1
|
Andriollo L, Fravolini G, Sangaletti R, Perticarini L, Benazzo F, Rossi SMP. Angle-Adjustable Dynamic Hip Screw Plate for Unstable Trochanteric Fractures in Middle-Aged Patients: Mid-Term Outcomes and Return to Sport. J Clin Med 2024; 13:988. [PMID: 38398302 PMCID: PMC10889291 DOI: 10.3390/jcm13040988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Revised: 02/02/2024] [Accepted: 02/07/2024] [Indexed: 02/25/2024] Open
Abstract
BACKGROUND There are conflicting results in the literature regarding the superiority of proximal femoral nails over dynamic hip screw (DHS) plates. The primary aim of this study is to evaluate mid-term post-injury patient-reported outcome measures (PROMs) and return to sport (RTS) in middle-aged patients treated with the DHS plate for unstable trochanteric fractures. METHODS Fifty-seven middle-aged patients (35-64 years) treated for proximal femoral fractures of type 31-A2 and 31-A3 according to the AO/OTA classification with the DMS Dynamic Martin Screw (KLS Martin Group, Jacksonville, FL, USA) between January 2017 and December 2019 were enrolled. RESULTS Forty-nine patients were included in this retrospective study, and the average age was 54.1 years (SD 8.4). The average follow-up duration at final follow-up was 60.5 months (SD 8.6). Post-operative complications included only one case of aseptic loosening of the implant, with a complication rate of 2%. There were no infections, peri-implant fractures, or other complications reported. Two out of the forty-nine patients (4.1%) required treatment with a total hip arthroplasty due to post-traumatic arthritis. The Harris Hip Score at final follow-up was 77.1 (SD 20.1), and the Western Ontario and McMaster Universities Osteoarthritis Index was 21.6 (SD 13.7). The overall rate of RTS was 57.7%. CONCLUSIONS Treatment with DHS for unstable trochanteric fractures is a safe option in middle-aged patients, ensuring a good functional recovery.
Collapse
Affiliation(s)
- Luca Andriollo
- Robotic Prosthetic Surgery Unit—Sports Traumatology Unit, Fondazione Poliambulanza Istituto Ospedaliero, 25124 Brescia, Italy; (L.A.); (G.F.); (R.S.); (L.P.); (F.B.)
- Department of Orthopedics, Catholic University of the Sacred Heart, 00168 Rome, Italy
| | - Giorgio Fravolini
- Robotic Prosthetic Surgery Unit—Sports Traumatology Unit, Fondazione Poliambulanza Istituto Ospedaliero, 25124 Brescia, Italy; (L.A.); (G.F.); (R.S.); (L.P.); (F.B.)
- Department of Orthopedics, Catholic University of the Sacred Heart, 00168 Rome, Italy
| | - Rudy Sangaletti
- Robotic Prosthetic Surgery Unit—Sports Traumatology Unit, Fondazione Poliambulanza Istituto Ospedaliero, 25124 Brescia, Italy; (L.A.); (G.F.); (R.S.); (L.P.); (F.B.)
| | - Loris Perticarini
- Robotic Prosthetic Surgery Unit—Sports Traumatology Unit, Fondazione Poliambulanza Istituto Ospedaliero, 25124 Brescia, Italy; (L.A.); (G.F.); (R.S.); (L.P.); (F.B.)
| | - Francesco Benazzo
- Robotic Prosthetic Surgery Unit—Sports Traumatology Unit, Fondazione Poliambulanza Istituto Ospedaliero, 25124 Brescia, Italy; (L.A.); (G.F.); (R.S.); (L.P.); (F.B.)
- Biomedical Sciences Area, IUSS University School for Advanced Studies, 27100 Pavia, Italy
| | - Stefano Marco Paolo Rossi
- Robotic Prosthetic Surgery Unit—Sports Traumatology Unit, Fondazione Poliambulanza Istituto Ospedaliero, 25124 Brescia, Italy; (L.A.); (G.F.); (R.S.); (L.P.); (F.B.)
| |
Collapse
|
2
|
Lim ZZC, Tan CMP, Antony Xavier RP, Yam MGJ, Chua ITH. Femoral neck system as a safe alternative to cannulated compression screw and dynamic hip screw in femoral neck fractures: an early comparative study. Singapore Med J 2024:00077293-990000000-00072. [PMID: 38421148 DOI: 10.4103/singaporemedj.smj-2022-024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Accepted: 06/02/2022] [Indexed: 03/02/2024]
Abstract
INTRODUCTION The femoral neck system (FNS) is a safe alternative to cannulated compression screw (CCS) and dynamic hip screw (DHS) in femoral neck fractures. METHODS A dual-centre retrospective cohort study was performed on femoral neck fractures (AO type 31-B) treated with closed reduction and internal fixation using FNS, DHS or CCS between April 2016 and April 2020. Exclusion criteria were as follows: patients aged below 16 years; chronic fractures beyond 7 days; pathological fractures; fracture extension to the intertrochanteric region or ipsilateral neck and shaft fractures; and open fractures. A total of 85 patients were identified: FNS (n = 28), DHS (n = 29) and CCS (n = 28). RESULTS The FNS and CCS groups had a lower Garden and Pauwels classification compared to the DHS group (both P < 0.001). Both FNS and CCS groups were comparable in postoperative orthopaedic complications (10.7% [n = 3] vs. 3.6% [n = 1], adjusted P = 0.321). The DHS group had more postoperative orthopaedic complications than the FNS group, but this was not statistically significant (27.6% [n = 8] vs. 10.7% [n = 3], adjusted P = 0.321). There were no significant differences in median time to radiological union or median femoral neck shortening at union (both P > 0.05) among the three groups. CONCLUSION The new DePuy Synthes FNS is a safe alternative to CCS with comparable complication rates for femoral neck fractures that are less displaced and more stable. The FNS also appears to be a safe alternative to DHS in the fixation of femoral neck fractures for the few cases of high-energy femoral neck fractures.
Collapse
|
3
|
Kumar J, Symonds T, Quinn J, Walsh T, Platt S. What is the best method of fixation for minimally displaced subcapital neck of femur fractures? A systematic review. J Orthop 2023; 45:54-60. [PMID: 37854276 PMCID: PMC10579867 DOI: 10.1016/j.jor.2023.09.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 07/26/2023] [Accepted: 09/29/2023] [Indexed: 10/20/2023] Open
Abstract
BACKGROUND Femoral neck fractures are a common cause of morbidity and mortality in the community. Minimally displaced subcapital necks of femoral fractures are usually managed with internal fixation, although there is debate as to which method is superior. This systematic review aimed to compare the outcomes of different fixation methods in the management of this common fracture. METHODS This systematic review was conducted in accordance with PRISMA statement guidelines. The databases searched were MEDLINE (Ovid), Cochrane Central Register of Controlled Trials, and EMBASE (Ovid). The study quality and risk of bias were assessed using the Newcastle-Ottawa Quality Assessment Scale, and relevant data were extracted and synthesised. RESULTS Nine articles met the inclusion criteria. A total of 819 patients were included in this study. Eight of the nine studies were case series, and one was a randomised control trial. The mean risk of bias was 7.4/9 for non-randomised articles. The fixation methods used in the included studies were dynamic hip screw (DHS), cannulated screws, Smith-Peterson nail, hooknail, Moore's pins, and Knowle's pins. DHS was found to be a superior method of fixation and was supported by a clinical trial. It has high rates of union (99 %), low rates of avascular necrosis (<1 %), and low rates of fixation failure (<1 %). CONCLUSIONS Based on the available data, DHS appears to be the superior method of fixation for the minimally displaced subcapital neck of femoral fractures. Given the general low level of evidence currently available, additional clinical trials are needed in this area.
Collapse
Affiliation(s)
- Joash Kumar
- Department of Orthopaedics, Gold Coast Hospital and Health Service, Southport, Queensland, 4215, Australia
| | - Tristan Symonds
- Department of Orthopaedics, Ipswich Hospital and Health Service, Ipswich, Queensland, 4395, Australia
| | - Jonathan Quinn
- Department of Orthopaedics, Gold Coast Hospital and Health Service, Southport, Queensland, 4215, Australia
| | - Tom Walsh
- Office for Research Governance and Development, Gold Coast Hospital and Health Service, Southport, Queensland, 4215, Australia
- School of Clinical Sciences, Faculty of Health, Queensland University of Technology, Kelvin Grove, Queensland, 4059, Australia
| | - Simon Platt
- Department of Orthopaedics, Gold Coast Hospital and Health Service, Southport, Queensland, 4215, Australia
| |
Collapse
|
4
|
Ramadanov N, Jóźwiak K, Hauptmann M, Lazaru P, Marinova-Kichikova P, Dimitrov D, Becker R. Cannulated screws versus dynamic hip screw versus hemiarthroplasty versus total hip arthroplasty in patients with displaced and non-displaced femoral neck fractures: a systematic review and frequentist network meta-analysis of 5703 patients. J Orthop Surg Res 2023; 18:625. [PMID: 37626370 PMCID: PMC10464356 DOI: 10.1186/s13018-023-04114-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 08/19/2023] [Indexed: 08/27/2023] Open
Abstract
BACKGROUND Our aim was to determine the best operative procedure in human participants with a displaced or non-displaced femoral neck fracture comparing cannulated screw (CS) fixation, dynamic hip screw (DHS) fixation, hemiarthroplasty (HA), and total hip arthroplasty (THA) in terms of surgical and functional outcomes, reoperation and postoperative complications. METHODS We searched PubMed, The Cochrane Library, Clinical trials, CINAHL, and Embase for randomized controlled trials (RCTs) or quasi-RCTs up to 31 July 2022. A frequentist network meta-analysis was performed to assess the comparative effects of the four operative procedures, using fixed-effects and random-effects models. Mean differences (MDs) with 95% confidence intervals (CIs) were estimated for continuous variables and odds ratios (ORs) with 95% CIs were estimated for binary variables. RESULTS A total of 33 RCTs with 5703 patients were included in our network meta-analysis. CS fixation was best in terms of operation time (CS: MD = - 57.70, 95% CI - 72.78; - 42.62; DHS: MD = - 53.56, 95% CI - 76.17; - 30.95; HA: MD = - 20.90, 95% CI - 30.65; - 11.15; THA: MD = 1.00 reference) and intraoperative blood loss (CS: MD = - 3.67, 95% CI - 4.44; - 2.90; DHS: MD = - 3.20, 95% CI - 4.97; - 1.43; HA: MD = - 1.20, 95% CI - 1.73; - 0.67; THA: MD = 1.00 reference). In life quality and functional outcome, measured at different time points with EQ-5D and the Harris Hip Score (HHS), THA ranked first and HA second (e.g. EQ-5D 2 years postoperatively: CS: MD = - 0.20, 95% CI - 0.29; - 0.11; HA: MD = - 0.09, 95% CI - 0.17; - 0.02; THA: MD = 1.00 reference; HHS 2 years postoperatively: CS: MD = - 5.50, 95% CI - 9.98; - 1.03; DHS: MD = - 8.93, 95% CI - 15.08; - 2.78; HA: MD = - 3.65, 95% CI - 6.74; - 0.57; THA: MD = 1.00 reference). CS fixation had the highest reoperation risk, followed by DHS fixation, HA, and THA (CS: OR = 9.98, 95% CI 4.60; 21.63; DHS: OR = 5.07, 95% CI 2.15; 11.96; HA: OR = 1.60, 95% CI 0.89; 2.89; THA: OR = 1.00 reference). CONCLUSION In our cohort of patients with displaced and non-displaced femoral neck fractures, HHS, EQ-5D, and reoperation risk showed an advantage of THA and HA compared with CS and DHS fixation. Based on these findings, we recommend that hip arthroplasty should be preferred and internal fixation of femoral neck fractures should only be considered in individual cases. LEVEL OF EVIDENCE I a systematic review of randomized controlled trials. TRIAL REGISTRATION PROSPERO on 10 August 2022 (CRD42022350293).
