1
|
Delucchi F, Ingegnieros L, Pesce P, Baldi D, Canullo L, Bagnasco F, Zunino P, Menini M. Efficacy and safety of erythritol air-polishing in implant dentistry: A systematic review. Int J Dent Hyg 2025; 23:44-62. [PMID: 38825804 DOI: 10.1111/idh.12836] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Revised: 05/09/2024] [Accepted: 05/11/2024] [Indexed: 06/04/2024]
Abstract
OBJECTIVES Professional oral hygiene is essential to prevent peri-implant disease. Appropriate instruments should be employed for implant-supported restorations: they should effectively remove deposits without damaging dental implant surface. The aim of the present systematic review is to investigate the efficacy and safety of erythritol air-polishing in implant-supported rehabilitations, compared to alternative hygienic techniques. MATERIALS AND METHODS The guidelines reported in the indications of the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) were employed for this systematic review. The focused question was: 'what is the effect of erythritol air-polishing on dental implant surfaces regarding its cleansing efficacy and/or safety?' The final online search was conducted on 13 August 2023; MEDLINE-PubMed, Scopus and Cochrane Library were employed. Comparative in vitro or in vivo original studies were included. RESULTS The initial database search yielded 128 entries; the final selection comprised 15 articles. The risk of bias was evaluated using the Newcastle Ottawa scale (NOS), the Cochrane Handbook for Systematic Reviews of Interventions, GRADE method. Ultrasonic scaling with PEEK tips, glycine air-polishing and cold atmospheric plasma were the devices most frequently compared to erythritol powder in the included studies. Erythritol air-polishing appeared to be significantly more effective in reducing biofilm compared to other treatments, without causing any significant damage to the implant surface and peri-implant tissues, promoting a good biological response. CONCLUSION Erythritol air-polishing showed promising results for professional oral hygiene in implant-supported restorations. According to this systematic review, it is effective and safe for removing biofilm from titanium dental implants.
Collapse
Affiliation(s)
- F Delucchi
- Division of Prosthetic Dentistry, Department of Surgical Sciences (DISC), University of Genoa, Genoa, Italy
| | - L Ingegnieros
- Division of Prosthetic Dentistry, Department of Surgical Sciences (DISC), University of Genoa, Genoa, Italy
| | - P Pesce
- Division of Prosthetic Dentistry, Department of Surgical Sciences (DISC), University of Genoa, Genoa, Italy
| | - D Baldi
- Division of Prosthetic Dentistry, Department of Surgical Sciences (DISC), University of Genoa, Genoa, Italy
| | - L Canullo
- Division of Prosthetic Dentistry, Department of Surgical Sciences (DISC), University of Genoa, Genoa, Italy
| | - F Bagnasco
- Division of Prosthetic Dentistry, Department of Surgical Sciences (DISC), University of Genoa, Genoa, Italy
| | - P Zunino
- Division of Prosthetic Dentistry, Department of Surgical Sciences (DISC), University of Genoa, Genoa, Italy
| | - M Menini
- Division of Prosthetic Dentistry, Department of Surgical Sciences (DISC), University of Genoa, Genoa, Italy
| |
Collapse
|
2
|
Khan SN, Ribeiro-Vidal H, Virto L, Bravo E, Nuevo P, Koldsland OC, Hjortsjö C, Sanz M. The Decontamination Effect of an Oscillating Chitosan Brush Compared With an Ultrasonic PEEK-Tip: An In Vitro Study Using a Dynamic Biofilm Model. Clin Oral Implants Res 2025; 36:73-81. [PMID: 39425255 DOI: 10.1111/clr.14360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 08/21/2024] [Accepted: 09/03/2024] [Indexed: 10/21/2024]
Abstract
OBJECTIVES This study aimed to assess the effect of an oscillating chitosan brush (OCB) compared with an ultrasonic device with PEEK tip (US-PEEK) for mechanical implant surface decontamination using an in vitro model combining 3D models and a validated dynamic multispecies biofilm. MATERIALS AND METHODS A multispecies biofilm using six bacterial strains (Streptococcus oralis, Veillonella parvula, Actinomyces naeslundii, Fusobacterium nucleatum, Porphyromonas gingivalis, and Aggregatibacter actinomycetemcomitans) was seeded on dental implants with machined and sandblasted, large-grit and acid-etched (SLA) surfaces. These were installed in 3D models depicting peri-implant defect. Mechanical decontamination was performed for 120 s using either an OCB or a US-PEEK. A negative control group received no treatment. Scanning electron microscopy (SEM) was used to evaluate the bacterial composition and quantitative PCR (qPCR) analyzed the number of each bacterial species [colony-forming