1
|
Feng Y, Feng Y, Fan Y, Ge J. Effects of table based air curtains on respiratory aerosol exposure risk mitigation at face-to-face meeting setups. JOURNAL OF HAZARDOUS MATERIALS 2024; 477:135373. [PMID: 39111174 DOI: 10.1016/j.jhazmat.2024.135373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Revised: 07/26/2024] [Accepted: 07/27/2024] [Indexed: 08/17/2024]
Abstract
Face-to-face meetings on a conference table are a frequent form of communication. The short-range exposure risk of aerosol disease transmission is high in the scenario of susceptible facing the infectious person over the table. We propose a mitigation methodology using the air curtain to reduce direct exposure to virus-laden aerosols. A numerical model was validated with experimental data to simulate the dispersion of aerosols. A dynamic mesh was adopted to consider the head movement of a 3D thermal manikin model. Results show that nodding head increase the potential risk by 74 % compared to motionless. Subsequently, for a single air curtain, placing it in the middle of the table is more effective in preventing risks than on the sides. For double air curtains, increasing the distance between them has a greater risk reduction effect than a shorter distance. Increasing the air velocity or width is more effective than increasing the number of air curtains. A moderate velocity (1 m s-1) works well to reduce the risk of nasal breathing. A higher velocity (2 m s-1) is needed for the coughing scenario. For similar indoor environments, the air curtains on the table can offer active precautions without changing the current ventilation system.
Collapse
Affiliation(s)
- Yinshuai Feng
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, China; International Research Center for Green Building and Low-Carbon City, International Campus, Zhejiang University, Haining, China
| | - Yu Feng
- School of Chemical Engineering, Oklahoma State University, Stillwater, OK, USA
| | - Yifan Fan
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, China; International Research Center for Green Building and Low-Carbon City, International Campus, Zhejiang University, Haining, China.
| | - Jian Ge
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, China; International Research Center for Green Building and Low-Carbon City, International Campus, Zhejiang University, Haining, China
| |
Collapse
|
2
|
Zhu J, Hu Q, He X, Wang L, Xu H, Benjamin Oduro N. 8-hour performance of loose-fitting powered air-purifying respirators in simulated hospital and coal mine environments. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2023; 20:598-609. [PMID: 37682703 DOI: 10.1080/15459624.2023.2256809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/10/2023]
Abstract
Loose-fitting powered air-purifying respirators (LF-PAPRs) are increasingly used in hospitals and coal mines because of their high comfort and protection level, but the utilization faces the challenges of 8-hr continuous high protection requirements in the hospital environment and the coupling effects of high temperature, high humidity, high dust concentration in coal mines. Based on the self-developed powered air-purifying respirator simulation test system, this study explores the 8-hr changes of supplied airflow, the relative air pressure inside the inlet covering (ΔP), and total inward leakage (TIL) of four models of LF-PAPRs in simulated hospital and coal mine environments. Results show that: (1) In a simulated hospital environment, all four LF-PAPRs showed filter cartridge blockage within 5 ∼ 6 hr of continuous operation; while in the simulated coal mine, three models of LF-PAPRs showed filter cartridge blockage within 3 hr. (2) In both the hospital and coal mine environments, there are cases where the supplied airflow of LF-PAPRs dropped below 170 L/min within 3 hr. (3) In a simulated hospital environment, the ΔP of all LF-PAPRs maintained positive within 5-6 hr; while in the simulated coal mine, the ΔP of two LF-PAPRs, respectively, appeared negative after 1 hr and 1.6 hr operation. (4) The maximum TIL of the tested LF-PAPRs, respectively ranged from 0.5-0.9% and 1.4-3% in simulated hospital and coal mine environments. (5) In both hospital and coal mine environments, the supplied airflow and ΔP of each LF-PAPR showed a decreasing trend with increasing test duration, while the TIL significantly increased with testing time. (6) The supplied airflow, ΔP, and TIL of each LF-PAPR in the simulated hospital environment performed better than those in the coal mine. This study evaluated the performance of PAPR under the most severe operating conditions, and respirator performance may differ under in-situ conditions.