Collapse
Affiliation(s)
- Nikolai Ramadanov
- Center of Orthopaedics and Traumatology, Brandenburg Medical School, University Hospital Brandenburg/Havel, Brandenburg an der Havel, Germany.
| | - Katarzyna Jóźwiak
- Institute of Biostatistics and Registry Research, Brandenburg Medical School Theodor Fontane, Neuruppin, Germany
| | - Michael Hauptmann
- Institute of Biostatistics and Registry Research, Brandenburg Medical School Theodor Fontane, Neuruppin, Germany
| | - Philip Lazaru
- General and Visceral Surgery, Minimally Invasive Surgery and Coloproctology, St. Marien Hospital, Berlin, Germany
| | - Polina Marinova-Kichikova
- Department of Surgical Propaedeutics, Faculty of Medicine, Medical University of Pleven, Pleven, Bulgaria
| | - Dobromir Dimitrov
- Department of Surgical Diseases, Faculty of Medicine, Medical University of Pleven, Pleven, Bulgaria
| | - Roland Becker
- Center of Orthopaedics and Traumatology, Brandenburg Medical School, University Hospital Brandenburg/Havel, Brandenburg an der Havel, Germany
| |
Collapse
|
5
|
Labmayr V, Borenich A, Pusch T, Reinbacher P, Hauer G, Sadoghi P, Leithner A, Berghold A, Puchwein P. Reoperation Rate of Internal Fixation for Femoral Neck Fractures in the Elderly - A Retrospective Follow-Up Study in 116 Patients With an Exploration of Risk Factors. Geriatr Orthop Surg Rehabil 2023; 14:21514593231164105. [PMID: 36923159 PMCID: PMC10009026 DOI: 10.1177/21514593231164105] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Revised: 02/18/2023] [Accepted: 02/21/2023] [Indexed: 03/14/2023] Open
Abstract
Aim Internal fixation of femoral neck fractures is a widely used procedure that is comparatively less invasive and faster than hip replacement. While head preserving internal fixation of these fractures are still preferred where feasible, a faster recovery and lower reoperation rates make arthroplasty increasingly more appealing, in spite of being a more invasive option. Our aim was to determine the reoperation rate after internal fixation at our institution and to explore relevant risk factors in a geriatric population. Methods This monocentric follow-up study was conducted analyzing 116 patients aged 65 and older with femoral neck fractures who were surgically treated with either cancellous screws or dynamic hip screws between 2010 and 2017. We retrospectively collected longitudinal data from our patient database, supplemented by a telephone survey, with a follow-up period of at least 18 months. Results Twenty reoperations, due to either a failure of fixation, avascular necrosis, or posttraumatic osteoarthritis, were identified in our cohort, which constituted a reoperation rate of 17.2% (20/116). Fracture displacement was significantly associated with the reoperation risk (HR 8, CI 3-20; P < .001). The reoperation rate was 52.2% in displaced fractures vs 8.9% in undisplaced fractures. No link was found between the reoperation rate and gender, age, BMI, ASA score, type of implant, quality of internal fixation, type of living accommodation, and pre-fracture mobility. Conclusion Internal fixation has been found to be an effective option in elderly patients with undisplaced fractures regardless of their specific age, cognitive ability or physical condition. In displaced fractures the reoperation rate was found to be high, therefore a primary hip replacement should be recommended.
Collapse
Affiliation(s)
- Viktor Labmayr
- Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
| | - Andrea Borenich
- Institute for Medical Informatics, Statistics and Documentation, Medical University Graz, Graz, Austria
| | - Thomas Pusch
- Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
| | - Patrick Reinbacher
- Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
| | - Georg Hauer
- Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
| | - Patrick Sadoghi
- Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
| | - Andreas Leithner
- Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
| | - Andrea Berghold
- Institute for Medical Informatics, Statistics and Documentation, Medical University Graz, Graz, Austria
| | - Paul Puchwein
- Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
| |
Collapse
|
6
|
Cullen SE, Sephton B, Malik I, Aldarragi A, Crossdale M, O’Connor M. A Comparative Study of Dynamic Hip Screw Versus Multiple Cannulated Compression Screw Fixation in Undisplaced Intracapsular Neck of Femur Fractures. Cureus 2022; 14:e31619. [DOI: 10.7759/cureus.31619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/16/2022] [Indexed: 11/19/2022] Open
|
7
|
van Leent EAP, Schmitz PP, de Jong LD, Zuurmond RG, Vos CJ, van Susante JLC, Somford MP. Complications and survival of conversion to total hip arthroplasty after failed primary osteosynthesis compared to primary total hip arthroplasty in femoral neck fractures. Injury 2022; 53:2853-2858. [PMID: 35236573 DOI: 10.1016/j.injury.2022.02.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Accepted: 02/05/2022] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Surgical treatment options for patients with an intracapsular fracture of the femoral neck (FFN) are primary osteosynthesis as a femoral head-spearing technique or primary (hemi)arthroplasty. The most common complications after primary osteosynthesis, such as avascular necrosis (AVN) or non-union, can result in conversion to Total Hip Arthroplasty (cTHA). Data concerning complications and survival rates of cTHA in comparison to primary Total Hip Arthroplasty (pTHA) after FFN are limited due to the absence of well-designed studies. METHODS A multicentre retrospective cohort study was conducted in three Dutch hospitals comparing the rate of postoperative dislocations, periprosthetic fractures, prosthetic joint infections, blood loss during surgery (>1000 mL), postoperative cardiac- and pulmonary complications after pTHA and cTHA in the first year after surgery. As a secondary outcome implant survival of pTHA and cTHA in terms of revision rates was evaluated. RESULTS In total 548 patients were included (pTHA n = 264 and cTHA n = 284) with a mean follow-up of 5 years (±3.5 SD). No significant differences were found in postoperative complications rates. The revision rate in the pTHA group was 7.2% in comparison to 7.7% in the cTHA group (p = 0.81). No difference in the short-term implant survival was found between both groups (p = 0.81). CONCLUSION This study showed no significant differences in terms of postoperative complication rates in the first year after pTHA and cTHA in patients with FFN. Also, no significant difference in short-term implant survival of primary and conversion total hip arthroplasty was found.
Collapse
Affiliation(s)
- E A P van Leent
- Department of Orthopaedics, Rijnstate Hospital, Wagnerlaan 55, 6815 AD, Arnhem, the Netherlands.
| | - P P Schmitz
- Department of Orthopaedics, Rijnstate Hospital, Wagnerlaan 55, 6815 AD, Arnhem, the Netherlands
| | - L D de Jong
- Department of Orthopaedics, Rijnstate Hospital, Wagnerlaan 55, 6815 AD, Arnhem, the Netherlands
| | - R G Zuurmond
- Department of Orthopaedics, Isala, Dr. van Heesweg 2, 8025 AB, Zwolle, the Netherlands
| | - C J Vos
- Department of Orthopaedics, Noordwest ziekenhuisgroep, Wilhelminalaan 12, 1815 JD, Alkmaar, the Netherlands
| | - J L C van Susante
- Department of Orthopaedics, Rijnstate Hospital, Wagnerlaan 55, 6815 AD, Arnhem, the Netherlands
| | - M P Somford
- Department of Orthopaedics, Rijnstate Hospital, Wagnerlaan 55, 6815 AD, Arnhem, the Netherlands
| |
Collapse
|
8
|
Cui L, Zhao S, Tian H, Guo W, Dong X. Curative efficacy of surgical procedures for older patients with femoral neck fracture: a network meta-analysis and systematic review. J Orthop Surg Res 2022; 17:127. [PMID: 35236384 PMCID: PMC8889721 DOI: 10.1186/s13018-022-02914-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Accepted: 01/03/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Femoral neck fractures have a higher incidence in older people with poor prognosis, inducing serious social problems. Common treatment methods include total hip arthroplasty, bipolar hemiarthroplasty, double-screw fixation, multiple-screw fixation, and dynamic hip system. METHODS We searched through four electronic databases, including PubMed, Web of Science, Cochrane Library, and Embase databases, for articles regarding femoral neck fractures, bone screw, and hip prosthesis published up to February 11, 2020. All included articles were used for quality evaluation and data extraction. Extracted data were expressed as odds ratios or weighted mean differences, with 95% confidence intervals. We conducted a network meta-analysis for Harris hip score, complications, 1-year mortality rate, reoperation rate, intraoperative blood loss, and duration of operation using STATA version 16.0 software. RESULTS Twenty-two randomized controlled trials and nine cohort studies included in this study involved 3861 patients. Total hip arthroplasty significantly improved the postoperative function of patients with femoral neck fractures. The surface under the cumulative ranking curve value of the Harris hip score for more than 1 year after total hip arthroplasty was 98.2. CONCLUSIONS This meta-analysis indicated no significant difference in mortality among different treatment groups. Total hip arthroplasty can provide satisfactory outcomes in hip joint function, and double-screw fixation results in the lowest intraoperative risk. In general, total hip arthroplasty results in a lower incidence of adverse events and is especially recommended for patients with femoral neck fractures. This article has been retrospectively registered on the International Platform of Registered Systematic Review and Meta-analysis Protocols (INPLASY) on November 27, 2020. Registration number: INPLASY2020110123.
