Enevoldsen J, Simpson GL, Vistisen ST. Using generalized additive models to decompose time series and waveforms, and dissect heart-lung interaction physiology. J Clin Monit Comput 2023; 37:165-177. [PMID: 35695942 PMCID: PMC9852126 DOI: 10.1007/s10877-022-00873-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Accepted: 05/02/2022] [Indexed: 01/24/2023]
Abstract
Common physiological time series and waveforms are composed of repeating cardiac and respiratory cycles. Often, the cardiac effect is the primary interest, but for, e.g., fluid responsiveness prediction, the respiratory effect on arterial blood pressure also convey important information. In either case, it is relevant to disentangle the two effects. Generalized additive models (GAMs) allow estimating the effect of predictors as nonlinear, smooth functions. These smooth functions can represent the cardiac and respiratory cycles' effects on a physiological signal. We demonstrate how GAMs allow a decomposition of physiological signals from mechanically ventilated subjects into separate effects of the cardiac and respiratory cycles. Two examples are presented. The first is a model of the respiratory variation in pulse pressure. The second demonstrates how a central venous pressure waveform can be decomposed into a cardiac effect, a respiratory effect and the interaction between the two cycles. Generalized additive models provide an intuitive and flexible approach to modelling the repeating, smooth, patterns common in medical monitoring data.
Collapse
Affiliation(s)
- Johannes Enevoldsen
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200, Aarhus N, Denmark. .,Department of Anaesthesiology and Intensive Care, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark.
| | - Gavin L Simpson
- Department of Animal Science, Aarhus University, Tjele, Denmark
| | - Simon T Vistisen
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200, Aarhus N, Denmark.,Department of Anaesthesiology and Intensive Care, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
| |
Collapse
|
2
|
Flick M, Sand U, Bergholz A, Kouz K, Reiter B, Flotzinger D, Saugel B, Kubitz JC. Right ventricular and pulmonary artery pulse pressure variation and systolic pressure variation for the prediction of fluid responsiveness: an interventional study in coronary artery bypass surgery patients. J Clin Monit Comput 2022; 36:1817-1825. [PMID: 35233702 DOI: 10.1007/s10877-022-00830-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Accepted: 02/07/2022] [Indexed: 11/29/2022]
Abstract
PURPOSE Predicting fluid responsiveness is essential when treating surgical or critically ill patients. When using a pulmonary artery catheter, pulse pressure variation and systolic pressure variation can be calculated from right ventricular and pulmonary artery pressure waveforms. METHODS We conducted a prospective interventional study investigating the ability of right ventricular pulse pressure variation (PPVRV) and systolic pressure variation (SPVRV) as well as pulmonary artery pulse pressure variation (PPVPA) and systolic pressure variation (SPVPA) to predict fluid responsiveness in coronary artery bypass (CABG) surgery patients. Additionally, radial artery pulse pressure variation (PPVART) and systolic pressure variation (SPVART) were calculated. The area under the receiver operating characteristics (AUROC) curve with 95%-confidence interval (95%-CI) was used to assess the capability to predict fluid responsiveness (defined as an increase in cardiac index of > 15%) after a 500 mL crystalloid fluid challenge. RESULTS Thirty-three patients were included in the final analysis. Thirteen patients (39%) were fluid-responders with a mean increase in cardiac index of 25.3%. The AUROC was 0.60 (95%-CI 0.38 to 0.81) for PPVRV, 0.63 (95%-CI 0.43 to 0.83) for SPVRV, 0.58 (95%-CI 0.38 to 0.78) for PPVPA, and 0.71 (95%-CI 0.52 to 0.89) for SPVPA. The AUROC for PPVART was 0.71 (95%-CI 0.53 to 0.89) and for SPVART 0.78 (95%-CI 0.62 to 0.94). The correlation between pulse pressure variation and systolic pressure variation measurements derived from the different waveforms was weak. CONCLUSIONS Right ventricular and pulmonary artery pulse pressure variation and systolic pressure variation seem to be weak predictors of fluid responsiveness in CABG surgery patients.
Collapse
Affiliation(s)
- Moritz Flick
- Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Ulrike Sand
- Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Alina Bergholz
- Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Karim Kouz
- Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Beate Reiter
- Department of Cardiovascular Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | | | - Bernd Saugel
- Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Outcomes Research Consortium, Cleveland, Ohio, USA
| | - Jens Christian Kubitz
- Department of Anesthesiology and Intensive Care Medicine, Paracelsus Medical University Nuremberg, Prof.-Ernst-Nathan-Str. 1, 90419, Nuremberg, Germany.
| |
Collapse
|
3
|
Messina A, Calabrò L, Pugliese L, Lulja A, Sopuch A, Rosalba D, Morenghi E, Hernandez G, Monnet X, Cecconi M. Fluid challenge in critically ill patients receiving haemodynamic monitoring: a systematic review and comparison of two decades. Crit Care 2022; 26:186. [PMID: 35729632 PMCID: PMC9210670 DOI: 10.1186/s13054-022-04056-3] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Accepted: 06/07/2022] [Indexed: 11/10/2022] Open
Abstract
Abstract
Introduction
Fluid challenges are widely adopted in critically ill patients to reverse haemodynamic instability. We reviewed the literature to appraise fluid challenge characteristics in intensive care unit (ICU) patients receiving haemodynamic monitoring and considered two decades: 2000–2010 and 2011–2021.
Methods
We assessed research studies and collected data regarding study setting, patient population, fluid challenge characteristics, and monitoring. MEDLINE, Embase, and Cochrane search engines were used. A fluid challenge was defined as an infusion of a definite quantity of fluid (expressed as a volume in mL or ml/kg) in a fixed time (expressed in minutes), whose outcome was defined as a change in predefined haemodynamic variables above a predetermined threshold.
Results
We included 124 studies, 32 (25.8%) published in 2000–2010 and 92 (74.2%) in 2011–2021, overall enrolling 6,086 patients, who presented sepsis/septic shock in 50.6% of cases. The fluid challenge usually consisted of 500 mL (76.6%) of crystalloids (56.6%) infused with a rate of 25 mL/min. Fluid responsiveness was usually defined by a cardiac output/index (CO/CI) increase ≥ 15% (70.9%). The infusion time was quicker (15 min vs 30 min), and crystalloids were more frequent in the 2011–2021 compared to the 2000–2010 period.
