1
|
Sánchez-Guzmán MDJ, Loyola-Cruz MÁ, López-Ornelas A, Cruz-Cruz C, Durán-Manuel EM, Bello-López JM. In situ and in vitro evaluation of two antiseptics for blood bank based on chlorhexidine gluconate/isopropyl alcohol and povidone-iodine. Transfus Apher Sci 2024; 63:103854. [PMID: 38061923 DOI: 10.1016/j.transci.2023.103854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 11/03/2023] [Accepted: 11/22/2023] [Indexed: 03/10/2024]
Abstract
BACKGROUND Poor disinfection is the main cause of blood contamination, so its elimination is key to limiting the entry of bacteria into the collection system. With the advancement of antiseptic technology, antiseptics with sterile, disposable applicators are now available. AIM To evaluate in situ two antiseptics (with and without applicators) for blood banks and to demonstrate in vitro antiseptic activity on bacterial biofilms of importance in transfusion medicine. METHODS Antiseptic A (2% sterile solution of chlorhexidine gluconate/70% isopropyl alcohol provided with applicator) and bulk antiseptic B (10% povidone-iodine) were evaluated. The deferred blood donor arms were subjected to disinfection with antiseptics A and B and the contralateral arms were cultured to determine the baseline bacterial load (control). Antiseptic activity was assessed by ANOVA and logaritmic reduction values (LRV) and percentage reduction values (PRV) were calculated. Finally, the in vitro activity of antiseptic A was analyzed by confocal laser scanning microscopy (CLSM) on biofilm models. RESULTS Prior to disinfection tests, commensal and clinically important bacteria were identified; antiseptic A showed post-disinfection bacterial growth rates of zero compared to controls (p < 0.0001). The frequency of bacterial growth with antiseptic B was 74%. A significant difference was identified between both antiseptics, where antiseptic A showed higher activity (p < 0.5468). LRV and PRV were 0.6-2.5/100% and 0.3-1.7/66.7-99.7% for antiseptics A and B, respectively. Through CLSM, disinfectant A (without applicator) showed lower in vitro antiseptic activity on the tested biofilms at the exposure times recommended by the manufacturer. CONCLUSIONS Sterile solution of chlorhexidine gluconate/isopropyl alcohol with applicator showed advantages disinfection in deferred blood donors over povidone-iodine.
Collapse
Affiliation(s)
- María de Jesús Sánchez-Guzmán
- División de Investigación, Hospital Juárez de México, Mexico City, Mexico; Sección de Estudios de Posgrado e Investigación, Escuela Superior de Medicina, Mexico City, Mexico
| | | | | | - Clemente Cruz-Cruz
- División de Investigación, Hospital Juárez de México, Mexico City, Mexico; Sección de Estudios de Posgrado e Investigación, Escuela Superior de Medicina, Mexico City, Mexico
| | - Emilio Mariano Durán-Manuel
- División de Investigación, Hospital Juárez de México, Mexico City, Mexico; Sección de Estudios de Posgrado e Investigación, Escuela Superior de Medicina, Mexico City, Mexico
| | | |
Collapse
|
2
|
O’Flaherty N, Bryce L, Nolan J, Lambert M. Changing Strategies for the Detection of Bacteria in Platelet Components in Ireland: From Primary and Secondary Culture (2010-2020) to Large Volume Delayed Sampling (2020-2023). Microorganisms 2023; 11:2765. [PMID: 38004776 PMCID: PMC10673373 DOI: 10.3390/microorganisms11112765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 11/07/2023] [Accepted: 11/07/2023] [Indexed: 11/26/2023] Open
Abstract
Bacterial contamination of platelet components (PC) poses the greatest microbial risk to recipients, as bacteria can multiply over the course of PC storage at room temperature. Between 2010 and 2020, the Irish Blood Transfusion Service (IBTS) screened over 170,000 buffy coat-derived pooled (BCDP) and single-donor apheresis platelets (SDAPs) with the BACT/ALERT 3D microbial detection system (Biomerieux, L'Etoile, France), using a two-step screening protocol which incorporated primary and secondary cultures. Although the protocol was successful in averting septic transfusion reactions (STRs), testing large sample volumes at later time points was reported to improve detection of bacterial contamination. A modified large-volume delayed sampling (LVDS)-type protocol was adopted in 2020, which in the case of SDAP was applied to collections rather than individual splits (2020-2023, 44,642 PC screened). Rates of bacterial contamination for BCDP were 0.125% on Day-2, 0.043% on Day-4 vs. 0.191% in the post-LVDS period. SDAP contamination rates in the pre-LVDS period were 0.065% on Day-1, 0.017% on Day-4 vs. 0.072% in the post-LVDS period. Confirmed STRs were absent, and the interdiction rate for possibly contaminated SDAP was over 70%. In the post-LVDS period, BCDPs had a higher total positivity rate than SDAPs, 0.191% (1:525) versus 0.072% (1:1385), respectively, (chi-squared 12.124, 1 df, p = 0.0005). The majority of organisms detected were skin-flora-type, low pathogenicity organisms, including coagulase-negative staphylococci and Cutibacterium acnes, with little change in the frequency of clinically significant organisms identified over time. Both protocols prevented the issue of potentially harmful components contaminated (rarely) with a range of pathogenic bacteria, including Escherichia coli, Serratia marcesens, Staphylococcus aureus, and streptococci. Culture positivity of outdates post-LVDS whereby 100% of expired platelets are retested provides a residual risk estimate of 0.06% (95% CI 0.016-0.150). However, bacterial contamination rates in expired platelets did not demonstrate a statistically significant difference between the pre-LVDS 0.100% (CI 0.033-0.234) and post-LVDS 0.059% (0.016-0.150) periods (chi-squared = 0.651, 1 df, p = 0.42).
Collapse
Affiliation(s)
- Niamh O’Flaherty
- Irish Blood Transfusion Service, National Blood Centre, D08 NH5R Dublin, Ireland; (L.B.); (M.L.)
| | | | | | | |
Collapse
|
3
|
Cheng A, Das A, Chaw K, Dennington PM, Styles CE, Gosbell IB. Safety Analysis of Extended Platelet Shelf-Life with Large-Volume Delayed Sampling on BACT/ALERT ® VIRTUO ® in Australia. Microorganisms 2023; 11:2346. [PMID: 37764190 PMCID: PMC10535894 DOI: 10.3390/microorganisms11092346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 09/11/2023] [Accepted: 09/14/2023] [Indexed: 09/29/2023] Open
Abstract
Transfusion-transmitted bacterial infection (TTBI) is the leading cause of transfusion-transmitted infections. Platelet components are more likely to be associated with bacterial contamination due to their storage requirements. Australian Red Cross Lifeblood introduced the bacterial contamination screening (BCS) of all platelet components in 2008. The process was recently updated with the use of BACT/ALERT® VIRTUO®, a large-volume delayed sampling (LVDS) protocol and extending platelet shelf-life to seven days. This article describes the results from the routine BCS of platelet components in Australia. Use of VIRTUO has resulted in lower false-positive rates, reducing wastage and improving platelet inventory. Our findings show that the combination of LVDS and VIRTUO improves the safety of platelet transfusions through earlier time to detection, especially for pathogenic bacterial species. Pathogenic bacteria grew within 24 h of incubation with a clear delineation between pathogenic and non-pathogenic species. The data show this protocol is very safe, with no TTBI cases during this time. There were no TTBI reports in recipients of platelet components that subsequently had a positive culture with Cutibacterium species, probably due to the low pathogenic potential of these organisms and slow replication in aerobic platelet bags. We conclude there is no advantage in incubating culture bottles beyond five days.
