1
|
Wong I, Zhang Z, Dang X, Yu X, Lin X, Li Y, Deng F, Xu R. Single missing molar with wide mesiodistal length restored using a single or double implant-supported crown: A self-controlled case report and 3D finite element analysis. J Prosthodont Res 2024:JPR_D_23_00278. [PMID: 38644231 DOI: 10.2186/jpr.jpr_d_23_00278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/23/2024]
Abstract
PURPOSE Based on a self-controlled case, this study evaluated the finite element analysis (FEA) results of a single missing molar with wide mesiodistal length (MDL) restored by a single or double implant-supported crown. METHODS A case of a missing bilateral mandibular first molar with wide MDL was restored using a single or double implant-supported crown. The implant survival and peri-implant bone were compared. FEA was conducted in coordination with the case using eight models with different MDLs (12, 13, 14, and 15 mm). Von Mises stress was calculated in the FEA to evaluate the biomechanical responses of the implants under increasing vertical and lateral loading, including the stress values of the implant, abutment, screw, crown, and cortical bone. RESULTS The restorations on the left and right sides supported by double implants have been used for 6 and 12 years, respectively, and so far have shown excellent osseointegration radiographically.The von Mises stress calculated in the FEA showed that when the MDL was >14 mm, both the bone and prosthetic components bore more stress in the single implant-supported strategy. The strength was 188.62-201.37 MPa and 201.85-215.9 MPa when the MDL was 14 mm and 15 mm, respectively, which significantly exceeded the allowable yield stress (180 MPa). CONCLUSIONS Compared with the single implant-supported crown, the double implant-supported crown reduced peri-implant bone stress and produced a more appropriate stress transfer model at the implant-bone interface when the MDL of the single missing molar was ≥14 mm.
Collapse
Affiliation(s)
- Iohong Wong
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Zhengchuan Zhang
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Xiaobing Dang
- Guangdong Janus Biotechnology Co., Ltd., Guangzhou, China
- Guangdong CAS Angels Biotechnology Co., Ltd., Foshan, China
| | - Xiaoran Yu
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Xiaoxuan Lin
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Yiming Li
- Department of Stomatology, the Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China
| | - Feilong Deng
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Ruogu Xu
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| |
Collapse
|
2
|
Goldstein G, Goodacre C, Brown MS, Tarnow DP. Proposal regarding potential causes related to certain complications with dental implants and adjacent natural teeth: Physics applied to prosthodontics. J Prosthodont 2024. [PMID: 38512996 DOI: 10.1111/jopr.13843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Accepted: 03/03/2024] [Indexed: 03/23/2024] Open
Abstract
PURPOSE Complications can and do occur with implants and their restorations with causes having been proposed for some single implant complications but not for others. METHODS A review of pertinent literature was conducted. A PubMed search of vibration, movement, and dentistry had 175 citations, while stress waves, movement, and dentistry had zero citations as did stress waves, movement. This paper discusses the physics of vibration, elastic and inelastic collision, and stress waves as potentially causative factors related to clinical complications. RESULTS Multiple potential causes for interproximal contact loss have been presented, but it has not been fully understood. Likewise, theories have been suggested regarding the intrusion of natural teeth when they are connected to an implant as part of a fixed partial denture as well as intrusion when a tooth is located between adjacent implants, but the process of intrusion, and resultant extrusion, is not fully understood. A third complication with single implants and their crowns is abutment screw loosening with several of the clinical characteristics having been discussed but without determining the underlying process(es). CONCLUSIONS Interproximal contact loss, natural tooth intrusion, and abutment screw loosening are common complications that occur with implant retained restorations. Occlusion is a significant confounding variable. The hypothesis is that vibration, or possibly stress waves, generated from occlusal impact forces on implant crowns and transmitted to adjacent teeth, are the causative factors in these events. Since occlusion appears to play a role in these complications, it is recommended that occlusal contacts provide centralized stability on implant crowns and not be located on any inclined surfaces that transmit lateral forces that could be transmitted to an adjacent tooth and cause interproximal contact loss or intrusion. The intensity, form, and location of proximal contacts between a natural tooth located between adjacent single implant crowns seem to play a role in the intrusion of the natural tooth. Currently, there is a lack of information about the underlying mechanisms related to these occurrences and research is needed to define any confounding variables.