units per milliliter (CFU/mL)]. RESULTS Well-structured biofilms with a dense microbial distribution were observed on the negative control implants after 72 h. qPCR following mechanical decontamination showed a scarce bacterial reduction in the OCB group. The US-PEEK group exhibited a significant decrease in bacterial species compared to both OCB and control groups (p < 0.05). A biofilm removal effect was also observed in the OCB group for the machined implant surfaces. CONCLUSION In vitro assessment using an anatomical 3D model showed that mechanical decontamination effectively reduced biofilm. The US-PEEK group demonstrated biofilm reduction on the SLA surface, while the OCB group showed a reduction on the machined implant surface. Additionally, the US-PEEK group demonstrated greater efficacy in reducing bacterial numbers.
Collapse
Affiliation(s)
- Sadia Nazir Khan
- Department of Prosthetics and Oral Function, Faculty of Dentistry, Institute of Clinical Dentistry, University of Oslo, Oslo, Norway
| | - Honorato Ribeiro-Vidal
- Specialization of Periodontology and Dental Implants, Faculty of Dental Medicine, University of Oporto, Porto, Portugal
- ETEP (Etiology and Therapy of Periodontal and Peri-Implant Diseases) Research Group, Faculty of Odontology, University Complutense, Madrid, Spain
| | - Leire Virto
- ETEP (Etiology and Therapy of Periodontal and Peri-Implant Diseases) Research Group, Faculty of Odontology, University Complutense, Madrid, Spain
- Department of Anatomy and Embryology, Faculty of Optics, University Complutense, Madrid, Spain
| | - Enrique Bravo
- ETEP (Etiology and Therapy of Periodontal and Peri-Implant Diseases) Research Group, Faculty of Odontology, University Complutense, Madrid, Spain
| | - Paula Nuevo
- ETEP (Etiology and Therapy of Periodontal and Peri-Implant Diseases) Research Group, Faculty of Odontology, University Complutense, Madrid, Spain
| | - Odd Carsten Koldsland
- Department of Periodontology Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo, Oslo, Norway
| | - Carl Hjortsjö
- Department of Prosthetics and Oral Function, Faculty of Dentistry, Institute of Clinical Dentistry, University of Oslo, Oslo, Norway
| | - Mariano Sanz
- ETEP (Etiology and Therapy of Periodontal and Peri-Implant Diseases) Research Group, Faculty of Odontology, University Complutense, Madrid, Spain
| |
Collapse
|
3
|
Mohamed MAF, Benjamin I, Okon GA, Ahmad I, Khan SAPM, Patel H, Agwamba EC, Louis H. Insights into in-vitro studies and molecular modelling of the antimicrobial efficiency of 4-chlorobenzaldehyde and 4-methoxybenzaldehyde derivatives. J Biomol Struct Dyn 2024; 42:6042-6064. [PMID: 37504959 DOI: 10.1080/07391102.2023.2239917] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 06/21/2023] [Indexed: 07/29/2023]
Abstract
Owing to the significant gap in the knowledge and understanding of the mechanisms of antimicrobial action and the development of resistance, the optimization of antimicrobial therapies therefore becomes a necessity. It is on this note, that this study seeks to both experimentally and theoretically investigate the antimicrobial efficiency of two synthesized compounds namely; 1-((4-methoxyphenyl) (morpholino)methyl)thiourea (MR1) and diethyl 4-(4-chlorophenyl)-2,6-diphenyl-1,4-dihydropyridine-3,5-dicarboxylate (HRC). Utilizing the density functional theory (DFT), the compounds were optimized at ωB97XD/6-31++G(2d, 2p) level of theory. This provided a clear explanation for their distinct reactivity and stability potentials. More so, the natural bond orbital (NBO) analysis confirmed strong intra and intermolecular interactions, which agreed with the calculated reactivity parameters and density of states (DOS). Upon assessing the antimicrobial efficacy of the synthesized compounds, it was found that they exhibited lower activity against Enterobacter and A. niger, but considerable activity against Moraxella. In contrast, they showed higher activity against B. subtilis and Trichophyton, indicating that the compounds are more effective against gram-positive bacteria than gram-negative ones. Hence, it can be asserted that the synthesized compounds have superior antifungal action than antibacterial activity. A fascinating aspect of the data is that they show interactions that are incredibly insightful, totally correlating with the simulations of both molecular docking and molecular dynamics. Therefore, the alignment between experimental findings and computational simulations strengthens the validity of the study's conclusions, emphasizing the significance of the synthesized compounds in the context of optimizing antimicrobial therapies.Communicated by Ramaswamy H. Sarma.