Collapse
Affiliation(s)
- Anthea Cheng
- Donor and Product Safety Policy Unit, Australian Red Cross Lifeblood, West Melbourne, VIC 3003, Australia
| | - Anindita Das
- Donor and Product Safety Policy Unit, Australian Red Cross Lifeblood, West Melbourne, VIC 3003, Australia
- Clinical Microbiology, ACT Pathology, Garran, ACT 2606, Australia
- Faculty of Health, University of Canberra, Bruce, ACT 2617, Australia
| | - Khin Chaw
- Donor and Product Safety Policy Unit, Australian Red Cross Lifeblood, West Melbourne, VIC 3003, Australia
- MetroSouth Public Health Unit, Eight Mile Plains, QLD 4113, Australia
| | - Peta M Dennington
- Pathology Services, Australian Red Cross Lifeblood, Alexandria, NSW 2015, Australia
| | - Claire E Styles
- Donor and Product Safety Policy Unit, Australian Red Cross Lifeblood, West Melbourne, VIC 3003, Australia
| | - Iain B Gosbell
- Donor and Product Safety Policy Unit, Australian Red Cross Lifeblood, West Melbourne, VIC 3003, Australia
- School of Medicine, Western Sydney University, Penrith, NSW 2747, Australia
| |
Collapse
|
4
|
Arghittu A, Dettori M, Deriu GM, Soddu S, Manca PC, Carboni AA, Collu I, Palmieri A, Deiana G, Azara A, Castiglia P, Masia MD. Controlling Infectious Risk in Transfusion: Assessing the Effectiveness of Skin Disinfection in Blood Donors. Healthcare (Basel) 2022; 10:healthcare10050845. [PMID: 35627982 PMCID: PMC9141022 DOI: 10.3390/healthcare10050845] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 04/22/2022] [Accepted: 05/02/2022] [Indexed: 02/01/2023] Open
Abstract
Bacterial infectious risk is a major problem in transfusion medicine. The type of micro-organisms isolated during bacterial contamination of blood products indicates that the donor’s skin is its main source. In this context, the primary measures to reduce this risk are: (a) optimal disinfection of the donor’s arm and (b) satellite bag diversion of the initial volume of blood collected. This work aimed to verify the effectiveness of skin disinfection of the blood donor’s venipuncture site. Two methodological approaches were used: (a) qualitative and quantitative microbiological testing of the skin at the collection site, before and post-disinfection; (b) qualitative microbiological testing of the first deviated blood. Pre-disinfection testing showed skin microbial load values between 3 and >200 CFU/plate. More than two-thirds of the isolates were Gram-positive bacteria (77.8%) of which 57.7% were staphylococci. Among Gram-negative bacteria, Pseudomonadaceae, Enterobacteriaceae, and Acinetobacter spp. were isolated from the blood donors (BDs). Post-disinfection, a 100% reduction in microbial load was observed in 84.4% of BDs. Microbiological testing of the first blood diverted sample revealed the presence of microbial flora in 1.9% samples; of the isolates, 83.3% were non-aureus staphylococci. This study highlights the importance of the correct application of skin disinfection procedures in order to ensure blood safety.
Collapse
Affiliation(s)
- Antonella Arghittu
- Department of Biomedical Sciences, University of Sassari, 07100 Sassari, Italy; (A.A.); (I.C.); (G.D.)
- University Hospital of Sassari, 07100 Sassari, Italy; (G.M.D.); (S.S.); (P.C.M.); (A.A.C.); (A.P.); (A.A.); (P.C.)
| | - Marco Dettori
- University Hospital of Sassari, 07100 Sassari, Italy; (G.M.D.); (S.S.); (P.C.M.); (A.A.C.); (A.P.); (A.A.); (P.C.)
- Department of Medical, Surgical and Experimental Sciences, University of Sassari, 07100 Sassari, Italy;
- Correspondence:
| | - Grazia Maria Deriu
- University Hospital of Sassari, 07100 Sassari, Italy; (G.M.D.); (S.S.); (P.C.M.); (A.A.C.); (A.P.); (A.A.); (P.C.)
| | - Serena Soddu
- University Hospital of Sassari, 07100 Sassari, Italy; (G.M.D.); (S.S.); (P.C.M.); (A.A.C.); (A.P.); (A.A.); (P.C.)
| | - Pietro Carmelo Manca
- University Hospital of Sassari, 07100 Sassari, Italy; (G.M.D.); (S.S.); (P.C.M.); (A.A.C.); (A.P.); (A.A.); (P.C.)
| | - Anna Angela Carboni
- University Hospital of Sassari, 07100 Sassari, Italy; (G.M.D.); (S.S.); (P.C.M.); (A.A.C.); (A.P.); (A.A.); (P.C.)
| | - Irene Collu
- Department of Biomedical Sciences, University of Sassari, 07100 Sassari, Italy; (A.A.); (I.C.); (G.D.)
| | - Alessandra Palmieri
- University Hospital of Sassari, 07100 Sassari, Italy; (G.M.D.); (S.S.); (P.C.M.); (A.A.C.); (A.P.); (A.A.); (P.C.)
- Department of Medical, Surgical and Experimental Sciences, University of Sassari, 07100 Sassari, Italy;
| | - Giovanna Deiana
- Department of Biomedical Sciences, University of Sassari, 07100 Sassari, Italy; (A.A.); (I.C.); (G.D.)
- University Hospital of Sassari, 07100 Sassari, Italy; (G.M.D.); (S.S.); (P.C.M.); (A.A.C.); (A.P.); (A.A.); (P.C.)
| | - Antonio Azara
- University Hospital of Sassari, 07100 Sassari, Italy; (G.M.D.); (S.S.); (P.C.M.); (A.A.C.); (A.P.); (A.A.); (P.C.)
- Department of Medical, Surgical and Experimental Sciences, University of Sassari, 07100 Sassari, Italy;
| | - Paolo Castiglia
- University Hospital of Sassari, 07100 Sassari, Italy; (G.M.D.); (S.S.); (P.C.M.); (A.A.C.); (A.P.); (A.A.); (P.C.)
- Department of Medical, Surgical and Experimental Sciences, University of Sassari, 07100 Sassari, Italy;
| | - Maria Dolores Masia
- Department of Medical, Surgical and Experimental Sciences, University of Sassari, 07100 Sassari, Italy;
| |
Collapse
|
5
|
Aplin K, Pitt T, Allen J, Roy A, Tidey K, Ball J, McDonald CP. Extending the 30‐minute rule for red cell units – investigation of the bacterial risk of 60‐minute exposures to ambient temperature. Vox Sang 2019; 114:189-197. [DOI: 10.1111/vox.12747] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Revised: 11/22/2018] [Accepted: 12/13/2018] [Indexed: 01/03/2023]
Affiliation(s)
- Kate Aplin
- National Bacteriology Laboratory NHS Blood and Transplant London UK
| | - Tyrone Pitt
- National Bacteriology Laboratory NHS Blood and Transplant London UK
| | - Jennifer Allen
- National Bacteriology Laboratory NHS Blood and Transplant London UK
| | - Anjana Roy
- National Bacteriology Laboratory NHS Blood and Transplant London UK
| | - Katrina Tidey
- National Bacteriology Laboratory NHS Blood and Transplant London UK
| | - Joanne Ball
- National Bacteriology Laboratory NHS Blood and Transplant London UK
| | | |
Collapse
|
6
|
Viana JD, Ferreira SC, Matana SR, Rossi F, Patel P, Garson JA, Rocha V, Tedder R, Mendrone-Júnior A, Levi JE. Detection of bacterial contamination in platelet concentrates from Brazilian donors by molecular amplification of the ribosomal 16S gene. Transfus Med 2018; 28:420-426. [PMID: 30304760 DOI: 10.1111/tme.12561] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2018] [Revised: 08/09/2018] [Accepted: 09/12/2018] [Indexed: 11/30/2022]
Abstract
OBJECTIVE The aim of our work was to establish a semi-automated high-throughput DNA amplification method for the universal screening of bacteria in platelet concentrates (PCs). BACKGROUND Among cases of transfusion transmission of infectious agents, bacterial contamination ranks first in the number of events, morbidity and mortality. Transmission occurs mainly by transfused PCs. Automated culture is adopted by some blood banks for screening of bacterial contamination, but this procedure is expensive and has a relatively long turnaround time. METHODS PCs were spiked with suspensions of five different bacterial species in a final concentration of 1 and 10 colony-forming units (CFU) per millilitre. After incubation, the presence of bacteria was investigated by real-time polymerase chain reaction (PCR) and by the Enhanced Bacterial Detection System (eBDS, Pall) assay as a reference method. Real-time PCR amplification was performed with a set of universal primers and probes targeting the 16S rRNA gene. Co-amplification of human mitochondrial DNA served as an internal control. RESULTS Using the real-time PCR method, it was possible to detect the presence of all bacterial species tested with an initial concentration of 10 CFU mL-1 24 h after contamination, except for Staphylococcus hominis. The PCR assay also detected, at 24 h, the presence of Serratia marcescens and Enterobacter cloacae with an initial concentration of 1 CFU mL-1 . CONCLUSIONS The real-time PCR assay may be a reliable alternative to conventional culture methods in the screening of bacterial contamination of PCs, enabling bacterial detection even with a low initial concentration of microorganisms.
