1
|
Samà C, Longu S, Bergesio G, Samà F, Faioli A. Therapeutic adherence in patients with Obstructive Sleep Apnea Syndrome: a retrospective cohort study. Sleep Breath 2024:10.1007/s11325-024-03097-y. [PMID: 39196316 DOI: 10.1007/s11325-024-03097-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Revised: 05/03/2024] [Accepted: 06/26/2024] [Indexed: 08/29/2024]
Abstract
INTRODUCTION Obstructive Sleep Apnea Syndrome (OSAS) is a respiratory disorder characterized by repeated episodes of partial or complete airway obstruction. Continuous Positive Airway Pressure therapy (CPAP) is effective in improving sleep quality and daytime sleepiness. The aim of the study was to evaluate therapeutic adherence in a sample of patients with OSAS from the Pneumology ward of the "Cardinal Massaia" Hospital in Asti. MATERIALS AND METHODS A sample of 221 patients with OSAS were collected and retrospectively analyzed from January 2019 to December 2021. Ventilation hours during device titration (T1), possible second titration (T2) and one-year control (T3) were considered. The use of the CPAP device equal to or greater than 4 h/night was considered as therapeutic adherence. Age, gender, severity of OSAS, smoking, interface used and Epworth Sleepiness Scale (ESS) score were considered. RESULTS The analysis data showed that the percentage of adhesion during T1 was 84%. Only 9% needed T2, with 84% adherence. At T3 the adherence was 86%. Correlation studies showed that only smoking had a positive correlation with adherence, while OSAS severity, gender, ESS score, interface used and age had no statistically significant correlation. CONCLUSION It was important to understand that OSAS is a disease with prolonged treatment, which affects the life of the person and his family. Therefore, the concept of assistance network was born, which sees the healthcare operators, the person and his family as the main actors involved in a care process.
Collapse
Affiliation(s)
- Carmen Samà
- RN, Cardinal Massaia Hospital, Corso Dante Alighieri 202, Asti, 14100, Italy.
| | - Sandro Longu
- RN, Cardinal Massaia Hospital, Corso Dante Alighieri 202, Asti, 14100, Italy
| | - Giorgio Bergesio
- RN, MSN, Contract professors Nursing Degree University of Turin, Piazzale Fabrizio de Andrè, Asti, 14100, Italy
| | - Francesca Samà
- RN, Cardinal Massaia Hospital, Corso Dante Alighieri 202, Asti, 14100, Italy
| | - Alessia Faioli
- RN, Cardinal Massaia Hospital, Corso Dante Alighieri 202, Asti, 14100, Italy
| |
Collapse
|
2
|
Rubanenko AO, Dyachkov VA, Miroshnichenko AI. [Factors affecting adherence to CPAP therapy in patients with obstructive sleep apnea syndrome]. Zh Nevrol Psikhiatr Im S S Korsakova 2024; 124:58-65. [PMID: 38934667 DOI: 10.17116/jnevro202412405258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/28/2024]
Abstract
OBJECTIVE Analysis of factors affecting adherence to continuous positive airway pressure (CPAP) therapy in patients with obstructive sleep apnea (OSA). MATERIAL AND METHODS The literature search was carried out using the databases PubMED, Google Scholar, E-library, Cyberleninka for the period 2013-2023 and included reviews and original articles. RESULTS The main groups of factors affecting adherence to CPAP therapy in patients with OSA have been established. These include sociodemographic and socioeconomic factors, the severity of OSA and the severity of clinical symptoms, and psychosocial factors. Strategies that can improve adherence were identified (educational technologies for patients, telemedicine technologies, behavioral therapy, modern technical interventions). CONCLUSION Factors that improve adherence to CPAP therapy are high levels of education and income, more severe OSA forms accompanied by daytime sleepiness, support from the patient's spouse and social support. Factors such as low levels of education and income, smoking, symptoms of depression and hypochondria, as well as side-effects worsen adherence to CPAP therapy, including refusal to continue treatment. It should be noted that all the identified factors are very closely associated with each other, so it is necessary to evaluate them comprehensively in each patient with OSA.
