1
|
Mekled S, Elwazeer S, Jurado CA, White J, Faddoul F, Afrashtehfar KI, Fischer NG. Ultra-Translucent Zirconia Laminate Veneers: The Influence of Restoration Thickness and Stump Tooth-Shade. MATERIALS (BASEL, SWITZERLAND) 2023; 16:3030. [PMID: 37109865 PMCID: PMC10145317 DOI: 10.3390/ma16083030] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/19/2023] [Revised: 03/30/2023] [Accepted: 04/08/2023] [Indexed: 06/19/2023]
Abstract
This in vitro study aimed to evaluate the final shade of translucent zirconia laminate veneers with varying thicknesses over teeth with different shades. Seventy-five chairside computer-aided design/computer-aided manufacturing (CAD/CAM) shade A1 third-generation zirconia dental veneers, with thicknesses of 0.50 mm, 0.75 mm, and 1.00 mm, were placed on resin composite teeth with shades ranging from A1 to A4. The laminate veneers were divided into groups based on thickness and background shade. All restorations were evaluated with a color imaging spectrophotometer, to map the veneer surface from A1 to D4. Regardless of the thickness or background shade, all dental veneers showed color alteration from the original shade. Veneers with 0.5 mm thickness tended to display the B1 shade, while veneers with 0.75 mm and 1.0 mm thickness primarily exhibited the B2 shade. The thickness of the laminate veneer and background shade significantly modified the original shade of the zirconia veneer. One-way analysis of variance was performed and a Kruskal-Wallis test was used to determine the significance between the three veneer thicknesses groups. The results indicated that the thinner restorations showed higher values with the color imaging spectrophotometer, suggesting that thinner veneers may result in more consistent color matching. This study underscores the importance of carefully considering thickness and background shade when selecting zirconia laminate veneers, to ensure optimal color matching and overall aesthetic outcomes.
Collapse
Affiliation(s)
- Salwa Mekled
- Temple University Kornberg School of Dentistry, Philadelphia, PA 19140, USA
| | - Salma Elwazeer
- Texas Tech University Health Sciences Center El Paso Woody L. Hunt School of Dental Medicine, El Paso, TX 79905, USA
| | - Carlos A. Jurado
- The University of Iowa College of Dentistry and Dental Clinics, Iowa City, IA 52242, USA
| | - James White
- Texas Tech University Health Sciences Center El Paso Woody L. Hunt School of Dental Medicine, El Paso, TX 79905, USA
| | - Faddy Faddoul
- Texas Tech University Health Sciences Center El Paso Woody L. Hunt School of Dental Medicine, El Paso, TX 79905, USA
| | - Kelvin I. Afrashtehfar
- Evidence-Based Practice Unit, Clinical Sciences Department, Ajman College of Dentistry, Ajman City P.O. Box 346, AE, United Arab Emirates
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, BE, Switzerland
- Artificial Intelligence Research Center (AIRC), Ajman City P.O. Box 346, AE, United Arab Emirates
| | - Nicholas G. Fischer
- Minnesota Dental Research Center for Biomaterials and Biomechanics, University of Minnesota School of Dentistry, Minneapolis, MN 55455, USA
| |
Collapse
|
2
|
Okutan Y, Kandemir B, Donmez MB, Yucel MT. Effect of the thickness of CAD-CAM materials on the shear bond strength of light-polymerized resin cement. Eur J Oral Sci 2022; 130:e12892. [PMID: 35969188 DOI: 10.1111/eos.12892] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 07/19/2022] [Indexed: 11/29/2022]
Abstract
This study aimed to investigate the effect of the thickness of computer aided design-computer aided manufacturing (CAD-CAM) restorative materials on the bond strength of light-polymerized resin cement. Ninety specimens were prepared from three different CAD-CAM materials (a leucite-based glass-ceramic [Empress CAD], a polymer-infiltrated ceramic network [Vita Enamic], and a zirconia-reinforced lithium silicate glass-ceramic [Vita Suprinity]) in different thicknesses (1, 2, and 3 mm). One surface of each specimen was treated by using a single-step self-etching ceramic primer (Monobond Etch & Prime). Light-polymerized resin cement was bonded to treated surfaces by exposure to a light-emitting diode curing unit from the untreated side of the samples. Shear bond strength (SBS) between the ceramic and the resin cement was measured by using a universal testing machine. The leucite-based glass-ceramic had higher SBS values than the other materials at each thickness. For each material, 1 mm-thick specimens had the highest SBS values. The difference between the SBS values of 2 mm- and 3 mm-thick polymer-infiltrated ceramic network was nonsignificant, whereas the SBS values of 2 mm-thick leucite-based glass-ceramic and the zirconia-reinforced lithium silicate glass-ceramic were significantly higher than those of the corresponding 3 mm-thick specimens. The choice of the material and its thickness may be highly important for clinical success when light-polymerized resin cements are used for cementation.
