1
|
Brown TR, Edrington TS, Genovese KJ, He HL, Anderson RC, Nisbet DJ. Evaluation of the Efficacy of Three Direct Fed Microbial Cocktails To Reduce Fecal Shedding of Escherichia coli O157:H7 in Naturally Colonized Cattle and Fecal Shedding and Peripheral Lymph Node Carriage of Salmonella in Experimentally Infected Cattle. J Food Prot 2020; 83:28-36. [PMID: 31809195 DOI: 10.4315/0362-028x.jfp-19-208] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Two experiments were conducted to evaluate the feeding of direct fed microbials (DFMs) on fecal shedding of Escherichia coli O157:H7 in naturally infected cattle (experiment I) and on Salmonella in the feces and peripheral lymph nodes (PLNs) of experimentally infected cattle (experiment II). Thirty cattle, 10 per treatment, were used in each experiment. Treatments in experiment I consisted of a control (lactose carrier only); DFM1, a 1:1 ratio of Enterococcus faecium and Lactobacillus animalis; and DFM2, a 1:1 ratio of Lactobacillus acidophilus and Pediococcus acidilactici. In Experiment II, DFM1 was replaced with DFM3, a 1:2 ratio of Lactobacillus reuteri and other Lactobacillus strains. Additives were mixed in water and applied as a top-dressing to each pen's daily ration for 50 days. Approximately half-way through each experiment, the DFM concentration was doubled for the remainder of the study. Fecal samples were collected throughout experiment I and cultured for E. coli O157:H7. Cattle in experiment II were inoculated intradermally with Salmonella Montevideo on days 32, 37, and 42 and then necropsied on days 49 and 50 (five cattle per treatment on each day). Innate immune function was assessed on days 29, 49, and 50. In experiment I, fecal concentration and prevalence of E. coli O157:H7 were not different (P > 0.10) nor was there an effect (P = 0.95) on the percentage of super shedders (cattle shedding ≥3.0 log CFU/g of feces). In experiment II, no treatment differences (P > 0.05) were observed for Salmonella in the PLNs except for the inguinal nodes, which had a significantly lower Salmonella prevalence in DFM-supplemented cattle than in the controls. Immune function, as measured by monocyte nitric oxide production and neutrophil oxidative burst, was decreased (P < 0.05) in the DFM treatment groups. Although results of this research indicate little to no effect of these DFMs on E. coli O157:H7 or Salmonella in cattle, an increase in the duration of administration to that similar to what is used for commercial cattle might elicit treatment differences.
Collapse
Affiliation(s)
- T R Brown
- U.S. Department of Agriculture, Agricultural Research Service, Food and Feed Safety Research Unit, 2881 F&B Road, College Station, Texas 77845, USA
| | - T S Edrington
- U.S. Department of Agriculture, Agricultural Research Service, Food and Feed Safety Research Unit, 2881 F&B Road, College Station, Texas 77845, USA
| | - K J Genovese
- U.S. Department of Agriculture, Agricultural Research Service, Food and Feed Safety Research Unit, 2881 F&B Road, College Station, Texas 77845, USA
| | - H L He
- U.S. Department of Agriculture, Agricultural Research Service, Food and Feed Safety Research Unit, 2881 F&B Road, College Station, Texas 77845, USA
| | - R C Anderson
- U.S. Department of Agriculture, Agricultural Research Service, Food and Feed Safety Research Unit, 2881 F&B Road, College Station, Texas 77845, USA
| | - D J Nisbet
- U.S. Department of Agriculture, Agricultural Research Service, Food and Feed Safety Research Unit, 2881 F&B Road, College Station, Texas 77845, USA
| |
Collapse
|
2
|
Baker CA, De J, Bertoldi B, Dunn L, Chapin T, Jay-Russell M, Danyluk MD, Schneider KR. Prevalence and concentration of stx+ E. coli and E. coli O157 in bovine manure from Florida farms. PLoS One 2019; 14:e0217445. [PMID: 31125367 PMCID: PMC6534375 DOI: 10.1371/journal.pone.0217445] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Accepted: 05/10/2019] [Indexed: 12/25/2022] Open
Abstract
Fresh produce outbreaks due to Shiga toxin-producing Escherichia coli (STEC) continue to occur in the United States (US). Manure-amended soils can pose a public health risk when used for growing raw agricultural commodities. Knowing the prevalence and concentration of STEC in untreated biological soil amendments of animal origin (BSAAO) is important to help guide the most appropriate pre-harvest interval(s) following application to limit risks from these soil amendments. Bovine manure samples were collected from 12 farms in Florida, including samples from piles, lagoons, barns, and screened solids. Two methods were used to detect stx1/2 and rfbE genes in samples. A prevalence rate of 9% for stx1 and/or stx2 and 19% for rfbE was observed from the 518 bovine manure samples evaluated. A most probable number (MPN) assay was performed on stx+ samples when applicable. The geometric mean for stx+ samples (n = 20) was 3.37 MPN g-1 (0.53 log MPN g-1) with a maximum value of 6,800 MPN g-1 (3.83 log MPN g-1). This research was part of a larger nationwide geographical study on the prevalence and concentration of STEC in bovine manure to help guide regulations on feasible pre-harvest intervals for the application of untreated BSAAO.
Collapse
Affiliation(s)
- Christopher A. Baker
- Department of Food Science and Human Nutrition, University of Florida, Gainesville, Florida, United States of America
| | - Jaysankar De
- Department of Food Science and Human Nutrition, University of Florida, Gainesville, Florida, United States of America
| | - Bruna Bertoldi
- Department of Food Science and Human Nutrition, University of Florida, Gainesville, Florida, United States of America
| | - Laurel Dunn
- Citrus Research and Education Center, University of Florida, Lake Alfred, Florida, United States of America
| | - Travis Chapin
- Citrus Research and Education Center, University of Florida, Lake Alfred, Florida, United States of America
| | - Michele Jay-Russell
- Western Center for Food Safety, University of California, Davis, California, United States of America
| | - Michelle D. Danyluk
- Department of Food Science and Human Nutrition, University of Florida, Gainesville, Florida, United States of America
- Citrus Research and Education Center, University of Florida, Lake Alfred, Florida, United States of America
| | - Keith R. Schneider
- Department of Food Science and Human Nutrition, University of Florida, Gainesville, Florida, United States of America
- * E-mail:
| |
Collapse
|
3
|
Stromberg ZR, Lewis GL, Schneider LG, Erickson GE, Patel IR, Smith DR, Moxley RA. Culture-Based Quantification with Molecular Characterization of Non-O157 and O157 Enterohemorrhagic Escherichia coli Isolates from Rectoanal Mucosal Swabs of Feedlot Cattle. Foodborne Pathog Dis 2017; 15:26-32. [PMID: 29022742 DOI: 10.1089/fpd.2017.2326] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
Abstract
Enterohemorrhagic Escherichia coli (EHEC) strains are foodborne pathogens carried in the intestinal tracts of ruminants and shed in the feces. High concentrations (≥104 colony-forming units [CFU]/g) of EHEC in cattle feces are associated with contamination of hides, and subsequently, carcasses and beef. Several studies using agar media have quantified O157 but few have quantified non-O157 EHEC in samples from cattle. Thus, the objective of this study was to determine the concentration of O157 and non-O157 EHEC in cattle, and to characterize the associated EHEC isolates for their virulence potential. Two hundred feedlot steers were sampled by rectoanal mucosal swab (RAMS) every 35 days over four sampling periods, and a spiral plating method using modified Possé differential agar was used to quantify EHEC organisms in these samples. Bacterial colonies from agar plates were tested by multiplex PCR for Shiga toxin and intimin genes (stx and eae, respectively), and confirmed EHEC isolates (i.e., positive for both stx and eae) were serotyped and characterized for virulence genes using a microarray. Organisms detected in this study included O26, O101, O103, O109, O121, O145, O157, and O177 EHEC, with all except O121 quantifiable and measuring within a range from 9.0 × 102 to 3.0 × 105 CFU/g of RAMS sample. Organisms of the same EHEC serogroup were not detected in quantifiable concentrations from a single animal more than once. EHEC organisms most commonly detected at quantifiable levels were O26, O157, and O177. Interestingly, O26 EHEC isolates tested negative for stx1 but positive for stx2a. High concentrations of EHEC were detected in 11 (5.5%) of the steers at least once over the sampling period. These results indicate that in addition to O157, non-O157 EHEC are transiently present in high concentrations in the rectoanal mucosal region of cattle.
