1
|
Szmidel M, Hunn M, Neal A, Laing J, Broadley L, Wittayacharoenpong T, O'brien T, Gutman M. Vascular imaging for Stereoelectroencephalography: A safety and planning study. J Clin Neurosci 2024; 127:110762. [PMID: 39079420 DOI: 10.1016/j.jocn.2024.110762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 06/30/2024] [Accepted: 07/19/2024] [Indexed: 08/23/2024]
Abstract
BACKGROUND Stereoelectroencephalography (SEEG) is a procedure used to localize the epileptogenic zone in patients with medically refractory epilepsy, involving the stereotactic implantation of electrodes into brain parenchyma. Magnetic Resonance Imaging (MRI), Digital Subtraction Angiography, and Computed Tomography have been used preoperatively to prevent Intracranial Hemorrhage (ICH) by identifying electrode-vessel conflicts (EVC's) on planned electrode trajectories. There is variation in the use of Digital Subtraction Angiography and non-invasive sequences for vascular planning. Digital Subtraction Angiography provides high spatial resolution, but carries risks of arterial dissection, groin and retroperitoneal hematoma, and a 0.5-1.9% risk of stroke. Our group has incorporated Intravenous Cone Beam Computed Tomography (CBCT A/V) Brain into our SEEG workflow, given its effective implementation in other neurosurgical domains. Primary aims include validating the safety of our CBCT A/V sequence for SEEG planning and determining if CBCT A/V is comparable to other modalities in detecting EVC's. Secondary aims include elucidating the relationship of conflicting vessel calibre with ICH incidence in SEEG using CBCT A/V imaging. METHODS A single-center retrospective study was conducted of 20 patients who underwent preoperative CBCT A/V Brain and MRI Brain with gadolinium enhancement, encompassing 273 electrode implantations from August 2020 - July 2023. The incidence and grade of post-implant, post-explant symptomatic ICH and asymptomatic ICH was noted. The total number of EVC's identifiable on MRI and CBCT A/V was recorded, along with average diameter of conflicting vessels. RESULTS Across 20 patients and 273 implanted electrodes, there were four ICH events, where two were symptomatic and two were asymptomatic. The mean diameter of EVC's across all patients was 1.4 mm (±0.5). A significant difference (P < 0.0001) was observed between the number of EVC's that CBCT A/V could identify (20) compared to MRI (6). Two EVC's were identified in the region of two symptomatic ICH's, with the mean diameter of these conflicted vessels being 1.5 mm (±0.4). The two symptomatic ICH-associated EVC's were observed on CBCT A/V but not MRI. CONCLUSIONS In our series, CBCT A/V demonstrates an acceptable safety profile for SEEG planning compared to other imaging modalities. CBCT A/V identified significantly more EVC's compared to MRI, including those contributing to transient symptomatic intracranial hemorrhage. A conflicting vessel calibre of less than 1.2 mm on CBCT A/V did not contribute to ICH in our SEEG series.
Collapse
Affiliation(s)
- Matthew Szmidel
- Department of Neurosurgery, Alfred Hospital, Melbourne, VIC, Australia; Department of Neuroscience, Alfred Hospital, Melbourne, VIC, Australia; Monash University, VIC, Australia.
| | - Martin Hunn
- Department of Neurosurgery, Alfred Hospital, Melbourne, VIC, Australia.
| | - Andrew Neal
- Department of Neuroscience, Alfred Hospital, Melbourne, VIC, Australia; Epilepsy Unit, Alfred Hospital, Melbourne, VIC, Australia.
| | - Joshua Laing
- Department of Neuroscience, Alfred Hospital, Melbourne, VIC, Australia; Epilepsy Unit, Alfred Hospital, Melbourne, VIC, Australia; The University of Melbourne, VIC, Australia.
| | - Lisa Broadley
- Department of Radiology, Alfred Hospital, Melbourne, VIC, Australia.
| | | | - Terence O'brien
- Department of Neuroscience, Alfred Hospital, Melbourne, VIC, Australia.
| | - Matthew Gutman
- Department of Neurosurgery, Alfred Hospital, Melbourne, VIC, Australia; Department of Neuroscience, Alfred Hospital, Melbourne, VIC, Australia; Monash University, VIC, Australia.
| |
Collapse
|
2
|
Dai Y, Jiang R, Zhang J, Qian Z, Chen Z, Shi S, Song S. The Value of SINO Robot and Angio Render Technology for Stereoelectroencephalography Electrode Implantation in Drug-Resistant Epilepsy. J Neurol Surg A Cent Eur Neurosurg 2024. [PMID: 38574755 DOI: 10.1055/a-2299-7781] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/06/2024]
Abstract
BACKGROUND Stereoelectroencephalography (SEEG) electrodes are implanted using a variety of stereotactic technologies to treat refractory epilepsy. The value of the SINO robot for SEEG electrode implantation is not yet defined. The aim of the current study was to assess the value of the SINO robot in conjunction with Angio Render technology for SEEG electrode implantation and to assess its efficacy. METHODS Between June 2018 and October 2020, 58 patients underwent SEEG electrode implantation to resect or ablate their epileptogenic zone (EZ). The SINO robot and the Angio Render technology was used to guide the electrodes and visualize the individual vasculature in a three-dimensional (3D) fashion. The 3D view functionality was used to increase the safety and accuracy of the electrode implantation, and for reducing the risk of hemorrhage by avoiding blood vessels. RESULTS In this study, 634 SEEG electrodes were implanted in 58 patients, with a mean of 10.92 (range: 5-18) leads per patient. The mean entry point localization error (EPLE) was 0.94 ± 0.23 mm (range: 0.39-1.63 mm), and the mean target point localization error (TPLE) was 1.49 ± 0.37 mm (range: 0.80-2.78 mm). The mean operating time per lead (MOTPL) was 6. 18 ± 1.80 minutes (range: 3.02-14.61 minutes). The mean depth of electrodes was 56.96 ± 3.62 mm (range: 27.23-124.85 mm). At a follow-up of at least 1 year, in total, 81.57% (47/58) patients achieved an Engel class I seizure freedom. There were two patients with asymptomatic intracerebral hematomas following SEEG electrode placement, with no late complications or mortality in this cohort. CONCLUSIONS The SINO robot in conjunction with Angio Render technology-in SEEG electrode implantation is safe and accurate in mitigating the risk of intracranial hemorrhage in patients suffering from drug-resistant epilepsy.