Collapse
Affiliation(s)
- Yener Okutan
- Department of Prosthodontics, Faculty of Dentistry, Aydin Adnan Menderes University, Aydin, Turkey
| | - Banucicek Kandemir
- Department of Prosthodontics, Faculty of Dentistry, Selcuk University, Konya, Turkey
| | - Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey.,Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Munir Tolga Yucel
- Department of Prosthodontics, Faculty of Dentistry, Selcuk University, Konya, Turkey
| |
Collapse
|
3
|
The influence of zirconia veneer thickness on the degree of conversion of resin-matrix cements: an integrative review. Clin Oral Investig 2021; 25:3395-3408. [PMID: 33783593 DOI: 10.1007/s00784-021-03904-w] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 03/19/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVE The main aim of this study was to conduct an integrative review on the influence of the zirconia veneer thickness on the degree of conversion of resin-matrix cements. MATERIALS AND METHOD An electronic search was performed on PubMed using a combination of the following search items: zirconia, thickness, veneer, degree of conversion, resin cement, light curing, and polymerization. Articles published in the English language, up to July 2020, were included regarding the influence of ceramic veneer thickness on the degree of conversion of resin-matrix cements. Randomized controlled trials and prospective cohort studies were also evaluated. RESULTS Of the 21 selected studies, 9 investigated the light-curing effect, while five other articles evaluated the ceramic translucency. Three studies evaluated the degree of conversion of the resin-matrix cement while four articles assessed the veneer thickness. Results revealed a significant decrease of light transmission through the zirconia with a thickness ranging from 0.1 up to 1.5 mm. However, the ultra-thin thickness around 0.1 and 0.3 mm allowed a full polymerization of the dual-curing resin-matrix cement resulting in the integrity of the interface properties. The light-curing process of resin-matrix cements is also affected by the shade, chemical composition, and microstructure of zirconia and resin cement. Optimal conditions of light-curing are required to reach the threshold intensity of light and energy for polymerization of resin-matrix cements. CONCLUSIONS The increase in zirconia veneer thickness negatively affects the degree of conversion of resin-matrix cements. Also, shade and microstructure are key factor to improve the light curing of resin cements. CLINICAL RELEVANCE Clinicians should consider the zirconia thickness on resin-based cementation since a higher veneer thickness can negatively affect the light irradiation intensity towards the dual-curing resin-matrix cement. Thus, the degree of conversion of the resin-matrix cement can decrease leading to a low chemical stability (e.g., color instability) and poor mechanical properties.