Collapse
Affiliation(s)
- J D Viana
- Fundação Pró-Sangue Hemocentro de São Paulo, São Paulo, Brazil
| | - S C Ferreira
- Fundação Pró-Sangue Hemocentro de São Paulo, São Paulo, Brazil
| | - S R Matana
- Fundação Pró-Sangue Hemocentro de São Paulo, São Paulo, Brazil
| | - F Rossi
- Departamento de Microbiologia do Laboratório Central, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
| | - P Patel
- Microbiology Services, NHS Blood and Transplant, London, UK
| | - J A Garson
- Microbiology Services, NHS Blood and Transplant, London, UK.,Division of Infection and Immunity, University College London, London, UK
| | - V Rocha
- Fundação Pró-Sangue Hemocentro de São Paulo, São Paulo, Brazil
| | - R Tedder
- Microbiology Services, NHS Blood and Transplant, London, UK.,Division of Infection and Immunity, University College London, London, UK
| | | | - J E Levi
- Fundação Pró-Sangue Hemocentro de São Paulo, São Paulo, Brazil
| |
Collapse
|
7
|
Störmer M, Wood EM, Gathof B. Microbial safety of cellular therapeutics-lessons from over ten years’ experience in microbial safety of platelet concentrates. ACTA ACUST UNITED AC 2018. [DOI: 10.1111/voxs.12452] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Melanie Störmer
- Transfusion Medicine; University Hospital Cologne; Cologne Germany
| | - Erica M. Wood
- Transfusion Research Unit; Department of Epidemiology and Preventive Medicine; Monash University; Melbourne VIC Australia
| | - Birgit Gathof
- Transfusion Medicine; University Hospital Cologne; Cologne Germany
| |
Collapse
|
8
|
Razjou F, Naghadeh HT, Ferdowsi S, Dabirmoghadam A. Evaluation of the Sensitivity and Specificity of Use of Glucose and pH for Bacterial Screening of Platelet Concentrates Compared to the Bact/Alert. Indian J Hematol Blood Transfus 2017; 33:116-120. [PMID: 28194067 DOI: 10.1007/s12288-016-0660-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2015] [Accepted: 02/10/2016] [Indexed: 11/27/2022] Open
Abstract
Bacterial contamination of blood components is the major infectious risk in transfusion medicine. Since platelets should be stored at room temperature that makes them an excellent growth medium for bacteria; it is mentioned as a major problem in transfusion medicine. Transfusion risk of a bacterial contaminated platelet concentrate is higher than viral pathogen such as HIV, HBV, HCV and HTLV. The objective of this study was to evaluation of the sensitivity and specificity of use of glucose and pH for bacterial screening of platelet concentrates compared to the Bact/Alert. 1332 platelet concentrates were screened by the Bact/Alert system for aerobic and anaerobic bacterial contamination. Bacterial contamination was also evaluated by using urine reagent strips (Multistix10 SG Bayer) and culture methods. Moreover PH screening with a pH meter (Metrohm 744 Swiss) and glucose was also used for detection of bacterial contamination. The rate of bacterial contamination detected by the Bact/Alert system in platelet concentrates was 25 in 1332 (1.9 %). It contained 15 (1.1 %) for aerobic bacteria and 10 (.8 %) for anaerobic bacteria. 226 of 1332 were considered as containing bacteria by using urine reagent strips. Six of the 226 units were also positive by the Bact/Alert system. Three of those units were culture positive for aerobic bacteria and three for anaerobic. The result of platelet concentrates that underwent pH screening by use of pH meter and a pH portion of urine reagent strips was the same. The sensitivity and specificity of considering glucose alone for detection of bacterial contamination were 12 and 98 % respectively. For pH alone, these were 24 and 83 %. For glucose and/or pH, these were 24 and 83 %; and for combination of glucose and pH, these were 12 and 98 %. Our results showed use of glucose/pH strips would improve the safety of blood products and should be encouraged.
Collapse
Affiliation(s)
- Farhad Razjou
- Blood Transfusion Research Center, High Institute for Research and Education in Transfusion Medicine, IBTO, Tehran, Iran
| | - Hossein Timori Naghadeh
- Blood Transfusion Research Center, High Institute for Research and Education in Transfusion Medicine, IBTO, Tehran, Iran
| | - Shirin Ferdowsi
- Blood Transfusion Research Center, High Institute for Research and Education in Transfusion Medicine, IBTO, Tehran, Iran
| | - Abolfazl Dabirmoghadam
- Blood Transfusion Research Center, High Institute for Research and Education in Transfusion Medicine, IBTO, Tehran, Iran
| |
Collapse
|
9
|
|
10
|
Silva MN, Vieira-Damiani G, Ericson ME, Gupta K, Gilioli R, de Almeida AR, Drummond MR, Lania BG, de Almeida Lins K, Soares TCB, Velho PENF. Bartonella henselae transmission by blood transfusion in mice. Transfusion 2016; 56:1556-9. [PMID: 26968530 DOI: 10.1111/trf.13545] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2015] [Revised: 12/09/2015] [Accepted: 01/09/2016] [Indexed: 12/26/2022]
Abstract
BACKGROUND Bartonella spp. are neglected fastidious Gram-negative bacilli. We isolated Bartonella henselae from 1.2% of 500 studied blood donors and demonstrated that the bacteria remain viable in red blood cell units after 35 days of experimental infection. Now, we aim to evaluate the possibility of B. henselae transmission by blood transfusion in a mouse model. STUDY DESIGN AND METHODS Eight BALB/c mice were intraperitoneal inoculated with a 30 µL of suspension with 10(4) CFU/mL of B. henselae and a second group of eight mice were inoculated with saline solution and used as control. After 96 hours of inoculation, the animals were euthanized. We collected blood and tissue samples from skin, liver, and spleen. Thirty microliters of blood from four Bartonella-inoculated animals were transfused into a new group (n = 4). Another group received blood from the control animals. B. henselae infection was investigated by conventional and nested polymerase chain reaction (PCR). RESULTS Blood samples from all 24 mice were negative by molecular tests though half of the tissue samples were positive by nested PCR in the intraperitoneal Bartonella-investigated animals. Tissues from two of the four mice that received blood transfusions from Bartonella-inoculated animals were also nested PCR positives. CONCLUSIONS Transmission of B. henselae by transfusion is possible in mice even when donor animals have undetectable bloodstream infection. The impact of human Bartonella sp. transmission through blood transfusion recipients must be evaluated.