Collapse
Affiliation(s)
- Yihai Dai
- Department of Neurosurgery, Fujian Medical University Union Hospital, Fuzhou, Fujian, China
| | - Rifeng Jiang
- Department of Imaging, Fujian Medical University Union Hospital, Fuzhou, Fujian, China
| | - Jingyi Zhang
- Department of Neurosurgery, Fujian Medical University Union Hospital, Fuzhou, Fujian, China
| | - Zhe Qian
- Department of Neurosurgery, Fujian Medical University Union Hospital, Fuzhou, Fujian, China
| | - Zhen Chen
- Department of Neurosurgery, Fujian Medical University Union Hospital, Fuzhou, Fujian, China
| | - Songsheng Shi
- Department of Neurosurgery, Fujian Medical University Union Hospital, Fuzhou, Fujian, China
| | - Shiwei Song
- Department of Neurosurgery, Fujian Medical University Union Hospital, Fuzhou, Fujian, China
| |
Collapse
|
3
|
Liu Q, Lin Z, Shen Y, Zhu J, Song J, Zhang C, Lu Y, Xu J. Use of Compressed Sensing Accelerated, Low-Velocity Encoded, Isotropic Resolution, Phase Contrast Magnetic Resonance Angiography for SEEG Electrode Implantation. World Neurosurg 2024; 181:e18-e28. [PMID: 36791880 DOI: 10.1016/j.wneu.2023.02.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 02/05/2023] [Accepted: 02/06/2023] [Indexed: 02/15/2023]
Abstract
OBJECTIVE We assessed the feasibility of using compressed sensing accelerated, low-velocity encoded, isotropic resolution phase contrast (CLIP) magnetic resonance angiography (MRA) for avascular trajectory planning of stereoelectroencephalography. METHODS Ten healthy subjects (1 woman and 9 men; age, 33.6 ± 9.0 years) and 20 consecutive patients (12 female patients; age, 22 ± 13.6 years) were enrolled in the present study. The healthy subjects underwent CLIP-MRA, and 3 other phase contrast MRA protocols with conventional parallel imaging (PI) acceleration, including low resolution with twofold PI (PI2), high resolution (HR) with fivefold PI (PI5), and HR-PI2. The patients underwent CLIP-MRA and computed tomography angiography (CTA). The image qualities were evaluated. The numbers and locations of trajectory-vessel conflict detected using CLIP-MRA were noted. RESULTS With similar scan durations, CLIP-MRA achieved higher spatial resolution compared with low resolution with PI2 and detected significantly more branches compared with HR-PI5. With the same spatial resolution, the signal/noise and contrast/noise ratios of CLIP-MRA were higher than those with HR-PI2 with a shorter scan duration. For the 12 adult patients (10 female patients; 28.8 ± 12.7 years), CLIP-MRA had better signal/noise and contrast/noise ratios than CTA. The trajectory had required modification for 14 of the 20 patients (70%), with a proportion of trajectory modification of 10.7% (23 of 215 electrodes). The middle meningeal artery, cortical vessel, and skull vessel were the main vessels with conflict (n = 11, n = 7, and n = 5, respectively). CONCLUSIONS In the present study, CLIP-MRA provided a clear cortical vascular display noninvasively without intravascular contrast and radiation. The middle meningeal artery and diploic and emissary veins were the main conflict vessels and could be clearly displayed using CLIP-MRA but not CTA.
Collapse
Affiliation(s)
- Qiangqiang Liu
- Clinical Neuroscience Center Comprehensive Epilepsy Unit, Department of Neurosurgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China; Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Zengping Lin
- United Imaging Healthcare Group, Shanghai, People's Republic of China
| | - Yiwen Shen
- Department of Radiology, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Jiachen Zhu
- United Imaging Healthcare Group, Shanghai, People's Republic of China
| | - Jian Song
- Wuhan United Imaging Healthcare Surgical Technology Co., Ltd., Wuhan, People's Republic of China
| | - Chencheng Zhang
- Department of Neurosurgery, Center for Functional Neurosurgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Yong Lu
- Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Jiwen Xu
- Clinical Neuroscience Center Comprehensive Epilepsy Unit, Department of Neurosurgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China; Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China.
| |
Collapse
|
4
|
Wang M, Wang J, Zhang X, Chai S, Cai Y, Dai X, Yang B, Liu W, Lu T, Mei Z, Zheng Z, Zhou Y, Yang J, Shen L, Zhao J, Ho J, Cai M, Chen J, Xiong N. Intraoperative Findings of Inferior Petrosal Vein During Microvascular Decompression for Hemifacial Spasm: A Single-Surgeon Experience. Front Surg 2022; 9:921589. [PMID: 35756473 PMCID: PMC9226572 DOI: 10.3389/fsurg.2022.921589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2022] [Accepted: 05/24/2022] [Indexed: 11/13/2022] Open
Abstract
Objective This study aims to evaluate the impact of the inferior petrosal veins (IPVs) on operational exploration and to analyze related anatomic features. Methods A total of 317 patients were retrospectively studied. Surgical outcomes and postoperative complications were analyzed, and patients were divided into two groups according to whether the IPV was sacrificed or preserved. The diameter of the IPV was also recorded during operation. Furthermore, the position where the IPV drained into the jugular bulb was recorded in each patient, and the influence of different injection points on the operation was analyzed. Results IPVs were conclusively identified in 242/317 (76.3%) of patients, with 110/242 (45.5%) of patients categorized as “IPV sacrifice” versus 132/242 (54.5%) categorized as “IPV preservation.” IPV diameter was observed to be <0.5 mm in 58 cases (23.9%), 0.5 mm–1.0 mm (≥0.5 mm and ≤1.0 mm) in 145 cases (59.9%), and >1 mm in 39 cases (16.2%). The position of IPV drainage into the jugular bulb was at the level of the accessory nerve in 163 cases (67.3%), the level of the vagus nerve in 42 cases (17.4%), and the level of the glossopharyngeal nerve or above in 37 cases (15.3%). The diameters of IPV in the sacrifice group were mainly less than 1 mm (94.5% vs. 75%, P < 0.01), and the cases with draining points near the glossopharyngeal nerve were more than that in the preservation group (27.3% vs. 5.3%, P < 0.01). Conclusion IPV is an obstructive structure in MVD for HFS, with considerable variations in diameters and draining points. IPV near the glossopharyngeal nerve significantly impacts surgical exposure and is often sacrificed for a better view of the operation field. Meanwhile, it is feasible to maintain IPVs with a diameter >1 mm.