Collapse
Affiliation(s)
- Zachary R Stromberg
- 1 School of Veterinary Medicine and Biomedical Sciences, University of Nebraska-Lincoln , Lincoln, Nebraska
| | - Gentry L Lewis
- 1 School of Veterinary Medicine and Biomedical Sciences, University of Nebraska-Lincoln , Lincoln, Nebraska
| | - Liesel G Schneider
- 2 College of Veterinary Medicine, Mississippi State University , Mississippi State, Mississippi
| | - Galen E Erickson
- 3 Department of Animal Science, University of Nebraska-Lincoln , Lincoln, Nebraska
| | - Isha R Patel
- 4 Division of Molecular Biology, Office of Applied Research and Safety Assessment, Center for Food Safety and Applied Nutrition , United States Food and Drug Administration, Laurel, Maryland
| | - David R Smith
- 2 College of Veterinary Medicine, Mississippi State University , Mississippi State, Mississippi
| | - Rodney A Moxley
- 1 School of Veterinary Medicine and Biomedical Sciences, University of Nebraska-Lincoln , Lincoln, Nebraska
| |
Collapse
|
4
|
Shridhar PB, Noll LW, Cull CA, Shi X, Cernicchiaro N, Renter DG, Bai J, Nagaraja TG. Spiral Plating Method To Quantify the Six Major Non-O157 Escherichia coli Serogroups in Cattle Feces. J Food Prot 2017; 80:848-856. [PMID: 28414257 DOI: 10.4315/0362-028x.jfp-16-360] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2016] [Accepted: 12/20/2016] [Indexed: 01/01/2023]
Abstract
Cattle are a major reservoir of the six major Shiga toxin-producing non-O157 Escherichia coli (STEC) serogroups (O26, O45, O103, O111, O121, and O145) responsible for foodborne illnesses in humans. Besides prevalence in feces, the concentrations of STEC in cattle feces play a major role in their transmission dynamics. A subset of cattle, referred to as super shedders, shed E. coli O157 at high concentrations (≥4 log CFU/g of feces). It is not known whether a similar pattern of fecal shedding exists for non-O157. Our objectives were to initially validate the spiral plating method to quantify the six non-O157 E. coli serogroups with pure cultures and culture-spiked fecal samples and then determine the applicability of the method and compare it with multiplex quantitative PCR (mqPCR) assays for the quantification of the six non-O157 E. coli serogroups in cattle fecal samples collected from commercial feedlots. Quantification limits of the spiral plating method were 3 log, 3 to 4 log, and 3 to 5 log CFU/mL or CFU/g for individual cultures, pooled pure cultures, and cattle fecal samples spiked with pooled pure cultures, respectively. Of the 1,152 cattle fecal samples tested from eight commercial feedlots, 122 (10.6%) and 320 (27.8%) harbored concentrations ≥4 log CFU/g of one or more of the six serogroups of non-O157 by spiral plating and mqPCR methods, respectively. A majority of quantifiable samples, detected by either spiral plating (135 of 137, 98.5%) or mqPCR (239 of 320, 74.7%), were shedding only one serogroup. Only one of the quantifiable samples was positive for a serogroup carrying Shiga toxin (stx1) and intimin (eae) genes; 38 samples were positive for serogroups carrying the intimin gene. In conclusion, the spiral plating method can be used to quantify non-O157 serogroups in cattle feces, and our study identified a subset of cattle that was super shedders of non-O157 E. coli. The method has the advantage of quantifying non-O157 STEC, unlike mqPCR that quantifies serogroups only.
Collapse
Affiliation(s)
| | - Lance W Noll
- Department of Diagnostic Medicine and Pathobiology and
| | | | - Xiaorong Shi
- Department of Diagnostic Medicine and Pathobiology and
| | | | | | - Jianfa Bai
- Veterinary Diagnostic Laboratory, Kansas State University, Manhattan, Kansas 66506, USA
| | - T G Nagaraja
- Department of Diagnostic Medicine and Pathobiology and
| |
Collapse
|
5
|
Stromberg ZR, Lewis GL, Moxley RA. Comparison of Agar Media for Detection and Quantification of Shiga Toxin-Producing Escherichia coli in Cattle Feces. J Food Prot 2016; 79:939-49. [PMID: 27296597 DOI: 10.4315/0362-028x.jfp-15-552] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The isolation and quantification of non-O157 Shiga toxin-producing Escherichia coli (STEC) from cattle feces are challenging. The primary objective of this study was to evaluate the performance of selected agar media in an attempt to identify an optimal medium for the detection and quantification of non-O157 STEC in cattle feces. Comparison studies were performed using CHROMagar STEC, Possé differential agar (Possé), Possé modified by the reduction or addition of antimicrobials, STEC heart infusion washed blood agar with mitomycin C (SHIBAM), and SHIBAM modified by the addition of antimicrobials. Fourteen STEC strains, two each belonging to serogroups O26, O45, O103, O111, O121, O145, and O157, were used to test detection in inoculated fecal suspensions at concentrations of 10(2) or 10(3) CFU/g. One STEC strain from each of these seven serogroups was used to estimate the concentration of recovered STEC in feces inoculated at 10(3), 10(4), or 10(5) CFU/g. Significantly more suspensions (P < 0.05) were positive for STEC when plated on Possé containing reduced concentrations of novobiocin and potassium tellurite compared with SHIBAM, but not SHIBAM modified by containing these same antimicrobials at the same concentrations. Numerically, more suspensions were positive for STEC by using this same form of modified Possé compared with Possé, but this difference was not statistically significant. More suspensions were positive for STEC cultured on CHROMagar STEC compared with those on Possé (P < 0.05) and on modified Possé (P = 0.05). Most inoculated fecal suspensions below 10(4) CFU/g of feces were underestimated or not quantifiable for the concentration of STEC by using CHROMagar STEC or modified Possé. These results suggest that CHROMagar STEC performs better than Possé or SHIBAM for detection of STEC in bovine feces, but adjustments in the concentrations of novobiocin and potassium tellurite in the latter two media result in significant improvements in their performance.
