1
|
Zhuang L, Gong J, Zhao Y, Yang J, Liu G, Zhao B, Song C, Zhang Y, Shen Q. Progress in methods for the detection of viable Escherichia coli. Analyst 2024; 149:1022-1049. [PMID: 38273740 DOI: 10.1039/d3an01750h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2024]
Abstract
Escherichia coli (E. coli) is a prevalent enteric bacterium and a necessary organism to monitor for food safety and environmental purposes. Developing efficient and specific methods is critical for detecting and monitoring viable E. coli due to its high prevalence. Conventional culture methods are often laborious and time-consuming, and they offer limited capability in detecting potentially harmful viable but non-culturable E. coli in the tested sample, which highlights the need for improved approaches. Hence, there is a growing demand for accurate and sensitive methods to determine the presence of viable E. coli. This paper scrutinizes various methods for detecting viable E. coli, including culture-based methods, molecular methods that target DNAs and RNAs, bacteriophage-based methods, biosensors, and other emerging technologies. The review serves as a guide for researchers seeking additional methodological options and aiding in the development of rapid and precise assays. Moving forward, it is anticipated that methods for detecting E. coli will become more stable and robust, ultimately contributing significantly to the improvement of food safety and public health.
Collapse
Affiliation(s)
- Linlin Zhuang
- School of Animal Husbandry and Veterinary Medicine, Jiangsu Vocational College of Agriculture and Forestry, Jurong 212400, P. R. China.
- State Key Laboratory of Digital Medical Engineering, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering & Basic Medicine Research and Innovation Center of Ministry of Education, Zhongda Hospital, Southeast University, Nanjing 211102, P. R. China.
| | - Jiansen Gong
- Poultry Institute, Chinese Academy of Agricultural Sciences, Yangzhou 225125, P. R. China
| | - Ying Zhao
- State Key Laboratory of Digital Medical Engineering, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering & Basic Medicine Research and Innovation Center of Ministry of Education, Zhongda Hospital, Southeast University, Nanjing 211102, P. R. China.
| | - Jianbo Yang
- School of Animal Husbandry and Veterinary Medicine, Jiangsu Vocational College of Agriculture and Forestry, Jurong 212400, P. R. China.
| | - Guofang Liu
- School of Animal Husbandry and Veterinary Medicine, Jiangsu Vocational College of Agriculture and Forestry, Jurong 212400, P. R. China.
| | - Bin Zhao
- School of Animal Husbandry and Veterinary Medicine, Jiangsu Vocational College of Agriculture and Forestry, Jurong 212400, P. R. China.
| | - Chunlei Song
- School of Animal Husbandry and Veterinary Medicine, Jiangsu Vocational College of Agriculture and Forestry, Jurong 212400, P. R. China.
| | - Yu Zhang
- State Key Laboratory of Digital Medical Engineering, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering & Basic Medicine Research and Innovation Center of Ministry of Education, Zhongda Hospital, Southeast University, Nanjing 211102, P. R. China.
| | - Qiuping Shen
- School of Animal Husbandry and Veterinary Medicine, Jiangsu Vocational College of Agriculture and Forestry, Jurong 212400, P. R. China.
| |
Collapse
|
2
|
Terzin M, Laffy PW, Robbins S, Yeoh YK, Frade PR, Glasl B, Webster NS, Bourne DG. The road forward to incorporate seawater microbes in predictive reef monitoring. ENVIRONMENTAL MICROBIOME 2024; 19:5. [PMID: 38225668 PMCID: PMC10790441 DOI: 10.1186/s40793-023-00543-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 12/11/2023] [Indexed: 01/17/2024]
Abstract
Marine bacterioplankton underpin the health and function of coral reefs and respond in a rapid and sensitive manner to environmental changes that affect reef ecosystem stability. Numerous meta-omics surveys over recent years have documented persistent associations of opportunistic seawater microbial taxa, and their associated functions, with metrics of environmental stress and poor reef health (e.g. elevated temperature, nutrient loads and macroalgae cover). Through positive feedback mechanisms, disturbance-triggered heterotrophic activity of seawater microbes is hypothesised to drive keystone benthic organisms towards the limit of their resilience and translate into shifts in biogeochemical cycles which influence marine food webs, ultimately affecting entire reef ecosystems. However, despite nearly two decades of work in this space, a major limitation to using seawater microbes in reef monitoring is a lack of a unified and focused approach that would move beyond the indicator discovery phase and towards the development of rapid microbial indicator assays for (near) real-time reef management and decision-making. By reviewing the current state of knowledge, we provide a comprehensive framework (defined as five phases of research and innovation) to catalyse a shift from fundamental to applied research, allowing us to move from descriptive to predictive reef monitoring, and from reactive to proactive reef management.
Collapse
Affiliation(s)
- Marko Terzin
- Australian Institute of Marine Science, PMB no3 Townsville MC, Townsville, QLD, 4810, Australia.
- College of Science and Engineering, James Cook University, Townsville, QLD, 4811, Australia.