Collapse
Affiliation(s)
- A O Rubanenko
- Samara State Medical University of the Ministry of Healthcare of the Russia, Samara, Russia
| | - V A Dyachkov
- Samara State Medical University of the Ministry of Healthcare of the Russia, Samara, Russia
| | - A I Miroshnichenko
- Samara State Medical University of the Ministry of Healthcare of the Russia, Samara, Russia
| |
Collapse
|
3
|
Clinical Decision-making for Continuous Positive Airway Pressure Mask Selection. Sleep Med Clin 2022; 17:569-576. [DOI: 10.1016/j.jsmc.2022.07.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
4
|
Martelly E, Rana S, Shimada K. Design and Fabrication of Custom-Fit BiPAP and CPAP Masks Using Three-Dimensional Imaging and Three-Dimensional Printing Techniques. J Med Device 2021. [DOI: 10.1115/1.4049981] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Abstract
Noninvasive ventilator support such as bi-level positive airway pressure (BiPAP) or continuous positive airway pressure (CPAP) is often used for patients with obstructive sleep apnea or neuromuscular disorders, such as amyotrophic lateral sclerosis (ALS), where respiratory muscles are weakened. Current commercially available masks for BiPAP and CPAP are often cited as being ill-fitting and leaky, leading to poor quality of sleep or reduced usage of therapy. This project seeks to minimize leaks and maximize comfort by developing custom-fit masks. Patient faces are imaged using an in-house camera system to obtain a three-dimensional (3D) facial contour. Custom interfaces are generated based on this contour using interactive computer software. Using 3D printing to enable rapid tooling, these interfaces are produced in a skin-safe silicone and attached to an off-the-shelf (OTS) mask to create a custom mask. The methodology has been initially tested on five healthy subjects who underwent a two-night sleep study, one night with an OTS mask and one night with a custom-fit mask, to evaluate the leakage and comfort of the custom-fit mask compared to the OTS version. Subjects filled out a questionnaire asking them about mask comfort, leakage, and quality of sleep along with open-ended questions. While the custom-fit mask did not reduce the average measured leakage for subjects, subjects reported experiencing less leakage. Overall, results suggest that the custom-fit masks are more comfortable and tolerable than the provided OTS option. Subject feedback will be implemented into future masks that will be used in a clinical study.
Collapse
Affiliation(s)
- Erica Martelly
- Department of Mechanical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA 15213
| | - Sandeep Rana
- Department of Neurology, Allegheny General Hospital, 320 E North Avenue, Pittsburgh, PA 15212
| | - Kenji Shimada
- Department of Mechanical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA 15213
| |
Collapse
|
5
|
Seo MY, Lee SH. Compliance with Continuous Positive Airway Pressure in Patients with Obstructive Sleep Apnea. SLEEP MEDICINE RESEARCH 2020. [DOI: 10.17241/smr.2020.00563] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
|
6
|
Foellner S, Guth P, Jorde I, Lücke E, Ganzert C, Stegemann-Koniszewski S, Schreiber J. Prevention of leakage due to mouth opening through applying an oral shield device (Sominpax™) during nasal CPAP therapy of patients with obstructive sleep apnea. Sleep Med 2019; 66:168-173. [PMID: 31884409 DOI: 10.1016/j.sleep.2019.06.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 06/22/2019] [Accepted: 06/24/2019] [Indexed: 11/19/2022]
Abstract
BACKGROUND/OBJECTIVE The first line treatment for obstructive sleep apnea (OSA) is nasal continuous positive airway pressure (nCPAP), for which a variety of masks are available. While nasal masks (NM) are the first choice; oronasal masks (ONM) are also frequently used to prevent mouth dryness resulting from mouth opening. Our cross-sectional, prospective, randomized, un-blinded study addressed the efficacy of wearing an oral shield in addition to NM in preventing mouth leakage METHODS: Patients with OSA and established therapy using NM and complaining about mouth dryness (n = 29) underwent three polysomnographies (PSGs) using NM, ONM or a nose mask in combination with an oral shield (NMS). Mask leakage was continuously documented and objective sleep quality was assessed. RESULTS There were significant differences in the apnea-hypopnea-index (AHI) between ONM (8.5/h; SD 6,7) and NM/nasal mask combined with oral shield device (NMS) (2.6/h; SD 2,3; 2.7/h; SD 2,6) (p < 0,05) as well as in leakage [ONM (39.7 l/min SD 12,4); NM (34.6 l/min SD 9,4); NMS (33.1 l/min SD 9,6)] (p = 0.011). Furthermore, analysis of sleep quality (NREM3) favored NM and NMS over ONM (p = 0.02). There were no significant differences between NM and NMS in any objective outcome. CONCLUSIONS Our data consistently confirmed the NM as the first choice for continuous positive airway pressure (CPAP) therapy of OSA. Notably, we demonstrated a high potential of the oral shield for patients with mouth opening to achieve additional comfort and thereby possibly compliance, without affecting nCPAP therapy effectiveness.