Collapse
Affiliation(s)
- Mengyang Wang
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Jiajing Wang
- Department of Neurosurgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xiuling Zhang
- Department of Neurology, Xiaogan Hospital Affiliated to Wuhan University of Science and Technology, Xiaogan, China
| | - Songshan Chai
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Yuankun Cai
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Xuan Dai
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Bangkun Yang
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Wen Liu
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Taojunjin Lu
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Zhimin Mei
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Zhixin Zheng
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - YiXuan Zhou
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Jingyi Yang
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Lei Shen
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Jingwei Zhao
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Joshua Ho
- School of Biomedical Sciences, LKS Faculty of Medicine, Hongkong University, Hongkong, China
| | - Meng Cai
- iRegene Therapeutics Ltd., Wuhan, Hongkong, China
| | - Jincao Chen
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China
- Correspondence: Jincao Chen Nanxiang Xiong
| | - Nanxiang Xiong
- Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China
- Correspondence: Jincao Chen Nanxiang Xiong
| |
Collapse
|
5
|
Wu YX, Xiang W, Wang JJ, Liu XM, Yi DY, Tian H, Zhao HY, Jiang XB, Fu P. A Modified Dura Puncture Procedure to Reduce Brain Shift in Deep Brain Stimulation Surgery: One Institution's Experience. Front Neurol 2022; 13:845926. [PMID: 35295828 PMCID: PMC8920348 DOI: 10.3389/fneur.2022.845926] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 01/31/2022] [Indexed: 11/15/2022] Open
Abstract
Objective The therapeutic effect of deep brain stimulation (DBS) surgery mainly depends on the accuracy of electrode placement and the reduction in brain shift. Among the standard procedures, cerebrospinal fluid (CSF) loss or pneumocephalus caused by dura incision (DI) is thought to be the main reason for brain shift and inaccuracy of electrode placement. In the current study, we described a modified dura puncture (DP) procedure to reduce brain shift and compare it with the general procedure of DBS surgery in terms of electrode placement accuracy. Materials and Methods We retrospectively analyzed a series of 132 patients who underwent DBS surgery in Wuhan Union Hospital from December 2015 to April 2021. According to the different surgery procedures, patients were classified into two cohorts: the DI group (DI cohort) had 49 patients who receive the general procedure, and the DP group (DP cohort) had 83 patients who receive the modified procedure. Postoperative pneumocephalus volume (PPV) and CSF loss volume, electrode fusion error (EFE), and trajectory number were calculated. Meanwhile, intraoperative electrophysiological signal length (IESL), electrode implantation duration, and other parameters were analyzed. Results In the current study, we introduced an improved electrode implantation procedure for DBS surgery named the DP procedure. Compared with the general DI cohort (n = 49), the modified DP cohort (n = 83) had a shorter electrode implantation duration (p < 0.0001), smaller PPV, lower CSF leakage volume (p < 0.0001), and smaller EFE (p < 0.0001). There was no significant difference in IESL (p > 0.05) or adverse events (perioperative cerebral haematoma, skin erosion, epilepsy, p > 0.05) between the two cohorts. Conclusion The DP procedure is a modified procedure that can reduce brain shift and ensure implantation accuracy during DBS surgery without adverse events.
Collapse
Affiliation(s)
- Yu-Xi Wu
- Department of Neurosurgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Wei Xiang
- Department of Neurosurgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Jia-Jing Wang
- Department of Neurosurgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xiao-Ming Liu
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Dong-Ye Yi
- Department of Neurosurgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Han Tian
- Department of Neurosurgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Hong-Yang Zhao
- Department of Neurosurgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xiao-Bing Jiang
- Department of Neurosurgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Peng Fu
- Department of Neurosurgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
- *Correspondence: Peng Fu
| |
Collapse
|
6
|
Dang VN, Galati F, Cortese R, Di Giacomo G, Marconetto V, Mathur P, Lekadir K, Lorenzi M, Prados F, Zuluaga MA. Vessel-CAPTCHA: An efficient learning framework for vessel annotation and segmentation. Med Image Anal 2021; 75:102263. [PMID: 34731770 DOI: 10.1016/j.media.2021.102263] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 10/04/2021] [Accepted: 10/06/2021] [Indexed: 12/22/2022]
Abstract
Deep learning techniques for 3D brain vessel image segmentation have not been as successful as in the segmentation of other organs and tissues. This can be explained by two factors. First, deep learning techniques tend to show poor performances at the segmentation of relatively small objects compared to the size of the full image. Second, due to the complexity of vascular trees and the small size of vessels, it is challenging to obtain the amount of annotated training data typically needed by deep learning methods. To address these problems, we propose a novel annotation-efficient deep learning vessel segmentation framework. The framework avoids pixel-wise annotations, only requiring weak patch-level labels to discriminate between vessel and non-vessel 2D patches in the training set, in a setup similar to the CAPTCHAs used to differentiate humans from bots in web applications. The user-provided weak annotations are used for two tasks: (1) to synthesize pixel-wise pseudo-labels for vessels and background in each patch, which are used to train a segmentation network, and (2) to train a classifier network. The classifier network allows to generate additional weak patch labels, further reducing the annotation burden, and it acts as a second opinion for poor quality images. We use this framework for the segmentation of the cerebrovascular tree in Time-of-Flight angiography (TOF) and Susceptibility-Weighted Images (SWI). The results show that the framework achieves state-of-the-art accuracy, while reducing the annotation time by ∼77% w.r.t. learning-based segmentation methods using pixel-wise labels for training.
