1
|
Pan L, Hong Y, Zhong X, He J, Zhang Z, Zhao Q, Bai L, Ma M, Duan J. A Novel Scale to Assess Humidification during Noninvasive Ventilation: A Prospective Observational Study. Can Respir J 2023; 2023:9958707. [PMID: 38179551 PMCID: PMC10766471 DOI: 10.1155/2023/9958707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 09/02/2023] [Accepted: 12/20/2023] [Indexed: 01/06/2024] Open
Abstract
Objective To develop a novel scale to assess humidification during noninvasive ventilation (NIV). Methods This study was performed in an ICU of a teaching hospital. Three ICU practitioners with more than 10 years of clinical experience developed an oral humidification scale with a range of 1-4 points. Each studied the current literature on humidification and examined 50 images of mouths of NIV patients with different levels of humidification. Then, through discussion, a consensus scale was developed. Next, 10 practitioners and 33 NIV patients were recruited to validate the scale. Finally, the patients rated the dryness of their mouths using the 1-4 visual scale just after the practitioners' assessment. Talking and discussion were forbidden during the assessment, and the scorers were blinded to each other. Results We performed 36 assessments in 33 NIV patients. Three patients were assessed twice each more than 2 days apart. The interitem correlation coefficients between the 10 practitioners ranged from 0.748 to 0.917. Fleiss's kappa statistic was 0.516, indicating moderate agreement among practitioners. Of the 33 patients, 5 (15%) were unable to make an assessment using the 1-4 visual scale. Among the remainder, 55.7% provided scores that matched those given by the practitioners; 13.7% of scores were 1 point higher than that rated by the practitioners, and 20.7% were 1 point lower. Only 10% were beyond a 1-point difference. The kappa coefficient was 0.483 between patients and practitioners. Conclusions The oral humidification scale showed moderate agreement between practitioners. It was also highly accurate in reflecting the level of humidification assessed by patients.
Collapse
Affiliation(s)
- Longfang Pan
- Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
| | - Yueling Hong
- Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
| | - Xiaoqing Zhong
- Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
| | - Jiao He
- Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
| | - Zuli Zhang
- Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
| | - Qianru Zhao
- Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
| | - Linfu Bai
- Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
| | - Mengyi Ma
- Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
| | - Jun Duan
- Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
| |
Collapse
|
2
|
Mansell SK, Devani N, Shah A, Schievano S, Main E, Mandal S. Current treatment strategies in managing side effects associated with domiciliary positive airway pressure (PAP) therapy for patients with sleep disordered breathing: A systematic review and meta-analysis. Sleep Med Rev 2023; 72:101850. [PMID: 37812972 DOI: 10.1016/j.smrv.2023.101850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 08/25/2023] [Accepted: 09/12/2023] [Indexed: 10/11/2023]
Abstract
Sleep disordered breathing is commonly treated with positive airway pressure therapy. Positive airway pressure therapy is delivered via a tight-fitting mask with common side effects including: leak, ineffective treatment, residual sleep disordered breathing, eye irritation, nasal congestion, pressure ulcers and poor concordance with therapy. This systematic review and meta-analysis aimed to identify the effectiveness of current treatment strategies for managing side effects associated with positive airway pressure therapy. Five databases were searched and 10,809 articles were screened, with 36 articles included in the review. Studies investigated: dressings, nasal spray/douche, chin straps, heated humidification and interfaces. No intervention either improved or detrimentally affected: positive airway pressure concordance, Epworth Sleepiness Score, residual apnoea hypopnea index or interface leak. The review was limited by study heterogeneity, particularly for outcome measures. Additionally, patient demographics were not reported, making it difficult to apply the findings to a broad clinical population. This review highlights the paucity of evidence supporting treatment strategies to manage side effects of positive airway pressure therapy.