Collapse
Affiliation(s)
- Zachary R Stromberg
- School of Veterinary Medicine and Biomedical Sciences, University of Nebraska-Lincoln, Lincoln, Nebraska 68583, USA
| | - Gentry L Lewis
- School of Veterinary Medicine and Biomedical Sciences, University of Nebraska-Lincoln, Lincoln, Nebraska 68583, USA
| | - Rodney A Moxley
- School of Veterinary Medicine and Biomedical Sciences, University of Nebraska-Lincoln, Lincoln, Nebraska 68583, USA.
| |
Collapse
|
6
|
Noll LW, Shridhar PB, Shi X, An B, Cernicchiaro N, Renter DG, Nagaraja TG, Bai J. A Four-Plex Real-Time PCR Assay, Based on rfbE, stx1, stx2, and eae Genes, for the Detection and Quantification of Shiga Toxin-Producing Escherichia coli O157 in Cattle Feces. Foodborne Pathog Dis 2015; 12:787-94. [PMID: 26317538 DOI: 10.1089/fpd.2015.1951] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Several real-time polymerase chain reaction (PCR) assays have been developed to detect and quantify Shiga toxin-producing Escherichia coli (STEC) O157:H7, but none have targeted the O-antigen specific gene (rfbEO157) in combination with the three major virulence genes, stx1, stx2, and eae. Our objectives were to develop and validate a four-plex, quantitative PCR (mqPCR) assay targeting rfbE(O157), stx1, stx2, and eae for the detection and quantification of STEC O157 in cattle feces, and compare the applicability of the assay to detect STEC O157 to a culture method and conventional PCR (cPCR) targeting the same four genes. Specificity of the mqPCR assay to differentially detect the four genes was confirmed with strains of O157 and non-O157 STEC with different profiles of target genes. In cattle feces spiked with pure cultures, detection limits were 2.8×10(4) and 2.8×10(0) colony-forming units/g before and after enrichment, respectively. Detection of STEC O157 in feedlot cattle fecal samples (n=278) was compared between mqPCR, cPCR, and a culture method. The mqPCR detected 48.9% (136/278) of samples as positive for E. coli O157. Of the 100 samples that were randomly picked from 136 mqPCR-positive samples, 35 and 48 tested positive by cPCR and culture method, respectively. Of the 100 samples randomly chosen from 142 mqPCR-negative samples, all were negative by cPCR, but 21 samples tested positive by the culture method. McNemar's chi-square tests indicated significant disagreement between the proportions of positive samples detected by the three methods. In conclusion, the mqPCR assay that targets four genes is a novel and more sensitive method than the cPCR or culture method to detect STEC O157 in cattle feces. However, the use of real-time PCR as a screening method to identify positive samples and then subjecting only positive samples to a culture method may underestimate the presence of STEC O157 in fecal samples.
Collapse
Affiliation(s)
- Lance W Noll
- 1 Department of Diagnostic Medicine/Pathobiology, Kansas State University , Manhattan, Kansas
| | - Pragathi B Shridhar
- 1 Department of Diagnostic Medicine/Pathobiology, Kansas State University , Manhattan, Kansas
| | - Xiaorong Shi
- 1 Department of Diagnostic Medicine/Pathobiology, Kansas State University , Manhattan, Kansas
| | - Baoyan An
- 2 Department of Veterinary Diagnostic Laboratory, College of Veterinary Medicine, Kansas State University , Manhattan, Kansas
| | - Natalia Cernicchiaro
- 1 Department of Diagnostic Medicine/Pathobiology, Kansas State University , Manhattan, Kansas
| | - David G Renter
- 1 Department of Diagnostic Medicine/Pathobiology, Kansas State University , Manhattan, Kansas
| | - Tiruvoor G Nagaraja
- 1 Department of Diagnostic Medicine/Pathobiology, Kansas State University , Manhattan, Kansas
| | - Jianfa Bai
- 2 Department of Veterinary Diagnostic Laboratory, College of Veterinary Medicine, Kansas State University , Manhattan, Kansas
| |
Collapse
|
7
|
Development of a quantitative real time PCR assay to detect and enumerate Escherichia coli O157 and O26 serogroups in bovine recto-anal swabs. J Microbiol Methods 2015; 114:9-15. [DOI: 10.1016/j.mimet.2015.04.005] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2015] [Revised: 04/16/2015] [Accepted: 04/16/2015] [Indexed: 01/29/2023]
|
8
|
Jacob ME, Bai J, Renter DG, Rogers AT, Shi X, Nagaraja TG. Comparing real-time and conventional PCR to culture-based methods for detecting and quantifying Escherichia coli O157 in cattle feces. J Food Prot 2014; 77:314-9. [PMID: 24490927 DOI: 10.4315/0362-028x.jfp-13-304] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Detection of Escherichia coli O157 in cattle feces has traditionally used culture-based methods; PCR-based methods have been suggested as an alternative. We aimed to determine if multiplex real-time (mq) or conventional PCR methods could reliably detect cattle naturally shedding high (≥10(4) CFU/g of feces) and low (∼10(2) CFU/g of feces) concentrations of E. coli O157. Feces were collected from pens of feedlot cattle and evaluated for E. coli O157 by culture methods. Samples were categorized as (i) high shedders, (ii) immunomagnetic separation (IMS) positive after enrichment, or (iii) culture negative. DNA was extracted pre- and postenrichment from 100 fecal samples from each category (high shedder, IMS positive, culture negative) and subjected to mqPCR and conventional PCR assays based on detecting three genes, rfbE, stx1, and stx2. In feces from cattle determined to be E. coli O157 high shedders by culture, 37% were positive by mqPCR prior to enrichment; 85% of samples were positive after enrichment. In IMS-positive samples, 4% were positive by mqPCR prior to enrichment, while 43% were positive after enrichment. In culture-negative feces, 7% were positive by mqPCR prior to enrichment, and 40% were positive after enrichment. The proportion of high shedder-positive and culture-positive (high shedder and IMS) samples were significantly different from mqPCR-positive samples before and after enrichment (P < 0.01). Similar results were observed for conventional PCR. Our data suggest that mqPCR and conventional PCR are most useful in identifying high shedder animals and may not be an appropriate substitute to culture-based methods for detection of E. coli O157 in cattle feces.
Collapse
Affiliation(s)
- M E Jacob
- Department of Population Health and Pathobiology, North Carolina State University, 1060 William Moore Drive, College of Veterinary Medicine, Raleigh, North Carolina 27607, USA.