Collapse
Affiliation(s)
- Gary Goldstein
- Department of Prosthodontics, New York University College of Dentistry, New York, New York, USA
| | - Charles Goodacre
- Advanced Education Program in Implant Dentistry, Loma Linda University School of Dentistry, Loma Linda, California, USA
| | | | - Dennis P Tarnow
- Columbia University College of Dental Medicine, New York, New York, USA
| |
Collapse
|
3
|
Goyeneche VP, Cortellari GC, Rodriguez F, De Aza PN, Maria da Costa E, Scarano A, Júnior NDB, Gehrke SA. Does the index in Morse taper connection affect the abutment stability? An in vitro experimental study. PLoS One 2024; 19:e0298462. [PMID: 38457413 PMCID: PMC10923422 DOI: 10.1371/journal.pone.0298462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 01/24/2024] [Indexed: 03/10/2024] Open
Abstract
The present study compared three different implant and abutment sets of type Morse taper (MT) connection, with- and without-index, were analyzed regarding their mechanical behavior without and with cyclic load application simulating the masticatory function. Ninety implant and abutment (IA) sets were used in the present study, divided into three groups (n = 30 samples per group): Group A, Ideale solid straight abutment (one piece) without index; Group B, Ideale abutment with an angle of 30-degree (two pieces) without index; Group C, Ideale abutment with an angle of 30-degree (two pieces) with index. The abutment stability quotient (ASQ) values, detorque value and rotation angle were measured before and after the cycling load. Twenty IA sets of each group were submitted to mechanical load at 360,000 cycles. The ASQ without load were 64.7 ± 2.49 for the group A, 60.2 ± 2.64 for the group B, 54.4 ± 3.27 for the group C; With load were 66.1 ± 5.20 for the group A, 58.5 ± 6.14 for the group B, 58.9 ± 2.99 for the group C. Detorque values were lower in groups B and C compared to group A (p < 0.05). In conclusion, the presence of the index did not influence the stability values. However, solid straight abutments (group A) showed higher values of stability compared to groups of angled abutments (groups B and C).
Collapse
Affiliation(s)
| | | | | | - Piedad N. De Aza
- Departament of Bioingenieria, Universidad Miguel Hernández de Elche, Alicante, Spain
| | - Eleani Maria da Costa
- Department of Materials Engineering, Pontificial Catholic University of Rio Grande do Sul, Porto Alegre, Brazil
| | - Antonio Scarano
- Departament of Implantology, Bioface/PgO/UCAM, Montevideo, Uruguay
- Department of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, Chieti CH, Italy
| | | | - Sergio Alexandre Gehrke
- Departament of Implantology, Bioface/PgO/UCAM, Montevideo, Uruguay
- Departament of Bioingenieria, Universidad Miguel Hernández de Elche, Alicante, Spain
- Department of Materials Engineering, Pontificial Catholic University of Rio Grande do Sul, Porto Alegre, Brazil
- Department of Biotechnology, Universidad Católica de Murcia (UCAM), Murcia, Spain
| |
Collapse
|
4
|
Shen L, Dong C, Chen J, Bai X, Yang F, Wang L. The mechanical and clinical influences of prosthetic index structure in Morse taper implant-abutment connection: a scoping review. BMC Oral Health 2023; 23:775. [PMID: 37865734 PMCID: PMC10590505 DOI: 10.1186/s12903-023-03545-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Accepted: 10/16/2023] [Indexed: 10/23/2023] Open
Abstract
AIM The implant-abutment connection is a crucial factor in determining the long-term stability of dental implants. The use of a prosthetic index structure in the Morse taper implant-abutment connection has been proposed as a potential solution to improve the accuracy of this connection. This study aimed to provide a scoping review of the mechanical and clinical effects of the prosthetic index structure in the Morse taper implant-abutment connection. METHODS A systematic scoping review of articles related to "dental implants," "Morse taper," and "index" was conducted using PubMed/MEDLINE, Web of Science, Cochrane, and Scopus databases, as well as a comprehensive literature search by two independent reviewers. Relevant articles were selected for analysis and discussion, with a specific focus on investigating the impact of prosthetic index structure on the mechanical and clinical aspects of Morse taper implant-abutment connections. RESULTS Finally, a total of 16 articles that met the inclusion criteria were included for data extraction and review. In vitro studies have demonstrated that the use of a prosthetic index structure in the Morse taper implant-abutment connection can affect stress distribution, biomechanical stability, and reverse torque values, which may reduce stress within cancellous bone and help limit crestal bone resorption. However, retrospective clinical studies have shown that this structure is also associated with a higher risk of mechanical complications, such as abutment fracture and abutment screw loosening. CONCLUSIONS Therefore, the clinical trade-off between preventing crestal bone resorption and mechanical complications must be carefully considered when selecting appropriate abutments. The findings suggest that this structure can improve the accuracy and stability of the implant-abutment connection, but its use should be carefully evaluated in clinical practice.