Collapse
Affiliation(s)
| | | | - Amar Shah
- University College London, UK; Royal Free London NHS Foundation Trust, UK
| | | | | | - Swapna Mandal
- University College London, UK; Royal Free London NHS Foundation Trust, UK
| |
Collapse
|
3
|
Hu Y, Zhang Z, Fang F, Yang J, Ma J, Hu S, Guan J. Effects of heated humidification on positive airway pressure side effects in patients with obstructive sleep apnoea: a meta-analysis. Sleep Breath 2023; 27:67-75. [PMID: 35347658 DOI: 10.1007/s11325-022-02596-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Revised: 02/24/2022] [Accepted: 03/10/2022] [Indexed: 11/25/2022]
Abstract
PURPOSE An earlier study found that heated humidification reduced the side effects of positive airway pressure (PAP) in patients with obstructive sleep apnoea (OSA). However, other studies disagreed with this finding. Therefore, we evaluated the relationship between heated humidification and the side effects of PAP in patients with OSA. METHODS According to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, six databases were searched for relevant randomised controlled trials (RCTs) performed from January 1999 to June 2021. RESULTS From 1012 retrieved articles, we identified 9 eligible RCTs. Compared to the control group, the heated humidification group reported improvements in dry nose (pooled standardised mean difference [SMD] = - 0.70, 95% confidence interval [CI] = - 0.96 to - 0.45, I2 = 0%, p < 0.00001), blocked nose (SMD = - 0.47, 95%CI - 0.69 to - 0.25, I2 = 36%, p < 0.0001), runny nose (SMD = - 0.22, 95%CI - 0.44 to 0, I2 = 0%, p = 0.05), dry mouth (SMD = - 0.62, 95%CI - 0.87 to - 0.37, I2 = 0%, p < 0.00001), and dry throat (SMD = - 0.61, 95%CI - 0.90 to - 0.33, I2 = 41%, p < 0.0001), but did not enhance positive airway pressure adherence (pooled mean difference [MD] = 0.24, 95% CI - 0.10 to 0.58, I2 = 0%, p = 0.17). CONCLUSIONS Heated humidification improved some PAP side effects in patients with OSA but did not increase PAP adherence. Additional large-scale multi-centre RCTs are needed to verify the long-term effects.
Collapse
Affiliation(s)
- Yuli Hu
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Xuhui District, Shanghai, China
- Shanghai Key Laboratory of Sleep Disordered Breathing, Shanghai, China
| | - Zuoyan Zhang
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Xuhui District, Shanghai, China
| | - Fang Fang
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Xuhui District, Shanghai, China
- Shanghai Key Laboratory of Sleep Disordered Breathing, Shanghai, China
| | - Jiaxin Yang
- School of Nursing, Soochow University, Suzhou, China
| | - Jun Ma
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Xuhui District, Shanghai, China
| | - Sanlian Hu
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Xuhui District, Shanghai, China.
| | - Jian Guan
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Xuhui District, Shanghai, China.
- Shanghai Key Laboratory of Sleep Disordered Breathing, Shanghai, China.
| |
Collapse
|
4
|
Fujino Y, Oka Y, Wakamura T. Seasonal effects on the continuous positive airway pressure adherence of patients with obstructive sleep apnea. Sleep Med 2021; 80:126-133. [PMID: 33596526 DOI: 10.1016/j.sleep.2021.01.024] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 01/12/2021] [Accepted: 01/15/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE This study examined seasonal differences in continuous positive airway pressure (CPAP) therapy adherence among patients with obstructive sleep apnea (OSA). METHODS Patients aged ≥20 years with OSA who had used CPAP devices on the automatic setting for >12 consecutive months (n = 141) were included in this retrospective study from December 2015-2016. The information of CPAP use (pressure, hours of actual use) was extracted from database downloaded from patients' CPAP devices. Patients were divided into adherent and non-adherent groups using the cutoff point of 70% CPAP use for ≥4 h daily over the 1-year study period. CPAP use data were averaged for each season. RESULTS Patients in the adherent group were significantly older than those in the non-adherent group (p < 0.001). In the adherent group, the rate of ≥4 h daily CPAP use was significantly lower, the daily duration of CPAP use was significantly shorter, and the residual apnea-hypopnea index (AHI; events/hour) was significantly higher in summer than in other seasons (all p < 0.001). In the non-adherent group, the duration of daily CPAP use and the AHI differed significantly between winter and summer (p = 0.008 and p < 0.001, respectively). CONCLUSIONS Seasonal changes were associated with the CPAP adherence of patients with OSA. The study findings suggest that there is possibility of increasing the duration of CPAP use by adjusting the bedroom environment in hot and humid seasons.
