1
|
Trinh M, Kalloniatis M, Khuu SK, Nivison-Smith L. Retinal sensitivity changes in early/intermediate AMD: a systematic review and meta-analysis of visual field testing under mesopic and scotopic lighting. Eye (Lond) 2024; 38:1827-1835. [PMID: 38499857 PMCID: PMC11229509 DOI: 10.1038/s41433-024-03033-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 01/22/2024] [Accepted: 03/08/2024] [Indexed: 03/20/2024] Open
Abstract
Visual fields under mesopic and scotopic lighting are increasingly being used for macular functional assessment. This review evaluates its statistical significance and clinical relevance, and the optimal testing protocol for early/intermediate age-related macular degeneration (AMD). PubMed and Embase were searched from inception to 14/05/2022. All quality assessments were performed according to GRADE guidelines. The primary outcome was global mean sensitivity (MS), further meta-analysed by: AMD classification scheme, device, test pattern, mesopic/scotopic lighting, stimuli size/chromaticity, pupil dilation, testing radius (area), background luminance, adaptation time, AMD severity, reticular pseudodrusen presence, and follow-up visit. From 1489 studies screened, 42 observational study results contributed to the primary meta-analysis. Supported by moderate GRADE certainty of the evidence, global MS was significantly reduced across all devices under mesopic and scotopic lighting with large effect size (-0.9 [-1.04, -0.75] Hedge's g, P < 0.0001). The device (P < 0.01) and lighting (P < 0.05) used were the only modifiable factors affecting global MS, whereby the mesopic MP-1 and MAIA produced the largest effect sizes and exceeded test-retest variabilities. Global MS was significantly affected by AMD severity (intermediate versus early AMD; -0.58 [-0.88, -0.29] Hedge's g or -2.55 [3.62, -1.47] MAIA-dB) and at follow-up visit (versus baseline; -0.62 [-0.84, -0.41] Hedge's g or -1.61[-2.69, -0.54] MAIA-dB). Magnitudes of retinal sensitivity changes in early/intermediate AMD are clinically relevant for the MP-1 and MAIA devices under mesopic lighting within the central 10° radius. Other factors including pupil dilation and dark adaptation did not significantly affect global MS in early/intermediate AMD.
Collapse
Affiliation(s)
- Matt Trinh
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| | - Michael Kalloniatis
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
- School of Medicine (Optometry), Deakin University, Geelong, VIC, Australia
| | - Sieu K Khuu
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| | - Lisa Nivison-Smith
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia.
| |
Collapse
|
2
|
Trinh M, Kalloniatis M, Nivison-Smith L. Should clinical automated perimetry be considered for routine functional assessment of early/intermediate age-related macular degeneration (AMD)? A systematic review of current literature. Ophthalmic Physiol Opt 2021; 42:161-177. [PMID: 34843120 PMCID: PMC9300202 DOI: 10.1111/opo.12919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 10/19/2021] [Accepted: 10/19/2021] [Indexed: 11/30/2022]
Abstract
Purpose There is growing interest in functional testing for early/intermediate age‐related macular degeneration (iAMD). However, systematic evaluation of existing clinical functional tests is lacking. This systematic review examines evidence for using clinical automated perimetry in routine assessment of early/iAMD. Recent findings PubMed, Web of Science Core Collection, and Embase were searched from inception to October 2020 to answer, is there evidence of visual field defects in early/iAMD, and if so, are early/iAMD visual field defects linked to real‐world patient outcomes? Articles using clinical automated perimetry (commercially accessible and non‐modified devices/protocols) were included. Microperimetry was excluded as this has yet to be incorporated into clinical guidelines. The primary outcome was global visual field indices including mean deviation (MD), pattern standard deviation (PSD), mean sensitivity (MS) and frequency of defects. The secondary outcome was any real‐world patient outcome including quality of life and/or activities of daily living indices. Twenty‐six studies were eligible for inclusion and all studies were observational. There was consistent evidence of worsened MD, PSD, MS and frequency of defects for early/iAMD compared to normal eyes under photopic, low‐photopic and scotopic conditions. Meta‐analysis of studies using standard automated perimetry (SAP) under photopic conditions revealed worsened MD (−1.52dB [−2.27, −0.78 dB]) and MS (−1.47dB [−2, −0.94 dB]) in early/iAMD compared to normal eyes, representing large statistical effect sizes but non‐clinically meaningful reductions. There was insufficient data for meta‐analyses regarding other clinical automated perimetry protocols. Only one study assessed a real‐world patient outcome (on‐road driving performance), with no significant link to visual field outcomes in early/iAMD. Summary Significant reduction of global visual field indices is present in early/iAMD, but not clinically meaningful using SAP under photopic conditions. Translational relevance of visual field outcomes to patient outcomes in early/iAMD remains unclear. Thus, SAP under photopic conditions is unlikely to be useful for routine assessment of early/iAMD.
