Dual SA, Cowger J, Roche E, Nayak A. The Future of Durable Mechanical Circulatory Support: Emerging Technological Innovations and Considerations to Enable Evolution of the Field. J Card Fail 2024; 30:596-609. [PMID: 38431185 DOI: 10.1016/j.cardfail.2024.01.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 01/25/2024] [Accepted: 01/26/2024] [Indexed: 03/05/2024]
Abstract
The field of durable mechanical circulatory support (MCS) has undergone an incredible evolution over the past few decades, resulting in significant improvements in longevity and quality of life for patients with advanced heart failure. Despite these successes, substantial opportunities for further improvements remain, including in pump design and ancillary technology, perioperative and postoperative management, and the overall patient experience. Ideally, durable MCS devices would be fully implantable, automatically controlled, and minimize the need for anticoagulation. Reliable and long-term total artificial hearts for biventricular support would be available; and surgical, perioperative, and postoperative management would be informed by the individual patient phenotype along with computational simulations. In this review, we summarize emerging technological innovations in these areas, focusing primarily on innovations in late preclinical or early clinical phases of study. We highlight important considerations that the MCS community of clinicians, engineers, industry partners, and venture capital investors should consider to sustain the evolution of the field.
Collapse
Affiliation(s)
- Seraina A Dual
- KTH Royal Institute of Technology, Department of Biomedical Engineering and Health Systems, Stockholm, Sweden
| | | | - Ellen Roche
- Massachusetts Institute of Technology, Cambridge, Massachusetts
| | - Aditi Nayak
- Baylor University Medical Center, Dallas, Texas.
| |
Collapse
|
2
|
Maw M, Gross C, Schlöglhofer T, Dimitrov K, Zimpfer D, Moscato F, Schima H. Development of suction detection algorithms for a left ventricular assist device from patient data. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102910] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
3
|
Moscato F, Gross C, Maw M, Schlöglhofer T, Granegger M, Zimpfer D, Schima H. The left ventricular assist device as a patient monitoring system. Ann Cardiothorac Surg 2021; 10:221-232. [PMID: 33842216 PMCID: PMC8033254 DOI: 10.21037/acs-2020-cfmcs-218] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Accepted: 12/15/2020] [Indexed: 11/06/2022]
Abstract
Technological progress of left ventricular assist devices (LVADs) towards rotary blood pumps and the optimization of medical management contributed to the significant improvements in patient survival as well as LVAD support duration. Even though LVAD therapy is now well-established for end-stage heart failure patients, the long-term occurrence of adverse events (AE) such as bleeding, infection or stroke, still represent a relevant burden. An early detection of AE, before onset of major symptoms, can lead to further optimization of patient treatment and thus mitigate the burden of AE. Continuous patient monitoring facilitates identification of pathophysiological states and allows anticipation of AE to improve patient management. In this paper, methods, algorithms and possibilities for continuous patient monitoring based on LVAD data are reviewed. While experience with continuous LVAD monitoring is currently limited to a few centers worldwide, the pace of developments in this field is fast and we expect these technologies to have a global impact on the well-being of LVAD patients.
Collapse
Affiliation(s)
- Francesco Moscato
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria
- Austrian Cluster for Tissue Regeneration, Vienna, Austria
| | - Christoph Gross
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria
| | - Martin Maw
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria
- Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Thomas Schlöglhofer
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria
- Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Marcus Granegger
- Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Daniel Zimpfer
- Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Heinrich Schima
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria
- Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
4
|
Liang L, Meki M, Wang W, Sethu P, El-Baz A, Giridharan GA, Wang Y. A suction index based control system for rotary blood pumps. Biomed Signal Process Control 2020. [DOI: 10.1016/j.bspc.2020.102057] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
5
|
Hemodynamic exercise responses with a continuous-flow left ventricular assist device: Comparison of patients' response and cardiorespiratory simulations. PLoS One 2020; 15:e0229688. [PMID: 32187193 PMCID: PMC7080259 DOI: 10.1371/journal.pone.0229688] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Accepted: 02/11/2020] [Indexed: 12/24/2022] Open
Abstract
Background Left ventricular assist devices (LVADs) are an established treatment for end stage heart failure patients. As LVADs do not currently respond to exercise demands, attention is also directed towards improvements in exercise capacity and resulting quality of life. The aim of this study was to explore hemodynamic responses observed during maximal exercise tests to infer underlying patient status and therefore investigate possible diagnostics from LVAD derived data and advance the development of physiologically adaptive LVAD controllers. Methods High resolution continuous LVAD flow waveforms were recorded from 14 LVAD patients and evaluated at rest and during maximum bicycle exercise tests (n = 24). Responses to exercise were analyzed in terms of an increase (↑) or decrease (↓) in minimum (QMIN), mean (QMEAN), maximum flow (QMAX) and flow pulsatility (QP2P). To interpret clinical data, a cardiorespiratory numerical simulator was used that reproduced patients’ hemodynamics at rest and exercise. Different cardiovascular scenarios including chronotropic and inotropic responses, peripheral vasodilation, and aortic valve pathologies were simulated systematically and compared to the patients’ responses. Results Different patients’ responses to exercise were observed. The most common response was a positive change of ΔQMIN↑ and ΔQP2P↑ from rest to exercise (70% of exercise tests). Two responses, which were never reported in patients so far, were distinguished by QMIN↑ and QP2P↓ (observed in 17%) and by QMIN↓ and QP2P↑ (observed in 13%). The simulations indicated that the QP2P↓ can result from a reduced left ventricular contractility and that the QMIN↓ can occur with a better left ventricular contractility and/or aortic insufficiency. Conclusion LVAD flow waveforms determine a patients’ hemodynamic “fingerprint” from rest to exercise. Different waveform responses to exercise, including previously unobserved ones, were reported. The simulations indicated the left ventricular contractility as a major determinant for the different responses, thus improving patient stratification to identify how patient groups would benefit from exercise-responsive LVAD control.