Collapse
Affiliation(s)
- Yoko Fujino
- Environmental Health Nursing, Human Health Sciences, Graduate School of Medicine, Kyoto University, 53, Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan; Center for Sleep Medicine, Ehime University Hospital, 454, Toon-city, Ehime, 791-0204, Japan.
| | - Yasunori Oka
- Center for Sleep Medicine, Ehime University Hospital, 454, Toon-city, Ehime, 791-0204, Japan
| | - Tomoko Wakamura
- Environmental Health Nursing, Human Health Sciences, Graduate School of Medicine, Kyoto University, 53, Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| |
Collapse
|
5
|
Hill EA, Fairley DM, Williams LJ, Spanò G, Cooper SA, Riha RL. Prospective Trial of CPAP in Community-Dwelling Adults with Down Syndrome and Obstructive Sleep Apnea Syndrome. Brain Sci 2020; 10:E844. [PMID: 33198148 PMCID: PMC7696635 DOI: 10.3390/brainsci10110844] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 10/31/2020] [Accepted: 11/05/2020] [Indexed: 11/30/2022] Open
Abstract
Adults with Down syndrome (DS) are predisposed to obstructive sleep apnoea (OSA), but the effectiveness and acceptability of continuous positive airway pressure treatment (CPAP) in this group has rarely been formally assessed. This study was designed as a pilot randomised, parallel controlled trial for one month, continuing as an uncontrolled cohort study whereby the control group also received the intervention. Symptomatic, community-dwelling DS individuals exhibiting ≥10 apnoeas/hypopneas per hour in bed on a Type 3 home sleep study were invited to participate in this study, with follow-up at 1, 3, 6, and 12 months from baseline. Measurements of sleepiness, behaviour, cognitive function and general health were undertaken; the primary outcome was a change in the pictorial Epworth Sleepiness Scale (pESS) score. Twenty-eight participants (19 male) were enrolled: age 28 ± 9 year; body mass index 31.5 ± 7.9 kg/m2; 39.6 ± 32.2 apnoeas/hypopneas per hour in bed; pESS 11 ± 6/24. The pilot randomised controlled trial at one month demonstrated no change between the groups. At 12 months, participant (p = 0.001) pESS and Disruptive (p < 0.0001), Anxiety/Antisocial (p = 0.024), and Depressive (p = 0.008) behaviour scores were reduced compared to baseline. Improvement was noted in verbal (p = 0.001) and nonverbal intelligence scores (p = 0.011). General health scores also improved (p = 0.02). At the end of the trial, 19 participants continued on treatment. Use of CPAP in adults with DS and OSA led to a number of significant, sustained improvements in sleepiness and behavioural/emotional outcomes at 12 months.
Collapse
Affiliation(s)
- Elizabeth A Hill
- Sleep Research Unit, Centre for Clinical Brain Sciences, University of Edinburgh, 51 Little France Crescent, Edinburgh EH16 4SA, UK; (E.A.H.); (D.M.F.)
| | - Donna M Fairley
- Sleep Research Unit, Centre for Clinical Brain Sciences, University of Edinburgh, 51 Little France Crescent, Edinburgh EH16 4SA, UK; (E.A.H.); (D.M.F.)
| | - Linda J Williams
- Centre for Population Health Sciences, Usher Institute, Old Medical School, University of Edinburgh, Teviot Place, Edinburgh EH8 9AG, UK;
| | - Goffredina Spanò
- Down Syndrome Research Group, Department of Psychology, University of Arizona, Tucson, AZ 85721, USA;
| | - Sally-Ann Cooper
- Mental Health and Wellbeing Research Group, Institute of Health and Wellbeing, University of Glasgow, Glasgow G12 0XH, UK;
| | - Renata L Riha
- Sleep Research Unit, Centre for Clinical Brain Sciences, University of Edinburgh, 51 Little France Crescent, Edinburgh EH16 4SA, UK; (E.A.H.); (D.M.F.)