Collapse
Affiliation(s)
- Marilene Neves Silva
- Division of Dermatology, Department of Medicine, University of Campinas (UNICAMP) Medical School, Campinas, SP, Brazil
| | - Gislaine Vieira-Damiani
- Division of Dermatology, Department of Medicine, University of Campinas (UNICAMP) Medical School, Campinas, SP, Brazil.,Federal Institute of Education, Science and Technology, Jaguariaiva, PR, Brazil
| | - Marna Elise Ericson
- Department of Dermatology, University of Minnesota Medical School, Minneapolis, Minnesota
| | - Kalpna Gupta
- Division of Hematology, Oncology and Transplantation, Department of Medicine, University of Minnesota Medical School, Minneapolis, Minnesota
| | - Rovilson Gilioli
- Laboratory of Animal Quality Control, Multidisciplinary Center of Biological Investigation (CEMIB), University of Campinas (UNICAMP), Campinas, SP, Brazil
| | - Amanda Roberta de Almeida
- Division of Dermatology, Department of Medicine, University of Campinas (UNICAMP) Medical School, Campinas, SP, Brazil
| | - Marina Rovani Drummond
- Division of Dermatology, Department of Medicine, University of Campinas (UNICAMP) Medical School, Campinas, SP, Brazil
| | - Bruno Grosselli Lania
- Division of Dermatology, Department of Medicine, University of Campinas (UNICAMP) Medical School, Campinas, SP, Brazil
| | - Karina de Almeida Lins
- Division of Dermatology, Department of Medicine, University of Campinas (UNICAMP) Medical School, Campinas, SP, Brazil
| | - Tânia Cristina Benetti Soares
- Division of Dermatology, Department of Medicine, University of Campinas (UNICAMP) Medical School, Campinas, SP, Brazil
| | | |
Collapse
|
11
|
Chew E, Benjamin RJ, McDonald CP, Wiersum-Osselton JC, Wood EM. International survey on definitions and current practices in prevention, diagnosis, management and reporting of transfusion-transmitted bacterial infections. ACTA ACUST UNITED AC 2015. [DOI: 10.1111/voxs.12176] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- E. Chew
- Department of Diagnostic Haematology; The Royal Melbourne Hospital; Grattan Street Parkville Vic. Australia
| | - R. J. Benjamin
- American Red Cross Biomedical Services; Rockville MD USA
| | | | | | - E. M. Wood
- Transfusion Research Unit; Monash Medical Centre; Monash University; Melbourne Vic. Australia
| | | |
Collapse
|
12
|
Damgaard C, Magnussen K, Enevold C, Nilsson M, Tolker-Nielsen T, Holmstrup P, Nielsen CH. Viable bacteria associated with red blood cells and plasma in freshly drawn blood donations. PLoS One 2015; 10:e0120826. [PMID: 25751254 PMCID: PMC4353618 DOI: 10.1371/journal.pone.0120826] [Citation(s) in RCA: 77] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2014] [Accepted: 01/26/2015] [Indexed: 01/28/2023] Open
Abstract
Objectives Infection remains a leading cause of post-transfusion mortality and morbidity. Bacterial contamination is, however, detected in less than 0.1% of blood units tested. The aim of the study was to identify viable bacteria in standard blood-pack units, with particular focus on bacteria from the oral cavity, and to determine the distribution of bacteria revealed in plasma and in the red blood cell (RBC)-fraction. Design Cross-sectional study. Blood were separated into plasma and RBC-suspensions, which were incubated anaerobically or aerobically for 7 days on trypticase soy blood agar (TSA) or blue lactose plates. For identification colony PCR was performed using primers targeting 16S rDNA. Setting Blood donors attending Capital Region Blood Bank, Copenhagen University Hospital, Rigshospitalet, Hvidovre, Denmark, October 29th to December 10th 2013. Participants 60 donors (≥50 years old), self-reported medically healthy. Results Bacterial growth was observed on plates inoculated with plasma or RBCs from 62% of the blood donations. Growth was evident in 21 (35%) of 60 RBC-fractions and in 32 (53%) of 60 plasma-fractions versus 8 of 60 negative controls (p = 0.005 and p = 2.6x10-6, respectively). Propionibacterium acnes was found in 23% of the donations, and Staphylococcus epidermidis in 38%. The majority of bacteria identified in the present study were either facultative anaerobic (59.5%) or anaerobic (27.8%) species, which are not likely to be detected during current routine screening. Conclusions Viable bacteria are present in blood from donors self-reported as medically healthy, indicating that conventional test systems employed by blood banks insufficiently detect bacteria in plasma. Further investigation is needed to determine whether routine testing for anaerobic bacteria and testing of RBC-fractions for adherent bacteria should be recommended.
Collapse
Affiliation(s)
- Christian Damgaard
- Section for Periodontology, Microbiology and Community Dentistry, Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
- Institute for Inflammation Research, Department of Infectious Diseases and Rheumatology, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
- * E-mail:
| | - Karin Magnussen
- Department of Clinical Immunology and Blood Centre, Rigshospitalet, Copenhagen University Hospital, Hvidovre, Denmark
| | - Christian Enevold
- Section for Periodontology, Microbiology and Community Dentistry, Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
- Institute for Inflammation Research, Department of Infectious Diseases and Rheumatology, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Martin Nilsson
- Costerton Biofilm Center, Department of International Health, Immunology and Microbiology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Tim Tolker-Nielsen
- Costerton Biofilm Center, Department of International Health, Immunology and Microbiology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Palle Holmstrup
- Section for Periodontology, Microbiology and Community Dentistry, Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Claus Henrik Nielsen
- Section for Periodontology, Microbiology and Community Dentistry, Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
- Institute for Inflammation Research, Department of Infectious Diseases and Rheumatology, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| |
Collapse
|
13
|
Webster J, Bell-Syer SEM, Foxlee R. Skin preparation with alcohol versus alcohol followed by any antiseptic for preventing bacteraemia or contamination of blood for transfusion. Cochrane Database Syst Rev 2015; 2015:CD007948. [PMID: 25674776 PMCID: PMC7185566 DOI: 10.1002/14651858.cd007948.pub3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Blood for transfusion may become contaminated at any point between collection and transfusion and may result in bacteraemia (the presence of bacteria in the blood), severe illness or even death for the blood recipient. Donor arm skin is one potential source of blood contamination, so it is usual to cleanse the skin with an antiseptic before blood donation. One-step and two-step alcohol based antiseptic regimens are both commonly advocated but there is uncertainty as to which is most effective. OBJECTIVES To assess the effects of cleansing the skin of blood donors with alcohol in a one-step compared with alcohol in a two-step procedure to prevent contamination of collected blood or bacteraemia in the recipient. SEARCH METHODS In December 2014, for this third update, we searched the Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL), The Cochrane Library; Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. SELECTION CRITERIA All randomised trials (RCTs) comparing alcohol based donor skin cleansing in a one-step versus a two-step process that includes alcohol and any other antiseptic for pre-venepuncture skin cleansing were considered. Quasi randomised trials were to have been considered in the absence of RCTs. DATA COLLECTION AND ANALYSIS Two review authors independently assessed studies for inclusion. MAIN RESULTS No studies (RCTs or quasi RCTs) met the inclusion criteria. AUTHORS' CONCLUSIONS We did not identify any eligible studies for inclusion in this review. It is therefore unclear whether a two-step, alcohol followed by antiseptic skin cleansing process prior to blood donation confers any reduction in the risk of blood contamination or bacteraemia in blood recipients, or conversely whether a one-step process increases risk above that associated with a two-step process.