Conclusions
In the literature, fluid challenges are usually performed by infusing 500 mL of crystalloids bolus in less than 20 min. A positive fluid challenge response, reported in 52% of ICU patients, is generally defined by a CO/CI increase ≥ 15%. Compared to the 2000–2010 decade, in 2011–2021 the infusion time of the fluid challenge was shorter, and crystalloids were more frequently used.
Collapse
|
4
|
Berg JM, Nielsen DV, Abromaitiene V, Hjørnet NE, Vistisen ST. Changes in arterial blood pressure characteristics following an extrasystolic beat or a fast 50 ml fluid challenge do not predict fluid responsiveness during cardiac surgery. J Clin Monit Comput 2021; 36:889-900. [PMID: 34041648 PMCID: PMC8153528 DOI: 10.1007/s10877-021-00722-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Accepted: 05/18/2021] [Indexed: 11/29/2022]
Abstract
Prediction of fluid responsiveness is essential in perioperative goal directed therapy, but dynamic tests of fluid responsiveness are not applicable during open-chest surgery. We hypothesised that two methods could predict fluid responsiveness during cardiac surgery based on their ability to alter preload and thereby induce changes in arterial blood pressure characteristics: (1) the change caused by extrasystolic beats and (2) the change caused by a fast infusion of 50 ml crystalloid (micro-fluid challenge). Arterial blood pressure and electrocardiogram waveforms were collected during surgical preparation of the left internal mammary artery in patients undergoing coronary artery bypass surgery. Patients received a fluid challenge (5 ml/kg ideal body weight). The first 50 ml were infused in 10 s and comprised the micro-fluid challenge. Predictor variables were defined as post-ectopic beat changes (compared with sinus beats preceding ectopy) in arterial blood pressure characteristics, such as pulse pressure and systolic pressure, or micro-fluid challenge induced changes in the same blood pressure characteristics. Patients were considered fluid responsive if stroke volume index increased by 15% or more after the full fluid challenge. Diagnostic accuracy was calculated by the area under the receiver operating characteristics curve (AUC). Fifty-six patients were included for statistical analysis. Thirty-one had extrasystoles. The maximal AUC was found for the extrasystolic change in pulse pressure and was 0.70 (CI [0.35 to 1.00]). The micro-fluid challenge method generally produced lower AUC point estimates. Extrasystoles did not predict fluid responsiveness with convincing accuracy in patients undergoing cardiac surgery and changes in arterial waveform indices following a micro-fluid challenge could not predict fluid responsiveness. Given a low number of fluid responders and inherently reduced statistical power, our data does not support firm conclusions about the utility of the extrasystolic method. CLINICAL TRIAL REGISTRATION: Unique identifier: NCT02903316. https://clinicaltrials.gov/ct2/show/NCT02903316?cond=NCT02903316&rank=1 .
Collapse
Affiliation(s)
- Jonas M Berg
- Department of Anaesthesia and Intensive Care, Aarhus University Hospital, Pale Juul-Jensens Boulevard 99, building C319, 8200, Aarhus N, Denmark. .,Research Centre for Emergency Medicine, Institute of Clinical Medicine, Aarhus University, Aarhus, Denmark.
| | - Dorthe V Nielsen
- Department of Anaesthesia and Intensive Care, Aarhus University Hospital, Pale Juul-Jensens Boulevard 99, building C319, 8200, Aarhus N, Denmark
| | - Vijoleta Abromaitiene
- Department of Anaesthesia and Intensive Care, Aarhus University Hospital, Pale Juul-Jensens Boulevard 99, building C319, 8200, Aarhus N, Denmark
| | - Niels E Hjørnet
- Department of Anaesthesia and Intensive Care, Aarhus University Hospital, Pale Juul-Jensens Boulevard 99, building C319, 8200, Aarhus N, Denmark
| | - Simon T Vistisen
- Department of Anaesthesia and Intensive Care, Aarhus University Hospital, Pale Juul-Jensens Boulevard 99, building C319, 8200, Aarhus N, Denmark.,Research Centre for Emergency Medicine, Institute of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
5
|
Alvarado Sánchez JI, Caicedo Ruiz JD, Diaztagle Fernández JJ, Amaya Zuñiga WF, Ospina-Tascón GA, Cruz Martínez LE. Predictors of fluid responsiveness in critically ill patients mechanically ventilated at low tidal volumes: systematic review and meta-analysis. Ann Intensive Care 2021; 11:28. [PMID: 33555488 PMCID: PMC7870741 DOI: 10.1186/s13613-021-00817-5] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Accepted: 01/27/2021] [Indexed: 11/13/2022] Open
Abstract
Introduction Dynamic predictors of fluid responsiveness have shown good performance in mechanically ventilated patients at tidal volumes (Vt) > 8 mL kg−1. Nevertheless, most critically ill conditions demand lower Vt. We sought to evaluate the operative performance of several predictors of fluid responsiveness at Vt ≤ 8 mL kg−1 by using meta-regression and subgroup analyses. Methods A sensitive search was conducted in the Embase and MEDLINE databases. We searched for studies prospectively assessing the operative performance of pulse pressure variation (PPV), stroke volume variation (SVV), end-expiratory occlusion test (EEOT), passive leg raising (PLR), inferior vena cava respiratory variability (Δ-IVC), mini-fluid challenge (m-FC), and tidal volume challenge (VtC), to predict fluid responsiveness in adult patients mechanically ventilated at Vt ≤ 8 ml kg−1, without respiratory effort and arrhythmias, published between 1999 and 2020. Operative performance was assessed using hierarchical and bivariate analyses, while subgroup analysis was used to evaluate variations in their operative performance and sources of heterogeneity. A sensitivity analysis based on the methodological quality of the studies included (QUADAS-2) was also performed. Results A total of 33 studies involving 1,352 patients were included for analysis. Areas under the curve (AUC) values for predictors of fluid responsiveness were: for PPV = 0.82, Δ-IVC = 0.86, SVV = 0.90, m-FC = 0.84, PLR = 0.84, EEOT = 0.92, and VtC = 0.92. According to subgroup analyses, variations in methods to measure cardiac output and in turn, to classify patients as responders or non-responders significantly influence the performance of PPV and SVV (p < 0.05). Operative performance of PPV was also significantly affected by the compliance of the respiratory system (p = 0.05), while type of patient (p < 0.01) and thresholds used to determine responsiveness significantly affected the predictability of SVV (p = 0.05). Similarly, volume of fluids infused to determine variation in cardiac output, significantly affected the performance of SVV (p = 0.01) and PLR (p < 0.01). Sensitivity analysis showed no variations in operative performance of PPV (p = 0.39), SVV (p = 0.23) and EEOT (p = 0.15). Conclusion Most predictors of fluid responsiveness reliably predict the response of cardiac output to volume expansion in adult patients mechanically ventilated at tidal volumes ≤ 8 ml kg−1. Nevertheless, technical and clinical variables might clearly influence on their operative performance
Collapse
Affiliation(s)
- Jorge Iván Alvarado Sánchez
- Department of Anaesthesiology, Centro Policlínico del Olaya, Bogotá, Colombia. .,Department of Physiology Sciences, Faculty of Medicine, Universidad Nacional de Colombia, Bogotá, Colombia.
| | - Juan Daniel Caicedo Ruiz
- Department of Physiology Sciences, Faculty of Medicine, Universidad Nacional de Colombia, Bogotá, Colombia
| | - Juan José Diaztagle Fernández
- Department of Physiology Sciences, Faculty of Medicine, Universidad Nacional de Colombia, Bogotá, Colombia.,Fundación Universitaria de Ciencias de La Salud, Bogotá, Colombia.,Department of Internal Medicine, Hospital de San José, Bogotá, Colombia
| | | | | | - Luis Eduardo Cruz Martínez
- Department of Physiology Sciences, Faculty of Medicine, Universidad Nacional de Colombia, Bogotá, Colombia
| |
Collapse
|
6
|
Alvarado Sánchez JI, Caicedo Ruiz JD, Diaztagle Fernández JJ, Amaya Zuñiga WF, Ospina-Tascón GA, Cruz Martínez LE. Predictors of fluid responsiveness in critically ill patients mechanically ventilated at low tidal volumes: systematic review and meta-analysis. Ann Intensive Care 2021. [DOI: https://doi.org/10.1186/s13613-021-00817-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Abstract
Introduction
Dynamic predictors of fluid responsiveness have shown good performance in mechanically ventilated patients at tidal volumes (Vt) > 8 mL kg−1. Nevertheless, most critically ill conditions demand lower Vt. We sought to evaluate the operative performance of several predictors of fluid responsiveness at Vt ≤ 8 mL kg−1 by using meta-regression and subgroup analyses.
Methods
A sensitive search was conducted in the Embase and MEDLINE databases. We searched for studies prospectively assessing the operative performance of pulse pressure variation (PPV), stroke volume variation (SVV), end-expiratory occlusion test (EEOT), passive leg raising (PLR), inferior vena cava respiratory variability (Δ-IVC), mini-fluid challenge (m-FC), and tidal volume challenge (VtC), to predict fluid responsiveness in adult patients mechanically ventilated at Vt ≤ 8 ml kg−1, without respiratory effort and arrhythmias, published between 1999 and 2020. Operative performance was assessed using hierarchical and bivariate analyses, while subgroup analysis was used to evaluate variations in their operative performance and sources of heterogeneity. A sensitivity analysis based on the methodological quality of the studies included (QUADAS-2) was also performed.
Results
A total of 33 studies involving 1,352 patients were included for analysis. Areas under the curve (AUC) values for predictors of fluid responsiveness were: for PPV = 0.82, Δ-IVC = 0.86, SVV = 0.90, m-FC = 0.84, PLR = 0.84, EEOT = 0.92, and VtC = 0.92. According to subgroup analyses, variations in methods to measure cardiac output and in turn, to classify patients as responders or non-responders significantly influence the performance of PPV and SVV (p < 0.05). Operative performance of PPV was also significantly affected by the compliance of the respiratory system (p = 0.05), while type of patient (p < 0.01) and thresholds used to determine responsiveness significantly affected the predictability of SVV (p = 0.05). Similarly, volume of fluids infused to determine variation in cardiac output, significantly affected the performance of SVV (p = 0.01) and PLR (p < 0.01). Sensitivity analysis showed no variations in operative performance of PPV (p = 0.39), SVV (p = 0.23) and EEOT (p = 0.15).
Conclusion
Most predictors of fluid responsiveness reliably predict the response of cardiac output to volume expansion in adult patients mechanically ventilated at tidal volumes ≤ 8 ml kg−1. Nevertheless, technical and clinical variables might clearly influence on their operative performance
Collapse
|
7
|
Schaefer MS, Serpa Neto A, Pelosi P, Gama de Abreu M, Kienbaum P, Schultz MJ, Meyer-Treschan TA. Temporal Changes in Ventilator Settings in Patients With Uninjured Lungs: A Systematic Review. Anesth Analg 2020; 129:129-140. [PMID: 30222649 DOI: 10.1213/ane.0000000000003758] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
In patients with uninjured lungs, increasing evidence indicates that tidal volume (VT) reduction improves outcomes in the intensive care unit (ICU) and in the operating room (OR). However, the degree to which this evidence has translated to clinical changes in ventilator settings for patients with uninjured lungs is unknown. To clarify whether ventilator settings have changed, we searched MEDLINE, Cochrane Central Register of Controlled Trials, and Web of Science for publications on invasive ventilation in ICUs or ORs, excluding those on patients <18 years of age or those with >25% of patients with acute respiratory distress syndrome (ARDS). Our primary end point was temporal change in VT over time. Secondary end points were changes in maximum airway pressure, mean airway pressure, positive end-expiratory pressure, inspiratory oxygen fraction, development of ARDS (ICU studies only), and postoperative pulmonary complications (OR studies only) determined using correlation analysis and linear regression. We identified 96 ICU and 96 OR studies comprising 130,316 patients from 1975 to 2014 and observed that in the ICU, VT size decreased annually by 0.16 mL/kg (-0.19 to -0.12 mL/kg) (P < .001), while positive end-expiratory pressure increased by an average of 0.1 mbar/y (0.02-0.17 mbar/y) (P = .017). In the OR, VT size decreased by 0.09 mL/kg per year (-0.14 to -0.04 mL/kg per year) (P < .001). The change in VTs leveled off in 1995. Other intraoperative ventilator settings did not change in the study period. Incidences of ARDS (ICU studies) and postoperative pulmonary complications (OR studies) also did not change over time. We found that, during a 39-year period, from 1975 to 2014, VTs in clinical studies on mechanical ventilation have decreased significantly in the ICU and in the OR.
Collapse
Affiliation(s)
- Maximilian S Schaefer
- From the Department of Anesthesiology, Düsseldorf University Hospital, Düsseldorf, Germany
| | - Ary Serpa Neto
- Department of Critical Care Medicine, Hospital Israelita Albert Einstein, São Paulo, Brazil.,Program of Post-Graduation, Innovation and Research, Faculdade de Medicina do ABC, Santo Andre, Brazil
| | - Paolo Pelosi
- Department of Surgical Sciences and Integrated Diagnostics, San Martino Policlinico Hospital, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) for Oncology, Genoa, Italy
| | - Marcelo Gama de Abreu
- Department of Anesthesiology and Intensive Care Therapy, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Dresden, Germany
| | - Peter Kienbaum
- From the Department of Anesthesiology, Düsseldorf University Hospital, Düsseldorf, Germany
| | - Marcus J Schultz
- Department of Intensive Care, Academic Medical Center, University of Amsterdam, the Netherlands
| | | |
Collapse
|
8
|
Vistisen ST, Berg JM, Boekel MF, Modestini M, Bergman R, Jainandunsing JS, Mariani MA, Scheeren TWL. Using extra systoles and the micro-fluid challenge to predict fluid responsiveness during cardiac surgery. J Clin Monit Comput 2018; 33:777-786. [PMID: 30414054 DOI: 10.1007/s10877-018-0218-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Accepted: 11/01/2018] [Indexed: 11/28/2022]
Abstract
Fluid responsiveness prediction is difficult during cardiac surgery. The micro-fluid challenge (micro-FC; rapid central infusion of 50 ml) and the extrasystolic method utilising post-extrasystolic preload increases may predict fluid responsiveness. Two study windows during coronary artery bypass graft surgery were defined, 1: After anaesthesia induction until surgical incision, 2: Left internal mammarian artery surgical preparation period. Each window consisted of 10-15 min observation for extrasystoles before a micro-FC was performed, after which a traditional fluid challenge (FC) was performed (5 ml/kg). Extrasystolic and micro-FC induced changes in hemodynamic variables were derived as predictors of fluid responsiveness defined as stroke volume increasing > 10% following FC. 61 patients were studied. Post-ectopic changes in pulse pressure (PP) predicted fluid responsiveness with receiver operating characteristic area (AUC) of 0.69 [CI 0.40;0.97] in the first study window and 0.64 [0.44;0.86] in the second window. Other post-ectopic predictors such as pre-ejection period (PEP) and systolic blood pressure (SBP) had similar or lower AUCs. Heart rate was 52.9 (SD ±8.4) min- 1 and 53.6 (± 8.8) min- 1 in the two study windows. Micro-FC induced changes in PEP had AUC of 0.74 [0.57;0.90] in the first window and 0.60 [0.40;0.76] in the second window. Correcting micro-FC induced changes in PEP for the micro-FC induced changes in heart rate had AUCs of 0.84 [0.70;0.97] in the first window and 0.63 [0.47;0.79] in the second window. The investigated methods revealed insufficient validity during cardiac surgery. RR interval corrected changes during a micro-FC should be investigated further. Trial registration Clinicaltrials.gov: NCT03002129.
Collapse
Affiliation(s)
- Simon T Vistisen
- Research Centre for Emergency Medicine, Aarhus University, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark. .,Department of Anaesthesiology and Intensive Care, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark. .,Department of Anaesthesiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, P.O.Box 30.001, 9700 RB, Groningen, The Netherlands.
| | - Jonas M Berg
- Research Centre for Emergency Medicine, Aarhus University, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark.,Department of Anaesthesiology and Intensive Care, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
| | - Mattheus F Boekel
- Department of Anaesthesiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, P.O.Box 30.001, 9700 RB, Groningen, The Netherlands
| | - Marco Modestini
- Department of Anaesthesiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, P.O.Box 30.001, 9700 RB, Groningen, The Netherlands
| | - Remco Bergman
- Department of Anaesthesiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, P.O.Box 30.001, 9700 RB, Groningen, The Netherlands
| | - Jayant S Jainandunsing
- Department of Anaesthesiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, P.O.Box 30.001, 9700 RB, Groningen, The Netherlands
| | - Massimo A Mariani
- Department of Cardio-Thoracic Surgery, University of Groningen, University Medical Center Groningen, Hanzeplein 1, P.O.Box 30.001, 9700 RB, Groningen, The Netherlands
| | - Thomas W L Scheeren
- Department of Anaesthesiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, P.O.Box 30.001, 9700 RB, Groningen, The Netherlands
| |
Collapse
|
9
|
|
10
|
Toscani L, Aya HD, Antonakaki D, Bastoni D, Watson X, Arulkumaran N, Rhodes A, Cecconi M. What is the impact of the fluid challenge technique on diagnosis of fluid responsiveness? A systematic review and meta-analysis. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2017; 21:207. [PMID: 28774325 PMCID: PMC5543539 DOI: 10.1186/s13054-017-1796-9] [Citation(s) in RCA: 65] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/27/2017] [Accepted: 07/12/2017] [Indexed: 12/21/2022]
Abstract
Background The fluid challenge is considered the gold standard for diagnosis of fluid responsiveness. The objective of this study was to describe the fluid challenge techniques reported in fluid responsiveness studies and to assess the difference in the proportion of ‘responders,’ (PR) depending on the type of fluid, volume, duration of infusion and timing of assessment. Methods Searches of MEDLINE and Embase were performed for studies using the fluid challenge as a test of cardiac preload with a description of the technique, a reported definition of fluid responsiveness and PR. The primary outcome was the mean PR, depending on volume of fluid, type of fluids, rate of infusion and time of assessment. Results A total of 85 studies (3601 patients) were included in the analysis. The PR were 54.4% (95% CI 46.9–62.7) where <500 ml was administered, 57.2% (95% CI 52.9–61.0) where 500 ml was administered and 60.5% (95% CI 35.9–79.2) where >500 ml was administered (p = 0.71). The PR was not affected by type of fluid. The PR was similar among patients administered a fluid challenge for <15 minutes (59.2%, 95% CI 54.2–64.1) and for 15–30 minutes (57.7%, 95% CI 52.4–62.4, p = 1). Where the infusion time was ≥30 minutes, there was a lower PR of 49.9% (95% CI 45.6–54, p = 0.04). Response was assessed at the end of fluid challenge, between 1 and 10 minutes, and >10 minutes after the fluid challenge. The proportions of responders were 53.9%, 57.7% and 52.3%, respectively (p = 0.47). Conclusions The PR decreases with a long infusion time. A standard technique for fluid challenge is desirable. Electronic supplementary material The online version of this article (doi:10.1186/s13054-017-1796-9) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Laura Toscani
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK.,Cristo Re Hospital, Via delle Calasanziane 25, 00167, Rome, Italy
| | - Hollmann D Aya
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK. .,Anaesthetic Department, East Surrey Hospital, Surrey & Sussex Healthcare Trust, Canada Avenue, Redhill, Surrey, RH1 5 RH, UK.