| |
Collapse
|
6
|
Kennedy B, Lasserson TJ, Wozniak DR, Smith I. Pressure modification or humidification for improving usage of continuous positive airway pressure machines in adults with obstructive sleep apnoea. Cochrane Database Syst Rev 2019; 12:CD003531. [PMID: 31792939 PMCID: PMC6888022 DOI: 10.1002/14651858.cd003531.pub4] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
BACKGROUND Obstructive sleep apnoea (OSA) is the repetitive closure of the upper airway during sleep. This results in disturbed sleep and excessive daytime sleepiness. It is a risk factor for long-term cardiovascular morbidity. Continuous positive airway pressure (CPAP) machines can be applied during sleep. They deliver air pressure by a nasal or oronasal mask to prevent the airway from closing, reducing sleep disturbance and improving sleep quality. Some people find them difficult to tolerate because of high pressure levels and other symptoms such as a dry mouth. Switching to machines that vary the level of air pressure required to reduce sleep disturbance could increase comfort and promote more regular use. Humidification devices humidify the air that is delivered to the upper airway through the CPAP circuit. Humidification may reduce dryness of the throat and mouth and thus improve CPAP tolerability. This updated Cochrane Review looks at modifying the delivery of positive pressure and humidification on machine usage and other clinical outcomes in OSA. OBJECTIVES To determine the effects of positive pressure modification or humidification on increasing CPAP machine usage in adults with OSA. SEARCH METHODS We searched Cochrane Airways Specialised Register and clinical trials registries on 15 October 2018. SELECTION CRITERIA Randomised parallel group or cross-over trials in adults with OSA. We included studies that compared automatically adjusting CPAP (auto-CPAP), bilevel positive airway pressure (bi-PAP), CPAP with expiratory pressure relief (CPAPexp), heated humidification plus fixed CPAP, automatically adjusting CPAP with expiratory pressure relief, Bi-PAP with expiratory pressure relief, auto bi-PAP and CPAPexp with wakefulness detection with fixed pressure setting. DATA COLLECTION AND ANALYSIS We used standard methods expected by Cochrane. We assessed the certainty of evidence using GRADE for the outcomes of machine usage, symptoms (measured by the Epworth Sleepiness Scale (ESS)), Apnoea Hypopnoea Index (AHI), quality of life measured by Functional Outcomes of Sleep Questionnaire (FOSQ), blood pressure, withdrawals and adverse events (e.g. nasal blockage or mask intolerance). The main comparison of interest in the review is auto-CPAP versus fixed CPAP. MAIN RESULTS We included 64 studies (3922 participants, 75% male). The main comparison of auto-CPAP with fixed CPAP is based on 36 studies with 2135 participants from Europe, USA, Hong Kong and Australia. The majority of studies recruited participants who were recently diagnosed with OSA and had not used CPAP previously. They had excessive sleepiness (ESS: 13), severe sleep disturbance (AHI ranged from 22 to 59), and average body mass index (BMI) of 35 kg/m2. Interventions were delivered at home and the duration of most studies was 12 weeks or less. We judged that studies at high or unclear risk of bias likely influenced the effect of auto-CPAP on machine usage, symptoms, quality of life and tolerability, but not for other outcomes. Primary outcome Compared with average usage of about five hours per night with fixed CPAP, people probably use auto-CPAP for 13 minutes longer per night at about six weeks (mean difference (MD) 0.21 hours/night, 95% confidence interval (CI) 0.11 to 0.31; 31 studies, 1452 participants; moderate-certainty evidence). We do not have enough data to determine whether auto-CPAP increases the number of people who use machines for more than four hours per night compared with fixed CPAP (odds ratio (OR) 1.16, 95% CI 0.75 to 1.81; 2 studies, 346 participants; low-certainty evidence). Secondary outcomes Auto-CPAP probably reduces daytime sleepiness compared with fixed CPAP at about six weeks by a small amount (MD -0.44 ESS units, 95% CI -0.72 to -0.16; 25 studies, 1285 participants; moderate-certainty evidence). AHI is slightly higher with auto-CPAP than with fixed CPAP (MD 0.48 events per hour, 95% CI 0.16 to 0.80; 26 studies, 1256 participants; high-certainty evidence), although it fell with both machine types from baseline values in the studies. Ten per cent of people in auto-CPAP and 11% in the fixed CPAP arms withdrew from the studies (OR 0.90, 95% CI 0.64 to 1.27; moderate-certainty evidence). Auto-CPAP and fixed CPAP may have similar effects on quality of life, as measured by the FOSQ but more evidence is needed to be confident in this result (MD 0.12, 95% CI -0.21 to 0.46; 3 studies, 352 participants; low-certainty evidence). Two studies (353 participants) provided data on clinic-measured blood pressure. Auto-CPAP may be slightly less effective at reducing diastolic blood pressure compared to fixed CPAP (MD 2.92 mmHg, 95% CI 1.06 to 4.77 mmHg; low-certainty evidence). The two modalities of CPAP probably do not differ in their effects on systolic blood pressure (MD 1.87 mmHg, 95% CI -1.08 to 4.82; moderate-certainty evidence). Nine studies (574 participants) provided information on adverse events such as nasal blockage, dry mouth, tolerance of treatment pressure and mask leak. They used different scales to capture these outcomes and due to variation in the direction and size of effect between the studies, the comparative effects on tolerability outcomes are uncertain (very low-certainty evidence). The evidence base for other interventions is smaller, and does not provide sufficient information to determine whether there are important differences between pressure modification strategies and fixed CPAP on machine usage outcomes, symptoms and quality of life. As with the evidence for the auto-CPAP, adverse events are measured disparately. AUTHORS' CONCLUSIONS In adults with moderate to severe sleep apnoea starting positive airway pressure therapy, auto-CPAP probably increases machine usage by about 13 minutes per night. The effects on daytime sleepiness scores with auto-CPAP are not clinically meaningful. AHI values are slightly lower with fixed CPAP. Use of validated quality of life instruments in the studies to date has been limited, although where they have been used the effect sizes have not exceeded proposed clinically important differences. The adoption of a standardised approach to measuring tolerability would help decision-makers to balance benefits with harms from the different treatment options available. The evidence available for other pressure modification strategies does not provide a reliable basis on which to draw firm conclusions. Future studies should look at the effects of pressure modification devices and humidification in people who have already used CPAP but are unable to persist with treatment.