Collapse
|
6
|
Gross C, Schima H, Schlöglhofer T, Dimitrov K, Maw M, Riebandt J, Wiedemann D, Zimpfer D, Moscato F. Continuous LVAD monitoring reveals high suction rates in clinically stable outpatients. Artif Organs 2020; 44:E251-E262. [PMID: 31945201 PMCID: PMC7318142 DOI: 10.1111/aor.13638] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Revised: 01/08/2020] [Accepted: 01/08/2020] [Indexed: 12/17/2022]
Abstract
Suction of the left ventricle can lead to potentially life‐threatening events in left ventricular assist device (LVAD) patients. With the resolution of currently available clinical LVAD monitoring healthcare professionals are unable to evaluate patients’ suction occurrences in detail. This study investigates occurrences and durations of suction events and their associations with tachycardia in stable outpatients. Continuous high‐resolution LVAD data from HVAD patients were analyzed in the early outpatient period for 15 days. A validated suction detection from LVAD signals was used. Suction events were evaluated as suction rates, bursts of consecutive suction beats, and clusters of suction beats. The occurrence of tachycardia was analyzed before, during, and after suction clusters. Furthermore, blood work, implant strategy, LVAD speed setting, inflow cannula position, left ventricular diameters, and adverse events were evaluated in these patients. LVAD data of 10 patients was analyzed starting at 78 ± 22 postoperative days. Individuals’ highest suction rates per hour resulted in a median of 11% (range 3%‐61%). Bursts categorized as consecutive suction beats with n = 2, n = 3‐5, n = 6‐15, and n > 15 beats were homogenously distributed with 10.3 ± 0.8% among all suction beats. Larger suction bursts were followed by shorter suction‐free periods. Tachycardia during suction occurred in 12% of all suction clusters. Significant differences in clinical parameters between individuals with high and low suction rates were only observed in left ventricular end‐diastolic and end‐systolic diameters (P < .02). Continuous high‐resolution LVAD monitoring sheds light on outpatient suction occurrences. Interindividual and intraindividual characteristics of longitudinal suction rates were observed. Longer suction clusters have higher probabilities of tachycardia within the cluster and more severe types of suction waveforms. This work shows the necessity of improved LVAD monitoring and the implementation of an LVAD speed control to reduce suction rates and their concomitant burden on the cardiovascular system.
Collapse
Affiliation(s)
- Christoph Gross
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Ludwig Boltzmann Institute Cardiovascular Research, Vienna, Austria
| | - Heinrich Schima
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Ludwig Boltzmann Institute Cardiovascular Research, Vienna, Austria.,Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Thomas Schlöglhofer
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Ludwig Boltzmann Institute Cardiovascular Research, Vienna, Austria.,Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Kamen Dimitrov
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Martin Maw
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Ludwig Boltzmann Institute Cardiovascular Research, Vienna, Austria.,Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Julia Riebandt
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Dominik Wiedemann
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Daniel Zimpfer
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Francesco Moscato
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Ludwig Boltzmann Institute Cardiovascular Research, Vienna, Austria
| |
Collapse
|
7
|
Karvounis EC, Tsipouras MG, Tzallas AT, Katertsidis NS, Stefanou K, Goletsis Y, Frigerio M, Verde A, Caruso R, Meyns B, Terrovitis J, Trivella MG, Fotiadis DI. A Decision Support System for the Treatment of Patients with Ventricular Assist Device Support. Methods Inf Med 2018; 53:121-36. [DOI: 10.3414/me13-01-0047] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2013] [Accepted: 01/01/2014] [Indexed: 11/09/2022]
Abstract
SummaryBackground: Heart failure (HF) is affecting millions of people every year and it is characterized by impaired ventricular performance, exercise intolerance and shortened life expectancy. Despite significant advancements in drug therapy, mortality of the disease remains excessively high, as heart transplant remains the gold standard treatment for end-stage HF when no contraindications subsist. Traditionally, implanted Ventricular Assist Devices (VADs) have been employed in order to provide circulatory support to patients who cannot survive the waiting time to transplantation, reducing the workload imposed on the heart. In many cases that process could recover its contractility performance.Objectives: The SensorART platform focuses on the management and remote treatment of patients suffering from HF. It provides an inter-operable, extendable and VAD-independent solution, which incorporates various hardware and software components in a holistic approach, in order to improve the quality of the patients’ treatment and the workflow of the specialists. This paper focuses on the description and analysis of Specialist’s Decision Support System (SDSS), an innovative component of the SensorART platform.Methods: The SDSS is a Web-based tool that assists specialists on designing the therapy plan for their patients before and after VAD implantation, analyzing patients’ data, extracting new knowledge, and making informative decisions.Results: SDSS offers support to medical and VAD experts through the different phases of VAD therapy, incorporating several tools covering all related fields; Statistics, Association Rules, Monitoring, Treatment, Weaning, Speed and Suction Detection.Conclusions: SDSS and its modules have been tested in a number of patients and the results are encouraging.
Collapse
|
8
|
Impeller-pump model derived from conservation laws applied to the simulation of the cardiovascular system coupled to heart-assist pumps. Comput Biol Med 2017; 93:127-138. [PMID: 29304409 DOI: 10.1016/j.compbiomed.2017.12.012] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2017] [Revised: 12/14/2017] [Accepted: 12/16/2017] [Indexed: 11/23/2022]
Abstract
Previous numerical models of impeller pumps for ventricular assist devices utilize curve-fitted polynomials to simulate experimentally-obtained pressure difference versus flow rate characteristics of the pumps, with pump rotational speed as a parameter. In this paper the numerical model for the pump pressure difference versus flow rate characteristics is obtained by analytic derivation. The mass, energy and angular momentum conservation laws are applied to the working fluid passing through the impeller geometry and coupled with the turbomachine's velocity diagram. This results in the construction of a pressure difference versus flow rate characteristic for the specific pump geometry, with pump rotational speed as parameter. Overall this model allows modifications of the pump geometry, so that the pump avoids undesirable operating conditions, such as regurgitant flow. The HeartMate III centrifugal pump is used as an example to demonstrate the application of the technique. The parameterised numerical model for HeartMate III derived by this technique is coupled with a numerical model for the human cardiovascular system, and the combination is used to investigate the cardiovascular response under different conditions of impeller pump support. Conditions resulting in regurgitant pump flow, the pump resulting in aortic valve closure and taking over completely the pumping action from the diseased heart, and inner ventricular wall suction at pump inlet are predicted by the model. The simulation results suggest that for normal HeartMate III operation the pump speed should be maintained between 3,100 and 4,500 rpm to avoid regurgitant pump flow and ventricular suction. To obtain optimal overall cardiovascular system plus pump response, the pump operating speed should be 3,800 rpm.