Collapse
Affiliation(s)
- Jintuo Zhu
- Key Laboratory of Coal Methane and Fire Control, Ministry of Education, China University of Mining and Technology, Xuzhou, Jiangsu, China
- National Professional Laboratory for Fundamental Research of Mine Gas and Dust Control Technology, School of Safety Engineering, China University of Mining and Technology, Xuzhou, Jiangsu, China
- School of Safety Engineering, China University of Mining and Technology, Xuzhou, Jiangsu, China
| | - Qi Hu
- Key Laboratory of Coal Methane and Fire Control, Ministry of Education, China University of Mining and Technology, Xuzhou, Jiangsu, China
- National Professional Laboratory for Fundamental Research of Mine Gas and Dust Control Technology, School of Safety Engineering, China University of Mining and Technology, Xuzhou, Jiangsu, China
- School of Safety Engineering, China University of Mining and Technology, Xuzhou, Jiangsu, China
| | - Xinjian He
- Key Laboratory of Coal Methane and Fire Control, Ministry of Education, China University of Mining and Technology, Xuzhou, Jiangsu, China
- National Professional Laboratory for Fundamental Research of Mine Gas and Dust Control Technology, School of Safety Engineering, China University of Mining and Technology, Xuzhou, Jiangsu, China
- School of Safety Engineering, China University of Mining and Technology, Xuzhou, Jiangsu, China
| | - Liang Wang
- Key Laboratory of Coal Methane and Fire Control, Ministry of Education, China University of Mining and Technology, Xuzhou, Jiangsu, China
- National Professional Laboratory for Fundamental Research of Mine Gas and Dust Control Technology, School of Safety Engineering, China University of Mining and Technology, Xuzhou, Jiangsu, China
- School of Safety Engineering, China University of Mining and Technology, Xuzhou, Jiangsu, China
| | - Huan Xu
- School of Materials Science and Physics, China University of Mining and Technology, Xuzhou, Jiangsu, China
| | - Nkansah Benjamin Oduro
- Key Laboratory of Coal Methane and Fire Control, Ministry of Education, China University of Mining and Technology, Xuzhou, Jiangsu, China
- National Professional Laboratory for Fundamental Research of Mine Gas and Dust Control Technology, School of Safety Engineering, China University of Mining and Technology, Xuzhou, Jiangsu, China
- School of Safety Engineering, China University of Mining and Technology, Xuzhou, Jiangsu, China
| |
Collapse
|
3
|
Yang S, Muthalagu A, Serrano VG, Licina D. Human personal air pollution clouds in a naturally ventilated office during the COVID-19 pandemic. BUILDING AND ENVIRONMENT 2023; 236:110280. [PMID: 37064616 PMCID: PMC10080864 DOI: 10.1016/j.buildenv.2023.110280] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 03/31/2023] [Accepted: 04/05/2023] [Indexed: 05/03/2023]
Abstract
Personal cloud, termed as the difference in air pollutant concentrations between breathing zone and room sites, represents the bias in approximating personal inhalation exposure that is linked to accuracy of health risk assessment. This study performed a two-week field experiment in a naturally ventilated office during the COVID-19 pandemic to assess occupants' exposure to common air pollutants and to determine factors contributing to the personal cloud effect. During occupied periods, indoor average concentrations of endotoxin (0.09 EU/m3), TVOC (231 μg/m3), CO2 (630 ppm), and PM10 (14 μg/m3) were below the recommended limits, except for formaldehyde (58 μg/m3). Personal exposure concentrations, however, were significantly different from, and mostly higher than, concentrations measured at room stationary sampling sites. Although three participants shared the same office, their personal air pollution clouds were mutually distinct. The mean personal cloud magnitude ranged within 0-0.05 EU/m3, 35-192 μg/m3, 32-120 ppm, and 4-9 μg/m3 for endotoxin, TVOC, CO2, and PM10, respectively, and was independent from room concentrations. The use of hand sanitizer was strongly associated with an elevated personal cloud of endotoxin and alcohol-based VOCs. Reduced occupancy density in the office resulted in more pronounced personal CO2 clouds. The representativeness of room stationary sampling for capturing dynamic personal exposures was as low as 28% and 5% for CO2 and PM10, respectively. The findings of our study highlight the necessity of considering the personal cloud effect when assessing personal exposure in offices.