Collapse
Affiliation(s)
- Barry Kennedy
- St. James's HospitalDepartment of Sleep MedicineDublinIreland
| | - Toby J Lasserson
- Cochrane Central ExecutiveEditorial & Methods DepartmentSt Albans House57‐59 HaymarketLondonUKSW1Y 4QX
| | - Dariusz R Wozniak
- Royal Papworth HospitalRespiratory Support and Sleep CentrePapworth EverardCambridgeUKCB23 3RE
| | - Ian Smith
- Royal Papworth HospitalRespiratory Support and Sleep CentrePapworth EverardCambridgeUKCB23 3RE
| | | |
Collapse
|
7
|
Patil SP, Ayappa IA, Caples SM, Kimoff RJ, Patel SR, Harrod CG. Treatment of Adult Obstructive Sleep Apnea With Positive Airway Pressure: An American Academy of Sleep Medicine Systematic Review, Meta-Analysis, and GRADE Assessment. J Clin Sleep Med 2019; 15:301-334. [PMID: 30736888 DOI: 10.5664/jcsm.7638] [Citation(s) in RCA: 352] [Impact Index Per Article: 70.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Accepted: 01/14/2019] [Indexed: 02/07/2023]
Abstract
INTRODUCTION The purpose of this systematic review is to provide supporting evidence for the clinical practice guideline for the treatment of obstructive sleep apnea (OSA) in adults using positive airway pressure (PAP). METHODS The American Academy of Sleep Medicine commissioned a task force of experts in sleep medicine. A systematic review was conducted to identify studies that compared the use of PAP with no treatment as well as studies that compared different PAP modalities. Meta-analyses were performed to determine the clinical significance of using PAP in several modalities (ie, continuous PAP, auto-adjusting PAP, and bilevel PAP), to treat OSA in adults. In addition, meta-analyses were performed to determine the clinical significance of using an in-laboratory versus ambulatory strategy for the initiation of PAP, educational and behavioral interventions, telemonitoring, humidification, different mask interfaces, and flexible or modified pressure profile PAP in conjunction with PAP to treat OSA in adults. Finally, the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) process was used to assess the evidence for making recommendations. RESULTS The literature search resulted in 336 studies that met inclusion criteria; 184 studies provided data suitable for meta-analyses. The data demonstrated that PAP compared to no treatment results in a clinically significant reduction in disease severity, sleepiness, blood pressure, and motor vehicle accidents, and improvement in sleep-related quality of life in adults with OSA. In addition, the initiation of PAP in the home demonstrated equivalent effects on patient outcomes when compared to an in-laboratory titration approach. The data also demonstrated that the use of auto-adjusting or bilevel PAP did not result in clinically significant differences in patient outcomes compared with standard continuous PAP. Furthermore, data demonstrated a clinically significant improvement in PAP adherence with the use of educational, behavioral, troubleshooting, and telemonitoring interventions. Systematic reviews for specific PAP delivery method were also performed and suggested that nasal interfaces compared to oronasal interfaces have improved adherence and slightly greater reductions in OSA severity, heated humidification compared to no humidification reduces some continuous PAP-related side effects, and pressure profile PAP did not result in clinically significant differences in patient outcomes compared with standard continuous PAP.