| | - Dimitra Antonakaki
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK.,Cardiology Department, Broomfield Hospital, Mid-Essex Healthcare Trust, Court Road, Broomfield, Chelmsford, CM1 7ET, UK
| | - Davide Bastoni
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK.,Dipartimento di Medicina Sperimentale, Azienda Ospedaliero-Universitaria di Parma, Via Gramsci 14, 43126, Parma, Italy
| | - Ximena Watson
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK
| | - Nish Arulkumaran
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK
| | - Andrew Rhodes
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK
| | - Maurizio Cecconi
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK
| |
Collapse
|
11
|
Vistisen ST. Using extra systoles to predict fluid responsiveness in cardiothoracic critical care patients. J Clin Monit Comput 2016; 31:693-699. [PMID: 27460129 DOI: 10.1007/s10877-016-9907-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2016] [Accepted: 07/11/2016] [Indexed: 12/22/2022]
Abstract
Fluid responsiveness prediction is an unsettled matter for most critical care patients and new methods relying only on the continuous basic monitoring are desired. It was hypothesized that the post-ectopic beat, which is associated with increased preload, could be analyzed in relation to preceding sinus beats and that the change in cardiac performance (e.g. systolic blood pressure) at the post-ectopic beat could predict fluid responsiveness. Cardiothoracic critical care patients scheduled for a 500 ml volume expansion were observed. In the 30 min prior to volume expansion, the ECG was analyzed for occurrence of extra systoles preceded by at least 10 sinus beats. Classification variables, were defined as the change in a variable (e.g. systolic blood pressure or pre-ejection period) from the median of 10 preceding sinus beats to extra systolic post-ectopic beat. A stroke volume increase >15 % following volume expansion defined fluid responsiveness. Thirty patients were included. The change in systolic blood pressure predicted fluid responsiveness in 24 patients correctly with 83 % specificity and 75 % sensitivity (optimal threshold: 5 % systolic blood pressure increase), receiver operating characteristic (ROC) area: 0.81 (CI [0.64;0.98]). The change in pre-ejection period predicted fluid responsiveness in 22 patients correctly with 67 % specificity and 83 % sensitivity (optimal threshold: 19 ms pre-ejection period decrease), ROC area: 0.81 (CI [0.66;0.96]). Pulse pressure variation had ROC area of 0.57 (CI [0.39;0.75]). Based on standard critical care monitoring, analysis of the extra systolic post-ectopic beat predicts fluid responsiveness in cardiothoracic critical care patients with good accuracy.
Collapse
Affiliation(s)
- Simon Tilma Vistisen
- Research Centre for Emergency Medicine, Aarhus University, Nørrebrogade 44, Building 30, 1st floor, 8000, Aarhus C, Denmark.
| |
Collapse
|
12
|
Marx G, Schindler AW, Mosch C, Albers J, Bauer M, Gnass I, Hobohm C, Janssens U, Kluge S, Kranke P, Maurer T, Merz W, Neugebauer E, Quintel M, Senninger N, Trampisch HJ, Waydhas C, Wildenauer R, Zacharowski K, Eikermann M. Intravascular volume therapy in adults: Guidelines from the Association of the Scientific Medical Societies in Germany. Eur J Anaesthesiol 2016; 33:488-521. [PMID: 27043493 PMCID: PMC4890839 DOI: 10.1097/eja.0000000000000447] [Citation(s) in RCA: 60] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Gernot Marx
- From the Department of Cardiothoracic and Vascular Surgery, University Medical Centre of the Johannes Gutenberg University Mainz, Mainz (JA); Department of Anaesthesiology and Intensive Care Medicine, Jena University Hospital, Jena (MB); Institute for Research in Operative Medicine, Witten/Herdecke University, Cologne (ME); Institute of Nursing Science and Practice, Paracelsus Private Medical University, Salzburg, Austria (IG); Department of Internal Medicine, Neurology and Dermatology, Leipzig University Hospital, Leibzig (CH); Department of Cardiology, St Antonius Hospital, Eschweiler (UJ); Centre for Intensive Care Medicine, Universitätsklinikum, Hamburg-Eppendorf (SK); Department of Anaesthesia and Critical Care, University Hospital of Würzburg, Würzburg (PK); Department of Intensive and Intermediate Care Medicine, University Hospital of RWTH Aachen, Aachen (GM); Urological Unit and Outpatient Clinic, University Hospital rechts der Isar, Munich (TM); Department of Obstetrics and Gynaecology, Bonn University Hospital, Bonn (WM); Institute for Research in Operative Medicine (IFOM), Witten/Herdecke University, Cologne (CM, EN); Department of Anaesthesiology, University Medical Centre Göttingen, Göttingen (MQ); Department of Intensive and Intermediate Care Medicine, University Hospital of RWTH Aachen, Aachen (AWS); Department of General and Visceral Surgery, Münster University Hospital, Münster (NS); Department of Health Informatics, Biometry and Epidemiology, Ruhr-Universität Bochum, Bochum (HJT); Department of Trauma Surgery, Essen University Hospital, Essen (CW); Department of General Surgery, University Hospital of Würzburg, Würzburg (RW); and Department of Anaesthesia, Intensive Care Medicine and Pain Therapy, University Hospital Frankfurt, Frankfurt, Germany (KZ)
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Kawazoe Y, Nakashima T, Iseri T, Yonetani C, Ueda K, Fujimoto Y, Kato S. The impact of inspiratory pressure on stroke volume variation and the evaluation of indexing stroke volume variation to inspiratory pressure under various preload conditions in experimental animals. J Anesth 2015; 29:515-21. [PMID: 25771761 PMCID: PMC4543412 DOI: 10.1007/s00540-015-1995-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2014] [Accepted: 02/26/2015] [Indexed: 12/29/2022]
Abstract