Collapse
Affiliation(s)
- Mashood A F Mohamed
- PG and Research Department of Chemistry, Jamal Mohamed College (Autonomous), Affiliated to Bharathidasan University, Tiruchirappalli, Tamilnadu, India
| | - Innocent Benjamin
- Computational and Bio-Simulation Research Group, University of Calabar, Calabar, Nigeria
- Department of Microbiology, Faculty of Biological Sciences, University of Calabar, Calabar, Nigeria
| | - Gideon A Okon
- Computational and Bio-Simulation Research Group, University of Calabar, Calabar, Nigeria
| | - Iqrar Ahmad
- Department of Pharmaceutical Chemistry, Prof. Ravindra Nikam College of Pharmacy, Dhule, Maharashtra, India
| | - Syed A P M Khan
- PG and Research Department of Chemistry, Jamal Mohamed College (Autonomous), Affiliated to Bharathidasan University, Tiruchirappalli, Tamilnadu, India
- Computational and Bio-Simulation Research Group, University of Calabar, Calabar, Nigeria
| | - Harun Patel
- Division of Computer Aided Drug Design, Department of Pharmaceutical Chemistry, R. C. Patel Institute of Pharmaceutical Education and Research, Shirpur, Maharashtra, India
| | - Ernest C Agwamba
- Computational and Bio-Simulation Research Group, University of Calabar, Calabar, Nigeria
| | - Hitler Louis
- Computational and Bio-Simulation Research Group, University of Calabar, Calabar, Nigeria
- Department of Pure and Applied Chemistry, University of Calabar, Calabar, Nigeria
- Faculty of Allied Health Sciences, Chettinad Hospital and Research Institute, Chettinad Academy of Research and Education, Kelambakkam, Tamil Nadu, India
| |
Collapse
|
4
|
Morsy MS, Hassan AAHAA, Alshawkani HA, Mattoo KA, Mathur A, Fiorillo L. Effect of Repeated Moist Heat Sterilization on Titanium Implant-Abutment Interface-An In Vitro Study. Eur J Dent 2024; 18:860-868. [PMID: 38198814 PMCID: PMC11290932 DOI: 10.1055/s-0043-1776314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2024] Open
Abstract
OBJECTIVES Sterilization eliminates microbial viability by decreasing the biological load, but likewise have the ability to deteriorate the mechanical properties of an implant material. This study intended to evaluate the effect of repeated moist heat sterilization on implant-abutment interface using two different implant systems. MATERIALS AND METHODS Forty screw-retained titanium implant-abutment combinations (fixture 3.5 ×10 mm, abutment 2 mm diameter), twenty each from Genesis (Aktiv Implant Systems, United States) and Bredent (SKY, Germany), were divided into four different groups (n = 10) and placed in a computer-aided diagnostic model. The abutments from each group were exposed to first and second autoclave cycle (121°C for 30 minutes), connected back to the fixture and analyzed under scanning electron microscope for marginal gap and surface roughness. RESULTS Genesis group showed higher marginal gaps on both sides (buccal/mesial [2.8 ± 0.47]; lingual/distal [2.8 ± 0.33]), while Bredent implant-abutment system (IAS) did not show any changes in marginal gaps after autoclaving. Differences within and between the group were found to be statistically significant. Surface roughness for Genesis (243.7 ± 70.30) and Bredent groups (528.9 ± 213.19) was highest at second autoclave, with Bredent implant-abutment showing higher values for surface roughness than Genesis IAS. CONCLUSION Marginal vertical gap increased with autoclaving for Genesis IAS, while Bredent implant abutments were more stable. Surface roughness increases with autoclaving for both Genesis and Bredent group of IAS.