Collapse
Affiliation(s)
- Lanxin Cui
- College of Mathematics, Jilin University, Changchun, Jilin Province, People's Republic of China
| | - Shishun Zhao
- College of Mathematics, Jilin University, Changchun, Jilin Province, People's Republic of China
| | - Heng Tian
- Department of Hand Surgery, The Second Hospital of Jilin University, Changchun, Jilin Province, People's Republic of China
| | - Wenlai Guo
- Department of Hand Surgery, The Second Hospital of Jilin University, Changchun, Jilin Province, People's Republic of China
| | - Xiaoming Dong
- Orthopaedic Medical Center, The Second Hospital of Jilin University, 218 Ziqiang Street, Changchun, 130041, Jilin Province, People's Republic of China.
| |
Collapse
|
9
|
Zhou Y, Zhang Y, Lu P, Chen H, Ni M, Rui Y. An overview on the treatment strategies of non-displaced femoral neck fracture in the elderly. ARTHROPLASTY 2022. [PMCID: PMC8887091 DOI: 10.1186/s42836-022-00111-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Background This paper aimed to review the databases on non-displaced femoral neck fractures in elderly patients. We also discussed the surgical and non-surgical treatments and selection of implants. Methods Reviewed was the literature on non-displaced femoral neck fractures in elderly patients. Four major medical databases and a combination of the search terms of “femoral neck fractures”, “nondisplaced”, “undisplaced”, “non-displaced”, “un-displaced”, “aged”, “the elderly”, and “geriatric” were used to search the literature relevant to the topic of the review. Results Patients who were unable to tolerate the operation and anesthesia could be treated conservatively. Otherwise, surgical treatment was a better choice. Specific surgical strategies and implant selection were important for the patient’s functional recovery. Conclusions The non-displaced femoral neck fractures are relatively stable but carry a risk of secondary displacement. Surgical treatments may be a better option because the implants provide additional stability and allow early exercise and ambulation. Hemiarthroplasty is also an alternative for old patients with higher risks of displacement and avascular necrosis of the femoral head.
Collapse
|
10
|
Zelle BA, Salazar LM, Howard SL, Parikh K, Pape HC. Surgical treatment options for femoral neck fractures in the elderly. INTERNATIONAL ORTHOPAEDICS 2022; 46:1111-1122. [DOI: 10.1007/s00264-022-05314-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Accepted: 01/17/2022] [Indexed: 12/16/2022]
|
11
|
Lewis SR, Macey R, Stokes J, Cook JA, Eardley WG, Griffin XL. Surgical interventions for treating intracapsular hip fractures in older adults: a network meta-analysis. Cochrane Database Syst Rev 2022; 2:CD013404. [PMID: 35156192 PMCID: PMC8841980 DOI: 10.1002/14651858.cd013404.pub2] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
BACKGROUND Hip fractures are a major healthcare problem, presenting a considerable challenge and burden to individuals and healthcare systems. The number of hip fractures globally is rising rapidly. The majority of intracapsular hip fractures are treated surgically. OBJECTIVES To assess the relative effects (benefits and harms) of all surgical treatments used in the management of intracapsular hip fractures in older adults, using a network meta-analysis of randomised trials, and to generate a hierarchy of interventions according to their outcomes. SEARCH METHODS We searched CENTRAL, MEDLINE, Embase, Web of Science, and five other databases in July 2020. We also searched clinical trials databases, conference proceedings, reference lists of retrieved articles and conducted backward-citation searches. SELECTION CRITERIA We included randomised controlled trials (RCTs) and quasi-RCTs comparing different treatments for fragility intracapsular hip fractures in older adults. We included total hip arthroplasties (THAs), hemiarthroplasties (HAs), internal fixation, and non-operative treatments. We excluded studies of people with hip fracture with specific pathologies other than osteoporosis or resulting from high-energy trauma. DATA COLLECTION AND ANALYSIS Two review authors independently assessed studies for inclusion. One review author completed data extraction which was checked by a second review author. We collected data for three outcomes at different time points: mortality and health-related quality of life (HRQoL) - both reported within 4 months, at 12 months, and after 24 months of surgery, and unplanned return to theatre (at end of study follow-up). We performed a network meta-analysis (NMA) with Stata software, using frequentist methods, and calculated the differences between treatments using risk ratios (RRs) and standardised mean differences (SMDs) and their corresponding 95% confidence intervals (CIs). We also performed direct comparisons using the same codes. MAIN RESULTS We included 119 studies (102 RCTS, 17 quasi-RCTs) with 17,653 participants with 17,669 intracapsular fractures in the review; 83% of fractures were displaced. The mean participant age ranged from 60 to 87 years and 73% were women. After discussion with clinical experts, we selected 12 nodes that represented the best balance between clinical plausibility and efficiency of the networks: cemented modern unipolar HA, dynamic fixed angle plate, uncemented first-generation bipolar HA, uncemented modern bipolar HA, cemented modern bipolar HA, uncemented first-generation unipolar HA, uncemented modern unipolar HA, THA with single articulation, dual-mobility THA, pins, screws, and non-operative treatment. Seventy-five studies (with 11,855 participants) with data for at least two of these treatments contributed to the NMA. We selected cemented modern unipolar HA as a reference treatment against which other treatments were compared. This was a common treatment in the networks, providing a clinically appropriate comparison. In order to provide a concise summary of the results, we report only network estimates when there was evidence of difference between treatments. We downgraded the certainty of the evidence for serious and very serious risks of bias and when estimates included possible transitivity, particularly for internal fixation which included more undisplaced fractures. We also downgraded for incoherence, or inconsistency in indirect estimates, although this affected few estimates. Most estimates included the possibility of benefits and harms, and we downgraded the evidence for these treatments for imprecision. We found that cemented modern unipolar HA, dynamic fixed angle plate and pins seemed to have the greatest likelihood of reducing mortality at 12 months. Overall, 23.5% of participants who received the reference treatment died within 12 months of surgery. Uncemented modern bipolar HA had higher mortality than the reference treatment (RR 1.37, 95% CI 1.02 to 1.85; derived only from indirect evidence; low-certainty evidence), and THA with single articulation also had higher mortality (network estimate RR 1.62, 95% CI 1.13 to 2.32; derived from direct evidence from 2 studies with 225 participants, and indirect evidence; very low-certainty evidence). In the remaining treatments, the certainty of the evidence ranged from low to very low, and we noted no evidence of any differences in mortality at 12 months. We found that THA (single articulation), cemented modern bipolar HA and uncemented modern bipolar HA seemed to have the greatest likelihood of improving HRQoL at 12 months. This network was comparatively sparse compared to other outcomes and the certainty of the evidence of differences between treatments was very low. We noted no evidence of any differences in HRQoL at 12 months, although estimates were imprecise. We found that arthroplasty treatments seemed to have a greater likelihood of reducing unplanned return to theatre than internal fixation and non-operative treatment. We estimated that 4.3% of participants who received the reference treatment returned to theatre during the study follow-up. Compared to this treatment, we found low-certainty evidence that more participants returned to theatre if they were treated with a dynamic fixed angle plate (network estimate RR 4.63, 95% CI 2.94 to 7.30; from direct evidence from 1 study with 190 participants, and indirect evidence). We found very low-certainty evidence that more participants returned to theatre when treated with pins (RR 4.16, 95% CI 2.53 to 6.84; only from indirect evidence), screws (network estimate RR 5.04, 95% CI 3.25 to 7.82; from direct evidence from 2 studies with 278 participants, and indirect evidence), and non-operative treatment (RR 5.41, 95% CI 1.80 to 16.26; only from indirect evidence). There was very low-certainty evidence of a tendency for an increased risk of unplanned return to theatre for all of the arthroplasty treatments, and in particular for THA, compared with cemented modern unipolar HA, with little evidence to suggest the size of this difference varied strongly between the arthroplasty treatments. AUTHORS' CONCLUSIONS There was considerable variability in the ranking of each treatment such that there was no one outstanding, or subset of outstanding, superior treatments. However, cemented modern arthroplasties tended to more often yield better outcomes than alternative treatments and may be a more successful approach than internal fixation. There is no evidence of a difference between THA (single articulation) and cemented modern unipolar HA in the outcomes measured in this review. THA may be an appropriate treatment for a subset of people with intracapsular fracture but we have not explored this further.
Collapse
Affiliation(s)
- Sharon R Lewis
- Bone and Joint Health, Blizard Institute, Queen Mary University of London, London, UK
| | - Richard Macey
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Oxford, UK
| | - Jamie Stokes
- Oxford Clinical Trials Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Oxford, UK
| | - Jonathan A Cook
- Oxford Clinical Trials Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Oxford, UK
| | - William Gp Eardley
- Department of Trauma and Orthopaedics, The James Cook University Hospital, Middlesbrough, UK
| | - Xavier L Griffin
- Bone and Joint Health, Blizard Institute, Queen Mary University of London, London, UK
- Barts Health NHS Trust, London, UK
| |
Collapse
|
12
|
Treatment of Valgus-Impacted and Nondisplaced Femoral Neck Fragility Fractures in the Elderly. J Am Acad Orthop Surg 2021; 29:470-477. [PMID: 33720080 DOI: 10.5435/jaaos-d-19-00866] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Accepted: 02/08/2021] [Indexed: 02/01/2023] Open
Abstract
As the life expectancy of the worldwide population increases, the number of hip fractures in the elderly cohort is expected to grow. It is important for surgeons to critically analyze available treatment options for these injuries, with the goal of optimizing outcomes and minimizing complications. Femoral neck fractures make up approximately half of all hip fractures. Nonoperative treatment of valgus-impacted and nondisplaced (Garden I and II) femoral neck fractures has high rates of secondary displacement, osteonecrosis, and nonunion; only patients with notable risk for perioperative complications are treated nonoperatively. Surgical intervention is the standard of care, with options including internal fixation (IF) with multiple cancellous screws or a sliding hip screw, hemiarthroplasty, or total hip arthroplasty. Patients with a posterior tilt of greater than 20° have a high rate of revision surgery when treated with IF and may benefit from primary arthroplasty. Furthermore, primary arthroplasty has demonstrated lower revision surgery rates and equivalent postoperative mortality when compared with IF. Surgeons should be aware of the functional outcomes, complications, revision surgery rates, and mortality rates associated with each treatment modality to make a patient-specific decision regarding their care.
Collapse
|
13
|
Liu K, Nagamune K, Oe K, Kuroda R, Niikura T. Migration Measurement of Pins in Postoperative Recovery of the Proximal Femur Fractures Based on 3D Point Cloud Matching. MEDICINA (KAUNAS, LITHUANIA) 2021; 57:406. [PMID: 33922398 PMCID: PMC8145055 DOI: 10.3390/medicina57050406] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2021] [Revised: 04/12/2021] [Accepted: 04/19/2021] [Indexed: 11/16/2022]
Abstract
Background and objectives: Internal fixation is one of the most effective methods for the treatment of proximal femur fractures. The migration of implants after the operation can seriously affect the reduction of treatment and even cause complications. Traditional diagnosis methods can not directly measure the extent of displacement. Methods: Based on the analysis of Hansson pins, this paper proposes a measurement method based on three-dimensional matching, which uses computerized tomography (CT) images of different periods of patients after the operation to analyze the implants' migration in three-dimensional space with the characteristics of fast speed and intuitive results. Results and conclusions: The measurement results show that the method proposed in this paper has more minor errors, more flexible coordinate system conversion, and more explicit displacement analysis than the traditional method of manually finding references in CT images and measuring displacement.
Collapse
Affiliation(s)
- Kaifeng Liu
- Department of Human and Artificial Intelligent Systems, Graduate School of Engineering, University of Fukui, Fukui 910-8507, Japan
| | - Kouki Nagamune
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe 650-0017, Japan; (K.N.); (K.O.); (R.K.); (T.N.)
| | - Keisuke Oe
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe 650-0017, Japan; (K.N.); (K.O.); (R.K.); (T.N.)
| | - Ryosuke Kuroda
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe 650-0017, Japan; (K.N.); (K.O.); (R.K.); (T.N.)
| | - Takahiro Niikura
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe 650-0017, Japan; (K.N.); (K.O.); (R.K.); (T.N.)
| |
Collapse
|
14
|
Lewis SR, Macey R, Eardley WG, Dixon JR, Cook J, Griffin XL. Internal fixation implants for intracapsular hip fractures in older adults. Cochrane Database Syst Rev 2021; 3:CD013409. [PMID: 33687067 PMCID: PMC8092427 DOI: 10.1002/14651858.cd013409.pub2] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
BACKGROUND Hip fractures are a major healthcare problem, presenting a huge challenge and burden to patients, healthcare systems and society. The increased proportion of older adults in the world population means that the absolute number of hip fractures is rising rapidly across the globe. The majority of hip fractures are treated surgically. This review evaluates evidence for types of internal fixation implants used in joint-preserving surgery for intracapsular hip fractures. OBJECTIVES To determine the relative effects (benefits and harms) of different implants for the internal fixation of intracapsular hip fractures in older adults. SEARCH METHODS We searched CENTRAL, MEDLINE, Embase, Web of Science, Cochrane Database of Systematic Reviews, Epistemonikos, Proquest Dissertations and Theses, and National Technical Information Service in July 2020. We also searched clinical trials databases, conference proceedings, reference lists of retrieved articles and conducted backward-citation searches. SELECTION CRITERIA We included randomised controlled trials (RCTs) and quasi-RCTs comparing implants used for internal fixation of fragility intracapsular proximal femoral fractures in older adults. Types of implants were smooth pins (these include pins with fold-out hooks), screws, or fixed angle plates. We excluded studies in which all or most fractures were caused by specific pathologies other than osteoporosis or were the result of a high energy trauma. DATA COLLECTION AND ANALYSIS Two review authors independently assessed studies for inclusion. One review author extracted data and assessed risk of bias which was checked by a second review author. We collected data for seven outcomes: activities of daily living (ADL), delirium, functional status, health-related quality of life (HRQoL), mobility, mortality (reported within four months of surgery as early mortality, and at 12 months since surgery), and unplanned return to theatre for treating a complication resulting directly or indirectly from the primary procedure (such as deep infection or non-union). We assessed the certainty of the evidence for these outcomes using GRADE. MAIN RESULTS We included 38 studies (32 RCTs, six quasi-RCTs) with 8585 participants with 8590 intracapsular fractures. The mean ages of participants in the studies ranged from 60 to 84 years; 73% were women, and 38% of fractures were undisplaced. We report here the findings of the four main comparisons, which were between different categories of implants. We downgraded the certainty of the outcomes for imprecision (when data were available from insufficient numbers of participants or the confidence interval (CI) was wide), study limitations (e.g. high or unclear risks of bias), and inconsistency (when we noted substantial levels of statistical heterogeneity). Smooth pins versus fixed angle plate (four studies, 1313 participants) We found very low-certainty evidence of little or no difference between the two implant types in independent mobility with no more than one walking stick (1 study, 112 participants), early mortality (1 study, 383 participants), mortality at 12 months (2 studies, 661 participants), and unplanned return to theatre (3 studies, 736 participants). No studies reported on ADL, delirium, functional status, or HRQoL. Screws versus fixed angle plates (11 studies, 2471 participants) We found low-certainty evidence of no clinically important differences between the two implant types in functional status using WOMAC (MD -3.18, 95% CI -6.35 to -0.01; 2 studies, 498 participants; range of scores from 0 to 96, lower values indicate better function), and HRQoL using EQ-5D (MD 0.03, 95% CI 0.00 to 0.06; 2 studies, 521 participants; range -0.654 (worst), 0 (dead), 1 (best)). We also found low-certainty evidence showing little or no difference between the two implant types in mortality at 12 months (RR 1.04, 95% CI 0.83 to 1.31; 7 studies, 1690 participants), and unplanned return to theatre (RR 1.10, 95% CI 0.95 to 1.26; 11 studies, 2321 participants). We found very low-certainty evidence of little or no difference between the two implant types in independent mobility (1 study, 70 participants), and early mortality (3 studies, 467 participants). No studies reported on ADL or delirium. Screws versus smooth pins (seven studies, 1119 participants) We found low-certainty evidence of no or little difference between the two implant types in mortality at 12 months (RR 1.07, 95% CI 0.85 to 1.35; 6 studies, 1005 participants; low-certainty evidence). We found very low-certainty evidence of little or no difference between the two implant types in early mortality (3 studies, 584 participants) and unplanned return to theatre (5 studies, 862 participants). No studies reported on ADL, delirium, functional status, HRQoL, or mobility. Screws or smooth pins versus fixed angle plates (15 studies, 3784 participants) In this comparison, we combined data from the first two comparison groups. We found low-certainty evidence of no or little difference between the two groups of implants in mortality at 12 months (RR 1.04, 95% CI.083 to 1.31; 7 studies, 1690 participants) and unplanned return to theatre (RR 1.02, 95% CI 0.88 to 1.18; 14 studies, 3057 participants). We found very low-certainty evidence of little or no difference between the two groups of implants in independent mobility (2 studies, 182 participants), and early mortality (4 studies, 850 participants). We found no additional evidence to support the findings for functional status or HRQoL as reported in 'Screws versus fixed angle plates'. No studies reported ADL or delirium. AUTHORS' CONCLUSIONS There is low-certainty evidence that there may be little or no difference between screws and fixed angle plates in functional status, HRQoL, mortality at 12 months, or unplanned return to theatre; and between screws and pins in mortality at 12 months. The limited and very low-certainty evidence for the outcomes for which data were available for the smooth pins versus fixed angle plates comparison, as well as the other outcomes for which data were available for the screws and fixed angle plates, and screws and pins comparisons means we have very little confidence in the estimates of effect for these outcomes. Additional RCTs would increase the certainty of the evidence. We encourage such studies to report outcomes consistent with the core outcome set for hip fracture, including long-term quality of life indicators such as ADL and mobility.
Collapse
Affiliation(s)
- Sharon R Lewis
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Oxford, UK
| | - Richard Macey
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Oxford, UK
| | - Will Gp Eardley
- Department of Trauma and Orthopaedics, The James Cook University Hospital, Middlesbrough, UK
| | | | - Jonathan Cook
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Oxford, UK
| | | |
Collapse
|
15
|
Current Trends in the Evaluation and Management of Nondisplaced Femoral Neck Fractures in the Elderly. J Am Acad Orthop Surg 2021; 29:e154-e164. [PMID: 33201046 DOI: 10.5435/jaaos-d-20-00349] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 09/14/2020] [Indexed: 02/01/2023] Open
Abstract
Nondisplaced (Garden I and II) femoral neck (FN) fractures are commonly encountered by the practicing orthopaedic surgeon. Although these fractures are primarily classified based on the AP radiograph, the lateral radiograph should be closely scrutinized as well because posterior tilt has emerged as a consistent predictor of fixation failure. Internal fixation has for many years been the standard of care, with both cannulated screws and the sliding hip screw representing acceptable options. However, the outcomes after fixation of Garden I and II FN fractures have not been uniformly positive, with the rates of revision surgery ranging from 8% to 27%. Complications after fixation of nondisplaced FN fractures include nonunion, fixation failure, osteonecrosis, and femoral shortening causing inferior hip function. For these reasons, arthroplasty is increasingly considered a viable option in the treatment of these fractures, especially in the presence of factors that predispose to failure after fixation. Novel devices for FN fixation have recently been developed, although clinical data supporting their use are sparse at the present time.
Collapse
|
16
|
Xia Y, Zhang W, Zhang Z, Wang J, Yan L. Treatment of femoral neck fractures: sliding hip screw or cannulated screws? A meta-analysis. J Orthop Surg Res 2021; 16:54. [PMID: 33446230 PMCID: PMC7807723 DOI: 10.1186/s13018-020-02189-1] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Accepted: 12/27/2020] [Indexed: 12/21/2022] Open
Abstract
Purpose Femoral neck fractures are still unsolved problems nowadays; sliding hip screw (SHS) and cannulated compression screw (CCS) are the most commonly used devices. We evaluated the clinical outcomes and complications in the treatment of femoral neck fractures between SHS and CCS in this meta-analysis to find which is better. Methods We searched PubMed, Embase, Cochrane library up to 24 August 2020 and retrieved any studies comparing sliding hip screw and cannulated compression screw in treatment of femoral neck fractures; the main outcomes and complications were extracted from the studies which were included. Results Nine studies involving 1662 patients (828 patients in the SHS group and 834 patients in the CCS group) were included in this study. SHS had higher rate of avascular necrosis (RR = 1.30, 95% CI 1.08–1.56, p = 0.005), and CCS had higher rate of implant removal (RR = 0.63, 95% CI 0.43–0.93, p = 0.02). No significant statistical difference in non-union, implant failure, infection, replacement, mortality, orthopedic complications, non-orthopedic complications, and total revision between SHS and CCS group. Conclusion Both devices have their pros and cons; SHS had a higher rate of avascular necrosis, and CCS had a higher rate of implant removal rate. No significant statistical difference in non-union, implant failure, infection, replacement, mortality, orthopedic complications, non-orthopedic complications, and total revision between SHS and CCS group.
