1
|
Canullo L, Menini M, Pesce P, Iacono R, Sculean A, Del Fabbro M. Nano-superhydrophilic and bioactive surface in poor bone environment. Part 1: transition from primary to secondary stability. A controlled clinical trial : Bioactive implant surfaces in poor density bone. Clin Oral Investig 2024; 28:372. [PMID: 38872049 PMCID: PMC11176097 DOI: 10.1007/s00784-024-05747-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Accepted: 05/27/2024] [Indexed: 06/15/2024]
Abstract
OBJECTIVES Bioactive surfaces were designed to increase the interaction between the surface and the cells. This may speed up the biological stability and loading protocols. MATERIALS AND METHODS 36 patients with D3-D4 bone density were recruited and allocated into two groups. 30 bioactive (test group) and 30 traditional (control group) surfaced implants were placed. Insertion torque value (Ncm), insertion torque curve integral (cumulative torque, Ncm), torque density (Ncm/sec), implant stability quotient (ISQ) measured at three timepoints (baseline (T0), 30 (T30) and 45 (T45) days after surgery), and marginal bone loss (MBL) at 6 months of loading were assessed. RESULTS The mean ISQ and standard deviation at T0, T30, T45 were respectively 74.57 ± 7.85, 74.78 ± 7.31, 74.97 ± 6.34 in test group, and 77.12 ± 5.83, 73.33 ± 6.13, 73.44 ± 7.89 in control group, respectively. Data analysis showed significant differences between groups in ΔISQ at T0-T30 (p = 0.005) and T30-T45 (p = 0.012). Control group showed a significant decrease in ISQ at T30 (p = 0.01) and T45 (p = 0.03) compared to baseline, while no significant change was observed in test group. Due to the stability of the ISQ value ≥ 70, 26 test group and 23 control group implants were functionally loaded after 45 days. Conversely, due to the ISQ < 70 at T45, four test group implants and one control group implant were loaded after 90 days, and 6 control group implants were loaded after 180 days. Neither insertion torque nor ISQ at baseline were correlated with bone density (in Hounsfield units). There was no significant correlation between cumulative torque and ISQ at baseline. There was a significant positive slope in the correlation between torque density and ISQ at baseline, more accentuated in D3 than D4. This correlation remained significant for the test group in D3 bone at day 30 and 45 (p < 0.01 in both time frames), but not in D4 bone, and it was not significant in CG. CONCLUSIONS The bioactive surface showed better behavior in terms of implant stability in D3-D4 bone quality in the early stages of bone healing. Clinical relevance This study demonstrated that the transition from primary to secondary stability is improved using bioactive surface, especially in cases of poor bone environment (D3/D4 bone).
Collapse
Affiliation(s)
- Luigi Canullo
- Department of Surgical Sciences (DISC), University of Genoa, Largo R. Benzi 10, Genoa, 16132, Italy.
- Department of Periodontology, University of Bern, Bern, Switzerland.
| | - Maria Menini
- Department of Surgical Sciences (DISC), University of Genoa, Largo R. Benzi 10, Genoa, 16132, Italy
| | - Paolo Pesce
- Department of Surgical Sciences (DISC), University of Genoa, Largo R. Benzi 10, Genoa, 16132, Italy
| | - Roberta Iacono
- Department of Oral and Maxillo-facial Sciences, "Sapienza" University of Rome, Via Caserta 6, Rome, 00161, Italy
| | - Anton Sculean
- Department of Periodontology, University of Bern, Bern, Switzerland
| | - Massimo Del Fabbro
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| |
Collapse
|
2
|
Liu X, Lv H, Chen M, Chen S, Jia K, Quni S, Zhang L, Zhou Y. Case report and literature review: autonomous robotic system assisted palatal implantation at an anterior teeth site compromised by periapical cyst. Front Med (Lausanne) 2024; 11:1335043. [PMID: 38288274 PMCID: PMC10822917 DOI: 10.3389/fmed.2024.1335043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Accepted: 01/02/2024] [Indexed: 01/31/2024] Open
Abstract
Background Immediate implant placement (IIP), which preserves gingival height and papilla shape while simultaneously accelerating the implant treatment period, has become a popular method due to its commendable clinical outcomes. Nonetheless, deploying immediate implants demands specific preconditions concerning the remaining alveolar bone. This poses a challenge to the accuracy of implant surgery. Case presentation In this report, we present the case of a 60-year-old woman with a left upper anterior tooth crown dislodged for over a month. Cone beam computed tomography (CBCT) revealed the absence of a labial bone wall on tooth 22, a remaining 1 mm bone wall on the labial side of the root apex, and a 17.2 mm*8.9 mm*4.7 mm shadow in the periapical region of the root apices of teeth 21 and 22, with the narrowest width on the sagittal plane being approximately 5 mm. After the surgeon removed the cyst, they completed the subsequent implantation surgery using an autonomous robot in a challenging aesthetic area. This method circumvented the potential exposure of the screw thread on the labial implant surface, assured initial implant stability. Conclusion Five months after the operation, the dental crown was restored. The implant remained stable, with yielding notable clinical results. To the best of our knowledge, this clinical case is the first to report the feasibility and precision of immediate implantation in anterior teeth site with periapical cyst removal, performed by an autonomous robotic surgical system. Autonomous robots exhibit exceptional accuracy by accurately controlling axial and angular errors. It can improve the accuracy of implant surgery, which may become a key technology for changing implant surgery. However, further clinical trials are still needed to provide a basis for the rapid development of robotic surgery field.