- AIMS@JCU, James Cook University, Townsville, QLD, 4811, Australia.
| | - Patrick W Laffy
- Australian Institute of Marine Science, PMB no3 Townsville MC, Townsville, QLD, 4810, Australia
- AIMS@JCU, James Cook University, Townsville, QLD, 4811, Australia
| | - Steven Robbins
- Australian Centre for Ecogenomics, University of Queensland, St. Lucia, QLD, 4072, Australia
| | - Yun Kit Yeoh
- Australian Institute of Marine Science, PMB no3 Townsville MC, Townsville, QLD, 4810, Australia
- AIMS@JCU, James Cook University, Townsville, QLD, 4811, Australia
| | - Pedro R Frade
- Natural History Museum Vienna, 1010, Vienna, Austria
| | - Bettina Glasl
- Division of Microbial Ecology, Centre for Microbiology and Environmental Systems Science, University of Vienna, 1030, Vienna, Austria
| | - Nicole S Webster
- Australian Institute of Marine Science, PMB no3 Townsville MC, Townsville, QLD, 4810, Australia
- Australian Centre for Ecogenomics, University of Queensland, St. Lucia, QLD, 4072, Australia
- Australian Antarctic Program, Department of Climate Change, Energy, the Environment and Water, Kingston, TAS, 7050, Australia
| | - David G Bourne
- Australian Institute of Marine Science, PMB no3 Townsville MC, Townsville, QLD, 4810, Australia.
- College of Science and Engineering, James Cook University, Townsville, QLD, 4811, Australia.
- AIMS@JCU, James Cook University, Townsville, QLD, 4811, Australia.
| |
Collapse
|
3
|
Kumar SS, Ghosh AR. Assessment of bacterial viability: a comprehensive review on recent advances and challenges. Microbiology (Reading) 2019; 165:593-610. [DOI: 10.1099/mic.0.000786] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Affiliation(s)
- Shravanthi S. Kumar
- Department of Integrative Biology, School of Bio Sciences and Technology, Vellore Institute of Technology, Vellore-632014, Tamil Nadu, India
| | - Asit Ranjan Ghosh
- Department of Integrative Biology, School of Bio Sciences and Technology, Vellore Institute of Technology, Vellore-632014, Tamil Nadu, India
| |
Collapse
|
4
|
Chylewska A, Ogryzek M, Makowski M. Modern Approach to Medical Diagnostics - the Use of Separation Techniques in Microorganisms Detection. Curr Med Chem 2019; 26:121-165. [DOI: 10.2174/0929867324666171023164813] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2016] [Revised: 04/20/2017] [Accepted: 05/20/2016] [Indexed: 11/22/2022]
Abstract
Background:Analytical chemistry and biotechnology as an interdisciplinary fields of science have been developed during many years and are experiencing significant growth, to cover a wide range of microorganisms separation techniques and methods, utilized for medical therapeutic and diagnostic purposes. Currently scientific reports contribute by introducing electrophoretical and immunological methods and formation of devices applied in food protection (avoiding epidemiological diseases) and healthcare (safety ensuring in hospitals).Methods:Electrophoretic as well as nucleic-acid-based or specific immunological methods have contributed tremendously to the advance of analyses in recent three decades, particularly in relation to bacteria, viruses and fungi identifications, especially in medical in vitro diagnostics, as well as in environmental or food protection.Results:The paper presents the pathogen detection competitiveness of these methods against conventional ones, which are still too time consuming and also labor intensive. The review is presented in several parts following the current trends in improved pathogens separation and detection methods and their subsequent use in medical diagnosis.Discussion:Part one, consists of elemental knowledge about microorganisms as an introduction to their characterization: descriptions of divisions, sizes, membranes (cells) components. Second section includes the development, new technological and practical solution descriptions used in electrophoretical procedures during microbes analyses, with special attention paid to bio-samples analyses like blood, urine, lymph or wastewater. Third part covers biomolecular areas that have created a basis needed to identify the progress, limitations and challenges of nucleic-acid-based and immunological techniques discussed to emphasize the advantages of new separative techniques in selective fractionating of microorganisms.