Collapse
Affiliation(s)
- Vien Ngoc Dang
- Data Science Department, EURECOM, Sophia Antipolis, France; Artificial Intelligence in Medicine Lab, Facultat de Matemátiques I Informática, Universitat de Barcelona, Spain
| | | | - Rosa Cortese
- Queen Square MS Centre, Department of Neuroinflammation, UCL Queen Square Institute of Neurology, Faculty of Brain Sciences, University College London, UK; Department of Medicine, Surgery and Neuroscience, University of Siena, Italy
| | - Giuseppe Di Giacomo
- Data Science Department, EURECOM, Sophia Antipolis, France; Politecnico di Torino, Turin, Italy
| | - Viola Marconetto
- Data Science Department, EURECOM, Sophia Antipolis, France; Politecnico di Torino, Turin, Italy
| | - Prateek Mathur
- Data Science Department, EURECOM, Sophia Antipolis, France
| | - Karim Lekadir
- Artificial Intelligence in Medicine Lab, Facultat de Matemátiques I Informática, Universitat de Barcelona, Spain
| | - Marco Lorenzi
- Université Côte d'Azur, Inria Sophia Antipolis, Epione Research Group, Valbonne, France
| | - Ferran Prados
- Centre for Medical Image Computing, Department of Medical Physics and Bioengineering, University College London, UK; Queen Square MS Centre, Department of Neuroinflammation, UCL Queen Square Institute of Neurology, Faculty of Brain Sciences, University College London, UK; National Institute for Health Research, University College London Hospitals, Biomedical Research Centre, London, UK; e-health Center, Universitat Oberta de Catalunya, Barcelona, Spain
| | | |
Collapse
|
7
|
Kennedy BC, Katz J, Lepard J, Blount JP. Variation in pediatric stereoelectroencephalography practice among pediatric neurosurgeons in the United States: survey results. J Neurosurg Pediatr 2021; 28:212-220. [PMID: 34144513 DOI: 10.3171/2021.1.peds20799] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Accepted: 01/11/2021] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Stereoelectroencephalography (SEEG) has become widespread in the United States during the past decade. Many pediatric neurosurgeons practicing SEEG may not have had experience with this technique during their formal training, and the literature is mostly limited to single-center series. As a result, implementation of this relatively new technique may vary at different institutions. The authors hypothesized that aspects of SEEG experience, techniques, and outcomes would vary widely among programs across the country. METHODS An electronic survey with 35 questions addressing the categories of training and experience, technique, electrode locations, and outcomes was sent to 128 pediatric epilepsy surgeons who were potential SEEG users. RESULTS Sixty-one pediatric fellowship-trained epilepsy surgeons in the United States responded to the survey. Eighty-nine percent were actively using SEEG in their practice. Seventy-two percent of SEEG programs were in existence for less than 5 years, and 68% were using SEEG for > 70% of their invasive monitoring. Surgeons at higher-volume centers operated on younger patients (p < 0.001). Most surgeons (70%) spent 1-3 hours per case planning electrode trajectories. Two-thirds of respondents reported a median implant duration of 5-7 days, but 16% reported never having an implant duration > 5 days, and 16% reported having had implants stay in place for > 4 weeks. The median response for the median number of electrodes initially implanted was 12 electrodes, although 19% of respondents reported median implants of 5-8 electrodes and 17% reported median implants of 15-18 electrodes. Having a higher volume of SEEG cases per year was associated with a higher median number of electrodes implanted (p < 0.001). Most surgeons found SEEG helpful in defining an epileptic network and reported that most of their SEEG patients undergo focal surgical treatment. CONCLUSIONS SEEG has been embraced by the pediatric epilepsy surgery community. Higher case volume is correlated with a tendency to place more electrodes and operate on younger patients. For most parameters addressed in the survey, responses from surgeons clustered around a norm, though additional findings of substantial variations highlight differences in implementation and philosophy among pediatric epilepsy programs.
Collapse
Affiliation(s)
- Benjamin C Kennedy
- 1Division of Pediatric Neurosurgery, Department of Neurosurgery, Children's Hospital of Philadelphia
- 2Department of Neurosurgery, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Joshua Katz
- 3Rutgers-Robert Wood Johnson Medical School, New Brunswick, New Jersey; and
| | - Jacob Lepard
- 4Division of Pediatric Neurosurgery, Department of Neurosurgery, Children's of Alabama, University of Alabama at Birmingham, Alabama
| | - Jeffrey P Blount
- 4Division of Pediatric Neurosurgery, Department of Neurosurgery, Children's of Alabama, University of Alabama at Birmingham, Alabama
| |
Collapse
|
8
|
Patient-specific prediction of SEEG electrode bending for stereotactic neurosurgical planning. Int J Comput Assist Radiol Surg 2021; 16:789-798. [PMID: 33761063 PMCID: PMC8134306 DOI: 10.1007/s11548-021-02347-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Accepted: 03/05/2021] [Indexed: 12/01/2022]
Abstract
Purpose Electrode bending observed after stereotactic interventions is typically not accounted for in either computer-assisted planning algorithms, where straight trajectories are assumed, or in quality assessment, where only metrics related to entry and target points are reported. Our aim is to provide a fully automated and validated pipeline for the prediction of stereo-electroencephalography (SEEG) electrode bending. Methods We transform electrodes of 86 cases into a common space and compare features-based and image-based neural networks on their ability to regress local displacement (\documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\mathbf{lu} $$\end{document}lu) or electrode bending (\documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\hat{\mathbf{eb }}$$\end{document}eb^). Electrodes were stratified into six groups based on brain structures at the entry and target point. Models, both with and without Monte Carlo (MC) dropout, were trained and validated using tenfold cross-validation. Results mage-based models outperformed features-based models for all groups, and models that predicted \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\mathbf{lu} $$\end{document}lu performed better than for \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\hat{\mathbf{eb }}$$\end{document}eb^. Image-based model prediction with MC dropout resulted in lower mean squared error (MSE) with improvements up to 12.9% (\documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\mathbf{lu} $$\end{document}lu) and 39.9% (\documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\hat{\mathbf{eb }}$$\end{document}eb^), compared to no dropout. Using an image of brain tissue types (cortex, white and deep grey matter) resulted in similar, and sometimes better performance, compared to using a T1-weighted MRI when predicting \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\mathbf{lu} $$\end{document}lu. When inferring trajectories of image-based models (brain tissue types), 86.9% of trajectories had an MSE\documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\le 1$$\end{document}≤1 mm. Conclusion An image-based approach regressing local displacement with an image of brain tissue types resulted in more accurate electrode bending predictions compared to other approaches, inputs, and outputs. Future work will investigate the integration of electrode bending into planning and quality assessment algorithms. Supplementary Information The online version supplementary material available at 10.1007/s11548-021-02347-8.