Collapse
Affiliation(s)
- Xiuyu Liu
- Hospital of Stomatogy, Jilin University, Changchun, China
| | - Huixin Lv
- Hospital of Stomatogy, Jilin University, Changchun, China
| | - Meiqing Chen
- Department of Stomatology, China-Japan Union Hospital of Jilin University, Changchun, China
| | - Siyu Chen
- Hospital of Stomatogy, Jilin University, Changchun, China
| | - Kewen Jia
- Hospital of Stomatogy, Jilin University, Changchun, China
| | - Sezhen Quni
- Hospital of Stomatogy, Jilin University, Changchun, China
| | - Lu Zhang
- Hospital of Stomatogy, Jilin University, Changchun, China
| | - Yanmin Zhou
- Hospital of Stomatogy, Jilin University, Changchun, China
| |
Collapse
|
3
|
Manfredini M, Poli PP, Maiorana C, Salina FE, Tandurella M, Beretta M. Computer Aided Full Arch Restoration by Means of One-Piece Implants and Stackable Guide: A Technical Note. Dent J (Basel) 2023; 11:256. [PMID: 37999020 PMCID: PMC10670089 DOI: 10.3390/dj11110256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 10/22/2023] [Accepted: 10/30/2023] [Indexed: 11/25/2023] Open
Abstract
This technical note aims to present a recently developed computer-guided protocol characterized by titanium-reinforced stackable surgical guides during post-extractive implant placement and subsequent immediate loading. A full maxillary edentulism was rehabilitated with one-piece implants, starting from a pre-existing removable denture. 3D digital scans of the removable denture and upper and lower arches were performed. On this basis, a prototype with ideal esthetic and functional outcomes was realized and replicated into a custom-made radiological stent with markers. The superimposition of STL and DICOM files allowed virtual planning of one-piece implants in the ideal prosthetically driven position. The stackable guides, composed of a fixed base template and additional removable components, were then realized. The fixed template, initially secured with anchor pins to the bone, was no longer removed. The removable components, which were screwed to the base template, were used to perform implant surgery and immediate prosthetic loading. No surgical complications occurred, the implants achieved a minimum insertion torque of 35 Ncm, and immediate prosthetic loading was performed. The base template allowed for the maintenance of a fixed reference during the entire workflow, improving the transition between the digital project, the surgical procedure, and the prosthetic rehabilitation.
Collapse
Affiliation(s)
- Mattia Manfredini
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy; (M.M.); (C.M.); (F.E.S.); (M.T.); (M.B.)
- Implant Center for Edentulism and Jawbone Atrophies, Maxillofacial Surgery and Dental Unit, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy
| | - Pier Paolo Poli
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy; (M.M.); (C.M.); (F.E.S.); (M.T.); (M.B.)
- Implant Center for Edentulism and Jawbone Atrophies, Maxillofacial Surgery and Dental Unit, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy
| | - Carlo Maiorana
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy; (M.M.); (C.M.); (F.E.S.); (M.T.); (M.B.)
- Implant Center for Edentulism and Jawbone Atrophies, Maxillofacial Surgery and Dental Unit, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy
| | - Federica Eugenia Salina
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy; (M.M.); (C.M.); (F.E.S.); (M.T.); (M.B.)
- Implant Center for Edentulism and Jawbone Atrophies, Maxillofacial Surgery and Dental Unit, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy
| | - Marco Tandurella
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy; (M.M.); (C.M.); (F.E.S.); (M.T.); (M.B.)
- Implant Center for Edentulism and Jawbone Atrophies, Maxillofacial Surgery and Dental Unit, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy
| | - Mario Beretta
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy; (M.M.); (C.M.); (F.E.S.); (M.T.); (M.B.)