Collapse
|
9
|
In Vivo Evaluation of Physiologic Control Algorithms for Left Ventricular Assist Devices Based on Left Ventricular Volume or Pressure. ASAIO J 2017; 63:568-577. [DOI: 10.1097/mat.0000000000000533] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
10
|
Granegger M, Aigner P, Haberl T, Mahr S, Tamez DA, Graham J, Nunez NJ, Schima H, Moscato F. Interaction of a Transapical Miniaturized Ventricular Assist Device With the Left Ventricle: Hemodynamic Evaluation and Visualization in an Isolated Heart Setup. Artif Organs 2016; 40:1113-1120. [PMID: 27230977 DOI: 10.1111/aor.12730] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2015] [Revised: 01/20/2016] [Accepted: 01/22/2016] [Indexed: 11/26/2022]
Abstract
New left ventricular assist devices (LVADs) offer both important advantages and potential hazards. VAD development requires better and expeditious ways to identify these advantages and hazards. We validated in an isolated working heart the hemodynamic performance of an intraventricular LVAD and investigated how its outflow cannula interacted with the aortic valve. Hearts from six pigs were explanted and connected to an isolated working heart setup. A miniaturized LVAD was implanted within the left ventricle (tMVAD, HeartWare Inc., Miami Lakes, FL, USA). In four experiments blood was used to investigate hemodynamics under various loading conditions. In two experiments crystalloid perfusate was used, allowing visualization of the outflow cannula within the aortic valve. In all hearts the transapical miniaturized ventricular assist device (tMVAD) implantation was successful. In the blood experiments hemodynamics similar to those observed clinically were achieved. Pump speeds ranged from 9 to 22 krpm with a maximum of 7.6 L/min against a pressure difference between ventricle and aorta of ∼50 mm Hg. With crystalloid perfusate, central positioning of the outflow cannula in the aortic root was observed during full and partial support. With decreasing aortic pressures the cannula tended to drift toward the aortic root wall. The tMVAD could unload the ventricle similarly to LVADs under conventional cannulation. Aortic pressure influenced central positioning of the outflow cannula in the aortic root. The isolated heart is a simple, accessible evaluation platform unaffected by complex reactions within a whole, living animal. This platform allowed detection and visualization of potential hazards.
Collapse
Affiliation(s)
- Marcus Granegger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna.,Ludwig Boltzmann Cluster for Cardiovascular Research
| | - Philipp Aigner
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna.,Ludwig Boltzmann Cluster for Cardiovascular Research
| | - Thomas Haberl
- Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Stephane Mahr
- Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | | | | | | | - Heinrich Schima
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna.,Ludwig Boltzmann Cluster for Cardiovascular Research.,Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Francesco Moscato
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna.,Ludwig Boltzmann Cluster for Cardiovascular Research
| |
Collapse
|
11
|
Physiologic outcome of varying speed rotary blood pump support algorithms: a review study. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2015; 39:13-28. [DOI: 10.1007/s13246-015-0405-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2015] [Accepted: 11/05/2015] [Indexed: 10/22/2022]
|
12
|
Granegger M, Masetti M, Laohasurayodhin R, Schloeglhofer T, Zimpfer D, Schima H, Moscato F. Continuous Monitoring of Aortic Valve Opening in Rotary Blood Pump Patients. IEEE Trans Biomed Eng 2015; 63:1201-7. [PMID: 26461795 DOI: 10.1109/tbme.2015.2489188] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
GOAL Rotary blood pumps (RBPs) typically support the left ventricle by pumping blood from the ventricle to the aorta, partially bypassing the aortic valve (AV). Monitoring the AV opening during RBP support would provide important information about cardiac-pump interaction. However, currently this information is not continuously available. In this study, an algorithm to determine AV opening using available pump signals was evaluated in humans. METHODS Pump speed changes were performed in 15 RBP patients to elicit opening of the AV. Simultaneously to pump data recordings, the AV was continuously monitored using echocardiography. The algorithm, which classifies the AV state utilizing three features (skewness, kurtosis, and crest factor) calculated from the pump flow waveform, was compared to echocardiography by using cross-validation analysis. Additionally, numerical simulation was used to evaluate effects of different pump characteristics and cannula length, as well as mitral valve insufficiency on the AV opening detection method. RESULTS More than 7000 heart beats were analyzed. The correct classification rate using the developed algorithm was 91.1% (sensitivity 91.0%, specificity 91.2%). Numerical simulations showed that the flow waveform shape used for AV opening detection is preserved under the different conditions studied. CONCLUSION This study demonstrates that the AV opening can be reliably detected in RBP patients using available pump data. SIGNIFICANCE Once implemented in RBP controllers, this method will provide a novel tool to improve the management of RBP patients, particularly for adjustments of the pump speed and flow and for the evaluation of the assisted cardiac function.
Collapse
|
13
|
Salamonsen RF, Lim E, Moloney J, Lovell NH, Rosenfeldt FL. Anatomy and Physiology of Left Ventricular Suction Induced by Rotary Blood Pumps. Artif Organs 2015; 39:681-90. [PMID: 26146861 DOI: 10.1111/aor.12550] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
This study in five large greyhound dogs implanted with a VentrAssist left ventricular assist device focused on identification of the precise site and physiological changes induced by or underlying the complication of left ventricular suction. Pressure sensors were placed in left and right atria, proximal and distal left ventricle, and proximal aorta while dual perivascular and tubing ultrasonic flow meters measured blood flow in the aortic root and pump outlet cannula. When suction occurred, end-systolic pressure gradients between proximal and distal regions of the left ventricle on the order of 40-160 mm Hg indicated an occlusive process of variable intensity in the distal ventricle. A variable negative flow difference between end systole and end diastole (0.5-3.4 L/min) was observed. This was presumably mediated by variable apposition of the free and septal walls of the ventricle at the pump inlet cannula orifice which lasted approximately 100 ms. This apposition, by inducing an end-systolic flow deficit, terminated the suction process by relieving the imbalance between pump requirement and delivery from the right ventricle. Immediately preceding this event, however, unnaturally low end-systolic pressures occurred in the left atrium and proximal left ventricle which in four dogs lasted for 80-120 ms. In one dog, however, this collapse progressed to a new level and remained at approximately -5 mm Hg across four heart beats at which point suction was relieved by manual reduction in pump speed. Because these pressures were associated with a pulmonary capillary wedge pressure of -5 mm Hg as well, they indicate total collapse of the entire pulmonary venous system, left atrium, and left ventricle which persisted until pump flow requirement was relieved by reducing pump speed. We suggest that this collapse caused the whole vascular region from pulmonary capillaries to distal left ventricle to behave as a Starling resistance which further reduced right ventricular output thus contributing to a major reduction in pump flow. We contend that similar complications of manual speed control also occur in the human subject and remain a major unsolved problem in the clinical management of patients implanted with rotary blood pumps.