Collapse
Affiliation(s)
- Agnieszka Chylewska
- Laboratory of Intermolecular Interactions, Faculty of Chemistry, University of Gdansk, Wita Stwosza 63, 80- 308 Gdansk, Poland
| | - Małgorzata Ogryzek
- Laboratory of Intermolecular Interactions, Faculty of Chemistry, University of Gdansk, Wita Stwosza 63, 80- 308 Gdansk, Poland
| | - Mariusz Makowski
- Laboratory of Intermolecular Interactions, Faculty of Chemistry, University of Gdansk, Wita Stwosza 63, 80- 308 Gdansk, Poland
| |
Collapse
|
5
|
Zimmer-Faust AG, Thulsiraj V, Lee CM, Whitener V, Rugh M, Mendoza-Espinosa L, Jay JA. Multi-tiered approach utilizing microbial source tracking and human associated-IMS/ATP for surveillance of human fecal contamination in Baja California, Mexico. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 640-641:475-484. [PMID: 29864661 DOI: 10.1016/j.scitotenv.2018.05.172] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2018] [Revised: 05/14/2018] [Accepted: 05/14/2018] [Indexed: 06/08/2023]
Abstract
As both the need for reuse of reclaimed wastewater and the burden placed on existing wastewater treatment plants increase, so does the need for methods that can reliably, rapidly and economically identify human-associated contamination. A survey of surface water quality was conducted in Baja California, Mexico where inadequate infrastructure or its inefficient operation leads to poor water quality. The HF183 and Bacteroides thetaiotaomicron (B. theta) human-associated gene markers were detected in 84% and 82% of samples collected during dry weather, illustrating evidence of widespread human fecal contamination. In addition, an inversely-coupled (Inv-IMS/ATP) viability-based assay for detection of B. theta was developed and applied for rapid detection and screening of human-associated fecal contamination. The Inv-IMS/ATP assay was able to effectively differentiate between surface waters impacted with human fecal contamination, and B. theta levels measured by Inv-IMS/ATP were highly correlated with HF183 and B. theta human marker measurements (r = 0.76; r = 0.82) in complex surface water samples. In areas with widespread human fecal contamination and limited access to more expensive methods, a multi-pronged approach utilizing a combination of methods including the Inv-IMS/ATP assay for rapid evaluation and screening of surface water quality alongside human-associated genetic markers may improve risk assessment and surveillance capabilities.
Collapse
Affiliation(s)
- Amity G Zimmer-Faust
- Western Ecology Division, National Health and Environmental Effects Research Laboratory, U.S. Environmental Protection Agency, Currently at Southern California Coastal Water Research Project, Costa Mesa, CA, USA.
| | - Vanessa Thulsiraj
- Biology Department, Mount Saint Mary's University, 12001 Chalon Road, Los Angeles, CA 90049, USA
| | - Christine M Lee
- Earth Science Division, American Association for the Advancement of Science, National Aeronautics and Space Administration Headquarters, WA, USA
| | - Victoria Whitener
- Department of Civil and Environmental Engineering, University of California at Los Angeles, Los Angeles, CA 90095, USA
| | - Megan Rugh
- Department of Civil and Environmental Engineering, University of California at Los Angeles, Los Angeles, CA 90095, USA
| | | | - Jennifer A Jay
- Department of Civil and Environmental Engineering, University of California at Los Angeles, Los Angeles, CA 90095, USA
| |
Collapse
|
6
|
Stationary and portable sequencing-based approaches for tracing wastewater contamination in urban stormwater systems. Sci Rep 2018; 8:11907. [PMID: 30093614 PMCID: PMC6085348 DOI: 10.1038/s41598-018-29920-7] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2017] [Accepted: 07/02/2018] [Indexed: 12/31/2022] Open
Abstract
Urban sewer systems consist of wastewater and stormwater sewers, of which only wastewater is processed before being discharged. Occasionally, misconnections or damages in the network occur, resulting in untreated wastewater entering natural water bodies via the stormwater system. Cultivation of faecal indicator bacteria (e.g. Escherichia coli; E. coli) is the current standard for tracing wastewater contamination. This method is cheap but has limited specificity and mobility. Here, we compared the E. coli culturing approach with two sequencing-based methodologies (Illumina MiSeq 16S rRNA gene amplicon sequencing and Oxford Nanopore MinION shotgun metagenomic sequencing), analysing 73 stormwater samples collected in Stockholm. High correlations were obtained between E. coli culturing counts and frequencies of human gut microbiome amplicon sequences, indicating E. coli is indeed a good indicator of faecal contamination. However, the amplicon data further holds information on contamination source or alternatively how much time has elapsed since the faecal matter has entered the system. Shotgun metagenomic sequencing on a subset of the samples using a portable real-time sequencer, MinION, correlated well with the amplicon sequencing data. This study demonstrates the use of DNA sequencing to detect human faecal contamination in stormwater systems and the potential of tracing faecal contamination directly in the field.
Collapse
|
7
|
Kolm C, Martzy R, Brunner K, Mach RL, Krska R, Heinze G, Sommer R, Reischer GH, Farnleitner AH. A Complementary Isothermal Amplification Method to the U.S. EPA Quantitative Polymerase Chain Reaction Approach for the Detection of Enterococci in Environmental Waters. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2017; 51:7028-7035. [PMID: 28541661 PMCID: PMC5573901 DOI: 10.1021/acs.est.7b01074] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
We report a novel molecular assay, based on helicase-dependent amplification (HDA), for the detection of enterococci as markers for fecal pollution in water. This isothermal assay targets the same Enterococcus 23S rRNA gene region as the existing quantitative polymerase chain reaction (qPCR) assays of U.S. Environmental Protection Agency Methods 1611 and 1609 but can be entirely performed on a simple heating block. The developed Enterococcus HDA assay successfully discriminated 15 enterococcal from 15 non-enterococcal reference strains and reliably detected 48 environmental isolates of enterococci. The limit of detection was 25 target copies per reaction, only 3 times higher than that of qPCR. The applicability of the assay was tested on 30 environmental water sample DNA extracts, simulating a gradient of fecal pollution. Despite the isothermal nature of the reaction, the HDA results were consistent with those of the qPCR reference. Given this performance, we conclude that the developed Enterococcus HDA assay has great potential as a qualitative molecular screening method for resource-limited settings when combined with compatible up- and downstream processes. This amplification strategy can pave the way for developing a new generation of rapid, low-cost, and field-deployable molecular diagnostic tools for water quality monitoring.