| | - J Bai
- Department of Diagnostic Medicine/Pathobiology, Kansas State University, 1800 Denison Avenue, Manhattan, Kansas 66506, USA
| | - D G Renter
- Department of Diagnostic Medicine/Pathobiology, Kansas State University, 1800 Denison Avenue, Manhattan, Kansas 66506, USA
| | - A T Rogers
- Department of Population Health and Pathobiology, North Carolina State University, 1060 William Moore Drive, College of Veterinary Medicine, Raleigh, North Carolina 27607, USA
| | - X Shi
- Department of Diagnostic Medicine/Pathobiology, Kansas State University, 1800 Denison Avenue, Manhattan, Kansas 66506, USA
| | - T G Nagaraja
- Department of Diagnostic Medicine/Pathobiology, Kansas State University, 1800 Denison Avenue, Manhattan, Kansas 66506, USA
| |
Collapse
|
9
|
Morton J, Karoonuthaisiri N, Stewart LD, Oplatowska M, Elliott CT, Grant IR. Production and evaluation of the utility of novel phage display-derived peptide ligands to Salmonella spp. for magnetic separation. J Appl Microbiol 2013; 115:271-81. [PMID: 23551658 DOI: 10.1111/jam.12207] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2013] [Revised: 03/22/2013] [Accepted: 03/24/2013] [Indexed: 12/22/2022]
Abstract
AIMS The objectives of this study were to produce Salmonella-specific peptide ligands by phage display biopanning and evaluate their use for magnetic separation (MS). METHODS AND RESULTS Four-phage display biopanning rounds were performed, and the peptides expressed by the two most Salmonella-specific (on the basis of phage-binding ELISA results) phage clones, MSal020401 and MSal020417, were chemically synthesized and coupled to MyOne™ tosylactivated Dynabeads(®). Peptide capture capability for whole Salmonella cells from nonenriched broth cultures was quantified by MS + plate counts and MS + Greenlight™ detection and compared to capture capability of anti-Salmonella (antibody-coated) Dynabeads(®). MS + Greenlight™ gave a more comprehensive picture of capture capability than MS + plate counts and showed that Peptide MSal020417-coated beads exhibited at least similar, if not better, capture capability to anti-Salmonella Dynabeads(®) (mean capture values of 36·0 ± 18·2 and 31·2 ± 20·1%, respectively, over Salmonella spp. concentration range 3 × 10(1) -3 × 10(6) CFU ml(-1)) with cross-reactivity of ≤1·9% to three other foodborne pathogens: Escherichia coli, Listeria monocytogenes and Campylobacter jejuni. CONCLUSIONS One of the phage display-derived peptide ligands was demonstrated by MS + Greenlight™ to be a viable antibody alternative for MS of Salmonella spp. SIGNIFICANCE AND IMPACT OF THE STUDY This study demonstrates an antibody-free approach to Salmonella detection and opens substantial possibilities for more rapid tests for this bacterium.
Collapse
Affiliation(s)
- J Morton
- Institute for Global Food Security, School of Biological Sciences, Queen's University Belfast, Belfast, UK
| | | | | | | | | | | |
Collapse
|
10
|
Thomas P, Sekhar A, Mujawar M. Nonrecovery of varying proportions of viable bacteria during spread plating governed by the extent of spreader usage and proposal for an alternate spotting-spreading approach to maximize the CFU. J Appl Microbiol 2012; 113:339-50. [DOI: 10.1111/j.1365-2672.2012.05327.x] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
11
|
Rodgers JD, Lawes JR, Vidal AB, Ellis-Iversen J, Ridley A, Pleydell EJ, Powell LF, Toszeghy M, Stapleton K, Clifton-Hadley FA. Characteristics and comparative performance of direct culture, direct PCR and enumeration methods for detection and quantification of Campylobacter spp. in broiler caeca. Vet Microbiol 2012; 159:390-6. [PMID: 22565009 DOI: 10.1016/j.vetmic.2012.04.011] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2012] [Revised: 04/05/2012] [Accepted: 04/07/2012] [Indexed: 11/25/2022]
Abstract
Detection and enumeration of Campylobacter spp. in broiler chicken flocks are key components of research and surveillance studies aimed at reducing Campylobacter infections in people. Direct culture of caecal contents onto selective agar is the typical method used to confirm flock colonisation. Modified charcoal cefoperazone deoxycholate agar (mCCDA) is commonly used for this method, although alternative selective media have been used. Additionally, PCR methods to detect Campylobacter DNA from caecal contents may provide a rapid alternative. However comparative performance data for these methods is limited and therefore required to ensure optimal detection methods for this sample type. In this study, 306 broiler caeca were tested for Campylobacter using direct culture on mCCDA, Skirrows and Preston agars and two real-time PCR methods, one specific for mapA/ceuE regions and another for the flaA gene region. Additionally, the suitability of spread plating and spiral plating methods for enumeration of Campylobacter and the impact of sample storage were assessed. This study confirmed modified CCDA as an optimal media for detection of Campylobacter in broiler caeca. It was significantly more sensitive than Skirrows or Preston agars. This study also demonstrated that the mapA/ceuE PCR had excellent agreement with culture on mCCDA and is a genuine alternative method. Spread plating and spiral plating methods were suitable for enumeration although spiral plating appeared more sensitive for stored samples (72 h). A 1 log reduction in viable Campylobacters was observed in stored samples, therefore storage effects should be considered for quantitative studies with broiler caeca.
Collapse
Affiliation(s)
- J D Rodgers
- Department of Bacteriology, Animal Health and Veterinary Laboratories Agency Weybridge, United Kingdom.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Edrington TS, Farrow RL, Mackinnon KM, Callaway TR, Anderson RC, Nisbet DJ. Influence of vitamin D on fecal shedding of Escherichia coli O157:H7 in naturally colonized cattle. J Food Prot 2012; 75:314-9. [PMID: 22289592 DOI: 10.4315/0362-028x.jfp-11-335] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Three experiments were conducted to evaluate the influence of vitamin D on fecal shedding of Escherichia coli O157:H7 in cattle. In the first experiment, two groups of cattle (beef and dairy) were assigned to a control treatment or to receive 0.5 × 10(6) IU vitamin D per day via oral bolus for 10 days. Fecal samples were collected before and throughout the dosing period for culture of E. coli O157:H7. No differences were observed for fecal shedding of E. coli O157:H7 among treatments for either beef or dairy animals. Serum concentrations of vitamin D were markedly higher (P < 0.0001) in treated beef cattle but only tended to be higher (P = 0.09) in the dairy cattle. In the second experiment, three successive vitamin D dosages (2,400, 4,800, and 9,600 IU/day; 14 days each) were administered to 14 dairy steers (7 steers served as controls), fecal samples were collected daily, and serum samples were collected weekly throughout the 42-day experimental period. No significant differences in fecal prevalence or serum vitamin D concentrations were observed for any of the vitamin D dosages. A third experiment sampled feedlot cattle (winter and summer) to determine whether serum vitamin D concentrations were correlated with fecal shedding of E. coli O157:H7. A fecal sample and a blood sample were obtained in each season from 60 randomly selected animals (total of 120 fecal samples and 120 corresponding blood samples). As expected, season was highly correlated (r = 0.66) with serum vitamin D concentration with higher concentrations (P < 0.01) observed in the summer. E. coli O157:H7 prevalence (percentage of positive samples) was not highly correlated (r = 0.16) with season, although the correlation tended to be significant (P = 0.08). The proportion of cattle shedding E. coli O157:H7 was 16.7 and 6.7% for the summer and winter collections, respectively. Results of this research do not support a correlation between vitamin D intake and E. coli O157:H7 shedding in cattle.
