-implant overdentures (2-IODs) wearers. This study aimed to compare the long-term MP and maximum occlusal force of immediate loading (IL) and conventional loading (CL) of 2-IODs retained by magnetic attachments. Nineteen edentulous patients were randomly assigned to either an IL (n=10) or CL group (n = 9). In the IL group, the implant was loaded on the same day as insertion, whereas it was loaded 3 months after insertion in the CL group. Magnetic attachments were used to retain all overdentures to the implants. MP, measured by a piece of color-changeable chewing gum and a gummy jelly test, and maximum occlusal force, measured using an occlusal force measuring device, were assessed in both groups at baseline and at 3-, 4-, and 5-year follow-ups. Results No significant differences were observed in the MP and the maximum occlusal force between the IL and CL groups at any time point. However, a significantly higher MP was observed at the 3-year time point in the IL group (P = 0.036). The maximum occlusal force revealed a significant correlation with MP, both with the color-changeable chewing gum and gummy jelly at 5 years. Conclusion After long-term observation, no significant differences in MP and maximum occlusal force were observed between the IL and CL groups. However, compared to pre-implant insertion of the complete denture, the MP in the IL group significantly improved at 3 years. Furthermore, the maximum occlusal force was significantly correlated with MP at 5 years. Trial registration UMIN, UMIN000009889. Registered on 28 January 2013.
Collapse
Affiliation(s)
- Awutsadaporn Katheng
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan.,Department of Restorative Dentistry, Faculty of Dentistry, Naresuan University, Phitsanulok, Thailand
| | - Manabu Kanazawa
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan.
| | - Yuriko Komagamine
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Anna Miyayasu
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Yoko Uehara
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Daisuke Sato
- Department of Implant Dentistry, School of Dentistry, Showa University, Tokyo, Japan
| | - Shunsuke Minakuchi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
6
|
Borges GA, Costa RC, Nagay BE, Magno MB, Maia LC, Barão VAR, Mesquita MF. Long-term outcomes of different loading protocols for implant-supported mandibular overdentures: A systematic review and meta-analysis. J Prosthet Dent 2021; 125:732-745. [DOI: 10.1016/j.prosdent.2020.04.017] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2019] [Revised: 04/14/2020] [Accepted: 04/14/2020] [Indexed: 12/17/2022]
|
7
|
Ye M, Liu W, Cheng S, Yan L. Immediate vs conventional loading of mandibular overdentures: A comprehensive systematic review and meta-analysis of randomized controlled trials. J ORAL IMPLANTOL 2020; 48:64-73. [PMID: 33206979 DOI: 10.1563/aaid-joi-d-20-00265] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Clinicians treating overdenture patients need to know if immediate loading and conventional loading results in similar outcomes. This study aimed to perform a systematic literature search of studies comparing immediate and conventional loading of mandibular overdentures irrespective of the number of implants and conduct a meta-analysis of implant failure and marginal bone loss (MBL). A literature search of PubMed, ScienceDirect, Ovoid, Springer, and Google Scholar databases was performed for randomized controlled trials (RCTs) comparing immediate vs conventional loading of mandibular overdentures. The primary outcome was implant failure and the secondary outcome was marginal bine loss (MBL). A descriptive analysis was performed for other outcomes. Thirteen trials were included. Only one trial compared the immediate and delayed loading of single implant-supported overdenture. Seven trials used two implants, one trial used three implants while four trials used four implants. Meta-analysis indicated no statistically significant difference in implant failure and MBL between immediate and conventional loading of two-implant and four-implant supported overdentures. Descriptive analysis indicated no difference in peri-implant tissue indices, implant stability, and quality of life outcomes between the two loading protocols.There may be no difference in implant failure and MBL with immediate loading or conventional loading of two and four-implant supported mandibular overdentures. Literature review indicates that there may be no difference in peri-implant tissue indices, implant stability, and QoL outcomes between the two loading protocols. The overall quality of evidence is moderate. Further, adequately powered RCTs are required to strengthen the evidence.
