Schiavone NK, Elkins CJ, McElhinney DB, Eaton JK, Marsden AL. In Vitro Assessment of Right Ventricular Outflow Tract Anatomy and Valve Orientation Effects on Bioprosthetic Pulmonary Valve Hemodynamics. Cardiovasc Eng Technol 2021; 12:215-231. [PMID: 33452649 DOI: 10.1007/s13239-020-00507-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Accepted: 12/02/2020] [Indexed: 01/30/2023]
Abstract
PURPOSE The congenital heart defect Tetralogy of Fallot (ToF) affects 1 in 2500 newborns annually in the US and typically requires surgical repair of the right ventricular outflow tract (RVOT) early in life, with variations in surgical technique leading to large disparities in RVOT anatomy among patients. Subsequently, often in adolescence or early adulthood, patients usually require surgical placement of a xenograft or allograft pulmonary valve prosthesis. Valve longevity is highly variable for reasons that remain poorly understood. METHODS This work aims to assess the performance of bioprosthetic pulmonary valves in vitro using two 3D printed geometries: an idealized case based on healthy subjects aged 11 to 13 years and a diseased case with a 150% dilation in vessel diameter downstream of the valve. Each geometry was studied with two valve orientations: one with a valve leaflet opening posterior, which is the native pulmonary valve position, and one with a valve leaflet opening anterior. RESULTS Full three-dimensional, three-component, phase-averaged velocity fields were obtained in the physiological models using 4D flow MRI. Flow features, particularly vortex formation and reversed flow regions, differed significantly between the RVOT geometries and valve orientations. Pronounced asymmetry in streamwise velocity was present in all cases, while the diseased geometry produced additional asymmetry in radial flows. Quantitative integral metrics demonstrated increased secondary flow strength and recirculation in the rotated orientation for the diseased geometry. CONCLUSIONS The compound effects of geometry and orientation on bioprosthetic valve hemodynamics illustrated in this study could have a crucial impact on long-term valve performance.
Collapse
Affiliation(s)
| | | | | | - John K Eaton
- Mechanical Engineering, Stanford University, Stanford, CA, USA
| | - Alison L Marsden
- Pediatrics and Bioengineering, Stanford University, Stanford, CA, USA.
| |
Collapse
|
2
|
Abstract
Currently, clinicians are seeking new, minimally invasive treatment options for functional tricuspid regurgitation (FTR). Challenging tricuspid complexity requires the evaluation of the treatment techniques in adequate and realistic preclinical scenario. The purpose of this article is to describe the design and functional assessment of a novel passive beating heart model of the pulmonary circulation with the possibility to tightly control FTR. The model housed porcine hearts actuated by a volumetric pump that cyclically pressurized the right ventricle. The in-vitro FTR model exploited the tendency of the ventricle to dilate under pressure. The dilation entailed papillary muscles displacement and valve annulus enlargement, thus inducing tricuspid valve insufficiency. Employment of constraint bands allowed to restore valve competency. The system provided consistent replication of the main determinants of the pulmonary hemodynamics in a wide range of working conditions. The experimental model of FTR was reliable, easily controllable, and showed good stability-over-time. Echocardiography and fiberscope imaging provided a unique opportunity to investigate valve dynamics. These features make the platform suitable for realistic training purposes and testing of the upcoming FTR therapies.
Collapse
|
3
|
Knoops PGM, Biglino G, Hughes AD, Parker KH, Xu L, Schievano S, Torii R. A Mock Circulatory System Incorporating a Compliant 3D-Printed Anatomical Model to Investigate Pulmonary Hemodynamics. Artif Organs 2017; 41:637-646. [PMID: 27925228 PMCID: PMC5384635 DOI: 10.1111/aor.12809] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2016] [Revised: 06/22/2016] [Accepted: 06/27/2016] [Indexed: 11/29/2022]
Abstract
A realistic mock circulatory system (MCS) could be a valuable in vitro testbed to study human circulatory hemodynamics. The objective of this study was to design a MCS replicating the pulmonary arterial circulation, incorporating an anatomically representative arterial model suitable for testing clinically relevant scenarios. A second objective of the study was to ensure the system's compatibility with magnetic resonance imaging (MRI) for additional measurements. A latex pulmonary arterial model with two generations of bifurcations was manufactured starting from a 3D-printed mold reconstructed from patient data. The model was incorporated into a MCS for in vitro hydrodynamic measurements. The setup was tested under physiological pulsatile flow conditions and results were evaluated using wave intensity analysis (WIA) to investigate waves traveling in the arterial system. Increased pulmonary vascular resistance (IPVR) was simulated as an example of one pathological scenario. Flow split between right and left pulmonary artery was found to be realistic (54 and 46%, respectively). No substantial difference in pressure waveform was observed throughout the various generations of bifurcations. Based on WIA, three main waves were identified in the main pulmonary artery (MPA), that is, forward compression wave, backward compression wave, and forward expansion wave. For IPVR, a rise in mean pressure was recorded in the MPA, within the clinical range of pulmonary arterial hypertension. The feasibility of using the MCS in the MRI scanner was demonstrated with the MCS running 2 h consecutively while acquiring preliminary MRI data. This study shows the development and verification of a pulmonary MCS, including an anatomically correct, compliant latex phantom. The setup can be useful to explore a wide range of hemodynamic questions, including the development of patient- and pathology-specific models, considering the ease and low cost of producing rapid prototyping molds, and the versatility of the setup for invasive and noninvasive (i.e., MRI) measurements.