Collapse
Affiliation(s)
- Yutong Xia
- Dalian Medical University, Dalian, 116044, Liaoning Province, China
| | - Wendong Zhang
- Department of Orthopedics, Northern Jiangsu People's Hospital, Yangzhou, 225001, China
| | - Zhen Zhang
- Dalian Medical University, Dalian, 116044, Liaoning Province, China
| | - Jingcheng Wang
- Dalian Medical University, Dalian, 116044, Liaoning Province, China. .,Department of Orthopedics, Northern Jiangsu People's Hospital, Yangzhou, 225001, China.
| | - Lianqi Yan
- Department of Orthopedics, Northern Jiangsu People's Hospital, Yangzhou, 225001, China. .,The second Xiangya hospital of Central South University, Changsha, Hunan, 410012, China.
| |
Collapse
|
17
|
Anderson JT, Hudyk AR, Haas AR, Ahn NU, Rothberg DL, Gililland JM. Displaced Femoral Neck Fractures in Workers' Compensation Patients Aged 45-65 Years: Is It Best to Fix the Fracture or Replace the Joint? J Arthroplasty 2020; 35:3195-3203. [PMID: 32600808 DOI: 10.1016/j.arth.2020.06.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 05/29/2020] [Accepted: 06/02/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Optimal surgical management of displaced femoral neck fractures (dFNFs) in subjects 45-65 years old is unclear. We evaluated days out of work (dOOW), medical and indemnity costs, and secondary outcomes at 2 years between internal fixation (IF), hemiarthroplasty (HA), and total hip arthroplasty (THA) among workers' compensation (WC) subjects with isolated dFNFs aged 45-65. METHODS We retrospectively identified 105 Ohio Bureau of WC subjects with isolated subcapital dFNFs aged 45-65 with 2 years of follow-up. In total, 37 (35.2%) underwent IF, 23 (21.9%) THA, and 45 (42.9%) HA from 1993 to 2017. Linear regression was used to determine if surgery type was predictive of dOOW postoperatively and to evaluate inflation-adjusted net medical and indemnity costs at 2 years. RESULTS IF subjects were younger (52.9) than THA (58.5, P < .001) and HA (58.4, P < .001) subjects. Mean dOOW for THA subjects at 6 months, 1 year, and 2 years was 90.8, 114.6, and 136.6. This was significantly lower than IF (136.3, 182.0, 236.6) and HA (114.6, 153.3, 247.6) subjects at all time points. Medical costs were similar. Mean indemnity costs were 3.0 and 2.4 times higher among IF (P < .001) and HA (P = .007) groups compared to THA, respectively. Rates of postoperative permanent disability awards were 13.0%, 43.2%, and 35.6% for the THA, IF, and HA groups (P = .050). IF and HA subjects had a 24.3% and 11.1% revision rate. Overall, 77.8% and 100% of the IF and HA revisions were conversions to THA. CONCLUSION WC subjects aged 45-65 with dFNFs treated with THA had fewer dOOW, lower indemnity costs, and less disability at 2 years. Longer follow-up will help determine the durability and long-term outcomes of these surgeries.
Collapse
Affiliation(s)
- Joshua T Anderson
- Department of Orthopaedic Surgery, University of Utah, Salt Lake City, UT
| | | | | | - Nicholas U Ahn
- Department of Orthopaedics, University Hospitals Cleveland Medical Center, Cleveland, OH
| | - David L Rothberg
- Department of Orthopaedic Surgery, University of Utah, Salt Lake City, UT
| | - Jeremy M Gililland
- Department of Orthopaedic Surgery, University of Utah, Salt Lake City, UT
| |
Collapse
|
18
|
Li L, Zhao X, Yang X, Tang X, Liu M. Dynamic hip screws versus cannulated screws for femoral neck fractures: a systematic review and meta-analysis. J Orthop Surg Res 2020; 15:352. [PMID: 32843048 PMCID: PMC7449015 DOI: 10.1186/s13018-020-01842-z] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Accepted: 07/30/2020] [Indexed: 02/07/2023] Open
Abstract
OBJECTIVE Dynamic hip screw (DHS) and cannulated screws (CS) are widely used for femoral neck fractures. However, there is no definite result as to which surgical method bring less complications. We performed this study to compare the complication (mortality, non-union, avascular necrosis (AVN), and revision) of DHS and CS for the treatment of femoral neck fractures patients. METHODS We searched Pubmed, Ovid, Cochrane Central Register of Controlled Trials, and other relevant studies related the comparison of DHS versus CS for femoral neck fractures from inception to Jan 7, 2020. The quality of the included randomized controlled trials (RCTs) and retrospective studies were assessed using the Cochrane Collaboration tool and Newcastle-Ottawa (NOS), respectively. The meta-analysis was performed by the RevMan 5.2 software. RESULTS Nine RCTs and seven retrospective cohort studies were included for meta-analysis. CS was found to be superior to DHS with respect to AVN rate (OR 1.47; 95% CI 1.08-1.99; p = 0.01, I2 = 0%). There were no significant between-group differences with respect to mortality, non-union, and revision (p > 0.05). CONCLUSION DHS and CS have similar complication including mortality, revision rate, and non-union, but CS has superior to DHS on ANV. However, further studies are required to provide more robust evidence owing to some limitations.
Collapse
Affiliation(s)
- Lang Li
- Department of Pediatric Surgery, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, People's Republic of China
| | - Xue Zhao
- Department of Obstetrics and Gynaecology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, People's Republic of China
| | - Xiaodong Yang
- Department of Pediatric Surgery, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, People's Republic of China
| | - Xueyang Tang
- Department of Pediatric Surgery, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, People's Republic of China
| | - Ming Liu
- Department of Orthopedics, West China Hospital, Sichuan University, #37, Guo Xue Xiang, Chengdu, 610041, Sichuan, People's Republic of China.
| |
Collapse
|
19
|
Shin KH, Hong SH, Han SB. Posterior fully threaded positioning screw prevents femoral neck collapse in Garden I or II femoral neck fractures. Injury 2020; 51:1031-1037. [PMID: 32089281 DOI: 10.1016/j.injury.2020.01.032] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2019] [Accepted: 01/23/2020] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Osteosynthesis is recommended for Garden I and II femoral neck fracture treatment using parallel partially threaded cannulated screws. Postoperatively, excessive femoral neck shortening (FNS) and posterior tilt of the femoral neck (PTFN) are frequently encountered and are correlated with impaired quality of life and clinical outcomes. We hypothesized that stabilization by parallel partially threaded cannulated screws replacing a posterior partially threaded screw with a fully threaded positioning screw would improve fracture healing without further FNS and PTFN in femoral neck fractures. METHODS We retrospectively reviewed Garden I and II femoral neck fractures treated by in situ fixation using parallel cannulated screws at our institution between January 2010 and November 2018. Patients with the applicable fractures were divided according to the utilization of posterior fully threaded screws: patients with partially threaded screws were included in Group C and those with posterior fully threaded screws were included in Group P. Intergroup comparisons were performed based on radiographic measurements that assessed the shortening in two vectors (the horizontal and vertical axes), FNS, and subsequent PTFN. RESULTS No significant intergroup difference was found in demographics and fracture characteristics, except in the follow-up duration. The mean FNS and shortening in both vectors were significantly smaller in Group P than in Group C (FNS, 5.02 ± 1.31 vs. 8.84 ± 3.48 mm, p < 0.001; horizontal axis, 4.07 ± 1.06 vs. 6.18 ± 2.77 mm, p < 0.001; and vertical axis, 2.55 ± 1.68 vs. 5.74 ± 3.41 mm, p < 0.001). The mean subsequent PTFN was significantly smaller in Group P (2.21 ± 2.99 vs. 7.56 ± 6.20 mm, p < 0.001). A significantly smaller number of patients in Group P had moderate (5-10 mm) or severe (>10 mm) FNS and moderate (5-10°) or severe (>10°) subsequent PTFN. CONCLUSION Parallel cannulated screws replacing a posterior partially threaded screw with a fully threaded positioning screw as a length- and angle-stable construct for Garden I or II femoral neck fracture fixation can prevent femoral neck collapse in both the coronal and axial planes.
Collapse
Affiliation(s)
- Kyun-Ho Shin
- Department of Orthopaedic Surgery, Anam Hospital, Korea University College of Medicine, Seoul, South Korea
| | - Seok-Ha Hong
- Department of Orthopaedic Surgery, Anam Hospital, Korea University College of Medicine, Seoul, South Korea
| | - Seung-Beom Han
- Department of Orthopaedic Surgery, Anam Hospital, Korea University College of Medicine, Seoul, South Korea.
| |
Collapse
|
20
|
Cordeiro M, Caskey S, Frank C, Martin S, Srivastava A, Atkinson T. Hybrid triad provides fracture plane stability in a computational model of a Pauwels Type III hip fracture. Comput Methods Biomech Biomed Engin 2020; 23:476-483. [PMID: 32160804 DOI: 10.1080/10255842.2020.1738404] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
The study utilized finite element method to determine displacements and stresses in a set of Pauwels Type III femoral neck fractures repaired using 3 techniques (cannulated screws (Triad), sliding hip screw (SHS), and a Hybrid (SHS + cannulated screws). The research found that shear displacement doubled between the 65° and 75° fracture angles regardless of fixation construct. The SHS alone was the least stable construct, with highest construct stresses and shear displacement along the fracture plane. The stability of the Hybrid and Triad constructs were similar, but stress in the Hybrid was lower suggesting it would provide a higher load to failure than the Triad.
Collapse
Affiliation(s)
- M Cordeiro
- Orthopaedic Surgery, McLaren-Flint, Flint, MI, USA
| | - S Caskey
- Orthopaedic Surgery, McLaren-Flint, Flint, MI, USA
| | - C Frank
- Orthopaedic Surgery, McLaren-Flint, Flint, MI, USA
| | - S Martin
- Orthopaedic Surgery, McLaren-Flint, Flint, MI, USA
| | - A Srivastava
- Orthopaedic Surgery, McLaren-Flint, Flint, MI, USA
| | - T Atkinson
- Orthopaedic Surgery, McLaren-Flint, Flint, MI, USA.,Department of Mechanical Engineering, Kettering University, Flint, MI, USA
| |
Collapse
|
21
|
Alizade C, Jafarov A, Alizada F, Gülsen M, Togrul E. Efficiency of an implant: new criterion of objective assessment of implants for osteosynthesis of femoral neck fracture. INTERNATIONAL ORTHOPAEDICS 2020; 44:569-575. [PMID: 31848657 DOI: 10.1007/s00264-019-04439-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2019] [Accepted: 10/18/2019] [Indexed: 12/11/2022]
Abstract
PURPOSE In line with several designs for osteosynthesis of femoral neck fracture (FNF), their effectiveness is still estimated by the results of biomechanical and clinical trials, finite element method (FE). But surgeons require the criteria which would define their properties in advance and allow improve the results of treatment. METHODS When new implant (NI) is being designed, we developed such criterion - index efficiency of an implant (IEI) - and performed mathematical comparative researches of properties of NI with the known designs. We analyzed the results of comparative clinical trials on treatment of FNF with various implants considering their IEI. RESULTS Analysis showed that results of comparative clinical trials with the use of various implants for osteosynthesis FNF completely correlated to their IEI; IEI of the NI two to three times exceeds IEI of all known designs, and the destruction percentage of a bone tissue is two to three times less when it is applied. CONCLUSION The offered IEI can be used for designing new implants and allows improving the results of treatment of patients with FNF by optimizing the choice of implant for osteosynthesis.