Collapse
Affiliation(s)
- Tom S Edrington
- U.S. Department of Agriculture, Agricultural Research Service, Food and Feed Safety Research Unit, Southern Plains Agricultural Research Center, College Station, TX 77845, USA.
| | | | | | | | | | | |
Collapse
|
13
|
Edrington TS, Carter BH, Farrow RL, Islas A, Hagevoort GR, Friend TH, Callaway TR, Anderson RC, Nisbet DJ. Influence of Weaning on Fecal Shedding of Pathogenic Bacteria in Dairy Calves. Foodborne Pathog Dis 2011; 8:395-401. [DOI: 10.1089/fpd.2010.0686] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
Affiliation(s)
- Tom S. Edrington
- Food and Feed Safety Research Unit, Southern Plains Agricultural Research Center, Agricultural Research Service, U.S. Department of Agriculture, College Station, Texas
| | - Boone H. Carter
- Department of Animal and Range Sciences, New Mexico State University, Las Cruces, New Mexico
| | - Russell L. Farrow
- Food and Feed Safety Research Unit, Southern Plains Agricultural Research Center, Agricultural Research Service, U.S. Department of Agriculture, College Station, Texas
| | - Alfonso Islas
- Department of Animal and Range Sciences, New Mexico State University, Las Cruces, New Mexico
| | - G. Robert Hagevoort
- Agricultural Experiment Station, New Mexico State University, Clovis, New Mexico
| | - Ted H. Friend
- Department of Animal Science, Texas A&M University, College Station, Texas
| | - Todd R. Callaway
- Food and Feed Safety Research Unit, Southern Plains Agricultural Research Center, Agricultural Research Service, U.S. Department of Agriculture, College Station, Texas
| | - Robin C. Anderson
- Food and Feed Safety Research Unit, Southern Plains Agricultural Research Center, Agricultural Research Service, U.S. Department of Agriculture, College Station, Texas
| | - David J. Nisbet
- Food and Feed Safety Research Unit, Southern Plains Agricultural Research Center, Agricultural Research Service, U.S. Department of Agriculture, College Station, Texas
| |
Collapse
|
14
|
Jasson V, Jacxsens L, Luning P, Rajkovic A, Uyttendaele M. Alternative microbial methods: An overview and selection criteria. Food Microbiol 2010; 27:710-30. [DOI: 10.1016/j.fm.2010.04.008] [Citation(s) in RCA: 193] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2009] [Revised: 04/12/2010] [Accepted: 04/20/2010] [Indexed: 11/25/2022]
|
15
|
Edrington TS, MacDonald JC, Farrow RL, Callaway TR, Anderson RC, Nisbet DJ. Influence of Wet Distiller's Grains on Prevalence of Escherichia coli O157:H7 and Salmonella in Feedlot Cattle and Antimicrobial Susceptibility of Generic Escherichia coli Isolates. Foodborne Pathog Dis 2010; 7:605-8. [DOI: 10.1089/fpd.2009.0417] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Tom S. Edrington
- Food and Feed Safety Research Unit, Southern Plains Agricultural Research Center, Agricultural Research Service, U.S. Department of Agriculture, College Station, Texas
| | | | - Russell L. Farrow
- Food and Feed Safety Research Unit, Southern Plains Agricultural Research Center, Agricultural Research Service, U.S. Department of Agriculture, College Station, Texas
| | - Todd R. Callaway
- Food and Feed Safety Research Unit, Southern Plains Agricultural Research Center, Agricultural Research Service, U.S. Department of Agriculture, College Station, Texas
| | - Robin C. Anderson
- Food and Feed Safety Research Unit, Southern Plains Agricultural Research Center, Agricultural Research Service, U.S. Department of Agriculture, College Station, Texas
| | - David J. Nisbet
- Food and Feed Safety Research Unit, Southern Plains Agricultural Research Center, Agricultural Research Service, U.S. Department of Agriculture, College Station, Texas
| |
Collapse
|
16
|
Edrington TS, Farrow RL, Loneragan GH, Ives SE, Engler MJ, Wagner JJ, Corbin MJ, Platter WJ, Yates D, Hutcheson JP, Zinn RA, Callaway TR, Anderson RC, Nisbet DJ. Influence of beta-agonists (ractopamine HCl and zilpaterol HCl) on fecal shedding of Escherichia coli O157:H7 in feedlot cattle. J Food Prot 2009; 72:2587-91. [PMID: 20003743 DOI: 10.4315/0362-028x-72.12.2587] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Ractopamine HCl and zilpaterol HCl, beta-agonists recently approved for use in feedlot cattle to improve performance traits and carcass leanness, were examined for their effects on fecal shedding of Escherichia coli O157:H7 in feedlot cattle. Fecal samples (n = 2,454) were obtained from four experiments (one ractopamine HCl, three zilpaterol HCl) over the course of a 3-year period, either by rectal palpation (ractopamine HCl experiment) or from pen-floor fecal pats. Samples were cultured quantitatively and qualitatively for E. coli O157:H7. No significant treatment differences were detected for fecal prevalence of E. coli O157:H7 in the ractopamine HCl experiment. Zilpaterol HCl feeding had no effect (P > 0.20) on fecal shedding in the first or second experiments, with overall E. coli O157:H7 prevalence relatively low (<7%). In the third zilpaterol HCl experiment, the percentage of fecal samples that were E. coli O157:H7 positive following qualitative culture was higher (P < 0.05) in the zilpaterol HCl treatment (10.3%) than for the control (6.1%). The current research showed minimal effects of beta-agonists on fecal shedding of E. coli O157:H7 and indicated that these compounds (fed immediately prior to slaughter) are not a cause for concern from a food safety standpoint.
Collapse
Affiliation(s)
- Tom S Edrington
- Food and Feed Safety Research Unit, Agricultural Research Service, U.S. Department of Agriculture, College Station, Texas 77845, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Quantifying within- and between-animal variation and uncertainty associated with counts of Escherichia coli O157 occurring in naturally infected cattle faeces. J R Soc Interface 2009; 6:169-77. [PMID: 18647739 DOI: 10.1098/rsif.2008.0183] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Cattle faeces are considered the most important reservoir for human infection with Escherichia coli O157. We have previously described shedding of E. coli O157 in the faeces of naturally infected cattle cohorts. However, the data require further investigation to quantify the uncertainty and variability in the estimates previously presented. This paper proposes a method for analysing both the presence and the quantity of E. coli O157 in cattle faecal samples, using two isolation procedures, one of which enumerates E. coli O157. The combination of these two measurements, which are fundamentally different in nature and yet measuring a common outcome, has necessitated the development of a novel statistical model for ascertaining the contribution of the various components of variation (both natural and observation induced) and for judging the influence of explanatory variables. Most of the variation within the sampling hierarchy was attributable to multiple samples from the same animal. The contribution of laboratory-level variation was found to be low. After adjusting for fixed and random effects, short periods of increased intensity of shedding were identified in individual animals. We conclude that within-animal variation is greater than between animals over time, and studies aiming to elucidate the dynamics of shedding should focus resources, sampling more within than between animals. These findings have implications for the identification of persistent high shedders and for assessing their role in the epidemiology of E. coli O157 in cattle populations. The development of this non-standard statistical model may have many applications to other microbial count data.
Collapse
|
18
|
Smith R, Ellis-Iversen J, Snary E, Clifton-Hadley F, Paiba G. Factors influencing the presence and concentration ofE. coliO157 andE. coliin farm waste on six cattle farms in North-West England. J Appl Microbiol 2009; 106:613-23. [DOI: 10.1111/j.1365-2672.2008.04033.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
19
|
Berry ED, Wells JE. A direct plating method for estimating populations of Escherichia coli O157 in bovine manure and manure-based materials. J Food Prot 2008; 71:2233-8. [PMID: 19044267 DOI: 10.4315/0362-028x-71.11.2233] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Escherichia coli O157:H7 outbreaks associated with produce consumption have brought attention to livestock manures and manure-based soil amendments as potential sources of pathogens for the contamination of these crops. Procedures for enumeration of E. coli O157:H7 are needed to assess the risks of transmission from these manures and their by-products. A direct plating method employing spiral plating onto CHROMagar O157 was investigated for enumeration of E. coli O157:H7 in feedlot surface material, aged bovine manure, bovine manure compost, and manure-amended soil. In studies utilizing samples spiked with a five-strain cocktail of E. coli O157:H7 at levels ranging from 102 to 10(5) CFU/g of sample, there were strong correlations between the observed and predicted levels of this pathogen. Although the addition of 2.5 mg/liter potassium tellurite and 5 mg/liter novobiocin made the medium more restrictive, these amendments enhanced the ability to identify and enumerate E. coli O157:H7 in feedlot surface material, which contained a higher proportion of fresh feces than did the other three sample types and therefore higher levels of interfering bacterial microflora. The spiral plating method was further assessed to determine its ability to enumerate E. coli O157:H7 in naturally contaminated feedlot surface material. Comparison of E. coli O157:H7 counts in feedlot surface material obtained by the spiral plating method and a most probable number technique were well correlated. We conclude that direct spiral plating onto CHROMagar O157 is effective for estimating E. coli O157:H7 levels in a variety of manures and manure-containing sample types to a lower detection limit of 200 CFU/g. The method has application for determining E. coli O157:H7 concentrations in manures and composts before their sale and use as soil amendments and for measuring the effectiveness of manure treatment processes to reduce or inactivate this pathogen.