Collapse
Affiliation(s)
| | - Indu A Ayappa
- Icahn School of Medicine at Mount Sinai, New York, New York
| | | | - R Joh Kimoff
- McGill University Health Centre, Montreal, Quebec, Canada
| | | | | |
Collapse
|
8
|
Heated humidification did not improve compliance of positive airway pressure and subjective daytime sleepiness in obstructive sleep apnea syndrome: A meta-analysis. PLoS One 2018; 13:e0207994. [PMID: 30517168 PMCID: PMC6281237 DOI: 10.1371/journal.pone.0207994] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2017] [Accepted: 11/11/2018] [Indexed: 11/19/2022] Open
Abstract
Introduction We performed a meta-analysis on whether heated humidification during positive airway pressure (PAP) could improve compliance and subjective daytime sleepiness in obstructive sleep apnea syndrome (OSAS) patients. Materials and methods We searched PubMed, EMBASE, Medline, Cochrane Library, Clinical Trials, Web of Science and Scopus from inception to Oct 29, 2017. We made meta-analysis on the all available randomized controlled trials (RCTs) which assessed effects of heated humidification intervention on PAP compliance and subjective daytime sleepiness, by subgroups of automatic adjusting positive airway pressure/ continuous positive airway pressure (APAP/CPAP) usage and patients with/without upper airway symptoms prior to PAP therapy. Results A total of nine RCTs were evaluated finally in this meta-analysis. When all the studies were pooled, heated humidification did not improve PAP usage time [weighted mean difference(WMD) = 13.28, 95% confidence interval(CI): -5.85 to 32.41, P = 0.17] or Epworth sleepiness scale (ESS) score (WMD = -0.63, 95% CI: -1.32 to 0.07, P = 0.08). In terms of PAP usage time, heated humidification failed to enhance compliance in both APAP (WMD = 22.34, 95%CI: -21.08 to 65.77, P = 0.31) or CPAP subgroup (WMD = 11.09, 95%CI: -10.21 to 32.40, P = 0.31) and it was also ineffective among patients with upper airway symptoms prior to PAP therapy (WMD = 22.74, 95% CI: -7.77 to 53.24, P = 0.14) or without (WMD = 13.22, 95%CI: -35.84 to 62.29, P = 0.60). In terms of ESS score, heated humidification did not reduce ESS scores in both APAP (WMD = -1.59, 95% CI: -3.81 to 0.64, P = 0.16) or CPAP subgroup (WMD = -0.39, 95% CI: -1.16 to 0.37, P = 0.32) and it was also helpless among patients with upper airway symptoms prior to PAP therapy (WMD = -1.17, 95% CI: -3.10 to 0.75, P = 0.23) or without (WMD = -0.30, 95%CI: -2.25 to 1.66, P = 0.76). Conclusion Heated humidification during PAP therapy improves neither the compliance nor ESS scores in OSAS patients, no matter what types of PAP or whether the patients had upper airway symptoms prior to PAP therapy. But to the population with upper airway symptoms and the APAP users, the conclusions were limited because of small sample size and possible selection bias. More attentions should be paid to these potentially possible benefited subgroups.
Collapse
|
9
|
Factors influencing adherence to continuous positive airway pressure treatment in obstructive sleep apnea and mortality associated with treatment failure - a national registry-based cohort study. Sleep Med 2018; 51:85-91. [PMID: 30103074 DOI: 10.1016/j.sleep.2018.07.007] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2018] [Revised: 06/21/2018] [Accepted: 07/05/2018] [Indexed: 10/28/2022]
Abstract
OBJECTIVES Adherence to continuous positive airway pressure (CPAP) in patients with obstructive sleep apnea (OSA) is crucial. Our aim was to identify protective and risk factors against the discontinuation of CPAP treatment in patients with OSA and to estimate the mortality risk in those who were non-adherent to CPAP therapy. METHODS This was a registry-based cohort study from 37 centers across Sweden with OSA patients on CPAP in the Swedevox Swedish national registry between July 2010 and March 2017. RESULTS In 16,425 patients (70.8% men) with complete follow-up data after 1.2 ± 0.8 years the adjusted relative risk ratio (aRRR) for the discontinuation of CPAP was 0.57 (95% confidence interval (CI) 0.50-0.65) for use of humidifier, 0.87 (95% CI 0.82-0.92) for increasing age per 10 years, 0.80 (95% CI 0.77-0.83) for increasing apnea hypopnea index (AHI) per 5 units/hour, and 0.96 (95% CI 0.95-0.97) per increased unit on the Epworth Sleepiness Scale (ESS). Increasing BMI was associated with increased adherence up to BMI 35. Women and patients with hypertension ran an increased risk of discontinuing CPAP treatment, aRRR 1.28 (95% CI 1.12-1.46) and 1.24 (95% CI 1.12-1.42) respectively. The adjusted hazard ratio (HR) for mortality was 1.74 (95% CI 1.32-2.28) among those who did not adhere to CPAP (median follow-up period 2.4 years after the one year adherence evaluation). CONCLUSION Use of humidifier is associated with greater adherence to CPAP treatment. Other factors predicting adherence are increasing age, more severe OSA and overweight up to BMI 35, whereas female gender and coexisting hypertension are risk factors for discontinuation of CPAP. Failure to adhere to CPAP is associated with increased mortality.