Collapse
Affiliation(s)
- Sebastian Foellner
- Otto - von - Guericke University Magdeburg, Dept. of Pneumonology, Centre for Sleep Medicine, Magdeburg, Germany.
| | - Patricia Guth
- Otto - von - Guericke University Magdeburg, Dept. of Pneumonology, Centre for Sleep Medicine, Magdeburg, Germany
| | - Ilka Jorde
- Otto - von - Guericke University Magdeburg, Dept. of Pneumonology, Centre for Sleep Medicine, Magdeburg, Germany
| | - Eva Lücke
- Otto - von - Guericke University Magdeburg, Dept. of Pneumonology, Centre for Sleep Medicine, Magdeburg, Germany
| | - Christine Ganzert
- Otto - von - Guericke University Magdeburg, Dept. of Pneumonology, Centre for Sleep Medicine, Magdeburg, Germany
| | - Sabine Stegemann-Koniszewski
- Otto - von - Guericke University Magdeburg, Dept. of Pneumonology, Centre for Sleep Medicine, Magdeburg, Germany
| | - Jens Schreiber
- Otto - von - Guericke University Magdeburg, Dept. of Pneumonology, Centre for Sleep Medicine, Magdeburg, Germany
| |
Collapse
|
7
|
Mehrtash M, Bakker JP, Ayas N. Predictors of Continuous Positive Airway Pressure Adherence in Patients with Obstructive Sleep Apnea. Lung 2019; 197:115-121. [PMID: 30617618 DOI: 10.1007/s00408-018-00193-1] [Citation(s) in RCA: 119] [Impact Index Per Article: 23.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Accepted: 12/29/2018] [Indexed: 01/23/2023]
Abstract
Obstructive sleep apnea (OSA) is a common disease which impacts quality of life, mood, cardiovascular morbidity, and mortality. Continuous positive airway pressure (CPAP) is the first-line treatment for patients with moderate to severe OSA. CPAP ameliorates respiratory disturbances, leading to improvements in daytime sleepiness, quality of life, blood pressure, and cognition. However, despite the high efficacy of this device, CPAP adherence is often sub-optimal. Factors including: socio-demographic/economic characteristics, disease severity, psychological factors, and side-effects are thought to affect CPAP adherence in OSA patients. Intervention studies have suggested that augmented support/education, behavioral therapy, telemedicine and technological interventions may improve CPAP adherence. In this paper, we will extensively review the most common factors including age, gender, race/ethnicity, socioeconomic status, smoking status, severity of OSA, severity of OSA symptoms, psychological variables, social support, marital status/bed partner involvement, dry nose and mouth, mask leak, and nasal congestion that may predict CPAP adherence. We will also extensively review interventions that may increase adherence to CPAP.
Collapse
Affiliation(s)
- M Mehrtash
- Experimental Medicine Program, Department of Medicine, University of British Columbia (UBC), Vancouver, BC, Canada
- Sleep Disorders Program, UBC Hospital, Vancouver, BC, Canada
| | - J P Bakker
- Division of Sleep & Circadian Disorders, Brigham and Women's Hospital, Boston, MA, USA
| | - N Ayas
- Sleep Disorders Program, UBC Hospital, Vancouver, BC, Canada.