Collapse
Affiliation(s)
- Mohamed S.M. Morsy
- Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, KSA
| | | | - Hamed A. Alshawkani
- Department of Restorative Dental Science, College of Dentistry, Jazan University, Jazan, KSA
| | - Khurshid A. Mattoo
- Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, KSA
| | - Ankita Mathur
- Department of Periodontology, Dr. D.Y. Patil Dental College and Hospital, Dr. D.Y. Patil Vidyapeeth, Pimpri, Pune, Maharashtra, India
| | - Luca Fiorillo
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, Messina, Italy
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, Second University of Naples, Naples, Italy
| |
Collapse
|
5
|
Zhu Y, Xu Y, Ling Z, Zhao C, Xu A, He F. The biofilm removal effect and osteogenic potential on the titanium surface by electrolytic cleaning: An in vitro comparison of electrolytic parameters and five techniques. Clin Oral Implants Res 2024; 35:454-466. [PMID: 38345170 DOI: 10.1111/clr.14245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 01/23/2024] [Accepted: 01/30/2024] [Indexed: 04/09/2024]
Abstract
OBJECTIVES To determine the optimal current and time of electrolytic cleaning (EC), compare its biofilm removal effect with generic treatments and evaluate the influence of EC to surface characteristics and osteogenic potential of SLA titanium (Ti) discs. MATERIALS AND METHODS The six-species biofilm-covered Ti discs were placed as cathodes in physiologic saline and subjected to various current and time treatments. The residual biofilms were evaluated to determine the optimal parameters. The contaminated Ti discs were randomized and treated by rotating Ti brush; ultrasonic-scaling with metal tips; ultrasonic-scaling with PEEK tips; air-polishing and EC. The residual biofilms were compared using a lipopolysaccharide kit (LPS), scanning electron microscope (SEM), confocal laser scanning microscopy and colony-forming unit counting. Non-contaminated Ti discs were treated and characterized. The bone marrow mesenchymal stem cells (BMSCs) were cultured on treated non-contaminated Ti discs. The adhesion, proliferation, alkaline phosphatase (ALP) activity and osteocalcin level of BMSCs were assessed. RESULTS The parameters at 0.6A5min were considered optimal. For LPS and SEM, EC promoted a significantly greater biofilm removal than the other groups. There were no changes in the Ti discs' colour, topography, roughness and chemical elements after EC, and the electrolysis-treated Ti discs obtained a super-hydrophilic surface. EC positively impacted the proliferation and ALP activity of BMSCs, surpassing the efficacy of alternative treatments. CONCLUSIONS EC achieves a near-complete eradication of contaminants on the SLA surface, causes no surface damage with improved hydrophilicity, and promotes the early osteogenic response of BMSCs, which makes it a promising treatment for peri-implantitis.