- Implant Center for Edentulism and Jawbone Atrophies, Maxillofacial Surgery and Dental Unit, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy
| |
Collapse
|
4
|
Antonelli A, Barone S, Attanasio F, Salviati M, Cerra MG, Calabria E, Bennardo F, Giudice A. Effect of Implant Macro-Design and Magnetodynamic Surgical Preparation on Primary Implant Stability: An In Vitro Investigation. Dent J (Basel) 2023; 11:227. [PMID: 37886912 PMCID: PMC10605303 DOI: 10.3390/dj11100227] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Revised: 09/17/2023] [Accepted: 09/20/2023] [Indexed: 10/28/2023] Open
Abstract
BACKGROUND Macro-geometry and surgical implant site preparation are two of the main factors influencing implant stability and potentially determining loading protocol. The purpose of this study was to assess the initial stability of various implant macro-designs using both magnetodynamic and traditional osteotomy techniques in low-density bone. The parameters examined included peak insertion torque (PIT), implant stability quotient (ISQ), and peak removal torque (PRT). METHODS Four groups of 34 implants each were identified in accordance with the surgery and implant shape: T5 group (Five implant and osteotomy using drills); M5 group (Five implant and magnetodynamic osteotomy using Magnetic Mallet); TT group (TiSmart implant and osteotomy with drills); and MT group (TiSmart implant and magnetodynamic osteotomy). Every implant was placed into a low-density bone animal model and scanned using CBCT. The PIT and PRT were digitally measured in Newton-centimeters (Ncm) using a torque gauge device. The ISQ was analyzed by conducting resonance frequency analysis. RESULTS The PIT values were 25.04 ± 4.4 Ncm for T5, 30.62 ± 3.81 Ncm for M5, 30 ± 3.74 Ncm for TT, and 32.05 ± 3.55 Ncm for MT. The average ISQ values were 68.11 ± 3.86 for T5, 71.41 ± 3.69 for M5, 70.88 ± 3.08 for TT, and 73 ± 3.5 for MT. The PRT values were 16.47 ± 4.56 Ncm for T5, 26.02 ± 4.03 Ncm for M5, 23.91 ± 3.28 Ncm for TT, and 26.93 ± 3.96 Ncm for MT. Based on our data analysis using a t-test with α = 0.05, significant differences in PIT were observed between TT and T5 (p < 0.0001), M5 and T5 (p < 0.0001), and MT and TT (p = 0.02). Significant differences in the ISQ were found between TT and T5 (p = 0.001), M5 and T5 (p < 0.001), and MT and TT (p = 0.01). The PRT also exhibited significant differences between TT and T5, M5 and T5, and MT and TT (p < 0.0001). CONCLUSION Our data showed favorable primary implant stability (PS) values for both implant macro-geometries. Furthermore, the magnetodynamic preparation technique appears to be more effective in achieving higher PS values in low-density bone.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Francesco Bennardo
- School of Dentistry, Department of Health Sciences, Magna Graecia University of Catanzaro, 88100 Catanzaro, Italy; (A.A.); (S.B.); (F.A.); (M.S.); (M.G.C.); (E.C.); (A.G.)
| | | |
Collapse
|
5
|
Khorshid HE, Issa NO, Ekram AM. Effect of implant diameter and cantilever length on the marginal bone height changes and stability of implants supporting screw retained prostheses: A randomized double blinded control trial. J Adv Prosthodont 2023; 15:101-113. [PMID: 37441715 PMCID: PMC10333100 DOI: 10.4047/jap.2023.15.3.101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Revised: 04/11/2023] [Accepted: 04/16/2023] [Indexed: 07/15/2023] Open
Abstract
PURPOSE This randomized controlled trial aimed to evaluate the effect of implants' two different diameters and cantilever lengths on the marginal bone loss and stability of mplants supporting maxillary prostheses. MATERIALS AND METHODS Ninety-six implants were placed in sixteen completely edentulous maxillary ridges. Patients were randomly divided into two groups: Group A, implants were placed with a cantilever to anterior-posterior AP spread length (CL:AP) at a ratio of 1:3; Group B, implants were placed with a CL:AP at a ratio of 1:2. Patients were further divided into four sub-groups: Groups A1, A2, B1, and B2. Groups A1 and B1 received small diameter implants while Groups A2 and B2 received standard diameter implants. Bone height and stability measurements around each implant were performed at 0, 4, 8 and 24 months after definitive prostheses delivery. RESULTS Statistical analysis of the mean implant stability and height values revealed an insignificant difference between Group A1 and Group A2 at all the different time intervals while significantly higher values in Group B1 in comparison with Group B2. Results also showed significantly higher values in Group A1 in comparison with Group B1 and an insignificant difference between Group A2 and Group B2 at all the different time intervals. CONCLUSION It can be concluded that the use of small diameter implants placed with a CL:AP at a ratio of 1:3 provided predictable results and that the 1:2 CL:AP significantly induced more critical bone loss in the small diameter implants group, which can significantly reduce long term success and survival of implants.
Collapse
Affiliation(s)
| | - Noha Ossama Issa
- Oral and Maxillofacial Radiology, Faculty of Dentistry, Cairo University, Giza, Egypt
| | - Amr Mohamed Ekram
- Oral and Maxillofacial Surgery Consultant, Private practice, Cairo, Egypt
| |
Collapse
|