Collapse
Affiliation(s)
- Paul G M Knoops
- UCL Institute of Child Health, London, United Kingdom
- Great Ormond Street Hospital for Children, NHS Trust, London, United Kingdom
- Department of Mechanical Engineering, University College London, London, United Kingdom
| | - Giovanni Biglino
- Great Ormond Street Hospital for Children, NHS Trust, London, United Kingdom
- Bristol Heart Institute, School of Clinical Sciences, University of Bristol, Bristol, United Kingdom
| | - Alun D Hughes
- UCL Institute of Cardiovascular Science, London, United Kingdom
| | - Kim H Parker
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Linzhang Xu
- Department of Mechanical Engineering, University College London, London, United Kingdom
| | - Silvia Schievano
- UCL Institute of Child Health, London, United Kingdom
- UCL Institute of Cardiovascular Science, London, United Kingdom
| | - Ryo Torii
- Department of Mechanical Engineering, University College London, London, United Kingdom
| |
Collapse
|
4
|
Piola M, Vismara R, Tasca G, Lucherini F, Redaelli P, Soncini M, Romagnoni C, Mangini A, Antona C, Fiore GB. Design of a simple coronary impedance simulator for thein vitrostudy of the complex coronary hemodynamics. Physiol Meas 2016; 37:2274-2285. [DOI: 10.1088/1361-6579/37/12/2274] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
5
|
Vismara R, Gelpi G, Prabhu S, Romitelli P, Troxler LG, Mangini A, Romagnoni C, Contino M, Van Hoven DT, Lucherini F, Jaworek M, Redaelli A, Fiore GB, Antona C. Transcatheter Edge-to-Edge Treatment of Functional Tricuspid Regurgitation in an Ex Vivo Pulsatile Heart Model. J Am Coll Cardiol 2016; 68:1024-33. [DOI: 10.1016/j.jacc.2016.06.022] [Citation(s) in RCA: 65] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2016] [Revised: 06/14/2016] [Accepted: 06/16/2016] [Indexed: 11/26/2022]
|
6
|
Biglino G, Verschueren P, Zegels R, Taylor AM, Schievano S. Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing. J Cardiovasc Magn Reson 2013; 15:2. [PMID: 23324211 PMCID: PMC3564729 DOI: 10.1186/1532-429x-15-2] [Citation(s) in RCA: 113] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2012] [Accepted: 12/17/2012] [Indexed: 01/17/2023] Open
Abstract
BACKGROUND Compliant vascular phantoms are desirable for in-vitro patient-specific experiments and device testing. TangoPlus FullCure 930 is a commercially available rubber-like material that can be used for PolyJet rapid prototyping. This work aims to gather preliminary data on the distensibility of this material, in order to assess the feasibility of its use in the context of experimental cardiovascular modelling. METHODS The descending aorta anatomy of a volunteer was modelled in 3D from cardiovascular magnetic resonance (CMR) images and rapid prototyped using TangoPlus. The model was printed with a range of increasing wall thicknesses (0.6, 0.7, 0.8, 1.0 and 1.5 mm), keeping the lumen of the vessel constant. Models were also printed in both vertical and horizontal orientations, thus resulting in a total of ten specimens. Compliance tests were performed by monitoring pressure variations while gradually increasing and decreasing internal volume. Knowledge of distensibility was thus derived and then implemented with CMR data to test two applications. Firstly, a patient-specific compliant model of hypoplastic aorta suitable for connection in a mock circulatory loop for in-vitro tests was manufactured. Secondly, the right ventricular outflow tract (RVOT) of a patient necessitating pulmonary valve replacement was printed in order to physically test device insertion and assess patient's suitability for percutaneous pulmonary valve intervention. RESULTS The distensibility of the material was identified in a range from 6.5 × 10(-3) mmHg(-1) for the 0.6 mm case, to 3.0 × 10(-3) mmHg(-1) for the 1.5 mm case. The models printed in the vertical orientation were always more compliant than their horizontal counterpart. Rapid prototyping of a compliant hypoplastic aorta and of a RVOT anatomical model were both feasible. Device insertion in the RVOT model was successful. CONCLUSION Values of distensibility, compared with literature data, show that TangoPlus is suitable for manufacturing arterial phantoms, with the added benefit of being compatible with PolyJet printing, thus guaranteeing representative anatomical finishing, and quick and inexpensive fabrication. The appealing possibility of printing models of non-uniform wall thickness, resembling more closely certain physiological scenarios, can also be explored. However, this material appears to be too stiff for modelling the more compliant systemic venous system.