Collapse
Affiliation(s)
- Claudia Kolm
- TU
Wien, Institute of Chemical, Environmental
& Biological Engineering, Molecular Diagnostics Group, Department
IFA-Tulln, Konrad-Lorenz-Straße
20, 3430 Tulln, Austria
- ICC
Interuniversity
Cooperation Centre Water & Health, Vienna, Austria (ICC Interuniversity
Cooperation Center Water & Health, Vienna, Austria (www.waterandhealth.at)
| | - Roland Martzy
- TU
Wien, Institute of Chemical, Environmental
& Biological Engineering, Molecular Diagnostics Group, Department
IFA-Tulln, Konrad-Lorenz-Straße
20, 3430 Tulln, Austria
- ICC
Interuniversity
Cooperation Centre Water & Health, Vienna, Austria (ICC Interuniversity
Cooperation Center Water & Health, Vienna, Austria (www.waterandhealth.at)
| | - Kurt Brunner
- TU
Wien, Institute of Chemical, Environmental
& Biological Engineering, Molecular Diagnostics Group, Department
IFA-Tulln, Konrad-Lorenz-Straße
20, 3430 Tulln, Austria
| | - Robert L. Mach
- TU
Wien, Institute of Chemical, Environmental
& Biological Engineering, Research Group of Environmental Microbiology
and Molecular Diagnostics 166/5/4, Gumpendorferstraße 1a, 1060 Vienna, Austria
| | - Rudolf Krska
- University
of Natural Resources and Life Sciences, Vienna (BOKU), Department IFA-Tulln, Center for Analytical Chemistry, Konrad-Lorenz-Straße 20, 3430 Tulln, Austria
| | - Georg Heinze
- Medical
University Vienna, Center for Medical Statistics,
Informatics and Intelligent Systems, Section for Clinical Biometrics, Spitalgasse 23, 1090 Vienna, Austria
| | - Regina Sommer
- Medical
University Vienna, Institute for Hygiene
and Applied Immunology, Water Hygiene, Kinderspitalgasse 15, 1090 Vienna, Austria
- ICC
Interuniversity
Cooperation Centre Water & Health, Vienna, Austria (ICC Interuniversity
Cooperation Center Water & Health, Vienna, Austria (www.waterandhealth.at)
| | - Georg H. Reischer
- TU
Wien, Institute of Chemical, Environmental
& Biological Engineering, Molecular Diagnostics Group, Department
IFA-Tulln, Konrad-Lorenz-Straße
20, 3430 Tulln, Austria
- TU
Wien, Institute of Chemical, Environmental
& Biological Engineering, Research Group of Environmental Microbiology
and Molecular Diagnostics 166/5/4, Gumpendorferstraße 1a, 1060 Vienna, Austria
| | - Andreas H. Farnleitner
- TU
Wien, Institute of Chemical, Environmental
& Biological Engineering, Research Group of Environmental Microbiology
and Molecular Diagnostics 166/5/4, Gumpendorferstraße 1a, 1060 Vienna, Austria
- Karl Landsteiner
University of Health Sciences, Research Unit Water Quality and Health, Dr.-Karl-Dorrek-Straße 30, 3500 Krems, Austria
- ICC
Interuniversity
Cooperation Centre Water & Health, Vienna, Austria (ICC Interuniversity
Cooperation Center Water & Health, Vienna, Austria (www.waterandhealth.at)
- Telephone: +43-664-605882244. E-mail:
| |
Collapse
|
8
|
Highly efficient and specific separation of Staphylococcus aureus from lettuce and milk using Dynabeads protein G conjugates. Food Sci Biotechnol 2016; 25:1501-1505. [PMID: 30263437 DOI: 10.1007/s10068-016-0233-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2016] [Revised: 06/28/2016] [Accepted: 06/28/2016] [Indexed: 01/06/2023] Open
Abstract
An immunomagnetic separation method using antibody-coated Dynabeads® Protein G was developed for specific and efficient separation of Staphylococcus aureus in lettuce and whole milk. The amount of immunomagnetic beads (IMBs) and conjugation conditions were optimized. A high capture efficiency was obtained with 0.4 mg of IMBs, an immunoreaction time of 20 min, and a separation time of 1 min without wash. Under optimal conditions, the capture efficiency (CE) for 100-105 CFU/mL of S. aureus was higher than 91.46%. The IMBs showed high specificity even with a high constant number (107 CFU/mL) of Bacillus cereus, Micrococcus luteus, and Lactobacillus plantarum. The CE of IMBs against S. aureus at concentrations from 102 to 105 CFU/mL ranged from 78.70 to 94.77% for lettuce and 60.0 to 73.27% for milk samples. This IMS can be an appropriate selection for combining with bacterial detection method or efficient isolation procedure for S. aureus from foods.