Collapse
Affiliation(s)
- Shen Yang
- Human-Oriented Built Environment Lab, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Akila Muthalagu
- Human-Oriented Built Environment Lab, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
- Environmental Systems Group, Department of Civil Engineering, Indian Institute of Technology Hyderabad, Kandi, India
| | - Viviana González Serrano
- Human-Oriented Built Environment Lab, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Dusan Licina
- Human-Oriented Built Environment Lab, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| |
Collapse
|
4
|
Murga A, Bale R, Li CG, Ito K, Tsubokura M. Large eddy simulation of droplet transport and deposition in the human respiratory tract to evaluate inhalation risk. PLoS Comput Biol 2023; 19:e1010972. [PMID: 36940207 PMCID: PMC10027217 DOI: 10.1371/journal.pcbi.1010972] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Accepted: 02/22/2023] [Indexed: 03/21/2023] Open
Abstract
As evidenced by the worldwide pandemic, respiratory infectious diseases and their airborne transmission must be studied to safeguard public health. This study focuses on the emission and transport of speech-generated droplets, which can pose risk of infection depending on the loudness of the speech, its duration and the initial angle of exhalation. We have numerically investigated the transport of these droplets into the human respiratory tract by way of a natural breathing cycle in order to predict the infection probability of three strains of SARS-CoV-2 on a person who is listening at a one-meter distance. Numerical methods were used to set the boundary conditions of the speaking and breathing models and large eddy simulation (LES) was used for the unsteady simulation of approximately 10 breathing cycles. Four different mouth angles when speaking were contrasted to evaluate real conditions of human communication and the possibility of infection. Breathed virions were counted using two different approaches: the breathing zone of influence and direction deposition on the tissue. Our results show that infection probability drastically changes based on the mouth angle and the breathing zone of influence overpredicts the inhalation risk in all cases. We conclude that to portray real conditions, the probability of infection should be based on direct tissue deposition results to avoid overprediction and that several mouth angles must be considered in future analyses.
Collapse
Affiliation(s)
- Alicia Murga
- Kobe University, Graduate School of System Informatics, Japan
| | - Rahul Bale
- Kobe University, Graduate School of System Informatics, Japan
- Riken Center for Computational Sciences, Japan
| | | | - Kazuhide Ito
- Kyushu University, Faculty of Engineering Sciences, Japan
| | - Makoto Tsubokura
- Kobe University, Graduate School of System Informatics, Japan
- Riken Center for Computational Sciences, Japan
| |
Collapse
|
5
|
Yoo SJ, Kurokawa A, Matsunaga K, Ito K. Spatial distributions of airborne transmission risk on commuter buses: Numerical case study using computational fluid and particle dynamics with computer-simulated persons. EXPERIMENTAL AND COMPUTATIONAL MULTIPHASE FLOW 2023; 5:304-318. [PMID: 36788805 PMCID: PMC9912221 DOI: 10.1007/s42757-022-0146-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 06/27/2022] [Accepted: 09/07/2022] [Indexed: 02/12/2023]
Abstract
Commuter buses have a high passenger density relative to the interior cabin volume, and it is difficult to maintain a physical/social distance in terms of airborne transmission control. Therefore, it is important to quantitatively investigate the impact of ventilation and air-conditioning in the cabin on the airborne transmission risk for passengers. In this study, comprehensive coupled numerical simulations using computational fluid and particle dynamics (CFPD) and computer-simulated persons (CSPs) were performed to investigate the heterogeneous spatial distribution of the airborne transmission risk in a commuter bus environment under two types of layouts of the ventilation system and two types of passenger densities. Through a series of particle transmission analysis and infection risk assessment in this study, it was revealed that the layout of the supply inlet/exhaust outlet openings of a heating, ventilation, and air-conditioning (HVAC) system has a significant impact on the particle dispersion characteristics inside the bus cabin, and higher infection risks were observed near the single exhaust outlet in the case of higher passenger density. The integrated analysis of CFPD and CSPs in a commuter bus cabin revealed that the airborne transmission risk formed significant heterogeneous spatial distributions, and the changes in air-conditioning conditions had a certain impact on the risk.