Collapse
MESH Headings
- Adult
- Aorta, Thoracic/abnormalities
- Aorta, Thoracic/pathology
- Aorta, Thoracic/physiopathology
- Arterial Pressure
- Blood Vessel Prosthesis
- Blood Vessel Prosthesis Implantation/instrumentation
- Compliance
- Computer-Aided Design
- Feasibility Studies
- Heart Defects, Congenital/pathology
- Heart Defects, Congenital/physiopathology
- Heart Defects, Congenital/therapy
- Humans
- Image Processing, Computer-Assisted
- Imaging, Three-Dimensional
- Infant
- Magnetic Resonance Imaging/instrumentation
- Materials Testing
- Models, Anatomic
- Phantoms, Imaging
- Prosthesis Design
Collapse
Affiliation(s)
- Giovanni Biglino
- Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science & Great Ormond Street Hospital for Children, NHS Trust, London, UK
| | - Peter Verschueren
- Materialise NV, Biomedical Engineering Business Unit, Leuven, Belgium
| | - Raf Zegels
- Materialise NV, Biomedical Engineering Business Unit, Leuven, Belgium
| | - Andrew M Taylor
- Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science & Great Ormond Street Hospital for Children, NHS Trust, London, UK
| | - Silvia Schievano
- Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science & Great Ormond Street Hospital for Children, NHS Trust, London, UK
| |
Collapse
|
7
|
Biglino G, Capelli C, Binazzi A, Reggiani R, Cosentino D, Migliavacca F, Bonhoeffer P, Taylor AM, Schievano S. Virtual and real bench testing of a new percutaneous valve device: a case study. EUROINTERVENTION 2012; 8:120-8. [PMID: 22580256 DOI: 10.4244/eijv8i1a19] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
AIMS To validate patient-specific computational testing of a second-generation device for percutaneous pulmonary valve implantation (PPVI), against realistic in vitro data. METHODS AND RESULTS Tests were initially carried out in a simple loading mode, performing a compliance test on a rapid prototyped cylinder. This model was reproduced computationally and validated against the experimental data. A second-generation PPVI stent-graft, with no valve mounted, was then deployed in a simplified cylindrical geometry, measuring its displacement when subjected to a pressure pulse. Experimental and computational measurements were in good agreement. Finally, having selected a patient regarded as unsuitable for first-generation PPVI, but potentially suitable for a second-generation device, the stent-graft was studied in the rapidly prototyped patient-specific right ventricular outflow tract (RVOT). Stent positioning and radial displacements with pulsatile flow were observed in a mock circuit using fluoroscopy imaging. Stent deformation and anchoring were measured both in vitro and computationally. Both tests indicated that the stent was well anchored in the RVOT, especially in the distal position, and its central region was rounded, ensuring, were a valve present, optimal valve function. CONCLUSION We suggest that an experimentally validated computational model can be used for preclinical device characterisation and patient selection.
Collapse
Affiliation(s)
- Giovanni Biglino
- Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science and Great Ormond Street Hospital for Children, London, United Kingdom
| | | | | | | | | | | | | | | | | |
Collapse
|
8
|
In Vitro Study of Aortic Valves Treated with Neo-Chordae Grafts: Hydrodynamics and Tensile Force Measurements. Ann Biomed Eng 2011; 39:1024-31. [DOI: 10.1007/s10439-010-0235-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2010] [Accepted: 12/18/2010] [Indexed: 11/25/2022]
|
9
|
|
10
|
A Novel Approach to the In Vitro Hydrodynamic Study of the Aortic Valve: Mock Loop Development and Test. ASAIO J 2010; 56:279-84. [DOI: 10.1097/mat.0b013e3181d9c295] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
11
|
Lanzarone E, Vismara R, Fiore GB. A New Pulsatile Volumetric Device With Biomorphic Valves for the In Vitro Study of the Cardiovascular System. Artif Organs 2009; 33:1048-62. [DOI: 10.1111/j.1525-1594.2009.00812.x] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|