Collapse
Affiliation(s)
- Robert Francis Salamonsen
- Department of Epidemiology and Preventive Medicine, Monash University, Melbourne, Victoria, Australia.,Intensive Care Unit, Alfred Hospital, Melbourne, Victoria, Australia
| | - Einly Lim
- Department of Biomedical Engineering, University of Maya, Kuala Lumpur, Malaysia
| | - John Moloney
- Department of Anesthesia, Monash University, Melbourne, Victoria, Australia.,Department of Anesthesia and Peri-operative Medicine, Alfred Hospital, Melbourne, Victoria, Australia
| | - Nigel Hamilton Lovell
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, New South Wales, Australia
| | - Franklin L Rosenfeldt
- Department of Cardiothoracic Surgery, Alfred Hospital, Melbourne, Victoria, Australia
| |
Collapse
|
14
|
Ooi HL, Seera M, Ng SC, Lim CP, Loo CK, Lovell NH, Redmond SJ, Lim E. Classification of Implantable Rotary Blood Pump States With Class Noise. IEEE J Biomed Health Inform 2015; 20:829-837. [PMID: 25781963 DOI: 10.1109/jbhi.2015.2412375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
A medical case study related to implantable rotary blood pumps is examined. Five classifiers and two ensemble classifiers are applied to process the signals collected from the pumps for the identification of the aortic valve nonopening pump state. In addition to the noise-free datasets, up to 40% class noise has been added to the signals to evaluate the classification performance when mislabeling is present in the classifier training set. In order to ensure a reliable diagnostic model for the identification of the pump states, classifications performed with and without class noise are evaluated. The multilayer perceptron emerged as the best performing classifier for pump state detection due to its high accuracy as well as robustness against class noise.
Collapse
|
15
|
|
16
|
Tzallas AT, Katertsidis NS, Karvounis EC, Tsipouras MG, Rigas G, Goletsis Y, Zielinski K, Fresiello L, Molfetta AD, Ferrari G, Terrovitis JV, Trivella MG, Fotiadis DI. Modeling and simulation of speed selection on left ventricular assist devices. Comput Biol Med 2014; 51:128-39. [DOI: 10.1016/j.compbiomed.2014.04.013] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2014] [Revised: 04/08/2014] [Accepted: 04/16/2014] [Indexed: 11/26/2022]
|
17
|
Evaluating the hemodynamical response of a cardiovascular system under support of a continuous flow left ventricular assist device via numerical modeling and simulations. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2013; 2013:986430. [PMID: 24363780 PMCID: PMC3864087 DOI: 10.1155/2013/986430] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2013] [Revised: 10/19/2013] [Accepted: 10/21/2013] [Indexed: 11/29/2022]
Abstract
Dilated cardiomyopathy is the most common type of the heart failure which can be characterized by impaired ventricular contractility. Mechanical circulatory support devices were introduced into practice for the heart failure patients to bridge the time between the decision to transplant and the actual transplantation which is not sufficient due to the state of donor organ supply. In this study, the hemodynamic response of a cardiovascular system that includes a dilated cardiomyopathic heart under support of a newly developed continuous flow left ventricular assist device—Heart Turcica Axial—was evaluated employing computer simulations. For the evaluation, a numerical model which describes the pressure-flow rate relations of Heart Turcica Axial, a cardiovascular system model describing the healthy and pathological hemodynamics, and a baroreflex model regulating the heart rate were used. Heart Turcica Axial was operated between 8000 rpm and 11000 rpm speeds with 1000 rpm increments for assessing the pump performance and response of the cardiovascular system. The results also give an insight about the range of the possible operating speeds of Heart Turcica Axial in a clinical application. Based on the findings, operating speed of Heart Turcica Axial should be between 10000 rpm and 11000 rpm.
Collapse
|
18
|
Simons AP, Lindelauf AAMA, Ganushchak YM, Maessen JG, Weerwind PW. Efficacy and safety of strategies to preserve stable extracorporeal life support flow during simulated hypovolemia. Perfusion 2013; 29:18-24. [DOI: 10.1177/0267659113502833] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Aim: Without volume-buffering capacity in extracorporeal life support (ELS) systems, hypovolemia can acutely reduce support flow. This study aims at evaluating efficacy and safety of strategies for preserving stable ELS during hypovolemia. Material & Methods: Flow and/or pressure-guided servo pump control, a reserve-driven control strategy and a volume buffer capacity (VBC) device were evaluated with respect to pump flow, venous line pressure and arterial gaseous microemboli (GME) during simulated normovolemia and hypovolemia. Results: Normovolemia resulted in a GME-free pump flow of 3.1±0.0 L/min and a venous line pressure of −10±1 mmHg. Hypovolemia without servo pump control resulted in a GME-loaded flow of 2.3±0.4 L/min with a venous line pressure of −114±52 mmHg. Servo control resulted in an unstable and GME-loaded flow of 1.5±1.2 L/min. With and without servo pump control, the VBC device stabilised flow (SD = 0.2 and 0.0 L/min, respectively) and venous line pressure (SD=51 and 4 mmHg, respectively) with near-absent GME activity. Reserve-driven pump control combined with a VBC device restored a near GME-free flow of 2.7±0.0 L/min with a venous line pressure of −9±0 mmHg. Conclusion: In contrast to a reserve-driven pump control strategy combined with a VBC device, flow and pressure servo control for ELS show evident deficits in preserving stable and safe ELS flow during hypovolemia.