Collapse
Affiliation(s)
- Yun Zhu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
- Zhejiang Provincial Clinical Research Center for Oral Disease, Hangzhou, Zhejiang, China
- Key Laboratory of Oral Biomedical Research of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Yangbo Xu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
- Zhejiang Provincial Clinical Research Center for Oral Disease, Hangzhou, Zhejiang, China
- Key Laboratory of Oral Biomedical Research of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Zhaoting Ling
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
- Zhejiang Provincial Clinical Research Center for Oral Disease, Hangzhou, Zhejiang, China
- Key Laboratory of Oral Biomedical Research of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Congrui Zhao
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
- Zhejiang Provincial Clinical Research Center for Oral Disease, Hangzhou, Zhejiang, China
- Key Laboratory of Oral Biomedical Research of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Antian Xu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
- Zhejiang Provincial Clinical Research Center for Oral Disease, Hangzhou, Zhejiang, China
- Key Laboratory of Oral Biomedical Research of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Fuming He
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
- Zhejiang Provincial Clinical Research Center for Oral Disease, Hangzhou, Zhejiang, China
- Key Laboratory of Oral Biomedical Research of Zhejiang Province, Hangzhou, Zhejiang, China
| |
Collapse
|
6
|
Costa RC, Takeda TTS, Dini C, Bertolini M, Ferreira RC, Pereira G, Sacramento CM, Ruiz KGS, Feres M, Shibli JA, Barāo VAR, Souza JGS. Efficacy of a novel three-step decontamination protocol for titanium-based dental implants: An in vitro and in vivo study. Clin Oral Implants Res 2024; 35:268-281. [PMID: 38131526 DOI: 10.1111/clr.14224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 11/05/2023] [Accepted: 11/28/2023] [Indexed: 12/23/2023]
Abstract
AIM The aim of the study was to evaluate several mechanical and chemical decontamination methods associated with a newly introduced biofilm matrix disruption strategy for biofilm cleaning and preservation of implant surface features. MATERIALS AND METHODS Titanium (Ti) discs were obtained by additive manufacturing. Polymicrobial biofilm-covered Ti disc surfaces were decontaminated with mechanical [Ti curette, Teflon curette, Ti brush, water-air jet device, and Er:YAG laser] or chemical [iodopovidone (PVPI) 0.2% to disrupt the extracellular matrix, along with amoxicillin; minocycline; tetracycline; H2 O2 3%; chlorhexidine 0.2%; NaOCl 0.95%; hydrocarbon-oxo-borate-based antiseptic] protocols. The optimal in vitro mechanical/chemical protocol was then tested in combination using an in vivo biofilm model with intra-oral devices. RESULTS Er:YAG laser treatment displayed optimum surface cleaning by biofilm removal with minimal deleterious damage to the surface, smaller Ti release, good corrosion stability, and improved fibroblast readhesion. NaOCl 0.95% was the most promising agent to reduce in vitro and in vivo biofilms and was even more effective when associated with PVPI 0.2% as a pre-treatment to disrupt the biofilm matrix. The combination of Er:YAG laser followed by PVPI 0.2% plus NaOCl 0.95% promoted efficient decontamination of rough Ti surfaces by disrupting the biofilm matrix and killing remnants of in vivo biofilms formed in the mouth (the only protocol to lead to ~99% biofilm eradication). CONCLUSION Er:YAG laser + PVPI 0.2% + NaOCl 0.95% can be a reliable decontamination protocol for Ti surfaces, eliminating microbial biofilms without damaging the implant surface.
Collapse
Affiliation(s)
- Raphael Cavalcante Costa
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
| | - Thais Terumi Sadamitsu Takeda
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
| | - Caroline Dini
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
| | - Martinna Bertolini
- Department of Periodontics and Preventive Dentistry, School of Dental Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Raquel Carla Ferreira
- Department of Periodontology, Dental Research Division, Guarulhos University, Guarulhos, São Paulo, Brazil
| | - Gabriele Pereira
- Department of Periodontology, Dental Research Division, Guarulhos University, Guarulhos, São Paulo, Brazil
| | - Catharina Marques Sacramento
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
| | - Karina Gonzales S Ruiz
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
| | - Magda Feres
- Department of Periodontology, Dental Research Division, Guarulhos University, Guarulhos, São Paulo, Brazil
- Department of Oral Medicine, Infection and Immunity, Harvard School of Dental Medicine, Boston, Massachusetts, USA
| | - Jamil A Shibli
- Department of Periodontology, Dental Research Division, Guarulhos University, Guarulhos, São Paulo, Brazil
| | - Valentim A R Barāo
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
| | - Joāo Gabriel S Souza
- Department of Periodontology, Dental Research Division, Guarulhos University, Guarulhos, São Paulo, Brazil
| |
Collapse
|
7
|