Collapse
|
4
|
Barutcigil K, Büyükkaplan UŞ. The effect of thickness and translucency of polymer-infiltrated ceramic-network material on degree of conversion of resin cements. J Adv Prosthodont 2020; 12:61-66. [PMID: 32377318 PMCID: PMC7183852 DOI: 10.4047/jap.2020.12.2.61] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 02/27/2020] [Accepted: 03/04/2020] [Indexed: 11/30/2022] Open
Abstract
PURPOSE The aim of the present study was to determine the degree of conversion of light- and dual-cured resin cements used in the cementation of all-ceramic restorations under different thicknesses of translucent (T) and high-translucent (HT) polymer-infiltrated ceramic-network (PICN) material. MATERIALS AND METHODS T and HT PICN blocks were prepared at 0.5, 1.0, 1.5, and 2.0 mm thicknesses (n=80). Resin cement samples were prepared with a diameter of 6 mm and a thickness of 100 µm. Light-cured resin cement was polymerized for 30 seconds, and dual-cure resin cement was polymerized for 20 seconds (n=180). Fourier transform infrared spectroscopy (FTIR) was used for degree of conversion measurements. The obtained data were analyzed with ANOVA and Tukey HSD, and independent t-test. RESULTS As a result of FTIR analysis, the degree of conversion of the light-cured resin cement prepared under 1.5- and 2.0-mm-thick T and HT ceramics was found to be lower than that of the control group. Regarding the degree of conversion of the dual-cured resin cement group, there was no significant difference from the control group. CONCLUSION Within the limitation of present study, it can be concluded that using of dual cure resin cement can be suggested for cementation of PICN material, especially for thicknesses of 1.5 mm and above.
Collapse
Affiliation(s)
- Kubilay Barutcigil
- Department of Prosthodontics, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
| | | |
Collapse
|
5
|
Carrabba M, Vichi A, Tozzi G, Louca C, Ferrari M. Cement opacity and color as influencing factors on the final shade of metal-free ceramic restorations. J ESTHET RESTOR DENT 2020; 34:423-429. [PMID: 32282998 DOI: 10.1111/jerd.12587] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2019] [Revised: 03/10/2020] [Accepted: 03/26/2020] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To investigate the influence of opacity and color of luting cements on the final shade of metal-free restorations. MATERIALS AND METHODS Five resin cement colors in combination with four different thicknesses of CAD/CAM ceramic materials were tested, and a composite substrate was used as dentin color reference (n = 3). Specimen color was measured with a spectrophotometer equipped with an integrating sphere before and after cementation (CIELAB). Cement and ceramic color and opacity (TP) were assessed by measuring the tested ceramic thickness as a 1-mm thick disk for each of the cement shades. The differences in color were evaluated (ΔE00 ). Data were statistically analyzed by a Two-Way ANOVA followed by the Tukey Test for post-hoc comparison (P < .05) and multiple comparison Pearson's test (P < .05); the acceptability and perceptibility threshold were evaluated. RESULTS Statistically significant influence was found for factors ceramic thickness and cement shade (P < .001). Perceptible and unacceptable color changes were induced on the final restoration by resin cements (ranging from ΔE00 = 0.69 ± 0.54 to ΔE00 = 5.53 ± 0.46), the correlation between factors became strong (r2 > 0.6) in case of mismatch between color and translucency of cement and ceramic. Only the clear shade in combination with the thickest ceramic, resulted in an imperceptible color change (ΔE00 = 0.69 ± 0.54). CONCLUSIONS The final shade of ceramic restorations can be influenced by resin cements; the magnitude of influence is related to the cement optical properties. CLINICAL SIGNIFICANCE In order to influence the final shade of a ceramic restoration, a cement more opaque than the restorative material should be used. Conversely, in the case of a fitting shade of the restoration, a cement more translucent than the restoration should be used to avoid undesired changes.