Collapse
|
9
|
Damseh R, Delafontaine-Martel P, Pouliot P, Cheriet F, Lesage F. Laplacian Flow Dynamics on Geometric Graphs for Anatomical Modeling of Cerebrovascular Networks. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:381-394. [PMID: 32986549 DOI: 10.1109/tmi.2020.3027500] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Generating computational anatomical models of cerebrovascular networks is vital for improving clinical practice and understanding brain oxygen transport. This is achieved by extracting graph-based representations based on pre-mapping of vascular structures. Recent graphing methods can provide smooth vessels trajectories and well-connected vascular topology. However, they require water-tight surface meshes as inputs. Furthermore, adding vessels radii information on their graph compartments restricts their alignment along vascular centerlines. Here, we propose a novel graphing scheme that works with relaxed input requirements and intrinsically captures vessel radii information. The proposed approach is based on deforming geometric graphs constructed within vascular boundaries. Under a laplacian optimization framework, we assign affinity weights on the initial geometry that drives its iterative contraction toward vessels centerlines. We present a mechanism to decimate graph structure at each run and a convergence criterion to stop the process. A refinement technique is then introduced to obtain final vascular models. Our implementation is available on https://github.com/Damseh/VascularGraph. We benchmarked our results with that obtained using other efficient and state-of-the-art graphing schemes, validating on both synthetic and real angiograms acquired with different imaging modalities. The experiments indicate that the proposed scheme produces the lowest geometric and topological error rates on various angiograms. Furthermore, it surpasses other techniques in providing representative models that capture all anatomical aspects of vascular structures.
Collapse
|
10
|
Delgado-Martínez I, Serrano L, Higueras-Esteban A, Vivas E, Rocamora R, González Ballester MA, Serra L, Conesa G. On the Use of Digital Subtraction Angiography in Stereoelectroencephalography Surgical Planning to Prevent Collisions with Vessels. World Neurosurg 2020; 147:e47-e56. [PMID: 33249218 DOI: 10.1016/j.wneu.2020.11.103] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 11/17/2020] [Accepted: 11/18/2020] [Indexed: 01/29/2023]
Abstract
OBJECTIVE Stereoelectroencephalography (SEEG) consists of the implantation of microelectrodes for the electrophysiological characterization of epileptogenic networks. To reduce a possible risk of intracranial bleeding by vessel rupture during the electrode implantation, the stereotactic trajectories must follow avascular corridors. The use of digital subtraction angiography (DSA) for vascular visualization during planning is controversial due to the additional risk related to this procedure. Here we evaluate the utility of this technique for planning when the neurosurgeon has it available together with gadolinium-enhanced T1-weighted magnetic resonance sequence (T1-Gd) and computed tomography angiography (CTA). METHODS Twenty-two implantation plans for SEEG were initially done using T1-Gd imaging (251 trajectories). DSA was only used later during the revision process. In 6 patients CTA was available at this point as well. We quantified the position of the closest vessel to the trajectory in each of the imaging modalities. RESULTS Two thirds of the trajectories that appeared vessel free in the T1-Gd or CTA presented vessels in their proximity, as shown by DSA. Those modifications only required small shifts of both the entry and target point, so the diagnostic aims were preserved. CONCLUSIONS T1-Gd and CTA, despite being the most commonly used techniques for SEEG planning, frequently fail to reveal vessels that are dangerously close to the trajectories. Higher-resolution vascular imaging techniques, such as DSA, can provide the neurosurgeon with crucial information about vascular anatomy, resulting in safer plans.
Collapse
Affiliation(s)
- Ignacio Delgado-Martínez
- Epilepsy Research Group, Hospital del Mar Medical Research Institute, Barcelona, Spain; Galgo Medical, SL, Barcelona, Spain.
| | - Laura Serrano
- Epilepsy Research Group, Hospital del Mar Medical Research Institute, Barcelona, Spain
| | - Alfredo Higueras-Esteban
- Galgo Medical, SL, Barcelona, Spain; BCN Medtech, Department of Information and Communication Technologies, University Pompeu Fabra, Barcelona, Spain
| | - Elio Vivas
- Neuroangiography Therapeutic, Hospital del Mar, Barcelona, Spain
| | - Rodrigo Rocamora
- Epilepsy Research Group, Hospital del Mar Medical Research Institute, Barcelona, Spain
| | - Miguel A González Ballester
- BCN Medtech, Department of Information and Communication Technologies, University Pompeu Fabra, Barcelona, Spain; ICREA, Barcelona, Spain
| | | | - Gerardo Conesa
- Epilepsy Research Group, Hospital del Mar Medical Research Institute, Barcelona, Spain
| |
Collapse
|
11
|
Scorza D, El Hadji S, Cortés C, Bertelsen Á, Cardinale F, Baselli G, Essert C, Momi ED. Surgical planning assistance in keyhole and percutaneous surgery: A systematic review. Med Image Anal 2020; 67:101820. [PMID: 33075642 DOI: 10.1016/j.media.2020.101820] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Revised: 08/07/2020] [Accepted: 09/07/2020] [Indexed: 11/29/2022]
Abstract
Surgical planning of percutaneous interventions has a crucial role to guarantee the success of minimally invasive surgeries. In the last decades, many methods have been proposed to reduce clinician work load related to the planning phase and to augment the information used in the definition of the optimal trajectory. In this survey, we include 113 articles related to computer assisted planning (CAP) methods and validations obtained from a systematic search on three databases. First, a general formulation of the problem is presented, independently from the surgical field involved, and the key steps involved in the development of a CAP solution are detailed. Secondly, we categorized the articles based on the main surgical applications, which have been object of study and we categorize them based on the type of assistance provided to the end-user.
Collapse
Affiliation(s)
- Davide Scorza
- Vicomtech Foundation, Basque Research and Technology Alliance (BRTA), Donostia-San Sebastián, Spain; Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milan, Italy; Biodonostia Health Research Institute, Donostia-San Sebastián, Spain.
| | - Sara El Hadji
- Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milan, Italy.