Collapse
|
9
|
Wang Z, Wang D, Chen J, Sela DA, Nugen SR. Development of a novel bacteriophage based biomagnetic separation method as an aid for sensitive detection of viable Escherichia coli. Analyst 2015; 141:1009-16. [PMID: 26689710 DOI: 10.1039/c5an01769f] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
The application of bacteriophage combined with the use of magnetic separation techniques has emerged as a valuable tool for the sensitive identification and detection of bacteria. In this study, bacteriophage T7 labelled magnetic beads were developed for the detection of viable bacterial cells. Fusion of the biotin acceptor peptide (BAP) with the phage capsid protein gene and the insertion of the biotin ligase (BirA) gene enabled the display of the BAP ligand and the expression protein BirA during the replication cycle of phage infection. The replicated Escherichia coli specific bacteriophage was biotinylated in vivo and coated on magnetic beads via streptavidin-biotin interaction. Immobilization efficiency of the recombinant phage was investigated on magnetic beads and the phage-bead complex was evaluated by detecting E. coli from inoculated broth. When compared to the wild type phage, the recombinant phage T7birA-bap had a high immobilization density on streptavidin-coated magnetic beads and could capture 86.2% of E. coli cells from broth within 20 min. As this phage-based biomagnetic detection approach provided a low detection limit of 10(2) CFU mL(-1) without pre-enrichment, we believe this assay could be further developed to detect other bacteria of interest by applying host-specific phages. This would be of particular use in detecting bacteria which are difficult to grow or replicate slowly in culture.
Collapse
Affiliation(s)
- Ziyuan Wang
- University of Massachusetts, 246 Chenoweth, 102 Holdsworth Way, Amherst, MA, USA.
| | | | | | | | | |
Collapse
|
10
|
Performance and specificity of the covalently linked immunomagnetic separation-ATP method for rapid detection and enumeration of enterococci in coastal environments. Appl Environ Microbiol 2014; 80:2705-14. [PMID: 24561583 DOI: 10.1128/aem.04096-13] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The performance and specificity of the covalently linked immunomagnetic separation-ATP (Cov-IMS/ATP) method for the detection and enumeration of enterococci was evaluated in recreational waters. Cov-IMS/ATP performance was compared with standard methods: defined substrate technology (Enterolert; IDEXX Laboratories), membrane filtration (EPA Method 1600), and an Enterococcus-specific quantitative PCR (qPCR) assay (EPA Method A). We extend previous studies by (i) analyzing the stability of the relationship between the Cov-IMS/ATP method and culture-based methods at different field sites, (ii) evaluating specificity of the assay for seven ATCC Enterococcus species, (iii) identifying cross-reacting organisms binding the antibody-bead complexes with 16S rRNA gene sequencing and evaluating specificity of the assay to five nonenterococcus species, and (iv) conducting preliminary tests of preabsorption as a means of improving the assay. Cov-IMS/ATP was found to perform consistently and with strong agreement rates (based on exceedance/compliance with regulatory limits) of between 83% and 100% compared to the culture-based Enterolert method at a variety of sites with complex inputs. The Cov-IMS/ATP method is specific to five of seven different Enterococcus spp. tested. However, there is potential for nontarget bacteria to bind the antibody, which may be reduced by purification of the IgG serum with preabsorption at problematic sites. The findings of this study help to validate the Cov-IMS/ATP method, suggesting a predictable relationship between the Cov-IMS/ATP method and traditional culture-based methods, which will allow for more widespread application of this rapid and field-portable method for coastal water quality assessment.
Collapse
|
11
|
Agidi S, Vedachalam S, Mancl K, Lee J. Effectiveness of onsite wastewater reuse system in reducing bacterial contaminants measured with human-specific IMS/ATP and qPCR. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2013; 115:167-174. [PMID: 23254156 DOI: 10.1016/j.jenvman.2012.11.021] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2012] [Revised: 11/08/2012] [Accepted: 11/13/2012] [Indexed: 06/01/2023]
Abstract
Water shortages and the drive to recycle is increasing interest in reuse of reclaimed wastewater. Timely and cost-effective ways to detect fecal pollutants prior to reuse increases confidence of residents and neighbors concerned about reuse of reclaimed wastewater. The on-site wastewater treatment and reuse systems (OWTRS) used in this study include a septic tank, peat bioreactor, ClO(2) disinfection and land spray irrigation system. Bacteroides fragilis, Escherichia coli and Enterococcus spp., were tested with immunomagnetic separation/ATP bioluminescence (IMS/ATP), qPCR and culture-based methods. The results displayed a 2-log reduction in fecal bacteria in the peat bioreactor and a 5-log reduction following chloride dioxide disinfection. The fecal bacteria levels measured by IMS/ATP correlated with qPCR results: HuBac 16S (R(2) = 0.903), Bf-group 16S (R(2) = 0.956), gyrB (R(2) = 0.673), and Ent 23S (R(2) = 0.724). This is the first study in which the newly developed human-specific IMS/ATP and previously developed IMS/ATP were applied for determining OWTRS efficiency. Results of the study revealed that IMS/ATP is a timely and cost-effective way to detect fecal contaminants, and results were validated with qPCR and culture based methods. The new IMS/ATP can also be applied broadly in the detection of human-originated fecal contamination.