Collapse
Affiliation(s)
- Matt Trinh
- Centre for Eye Health, University of New South Wales, Sydney, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Michael Kalloniatis
- Centre for Eye Health, University of New South Wales, Sydney, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Lisa Nivison-Smith
- Centre for Eye Health, University of New South Wales, Sydney, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| |
Collapse
|
3
|
Kalloniatis M, Johnston A. Visual Environmental Adaptation Problems of Partially Sighted Children. JOURNAL OF VISUAL IMPAIRMENT & BLINDNESS 2020. [DOI: 10.1177/0145482x9408800308] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
This article reports the results of an analysis of questionnaires administered to partially sighted children and their parents. The aim of the study was to identify the visual environmental adaptation problems (VEAPs) of children who attend regular classrooms but have support from teachers of visually impaired students. In addition to discussing the VEAPs that were found in various areas, the article offers suggestions for adaptive techniques and materials that will help these children function more effectively.
Collapse
Affiliation(s)
- M. Kalloniatis
- Department of Optometry, University of Melbourne, Parkville 3052, Australia
| | | |
Collapse
|
4
|
Ly A, Yapp M, Nivison-Smith L, Assaad N, Hennessy M, Kalloniatis M. Developing prognostic biomarkers in intermediate age-related macular degeneration: their clinical use in predicting progression. Clin Exp Optom 2017; 101:172-181. [PMID: 29136680 DOI: 10.1111/cxo.12624] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Revised: 08/08/2017] [Accepted: 08/08/2017] [Indexed: 12/27/2022] Open
Abstract
Age-related macular degeneration is a common, complex and blinding eye disease. When early and intermediate levels of severity are detected in one or both eyes, there is a wide-ranging 0.4 to 53 per cent risk of progression to advanced disease in five years. In order to maximise visual outcomes for their patients, practising eye-care professionals must be able to stratify patients according to their risk of progression, intervene (for example by recommending smoking cessation or nutritional supplements and Amsler grid self-monitoring in intermediate disease) and monitor accordingly. With the aid of ocular imaging, a range of under-recognised yet meaningful risk factors have been identified. The purpose of this review is to assist the eye-care practitioner in stratifying the risk of progression in intermediate age-related macular degeneration using the range of established and emerging precursory signs that herald loss of vision.
Collapse
Affiliation(s)
- Angelica Ly
- Centre for Eye Health, Sydney, New South Wales, Australia.,School of Optometry and Vision Science, The University of New South Wales, Sydney, New South Wales, Australia
| | - Michael Yapp
- Centre for Eye Health, Sydney, New South Wales, Australia.,School of Optometry and Vision Science, The University of New South Wales, Sydney, New South Wales, Australia
| | - Lisa Nivison-Smith
- Centre for Eye Health, Sydney, New South Wales, Australia.,School of Optometry and Vision Science, The University of New South Wales, Sydney, New South Wales, Australia
| | - Nagi Assaad
- Centre for Eye Health, Sydney, New South Wales, Australia.,Department of Ophthalmology, Prince of Wales Hospital, Sydney, New South Wales, Australia
| | - Michael Hennessy
- Centre for Eye Health, Sydney, New South Wales, Australia.,Department of Ophthalmology, Prince of Wales Hospital, Sydney, New South Wales, Australia
| | - Michael Kalloniatis
- Centre for Eye Health, Sydney, New South Wales, Australia.,School of Optometry and Vision Science, The University of New South Wales, Sydney, New South Wales, Australia
| |
Collapse
|
5
|
Ly A, Nivison-Smith L, Zangerl B, Assaad N, Kalloniatis M. Self-reported optometric practise patterns in age-related macular degeneration. Clin Exp Optom 2017; 100:718-728. [PMID: 28266060 DOI: 10.1111/cxo.12528] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2016] [Revised: 11/18/2016] [Accepted: 12/13/2016] [Indexed: 11/27/2022] Open
Abstract
BACKGROUND The use of advanced imaging in clinical practice is emerging and the use of this technology by optometrists in assessing patients with age-related macular degeneration is of interest. Therefore, this study explored contemporary, self-reported patterns of practice regarding age-related macular degeneration diagnosis and management using a cross-sectional survey of optometrists in Australia and New Zealand. METHODS Practising optometrists were surveyed on four key areas, namely, demographics, clinical skills and experience, assessment and management of age-related macular degeneration. Questions pertaining to self-rated competency, knowledge and attitudes used a five-point Likert scale. RESULTS Completed responses were received from 127 and 87 practising optometrists in Australia and New Zealand, respectively. Advanced imaging showed greater variation in service delivery than traditional techniques (such as slitlamp funduscopy) and trended toward optical coherence tomography, which was routinely performed in age-related macular degeneration by 49 per cent of respondents. Optical coherence tomography was also associated with higher self-rated competency, knowledge and perceived relevance to practice than other modalities. Most respondents (93 per cent) indicated that they regularly applied patient symptoms, case history, visual function results and signs from traditional testing, when queried about their management of patients with age-related macular degeneration. Over half (63 per cent) also considered advanced imaging, while 31 per cent additionally considered all of these as well as the disease stage and clinical guidelines. Contrary to the evidence base, 68 and 34 per cent rated nutritional supplements as highly relevant or relevant in early age-related macular degeneration and normal aging changes, respectively. CONCLUSIONS These results highlight the emergence of multimodal and advanced imaging (especially optical coherence tomography) in the assessment of age-related macular degeneration by optometrists. Clinically significant variations in self-rated test competency and the understanding regarding nutritional supplements for different stages of age-related macular degeneration suggest that further work to up-skill optometrists may be required.