Collapse
|
10
|
Lebret M, Martinot JB, Arnol N, Zerillo D, Tamisier R, Pepin JL, Borel JC. Factors Contributing to Unintentional Leak During CPAP Treatment: A Systematic Review. Chest 2016; 151:707-719. [PMID: 27986462 DOI: 10.1016/j.chest.2016.11.049] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Revised: 11/09/2016] [Accepted: 11/29/2016] [Indexed: 12/30/2022] Open
Abstract
CPAP is the first-line treatment for moderate to severe OSA syndrome. Up to 25% of patients with OSA syndrome discontinue CPAP treatment due to side effects. Unintentional leakage and its associated annoying consequences are the most frequently reported adverse effects of CPAP. Successive technological improvements have not succeeded in addressing this issue. A systematic review was conducted (1) to assess the impact of different technological advances on unintentional leaks and (2) to determine if any patient characteristics have already been identified as determinants of unintentional leakage. No CPAP modality was superior to another in reducing unintentional leaks and, surprisingly, oronasal masks were associated with higher unintentional leaks. Nasal obstruction, older age, higher BMI, central fat distribution, and male sex might be associated with an increased risk of unintentional leakage. Such leaks remain an important problem. Further studies are needed to improve the understanding of underlying clinical factors so that patients at risk of unintentional leaks may be identified and individualized solutions applied.
Collapse
Affiliation(s)
- Marius Lebret
- Department of Research and Development, Association AGIR à dom, HP2 Laboratory, INSERM U 1042, Meylan, France.
| | | | - Nathalie Arnol
- Department of Research and Development, Association AGIR à dom, HP2 Laboratory, INSERM U 1042, Meylan, France
| | - Daniel Zerillo
- Department of Research and Development, Association AGIR à dom, HP2 Laboratory, INSERM U 1042, Meylan, France
| | - Renaud Tamisier
- Thorax and Vessels Division, Sleep Laboratory, Grenoble Alpes University, HP2 Laboratory, INSERM U 1042, Grenoble, France
| | - Jean-Louis Pepin
- Thorax and Vessels Division, Sleep Laboratory, Grenoble Alpes University, HP2 Laboratory, INSERM U 1042, Grenoble, France
| | - Jean-Christian Borel
- Department of Research and Development, Association AGIR à dom, HP2 Laboratory, INSERM U 1042, Meylan, France; Thorax and Vessels Division, Sleep Laboratory, Grenoble Alpes University, HP2 Laboratory, INSERM U 1042, Grenoble, France
| |
Collapse
|
11
|
White DE, Nates RJ, Bartley J. A pilot study of an in-vitro bovine trachea model of the effect of continuous positive airway pressure breathing on airway surface liquid. Biomed Eng Online 2014; 13:12. [PMID: 24502283 PMCID: PMC3922406 DOI: 10.1186/1475-925x-13-12] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2013] [Accepted: 02/03/2014] [Indexed: 11/10/2022] Open
Abstract
Background Continuous positive air pressure (CPAP) users frequently report troublesome symptoms of airway dryness and nasal congestion. Clinical investigations have demonstrated that supplementary humidification reduces these symptoms but the reason for their occurrence remains unexplained. Investigations using human computational air-conditioning models are unable to reproduce or quantify the apparent airway drying experienced during CPAP therapy. The purpose of this study was to determine whether augmented air pressures change overall mucosal airway surface liquid (ASL) water supply and, if so, the extent of this effect. Method In an original in vitro experimental set up, maximal ASL supply was determined in whole bovine trachea when exposed to simulated tidal breathing stresses over a range of air pressures. Results At ambient pressure, the maximal supply of ASL was found to compare well to previously published data (31.2 μl/cm2.hr). CPAP pressures from 5 cm H2O above ambient were found to reduce ASL supply by 22%. Statistical analysis (n = 8) showed a significant difference existed between the ambient and CPAP results (p < 0.0001), and that there was no significant variation between all pressurized results (p = 0.716). Conclusions These findings provide preliminary data that ASL supply is reduced by CPAP therapy which may explain the airway drying symptoms associated with this therapy.