- Respiratory and Critical Care Divisions, Department of Medicine, UBC, Vancouver, BC, Canada.
| |
Collapse
|
8
|
Conti G, Spinazzola G, Gregoretti C, Ferrone G, Cortegiani A, Festa O, Piastra M, Tortorolo L, Costa R. Comparative bench study evaluation of different infant interfaces for non-invasive ventilation. BMC Pulm Med 2018; 18:57. [PMID: 29625596 PMCID: PMC5889592 DOI: 10.1186/s12890-018-0620-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2017] [Accepted: 03/29/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND To compare, in terms of patient-ventilator interaction and performance, a new nasal mask (Respireo, AirLiquide, FR) with the Endotracheal tube (ET) and a commonly used nasal mask (FPM, Fisher and Paykel, NZ) for delivering Pressure Support Ventilation (PSV) in an infant model of Acute Respiratory Failure (ARF). METHODS An active test lung (ASL 5000) connected to an infant mannequin through 3 different interfaces (Respireo, ET and FPM), was ventilated with a standard ICU ventilator set in PSV. The test lung was set to simulate a 5.5 kg infant with ARF, breathing at 50 and 60 breaths/min). Non-invasive ventilation (NIV) mode was not used and the leaks were nearly zero. RESULTS The ET showed the shortest inspiratory trigger delay and pressurization time compared to FPM and Respireo (p < 0.01). At each respiratory rate tested, the FPM showed the shortest Expiratory trigger delay compared to ET and Respireo (p < 0.01). The Respireo presented a lower value of Inspiratory pressure-time product and trigger pressure drop than ET (p < 0.01), while no significant difference was found in terms of pressure-time product at 300 and 500 ms. During all tests, compared with the FPM, ET showed a significantly higher tidal volume (VT) delivered (p < 0.01), while Respireo showed a trend toward an increase of tidal volume delivered compared with FPM. CONCLUSIONS The ET showed a better patient-ventilator interaction and performance compared to both the nasal masks. Despite the higher internal volume, Respireo showed a trend toward an increase of the delivered tidal volume; globally, its efficiency in terms of patient-ventilator interaction was comparable to the FPM, which is the infant NIV mask characterized by the smaller internal volume among the (few) models on the market.
Collapse
Affiliation(s)
- Giorgio Conti
- Intensive Care and Anaesthesia Department and Ventilab, Catholic University of Rome, Policlinico A. Gemelli, Largo Agostino Gemelli 8, 00168, Rome, Italy
| | - Giorgia Spinazzola
- Intensive Care and Anaesthesia Department and Ventilab, Catholic University of Rome, Policlinico A. Gemelli, Largo Agostino Gemelli 8, 00168, Rome, Italy
| | - Cesare Gregoretti
- Department of Biopathology and Medical Biotechnologies (DIBIMED), Section of Anesthesia, Analgesia, Intensive Care and Emergency. Policlinico Paolo Giaccone, University of Palermo, Via del vespro 129, 90127, Palermo, Italy
| | - Giuliano Ferrone
- Intensive Care and Anaesthesia Department and Ventilab, Catholic University of Rome, Policlinico A. Gemelli, Largo Agostino Gemelli 8, 00168, Rome, Italy
| | - Andrea Cortegiani
- Department of Biopathology and Medical Biotechnologies (DIBIMED), Section of Anesthesia, Analgesia, Intensive Care and Emergency. Policlinico Paolo Giaccone, University of Palermo, Via del vespro 129, 90127, Palermo, Italy.