Collapse
Affiliation(s)
- Liheng Shen
- Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Chengzhi Dong
- Department of Stomatology, Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China
| | - Jianping Chen
- Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Xiaolei Bai
- Department of Stomatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Fan Yang
- Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China.
| | - Linhong Wang
- Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China.
| |
Collapse
|
5
|
Zhang WT, Ding YD, Wang LH, Yang F. Retrieval of a fractured implant abutment using a modified cover screw removal instrument: A clinical report. J Prosthet Dent 2023:S0022-3913(23)00543-7. [PMID: 37718179 DOI: 10.1016/j.prosdent.2023.07.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 07/26/2023] [Accepted: 07/27/2023] [Indexed: 09/19/2023]
Abstract
Implant abutment fractures are an uncommon mechanical complication, and the removal of the abutment fragment and replacement with a new prosthesis is the best solution. However, successful retrieval of the fractured abutment fragment from the implant is challenging, and effective rescue kits are lacking. This clinical report describes the retrieval of a fractured implant abutment in a conical connection implant using a modified manufacturer-specific instrument.
Collapse
Affiliation(s)
- Wen-Tao Zhang
- Attending Doctor, Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou, PR China
| | - Yu-de Ding
- Attending Doctor, Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou, PR China
| | - Lin-Hong Wang
- Associate Chief Physician, Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou, PR China
| | - Fan Yang
- Professor, Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou, PR China..
| |
Collapse
|
6
|
Zhang WT, Cheng KJ, Liu YF, Wang R, Chen YF, Ding YD, Yang F, Wang LH. Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis. BMC Oral Health 2022; 22:431. [PMID: 36180871 PMCID: PMC9523891 DOI: 10.1186/s12903-022-02465-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 09/19/2022] [Indexed: 11/23/2022] Open
Abstract
Background The combination of a prosthetic index with Morse taper connection was developed, with the purpose of making prosthetic procedures more precise. However, the presence of the index may compromise the mechanical performance of the abutment. The aim of this study is to evaluate the effect of prosthetic index on stress distribution in implant–abutment-screw system and peri-implant bone by using the 3D finite element methodology. Methods Two commercial dental implant systems with different implant–abutment connections were used: the Morse taper connection with platform switching (MT-PS) implant system and the internal hex connection with platform matching (IH-PM) implant system. Meanwhile, there are two different designs of Morse taper connection abutment, namely, abutments with or without index. Consequently, three different models were developed and evaluated: (1) MT-PS indexed, (2) MT-PS non-indexed, and (3) IH-PM. These models were inserted into a bone block. Vertical and oblique forces of 100 N were applied to each abutment to simulate occlusal loadings. Results For the MT-PS implant system, the maximum stress was always concentrated in the abutment neck under both vertical and oblique loading. Moreover, the maximum von Mises stress in the neck of the MT-PS abutment with index even exceed the yield strength of titanium alloy under the oblique loading. For the IH-PM implant system, however, the maximum stress was always located at the implant. Additionally, the MT-PS implant system has a significantly higher stress level in the abutment neck and a lower stress level around the peri-implant bone compared to the IH-PM implant system. The combined average maximum stress from vertical and oblique loads is 2.04 times higher in the MT-PS indexed model, and 1.82 times for the MT-PS non-indexed model than that of the IH-PM model. Conclusions MT-PS with index will cause higher stress concentration on the abutment neck than that of without index, which is more prone to mechanical complications. Nevertheless, MT-PS decreases stress within cancellous bone and may contribute to limiting crestal bone resorption.
Collapse
Affiliation(s)
- Wen-Tao Zhang
- Center for Plastic and Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), No. 158 Shangtang Rd., Hangzhou, 310014, China
| | - Kang-Jie Cheng
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou, 310023, China.,Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou, 310023, China.,National International Joint Research Center of Special Purpose Equipment and Advanced Processing Technology, Zhejiang University of Technology, Hangzhou, 310023, China
| | - Yun-Feng Liu
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou, 310023, China.,Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou, 310023, China.,National International Joint Research Center of Special Purpose Equipment and Advanced Processing Technology, Zhejiang University of Technology, Hangzhou, 310023, China
| | - Russell Wang
- Department of Comprehensive Care, Case Western Reserve University School of Dental Medicine, Cleveland, OH, 44106-4905, USA
| | - Yun-Fang Chen
- Center for Plastic and Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), No. 158 Shangtang Rd., Hangzhou, 310014, China
| | - Yu-de Ding
- Center for Plastic and Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), No. 158 Shangtang Rd., Hangzhou, 310014, China
| | - Fan Yang
- Center for Plastic and Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), No. 158 Shangtang Rd., Hangzhou, 310014, China.
| | - Lin-Hong Wang
- Center for Plastic and Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), No. 158 Shangtang Rd., Hangzhou, 310014, China.
| |
Collapse
|