PURPOSE Stroke volume variation (SVV) measures fluid responsiveness, enabling optimal fluid management under positive pressure ventilation. We aimed to investigate the effect of peak inspiratory pressure (PIP) on SVV under various preload conditions in experimental animals and to ascertain whether SVV indexed to PIP decreases the effect. METHODS Mild and moderate hemorrhage models were created in nine anesthetized, mechanically ventilated beagle dogs by sequentially removing 10 and then an additional 10 ml/kg of blood, respectively. In all the animals, PIP was incrementally increased by 4 cmH2O, from 5 to 21 cmH2O. SVV was measured by arterial pulse contour analysis. Stroke volume was derived using a thermodilution method, and central venous pressure and mean arterial pressure were also measured. RESULTS SVV increased according to PIP with significant correlation at baseline, with mild hemorrhage and moderate hemorrhage. PIP regression coefficients at baseline and in the mild and moderate hemorrhage models were 0.59, 0.86, and 1.4, respectively. Two-way repeated-measures analysis of variance showed that PIP and the degree of hemorrhage had a significant interaction effect on SVV (p = 0.0016). SVV indexed to PIP reflected the hemorrhage status regardless of PIP changes ≥9 cmH2O. CONCLUSIONS PIP is significantly correlated with SVV, even under hypovolemia, and the effect is enhanced with decreasing preload volumes. Compared with SVV, the indexed SVV was less susceptible to higher inspiratory pressures.
Collapse
Affiliation(s)
- Yu Kawazoe
- Department of Emergency and Critical Care Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama, 641-8510, Japan,
| | | | | | | | | | | | | |
Collapse
|
14
|
Yang X, Du B. Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2014; 18:650. [PMID: 25427970 PMCID: PMC4258282 DOI: 10.1186/s13054-014-0650-6] [Citation(s) in RCA: 148] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2014] [Accepted: 11/06/2014] [Indexed: 02/08/2023]
Abstract
Introduction Fluid resuscitation is crucial in managing hemodynamically unstable patients. The last decade witnessed the use of pulse pressure variation (PPV) to predict fluid responsiveness. However, as far as we know, no systematic review and meta-analysis has been carried out to evaluate the value of PPV in predicting fluid responsiveness specifically upon patients admitted into intensive care units. Methods We searched MEDLINE and EMBASE and included clinical trials that evaluated the association between PPV and fluid responsiveness after fluid challenge in mechanically ventilated patients in intensive care units. Data were synthesized using an exact binomial rendition of the bivariate mixed-effects regression model modified for synthesis of diagnostic test data. Result Twenty-two studies with 807 mechanically ventilated patients with tidal volume more than 8 ml/kg and without spontaneous breathing and cardiac arrhythmia were included, and 465 were responders (58%). The pooled sensitivity was 0.88 (95% confidence interval (CI) 0.81 to 0.92) and pooled specificity was 0.89 (95% CI 0.84 to 0.92). A summary receiver operating characteristic curve yielded an area under the curve of 0.94 (95% CI 0.91 to 0.95). A significant threshold effect was identified. Conclusions PPV predicts fluid responsiveness accurately in mechanically ventilated patients with relative large tidal volume and without spontaneous breathing and cardiac arrhythmia. Electronic supplementary material The online version of this article (doi:10.1186/s13054-014-0650-6) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Xiaobo Yang
- Medical ICU, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, 1 Shuai Fu Yuan, Beijing, 100730, PR China.
| | - Bin Du
- Medical ICU, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, 1 Shuai Fu Yuan, Beijing, 100730, PR China.
| |
Collapse
|
15
|
van Houwelingen MJ, Merkus D, Hofland J, Bakker J, Tenbrinck R, Te Lintel Hekkert M, van Dijk G, Hoeks APG, Duncker DJ. A novel approach to assess hemorrhagic shock severity using the arterially determined left ventricular isovolumic contraction period. Am J Physiol Heart Circ Physiol 2013; 305:H1790-7. [PMID: 24124184 DOI: 10.1152/ajpheart.00504.2013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Recently, the ventilatory variation in pre-ejection period (ΔPEP) was found to be useful in the prediction of fluid-responsiveness of patients in shock. In the present study we investigated the behavior of the ventilation-induced variations in the systolic timing intervals in response to a graded hemorrhage protocol. The timing intervals studied included the ventilatory variation in ventricular electromechanical delay (ΔEMD), isovolumic contraction period (determined from the arterial pressure waveform, ΔAIC), pulse travel time (ΔPTT), and ΔPEP. ΔAIC and ΔPEP were evaluated in the aorta and carotid artery (annotated by subscripts Ao and CA) and were compared with the responses of pulse pressure variation (ΔPPAo) and stroke volume variation (ΔSV). The graded hemorrhage protocol, followed by resuscitation using norepinephrine and autologous blood transfusion, was performed in eight anesthetized Yorkshire X Landrace swine. ΔAICAo, ΔAICCA, ΔPEPAo, ΔPEPCA, ΔPPAo, ΔPPCA, and ΔSV showed significant increases during the graded hemorrhage and significant decreases during the subsequent resuscitation. ΔAICAo, ΔAICCA, ΔPEPAo, and ΔPEPCA all correlated well with ΔPPAo and ΔSV (all r ≥ 0.8, all P < 0.001). ΔEMD and ΔPTT did not significantly change throughout the protocol. In contrast with ΔPEPAo, which was significantly higher than ΔPEPCA (P < 0.01), ΔAICAo was not different from ΔAICCA. In conclusion, ventilation-induced preload variation principally affects the arterially determined isovolumic contraction period (AIC). Moreover, ΔAIC can be determined solely from the arterial pressure waveform, whereas ΔPEP also requires ECG measurement. Importantly, ΔAIC determined from either the carotid or aortic pressure waveform are interchangeable, suggesting that, in contrast with ΔPEP, ΔAIC may be site independent.