Zampa EP, Kyriakidou K, Papaparaskevas J, Pepelassi E, Karoussis IK. Effect of Low-Level Laser Irradiation (810 nm) on the Proliferation and Differentiation of Osteoblast-Like Cells Cultured on SLA Titanium Discs Exposed to a Peri-implantitis Environment. J Lasers Med Sci 2023; 14:e57. [PMID: 38144939 PMCID: PMC10746885 DOI: 10.34172/jlms.2023.57] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 10/07/2023] [Indexed: 12/26/2023]
Abstract
Introduction: Elimination of inflammation and re-osseointegration are the major objectives of peri-implantitis therapy. Existing data, however, do not support any decontamination approach. Thus, the present in vitro study aims to assess whether the air-debriding decontamination method with erythritol powder restores the biocompatibility of infected titanium discs and to investigate the potent biomodulatory ability of diode laser (810 nm) irradiation to promote cell proliferation and differentiation of premature osteoblast-like cells (MG63) towards osteocytes. Methods: The experimental groups consisted of cells seeded on titanium discs exposed or not in a peri-implantitis environment with or without biomodulation. Infected discs were cleaned with airflow with erythritol powder. Cell cultures seeded on tricalcium phosphate (TCP) surfaces with or without biomodulation with a laser (810 nm) were used as controls. The study evaluated cell viability, proliferation, adhesion (SEM) at 24, 48 and 72 hours, and surface roughness changes (profilometry), as well as the effects of low-level laser therapy (LLLT) on ALP, OSC, TGF-b1, Runx2, and BMP-7 expression in MG63 cells' genetic profile on days 7, 14, and 21. Results: The MTT assay as well as the FDA/PI method revealed that cell proliferation did not show significant differences between sterile and decontaminated discs at any timepoint. SEM photographs on day 7 showed that osteoblast-like cells adhered to both sterile and disinfected surfaces, while surface roughness did not change based on amplitude parameters. The combination of airflow and LLLT revealed a biomodulated effect on the differentiation of osteoblast-like cells with regard to the impact of laser irradiation on the genetic profile of the MG63 cells. Conclusion: In all groups tested, osteoblast-like cells were able to colonize, proliferate, and differentiate, suggesting a restoration of biocompatibility of infected discs using airflow. Furthermore, photomodulation may promote the differentiation of osteoblast-like cells cultured on both sterile and disinfected titanium surfaces.
Collapse
Affiliation(s)
- Evangelia P. Zampa
- Department of Periodontology, School of Dentistry, National and Kapodistrian University of Athens, Thivon 2 Str, Goudi, 115 27, Athens, Greece
| | - Kyriaki Kyriakidou
- Department of Periodontology, School of Dentistry, National and Kapodistrian University of Athens, Thivon 2 Str, Goudi, 115 27, Athens, Greece
| | - Joseph Papaparaskevas
- Department of Microbiology, School of Medicine, National and Kapodistrian University of Athens, M.Asias 75, 115 27, Athens, Greece
| | - Eudoxie Pepelassi
- Department of Periodontology, School of Dentistry, National and Kapodistrian University of Athens, Thivon 2 Str, Goudi, 115 27, Athens, Greece
| | - Ioannis K. Karoussis
- Department of Periodontology, School of Dentistry, National and Kapodistrian University of Athens, Thivon 2 Str, Goudi, 115 27, Athens, Greece
| |
Collapse
|
8
|
Ichioka Y, Virto L, Nuevo P, Gamonal JD, Derks J, Larsson L, Sanz M, Berglundh T. Decontamination of biofilm-contaminated implant surfaces: An in vitro evaluation. Clin Oral Implants Res 2023; 34:1058-1072. [PMID: 37469250 DOI: 10.1111/clr.14136] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 06/17/2023] [Accepted: 07/04/2023] [Indexed: 07/21/2023]
Abstract
OBJECTIVES The aim of the present study was to evaluate the cleaning efficacy of two mechanical and two chemical protocols in the decontamination of implant surfaces. METHODS In total, 123 commercially available implants were mounted in plastic models mimicking peri-implant circumferential intra-bony defects. A multispecies biofilm was grown on implant surfaces. Mechanical (air-polishing (AP), rotating titanium brush (TiB)) and chemical decontamination (alkaline electrolyzed water, N-acetyl-L-cysteine) protocols were used. Cleaning efficacy in terms of residual biofilm area, chemical surface properties, and bacterial counts were analyzed by scanning electron microscopy, energy-dispersive X-ray spectroscopy, and quantitative polymerase chain reaction. RESULTS Surface decontamination protocols including use of an AP device or a rotating TiB were superior in terms of biofilm removal and in reducing atomic% of Carbon on implant surfaces when compared to methods restricted to wiping with gauze. The use of chemical agents as adjuncts to the mechanical cleaning protocols provided no relevant overall benefit over saline. No treatment modality, however, resulted in complete biofilm removal. CONCLUSION Air-polishing and rotating TiB were more effective implant surface decontamination protocols than wiping with gauzes. Use of chemical agents did not improve cleaning efficacy.