Collapse
Affiliation(s)
- Joan Webster
- Centre for Clinical Nursing, Royal Brisbane and Women's Hospital, Level 2, Building 34, Butterfield Street, Brisbane, Queensland, Australia, 4029. .
| | | | | |
Collapse
|
14
|
Pruett CR, Vermeulen M, Zacharias P, Ingram C, Tayou Tagny C, Bloch EM. The use of rapid diagnostic tests for transfusion infectious screening in Africa: a literature review. Transfus Med Rev 2014; 29:35-44. [PMID: 25447555 DOI: 10.1016/j.tmrv.2014.09.003] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2014] [Revised: 09/09/2014] [Accepted: 09/16/2014] [Indexed: 12/22/2022]
Abstract
Infectious risk associated with blood transfusion remains a major public health challenge in Africa, where prevalence rates of the major transfusion-transmissible infections (ie, hepatitis B, hepatitis C, human immunodeficiency virus, and syphilis) are among the highest in the world. Resource-limited blood services often operate with minimal predonation screening safeguards, prompting exclusive reliance on laboratory testing to mitigate infectious risk. Transfusion screening with rapid diagnostic tests (RDTs) has been adopted in areas that lack the capacity to support the routine use of more sophisticated technologies. However, uncertainty surrounding the performance of some RDTs in the field has spurred debate regarding their application to blood donation screening. Our review of the literature identified 17 studies that evaluated RDTs for the infectious screening of blood donors in Africa. The review highlights the variable performance of available RDTs and the importance of their use in a quality-assured manner. Deficiencies in performance observed with some RDTs underscore the need to validate test kits prior to use under field conditions with locally acquired samples. Suboptimal sensitivities of some available tests, specifically hepatitis B virus rapid assays, question their suitability in single-test algorithms, particularly in high-prevalence regions. Although RDTs have limitations, many of which can be addressed through improved training and quality systems, they are frequently the only viable option for infectious screening in resource-poor African countries. Therefore, additional studies and specific guidelines regarding the use of RDTs in the context of blood safety are needed.
Collapse
Affiliation(s)
| | - Marion Vermeulen
- South African National Blood Service, Johannesburg, South Africa
| | | | - Charlotte Ingram
- South African National Blood Service, Johannesburg, South Africa
| | | | - Evan M Bloch
- Blood Systems Research Institute, San Francisco, CA; University of California San Francisco, San Francisco, CA
| |
Collapse
|
15
|
Webster J, Bell-Syer SEM, Foxlee R. Skin preparation with alcohol versus alcohol followed by any antiseptic for preventing bacteraemia or contamination of blood for transfusion. Cochrane Database Syst Rev 2013:CD007948. [PMID: 23440821 DOI: 10.1002/14651858.cd007948.pub2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND Blood for transfusion may become contaminated at any point between collection and transfusion and may result in bacteraemia (the presence of bacteria in the blood), severe illness or even death for the blood recipient. Donor arm skin is one potential source of blood contamination, so it is usual to cleanse the skin with an antiseptic before blood donation. One-step and two-step alcohol based antiseptic regimens are both commonly advocated but there is uncertainty as to which is most effective. OBJECTIVES To assess the effects of cleansing the skin of blood donors with alcohol in a one-step compared with alcohol in a two-step procedure to prevent contamination of collected blood or bacteraemia in the recipient. SEARCH METHODS For this second update we searched the Cochrane Wounds Group Specialised Register (searched 20 November 2012); The Cochrane Central Register of Controlled Trials (CENTRAL) The Cochrane Library 2012, Issue 11; Ovid MEDLINE (20011 to November Week 2 2012); Ovid MEDLINE (In-Process & Other Non-Indexed Citations November 20, 2012); Ovid EMBASE ( 20011 to 2012 Week 46); and EBSCO CINAHL ( 2008 to 15 November 2012). SELECTION CRITERIA All randomised trials (RCTs) comparing alcohol based donor skin cleansing in a one-step versus a two-step process that includes alcohol and any other antiseptic for pre-venepuncture skin cleansing were considered. Quasi randomised trials were to have been considered in the absence of RCTs. DATA COLLECTION AND ANALYSIS Two review authors independently assessed studies for inclusion. MAIN RESULTS No studies (RCTs or quasi RCTs) met the inclusion criteria. AUTHORS' CONCLUSIONS We did not identify any eligible studies for inclusion in this review. It is therefore unclear whether a two-step, alcohol followed by antiseptic skin cleansing process prior to blood donation confers any reduction in the risk of blood contamination or bacteraemia in blood recipients, or conversely whether a one-step process increases risk above that associated with a two-step process.
Collapse
Affiliation(s)
- Joan Webster
- Centre for Clinical Nursing, Royal Brisbane andWomen’s Hospital, Brisbane,
| | | | | |
Collapse
|
16
|
Lee C, Chan H, Ho P, Wong H, Leung J, Tsoi W, Lin C. Long-term clinical outcomes afterStreptococcus bovisisolation in asymptomatic blood donors in Hong Kong. Transfusion 2013; 53:2207-10. [DOI: 10.1111/trf.12087] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2012] [Revised: 11/17/2012] [Accepted: 11/18/2012] [Indexed: 12/24/2022]
|
17
|
Lee CK, Wong HK, Ho PL, Tsoi WC, Lee KY, Tsui GTF, Chua E, Leung JNS, Lin CK. Significant bacterial contamination risk reduction with the use of diversion pouch. Transfus Med 2012; 22:404-8. [DOI: 10.1111/j.1365-3148.2012.01194.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2012] [Revised: 09/05/2012] [Accepted: 09/09/2012] [Indexed: 11/30/2022]
Affiliation(s)
- C. K. Lee
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| | - H. K. Wong
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| | - P. L. Ho
- Department of Microbiology; The University of Hong Kong; Hong Kong; SAR; China
| | - W. C. Tsoi
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| | - K. Y. Lee
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| | - G. T. F. Tsui
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| | - E. Chua
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| | - J. N. S. Leung
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| | - C. K. Lin
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| |
Collapse
|
18
|
Proteomic analysis of Intercept-treated platelets. J Proteomics 2012; 76 Spec No.:316-28. [PMID: 22813878 DOI: 10.1016/j.jprot.2012.07.008] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2012] [Revised: 07/02/2012] [Accepted: 07/05/2012] [Indexed: 12/20/2022]
Abstract
In the past decades, transfusion medicine has been driven by the quest for increased safety against transfusion-transmitted infections, mainly by better donor selection and by the development of improved serological and nucleic-acid-based screening assays. Recently, pathogen reduction technologies became available and started to be implemented in several countries, with the primary goal to fight against bacterial contamination of blood products, a rare but dramatic event against which there was no definitive measure. Though pathogen reduction technologies represent a quantum leap in transfusion safety, the biomedical efficacy of platelet concentrates (PCs) treated with various pathogen reduction techniques has been recently questioned by clinical studies. Here, a gel-based proteomic analysis of PCs (n=5), Intercept-treated or untreated, from pooled buffy-coat (10 donors per PC) at Days 1, 2 and 8, shows that the Intercept process that is the most widespread pathogen reduction technique to date, has relatively low impact on the proteome of treated platelets: the process induces modifications of DJ-1 protein, glutaredoxin 5, and G(i)alpha 2 protein. As for the impact of storage, chloride intracellular channel protein 4 (CLIC4) and actin increased independently of Intercept treatment during storage. Whereas alteration of the DJ-1 protein and glutaredoxin 5 points out an oxidative stress-associated lesion, modification of G(i)alpha2 directly connects a possible Intercept-associated lesion to haemostatic properties of Intercept-treated platelets. This article is part of a Special Issue entitled: Integrated omics.