Collapse
Affiliation(s)
- Michele Carrabba
- Department of Medical Biotechnologies, Division of Fixed Prosthodontic, University of Siena, Siena, Italy
| | | | - Gianluca Tozzi
- Zeiss Global Centre, School of Engineering, University of Portsmouth, Portsmouth, UK
| | - Chris Louca
- Dental Academy, University of Portsmouth, Portsmouth, UK
| | - Marco Ferrari
- School of Dentistry, Department of Medical Biotechnologies, University of Siena, Siena, Italy
| |
Collapse
|
6
|
Mendonça LMD, Ramalho IS, Lima LASN, Pires LA, Pegoraro TA, Pegoraro LF. Influence of the composition and shades of ceramics on light transmission and degree of conversion of dual-cured resin cements. J Appl Oral Sci 2019; 27:e20180351. [PMID: 31365707 PMCID: PMC6690711 DOI: 10.1590/1678-7757-2018-0351] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2018] [Accepted: 02/01/2019] [Indexed: 12/22/2022] Open
Abstract
Objective Since the transmittance of ceramics can influence the degree of conversion (DC) of resin cements, ceramics composition and shade should be considered in the selection of resin cement. This in vitro study aimed to evaluate the effect of the transmittance of different composition, opacities and shades of ceramics on the degree of conversion of two dual-cured resin cements. Methodology Sixty discs were prepared from low translucency (LT) and medium opacity (MO) lithium disilicate ceramic, and zirconia ceramic (Z). Each group was subdivided into 5 subgroups (n=4) in shades A2, A3.5, B2, C2 and D3. The transmittance measurement was performed in a spectrophotometer. The Variolink II and Rely X U200 resin cements were photoactivated by LED (1400 mW/cm2) for 40 s through the ceramic discs and without the discs (control group). The DC was measured with infrared FTIR spectroscopy, immediately after light activation. Data were analyzed with Kruskall-Wallis and one-way ANOVA, following post-hoc comparisons by Tukey test and Pearson’s correlation test (P<0.05). Results LT ceramic exhibited higher transmittance values compared to MO and Z ceramics. LTA2 and LTB2 showed statistically higher transmittance values compared to MOA2, MOA3.5 and ZA3.5. For Variolink II, the ceramic interposition did not influence the DC, since there were no statistical differences between groups with ceramic interposition and the control group. For Rely X U200 cement, the interposition of some ceramics types/shades (LTA3.5, MOA2, MOA3.5 and ZA3.5) significantly decreased the DC values compared to control group. A positive correlation was found between the ceramic transmittance and DC values of both tested cements. Conclusions. The transmittance and DC values of the cements were influenced by composition and shades of the ceramics. The higher the transmittance of ceramics, the higher the DC values for both cements.
Collapse
Affiliation(s)
| | - Ilana Santos Ramalho
- Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departmento de Prótese e Periodontia, Bauru, São Paulo, Brasil
| | | | - Laís Alcântara Pires
- Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departmento de Prótese e Periodontia, Bauru, São Paulo, Brasil
| | - Thiago Amadei Pegoraro
- Universidade do Sagrado Coração, Faculdade de Odontologia, Departamento de Prótese, Bauru, São Paulo, Brasil
| | - Luiz Fernando Pegoraro
- Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departmento de Prótese e Periodontia, Bauru, São Paulo, Brasil
| |
Collapse
|
7
|
Evaluation of Dual-Cure Resin Cement Polymerization under Different Types and Thicknesses of Monolithic Zirconia. BIOMED RESEARCH INTERNATIONAL 2019; 2019:4567854. [PMID: 30729124 PMCID: PMC6343131 DOI: 10.1155/2019/4567854] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Accepted: 12/26/2018] [Indexed: 02/04/2023]
Abstract
Purpose The aim of the present study was to investigate the effects of the type and thickness of the zirconia material on the microhardness of the underlying dual-cure resin cement. Materials and Methods Eight disk-shaped zirconia specimens with a 4-mm diameter and four varying thicknesses (0.5, 1.0, 1.5, and 2.0 mm) were fabricated from two different monolithic zirconia materials: posterior monolithic zirconia (Prettau) and anterior monolithic zirconia (Prettau Anterior). Dual-cure resin cement specimens with a 4-mm diameter and 5-mm height were prepared using Teflon cylinder molds and activated by light beneath the eight zirconia disks and without any zirconia disk for 20 s (n=12). A total of 108 specimens were embedded in acrylic. Vickers hardness of each specimen was measured at three different depths using a microhardness device with a 50-g load. All data were statistically evaluated using three-way ANOVA, one-way ANOVA, independent samples t-tests, and Bonferroni corrected post hoc tests (α=.05). Results Dual-cure resin cement's microhardness was significantly higher for the samples polymerized beneath anterior monolithic zirconia compared to posterior monolithic zirconia. The hardness decreased as the thickness increased for both types of zirconia; the latter was attributed to an attenuated curing efficiency. Conclusion Microhardness of the dual-cure resin cement is influenced by both the type and the thickness of the monolithic zirconia restoration. Polymerization efficiency for resin cement cured under anterior monolithic zirconia may be superior to cured beneath posterior monolithic zirconia.