Collapse
Affiliation(s)
- AP Simons
- Department of Cardiothoracic Surgery, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht, the Netherlands
| | - AAMA Lindelauf
- Department of Cardiothoracic Surgery, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht, the Netherlands
| | - YM Ganushchak
- Department of Cardiothoracic Surgery, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht, the Netherlands
| | - JG Maessen
- Department of Cardiothoracic Surgery, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht, the Netherlands
| | - PW Weerwind
- Department of Cardiothoracic Surgery, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht, the Netherlands
| |
Collapse
|
19
|
Moscato F, Granegger M, Edelmayer M, Zimpfer D, Schima H. Continuous monitoring of cardiac rhythms in left ventricular assist device patients. Artif Organs 2013; 38:191-8. [PMID: 23902542 DOI: 10.1111/aor.12141] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Monitoring of cardiac rhythms is of major importance in the treatment of heart failure patients with left ventricular assist devices (LVADs) implanted. A continuous surveillance of these rhythms could improve out-of-hospital care in these patients. The aim of this study was to investigate cardiac rhythms using available pump data only. Datasets (n = 141) obtained in the normal ward, in the intensive care unit, and during bicycle ergometry were analyzed in 11 recipients of a continuous flow LVAD (59.1 ± 9.7 years; male 82%). Tachograms and arrhythmic patterns derived from the pump flow waveform, and a simultaneously recorded ECG were compared, as well as heart rate variability parameters such as: the average heart beat duration (RR interval), the standard deviation of the beat duration (SDNN), the root-mean-square of the difference of successive beat durations (RMSSD), and the number of pairs of adjacent beat duration differing by >50 ms divided by the number of all beats (pNN50). A very good agreement of cardiac rhythm parameters from the pump flow compared with ECG was found. Tachycardia, atrial fibrillation, and extrasystoles could be accurately identified from the tachograms derived from the pump flow. Also, Bland-Altman analysis comparing pump flow with ECG indicated a very small difference in average RR interval of 0.3 ± 1.0 ms, in SSDN of 0.5 ± 2.7 ms, in RMSSD of 1.0 ± 5.6 ms, and in pNN50 of 0.3 ± 1.0%. Continuous monitoring of cardiac rhythms from available pump data is possible. It has the potential to reduce the out-of-hospital diagnostic burden and to permit a more efficient adjustment of the level of mechanical support.
Collapse
Affiliation(s)
- Francesco Moscato
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; Ludwig Boltzmann Cluster for Cardiovascular Research, Vienna, Austria
| | | | | | | | | |
Collapse
|
20
|
Ng SC, Lim E, Mason DG, Avolio AP, Lovell NH. Evaluation of suction detection during different pumping states in an implantable rotary blood pump. Artif Organs 2013; 37:E145-54. [PMID: 23635073 DOI: 10.1111/aor.12079] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In recent times, the problem of noninvasive suction detection for implantable rotary blood pumps has attracted substantial research interest. Here, we compare the performance of various suction indices for different types of suction and non-suction events based on pump speed irregularity. A total of 171 different indices that consist of previously proposed as well as newly introduced suction indices are tested using regularized logistic regression. These indices can be classified as amplitude based (derived from the mean, maximum, and minimum values of a cycle), duration based (derived from the duration of a cycle), gradient based (derived from the first order as well as higher order differences) and frequency based (derived from the power spectral density). The non-suction event data consists of ventricular ejection with or without arrhythmia and intermittent and continuous non-opening of the aortic valve. The suction event data consists of partial ventricular collapse that occurs intermittently as well as continuously with or without arrhythmia. In addition, we also attempted to minimize the usage of multiple indices by applying the sequential forward floating selection method to find which combination of indices gives the best performance. In general, the amplitude-based and gradient-based indices performed quite well while the duration-based and frequency-based indices performed poorly. By having only two indices ([i] the maximum gradient change in positive slope; and [ii] the standard deviation of the maximum value in a cycle), we were able to achieve a sensitivity of 98.9% and a specificity of 99.7%.
Collapse
Affiliation(s)
- Siew-Cheok Ng
- Department of Biomedical Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | | | | | | | | |
Collapse
|
21
|
Wang Y, Simaan MA. A Suction Detection System for Rotary Blood Pumps Based on the Lagrangian Support Vector Machine Algorithm. IEEE J Biomed Health Inform 2013. [DOI: 10.1109/titb.2012.2228877] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
22
|
|
23
|
AlOmari AHH, Savkin AV, Stevens M, Mason DG, Timms DL, Salamonsen RF, Lovell NH. Developments in control systems for rotary left ventricular assist devices for heart failure patients: a review. Physiol Meas 2012; 34:R1-27. [DOI: 10.1088/0967-3334/34/1/r1] [Citation(s) in RCA: 87] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
24
|
Granegger M, Moscato F, Casas F, Wieselthaler G, Schima H. Development of a pump flow estimator for rotary blood pumps to enhance monitoring of ventricular function. Artif Organs 2012; 36:691-9. [PMID: 22882439 DOI: 10.1111/j.1525-1594.2012.01503.x] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Estimation of instantaneous flow in rotary blood pumps (RBPs) is important for monitoring the interaction between heart and pump and eventually the ventricular function. Our group has reported an algorithm to derive ventricular contractility based on the maximum time derivative (dQ/dt(max) as a substitute for ventricular dP/dt(max) ) and pulsatility of measured flow signals. However, in RBPs used clinically, flow is estimated with a bandwidth too low to determine dQ/dt(max) in the case of improving heart function. The aim of this study was to develop a flow estimator for a centrifugal pump with bandwidth sufficient to provide noninvasive cardiac diagnostics. The new estimator is based on both static and dynamic properties of the brushless DC motor. An in vitro setup was employed to identify the performance of pump and motor up to 20 Hz. The algorithm was validated using physiological ventricular and arterial pressure waveforms in a mock loop which simulated different contractilities (dP/dt(max) 600 to 2300 mm Hg/s), pump speeds (2 to 4 krpm), and fluid viscosities (2 to 4 mPa·s). The mathematically estimated pump flow data were then compared to the datasets measured in the mock loop for different variable combinations (flow ranging from 2.5 to 7 L/min, pulsatility from 3.5 to 6 L/min, dQ/dt(max) from 15 to 60 L/min/s). Transfer function analysis showed that the developed algorithm could estimate the flow waveform with a bandwidth up to 15 Hz (±2 dB). The mean difference between the estimated and measured average flows was +0.06 ± 0.31 L/min and for the flow pulsatilities -0.27 ± 0.2 L/min. Detection of dQ/dt(max) was possible up to a dP/dt(max) level of 2300 mm Hg/s. In conclusion, a flow estimator with sufficient frequency bandwidth and accuracy to allow determination of changes in ventricular contractility even in the case of improving heart function was developed.