Collapse
|
19
|
Celere MS, Ferreira O, Ubiali EMA, Julião FC, Fernandes AFT, de Andrade D, Segura-Muñoz SI. Antimicrobial activity of two techniques for arm skin disinfection of blood donors in Brazil. Transfus Med 2012; 22:116-21. [DOI: 10.1111/j.1365-3148.2012.01132.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- M S Celere
- Regional Blood Center of Ribeirão Preto, Ribeirão Preto, São Paulo, Brazil
| | | | | | | | | | | | | |
Collapse
|
20
|
Tokuno O, Hayakawa I, Hashimoto M, Nakamura M, Sugimoto T, Minami H. Evaluation with the BacT/ALERT microbial detection system of bacterial contamination in autologous blood donation and transfusion. Transfus Med 2011; 22:73-4. [PMID: 22118577 DOI: 10.1111/j.1365-3148.2011.01116.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
21
|
Borosak M, Wood E. Bacterial Pre-Release Testing of Platelets - the Australian Red Cross Blood Service Clinical Experience. ACTA ACUST UNITED AC 2011; 38:239-241. [PMID: 22016693 DOI: 10.1159/000330466] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2011] [Accepted: 07/01/2011] [Indexed: 11/19/2022]
Abstract
SUMMARY: The risk of bacterial transmission by platelet transfusion has been recognised internationally as the leading residual infections transfusion risk in the last decade. We describe the clinical and logistical aspects of bacterial contamination screening of platelets introduced in Australia in early 2008. Sampling occurs at 24 h, and platelets are released to hospitals 'negative to date'. Bacterial screening detection of initial machine-positive (IMP) and all follow-up results are notified to transfusing laboratories. Results of screening between 2008 and 2010 found a significant rate of IMP samples (1.06%) with a true-positive/indeterminate rate of 0.18%. Components were already transfused in 32.5% of cases at time of initial notification. Confirmed cases of septic transfusion reactions have declined significantly since the introduction of pre-release platelet screening, reflecting an important additional improvement in transfusion safety in Australia.
Collapse
Affiliation(s)
- Marija Borosak
- Transfusion Medicine Services, Australian Red Cross Blood Service, South Melbourne, Australia
| | | |
Collapse
|
22
|
Walther-Wenke G, Däubener W, Heiden M, Hoch J, Hornei B, Volkers P, von König CHW. Effect of Safety Measures on Bacterial Contamination Rates of Blood Components in Germany. ACTA ACUST UNITED AC 2011; 38:231-235. [PMID: 22016691 DOI: 10.1159/000330417] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2011] [Accepted: 06/29/2011] [Indexed: 11/19/2022]
Abstract
SUMMARY: Requirements for bacterial testing of blood components on a defined quantity as part of routine quality control were introduced in Germany by the National Advisory Committee Blood of the German Federal Ministry of Health in 1997. The philosophy was to establish standardized methods for bacterial testing. Numerous measures to reduce the risk of bacterial contamination were implemented into the blood donation and manufacturing processes between 1999 and 2002. German Blood establishments performed culture-based bacterial testing on random samples of platelet concentrates (PCs), red blood cells (RBCs) and fresh frozen plasma (FFP) and reported data out of the production periods 1998, 2001 and 2005/2006. While the bacterial contamination rate of apheresis PCs remained nearly unchanged, it decreased by 70% for pooled PCs to a rate of 0.158% in the last observation period. Leukocyte-depleted RBCs with diversion of the initial blood volume showed a contamination rate of 0.029% which is significantly lower than that of RBCs without leukocyte depletion and diversion (0.157%). The contamination rate of plasma decreased by 80%. Preventive measures resulted in a significant reduction of bacterial contamination of blood components. Long-term monitoring with standardized methods for bacteria testing supports evaluation of the cumulative effect of contamination reducing measures.
Collapse
|
23
|
Müller TH, Montag T, Seltsam AW. Laboratory Evaluation of the Effectiveness of Pathogen Reduction Procedures for Bacteria. ACTA ACUST UNITED AC 2011; 38:242-250. [PMID: 22016694 DOI: 10.1159/000330338] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2011] [Accepted: 05/05/2011] [Indexed: 11/19/2022]
Abstract
SUMMARY: Bacterial contamination remains a leading factor for transfusion-associated serious morbidity and mortality. Pathogen reduction procedures offer a pro-active approach to prevent bacterial contamination of cellular blood components and especially of platelet concentrates. In the past, the laboratory evaluation of the effectiveness of the pathogen reduction procedures to minimise the bacterial load of blood components has been primarily based on log reduction assays similar to the assessment of antiviral activities. Bacteria strains with the ability to multiply in the blood components are seeded in highest possible cell numbers, the pathogen reduction procedure is applied, and the post-treatment number of bacteria is measured. The effectiveness of the procedure is characterised by calculating the log reduction of the post- to pre-treatment bacteria titres. More recently, protocols have been developed for experiments starting with a low bacteria load and monitoring the sterility of the blood component during the entire storage period of the blood component. Results for 3 different pathogen reduction technologies in these experimental models are compared and critical determinants for the results are addressed. The heterogeneity of results observed for different strains suggests that the introduction of international transfusion-relevant bacterial reference strains may facilitate the validity of findings in pathogen reduction experiments.
Collapse
Affiliation(s)
- Thomas H Müller
- DRK-Blutspendedienst NSTOB, Institut Springe, Langen, Germany
| | | | | |
Collapse
|
24
|
Störmer M, Arroyo A, Brachert J, Carrero H, Devine D, Epstein JS, Gabriel C, Gelber C, Goodrich R, Hanschmann KM, Heath DG, Jacobs MR, Keil S, de Korte D, Lambrecht B, Lee CK, Marcelis J, Marschner S, McDonald C, McGuane S, McKee M, Müller TH, Muthivhi T, Pettersson A, Radziwon P, Ramirez-Arcos S, Reesink HW, Rojo J, Rood I, Schmidt M, Schneider CK, Seifried E, Sicker U, Wendel S, Wood EM, Yomtovian RA, Montag T. Establishment of the first international repository for transfusion-relevant bacteria reference strains: ISBT working party transfusion-transmitted infectious diseases (WP-TTID), subgroup on bacteria. Vox Sang 2011; 102:22-31. [PMID: 21732948 DOI: 10.1111/j.1423-0410.2011.01510.x] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Bacterial contamination of platelet concentrates (PCs) still remains a significant problem in transfusion with potential important clinical consequences, including death. The International Society of Blood Transfusion Working Party on Transfusion-Transmitted Infectious Diseases, Subgroup on Bacteria, organised an international study on Transfusion-Relevant Bacteria References to be used as a tool for development, validation and comparison of both bacterial screening and pathogen reduction methods. MATERIAL AND METHODS Four Bacteria References (Staphylococcus epidermidis PEI-B-06, Streptococcus pyogenes PEI-B-20, Klebsiella pneumoniae PEI-B-08 and Escherichia coli PEI-B-19) were selected regarding their ability to proliferate to high counts in PCs and distributed anonymised to 14 laboratories in 10 countries for identification, enumeration and bacterial proliferation in PCs after low spiking (0·3 and 0·03 CFU/ml), to simulate contamination occurring during blood donation. RESULTS Bacteria References were correctly identified in 98% of all 52 identifications. S. pyogenes and E. coli grew in PCs in 11 out of 12 laboratories, and K. pneumoniae and S. epidermidis replicated in all participating laboratories. The results of bacterial counts were very consistent between laboratories: the 95% confidence intervals were for S. epidermidis: 1·19-1·32 × 10(7) CFU/ml, S. pyogenes: 0·58-0·69 × 10(7) CFU/ml, K. pneumoniae: 18·71-20·26 × 10(7) CFU/ml and E. coli: 1·78-2·10 × 10(7) CFU/ml. CONCLUSION The study was undertaken as a proof of principle with the aim to demonstrate (i) the quality, stability and suitability of the bacterial strains for low-titre spiking of blood components, (ii) the property of donor-independent proliferation in PCs, and (iii) their suitability for worldwide shipping of deep frozen, blinded pathogenic bacteria. These aims were successfully fulfilled. The WHO Expert Committee Biological Standardisation has approved the adoption of these four bacteria strains as the first Repository for Transfusion-Relevant Bacteria Reference Strains and, additionally, endorsed as a project the addition of six further bacteria strain preparations suitable for control of platelet contamination as the next step of enlargement of the repository.