Collapse
|
8
|
Turp V, Turkoglu P, Sen D. Influence of monolithic lithium disilicate and zirconia thickness on polymerization efficiency of dual-cure resin cements. J ESTHET RESTOR DENT 2018; 30:360-368. [DOI: 10.1111/jerd.12390] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2018] [Revised: 04/24/2018] [Accepted: 04/25/2018] [Indexed: 02/04/2023]
Affiliation(s)
- Volkan Turp
- Department of Prosthodontics; Istanbul University; Istanbul Turkey
| | - Pinar Turkoglu
- Department of Prosthodontics; Istanbul University; Istanbul Turkey
| | - Deniz Sen
- Department of Prosthodontics; Istanbul University; Istanbul Turkey
| |
Collapse
|
9
|
Caprak YO, Turkoglu P, Akgungor G. Does the Translucency of Novel Monolithic CAD/CAM Materials Affect Resin Cement Polymerization with Different Curing Modes? J Prosthodont 2018; 28:e572-e579. [DOI: 10.1111/jopr.12956] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/12/2018] [Indexed: 12/01/2022] Open
Affiliation(s)
| | - Pinar Turkoglu
- Department of Prosthodontics; Istanbul University Faculty of Dentistry; Istanbul Turkey
| | - Gokhan Akgungor
- Department of Prosthodontics; Istanbul University Faculty of Dentistry; Istanbul Turkey
| |
Collapse
|
10
|
Influence of polymerization time on properties of dual-curing cements in combination with high translucency monolithic zirconia. J Prosthodont Res 2018; 62:468-472. [PMID: 29983378 DOI: 10.1016/j.jpor.2018.06.003] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2017] [Revised: 06/05/2018] [Accepted: 06/10/2018] [Indexed: 11/27/2022]
Abstract
PURPOSE The aim of this in vitro study was to assess conversion degree (DC), micro-hardness (MH) and bond strength of two dual-curing resin cements employed under translucent monolithic zirconia irradiated with different time protocols. METHODS 84 square shaped samples of 1mm thickness were prepared from high translucency zirconia blocks and divided into two groups (n=24) according to the cement employed: (1) Rely-X Ultimate; (2) Panavia SA. Each group was further divided into 3 subgroups (n=8) according to the irradiation time: (a) no light; (b) 20s; (c) 120s. Light curing was performed 60s after the sample was placed on the diamond support of a FT-IR spectrophotometer with a high power multiLED lamp. Final DC% were calculated after 10min. After 24h, Vickers Test on the cement layer was performed. The same protocol was used to lute composite cylinders in order to evaluate microshear bond-strength test. ANOVA and Bonferroni tests were performed to find differences between MH and bond-strength to zirconia, while for DC% the Scheirer-Ray-Hare two-way test was used. RESULTS The two cements reached higher DC% in subgroup (b) and (c). As concern MH, statistics showed an increase in curing time was able to improve MH significantly. Bond-strength was not affected by irradiation time only for Panavia SA. CONCLUSIONS The first null hypothesis has to be rejected since DC% and MH of the dual-cements tested were influenced by the curing time. The second null hypothesis is partially rejected since the bond strength was influenced by the curing time only for Rely-X Ultimate.