Collapse
Affiliation(s)
- Marcus Granegger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, Vienna, Austria.
| | | | | | | | | |
Collapse
|
25
|
Zhou MD, Yang C, Liu Z, Cysyk JP, Zheng SY. An implantable Fabry-Pérot pressure sensor fabricated on left ventricular assist device for heart failure. Biomed Microdevices 2012; 14:235-45. [PMID: 21997499 DOI: 10.1007/s10544-011-9601-z] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Continuous flow left ventricular assist devices (LVADs) are commonly used as bridge-to-transplantation or destination therapy for heart failure patients. However, non-optimal pumping speeds can reduce the efficacy of circulatory support or cause dangerous ventricular arrhythmias. Optimal flow control for continuous flow LVADs has not been defined and calls for an implantable pressure sensor integrated with the LVAD for real-time feedback control of pump speed based on ventricular pressure. A MEMS pressure sensor prototype is designed, fabricated and seamlessly integrated with LVAD to enable real-time control, optimize its performance and reduce its risks. The pressure sensing mechanism is based on Fabry-Pérot interferometer principle. A biocompatible parylene diaphragm with a silicon mirror at the center is fabricated directly on the inlet shell of the LVAD to sense pressure changes. The sensitivity, range and response time of the pressure sensor are measured and validated to meet the requirements of LVAD pressure sensing.
Collapse
Affiliation(s)
- Ming-Da Zhou
- Department of Bioengineering and Material Research Institute, Pennsylvania State University, University Park, PA 16802, USA
| | | | | | | | | |
Collapse
|
26
|
KARANTONIS DEANM, CLOHERTY SHAUNL, LOVELL NIGELH, MASON DAVIDG, SALAMONSEN ROBERTF, AYRE PETERJ. NONINVASIVE DETECTION OF SUCTION IN AN IMPLANTABLE ROTARY BLOOD PUMP USING NEURAL NETWORKS. INTERNATIONAL JOURNAL OF COMPUTATIONAL INTELLIGENCE AND APPLICATIONS 2011. [DOI: 10.1142/s1469026808002302] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Granting those heart failure patients who are recipients of an implantable rotary blood pump (iRBP) greater functionality in daily activities is a key long-term strategy currently being pursued by many research groups. A reliable technique for noninvasive detection of the various pumping states, most notably that of ventricular collapse or suction, is an essential component of this strategy. Presented in this study is such a technique, whereby various indicators are derived from the noninvasive pump feedback signals, and a suitable computational methodology developed to classify the pumping states of interest. Clinical telemetry data from ten implant recipients was categorized (with the aid of trans-oesophageal echocardiography) into the normal and suction states. These data are used to develop a pumping state classifier based on an artificial neural network (ANN). Nine indices, derived from the noninvasive impeller speed signal, form the inputs to this ANN classifier. During validation, the resulting ANN classifier achieved a maximum sensitivity of 98.54% (609/618 samples of 5 s in length) and specificity of 99.26% (12,123/12,213 samples) for correct detection of the suction state. The ability to detect the suction state with such a high degree of accuracy provides a critical parameter both for control strategy development, and for clinical care of the implant recipient.
Collapse
Affiliation(s)
- DEAN M. KARANTONIS
- School of Electrical Engineering and Telecommunications, University of New South Wales, Sydney NSW 2052, Australia
| | - SHAUN L. CLOHERTY
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney NSW 2052, Australia
| | - NIGEL H. LOVELL
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney NSW 2052, Australia
| | - DAVID G. MASON
- Department of Surgery, Monash University, Melbourne VIC, Australia
| | | | - PETER J. AYRE
- Ventracor Limited, Chatswood, Sydney NSW 2067, Australia
| |
Collapse
|
27
|
Gaddum NR, Timms DL, Stevens M, Mason D, Lovell N, Fraser JF. Comparison of preload-sensitive pressure and flow controller strategies for a dual device biventricular support system. Artif Organs 2011; 36:256-65. [PMID: 21955295 DOI: 10.1111/j.1525-1594.2011.01344.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The use of rotary left ventricular assist devices (LVADs) has extended to destination and recovery therapy for end-stage heart failure. Incidence of right ventricular failure while on LVAD support requires a second device be implanted to support the failing right ventricle. Without a commercially available implantable rotary right ventricular assist device, rotary LVADs are cannulated into the right heart and operation modified to provide suitable support for the pulmonary system. While this approach can alleviate the demand for transplant through long-term biventricular support, it uncovers a new challenge with respect to controller strategies for these dual device support systems. This study compares the preload sensitivity of rotary, dual device biventricular assistance controllers in light of their ability to adjust the flow rate according to physiological demand. A Frank-Starling-like flow controller which requires both inlet pressure and flow sensors is compared to pressure controllers which maintain atrial or inlet cannula pressures through the use of a single pressure sensor. It was found that cannula selection and the location of a pressure controller's single pressure sensor can be tailored to adjust the preload sensitivity. When located within the atria, this sensitivity is effectively infinite. Moving the sensor to the base of a 450-mm cannula, however, decreased the sensitivity to 0.22 (L/min)/mm Hg. This indicates the potential for simple and reliable VAD controllers with increased preload sensitivity without the need for complex controllers requiring an array of hemodynamic sensors.