Collapse
Affiliation(s)
- M Störmer
- Paul Ehrlich Institute, Langen, Germany.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Vollmer T, Engemann J, Kleesiek K, Dreier J. Bacterial screening by flow cytometry offers potential for extension of platelet storage: results of 14 months of active surveillance. Transfus Med 2011; 21:175-82. [DOI: 10.1111/j.1365-3148.2011.01070.x] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
26
|
Walther-Wenke G, Wirsing von König CH, Däubener W, Heiden M, Hoch J, Hornei B, Volkers P. Monitoring bacterial contamination of blood components in Germany: effect of contamination reduction measures. Vox Sang 2010; 100:359-66. [DOI: 10.1111/j.1423-0410.2010.01432.x] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
27
|
Cawley C, McDonald C, Ancliff S, Roy A, MacLennan S, Brant L, Pichon B, Brailsford S. Early recognition and reporting of suspected bacterial contamination may prevent transfusion transmission of infection by associated units. Transfus Med 2010; 21:70-2. [DOI: 10.1111/j.1365-3148.2010.01043.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
28
|
Martínez F, Tarrand J, Lichtiger B. Impact on patient outcome following transfusion of bacterially contaminated platelets: the M.D. Anderson Cancer Center experience. Am J Clin Pathol 2010; 134:207-12. [PMID: 20660322 DOI: 10.1309/ajcps9yv7ytomrrh] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
This study examined the clinical outcome of every patient who received a bacterially contaminated unit of platelets at The University of Texas M.D. Anderson Cancer Center, Houston, during 2007. Samples of platelets were aerobically cultured and read for 1 day at 35 degrees C. Positive bottles were subcultured in the appropriate media. The effect of independent variables in the clinical outcome of patients infused with bacterially contaminated platelet units was analyzed. A total of 23,199 platelet units were transfused, 71 of which were bacterially contaminated units; 8 were apheresis platelets and 63 were whole blood platelets. Of the 71 units, 70 were contaminated with gram-positive bacteria and 1 with gram-negative bacteria. Only 1 patient developed fever, and coagulase-negative staphylococci were isolated from the transfused unit. Transfusion of fresh units and antibiotic therapy possibly explain the lack of clinical consequences in our patients.
Collapse
|
29
|
|
30
|
|
31
|
|
32
|
Hassall O, Maitland K, Pole L, Mwarumba S, Denje D, Wambua K, Lowe B, Parry C, Mandaliya K, Bates I. Bacterial contamination of pediatric whole blood transfusions in a Kenyan hospital. Transfusion 2009; 49:2594-8. [PMID: 19682331 PMCID: PMC2939982 DOI: 10.1111/j.1537-2995.2009.02344.x] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND: Hospitalized children in sub-Saharan Africa frequently receive whole blood transfusions for severe anemia. The risk from bacterial contamination of blood for transfusion in sub-Saharan Africa is not known. This study assessed the frequency of bacterial contamination of pediatric whole blood transfusions at a referral hospital in Kenya. STUDY DESIGN AND METHODS: This was an observational study. Over the course of 1 year, bacteriologic cultures were performed on 434 of the 799 blood packs issued to children by the blood bank of Coast Provincial General Hospital, Mombasa. Clinical outcome was not assessed. RESULTS: Forty-four bacterial contaminants were isolated from 38 blood packs—an overall contamination frequency of 8.8% (95% confidence interval, 6.1%-11.4%). Sixty-four percent of the bacteria isolated were Gram-negative. Many of the isolates are usually found in the environment and the most likely source of contamination was considered to be the hospital blood bank. CONCLUSION: Bacterial contamination of whole blood may be a significant but unrecognized hazard of blood transfusion for children in sub-Saharan Africa. Further work is needed to clarify the extent of the problem and its clinical consequences. Increased awareness and adherence to basic principles of asepsis in the hospital blood bank may be important immediate interventions.
Collapse
Affiliation(s)
- Oliver Hassall
- Centre for Geographic Medicine Research (Coast), Kenya Medical Research Institute/Wellcome Trust Research Programme, Kilifi, Kenya
| | | | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Webster J, Bell-Syer SE, Foxlee R. Skin preparation with alcohol versus alcohol followed by any antiseptic for preventing bacteraemia or contamination of blood for transfusion. Cochrane Database Syst Rev 2009:CD007948. [PMID: 19588446 DOI: 10.1002/14651858.cd007948] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND Blood for transfusion may become contaminated at any point between collection and transfusion and may result in bacteraemia (the presence of bacteria in the blood), severe illness or even death for the blood recipient. Donor arm skin is one potential source of blood contamination, so it is usual to cleanse the skin with an antiseptic before blood donation. One-step and two-step alcohol based antiseptic regimens are both commonly advocated but there is uncertainty as to which is most effective. OBJECTIVES To assess the effects of cleansing the skin of blood donors with alcohol in a one-step compared with alcohol in a two-step procedure to prevent contamination of collected blood or bacteraemia in the recipient. SEARCH STRATEGY We searched the Cochrane Wounds Group Specialised Register (March 10 2009); The Cochrane Central Register of Controlled Trials (CENTRAL) The Cochrane Library 2009, Issue 1; Ovid MEDLINE - (1950 to February Week 4 2009); Ovid EMBASE - (1980 to 2009 Week 9); and EBSCO CINAHL - (1982 to February Week 4 2009). We also searched the reference lists of key papers. SELECTION CRITERIA All randomised trials (RCTs) comparing alcohol based donor skin cleansing in a one-step versus a two-step process that includes alcohol and any other antiseptic for pre-venepuncture skin cleansing were considered. Quasi randomised trials were to have been considered in the absence of RCTs. DATA COLLECTION AND ANALYSIS Two review authors independently assessed studies for inclusion. MAIN RESULTS No studies (RCTs or quasi RCTs) met the inclusion criteria. AUTHORS' CONCLUSIONS We did not identify any eligible studies for inclusion in this review. It is therefore unclear whether a two-step, alcohol followed by antiseptic skin cleansing process prior to blood donation confers any reduction in the risk of blood contamination or bacteraemia in blood recipients, or conversely whether a one-step process increases risk above that associated with a two-step process.