| | - Camilo Cortés
- Vicomtech Foundation, Basque Research and Technology Alliance (BRTA), Donostia-San Sebastián, Spain; Biodonostia Health Research Institute, Donostia-San Sebastián, Spain
| | - Álvaro Bertelsen
- Vicomtech Foundation, Basque Research and Technology Alliance (BRTA), Donostia-San Sebastián, Spain; Biodonostia Health Research Institute, Donostia-San Sebastián, Spain
| | - Francesco Cardinale
- Claudio Munari Centre for Epilepsy and Parkinson surgery, Azienda Socio-Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda (ASST GOM Niguarda), Milan, Italy
| | - Giuseppe Baselli
- Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milan, Italy
| | - Caroline Essert
- ICube Laboratory, CNRS, UMR 7357, Université de Strasbourg, Strasbourg, France
| | - Elena De Momi
- Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milan, Italy
| |
Collapse
|
12
|
Detecting small conflicting drainages with contrast-enhanced magnetic resonance venography for surgical planning: a technical description and quantified analysis. Acta Neurochir (Wien) 2020; 162:2519-2526. [PMID: 32322998 DOI: 10.1007/s00701-020-04345-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Accepted: 04/09/2020] [Indexed: 10/24/2022]
Abstract
BACKGROUND Recent studies have shown the challenges involved in detecting small conflicting vessels (1.0-1.5 mm) on contrast-enhanced (CE) T1 images during stereoelectroencephalography (SEEG) planning. Improving the resolution of non-invasive approaches to identify these vessels is possible and important. We present a superior sagittal sinus mapping-based CE-magnetic resonance venography (CE-MRV) protocol calibrated by craniotomies. METHOD Seven patients with epileptic symptoms who received craniotomy were enrolled. CE-MRV was acquired with a bolus mapping of the superior sagittal sinus. Together with the T1 image, 3D veins and the brain surface were visualized. The resolution of the CE-MRV was quantified by measuring the diameter of superficial drainages after exposure of the brain surface during craniotomy. RESULTS A total of 37 superficial drainages were exposed in the bone windows. CE-MRV visualized all these drainages. On average, one superficial drainage could be found in every 13.2 mm diameter of the bone window. The boundary resolution of the CE-MRV was 0.58-0.8 mm in vessel diameter, while drainages larger than 0.8 mm were visualized consistently. CONCLUSIONS The resolution of the CE-MRV in the present study met the requirement for detection of small conflicting vessels during SEEG planning. The visualized venous landmarks could be used for visual guidance to the surgical zone. As a non-invasive approach, CE-MRV is practical to use in the clinical setting.
Collapse
|
13
|
De Barros A, Zaldivar-Jolissaint JF, Hoffmann D, Job-Chapron AS, Minotti L, Kahane P, De Schlichting E, Chabardès S. Indications, Techniques, and Outcomes of Robot-Assisted Insular Stereo-Electro-Encephalography: A Review. Front Neurol 2020; 11:1033. [PMID: 33041978 PMCID: PMC7527495 DOI: 10.3389/fneur.2020.01033] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Accepted: 08/07/2020] [Indexed: 01/04/2023] Open
Abstract
Stereo-electro-encephalography (SEEG) is an invasive, surgical, and electrophysiological method for three-dimensional registration and mapping of seizure activity in drug-resistant epilepsy. It allows the accurate analysis of spatio-temporal seizure activity by multiple intraparenchymal depth electrodes. The technique requires rigorous non-invasive pre-SEEG evaluation (clinical, video-EEG, and neuroimaging investigations) in order to plan the insertion of the SEEG electrodes with minimal risk and maximal recording accuracy. The resulting recordings are used to precisely define the surgical limits of resection of the epileptogenic zone in relation to adjacent eloquent structures. Since the initial description of the technique by Talairach and Bancaud in the 1950's, several techniques of electrode insertion have been used with accuracy and relatively few complications. In the last decade, robot-assisted surgery has emerged as a safe, accurate, and time-saving electrode insertion technique due to its unparalleled potential for orthogonal and oblique insertion trajectories, guided by rigorous computer-assisted planning. SEEG exploration of the insular cortex remains difficult due to its anatomical location, hidden by the temporal and frontoparietal opercula. Furthermore, the close vicinity of Sylvian vessels makes surgical electrode insertion challenging. Some epilepsy surgery teams remain cautious about insular exploration due to the potential of neurovascular injury. However, several authors have published encouraging results regarding the technique's accuracy and safety in both children and adults. We will review the indications, techniques, and outcomes of insular SEEG exploration with emphasis on robot-assisted implantation.
Collapse
Affiliation(s)
- Amaury De Barros
- Department of Neurosurgery, Toulouse University Hospital, Toulouse, France
| | | | - Dominique Hoffmann
- CHU Grenoble Alpes, Clinical University of Neurosurgery, Grenoble, France
| | | | - Lorella Minotti
- CHU Grenoble Alpes, Clinical University of Neurology, Grenoble, France
| | - Philippe Kahane
- CHU Grenoble Alpes, Clinical University of Neurology, Grenoble, France
| | | | - Stephan Chabardès
- CHU Grenoble Alpes, Clinical University of Neurosurgery, Grenoble, France
| |
Collapse
|
14
|
Knowledge-based automated planning system for StereoElectroEncephaloGraphy: A center-based scenario. J Biomed Inform 2020; 108:103460. [PMID: 32512210 DOI: 10.1016/j.jbi.2020.103460] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Revised: 05/24/2020] [Accepted: 05/28/2020] [Indexed: 11/22/2022]
Abstract
Surgical planning for StereoElectroEncephaloGraphy (SEEG) is a complex and patient specific task, where the experience and medical workflow of each institution may influence the final planning choices. To account for this variability, we developed a data-based Computer Assisted Planning (CAP) solution able to exploit the knowledge extracted by past cases. By the analysis of retrospective patients' data sets, our system proposes a pool of trajectories commonly used by the institution, which can be selected to initialize a new patient plan. An optimization framework adapts those to the patient's anatomy by optimizing clinical requirements (e.g. distance from vessel, gray matter recording and insertion angle), and adapting its strategy based on the trajectory type selected.The system has been customized based on the data of a single institution. Two neurosurgeons, working in a high-volume hospital, have validated it by using 15 retrospective patient data sets, with more than 200 trajectories reviewed. Both surgeons considered ~81% of the optimized trajectories as clinically feasible (75% inter-rater reliability). Quantitative comparison of distance from vessels, insertion angle and gray matter recording index showed that the optimized trajectories reached superior or comparable values with respect to the original manual plans. The results suggest that a tailored center-based solution could increase the acceptance rate of the automated trajectories proposed.
Collapse
|
15
|
|
16
|
Abstract
The intracranial electroencephalogram (iEEG) is essential in decision making for epilepsy surgery. Although localization of epileptogenic brain regions by means of iEEG has been the gold standard for surgical decision-making for more than 70 years, established guidelines for what constitutes genuine iEEG epileptic activity and what is normal brain activity are not available. This review provides a summary of the current state of knowledge and understanding on normal iEEG entities and variants, the effects of sleep on regional and lobar iEEG, iEEG patterns of interictal and ictal epileptic activity and their relation to well-described epileptogenic pathologies and surgical outcome.