Collapse
Affiliation(s)
- Chingiz Alizade
- Department of Orthopaedics and Traumatology Surgery, Baku Health Center, Azadliq ave., 112, Baku, AZ1110, Republic of Azerbaijan.
| | - Afgan Jafarov
- Department of Orthopaedics and Traumatology Surgery, Modern Hospital, Baku, Republic of Azerbaijan
| | - Farhad Alizada
- Asklepios Kliniken Langen-Seligenstadt, Seligenstadt, Germany
| | | | | |
Collapse
|
22
|
Davey MS, Flynn SO, Hayes J, Feeley I, Grant Freemantle MC, Burke N. Two-hole versus four-hole plate dynamic hip screw: a systematic review of current evidence. Ir J Med Sci 2020; 189:1317-1322. [PMID: 32067189 DOI: 10.1007/s11845-020-02184-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Accepted: 01/23/2020] [Indexed: 11/28/2022]
Abstract
BACKGROUND The dynamic hip screw (DHS) is a common device used in the fixation of hip fractures. Traditionally, this involves the use of a four-hole side plate. Reducing the length of the side plate would theoretically reduce the amount of surgical exposure required, decrease surgery duration, and decrease perioperative morbidity and mortality. Our study aims to review the current evidence regarding the use of two-hole side plates, their use and potential complications. METHODS Using PRISMA guidelines, two independent reviewers performed a search to collate the available literature from medical databases PubMed, EMBASE, Web of Science, and the Cochrane library. Only clinical and biochemical studies were included. The reference lists of articles included for full text review were searched for any additional primary or review publications. RESULTS Four online libraries were searched, with a combined total of 5344 titles reviewed. Following title, abstract, and full text review, 8 articles were considered suitable for inclusion in qualitative analysis. There was a trend towards equal efficiency between two- and four-hole plates when used in stable fractures in terms of blood loss, failure/revision rates, operative and hospital stay durations, collapse loading testing, maximum stress, and fragment migration. CONCLUSION The results of this study show that DHS constructs with two- or four-hole side plates have comparable outcomes when used in patients with stable fracture patterns. However, the majority of the clinical data regarding the use of two-hole DHS plates come from retrospective case series; further prospective, randomised control trials would be of significant benefit. LEVEL OF EVIDENCE Level II; systematic review of all levels of evidence.
Collapse
Affiliation(s)
- Martin S Davey
- Department of Trauma & Orthopaedics, Beaumont Hospital, Dublin 9, Ireland. .,Royal College of Surgeons in Ireland, Dublin 2, Ireland.
| | - Sean O Flynn
- Department of Trauma & Orthopaedics, Beaumont Hospital, Dublin 9, Ireland.,Royal College of Surgeons in Ireland, Dublin 2, Ireland
| | - Joshua Hayes
- Department of Trauma & Orthopaedics, Beaumont Hospital, Dublin 9, Ireland.,Royal College of Surgeons in Ireland, Dublin 2, Ireland
| | - Iain Feeley
- Department of Trauma & Orthopaedics, Beaumont Hospital, Dublin 9, Ireland.,Royal College of Surgeons in Ireland, Dublin 2, Ireland
| | - Marc C Grant Freemantle
- Department of Trauma & Orthopaedics, Beaumont Hospital, Dublin 9, Ireland.,Royal College of Surgeons in Ireland, Dublin 2, Ireland
| | - Neil Burke
- Department of Trauma & Orthopaedics, Beaumont Hospital, Dublin 9, Ireland
| |
Collapse
|
23
|
Zhou Y, Ni Y, Li X, Chen H, Rui Y. [Research progress in treatment of femoral neck fracture in the elderly]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2019; 33:1033-1040. [PMID: 31407565 PMCID: PMC8337910 DOI: 10.7507/1002-1892.201901118] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 06/30/2019] [Indexed: 02/01/2023]
Abstract
OBJECTIVE To introduce the research progress of conservative treatment, internal fixation, hip arthroplasty, and multidisciplinary team (MDT) modes in the treatment of femoral neck fracture in the elderly. METHODS By consulting domestic and foreign literature in recent years, the characteristics and application of various treatment methods and new treatment modes for femoral neck fracture in the elderly were summarized and analyzed. RESULTS The elderly non-displaced femoral neck fracture should be treated surgically, and conservative treatment has a high risk of secondary displacement. The displaced fracture should be operated as soon as possible. There is no difference in long-term functional outcome between hemiarthroplasty and total hip arthroplasty. Hemiarthroplasty has less intraoperative blood loss, shorter operation time, and is suitable for the elderly patients with poor basic condition. Total hip arthroplasty is suitable for the elderly patients with better basic condition and higher demand of life quality. MDT can effectively reduce preoperative waiting time and length of stay, reduce the incidence of medical complications, improve the nutritional status of patients, and reduce the mortality of patients. CONCLUSION Significant results have been achieved in the treatment of femoral neck fractures in the elderly by methods such as internal fixation, hip arthroplasty, and MDT.
Collapse
Affiliation(s)
- Yangyang Zhou
- Department of Traumatic Orthopaedics, Zhongda Hospital, School of Medicine, Southeast University, Nanjing Jiangsu, 210009, P.R.China;Institute of Traumatic Orthopaedics, School of Medicine, Southeast University, Nanjing Jiangsu, 210009, P.R.China;Multidisciplinary Team (MDT) for Geriatric Hip Fracture Management, Zhongda Hospital, School of Medicine, Southeast University, Nanjing Jiangsu, 210009, P.R.China;Trauma Center, Zhongda Hospital, School of Medicine, Southeast University, Nanjing Jiangsu, 210009, P.R.China
| | - Yingjie Ni
- Department of Orthopaedics, Xishan People's Hospital of Wuxi, Wuxi Jiangsu, 214105, P.R.China;Department of Orthopaedics, Wuxi Branch of Zhongda Hospital, School of Medicine, Southeast University, Nanjing Jiangsu, 214105, P.R.China
| | - Xingjuan Li
- Department of Geriatrics, Zhongda Hospital, School of Medicine, Southeast University, Nanjing Jiangsu, 210009, P.R.China
| | - Hui Chen
- Department of Traumatic Orthopaedics, Zhongda Hospital, School of Medicine, Southeast University, Nanjing Jiangsu, 210009, P.R.China;Institute of Traumatic Orthopaedics, School of Medicine, Southeast University, Nanjing Jiangsu, 210009, P.R.China;Multidisciplinary Team (MDT) for Geriatric Hip Fracture Management, Zhongda Hospital, School of Medicine, Southeast University, Nanjing Jiangsu, 210009, P.R.China;Trauma Center, Zhongda Hospital, School of Medicine, Southeast University, Nanjing Jiangsu, 210009, P.R.China
| | - Yunfeng Rui
- Department of Traumatic Orthopaedics, Zhongda Hospital, School of Medicine, Southeast University, Nanjing Jiangsu, 210009, P.R.China;Institute of Traumatic Orthopaedics, School of Medicine, Southeast University, Nanjing Jiangsu, 210009, P.R.China;Multidisciplinary Team (MDT) for Geriatric Hip Fracture Management, Zhongda Hospital, School of Medicine, Southeast University, Nanjing Jiangsu, 210009, P.R.China;Trauma Center, Zhongda Hospital, School of Medicine, Southeast University, Nanjing Jiangsu, 210009, P.R.China;Department of Orthopaedics, Xishan People's Hospital of Wuxi, Wuxi Jiangsu, 214105, P.R.China;Department of Orthopaedics, Wuxi Branch of Zhongda Hospital, School of Medicine, Southeast University, Nanjing Jiangsu, 214105,
| |
Collapse
|
24
|
Shehata MSA, Aboelnas MM, Abdulkarim AN, Abdallah AR, Ahmed H, Holton J, Consigliere P, Narvani AA, Sallam AA, Wimhurst JA, Imam MA. Sliding hip screws versus cancellous screws for femoral neck fractures: a systematic review and meta-analysis. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2019; 29:1383-1393. [PMID: 31165917 DOI: 10.1007/s00590-019-02460-0] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2019] [Accepted: 05/29/2019] [Indexed: 01/24/2023]
Abstract
PURPOSE Both sliding hip screws (SHS) and cancellous screws are used in the surgical management of intracapsular femoral neck fracture. However, there is paucity of information as to which is the superior treatment modality. We performed this systematic review and meta-analysis study to compare the clinical outcomes of SHS and cancellous screws for the treatment of femoral neck fractures in adult patients. METHODS We searched PubMed, Scopus, Web of Science, and Cochrane CENTRAL, up to December 2017. Randomized controlled trials (RCTs) directly comparing the clinical outcomes of SHS and cancellous screws for femoral neck fractures were retrieved with no language or publication year restrictions. Data retrieved included operative details, nonunion rate, avascular necrosis, reoperation, infection and mortality, hip pain, functional hip scores, and medical complications. These were pooled as risk ratio or mean difference (MD) with their corresponding 95% confidence interval (CI). Heterogeneity was assessed by Chi-square test. RESULTS Ten RCTs involving 1934 patients were included in the final analysis. The pooled estimate showed that the SHS group was associated with more intraoperative blood loss (MD = 110.01 ml, 95% CI [52.42, 167.60], p = 0.00002) than the cancellous screws. There was no significant difference in terms of operative time, postoperative hip function, nonunion, avascular necrosis, reoperation rate, infection, fracture healing, hip pain, medical complications, and mortality rate. CONCLUSION Based on our study, the cancellous screws group was associated with less intraoperative blood loss in comparison with the SHS group. No other significant differences were found between the two interventions.