Collapse
Affiliation(s)
- Nicholas Richard Gaddum
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW, Australia.
| | | | | | | | | | | |
Collapse
|
28
|
Gao B, Gu K, Zeng Y, Chang Y. An anti-suction control for an intra-aorta pump using blood assistant index: a numerical simulation. Artif Organs 2011; 36:275-82. [PMID: 21951205 DOI: 10.1111/j.1525-1594.2011.01309.x] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
With the extensive use of the left ventricular assist device (LVAD) as a treatment of heart failure, suction detection has become a key issue that directly affects the treatment. To detect the phenomenon of suction, a blood assistant index (BAI) is defined, which reflects the unloading level of the pump. The BAI is a ratio of the external work of LVAD and the input power of cardiovascular system. Using the theory of model-free adaptive control algorithm, an anti-suction controller, which chooses the heart rate and BAI as control variables, is designed. As a key feature, the proposed control algorithm adjusts the pump speed according to not only the blood demand of circulatory system but also the function of the native heart. Subsequently, the performance and robustness of the controller are evaluated using a numerical simulation of the assisted circulation and an in vitro experiment. The simulation and experimental results demonstrate that the BAI detects the suction occur accurately, and the controller can maintain the heart rate and BAI tracking the reference values with a response time of less than 6 s.
Collapse
Affiliation(s)
- Bin Gao
- School of Life Science and BioEngineering, Beijing University of Technology, Beijing, China
| | | | | | | |
Collapse
|
29
|
Abstract
Left ventricular assist device (LVAD) support is an accepted treatment of patients with end-stage heart failure. The increased applicability and excellent results with LVADs have revolutionized the treatment options available for such patients. Success with LVADs as bridge-to-transplant therapy has led to their successful use as an alternate to a transplant (ie, as destination therapy [DT]). The use of these devices as DT represents a relatively newer but growing indication. Until recently, most patients who have undergone LVAD implantation have been supported by pulsatile devices. Newer continuous-flow (CF) pumps have resulted in superior outcomes, including significantly reduced complication rates with improved durability over first-generation pulsatile design pumps. However, as with all new technology, the newer LVADs have introduced management challenges that were either unimportant or absent with pulsatile LVADs. This article reviews the current state of left ventricular devices, focusing on the CF pumps that currently dominate the field, including clinical outcomes, the physiologic and pathologic effects that are associated with CF pumps, and their unique management issues and complications.
Collapse
Affiliation(s)
- Marco Caccamo
- Department of Medicine, Division of Cardiovascular Medicine, University of Minnesota, Minneapolis, MN, USA
| | | | | |
Collapse
|
30
|
Arndt A, Nüsser P, Lampe B. Fully Autonomous Preload-Sensitive Control of Implantable Rotary Blood Pumps. Artif Organs 2010; 34:726-35. [DOI: 10.1111/j.1525-1594.2010.01092.x] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
31
|
Moscato F, Arabia M, Colacino FM, Naiyanetr P, Danieli GA, Schima H. Left Ventricle Afterload Impedance Control by an Axial Flow Ventricular Assist Device: A Potential Tool for Ventricular Recovery. Artif Organs 2010; 34:736-44. [DOI: 10.1111/j.1525-1594.2010.01066.x] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
32
|
Saeed D, Massiello AL, Shalli S, Fumoto H, Horai T, Anzai T, Golding LAR, Fukamachi K. Introduction of fixed-flow mode in the DexAide right ventricular assist device. J Heart Lung Transplant 2010; 29:32-6. [PMID: 20123244 DOI: 10.1016/j.healun.2009.09.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2009] [Revised: 09/04/2009] [Accepted: 09/09/2009] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Although some continuous-flow left ventricular assist device algorithms have been created to respond to varying patient physiology, very little research has been conducted on control of right ventricular support in uni- or biventricular application. The purpose of this study was to develop and evaluate a simple and reliable fixed-flow algorithm for the DexAide right ventricular assist device (RVAD). This algorithm automatically adjusts speed to maintain a target flow while preventing ventricular suction when a requested target flow exceeds available tricuspid flow. METHODS Fixed-flow control mode was evaluated in 17 DexAide RVAD long-term bovine studies, with a duration ranging from 14 to 90 days (33 +/- 24 days). Targeted fixed-flow levels ranged from 4.0 to 6.5 liters/min. Data were monitored on an hourly basis. Pump-flow data were also recorded on a weekly basis to document the speed increment required to increase pump flow from 5 to 8 liters/min at 0.5-liter/min increments. RESULTS The fixed-flow control mode was evaluated for a total duration of 5,283 hours without complications related to pump flow or left/right circulation imbalance. The pump speed varied between 2,000 and 3,220 rpm to maintain the flow constant at each target level. The average absolute mismatch between the target flow and measured flow was 0.6 +/- 0.5 liter/min. CONCLUSIONS Fixed-flow control mode with a pre-determined maximum automatic pump speed can be used safely and effectively in the DexAide RVAD. It can provide target flows by adjusting the pump speed while monitoring pump-flow response to automatic speed increment requests.
Collapse
Affiliation(s)
- Diyar Saeed
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio 44195, USA
| | | | | | | | | | | | | | | |
Collapse
|
33
|
Physiologic and pathologic changes in patients with continuous-flow ventricular assist devices. J Cardiovasc Transl Res 2009; 2:154-8. [PMID: 20559982 DOI: 10.1007/s12265-009-9092-y] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2009] [Accepted: 02/12/2009] [Indexed: 01/28/2023]
Abstract
The clinical use of the newer continuous-flow pumps for mechanical circulatory support have resulted in superior outcomes including significantly reduced complication rates with improved durability over first generation pulsatile design pumps. However, as with all new technology, the newer LVADs have introduced a different set of management issues, as well as a unique risk profile into the mechanical circulatory support arena that were previously absent or unimportant with pulsatile LVADs. These include the effects of continuous flow on the systemic circulation and end-organ function, risk of thromboembolism, and pump thrombosis related to contact bearings in the blood path, the possible increased incidence of gastrointestinal bleeding, and ventricular arrhythmias, as well as alterations in the unloading characteristics of continuous-flow devices. This manuscript overviews the physiologic and pathologic effects that are associated with continuous-flow pumps and their unique management issues and complications.