Collapse
Affiliation(s)
- Joan Webster
- Centre for Clinical Nursing, Royal Brisbane and Women's Hospital, Level 2, Building 34, Butterfield Street, Herston, QLD, Australia, 4029
| | | | | |
Collapse
|
34
|
Dreier J, Vollmer T, Kleesiek K. Novel flow cytometry-based screening for bacterial contamination of donor platelet preparations compared with other rapid screening methods. Clin Chem 2009; 55:1492-502. [PMID: 19498052 DOI: 10.1373/clinchem.2008.122515] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Bacterial contamination is the major infectious hazard associated with transfusion of platelet preparations (PLTs). Routine testing for bacterial contamination in PLTs has become common, but transfusion-transmitted bacterial sepsis has not been eliminated. Here, we describe a novel flow cytometry-based method for point-of-issue screening of PLTs for bacterial contamination. METHODS We used the BactiFlow flow cytometer to detect and count bacteria based on esterase activity in viable cells. We compared the assay to incubation (BacT/Alert culture system) and rapid nucleic acid-based or immunoassay (reverse transcription PCR, Pan Genera Detection) methods. RESULTS We established a protocol for bacterial screening of PLTs consisting of enzymatic digestion and centrifugal filtration for the elimination of viable platelets and selective labeling of bacteria with fluorescent esterase substrate (ChemChrome V23). Results from the BactiFlow showed an excellent correlation (r = 0.9923 E. coli, r = 0.9736 S. epidermidis) to traditional plate count results. The lower detection limit of the assay was determined to be 150 CFU/mL, and the time to result was <1 h. CONCLUSIONS Our study demonstrates that BactiFlow flow cytometry is suitable for rapid screening of PLTs for bacterial contamination and fulfils the requirements for a point-of-issue testing of PLTs with acceptable time to result, specificity, sensitivity, and cost.
Collapse
Affiliation(s)
- Jens Dreier
- Institut für Laboratoriums- und Transfusionsmedizin, Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
| | | | | |
Collapse
|
35
|
Mohr H, Gravemann U, Bayer A, Müller TH. Sterilization of platelet concentrates at production scale by irradiation with short-wave ultraviolet light. Transfusion 2009; 49:1956-63. [DOI: 10.1111/j.1537-2995.2009.02228.x] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
36
|
Liumbruno GM, Catalano L, Piccinini V, Pupella S, Grazzini G. Reduction of the risk of bacterial contamination of blood components through diversion of the first part of the donation of blood and blood components. BLOOD TRANSFUSION = TRASFUSIONE DEL SANGUE 2009; 7:86-93. [PMID: 19503628 PMCID: PMC2689061 DOI: 10.2450/2008.0026-08] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 07/05/2008] [Accepted: 11/11/2008] [Indexed: 11/21/2022]
|
37
|
McKane AV, Ward N, Senn C, Eubanks J, Wessels L, Bowman R. Analysis of bacterial detection in whole blood-derived platelets by quantitative glucose testing at a university medical center. Am J Clin Pathol 2009; 131:542-51. [PMID: 19289590 DOI: 10.1309/ajcpvn9ot4grcsko] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Abstract
After the March 2004 implementation of American Association of Blood Banks standards regarding platelet bacterial detection, we began quantitative glucose screening of whole blood-derived platelets (WB-P). The glucose level was measured immediately before component release--often storage day 4 or 5--using the Glucometer SureStep Flexx Meter (LifeScan, Milpitas, CA), with a positive cutoff of less than 500 mg/dL; failing units were cultured and not transfused. During 29 months (March 1, 2004-July 31, 2006) 93,073 units of WB-P were tested. Initially, 929 units (0.998%) screened positively. Bacterial growth was culture-confirmed in 6 units, for a bacterial contamination incidence of 0.006% and a true-positive rate of 6.4/100,000. Three additional culture-confirmed contamination cases were detected in transfused units causing febrile nonhemolytic reactions, for a false-negative rate of 3.2/100,000. Our overall contamination prevalence was 9.6/100,000 units of platelets transfused, lower than ordinarily cited, and showed a false-negative rate remarkably congruent to that of culture: 3.2/100,000. A low-sensitivity screening test applied late in platelet shelf-life can be comparable to culture in preventing bacterial-related morbidity.
Collapse
|
38
|
|
39
|
Dreier J, Störmer M, Pichl L, Schottstedt V, Grolle A, Bux J, Kleesiek K. Sterility screening of platelet concentrates: questioning the optimal test strategy. Vox Sang 2008; 95:181-8. [DOI: 10.1111/j.1423-0410.2008.01087.x] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
40
|
Garraud O, Pelletier B, Aznar C. Pourquoi ajourner au don de sang des candidats au motif d’un risque de maladie de Chagas ? Transfus Clin Biol 2008; 15:123-8. [DOI: 10.1016/j.tracli.2008.05.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2007] [Accepted: 05/05/2008] [Indexed: 10/21/2022]
|
41
|
Störmer M, Kleesiek K, Dreier J. Propionibacterium acnes lacks the capability to proliferate in platelet concentrates. Vox Sang 2008; 94:193-201. [PMID: 18086288 DOI: 10.1111/j.1423-0410.2007.01019.x] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND AND OBJECTIVES Propionibacterium acnes is considered to be one of the most frequent contaminants of platelet concentrates (PCs) when anaerobic culture-based detection methods are used. But Propionibacteria are often detected too late when blood products have already been transfused. Therefore, its transfusion relevance is still demanding clarification because studies of the outcome of patients transfused with P. acnes-contaminated PCs are still uncommon. In this study, we monitored clinical effects in patients after transfusion of PCs, which were detected too late in sterility testing. Furthermore, we assessed the bacterial proliferation of Propionibacterium species seeded into PCs to clarify their significance for platelet bacteria screening. MATERIALS AND METHODS In the look-back process, we followed the route of the putative contaminated PC units from storage to transfusion. In the in vitro study, PCs were inoculated with 1-100 colony-forming unit (CFU)/ml of clinical isolates of Propionibacteria (n = 10). Sampling was performed during 10-day aerobic storage at 22 degrees C. The presence of bacteria was assessed by plating culture and automated BacT/Alert culture system. RESULTS Propionibacterium acnes shows slow or no growth under PC storage conditions. Clinical signs of adverse events after transfusion of potentially contaminated PC units were not reported. CONCLUSION Propionibacteria do not proliferate under PC storage conditions and therefore may be missed or detected too late when blood products have already been transfused.
Collapse
Affiliation(s)
- M Störmer
- Institut für Laboratoriums- und Transfusionsmedizin, Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - K Kleesiek
- Institut für Laboratoriums- und Transfusionsmedizin, Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - J Dreier
- Institut für Laboratoriums- und Transfusionsmedizin, Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| |
Collapse
|
42
|
Störmer M, Kleesiek K, Dreier J. pH value promotes growth of Staphylococcus epidermidis in platelet concentrates. Transfusion 2008; 48:836-46. [PMID: 18298602 DOI: 10.1111/j.1537-2995.2008.01644.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND The platelet (PLT) storage lesion is characterized metabolically by a pH value associated with lactic acid generation. PLT storage conditions support the growth of Staphylococcus epidermidis, the most common organism implicated in bacterial contamination of PLT concentrates (PCs). Here, different factors that influence bacterial growth in PCs are discussed and the relation between pH values of PCs and citrate plasma (CP) is studied, with emphasis on bacterial proliferation. STUDY DESIGN AND METHODS The PLT lesion with regard to pH decrease and lactic acid production was monitored during storage and correlated to bacterial proliferation properties. A total of 115 coagulase-negative staphylococci, especially S. epidermidis isolates, were characterized for their proliferation in different blood components (CP, buffy coat-derived, and apheresis PCs). Furthermore, the influence of donor-specific, product-specific, species-specific, and strain-specific factors on bacterial proliferation was investigated. RESULTS PCs showed a lower pH value in comparison to plasma during storage. Bacterial proliferation in PCs and the failure to grow in CP were determined with all organisms tested. No correlation to donor-specific, species-specific, or strain-specific factors was observed. Lowering the pH of CP resulted in bacterial proliferation, whereas a pH increase in the PC unit inhibited the proliferation of S. epidermidis. CONCLUSION With emphasis on bacterial proliferation, the significant difference between PC and CP is the presence of metabolizing PLTs. The pH values of stored PLTs, but not those of stored plasma, support the growth of S. epidermidis.
Collapse
Affiliation(s)
- Melanie Störmer
- Institut für Laboratoriums- und Transfusionsmedizin, Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | | | | |
Collapse
|
43
|
|