Collapse
Affiliation(s)
| | | | | | | | - Hussien Ahmed
- Faculty of Medicine, Zagazig University, Zagazig, Egypt
| | | | | | - Ali A Narvani
- Rowley Bristow Orthopaedic Center, St Peter's Hospital, Chertsey, UK
| | - Asser A Sallam
- Department of Orthopedic Surgery and Trauma, Suez Canal University Hospitals, Kilo 4.5 Ring Road, Ismailia, 41111, Egypt.
| | - James A Wimhurst
- Norfolk and Norwich University Hospital, University of East Anglia, Norwich, UK
| | - Mohamed A Imam
- Department of Orthopedic Surgery and Trauma, Suez Canal University Hospitals, Kilo 4.5 Ring Road, Ismailia, 41111, Egypt.,Norfolk and Norwich University Hospital, University of East Anglia, Norwich, UK
| |
Collapse
|
25
|
Threading the Needle: Intrapelvic Displacement of a Femoral Neck Fracture through the Obturator Foramen. Case Rep Orthop 2018; 2018:2506187. [PMID: 29808142 PMCID: PMC5902099 DOI: 10.1155/2018/2506187] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2018] [Accepted: 02/19/2018] [Indexed: 11/24/2022] Open
Abstract
Despite timely and appropriate management, displaced femoral neck fractures are often devastating injuries for the young patient. The risk of negative sequelae is further amplified with increasing displacement and vertical fracture patterns. Open anatomic reduction with rigid internal fixation is essential to maximize the healing potential in displaced fractures of the femoral neck. Successful primary osteosynthesis of significantly displaced femoral neck fractures in the young patient has been reported in the literature. We present a unique case of open reduction and internal fixation of a high-energy femoral neck fracture with extrusion of the head through the obturator foramen into the pelvis without associated acetabular or pelvic injury.
Collapse
|
26
|
Holloway KL, Sajjad MA, Mohebbi M, Kotowicz MA, Livingston PM, Khasraw M, Hakkennes S, Dunning TL, Brumby S, Page RS, Pedler D, Sutherland A, Venkatesh S, Brennan-Olsen SL, Williams LJ, Pasco JA. The epidemiology of hip fractures across western Victoria, Australia. Bone 2018; 108:1-9. [PMID: 29229437 DOI: 10.1016/j.bone.2017.12.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2017] [Revised: 12/01/2017] [Accepted: 12/07/2017] [Indexed: 11/17/2022]
Abstract
BACKGROUND Hip fractures are associated with considerable morbidity and mortality. Hip fracture incidence varies across different levels of accessibility/remoteness and socioeconomic status (SES). As part of the Ageing, Chronic Disease and Injury Study, we aimed to map the pattern of hip fractures across the western region of the Australian state of Victoria, which contains a range of remoteness levels and SES. METHODS Data on hip fractures resulting in hospital admission were extracted from the Victorian Admitted Episodes Dataset (VAED) for men and women aged 40+years during 2010-2013 inclusive. An age-adjusted incidence rate (per 10,000population/year) was calculated for the entire region. Crude incidence rates and length of acute care hospital stay (excluding rehabilitation) were calculated for each Local Government Area (LGA). The impact of aggregated age, accessibility/remoteness index of Australia (ARIA) and SES on hip fracture rates aggregated across LGAs was determined using Poisson regression. RESULTS For men, the age-standardised rate of hospitalisations for hip fracture across the whole region was 19.2 per 10,000population/year (95%CI 18.0-20.4) and for women, 40.0 (95%CI 38.3-41.7). The highest incidence rates for both sexes occurred in the less accessible LGAs of Yarriambiack and Hindmarsh, as well as the LGA with the lowest SES, Central Goldfields. In both sexes, approximately two thirds of individuals were discharged from acute hospital care within 14days. Increasing age, higher remoteness and lower SES were all associated with higher hip fracture rates. CONCLUSION Crude incidence rates varied by location. Given that a high proportion of patients had acute hospital care of ≤14days, and accessibility and SES were associated with hip fracture rates, these results can inform policy and provide a model for other groups to conduct similar research in their local environment.
Collapse
Affiliation(s)
| | | | | | - Mark A Kotowicz
- Deakin University, School of Medicine, Geelong, Australia; Department of Medicine-Western Health, Melbourne Medical School, The University of Melbourne, Victoria, Australia; University Hospital Geelong, Barwon Health, Geelong, Australia
| | | | | | | | | | - Susan Brumby
- Deakin University, School of Medicine, Geelong, Australia; National Centre for Farmer Health, Western District Health Service, Hamilton, Australia
| | - Richard S Page
- Deakin University, School of Medicine, Geelong, Australia; University Hospital Geelong, Barwon Health, Geelong, Australia; Barwon Centre of Orthopaedic Research and Education (B-CORE), St John of God Hospital and Barwon Health, Geelong, Australia
| | - Daryl Pedler
- Deakin University, School of Medicine, Geelong, Australia
| | - Alasdair Sutherland
- Deakin University, School of Medicine, Geelong, Australia; South West Healthcare, Warrnambool, Australia
| | | | - Sharon L Brennan-Olsen
- Deakin University, School of Medicine, Geelong, Australia; Department of Medicine-Western Health, Melbourne Medical School, The University of Melbourne, Victoria, Australia; Australian Institute for Musculoskeletal Science (AIMSS), The University of Melbourne, Australia; The Institute for Health and Ageing, Australian Catholic University, Melbourne, Australia
| | | | - Julie A Pasco
- Deakin University, School of Medicine, Geelong, Australia; Department of Medicine-Western Health, Melbourne Medical School, The University of Melbourne, Victoria, Australia; University Hospital Geelong, Barwon Health, Geelong, Australia
| |
Collapse
|
27
|
Multiple cannulated screws vs. dynamic hip screws for femoral neck fractures. DER ORTHOPADE 2017; 46:954-962. [DOI: 10.1007/s00132-017-3473-8] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
28
|
Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial. Lancet 2017; 389:1519-1527. [PMID: 28262269 PMCID: PMC5597430 DOI: 10.1016/s0140-6736(17)30066-1] [Citation(s) in RCA: 201] [Impact Index Per Article: 28.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2016] [Revised: 10/25/2016] [Accepted: 11/01/2016] [Indexed: 12/26/2022]
Abstract
BACKGROUND Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. METHODS For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. FINDINGS Between March 3, 2008, and March 31, 2014, we randomly assigned 1108 patients to receive a sliding hip screw (n=557) or cancellous screws (n=551). Reoperations within 24 months did not differ by type of surgical fixation in those included in the primary analysis: 107 (20%) of 542 patients in the sliding hip screw group versus 117 (22%) of 537 patients in the cancellous screws group (hazard ratio [HR] 0·83, 95% CI 0·63-1·09; p=0·18). Avascular necrosis was more common in the sliding hip screw group than in the cancellous screws group (50 patients [9%] vs 28 patients [5%]; HR 1·91, 1·06-3·44; p=0·0319). However, no significant difference was found between the number of medically related adverse events between groups (p=0·82; appendix); these events included pulmonary embolism (two patients [<1%] vs four [1%] patients; p=0·41) and sepsis (seven [1%] vs six [1%]; p=0·79). INTERPRETATION In terms of reoperation rates the sliding hip screw shows no advantage, but some groups of patients (smokers and those with displaced or base of neck fractures) might do better with a sliding hip screw than with cancellous screws. FUNDING National Institutes of Health, Canadian Institutes of Health Research, Stichting NutsOhra, Netherlands Organisation for Health Research and Development, Physicians' Services Incorporated.
Collapse
|
29
|
Xu DF, Bi FG, Ma CY, Wen ZF, Cai XZ. A systematic review of undisplaced femoral neck fracture treatments for patients over 65 years of age, with a focus on union rates and avascular necrosis. J Orthop Surg Res 2017; 12:28. [PMID: 28187745 PMCID: PMC5301374 DOI: 10.1186/s13018-017-0528-9] [Citation(s) in RCA: 71] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2016] [Accepted: 02/03/2017] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND It remains unclear whether conservative treatment should be used to treat the common undisplaced femoral neck fractures that develop in the elderly. Herein, we systematically review the rates of union and avascular necrosis after conservative and surgical treatment of undisplaced femoral neck fractures. METHODS We searched the EMBASE, PubMed, OVID, Cochrane Library, Web of Science, and Scopus databases for randomized controlled trials or observational studies that assessed the outcomes of conservative or surgical treatments of undisplaced femoral neck fractures. No language or publication year limitation was imposed. Statistical analyses were performed with the aid of the chi-squared test. We evaluated the quality of each publication and the risk of bias. RESULTS Twenty-nine studies involving 5071 patients were ultimately included; 1120 patients were treated conservatively and 3951 surgically. The union rates were 68.8% (642/933) and 92.6% (635/686) in the former and latter groups, respectively (p < 0.001). The avascular necrosis rate in the conservatively treated group was 10.3% (39/380), while it was 7.7% (159/2074) in the surgically treated group (p = 0.09). CONCLUSIONS Surgery to treat undisplaced femoral neck fractures was associated with a higher union rate and a tendency toward less avascular necrosis than conservative treatment.
Collapse
Affiliation(s)
- Dan-Feng Xu
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Jie-fang Road 88, Hangzhou, 310009, People's Republic of China
| | - Fang-Gang Bi
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450001, People's Republic of China
| | - Chi-Yuan Ma
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Jie-fang Road 88, Hangzhou, 310009, People's Republic of China
| | - Zheng-Fa Wen
- Department of Orthopaedic Surgery, The Fourth Affiliated Hospital, School of Medicine, Zhejiang University, Yiwu, 322000, People's Republic of China
| | - Xun-Zi Cai
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Jie-fang Road 88, Hangzhou, 310009, People's Republic of China.
| |
Collapse
|
30
|
Mosseri J, Trinquart L, Nizard R, Ravaud P. Meta-Analysis of a Complex Network of Non-Pharmacological Interventions: The Example of Femoral Neck Fracture. PLoS One 2016; 11:e0146336. [PMID: 26735922 PMCID: PMC4703382 DOI: 10.1371/journal.pone.0146336] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2015] [Accepted: 12/01/2015] [Indexed: 01/26/2023] Open
Abstract
Background Surgical interventions raise specific methodological issues in network meta-analysis (NMA). They are usually multi-component interventions resulting in complex networks of randomized controlled trials (RCTs), with multiple groups and sparse connections. Purpose To illustrate the applicability of the NMA in a complex network of surgical interventions and to prioritize the available interventions according to a clinically relevant outcome. Methods We considered RCTs of treatments for femoral neck fracture in adults. We searched CENTRAL, MEDLINE, EMBASE and ClinicalTrials.gov up to November 2015. Two reviewers independently selected trials, extracted data and used the Cochrane Collaboration’s tool for assessing the risk of bias. A group of orthopedic surgeons grouped similar but not identical interventions under the same node. We synthesized the network using a Bayesian network meta-analysis model. We derived posterior odds ratios (ORs) and 95% credible intervals (95% CrIs) for all possible pairwise comparisons. The primary outcome was all-cause revision surgery. Results Data from 27 trials were combined, for 4,186 participants (72% women, mean age 80 years, 95% displaced fractures). The median follow-up was 2 years. With hemiarthroplasty (HA) and total hip arthroplasty (THA) as a comparison, risk of surgical revision was significantly higher with the treatments unthreaded cervical osteosynthesis (OR 8.0 [95% CrI 3.6–15.5] and 5.9 [2.4–12.0], respectively), screw (9.4 [6.0–16.5] and 6.7 [3.9–13.6]) and plate (12.5 [5.8–23.8] and 7.8 [3.8–19.4]). Conclusions In older women with displaced femoral neck fractures, arthroplasty (HA and THA) is the most effective treatment in terms of risk of revision surgery. Systematic Review Registration PROSPERO no. CRD42013004218. Level of Evidence Network Meta-Analysis, Level 1.