Collapse
|
34
|
Arndt A, Nüsser P, Graichen K, Müller J, Lampe B. Physiological control of a rotary blood pump with selectable therapeutic options: control of pulsatility gradient. Artif Organs 2008; 32:761-71. [PMID: 18959664 DOI: 10.1111/j.1525-1594.2008.00628.x] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A control strategy for rotary blood pumps meeting different user-selectable control objectives is proposed: maximum support with the highest feasible flow rate versus medium support with maximum ventricular washout and controlled opening of the aortic valve (AoV). A pulsatility index (PI) is calculated from the pressure difference, which is deduced from the axial thrust measured by the magnetic bearing of the pump. The gradient of PI with respect to pump speed (GPI) is estimated via online system identification. The outer loop of a cascaded controller regulates GPI to a reference value satisfying the selected control objective. The inner loop controls the PI to a reference value set by the outer loop. Adverse pumping states such as suction and regurgitation can be detected on the basis of the GPI estimates and corrected by the controller. A lumped-parameter computer model of the assisted circulation was used to simulate variations of ventricular contractility, pulmonary venous pressure, and aortic pressure. The performance of the outer control loop was demonstrated by transitions between the two control modes. Fast reaction of the inner loop was tested by stepwise reduction of venous return. For maximum support, a low PI was maintained without inducing ventricular collapse. For maximum washout, the pump worked at a high PI in the transition region between the opening and the permanently closed AoV. The cascaded control of GPI and PI is able to meet different control objectives and is worth testing in vitro and in vivo.
Collapse
|
35
|
Abstract
All rotary blood pumps (RBPs) are prone to the harmful effects of ventricular collapse or "suction events" because of over-pumping, because they are inherently preload insensitive devices, yet RBP controllers do not comprise a clinically reliable suction detector. We therefore investigated the clinical performance of seven expertly selected time domain indices of suction based on the observed positive spike induced in the RBP impeller speed waveform. Using expert panel classifications, a balanced set of 404 five-second speed snapshots of normal and suction events was created from the impeller speed 25 Hz data in 12 VentrAssist implant patients. Initially, suction index threshold levels were set differently for each patient, giving best sensitivity 95% and specificity 99%. However, analysis of paired combinations of suction indices with fixed thresholds identified one pair giving an acceptable sensitivity of 99.5% and specificity 97.5%; the low number of high speed data samples relative to the speed snapshot mean and maximum OR the largest increase in successive speed maxima. The additional precondition of RBP speed amplitude exceeding a low threshold level allows its more general application to patients with low cardiac contractility. This gives a suction detector with high clinical utility; requiring three index threshold settings only.
Collapse
|
36
|
John R. Current Axial-Flow Devices—the HeartMate II and Jarvik 2000 Left Ventricular Assist Devices. Semin Thorac Cardiovasc Surg 2008; 20:264-72. [DOI: 10.1053/j.semtcvs.2008.08.001] [Citation(s) in RCA: 81] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/21/2008] [Indexed: 11/11/2022]
|
37
|
Karantonis DM, Mason DG, Salamonsen RF, Ayre PJ, Cloherty SL, Lovell NH. Classification of Physiologically Significant Pumping States in an Implantable Rotary Blood Pump: Patient Trial Results. ASAIO J 2007; 53:617-22. [PMID: 17885336 DOI: 10.1097/mat.0b013e318147e6a9] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
An integral component in the development of a control strategy for implantable rotary blood pumps is the task of reliably detecting the occurrence of left ventricular collapse due to overpumping of the native heart. Using the noninvasive pump feedback signal of impeller speed, an approach to distinguish between overpumping (or ventricular collapse) and the normal pumping state has been developed. Noninvasive pump signals from 10 human pump recipients were collected, and the pumping state was categorized as either normal or suction, based on expert opinion aided by transesophageal echocardiographic images. A number of indices derived from the pump speed waveform were incorporated into a classification and regression tree model, which acted as the pumping state classifier. When validating the model on 12,990 segments of unseen data, this methodology yielded a peak sensitivity/specificity for detecting suction of 99.11%/98.76%. After performing a 10-fold cross-validation on all of the available data, a minimum estimated error of 0.53% was achieved. The results presented suggest that techniques for pumping state detection, previously investigated in preliminary in vivo studies, are applicable and sufficient for use in the clinical environment.
Collapse
Affiliation(s)
- Dean M Karantonis
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW, Australia
| | | | | | | | | | | |
Collapse
|
38
|
Korakianitis T, Shi Y. Numerical Comparison of Hemodynamics With Atrium to Aorta and Ventricular Apex to Aorta VAD Support. ASAIO J 2007; 53:537-48. [PMID: 17885325 DOI: 10.1097/mat.0b013e318142bfce] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
We report the first attempt to study with numerical methods ventricular assist device (VAD) models and the effects of various inlet VAD cannulations, coupling physical explanations and numerical investigation conclusions with clinical research results. We compared the hemodynamic response with VAD support by using two distinct VAD-inlet cannulation configurations: left atrium to aorta and left ventricular apex to aorta. Impeller pump and displacement pump VADs are considered. Constant VAD flow rate and counterpulsation motion models are simulated. The native cardiovascular system is modeled using the concentrated-parameter method by considering the flow resistance, vessel elasticity, and inertial effect of blood flow in cardiovascular system individual segments. Impeller and displacement pump dynamic models are represented by corresponding inlet and outlet flow rate changes in the VADs. Results show that the two VAD inlet cannulation configurations produce similar cardiac response (flows, pressures, volumes), except that when the VAD flow approaches the 100% assisting condition, the peak left ventricular systolic pressure and diastolic volume increase slightly in the left atrial cannulation, whereas they drop markedly in the left ventricular apex cannulation, suggesting increased ventricular wall tension and ventricular dilatation in the left atrial cannulation and that hemodynamically the left ventricular apex cannulation is more advantageous.
Collapse
|
39
|
Vollkron M, Voitl P, Ta J, Wieselthaler G, Schima H. Suction Events During Left Ventricular Support and Ventricular Arrhythmias. J Heart Lung Transplant 2007; 26:819-25. [DOI: 10.1016/j.healun.2007.05.011] [Citation(s) in RCA: 121] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2006] [Revised: 03/16/2007] [Accepted: 05/17/2007] [Indexed: 11/15/2022] Open
|
40
|
Malchesky PS. Artificial Organs 2006: a year in review. Artif Organs 2007; 31:225-41. [PMID: 17343699 DOI: 10.1111/j.1525-1594.2007.00370.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]