Collapse
Affiliation(s)
- Senyo Agidi
- College of Public Health, Division of Environmental Health Science, The Ohio State University, OH 43210, USA
| | | | | | | |
Collapse
|
12
|
An IMS/ATP Assay for the Detection of Mycobacterium tuberculosis in Urine. Tuberc Res Treat 2012; 2012:292605. [PMID: 22655193 PMCID: PMC3357591 DOI: 10.1155/2012/292605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2011] [Revised: 02/15/2012] [Accepted: 02/18/2012] [Indexed: 11/18/2022] Open
Abstract
Background. Although sputum smears are the gold standard for diagnosis of tuberculosis, sensitivity in HIV/TB coinfection cases is low, indicating a need for alternative methods. Urine is being increasingly evaluated. Materials and Methods. A novel method for detecting Mycobacterium tuberculosis (MTB) in synthetic urine using a combined IMS/ATP assay was evaluated. Preliminary work established standard ATP conditions and the sensitivity and specificity of the MTB antibody. Eighty-four blinded samples in four replicate assays were evaluated for the presence of MTB using labeled immunomagnetic beads for capture. Beads were separated, washed, and resuspended in broth and added to a microtiter plate. Bioluminescent output was measured and signal-to-noise ratios were calculated. All samples were plated on Middlebrook 7H10 agar or trypticase soy agar to determine limit of detection and recoveries. Results and Conclusions. MTB was distinguished from common bacteriuria isolates and other nontarget bacteria by its ATP results. IMS/ATP successfully detected 19 of 28 samples of MTB in synthetic urine with a limit of detection of 104 CFU/ml. Sensitivity and specificity were 67.9% and 82.1%, respectively. This assay offers a possible rapid screening method for HIV-positive patients with suspected coinfection to improve MTB diagnosis.
Collapse
|
13
|
Colford JM, Schiff KC, Griffith JF, Yau V, Arnold BF, Wright CC, Gruber JS, Wade TJ, Burns S, Hayes J, McGee C, Gold M, Cao Y, Noble RT, Haugland R, Weisberg SB. Using rapid indicators for Enterococcus to assess the risk of illness after exposure to urban runoff contaminated marine water. WATER RESEARCH 2012; 46:2176-86. [PMID: 22356828 PMCID: PMC3354759 DOI: 10.1016/j.watres.2012.01.033] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2011] [Revised: 01/24/2012] [Accepted: 01/25/2012] [Indexed: 05/03/2023]
Abstract
BACKGROUND Traditional fecal indicator bacteria (FIB) measurement is too slow (>18 h) for timely swimmer warnings. OBJECTIVES Assess relationship of rapid indicator methods (qPCR) to illness at a marine beach impacted by urban runoff. METHODS We measured baseline and two-week health in 9525 individuals visiting Doheny Beach 2007-08. Illness rates were compared (swimmers vs. non-swimmers). FIB measured by traditional (Enterococcus spp. by EPA Method 1600 or Enterolert™, fecal coliforms, total coliforms) and three rapid qPCR assays for Enterococcus spp. (Taqman, Scorpion-1, Scorpion-2) were compared to health. Primary bacterial source was a creek flowing untreated into ocean; the creek did not reach the ocean when a sand berm formed. This provided a natural experiment for examining FIB-health relationships under varying conditions. RESULTS We observed significant increases in diarrhea (OR 1.90, 95% CI 1.29-2.80 for swallowing water) and other outcomes in swimmers compared to non-swimmers. Exposure (body immersion, head immersion, swallowed water) was associated with increasing risk of gastrointestinal illness (GI). Daily GI incidence patterns were different: swimmers (2-day peak) and non-swimmers (no peak). With berm-open, we observed associations between GI and traditional and rapid methods for Enterococcus; fewer associations occurred when berm status was not considered. CONCLUSIONS We found increased risk of GI at this urban runoff beach. When FIB source flowed freely (berm-open), several traditional and rapid indicators were related to illness. When FIB source was weak (berm-closed) fewer illness associations were seen. These different relationships under different conditions at a single beach demonstrate the difficulties using these indicators to predict health risk.