| | - Olimpia Festa
- Intensive Care and Anaesthesia Department and Ventilab, Catholic University of Rome, Policlinico A. Gemelli, Largo Agostino Gemelli 8, 00168, Rome, Italy
| | - Marco Piastra
- Intensive Care and Anaesthesia Department and Ventilab, Catholic University of Rome, Policlinico A. Gemelli, Largo Agostino Gemelli 8, 00168, Rome, Italy
| | - Luca Tortorolo
- Intensive Care and Anaesthesia Department and Ventilab, Catholic University of Rome, Policlinico A. Gemelli, Largo Agostino Gemelli 8, 00168, Rome, Italy
| | - Roberta Costa
- Intensive Care and Anaesthesia Department and Ventilab, Catholic University of Rome, Policlinico A. Gemelli, Largo Agostino Gemelli 8, 00168, Rome, Italy
| |
Collapse
|
9
|
Lan MC, Hsu YB, Lan MY, Huang YC, Kao MC, Huang TT, Chiu TJ, Yang MC. The predictive value of drug-induced sleep endoscopy for CPAP titration in OSA patients. Sleep Breath 2017; 22:949-954. [DOI: 10.1007/s11325-017-1600-8] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2017] [Revised: 11/23/2017] [Accepted: 11/29/2017] [Indexed: 12/12/2022]
|
10
|
Lebret M, Martinot JB, Arnol N, Zerillo D, Tamisier R, Pepin JL, Borel JC. Factors Contributing to Unintentional Leak During CPAP Treatment: A Systematic Review. Chest 2016; 151:707-719. [PMID: 27986462 DOI: 10.1016/j.chest.2016.11.049] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Revised: 11/09/2016] [Accepted: 11/29/2016] [Indexed: 12/30/2022] Open
Abstract
CPAP is the first-line treatment for moderate to severe OSA syndrome. Up to 25% of patients with OSA syndrome discontinue CPAP treatment due to side effects. Unintentional leakage and its associated annoying consequences are the most frequently reported adverse effects of CPAP. Successive technological improvements have not succeeded in addressing this issue. A systematic review was conducted (1) to assess the impact of different technological advances on unintentional leaks and (2) to determine if any patient characteristics have already been identified as determinants of unintentional leakage. No CPAP modality was superior to another in reducing unintentional leaks and, surprisingly, oronasal masks were associated with higher unintentional leaks. Nasal obstruction, older age, higher BMI, central fat distribution, and male sex might be associated with an increased risk of unintentional leakage. Such leaks remain an important problem. Further studies are needed to improve the understanding of underlying clinical factors so that patients at risk of unintentional leaks may be identified and individualized solutions applied.
Collapse
Affiliation(s)
- Marius Lebret
- Department of Research and Development, Association AGIR à dom, HP2 Laboratory, INSERM U 1042, Meylan, France.
| | | | - Nathalie Arnol
- Department of Research and Development, Association AGIR à dom, HP2 Laboratory, INSERM U 1042, Meylan, France
| | - Daniel Zerillo
- Department of Research and Development, Association AGIR à dom, HP2 Laboratory, INSERM U 1042, Meylan, France
| | - Renaud Tamisier
- Thorax and Vessels Division, Sleep Laboratory, Grenoble Alpes University, HP2 Laboratory, INSERM U 1042, Grenoble, France
| | - Jean-Louis Pepin
- Thorax and Vessels Division, Sleep Laboratory, Grenoble Alpes University, HP2 Laboratory, INSERM U 1042, Grenoble, France
| | - Jean-Christian Borel
- Department of Research and Development, Association AGIR à dom, HP2 Laboratory, INSERM U 1042, Meylan, France; Thorax and Vessels Division, Sleep Laboratory, Grenoble Alpes University, HP2 Laboratory, INSERM U 1042, Grenoble, France
| |
Collapse
|
11
|
Impact of a New Nasal Pillows Mask on Patients' Acceptance, Compliance, and Willingness to Remain on CPAP Therapy. SLEEP DISORDERS 2016; 2016:6713236. [PMID: 27648308 PMCID: PMC5014980 DOI: 10.1155/2016/6713236] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Accepted: 08/09/2016] [Indexed: 12/03/2022]
Abstract
Aim. Continuous positive airway pressure (CPAP) masks are a key factor in patient compliance. This program assessed the performance of a new nasal pillows mask (NPM) on a variety of new and established obstructive sleep apnea (OSA) patients using CPAP therapy. Methods. Five programs were developed to assess the new NPM [AirFit P10, ResMed] on naïve patients; patients established on another NPM; patients using a nasal mask; patients with low CPAP compliance; and patients who wished to stop using CPAP therapy. Results. A total of 212 patients were included. In naïve patients, CPAP usage after 3 months was 5.9 ± 1.7 hours/night, compared with the control group at 4.6 ± 2.4 hours/night (p < 0.05). In patients established on another NPM, usage improved to 7.4 ± 1.1 hours/night versus 6.7 ± 1.4 (p = 0.001). 78% of nasal mask users wished to continue using the new NPM. Low compliance patients improved with an average of 0.87 hours/night (p = 0.001) when using the new NPM. In patients at the point of quitting CPAP, 60% continued with therapy using the new NPM. Conclusion. The new NPM mask performed well in a variety of clinical groups of OSA patients receiving CPAP therapy and shows that technical advances in CPAP masks can improve patient compliance.
Collapse
|