Collapse
Affiliation(s)
- Elaine D Berry
- U.S. Department of Agriculture, Agricultural Research Service, Roman L. Hruska U.S. Meat Animal Research Center, P.O. Box 166, Spur 18D, Clay Center, Nebraska 68933-0166, USA.
| | | |
Collapse
|
20
|
Fox JT, Renter DG, Sanderson MW, Nutsch AL, Shi X, Nagaraja TG. Associations between the presence and magnitude of Escherichia coli O157 in feces at harvest and contamination of preintervention beef carcasses. J Food Prot 2008; 71:1761-7. [PMID: 18810859 DOI: 10.4315/0362-028x-71.9.1761] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
To quantify associations at slaughter between Escherichia coli O157 carcass contamination, fecal-positive animals, and high-shedding animals within truckloads of finished cattle, we sampled up to 32 cattle from each of 50 truckloads arriving at a commercial abattoir in the Midwest United States during a 5-week summer period. Carcass swab samples collected pre-evisceration and fecal samples collected postevisceration were matched within animals and analyzed for the presence of E. coli O157, using enrichment, immunomagnetic separation, and plating on selective media (IMS). In addition, a direct plating procedure was performed on feces to identify high-shedding animals. E. coli O157 was isolated from 39 (2.6%) of 1,503 carcass samples in 15 (30%) truckloads, and 127 (8.5%) of 1,495 fecal samples in 37 (74%) truckloads. Fifty-five (3.7%) high-shedding animals were detected from 26 (52%) truckloads. Truckload high-shedder (Spearman rank-order correlation coefficient [r(s)] = 0.68), IMS-positive (r(s) = 0.48), and combined fecal (r(s) = 0.61) prevalence were significantly correlated with carcass prevalence. The probability of isolating E. coli O157 from a carcass was not significantly associated with the high-shedder or fecal IMS status of the animal from which the carcass was derived. However, the probability of carcass contamination was significantly associated with all truckload-level measures of fecal E. coli O157, particularly whether or not a high shedder was present within the truckload (odds ratio = 16.2; 95% confidence interval, 6.3-43.6). Our results suggest that high shedders within a truckload at slaughter could be a target for mitigation strategies to reduce the probability of preevisceration carcass contamination.
Collapse
Affiliation(s)
- J T Fox
- Department of Diagnostic Medicine and Pathobiology, College of Veterinary Medicine, Kansas State University, Manhattan, Kansas 66506-5606, USA
| | | | | | | | | | | |
Collapse
|
21
|
Salmonella and Escherichia coli O157:H7 contamination on hides and carcasses of cull cattle presented for slaughter in the United States: an evaluation of prevalence and bacterial loads by immunomagnetic separation and direct plating methods. Appl Environ Microbiol 2008; 74:6289-97. [PMID: 18723661 DOI: 10.1128/aem.00700-08] [Citation(s) in RCA: 116] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The hide and carcass hygiene of cull cattle at slaughter in four geographically distant regions of the United States was examined from July 2005 to April 2006 by measuring the aerobic plate counts (APC) and the prevalences and loads of Salmonella and Escherichia coli O157:H7. The geometric mean log(10) APC CFU/100 cm(2) levels on hides and preevisceration and postintervention carcasses ranged from 6.17 to 8.19, 4.24 to 6.47, and 1.46 to 1.96, respectively, and were highest in the summer (P < 0.0001). The average prevalences of Salmonella on hides and preevisceration and postintervention carcasses were 89.6% (95% confidence interval [CI], 85.1 to 94.0), 50.2% (95% CI, 40.9 to 59.5), and 0.8% (95% CI, 0.18 to 1.42), respectively. The prevalences of E. coli O157:H7 were 46.9% (95% CI, 37.3 to 56.6) and 16.7% (95% CI, 9.8 to 23.6) on hides and preevisceration carcasses, respectively. Examination of the concomitant incidence of Salmonella and E. coli O157:H7 showed that, on average, 33.3% (95% CI, 15.9 to 69.8) of cattle hide and 4.1% (95% CI, 0.98 to 17.3) of preevisceration carcass samples were contaminated with both pathogens. The pathogen prevalence on hides and carcasses was not significantly affected by the season; however, significant differences were observed between plants with respect to the incoming pathogen load and the ability to mitigate hide-to-carcass transfer. In spite of these differences, postintervention carcass contamination was significantly reduced (P < 0.001), likely as a result of the use of one or more of the processing interventions employed at each of the four processing plants examined.
Collapse
|
22
|
Arnold ME, Ellis-Iversen J, Cook AJC, Davies RH, McLaren IM, Kay ACS, Pritchard GC. Investigation into the Effectiveness of Pooled Fecal Samples for Detection of Verocytotoxin-Producing Escherichia Coli O157 in Cattle. J Vet Diagn Invest 2008; 20:21-7. [DOI: 10.1177/104063870802000104] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Verocytotoxin-producing Escherichia coli O157 (VTEC O157) may cause severe illness in people. Cattle are regarded as an important source of VTEC O157, and in an outbreak investigation, there is a necessity to establish whether or not the putative contact herd shares infection with the human case. The effectiveness of a herd investigation is impacted by the number of samples required, which will influence the time taken to collect samples and then process these in the laboratory. The objective of this study was to investigate the effectiveness of pooled sampling for detecting VTEC O157 in cattle herds in the United Kingdom. On farm 1, 150 individual fecal samples were collected during the course of a VTEC O157 outbreak investigation. One-gram and 10-g subsamples were tested from each individual sample. Once the culture results of the individual sample were known, pools comprising 5 and 10 individual samples were formed, with each pool containing a known number of positive samples. This data showed that the sensitivity of pooled sampling depended upon the proportion of positive samples in the pool. Further samples were collected from 2 more infected farms (2 and 3). Each individual sample was tested in duplicate. Pools of 5 feces were formed on-farm, and half the number of pooled feces were tested as individual feces. There was no significant difference between the number of cultures required for pooled sampling, as was the same for individual sampling, and therefore pooling did not improve the effectiveness of detection of VTEC O157.