Collapse
Affiliation(s)
- Angelica Ly
- Centre for Eye Health, Sydney, New South Wales, Australia.,School of Optometry and Vision Science, The University of New South Wales, Kensington, New South Wales, Australia
| | - Lisa Nivison-Smith
- Centre for Eye Health, Sydney, New South Wales, Australia.,School of Optometry and Vision Science, The University of New South Wales, Kensington, New South Wales, Australia
| | - Barbara Zangerl
- Centre for Eye Health, Sydney, New South Wales, Australia.,School of Optometry and Vision Science, The University of New South Wales, Kensington, New South Wales, Australia
| | - Nagi Assaad
- Centre for Eye Health, Sydney, New South Wales, Australia.,Department of Ophthalmology, Prince of Wales Hospital, Randwick, New South Wales, Australia
| | - Michael Kalloniatis
- Centre for Eye Health, Sydney, New South Wales, Australia.,School of Optometry and Vision Science, The University of New South Wales, Kensington, New South Wales, Australia
| |
Collapse
|
6
|
Bourne JA. Unravelling the development of the visual cortex: implications for plasticity and repair. J Anat 2010; 217:449-68. [PMID: 20722872 DOI: 10.1111/j.1469-7580.2010.01275.x] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
The visual cortex comprises over 50 areas in the human, each with a specified role and distinct physiology, connectivity and cellular morphology. How these individual areas emerge during development still remains something of a mystery and, although much attention has been paid to the initial stages of the development of the visual cortex, especially its lamination, very little is known about the mechanisms responsible for the arealization and functional organization of this region of the brain. In recent years we have started to discover that it is the interplay of intrinsic (molecular) and extrinsic (afferent connections) cues that are responsible for the maturation of individual areas, and that there is a spatiotemporal sequence in the maturation of the primary visual cortex (striate cortex, V1) and the multiple extrastriate/association areas. Studies in both humans and non-human primates have started to highlight the specific neural underpinnings responsible for the maturation of the visual cortex, and how experience-dependent plasticity and perturbations to the visual system can impact upon its normal development. Furthermore, damage to specific nuclei of the visual cortex, such as the primary visual cortex (V1), is a common occurrence as a result of a stroke, neurotrauma, disease or hypoxia in both neonates and adults alike. However, the consequences of a focal injury differ between the immature and adult brain, with the immature brain demonstrating a higher level of functional resilience. With better techniques for examining specific molecular and connectional changes, we are now starting to uncover the mechanisms responsible for the increased neural plasticity that leads to significant recovery following injury during this early phase of life. Further advances in our understanding of postnatal development/maturation and plasticity observed during early life could offer new strategies to improve outcomes by recapitulating aspects of the developmental program in the adult brain.
Collapse
Affiliation(s)
- James A Bourne
- Australian Regenerative Medicine Institute, Monash University, Clayton, Victoria 3800, Australia.
| |
Collapse
|
7
|
Abstract
In order to better understand the nature of long-wavelength (L) and middle-wavelength (M) cone input into spectral sensitivity functions and determine the reliability with which it is possible to predict L:M cone inputs, we developed analytical methods to determine confidence intervals for L:M cone input for spectral sensitivity functions or data transformed to cone-contrast space. Spectral sensitivity functions measured by direct heterochromatic brightness matches are dominated by the L/M opponent channel over most of the spectral range. For detection of large/ long test stimuli, spectral sensitivity functions show a characteristic "notch" at the adapting wavelength, with the L/M opponent channel dominating most of the spectral range. Flicker increment threshold (FIT) spectral sensitivity functions display many of the characteristics of the luminance flicker mechanism described by Stromeyer et al. (1987). [Vision Research, 27, 1113-1137]. Previous modelling of FIT spectral sensitivity functions proposed a 2:1 L:M cone input for most of testing conditions. We show that FIT spectral sensitivity functions are dominated by L cones but show L cone suppression under bright red adapting fields. For the fitted spectral sensitivity functions or simulated data sets, we found small confidence intervals for L:M cone input into the L/M opponent channel and conclude that it is possible to reliably predict L:M cone input ratios. However, for similar data sets of additive spectral sensitivity functions, we found large confidence intervals for L:M cone input ratios and conclude that it is not possible reliably predict L:M cone input into the L/M non-opponent channel using available spectral sensitivity functions.
Collapse
Affiliation(s)
- M Kalloniatis
- Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia.
| | | |
Collapse
|