Collapse
Affiliation(s)
- John M Colford
- University of California Berkeley, School of Public Health, 101 Haviland, MC# 7358, Berkeley, CA 94720-7358, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Dead-end ultrafiltration concentration and IMS/ATP-bioluminescence detection of Escherichia coli O157:H7 in recreational water and produce wash. J Microbiol Methods 2011; 87:338-42. [PMID: 21986030 DOI: 10.1016/j.mimet.2011.09.010] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2011] [Revised: 09/21/2011] [Accepted: 09/23/2011] [Indexed: 01/24/2023]
Abstract
The purpose of this study was to develop a detection method for viable E. coli O157:H7 in fresh produce and recreational water. The method was evaluated using eight samples of produce wash and recreational water with or without spiked E. coli O157:H7 at ≤10(2) CFU·ml(-1) and concentrated using dead-end ultrafiltration (DEUF) to produce primary and secondary retentates. Fifty-four matrix replicates of undiluted secondary retentates or dilutions (1:2 or 1:10 in buffer) were evaluated using an IMS/ATP bioluminescence assay (IMS/ATP). Combining primary and secondary DEUF yielded a 2-4 log(10) increase in E. coli O157:H7 concentrations in spiked samples and resulted in signal-to-noise ratios 2-219 fold higher than controls, depending on the sample type. DEUF increased the concentration of E. coli O157:H7 to within the detectable limits of IMS/ATP. The combined assay provided detection of viable E. coli O157:H7 in produce and recreational water. Accurate detection of microbial pathogens using DEUF and IMS/ATP could reduce disease outbreaks from contaminated water sources and food products.
Collapse
|
15
|
Use of immunomagnetic separation for the detection of Desulfovibrio vulgaris from environmental samples. J Microbiol Methods 2011; 86:204-9. [DOI: 10.1016/j.mimet.2011.05.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2011] [Revised: 05/04/2011] [Accepted: 05/06/2011] [Indexed: 11/21/2022]
|
16
|
Comparison of rapid quantitative PCR-based and conventional culture-based methods for enumeration of Enterococcus spp. and Escherichia coli in recreational waters. Appl Environ Microbiol 2010; 76:7437-43. [PMID: 20870786 DOI: 10.1128/aem.00651-10] [Citation(s) in RCA: 94] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Recreational water quality is currently monitored using culture-based methods that require 18 to 96 h for results. Quantitative PCR (QPCR) methods that can be completed in less than 2 h have been developed, but they could yield different results than the conventional methods. We present two studies in which samples were processed simultaneously for Enterococcus spp. and Escherichia coli using two culture-based methods (EPA method 1600 and Enterolert/Colilert-18) and QPCR. The proprietary QPCR assays targeted the 23S rRNA (Enterococcus spp.) and uidA (E. coli) genes and were conducted using lyophilized beads containing all reagents. In the first study, the QPCR method developers processed 54 blind samples that were inoculated with sewage or pure cultures or were ambient beach samples. The second study involved 163 samples processed by water quality personnel. The correlation between results of QPCR and EPA 1600 during the first study (r²) was 0.69 for Enterococcus spp., which was less than that observed between the culture-based methods (r², 0.87). During the second study, the correlations were similar. No false positives occurred in either study when QPCR-based assays were used with blank samples. Levels of reproducibility measured through coefficients of variation were similar for results by Enterococcus QPCR and culture-based methods during both studies but were higher for E. coli QPCR results in the first study. Regarding the concentration at which beach management decisions are issued in the State of California, the agreement between results of Enterococcus QPCR and EPA method 1600 was 88%, compared to 94% agreement between EPA method 1600 and Enterolert. The beach management decision agreement between E. coli QPCR and Colilert-18 was 94%. The samples showing disagreement suggested an underestimation bias for QPCR.
Collapse
|
17
|
Mudanyali O, Oztoprak C, Tseng D, Erlinger A, Ozcan A. Detection of waterborne parasites using field-portable and cost-effective lensfree microscopy. LAB ON A CHIP 2010; 10:2419-23. [PMID: 20694255 PMCID: PMC2942761 DOI: 10.1039/c004829a] [Citation(s) in RCA: 80] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Protection of human health and well-being through water quality management is an important goal for both the developed and the developing parts of the world. In the meantime, insufficient disinfection techniques still fail to eliminate pathogenic contaminants in freshwater as well as recreational water resources. Therefore, there is a significant need for screening of water quality to prevent waterborne outbreaks and incidents of water-related diseases. Toward this end, here we investigate the use of a field-portable and cost-effective lensfree holographic microscope to image and detect pathogenic protozoan parasites such as Giardia Lamblia and Cryptosporidium Parvum at low concentration levels. This compact lensless microscope (O. Mudanyali et al., Lab Chip, 2010, 10, 1417-1428), weighing approximately 46 grams, achieves a numerical aperture of approximately 0.1-0.2 over an imaging field of view that is more than an order of magnitude larger than a typical 10X objective lens, and therefore may provide an important high-throughput analysis tool for combating waterborne diseases especially in resource limited settings.