Collapse
Affiliation(s)
- Mark E. Arnold
- Centre for Epidemiology and Risk Analysis, Veterinary Laboratory Agency (VLA), New Haw, Addlestone, Surrey, UK
| | - Johanne Ellis-Iversen
- Centre for Epidemiology and Risk Analysis, Veterinary Laboratory Agency (VLA), New Haw, Addlestone, Surrey, UK
| | - Alasdair J. C. Cook
- Centre for Epidemiology and Risk Analysis, Veterinary Laboratory Agency (VLA), New Haw, Addlestone, Surrey, UK
| | - Robert H. Davies
- Department of Food and Environmental Safety, Veterinary Laboratory Agency (VLA), New Haw, Addlestone, Surrey, UK
| | - Ian M. McLaren
- Department of Food and Environmental Safety, Veterinary Laboratory Agency (VLA), New Haw, Addlestone, Surrey, UK
| | | | | |
Collapse
|
23
|
Scientific Opinion of the Panel on Biological Hazards (BIOHAZ) - Monitoring of verotoxigenic Escherichia coli (VTEC) and identification of human pathogenic VTEC types. EFSA J 2007. [DOI: 10.2903/j.efsa.2007.579] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
|
24
|
Brichta-Harhay D, Arthur T, Bosilevac J, Guerini M, Kalchayanand N, Koohmaraie M. Enumeration of Salmonella and Escherichia coli O157:H7 in ground beef, cattle carcass, hide and faecal samples using direct plating methods†. J Appl Microbiol 2007; 103:1657-68. [DOI: 10.1111/j.1365-2672.2007.03405.x] [Citation(s) in RCA: 90] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
25
|
Fox JT, Renter DG, Sanderson MW, Thomson DU, Lechtenberg KF, Nagaraja TG. Evaluation of culture methods to identify bovine feces with high concentrations of Escherichia coli O157. Appl Environ Microbiol 2007; 73:5253-60. [PMID: 17574994 PMCID: PMC1950981 DOI: 10.1128/aem.00554-07] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Our objective was to evaluate methods for identifying cattle with high concentrations of Escherichia coli O157 in their feces. In two experiments, feces were collected from cattle orally inoculated with nalidixic acid (Nal)-resistant E. coli O157, and direct plating of diluted feces on sorbitol MacConkey agar with cefixime and potassium tellurite (CT-SMAC) containing Nal was considered the gold standard (GS) method. In experiment 1, methods evaluated were preenrichment direct streak, immunomagnetic separation with most probable number (MPN), and postenrichment direct streak with MPN, all using CT-SMAC. The mean concentration of Nal-resistant E. coli O157 in samples (n = 59) by use of the GS was 3.6 log10 CFU/g. The preenrichment streak detected >3.0 log10 CFU/g samples with a 74.4% sensitivity and 68.8% specificity. Postenrichment direct streak-MPN and immunomagnetic separation-MPN concentrations were correlated significantly with GS concentrations (r = 0.53 and r = 0.39, respectively). In experiment 2 (480 samples), pre- and postenrichment direct streaking performed in triplicate and spiral plating on CT-SMAC were evaluated. For preenrichment streaks, sensitivity was 79.7% and specificity was 96.7% for detecting >3.0 log10 CFU/g when the criterion was positive cultures on at least two plates. For spiral plating at that concentration, sensitivity and specificity were 83.9% and 56.3%, respectively. Postenrichment streaking performed relatively poorly. Triplicate preenrichment streaks of 1:10-diluted feces on CT-SMAC may be useful for identifying cattle shedding high concentrations of E. coli O157. Estimates of sensitivity and specificity enable appropriate application of methods and interpretation of results and may enhance applied research, surveillance, and risk assessments.
Collapse
Affiliation(s)
- J Trent Fox
- Department of Diagnostic Medicine and Pathobiology, Kansas State University, Manhattan, KS 66506, USA
| | | | | | | | | | | |
Collapse
|
26
|
Stephens TP, Loneragan GH, Chaney WE, Branham LA, Brashears MM. Development and validation of a most-probable-numberimmunomagnetic separation methodology of enumerating Escherichia coli O157 in cattle feces. J Food Prot 2007; 70:1072-5. [PMID: 17536662 DOI: 10.4315/0362-028x-70.5.1072] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A method to validate enumeration of Escherichia coli O157 in fecal samples from feedlot cattle was developed in these studies. Due to background flora, bovine fecal sample enumeration cannot be performed by simple direct plating techniques. Known quantities of E. coli O157:H7 were inoculated into feces, and populations were determined by direct plating of the cocktail (studies 1, 2, and 3) and manure and cocktail (studies 4 and 5) mixtures and compared with a most-probable-number (MPN)-immunomagnetic separation (IMS) method. The three-tube MPN combined preenrichment in gram-negative broth with confirmation using IMS. Five separate enumeration studies (study 1, sterile feces inoculated with 10(2) E. coli O157:H7 per g; study 2, nonsterile feces inoculated with 10(3) E. coli O157:H7 per g; study 3, nonsterile feces inoculated with 10(1) E. coli O157:H7 per g; study 4, sterile feces inoculated with 10(4) streptomycin-resistant E. coli O157:H7 per g; and study 5, sterile feces inoculated with 10(2) streptomycin-resistant E. coli O157:H7 per g) were conducted. These studies were performed to determine the precision, accuracy, and specificity at low and high levels of pathogen contamination in feces, using direct plating compared with the MPN-IMS methodology tested. There was an overall difference (P < 0.01) between direct plating and MPN-IMS methodologies, but this difference was biologically negligible due to the difference in least-squares means (0.29 +/- 0.10) being so low. The direct plating and MPN-IMS methods were correlated (r = 0.93). These results suggest that using the MPN-IMS procedures is an effective method of estimating E. coli O157 populations in naturally infected bovine fecal samples.
Collapse
Affiliation(s)
- T P Stephens
- Department of Animal and Food Sciences, International Center for Food Industry Excellence, Texas Tech University, Lubbock, Texas 79409, USA
| | | | | | | | | |
Collapse
|
27
|
Arthur TM, Bosilevac JM, Brichta-Harhay DM, Guerini MN, Kalchayanand N, Shackelford SD, Wheeler TL, Koohmaraie M. Transportation and lairage environment effects on prevalence, numbers, and diversity of Escherichia coli O157:H7 on hides and carcasses of beef cattle at processing. J Food Prot 2007; 70:280-6. [PMID: 17340859 DOI: 10.4315/0362-028x-70.2.280] [Citation(s) in RCA: 104] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Hide has been established as the main source of carcass contamination during cattle processing; therefore, it is crucial to minimize the amount of Escherichia coli O157:H7 on cattle hides before slaughter. Several potential sources of E. coli O157: H7 are encountered during transportation and in the lairage environment at beef-processing facilities that could increase the prevalence and numbers of E. coli O157:H7 on the hides of cattle. On three separate occasions, samples were obtained from cattle at the feedlot and again after cattle were stunned and exsanguinated at the processing plant (286 total animals). The prevalence of E. coli O157:H7 on hides increased from 50.3 to 94.4% between the time cattle were loaded onto tractor-trailers at the feedlot and the time hides were removed in the processing plant. Before transport, nine animals had E. coli O157:H7 in high numbers (> 0.4 CFU/cm2) on their hides. When sampled at the slaughter facility, the number of animals with high hide numbers had increased to 70. Overall, only 29% of the E. coli O157:H7 isolates collected postharvest (221 of 764) matched pulsed-field gel electrophoresis types collected before transport. The results of this study indicate that transport to and lairage at processing plants can lead to increases in the prevalence and degree of E. coli O157:H7 contamination on hides and the number of E. coli O157:H7 pulsed-field gel electrophoresis types associated with the animals. More study is needed to confirm the mechanism by which additional E. coli O157:H7 strains contaminate cattle hides during transport and lairage and to design interventions to prevent this contamination.