Collapse
Affiliation(s)
- Yuki Ichioka
- Department of Periodontology, Institute of Odontology, The Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden
| | - Leire Virto
- ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, Faculty of Dentistry, Complutense University, Madrid, Spain
- Department of Anatomy and Embryology, Faculty of Optics, Complutense University, Madrid, Spain
| | - Paula Nuevo
- Research Laboratory, Faculty of Odontology, Complutense University, Madrid, Spain
| | - Juan Daniel Gamonal
- ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, Faculty of Dentistry, Complutense University, Madrid, Spain
| | - Jan Derks
- Department of Periodontology, Institute of Odontology, The Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden
| | - Lena Larsson
- Department of Periodontology, Institute of Odontology, The Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden
| | - Mariano Sanz
- ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, Faculty of Dentistry, Complutense University, Madrid, Spain
| | - Tord Berglundh
- Department of Periodontology, Institute of Odontology, The Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
9
|
Korello K, Eickholz P, Zuhr O, Ratka C, Petsos H. In vitro efficacy of non-surgical and surgical implant surface decontamination methods in three different defect configurations in the presence or absence of a suprastructure. Clin Implant Dent Relat Res 2023. [PMID: 36918345 DOI: 10.1111/cid.13198] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 01/30/2023] [Accepted: 02/22/2023] [Indexed: 03/15/2023]
Abstract
OBJECTIVES Analysis of the in vitro efficacy of non-surgical and surgical dental implant surface decontamination with or without suprastructure. MATERIALS AND METHODS Three hundred and sixty implants were dipped in indelible red and distributed to 30°, 60°, or 90° angulated bone defect models. One hundred and twenty implants were used for each bone defect, 40 of which were assigned to a decontamination method (CUR: curette; SOSC: soundscaler; APA: air powder abrasion). Of these, 20 were subjected to a simulated non-surgical (NST) or surgical treatment (ST), with/without mucosa mask, of which 10 were carried out with (S+) or without (S-) suprastructure. Uncleaned implant surface was assessed by both-sided implant surface photography. Surface morphology changes were analyzed using scanning electron microscopy (SEM). RESULTS Cleaning efficacy was significantly better within NST if the suprastructure was removed (p < 0.001). No significant difference was found within ST (p = 0.304). Overall, cleaning efficacy in the order APA > SOSC>CUR decreased significantly (p < 0.0001) for both S+ and S- in NST as well as ST. Separated by NST/ST, S+/S-, defect angulation and decontamination method, only isolated significant differences in cleaning efficacy were present. Linear regression analysis revealed significant associations of remnants with the treatment approach, decontamination method, and defect angle (p < 0.0001). SEM micrographs showed serious surface damage after use of CUR and SOSC. CONCLUSIONS Suprastructure removal is an additional option to improve cleaning efficacy of non-surgical implant surface decontamination in this in vitro model.
Collapse
Affiliation(s)
- Katharina Korello
- Department of Periodontology, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt, Frankfurt, Germany.,Private Practice, Frankfurt, Germany
| | - Peter Eickholz
- Department of Periodontology, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt, Frankfurt, Germany
| | - Otto Zuhr
- Department of Periodontology, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt, Frankfurt, Germany.,Private Practice, Munich, Germany
| | | | - Hari Petsos
- Department of Periodontology, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt, Frankfurt, Germany.,Private Practice, Butzbach, Germany
| |
Collapse
|