Collapse
Affiliation(s)
| | | | - Derek Tseng
- Electrical Engineering Department, UCLA, CA, 90095, USA
| | | | - Aydogan Ozcan
- Electrical Engineering Department, UCLA, CA, 90095, USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA, 90095, USA
| |
Collapse
|
18
|
Pappert G, Rieger M, Niessner R, Seidel M. Immunomagnetic nanoparticle-based sandwich chemiluminescence-ELISA for the enrichment and quantification of E. coli. Mikrochim Acta 2009. [DOI: 10.1007/s00604-009-0264-x] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
19
|
Lee CM, Griffith JF, Kaiser W, Jay JA. Covalently linked immunomagnetic separation/adenosine triphosphate technique (Cov-IMS/ATP) enables rapid, in-field detection and quantification of Escherichia coli and Enterococcus spp. in freshwater and marine environments. J Appl Microbiol 2009; 109:324-33. [PMID: 20102424 DOI: 10.1111/j.1365-2672.2009.04660.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
AIMS Developing a rapid method for detection of faecal pollution is among the critical goals set forth by the Environmental Protection Agency in its revision of water quality criteria. The purpose of this study is to devise and test covalently linked antibody-bead complexes for faecal indicator bacteria (FIB), specifically Escherichia coli or Enterococcus spp., in measuring water quality in freshwater and marine systems. METHODS AND RESULTS Covalently linked complexes were 58-89% more robust than antibody-bead complexes used in previous studies. Freshwater and marine water samples analysed using covalently linked immunomagnetic separation/adenosine triphosphate quantification technique (Cov-IMS/ATP) and culture-based methods yielded good correlations for E. coli (R = 0·87) and Enterococcus spp. (R = 0·94), with method detection limits below EPA recreational water quality health standards for single standard exceedances (E. coli- 38 cells per 100 ml; Enterococcus spp. - 25 cells per 100 ml). Cov-IMS/ATP correctly classified 87% of E. coli and 94% of Enterococcus spp. samples based on these water quality standards. Cov-IMS/ATP was also used as a field method to rapidly distinguish differential loading of E. coli between two stream channels to their confluence. CONCLUSIONS Cov-IMS/ATP is a robust, in-field detection method for determining water quality of both fresh and marine water systems as well as differential loading of FIB from two converging channels. SIGNIFICANCE AND IMPACT OF THE STUDY To our knowledge, this is the first work to present a viable rapid, in-field assay for measuring FIB concentrations in marine water environments. Cov-IMS/ATP is a potential alternative detection method, particularly in areas with limited laboratory support and resources, because of its increased economy and portability.
Collapse
Affiliation(s)
- C M Lee
- UCLA Civil and Environmental Engineering, Los Angeles, CA 90095-1593, USA
| | | | | | | |
Collapse
|
20
|
Griffith JF, Cao Y, McGee CD, Weisberg SB. Evaluation of rapid methods and novel indicators for assessing microbiological beach water quality. WATER RESEARCH 2009; 43:4900-7. [PMID: 19800095 DOI: 10.1016/j.watres.2009.09.017] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2009] [Revised: 08/24/2009] [Accepted: 09/07/2009] [Indexed: 05/11/2023]
Abstract
A broad suite of new measurement methods and indicators based on molecular measurement technology have been developed to assess beach water quality, but they have generally been subjected to limited testing outside of the laboratory in which they were developed. Here we evaluated 29 assays targeting a variety of bacterial, viral, and chemical analytes by providing the method developers with twelve blind samples consisting of samples spiked with known concentration of sewage or gull guano and negative controls. Each method was evaluated with respect to its ability to detect the target organism, absence of signal in the negative controls and repeatability among replicates. Only six of the 30 methods detected their targets in at least 75% of the samples while consistently determining the absence of the target in the negative controls. Among quantitative methods, QPCR for Bacteroides thetaiotamicron and Enterococcus detected by Luminex reliably identified all but one sample containing human fecal material and produced no false positive results. Among non-quantitative methods, the Enterococcus esp gene, the Bacteroidales human specific marker and culture-based coliphage were the most reliable for identifying human fecal material. We also found that investigator-specific variations of methods targeting the same organism often produced different results.
Collapse
Affiliation(s)
- John F Griffith
- Southern California Coastal Water Research Project, Costa Mesa, CA 92626, United States.
| | | | | | | |
Collapse
|
21
|
Bushon RN, Likirdopulos CA, Brady AMG. Comparison of immunomagnetic separation/adenosine triphosphate rapid method to traditional culture-based method for E. coli and enterococci enumeration in wastewater. WATER RESEARCH 2009; 43:4940-4946. [PMID: 19628248 DOI: 10.1016/j.watres.2009.06.047] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2009] [Revised: 06/16/2009] [Accepted: 06/22/2009] [Indexed: 05/28/2023]
Abstract
Untreated wastewater samples from California, North Carolina, and Ohio were analyzed by the immunomagnetic separation/adenosine triphosphate (IMS/ATP) method and the traditional culture-based method for E. coli and enterococci concentrations. The IMS/ATP method concentrates target bacteria by immunomagnetic separation and then quantifies captured bacteria by measuring bioluminescence induced by release of ATP from the bacterial cells. Results from this method are available within 1h from the start of sample processing. Significant linear correlations were found between the IMS/ATP results and results from traditional culture-based methods for E. coli and enterococci enumeration for one location in California, two locations in North Carolina, and one location in Ohio (r values ranged from 0.87 to 0.97). No significant linear relation was found for a second location in California that treats a complex mixture of residential and industrial wastewater. With the exception of one location, IMS/ATP showed promise as a rapid method for the quantification of faecal-indicator organisms in wastewater.
Collapse
Affiliation(s)
- Rebecca N Bushon
- US Geological Survey, 6480 Doubletree Avenue, Columbus, OH 43229-1111, USA.
| | | | | |
Collapse
|