Collapse
Affiliation(s)
- Marc J van Houwelingen
- Experimental Cardiology, Thoraxcenter, Cardiovascular Research Institute, Cardiovascular Research School Erasmus University Rotterdam, Erasmus University Medical Center, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Vistisen ST, Andersen KK, Frederiksen CA, Kirkegaard H. Variations in the pre-ejection period induced by ventricular extra systoles may be feasible to predict fluid responsiveness. J Clin Monit Comput 2013; 28:341-9. [PMID: 24203263 DOI: 10.1007/s10877-013-9528-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2013] [Accepted: 10/31/2013] [Indexed: 11/28/2022]
Abstract
Monitoring that can predict fluid responsiveness is an unsettled matter for spontaneously breathing patients. Based on the convincing results with dynamic monitoring based on preload variations induced by mechanical ventilation, we hypothesised that the extra systolic post-ectopic beat could constitute a similar intermittent preload shift inducing a brief variation in blood pressure and that the magnitude of this variation could predict the hemodynamic response to volume expansion in sedated pigs. Ten pigs were sedated and hemodynamically monitored and four intravascular volume shifts were made: blood depletion (25% of estimated blood volume; 660 ml), retransfusion (of 500 ml depleted blood), and two sequential volume expansions (500 ml colloid each). Between volume shifts, supraventricular and ventricular extra systoles were induced by a pacemaker. Hemodynamic variables such as pulse pressure (PP) and pre-ejection period (PEP) were determined for each heart beat and the hemodynamic changes in the post-ectopic beats compared to sinus beats was extracted (e.g. ∆PP and ∆PEP) and used to predict fluid responsiveness of subsequent volume expansions which was determined by receiver operating characteristic (ROC) curves. Ventricular extra systoles were generally useful for fluid responsiveness prediction (ROC areas >0.65). ∆PEP variables best predicted fluid responsiveness: ∆PEP derived from arterial pressure curve and ECG had ROC area of 0.84 and sensitivity of 0.77 and specificity of 0.71; ∆PEP derived from plethysmographic curve and ECG had ROC area of 0.79 and sensitivity of 0.71 and specificity of 0.70. However, ∆PP was not a useful variable in this study (ROC area <0.65). Hemodynamic analysis of post ectopic beats may be a feasible method for fluid responsiveness prediction.
Collapse
Affiliation(s)
- Simon Tilma Vistisen
- Research Centre for Emergency Medicine, Institute of Clinical Medicine, Aarhus University, Nørrebrogade 44, Building 30, 1st Floor, 8000, Århus C, Denmark,
| | | | | | | |
Collapse
|
17
|
Vistisen ST, Juhl-Olsen P, Frederiksen CA, Kirkegaard H. Variations in the pre-ejection period induced by deep breathing do not predict the hemodynamic response to early haemorrhage in healthy volunteers. J Clin Monit Comput 2013; 28:233-41. [DOI: 10.1007/s10877-013-9526-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2013] [Accepted: 10/24/2013] [Indexed: 11/24/2022]
|
18
|
Smorenberg A, Lust EJ, Beishuizen A, Meijer JH, Verdaasdonk RM, Groeneveld ABJ. Systolic time intervals vs invasive predictors of fluid responsiveness after coronary artery bypass surgery. Eur J Cardiothorac Surg 2013; 44:891-7. [PMID: 23475589 DOI: 10.1093/ejcts/ezt108] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
OBJECTIVES Haemodynamic parameters for predicting fluid responsiveness in intensive care patients are invasive, technically challenging or not universally applicable. We compared the initial systolic time interval (ISTI), a non-invasive measure of the time interval between the electrical and mechanical activities of the heart measured by impedance cardiography, with invasively measured haemodynamic parameters in predicting fluid responsiveness after cardiac surgery. METHODS Thirty-two clinically hypovolemic patients admitted to the intensive care unit after coronary artery bypass surgery received 500 ml of gelatine solution in two volume loading steps of 250 ml at an infusion rate of 1000 ml/h. Haemodynamic and biochemical measurements were done at baseline and 15 min after each volume loading step with continuous recording of the impedance cardiogram and electrocardiogram. RESULTS Forty-four percentage (n = 14) of patients showed a stroke volume (SV) index increase >10%. ISTI predicted fluid responsiveness with an optimum threshold of >153 ms (P = 0.023) and a sensitivity of 71% and specificity of 78%. The predictive values of ISTI did not differ from those of arterial pressure or SV at baseline. A decrease of ISTI of ≥8.3 ms predicted fluid responsiveness with the highest positive predictive value (88%, P = 0.004) among the variables, and absence thereof virtually excluded fluid responsiveness (specificity 94%). CONCLUSIONS Non-invasively measured ISTI is able to predict and monitor fluid responsiveness after cardiac surgery non-inferiorly to invasively measured haemodynamic indices.