Collapse
Affiliation(s)
- Jonathan Mosseri
- INSERM U1153, Paris, France
- Assistance Publique-Hôpitaux de Paris, Hôpital Lariboisière, Service de Chirurgie orthopédique et traumatologique, Paris, France
- Université Paris Diderot, Paris, France
| | - Ludovic Trinquart
- INSERM U1153, Paris, France
- Assistance Publique-Hôpitaux de Paris, Hôpital Hôtel-Dieu, Centre d’épidémiologie clinique, Paris, France
- French Cochrane Centre, Paris, France
- Université Paris Descartes–Sorbonne Paris cité, Paris, France
- Columbia University, Mailman School of Public Health, Department of Epidemiology, New York, United States of America
- * E-mail:
| | - Rémy Nizard
- Assistance Publique-Hôpitaux de Paris, Hôpital Lariboisière, Service de Chirurgie orthopédique et traumatologique, Paris, France
- Université Paris Diderot, Paris, France
| | - Philippe Ravaud
- INSERM U1153, Paris, France
- Assistance Publique-Hôpitaux de Paris, Hôpital Hôtel-Dieu, Centre d’épidémiologie clinique, Paris, France
- French Cochrane Centre, Paris, France
- Université Paris Descartes–Sorbonne Paris cité, Paris, France
- Columbia University, Mailman School of Public Health, Department of Epidemiology, New York, United States of America
| |
Collapse
|
31
|
Park BJ, Cho HM, Min WB. Surgical Treatment of Undisplaced Femur Neck Fractures in Dementia Patients Using Proximal Femoral Nail Antirotation. Hip Pelvis 2015; 27:164-72. [PMID: 27536620 PMCID: PMC4972721 DOI: 10.5371/hp.2015.27.3.164] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2015] [Revised: 08/02/2015] [Accepted: 08/26/2015] [Indexed: 12/22/2022] Open
Abstract
Purpose People with dementia have poor mobility and discharge outcomes following hip fractures. The purpose of this study was to evaluate the clinical and radiological results of internal fixation of undisplaced femur neck fractures (Garden types 1 and 2) by proximal femoral nail antirotation (PFNA) in dementia patients. Materials and Methods We studied retrospectively 19 patients with undisplaced femur neck fracture. All patients were over 70 years of age, walked independently with a cane or crutches and suffered moderate-to-severe dementia. Patients were treated with PFNA and followed-up for more than 2 years. Revision, loss of fixation, complications, and walking ability outcomes were measured. Results In walking-ability evaluation, patients showed an average decrease of just 0.2 points at the final follow-up. Walking ability was evaluated from before injury to 4 weeks after surgery and decreased by less than 0.5 points. Radiological bone union was achieved in 17 cases; the average time to bone union was 4.14 months (range, 2.5-7 months). Complications included non-union in two cases and femoral head avascular necrosis in one case of non-union. Conclusion We found that for patients with osteoporotic bone tissues in their femoral heads or patients (e.g., those suffering dementia) for whom cooperating with medical workers for postoperative walking control or rehabilitation exercises is difficult, implanting a mechanically stable spiral blade for fixation of femoral neck fractures could facilitate walking after surgery.
Collapse
Affiliation(s)
- Bong-Ju Park
- Department of Orthopedic Surgery, Gwangju Veterans Hospital, Gwangju, Korea
| | - Hong-Man Cho
- Department of Orthopedic Surgery, Gwangju Veterans Hospital, Gwangju, Korea
| | - Woong-Bae Min
- Department of Orthopedic Surgery, Gwangju Veterans Hospital, Gwangju, Korea
| |
Collapse
|
32
|
Okcu G, Özkayın N, Erkan S, Tosyali HK, Aktuğlu K. Should full threaded compression screws be used in adult femoral neck fractures? Injury 2015; 46 Suppl 2:S24-8. [PMID: 26021662 DOI: 10.1016/j.injury.2015.05.028] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Operative treatment consisting of fracture reduction and fixation, or arthroplasty to permit early patient mobilization, continues to be the treatment of choice for most femoral neck fractures. Options for internal fixation have included a variety of implants; however most recent reports and textbooks cite parallel multiple cancellous screws as the surgical technique of choice. METHODS The study was prospective, randomized and IRB approved. Inclusion criteria included skeletal maturity, closed femoral neck fracture without concomitant fractures or injuries with complete charts and adequate radiographs obtained from the initial injury till the last follow-up. Forty-four patients were enrolled in this study during one-year period at two university centers. 22 were randomized to be treated with full threaded, cannulated compression screws (Acutrak 6/7, ACUMED) (Group 1) and the other 22 with 16mm partial threaded, 6.5mm or 7.3mm cannulated screws (SYNTHES) (Group 2). Three or four screws were used in both groups according to fracture type and surgeon's preference. Data evaluated included surgical time, fluoroscopy time, fracture type, radiological outcome, complications and functional status using the Harris Hip Score. RESULTS Both groups were comparable in terms of age and gender. There was not a significant difference in terms of surgical time, follow-up period, fracture type, or fluoroscopy time. There were eight complications in Group 1 and two in Group 2 (P=0.049) Time to union was significantly longer in Group 1 (P=0.001). However, Hip Scores were not significantly different in both groups (P=0.20). CONCLUSION When compared with full threaded compression screws, partial-threaded cannulated screws provides a shorter union time and less complication rate while providing equivalent functional results in adult femoral neck fractures.
Collapse
Affiliation(s)
- Güvenir Okcu
- Celal Bayar University, Faculty of Medicine, Department of Orthopaedics and Traumatology, Manisa, Turkey.
| | - Nadir Özkayın
- Ege University, Faculty of Medicine, Department of Orthopaedics and Traumatology, İzmir, Turkey
| | - Serkan Erkan
- Celal Bayar University, Faculty of Medicine, Department of Orthopaedics and Traumatology, Manisa, Turkey
| | - H Koray Tosyali
- Bozyaka Education and Research Hospital, Department of Orthopaedics and Traumatology, İzmir, Turkey
| | - Kemal Aktuğlu
- Ege University, Faculty of Medicine, Department of Orthopaedics and Traumatology, İzmir, Turkey
| |
Collapse
|
33
|
Matharu GS, Shahid M, Pynsent PB, Rowlands T. Accuracy and awareness of lag screw placement when using the dynamic hip screw for fracture fixation. TRAUMA-ENGLAND 2015. [DOI: 10.1177/1460408614542893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Introduction Correct lag screw placement in the femoral head is important to prevent screw cut-out following dynamic hip screw (DHS) fracture fixation. The aim of the study was to determine the accuracy and awareness of lag screw placement when using the DHS for fracture fixation. Patients and methods A retrospective radiographic review of 238 DHS procedures (mean age 81.1 years; 76% female) performed at one centre was undertaken to determine the proportion of lag screws placed correctly (tip–apex distance (TAD) less than 25 mm and central femoral head lag screw position in both radiographic views). A questionnaire was also distributed to 102 orthopaedic surgeons to assess awareness of correct lag screw placement. Results Mean TAD for 238 procedures was 17.2 mm with specialist registrars performing 74%. Lag screws were correctly placed in 80% ( n = 190) with correct placement independent of surgeon grade ( p = 0.418), AO fracture classification ( p = 0.306) and contralateral femoral neck-shaft angle ( p = 0.748). This remained unchanged when 17 lag screws meeting the recommendations, but with an inferior position on the anteroposterior radiograph, were included as correctly placed. Surgeons correctly defined TAD, stated the recommended TAD and measured TAD correctly in 81%, 81% and 57%, respectively. Correct responses were independent of surgeon grade and number of procedures performed. Conclusions Although most lag screws were placed correctly, the questionnaire revealed that almost half of surgeons measured TAD incorrectly. Educating surgeons on the concepts related to correct lag screw placement and acquiring technical skills using surgical simulators may reduce the risk of screw cut-out in their practice.
Collapse
Affiliation(s)
- Gulraj S Matharu
- Queen Elizabeth Hospital, Birmingham, West Midlands, UK
- Royal Orthopaedic Hospital, Birmingham, West Midlands, UK
| | | | - Paul B Pynsent
- Royal Orthopaedic Hospital, Birmingham, West Midlands, UK
| | - Tom Rowlands
- Queen Elizabeth Hospital, Birmingham, West Midlands, UK
| |
Collapse
|
34
|
Pauyo T, Drager J, Albers A, Harvey EJ. Management of femoral neck fractures in the young patient: A critical analysis review. World J Orthop 2014; 5:204-217. [PMID: 25035822 PMCID: PMC4095012 DOI: 10.5312/wjo.v5.i3.204] [Citation(s) in RCA: 89] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2013] [Revised: 04/17/2014] [Accepted: 05/29/2014] [Indexed: 02/06/2023] Open
Abstract
Femoral neck fractures account for nearly half of all hip fractures with the vast majority occurring in elderly patients after simple falls. Currently there may be sufficient evidence to support the routine use of hip replacement surgery for low demand elderly patients in all but non-displaced and valgus impacted femoral neck fractures. However, for the physiologically young patients, preservation of the natural hip anatomy and mechanics is a priority in management because of their high functional demands. The biomechanical challenges of femoral neck fixation and the vulnerability of the femoral head blood supply lead to a high incidence of non-union and osteonecrosis of the femoral head after internal fixation of displaced femoral neck fractures. Anatomic reduction and stable internal fixation are essentials in achieving the goals of treatment in this young patient population. Furthermore, other management variables such as surgical timing, the role of capsulotomy and the choice of implant for fixation remain controversial. This review will focus both on the demographics and injury profile of young patients with femoral neck fractures and the current evidence behind the surgical management of these injuries as well as their major secondary complications.
Collapse
|