• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4617544)   Today's Articles (177)   Subscriber (49400)
For: Lee H, Homma A, Taenaka Y. Hydrodynamic Characteristics of Bileaflet Mechanical Heart Valves in an Artificial Heart: Cavitation and Closing Velocity. Artif Organs 2007;31:532-7. [PMID: 17584477 DOI: 10.1111/j.1525-1594.2007.00419.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Number Cited by Other Article(s)
1
Qian JY, Gao ZX, Li WQ, Jin ZJ. Cavitation Suppression of Bileaflet Mechanical Heart Valves. Cardiovasc Eng Technol 2020;11:783-794. [PMID: 32918244 DOI: 10.1007/s13239-020-00484-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Accepted: 09/02/2020] [Indexed: 10/23/2022]
2
Transient Study of Flow and Cavitation Inside a Bileaflet Mechanical Heart Valve. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10072548] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
3
Sadipour M, Hanafizadeh P, Sadeghy K, Sattari A. Effect of Aortic Wall Deformation with Healthy and Calcified Annulus on Hemodynamic Performance of Implanted On-X Valve. Cardiovasc Eng Technol 2020;11:141-161. [PMID: 31912432 DOI: 10.1007/s13239-019-00453-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Accepted: 12/24/2019] [Indexed: 11/27/2022]
4
Wium E, Jordaan CJ, Botes L, Smit FE. Alternative mechanical heart valves for the developing world. Asian Cardiovasc Thorac Ann 2019;28:431-443. [PMID: 31752500 DOI: 10.1177/0218492319891255] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
5
Qian JY, Gao ZX, Hou CW, Jin ZJ. A comprehensive review of cavitation in valves: mechanical heart valves and control valves. Biodes Manuf 2019. [DOI: 10.1007/s42242-019-00040-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
6
Schubert K, Schaller T, Stojenthin E, Stephan C, Sievers HH, Scharfschwerdt M. A novel trileaflet mechanical heart valve: first in vitro results. Interact Cardiovasc Thorac Surg 2018;28:689-694. [DOI: 10.1093/icvts/ivy337] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2018] [Revised: 10/24/2018] [Accepted: 10/29/2018] [Indexed: 11/12/2022]  Open
7
Mohammadi H, Mequanint K. Prosthetic aortic heart valves: modeling and design. Med Eng Phys 2010;33:131-47. [PMID: 20971672 DOI: 10.1016/j.medengphy.2010.09.017] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2010] [Revised: 07/19/2010] [Accepted: 09/24/2010] [Indexed: 10/18/2022]
8
Experimental Study on the Reynolds and Viscous Shear Stress of Bileaflet Mechanical Heart Valves in a Pneumatic Ventricular Assist Device. ASAIO J 2009;55:348-54. [DOI: 10.1097/mat.0b013e3181a793e0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
9
Lee H, Akagawa E, Tatsumi E, Taenaka Y. Characteristics of cavitation intensity in a mechanical heart valve using a pulsatile device: synchronized analysis between visual images and pressure signals. J Artif Organs 2008;11:60-6. [DOI: 10.1007/s10047-008-0408-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2007] [Accepted: 02/23/2008] [Indexed: 10/21/2022]
10
Malchesky PS. Artificial Organs 2007: A Year in Review. Artif Organs 2008. [DOI: 10.1111/j.1525-1594.2007.00536.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA