1
|
Yang X, Gao H, Fu S, Ji R, Hou C, Liu H, Luan N, Ren H, Sun L, Yang J, Zhou Z, Yang X, Sun L, Li Y, Zuo X. Novel miniature transendoscopic telerobotic system for endoscopic submucosal dissection (with videos). Gastrointest Endosc 2024; 99:155-165.e4. [PMID: 37820930 DOI: 10.1016/j.gie.2023.10.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Revised: 09/10/2023] [Accepted: 10/03/2023] [Indexed: 10/13/2023]
Abstract
BACKGROUND AND AIMS The lack of tissue traction and instrument dexterity to allow for adequate visualization and effective dissection were the main issues in performing endoscopic submucosal dissection (ESD). Robot-assisted systems may provide advantages. In this study we developed a novel transendoscopic telerobotic system and evaluated its performance in ESD. METHODS A miniature dual-arm robotic endoscopic assistant for minimally invasive surgery (DREAMS) was developed. The DREAMS system contained the current smallest robotic ESD instruments and was compatible with the commercially available dual-channel endoscope. After the system was established, a prospective randomized controlled study was conducted to validate the performance of the DREAMS-assisted ESD in terms of efficacy, safety, and workload by comparing it with the conventional technique. RESULTS Two robotic instruments can achieve safe collaboration and provide sufficient visualization and efficient dissection during ESD. Forty ESDs in the stomach and esophagus of 8 pigs were completed by DREAMS-assisted ESD or conventional ESD. Submucosal dissection time was comparable between the 2 techniques, but DREAMS-assisted ESD demonstrated a significantly lower muscular injury rate (15% vs 50%, P = .018) and workload scores (22.30 vs 32.45, P < .001). In the subgroup analysis of esophageal ESD, DREAMS-assisted ESD showed significantly improved submucosal dissection time (6.45 vs 16.37 minutes, P = .002), muscular injury rate (25% vs 87.5%, P = .041), and workload (21.13 vs 40.63, P = .001). CONCLUSIONS We developed a novel transendoscopic telerobotic system, named DREAMS. The safety profile and technical feasibility of ESD were significantly improved with the assistance of the DREAMS system, especially in the narrower esophageal lumen.
Collapse
Affiliation(s)
- Xiaoxiao Yang
- Department of Gastroenterology, Qilu Hospital of Shandong University, Jinan, China
| | - Huxin Gao
- Depart of Biomedical Engineering, National University of Singapore, Singapore; NUS (Suzhou) Research Institute, Suzhou, China; Department of Electronic Engineering and the Shun Hing Institute of Advanced Engineering, The Chinese University of Hong Kong, Hong Kong
| | - Shichen Fu
- Department of Gastroenterology, Qilu Hospital of Shandong University, Jinan, China
| | - Rui Ji
- Department of Gastroenterology, Qilu Hospital of Shandong University, Jinan, China
| | - Cheng Hou
- School of Mechanical and Electric Engineering, Jiangsu Provincial Key Laboratory of Advanced Robotics, Soochow University, Suzhou, China
| | - Huicong Liu
- School of Mechanical and Electric Engineering, Jiangsu Provincial Key Laboratory of Advanced Robotics, Soochow University, Suzhou, China
| | - Nan Luan
- The School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Hongliang Ren
- Depart of Biomedical Engineering, National University of Singapore, Singapore; NUS (Suzhou) Research Institute, Suzhou, China; Department of Electronic Engineering and the Shun Hing Institute of Advanced Engineering, The Chinese University of Hong Kong, Hong Kong
| | - Liping Sun
- Faculty of Medical Instrumentation, Shanghai University of Medicine & Health Sciences, Shanghai, China
| | - Jialin Yang
- Robo Medical Technology Co, Ltd, Shenzhen, China
| | - Zhifeng Zhou
- Huaco Healthcare Technologies Co Ltd, Beijing, China
| | - Xiaoyun Yang
- Department of Gastroenterology, Qilu Hospital of Shandong University, Jinan, China
| | - Lining Sun
- School of Mechanical and Electric Engineering, Jiangsu Provincial Key Laboratory of Advanced Robotics, Soochow University, Suzhou, China
| | - Yanqing Li
- Department of Gastroenterology, Qilu Hospital of Shandong University, Jinan, China; Robot Engineering Laboratory for Precise Diagnosis and Therapy of GI Tumor, Qilu Hospital of Shandong University, Jinan, China; Laboratory of Translational Gastroenterology, Qilu Hospital of Shandong University, Jinan, China
| | - Xiuli Zuo
- Department of Gastroenterology, Qilu Hospital of Shandong University, Jinan, China; Robot Engineering Laboratory for Precise Diagnosis and Therapy of GI Tumor, Qilu Hospital of Shandong University, Jinan, China; Laboratory of Translational Gastroenterology, Qilu Hospital of Shandong University, Jinan, China
| |
Collapse
|
2
|
Takada K, Yoshida M. Simple add-on robotic traction device to the conventional endoscope: Will it be an efficient and safe tool for novice training on endoscopic submucosal dissection? Dig Endosc 2023; 35:352-353. [PMID: 36442840 DOI: 10.1111/den.14471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Accepted: 11/08/2022] [Indexed: 11/30/2022]
Affiliation(s)
- Kazunori Takada
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Masao Yoshida
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| |
Collapse
|