Collapse
Affiliation(s)
- David E White
- School of Engineering, Auckland University of Technology, Auckland, New Zealand.
| | | | | |
Collapse
|
12
|
Benton ML, Friedman NS. Treatment of obstructive sleep apnea syndrome with nasal positive airway pressure improves golf performance. J Clin Sleep Med 2013; 9:1237-42. [PMID: 24340283 DOI: 10.5664/jcsm.3256] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
STUDY OBJECTIVES Obstructive sleep apnea syndrome (OSAS) is associated with impairment of cognitive function, and improvement is often noted with treatment. Golf is a sport that requires a range of cognitive skills. We evaluated the impact of nasal positive airway pressure (PAP) therapy on the handicap index (HI) of golfers with OSAS. METHODS Golfers underwent a nocturnal polysomnogram (NPSG) to determine whether they had significant OSAS (respiratory disturbance index > 15). Twelve subjects with a positive NPSG were treated with PAP. HI, an Epworth Sleepiness Scale (ESS), and sleep questionnaire (SQ) were submitted upon study entry. After 20 rounds of golf on PAP treatment, the HI was recalculated, and the questionnaires were repeated. A matched control group composed of non-OSAS subjects was studied to assess the impact of the study construct on HI, ESS, and SQ. Statistical comparisons between pre- and post-PAP treatment were calculated. RESULTS The control subjects demonstrated no significant change in HI, ESS, or SQ during this study, while the OSAS group demonstrated a significant drop in average HI (11.3%, p = 0.01), ESS, (p = 0.01), and SQ (p = 0.003). Among the more skilled golfers (defined as HI ≤ 12), the average HI dropped by an even greater degree (31.5%). Average utilization of PAP was 91.4% based on data card reporting. CONCLUSIONS Treatment of OSAS with PAP enhanced performance in golfers with this condition. Treatment adherence was unusually high in this study. Non-medical performance improvement may be a strong motivator for selected subjects with OSAS to seek treatment and maximize adherence.
Collapse
|
13
|
Functional short- and long-term effects of nasal CPAP with and without humidification on the ciliary function of the nasal respiratory epithelium. Sleep Breath 2013; 18:85-93. [PMID: 23657665 DOI: 10.1007/s11325-013-0853-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2012] [Revised: 04/15/2013] [Accepted: 04/18/2013] [Indexed: 10/26/2022]
Abstract
PURPOSE Continuous positive airway pressure (CPAP) is the gold standard in the treatment of obstructive sleep apnea (OSA), but its impact on ciliary function is unclear to date. Furthermore, CPAP is associated with numerous side effects related to the nose and upper airway. Humidified CPAP is used to relieve these symptoms, but again, little is known regarding its effect on ciliary function of the nasal respiratory epithelium. METHODS In this prospective, randomized, crossover trial, 31 patients with OSA (AHI >15/h) were randomized to two treatment arms: nasal continuous positive airway pressure (nCPAP) with humidification or nCPAP without humidification for one night in each modality to assess short-term effects of ciliary beat frequency (CBF) and mucus transport time (MTT) and consecutively for 8 weeks in each modality to assess long-term effects in a crossover fashion. RESULTS The baseline CBF was 4.8 ± 0.6 Hz, and baseline MTT was 540 ± 221 s. After one night of CPAP with and without humidification, ciliary function increased moderately yet with statistical significance (p <0.05). The short-term groups with and without humidification did not differ statistically significant. Regarding long-term effects of CPAP, a statistically significant increase in ciliary function above the baseline level and above the short-term level was shown without humidification (7.2 ± 0.4 Hz; 402 ± 176 s; p <0.01). The increase above baseline level was even more pronounced with humidification (9.3 ± 0.7 Hz; 313 ± 95 s; p <0.01). There was a statistically significant difference between both groups at long-term assessment with regard to CBF (p <0.01). CONCLUSIONS Independent of airway humidification, nCPAP has moderate effects on short-term ciliary function of the nasal respiratory epithelium. However, a significant increase in ciliary function-both in terms of an increased CBF and a decreased MTT-was detected after long-term use. The effect was more pronounced when humidification was used during nCPAP.
Collapse
|
14
|
Heiser C, Sommer J, Stern-Straeter J, Tillmann HC, Hörmann K, Maurer J, Stuck B. Einfluss der Atemluftbefeuchtung auf die Akzeptanz der CPAP-Therapie bei Patienten mit obstruktiver Schlafapnoe. SOMNOLOGIE 2010. [DOI: 10.1007/s11818-010-0488-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
15
|
Hildenbrand T, Weber RK, Brehmer D. Rhinitis sicca, dry nose and atrophic rhinitis: a review of the literature. Eur Arch Otorhinolaryngol 2010; 268:17-26. [DOI: 10.1007/s00405-010-1391-z] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2010] [Accepted: 09/16/2010] [Indexed: 10/19/2022]
|