Collapse
Affiliation(s)
- Terrance M Arthur
- U.S. Department of Agriculture, Agricultural Research Service, Roman L. Hruska U.S. Meat Animal Research Center, Clay Center, Nebraska 68933-0166, USA.
| | | | | | | | | | | | | | | |
Collapse
|
28
|
LeJeune JT, Hancock DD, Besser TE. Sensitivity of Escherichia coli O157 detection in bovine feces assessed by broth enrichment followed by immunomagnetic separation and direct plating methodologies. J Clin Microbiol 2006; 44:872-5. [PMID: 16517869 PMCID: PMC1393073 DOI: 10.1128/jcm.44.3.872-875.2006] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
In order to more precisely predict food safety risks, the fecal presence of food-borne pathogens among animals at slaughter must be correctly determined. Quantification of Escherichia coli O157 is also desirable. In two separate experiments, detection and enumeration of a nalidixic acid-resistant strain of E. coli O157 in bovine feces was assessed by culture on MacConkey agar supplemented with nalidixic acid (MACnal) and compared to overnight broth enrichment followed by immunomagnetic separation (IMS) and to direct plating of dilutions of bovine feces onto sorbitol MacConkey agar containing cefixime and tellurite (SMACct). The sensitivity of detection of E. coli O157 by both direct plating and IMS was highly dependent upon the initial concentration of the target organism in the sample. Sensitivity of detection by IMS was poor below 100 CFU/g but was better, and not affected by initial E. coli O157 numbers, above this concentration. Sensitivity of detection of E. coli O157 in bovine feces at low initial concentrations is very poor for both direct plating and IMS. Direct plating of dilutions of bovine feces on SMACct can be used to determine the magnitude of fecal E. coli excretion among cattle excreting greater than 100 CFU/g. Among positive samples identified by direct plating on SMACct, the direct counts of E. coli O157:H7 were highly correlated with the estimates obtained with the MACnal plates (r = 0.88, P < 0.001). Because the majority of cattle excrete less than 10(2) CFU E. coli O157/g feces, most studies, including those using IMS methods, probably grossly underestimate the prevalence of E. coli O157 in cattle.
Collapse
Affiliation(s)
- Jeffrey T LeJeune
- Food Animal Health Research Program, Ohio Agricultural Research and Development Center, The Ohio State University, 1680 Madison Ave., Wooster, Ohio 44691, USA.
| | | | | |
Collapse
|
29
|
Schultz CL, Edrington TS, Schroeder SB, Hallford DM, Genovese KJ, Callaway TR, Anderson RC, Nisbet DJ. Effect of the thyroid on faecal shedding of E. coli O157:H7 and Escherichia coli in naturally infected yearling beef cattle. J Appl Microbiol 2006; 99:1176-80. [PMID: 16238748 DOI: 10.1111/j.1365-2672.2005.02705.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
AIMS To determine if thyroid function affects faecal shedding of Escherichia coli O157:H7. METHODS AND RESULTS Eight yearling cattle (n = 4 per treatment group), previously identified as shedding E. coli O157:H7, received either 0 or 10 mg 6-N-propyl-2-thiouracil (PTU) kg(-1) BW day(-1) for 14 days to reduce serum concentrations of the thyroid hormones, T(3) and T(4). Animals were monitored daily for changes in faecal shedding of E. coli O157:H7 and E. coli (EC) for the 14-day treatment period and an additional 7 days post-treatment. Body weight was measured weekly and serum concentrations of T(3) and T(4) were determined every 3 days. No differences in faecal shedding of E. coli O157:H7 were observed during the 14-day treatment period. However, compared with control animals, a greater percentage of PTU-treated cattle ejected E. coli O157:H7 on day 16 (100 vs 25%) and 18 (75 vs 0%) of the post-treatment period. Serum T(3) was lower in PTU-treated cattle during the 14-day treatment period and greater on day 18 of the post-treatment period. CONCLUSION Cattle with chemically altered thyroid hormones had similar shedding patterns of faecal E. coli O157:H7 and EC during the 14-day treatment period. However, faecal shedding of E. coli O157:H7 tended to be greater, and serum concentrations of T(3), were greater for PTU-treated cattle immediately following the termination of PTU treatment. SIGNIFICANCE AND IMPACT OF THE STUDY Short-term chemical inhibition of thyroid hormones had minimal effects on faecal shedding of E. coli O157:H7 in naturally infected cattle. However, a hyperthyroid state as observed postdosing might play a role in the seasonal shedding of E. coli O157:H7 in cattle.
Collapse
Affiliation(s)
- C L Schultz
- USDA/ARS-Southern Plains Agricultural Research Center, College Station, TX 77845, USA
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Hirota K, Murakami K, Nemoto K, Miyake Y. Coating of a surface with 2-methacryloyloxyethyl phosphorylcholine (MPC) co-polymer significantly reduces retention of human pathogenic microorganisms. FEMS Microbiol Lett 2006; 248:37-45. [PMID: 15953697 DOI: 10.1016/j.femsle.2005.05.019] [Citation(s) in RCA: 83] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2005] [Revised: 05/10/2005] [Accepted: 05/12/2005] [Indexed: 11/30/2022] Open
Abstract
The present study compares the retention of four species that are often isolated in association with biomedical device-related infections - Staphylococcus aureus, Streptococcus mutans, Pseudomonas aeruginosa, and Candida albicans - to three different surfaces. All four bacterial species were found to bind significantly less well to MPC-coated surfaces than to non-coated surfaces. We attribute this effect to the "superhydrophilicity" of MPC-coated surfaces, whereas hydrophobic surfaces are well known to reduce bacterial retention and thus to inhibit a crucial step in the formation of bacterial biofilms that lead to biomedical device-related infections and complications.
Collapse
Affiliation(s)
- Katsuhiko Hirota
- Department of Microbiology, Institute of Health Biosciences, Tokushima University Graduate School, Tokushima 770-8504, Japan
| | | | | | | |
Collapse
|
31
|
Erratum. J Appl Microbiol 2005. [DOI: 10.1111/j.1365-2672.2005.02557.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
32
|
Robinson SE, Brown PE, John Wright E, Bennett M, Hart CA, French NP. Heterogeneous distributions ofEscherichia coliO157 within naturally infected bovine faecal pats. FEMS Microbiol Lett 2005; 244:291-6. [PMID: 15766781 DOI: 10.1016/j.femsle.2005.01.056] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2004] [Revised: 12/02/2004] [Accepted: 01/31/2005] [Indexed: 11/22/2022] Open
Abstract
Escherichia coli O157 is an important human pathogen for which cattle are considered a reservoir. This paper describes and models the variation in counts of E. coli O157 that exists within individual bovine faecal pats. The presence and concentration of E. coli O157 in faecal samples was determined using a combination of direct spiral plating followed by a more sensitive isolation procedure. The data were modelled using multilevel random effect models, in which the random effects were allowed to be correlated to allow for the fact that pooled and individual samples come from the same pat. Up to a two log difference in the concentration of E. coli O157 was demonstrated in samples from different areas within a faecal pat. Pooling of individual samples from throughout the faecal pat and processing it as one composite sample allows this heterogeneity to be overcome.
Collapse
Affiliation(s)
- Susan E Robinson
- DEFRA Epidemiology Fellowship Unit, University of Liverpool, Leahurst, Neston, South Wirral, UK.
| | | | | | | | | | | |
Collapse
|