Collapse
Affiliation(s)
- Sung-Jun Yoo
- Faculty of Engineering Sciences, Kyushu University, 6-1 Kasuga-koen, Kasuga, Fukuoka, 816-8580 Japan
| | - Akira Kurokawa
- Interdisciplinary Graduate School of Engineering Science, Kyushu University, 6-1 Kasuga-koen, Kasuga, Fukuoka, 816-8580 Japan
| | - Kazuhiko Matsunaga
- Kanagawa Prefectural Junior College for Industrial Technology, 2-4-1 Nakao, Asahi-ku, Yokohama, Kanagawa, 241-0815 Japan
| | - Kazuhide Ito
- Faculty of Engineering Sciences, Kyushu University, 6-1 Kasuga-koen, Kasuga, Fukuoka, 816-8580 Japan
| |
Collapse
|
6
|
Wang C, Su ZH, He MJ. Dynamic variation and inhalation exposure of organophosphates esters and phthalic acid esters in face masks. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2023; 316:120703. [PMID: 36403876 PMCID: PMC9671703 DOI: 10.1016/j.envpol.2022.120703] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 11/02/2022] [Accepted: 11/17/2022] [Indexed: 06/16/2023]
Abstract
The coronavirus pandemic (COVID-19) has posed a huge global health threat since December 2019. Wearing face masks is known as an effective measure for controlling the wide spread of COVID-19 and its variants. But on the other hand, face masks could be a potential source of organophosphate esters (OPEs) and phthalic acid esters (PAEs) as they are extensively added in masks. However, knowledge associated with the occurrence as well as inhalation risks of OPEs and PAEs in masks is limited. In this study, OPEs and PAEs were determined in different types of mask samples collected from the local market. OPEs and PAEs were detected in mask samples ranging from 36.7 to 855 ng/g, and from 251 to 3830 ng/g, respectively. Relatively lower OPEs and PAEs concentrations were observed in disposable mask for toddlers. Simulated inhalation experiment indicated that the mass loss of OPEs and PAEs was 136 and 3910 ng/mask in disposable masks, 71.9 and 763 ng/mask in disposable mask for toddlers, 924 and 1020 ng/mask in N95 mask after 12 h, respectively. Significantly negative correlations were exhibited between the decrement of OPEs in masks and the increment of OPEs in corresponding polyurethane foams (PUFs) during the course, elucidating OPEs released from masks could be well captured by PUFs. With regard to the variation over time, predominant OPE and PAE analogues showed semblable release and absorption tendency in mask and corresponding PUF. Inhalation exposure risk of OPEs and PAEs was estimated based on the increment of pollutants in PUF. The estimated daily intakes (EDIs), hazard index (HI) and carcinogenic risk (CR) were also calculated and they were within the threshold levels. This study provides the evidence of OPEs and PAEs releasing from the face masks during wearing and unveiled a potential source of OPEs and PAEs exposure to humans.
Collapse
Affiliation(s)
- Can Wang
- College of Resources and Environment, Southwest University, Chongqing, 400716, China
| | - Zi-Han Su
- College of Resources and Environment, Southwest University, Chongqing, 400716, China
| | - Ming-Jing He
- College of Resources and Environment, Southwest University, Chongqing, 400716, China; Chongqing Key Laboratory of Agricultural Resources and Environment, Chongqing, 400716, China.
| |
Collapse
|
7
|
Kuga K, Sakamoto M, Wargocki P, Ito K. Prediction of exhaled carbon dioxide concentration using a computer-simulated person that included alveolar gas exchange. INDOOR AIR 2022; 32:e13079. [PMID: 36040273 DOI: 10.1111/ina.13079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 06/06/2022] [Accepted: 07/03/2022] [Indexed: 06/15/2023]
Abstract
Accurate prediction of inhaled CO2 concentration and alveolar gas exchange efficiency would improve the prediction of CO2 concentrations around the human body, which is essential for advanced ventilation design in buildings. We therefore, developed a computer-simulated person (CSP) that included a computational fluid dynamics approach. The CSP simulates metabolic heat production at the skin surface and carbon dioxide (CO2 ) gas exchange at the alveoli during the transient breathing cycle. This makes it possible to predict the CO2 distribution around the human body. The numerical model of the CO2 gas exchange mechanism includes both the upper and lower airways and makes it possible to calculate the alveolar CO2 partial pressure; this improves the prediction accuracy. We used the CSP to predict emission rates of metabolically generated CO2 exhaled by a person and assumed that the tidal volume will be unconsciously reduced as a result of exposure to poor indoor air quality. A reduction in tidal volume resulted in a decrease in CO2 emission rates of the same magnitude as was observed in our published experimental data. We also observed that the predicted inhaled CO2 concentration depended on the flow pattern around the human body, as would be expected.
Collapse
Affiliation(s)
- Kazuki Kuga
- Faculty of Engineering Sciences, Kyushu University, Kasuga, Japan
| | - Mitsuharu Sakamoto
- Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Kasuga-shi, Japan
| | - Pawel Wargocki
- International Centre for Indoor Environment and Energy, Department of Environmental and Resources Engineering, Technical University of Denmark, Kongens Lyngby, Denmark
| | - Kazuhide Ito
- Faculty of Engineering Sciences, Kyushu University, Kasuga, Japan
| |
Collapse
|