Collapse
|
17
|
Dorfer C, Rydenhag B, Baltuch G, Buch V, Blount J, Bollo R, Gerrard J, Nilsson D, Roessler K, Rutka J, Sharan A, Spencer D, Cukiert A. How technology is driving the landscape of epilepsy surgery. Epilepsia 2020; 61:841-855. [PMID: 32227349 PMCID: PMC7317716 DOI: 10.1111/epi.16489] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Revised: 03/03/2020] [Accepted: 03/04/2020] [Indexed: 12/24/2022]
Abstract
This article emphasizes the role of the technological progress in changing the landscape of epilepsy surgery and provides a critical appraisal of robotic applications, laser interstitial thermal therapy, intraoperative imaging, wireless recording, new neuromodulation techniques, and high-intensity focused ultrasound. Specifically, (a) it relativizes the current hype in using robots for stereo-electroencephalography (SEEG) to increase the accuracy of depth electrode placement and save operating time; (b) discusses the drawback of laser interstitial thermal therapy (LITT) when it comes to the need for adequate histopathologic specimen and the fact that the concept of stereotactic disconnection is not new; (c) addresses the ratio between the benefits and expenditure of using intraoperative magnetic resonance imaging (MRI), that is, the high technical and personnel expertise needed that might restrict its use to centers with a high case load, including those unrelated to epilepsy; (d) soberly reviews the advantages, disadvantages, and future potentials of neuromodulation techniques with special emphasis on the differences between closed and open-loop systems; and (e) provides a critical outlook on the clinical implications of focused ultrasound, wireless recording, and multipurpose electrodes that are already on the horizon. This outlook shows that although current ultrasonic systems do have some limitations in delivering the acoustic energy, further advance of this technique may lead to novel treatment paradigms. Furthermore, it highlights that new data streams from multipurpose electrodes and wireless transmission of intracranial recordings will become available soon once some critical developments will be achieved such as electrode fidelity, data processing and storage, heat conduction as well as rechargeable technology. A better understanding of modern epilepsy surgery will help to demystify epilepsy surgery for the patients and the treating physicians and thereby reduce the surgical treatment gap.
Collapse
Affiliation(s)
- Christian Dorfer
- Department of NeurosurgeryMedical University of ViennaViennaAustria
| | - Bertil Rydenhag
- Department of Clinical NeuroscienceInstitute of Neuroscience and PhysiologyThe Sahlgrenska AcademyUniversity of GothenburgGothenburgSweden
- Department of NeurosurgerySahlgrenska University HospitalGothenburgSweden
| | - Gordon Baltuch
- Center for Functional and Restorative NeurosurgeryUniversity of PennsylvaniaPhiladelphiaPAUSA
| | - Vivek Buch
- Center for Functional and Restorative NeurosurgeryUniversity of PennsylvaniaPhiladelphiaPAUSA
| | - Jeffrey Blount
- Division of NeurosurgeryUniversity of Alabama at Birmingham School of MedicineBirminghamALUSA
| | - Robert Bollo
- Department of NeurosurgeryUniversity of Utah School of MedicineSalt Lake CityUTUSA
| | - Jason Gerrard
- Department of NeurosurgeryYale University School of MedicineNew HavenCTUSA
| | - Daniel Nilsson
- Department of Clinical NeuroscienceInstitute of Neuroscience and PhysiologyThe Sahlgrenska AcademyUniversity of GothenburgGothenburgSweden
- Department of NeurosurgerySahlgrenska University HospitalGothenburgSweden
| | - Karl Roessler
- Department of NeurosurgeryMedical University of ViennaViennaAustria
- Department of NeurosurgeryUniversity of ErlangenErlangenGermany
| | - James Rutka
- Division of Pediatric NeurosurgeryThe Hospital for Sick ChildrenUniversity of TorontoTorontoOntarioCanada
| | - Ashwini Sharan
- Department of Neurosurgery and NeurologyThomas Jefferson UniversityPhiladelphiaPAUSA
| | - Dennis Spencer
- Department of NeurosurgeryYale University School of MedicineNew HavenCTUSA
| | - Arthur Cukiert
- Neurology and Neurosurgery Clinic Sao PauloClinica Neurologica CukiertSao PauloBrazil
| |
Collapse
|
18
|
Cardinale F. Commentary: Incorporating New Technology Into a Surgical Technique: The Learning Curve of a Single Surgeon's Stereo-Electroencephalography Experience. Neurosurgery 2020; 86:E290-E291. [DOI: 10.1093/neuros/nyz569] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Accepted: 12/07/2019] [Indexed: 11/14/2022] Open
Affiliation(s)
- Francesco Cardinale
- “Claudio Munari” Centre for Epilepsy Surgery, Niguarda Hospital, Milano, Italia
| |
Collapse
|
19
|
Kim LH, Feng AY, Ho AL, Parker JJ, Kumar KK, Chen KS, Grant GA, Henderson JM, Halpern CH. Robot-assisted versus manual navigated stereoelectroencephalography in adult medically-refractory epilepsy patients. Epilepsy Res 2019; 159:106253. [PMID: 31855826 DOI: 10.1016/j.eplepsyres.2019.106253] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2019] [Revised: 10/14/2019] [Accepted: 12/07/2019] [Indexed: 10/25/2022]
Abstract
OBJECTIVE Stereoelectroencephalography (SEEG) has experienced a recent growth in adoption for epileptogenic zone (EZ) localization. Advances in robotics have the potential to improve the efficiency and safety of this intracranial seizure monitoring method. We present our institutional experience employing robot-assisted SEEG and compare its operative efficiency, seizure reduction outcomes, and direct hospital costs with SEEG performed without robotic assistance using navigated stereotaxy. METHODS We retrospectively identified 50 consecutive adult SEEG cases at our institution in this IRB-approved study, of which 25 were navigated with image guidance (hereafter referred to as "navigated") (02/2014-10/2016) and 25 were robot-assisted (09/2016-12/2017). A thorough review of medical/surgical history and operative records with imaging and trajectory plans was done for each patient. Direct inpatient costs related to each technique were compared. RESULTS Most common seizure etiologies for patients undergoing navigated and robot-assisted SEEG included non-lesional and benign temporal lesions. Despite having a higher mean number of leads-per-patient (10.2 ± 3.5 versus 7.2 ± 2.6, P = 0.002), robot-assisted cases had a significantly shorter mean operative time than navigated cases (125.5±48.5 versus 173.4±84.3 min, P = 0.02). Comparison of robot-assisted cases over the study interval revealed no significant difference in mean operative time (136.4±51.4 min for the first ten cases versus 109.9±75.8 min for the last ten cases, P = 0.25) and estimated operative time-per-lead (13.4±6.0 min for the first ten cases versus 12.9±7.7 min for the last ten cases, P = 0.86). The mean depth, radial, target, and entry point errors for robot-assisted cases were 2.12±1.89, 1.66±1.58, 3.05±2.02 mm, and 1.39 ± 0.75 mm, respectively. The two techniques resulted in equivalent EZ localization rate (navigated 88 %, robot-assisted 96 %, P = 0.30). Common types of epilepsy surgery performed consisted of implantation of responsive neurostimulation (RNS) device (56 %), resection (19.1 %), and laser ablation (23.8 %) for navigated SEEG. For robot-assisted SEEG, either RNS implantation (68.2 %) or laser ablation (22.7 %) were performed or offered. A majority of navigated and robot-assisted patients who underwent epilepsy surgery achieved either Engel Class I (navigated 36.8 %, robot-assisted 31.6 %) or II (navigated 36.8 %, robot-assisted 15.8 %) outcome with no significant difference between the groups (P = 0.14). Direct hospital cost for robot-assisted SEEG was 10 % higher than non-robotic cases. CONCLUSION This single-institutional study suggests that robotic assistance can enhance efficiency of SEEG without compromising safety or precision when compared to image guidance only. Adoption of this technique with uniform safety and efficacy over a short period of time is feasible with favorable epilepsy outcomes.