Collapse
Affiliation(s)
- Annemieke Smorenberg
- Department of Intensive Care, VU University Medical Center, Amsterdam, Netherlands
| | | | | | | | | | | |
Collapse
|
19
|
Lansdorp B, Lemson J, van Putten M, de Keijzer A, van der Hoeven J, Pickkers P. Dynamic indices do not predict volume responsiveness in routine clinical practice. Br J Anaesth 2012; 108:395-401. [DOI: 10.1093/bja/aer411] [Citation(s) in RCA: 101] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
|
20
|
Giraud R, Siegenthaler N, Morel DR, Bendjelid K. Pre-ejection period to estimate cardiac preload dependency in mechanically ventilated pigs submitted to severe hemorrhagic shock. ACTA ACUST UNITED AC 2012; 71:702-7. [PMID: 21378580 DOI: 10.1097/ta.0b013e3181f96823] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Respiratory change in pre-ejection period (ΔPEP) has been described as a potential parameter for monitoring cardiac preload dependency in critically ill patients. This study was designed to describe the relationship between ΔPEP and pulse pressure variation (PPV) in pigs submitted to severe hemorrhagic shock. METHODS In 17 paralyzed, anesthetized mechanically ventilated pigs, electrocardiography, arterial pressure, and cardiac output derived from pulmonary artery catheter were recorded. Hemorrhagic shock was induced by removal of blood volume followed by restoration. PEP was defined as the time interval between the beginning of the Q wave on the electrocardiogram and the upstroke of the invasive radial arterial pressure curve. RESULTS At baseline, ΔPEP and PPVs were both <12% with PPV significantly correlated with ΔPEP (r = 0.96, p < 0.001). Volume loss induced by hemorrhage significantly increased PPV and ΔPEP values (p < 0.05). During severe hemorrhage, PPV correlated well with ΔPEP (r = 0.88, p < 0.001) with PPV values significantly higher than ΔPEP (p < 0.05). However, the reproducibility of ΔPEP measurements was significantly better than PPV during this step (p < 0.05). Retransfusion significantly decreased PPV and ΔPEP (p < 0.05) with PPV significantly correlated to ΔPEP (r = 0.94, p < 0.001). CONCLUSION Available correlations between PPV and ΔPEP at each time of the study were observed, meaning that ΔPEP is a reliable parameter to estimate and track the changes in cardiac preload dependency. Moreover, during the severe hemorrhagic shock period, ΔPEP measurements were more reproducible than PPV values.
Collapse
Affiliation(s)
- Raphael Giraud
- Intensive Care Unit, Geneva University Hospitals, Geneva, Switzerland
| | | | | | | |
Collapse
|
21
|
Vistisen ST, Koefoed-Nielsen J, Larsson A. Should dynamic parameters for prediction of fluid responsiveness be indexed to the tidal volume? Acta Anaesthesiol Scand 2010; 54:191-8. [PMID: 19764908 DOI: 10.1111/j.1399-6576.2009.02114.x] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
BACKGROUND The respiratory variation in the pre-ejection period (Delta PEP) has been used to predict fluid responsiveness in mechanically ventilated patients. Recently, we modified this parameter (PEPV) and showed that it was a reliable predictor for post-cardiac surgery, mainly paced, patients when moderately low tidal volumes were used. One of the modifications involved tidal volume indexation, which had not been proposed before for dynamic parameters. The aim of the present animal study was to investigate whether indexation to tidal volume should be part of a new definition of dynamic parameters such as the case for our newly proposed PEPV. METHODS Eight prone, anesthetized piglets (23-27 kg) were subjected to a sequence of 25% hypovolemia, normovolemia, and 25% and 50% hypervolemia. At each volemic level, tidal volumes were varied in three steps: 6, 9, and 12 ml/kg. PEP variations (ms) and pulse-pressure variation (PPV) were measured during the three tidal volume steps at each volemic level. RESULTS PEP variations increased significantly with increasing tidal volume at all volemic levels but 50% hypervolemia and were proportionally related to the tidal volume at normovolemia. PPV increased significantly with increasing tidal volume at all volemic levels and was roughly proportional to the tidal volume at all volemic levels but hypovolemia. CONCLUSION Our study indicates that dynamic parameters are improved by indexing to tidal volume.
Collapse
Affiliation(s)
- S T Vistisen
- Aalborg Hospital, Part of Aarhus University Hospital, Aalborg, Denmark.
| | | | | |
Collapse
|
22
|
Vistisen ST, Koefoed-Nielsen J, Larsson A. Automated pre-ejection period variation predicts fluid responsiveness in low tidal volume ventilated pigs. Acta Anaesthesiol Scand 2010; 54:199-205. [PMID: 19681786 DOI: 10.1111/j.1399-6576.2009.02061.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
INTRODUCTION The respiratory variation in the pre-ejection period (Delta PEP) has been used to predict fluid responsiveness in mechanically ventilated patients. Recently, we automated this parameter and indexed it to tidal volume (PEPV) and showed that it was a reliable predictor for post-cardiac surgery, mainly paced, patients ventilated with low tidal volumes. The aims of the present animal study were to investigate PEPV's ability to predict fluid responsiveness under different fluid loading conditions and natural heart rates during low tidal volume ventilation (6 ml/kg) and to compare the performance of PEPV with other markers of fluid responsiveness. METHODS Eight prone, anesthetized piglets (23-27 kg) ventilated with tidal volumes of 6 ml/kg were subjected to a sequence of 25% hypovolemia, normovolemia, and 25% and 50% hypervolemia. PEPV, Delta PEP, pulse pressure variation (PPV), central venous pressure (CVP), and pulmonary artery occlusion pressure (PAOP) were measured before each volume expansion. RESULTS Sensitivity was 89% and specificity was 93% for PEPV, 78% and 93% for Delta PEP, 89% and 100% for PPV, 78% and 93% for CVP, and 89% and 87% for PAOP. CONCLUSION PEPV predicts fluid responsiveness in low tidal volume ventilated piglets.
Collapse
Affiliation(s)
- S T Vistisen
- Aalborg Hospital, Aarhus University Hospital, Aalborg, Denmark.
| | | | | |
Collapse
|
23
|
Lansdorp B, van den Brule JMD, van der Hoeven JG, Pickkers P. The influence of pacing on the pre-ejection period. Acta Anaesthesiol Scand 2010; 54:123; author reply 123-4. [PMID: 19961447 DOI: 10.1111/j.1399-6576.2009.02063.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
24
|
Vistisen ST, Struijk JJ, Larsson A. Reply. Acta Anaesthesiol Scand 2010. [DOI: 10.1111/j.1399-6576.2009.02065.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|