Collapse
Affiliation(s)
- Mingfu Ye
- Stomatological Hospital of Xiamen Medical College, Xiamen Key Laboratory of Stomatological Disease Diagnosis and Treatment Department of Oral Implantology No. 1309, Lvling Road CHINA Xiamen Fujian 361008 Department of Oral Implantology, Stomatological Hospital of Xiamen Medical College, Xiamen Key Laboratory of Stomatological Disease Diagnosis and Treatment
| | - Wenjun Liu
- Department of Oral Implantology, Stomatological Hospital of Xiamen Medical College, Xiamen Key Laboratory of Stomatological Disease Diagnosis and Treatment
| | - Shaolong Cheng
- Department of Oral Implantology, Stomatological Hospital of Xiamen Medical College, Xiamen Key Laboratory of Stomatological Disease Diagnosis and Treatment
| | - Lihui Yan
- Department of Oral Implantology, Stomatological Hospital of Xiamen Medical College, Xiamen Key Laboratory of Stomatological Disease Diagnosis and Treatment
| |
Collapse
|
8
|
Immediate or delayed loading protocols for two-implant mandibular overdentures: A systematic review and meta-analysis of randomized controlled trials. J Prosthet Dent 2020; 126:742-748. [PMID: 33139056 DOI: 10.1016/j.prosdent.2020.09.011] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 09/29/2020] [Accepted: 09/29/2020] [Indexed: 12/12/2022]
Abstract
STATEMENT OF PROBLEM The immediate loading protocol for 2-implant mandibular overdentures has been widely reported. Nevertheless, the clinical effects reported in different articles are quite different. PURPOSE The purpose of this systematic review and meta-analysis of randomized controlled trials (RCTs) was to compare the clinical effects of immediate and delayed loading of 2-implant mandibular overdentures. MATERIAL AND METHODS The review followed the guidelines of Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA). PubMed, Cochrane Library, Web of Science, Embase, Scopus, ScienceDirect, CBM, CNKI, and Wan Fang databases were searched electronically for RCTs published before March 25, 2020. Two authors independently conducted literature screening, quality assessment, and data extraction. The outcomes of interest were implant failure rate, marginal bone loss (MBL), implant stability quotient (ISQ), periotest value (PTV), and patient satisfaction. RESULTS A total of 2498 unduplicated records were identified. After full-text analysis, 7 eligible RCTs were included. All studies were followed for at least 12 months, and the meta-analysis was based on this. The meta-analysis showed that the implant failure rate in the immediate group was higher than that in the delayed group, but there was no statistically significant difference (I2=0%; n=7; risk difference [RD]=0.03; 95% confidence interval [CI]=-0.01 to 0.08). The difference of MBL between immediate and delayed loading was not significant (I2=88%; n=6; mean difference [MD]=-0.04; 95% CI=-0.16 to 0.24). Because of the limited articles reporting on ISQ, PTV, and patient satisfaction, no quantitative analysis was conducted for these outcomes. CONCLUSIONS Although the implant failure rate was more likely to favor the delayed group, available evidence indicates no statistical difference in implant failure and marginal bone loss between immediate and delayed loading protocols.
Collapse
|
9
|
Schuster AJ, Marcello-Machado RM, Bielemann AM, Possebon APDR, Chagas Júnior OL, Faot F. Immediate vs conventional loading of Facility-Equator system in mandibular overdenture wearers: 1-year RCT with clinical, biological, and functional evaluation. Clin Implant Dent Relat Res 2020; 22:270-280. [PMID: 32363765 DOI: 10.1111/cid.12902] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Revised: 01/20/2020] [Accepted: 03/10/2020] [Indexed: 01/09/2023]
Abstract
BACKGROUND The use of immediate loading (IML) is still poorly explored in elderly patients and implant-retained mandibular overdenture (IMO) wearers. For this reason, more comparisons to conventional loading (CL) are required. PURPOSE To evaluate the clinical, biological, functional, and oral health-related quality of life (OHRQOL) influence of CL and IML loading on elders wearing IMO retained by the Facility-Equator system up to 1 year after implant installation. MATERIAL AND METHODS Twenty edentulous patients received two narrow diameter implants in the mandible; the loading type (CL or IML) was randomized. The clinical parameters were monitored along with prosthetic events, marginal bone loss (MBL) and bone level change (BLC), implant stability quotients (ISQ), masticatory performance outcomes, and Interleukin 1 beta (IL-1β) and tumor necrosis factor alpha (TNF-α) levels in the peri-implant crevicular fluid during the first year of loading. The OHRQoL was assessed via the Oral Health Impact Profile-EDENT questionnaire. Data were analyzed by the Mann-Whitney, χ2 , Wilcoxon paired, and McNemar tests. RESULTS After 1 year, MBL, BLC and ISQ were statistically identical (P > .05) in the CL and IML groups. The probing depth at 12 months in the CL group (2.19 mm) was higher than in the IML group (1.29 mm; P ≤ .0001). TNF-α was 33.6% higher in the CL group at 6 months (P = .043), while IL-1β was significantly higher in the IML group up to 6 months. The survival rate was 90% in the CL group and 85% in the IML group; 33 prosthetic events occurred in CL group and 23 in IML group. CONCLUSIONS After 12 months, both loading protocols are viable and result in similar clinical, biological, functional, and OHRQOL outcomes. However, IML generates better adaptation of the peri-implant tissues, faster improvement in OHRQoL and fewer prosthetic intercurrences than CL.
Collapse
Affiliation(s)
- Alessandra J Schuster
- Graduate Program in Dentistry, School of Dentistry, Federal University of Pelotas, Rio Grande do Sul, Brazil
| | - Raissa M Marcello-Machado
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas, Piracicaba, São Paulo, Brazil
| | - Amália M Bielemann
- Graduate Program in Dentistry, School of Dentistry, Federal University of Pelotas, Rio Grande do Sul, Brazil
| | - Anna Paula da Rosa Possebon
- Graduate Program in Dentistry, School of Dentistry, Federal University of Pelotas, Rio Grande do Sul, Brazil
| | - Otacílio L Chagas Júnior
- Department of Oral and Maxillofacial Surgery and Maxillofacial Prosthodontics, School of Dentistry, Federal University of Pelotas, Pelotas, Rio Grande do Sul, Brazil
| | - Fernanda Faot
- Department of Restorative Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, Rio Grande do Sul, Brazil
| |
Collapse
|