Collapse
Affiliation(s)
- Lily H Kim
- Department of Neurosurgery, Stanford University School of Medicine, United States
| | - Austin Y Feng
- Department of Neurosurgery, Stanford University School of Medicine, United States
| | - Allen L Ho
- Department of Neurosurgery, Stanford University School of Medicine, United States
| | - Jonathon J Parker
- Department of Neurosurgery, Stanford University School of Medicine, United States
| | - Kevin K Kumar
- Department of Neurosurgery, Stanford University School of Medicine, United States
| | - Kevin S Chen
- Department of Neurosurgery, Stanford University School of Medicine, United States
| | - Gerald A Grant
- Department of Neurosurgery, Stanford University School of Medicine, United States; Division of Pediatric Neurosurgery, Lucile Packard Children's Hospital Stanford, United States
| | - Jaimie M Henderson
- Department of Neurosurgery, Stanford University School of Medicine, United States
| | - Casey H Halpern
- Division of Pediatric Neurosurgery, Lucile Packard Children's Hospital Stanford, United States.
| |
Collapse
|
20
|
Li K, Vakharia VN, Sparks R, Rodionov R, Vos SB, McEvoy AW, Miserocchi A, Wang M, Ourselin S, Duncan JS. Stereoelectroencephalography electrode placement: Detection of blood vessel conflicts. Epilepsia 2019; 60:1942-1948. [PMID: 31329275 PMCID: PMC6851756 DOI: 10.1111/epi.16294] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2018] [Revised: 06/27/2019] [Accepted: 06/28/2019] [Indexed: 11/30/2022]
Abstract
OBJECTIVE Various forms of vascular imaging are performed to identify vessels that should be avoided during stereoelectroencephalography (SEEG) planning. Digital subtraction angiography (DSA) is the gold standard for intracranial vascular imaging. DSA is an invasive investigation, and a balance is necessary to identify all clinically relevant vessels and not to visualize irrelevant vessels that may unnecessarily restrict electrode placement. We sought to estimate the size of vessels that are clinically significant for SEEG planning. METHODS Thirty-three consecutive patients who underwent 354 SEEG electrode implantations planned with computer-assisted planning and DSA segmentation between 2016 and 2018 were identified from a prospectively maintained database. Intracranial positions of electrodes were segmented from postimplantation computed tomography scans. Each electrode was manually reviewed using "probe-eye view" with the raw preoperative DSA images for vascular conflicts. The diameter of vessels and the location of conflicts were noted. Vessel conflicts identified on raw DSA images were cross-referenced against other modalities to determine whether the conflict could have been detected. RESULTS One hundred sixty-six vessel conflicts were identified between electrodes and DSA-identified vessels, with 0-3 conflicts per electrode and a median of four conflicts per patient. The median diameter of conflicting vessels was 1.3 mm (interquartile range [IQR] = 1.0-1.5 mm). The median depth of conflict was 31.0 mm (IQR = 14.3-45.0 mm) from the cortical surface. The addition of sulcal models to DSA, magnetic resonance venography (MRV), and T1 + gadolinium images, as an exclusion zone during computer-assisted planning, would have prevented the majority of vessel conflicts. We were unable to determine whether vessels were displaced or transected by the electrodes. SIGNIFICANCE Vascular segmentation from DSA images was significantly more sensitive than T1 + gadolinium or MRV images. Electrode conflicts with vessels 1-1.5 mm in size did not result in a radiologically detectable or clinically significant hemorrhage and could potentially be excluded from consideration during SEEG planning.
Collapse
Affiliation(s)
- Kuo Li
- Department of NeurosurgeryThe First Affiliated Hospital of Xi'an Jiaotong UniversityXi'anChina
- Department of Clinical and Experimental EpilepsyUniversity College LondonLondonUK
- National Hospital for Neurology and Neurosurgery, Queen SquareLondonUK
- Chalfont Centre for EpilepsyChalfontUK
| | - Vejay N. Vakharia
- Department of Clinical and Experimental EpilepsyUniversity College LondonLondonUK
- National Hospital for Neurology and Neurosurgery, Queen SquareLondonUK
- Chalfont Centre for EpilepsyChalfontUK
| | - Rachel Sparks
- School of Biomedical Engineering and Imaging SciencesSt Thomas’ HospitalKing's College LondonLondonUK
| | - Roman Rodionov
- Department of Clinical and Experimental EpilepsyUniversity College LondonLondonUK
- National Hospital for Neurology and Neurosurgery, Queen SquareLondonUK
- Chalfont Centre for EpilepsyChalfontUK
| | - Sjoerd B. Vos
- Department of Clinical and Experimental EpilepsyUniversity College LondonLondonUK
- Centre for Medical Image ComputingUniversity College LondonLondonUK
| | - Andrew W. McEvoy
- National Hospital for Neurology and Neurosurgery, Queen SquareLondonUK
| | - Anna Miserocchi
- National Hospital for Neurology and Neurosurgery, Queen SquareLondonUK
| | - Maode Wang
- Department of NeurosurgeryThe First Affiliated Hospital of Xi'an Jiaotong UniversityXi'anChina
| | - Sebastien Ourselin
- School of Biomedical Engineering and Imaging SciencesSt Thomas’ HospitalKing's College LondonLondonUK
| | - John S. Duncan
- Department of Clinical and Experimental EpilepsyUniversity College LondonLondonUK
- National Hospital for Neurology and Neurosurgery, Queen SquareLondonUK
- Chalfont Centre for EpilepsyChalfontUK
| |
Collapse
|