Collapse
|
11
|
Rueggeberg FA, Giannini M, Arrais CAG, Price RBT. Light curing in dentistry and clinical implications: a literature review. Braz Oral Res 2017; 31:e61. [PMID: 28902241 DOI: 10.1590/1807-3107bor-2017.vol31.0061] [Citation(s) in RCA: 100] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2017] [Accepted: 05/22/2017] [Indexed: 11/21/2022] Open
Abstract
Contemporary dentistry literally cannot be performed without use of resin-based restorative materials. With the success of bonding resin materials to tooth structures, an even wider scope of clinical applications has arisen for these lines of products. Understanding of the basic events occurring in any dental polymerization mechanism, regardless of the mode of activating the process, will allow clinicians to both better appreciate the tremendous improvements that have been made over the years, and will also provide valuable information on differences among strategies manufacturers use to optimize product performance, as well as factors under the control of the clinician, whereby they can influence the long-term outcome of their restorative procedures.
Collapse
Affiliation(s)
- Frederick Allen Rueggeberg
- Augusta University, Dental College of Georgia, Department of Restorative Sciences, Augusta, GA, United States of America
| | - Marcelo Giannini
- Universidade Estadual de Campinas - Unicamp, Piracicaba Dental School, Department of Restorative Dentistry, Piracicaba, SP, Brazil
| | | | | |
Collapse
|
12
|
Ayres APA, Andre CB, Pacheco RR, Carvalho AO, Bacelar-Sá RC, Rueggeberg FA, Giannini M. Indirect Restoration Thickness and Time after Light-Activation Effects on Degree of Conversion of Resin Cement. Braz Dent J 2015; 26:363-7. [DOI: 10.1590/0103-64402013x0024] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2015] [Accepted: 06/16/2015] [Indexed: 11/22/2022] Open
Abstract
<p>This study evaluated the effects of indirect restorative materials, curing conditions and time on the degree of conversion (DC) of a dual-cured resin cement using infrared spectroscopy. The resin cement (RelyX Unicem 2, 3M ESPE) was applied to the diamond surface of a horizontal attenuated-total-reflectance unit and activated using one of following conditions: self-cure, direct light exposure, light exposure through indirect restorative materials (resin nano-ceramic: Lava Ultimate, 3M ESPE or feldspathic ceramic: Vita Blocks Mark II, Vita Zahnfabrik). Four thicknesses (0.5, 1.0, 1.5 or 2.0 mm) of each indirect material were analyzed, and the light-activation was performed using a blue LED light. Data (n=5) were analyzed by three-way ANOVA, Tukey's post hoc and Dunnett's tests (α=5%). No significant differences in DC were observed between indirect materials of similar thickness. All groups exhibited higher DC after 10 min than after 5 min. At both times points, the self-cure group exhibited significantly lower DC than all the light exposure groups. Only when the overlying indirect restoration had a thickness of 2 mm did DC decrease significantly. The presence of a thick, indirect restoration can decrease the DC of resin cement. DC after 10 min was higher than after 5 min. The self-cure mode yielded lower DC than the light-activating one.</p>
Collapse
|
13
|
Gultekin P, Pak Tunc E, Ongul D, Turp V, Bultan O, Karataslı B. Curing efficiency of dual-cure resin cement under zirconia with two different light curing units. J Istanb Univ Fac Dent 2015; 49:8-16. [PMID: 28955530 PMCID: PMC5573479 DOI: 10.17096/jiufd.97059] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2014] [Accepted: 02/09/2015] [Indexed: 11/19/2022] Open
Abstract
Purpose: Adequate polymerization is a crucial factor in obtaining optimal physical properties and a satisfying
clinical performance from composite resin materials. The aim of this study was to evaluate the polymerization efficiency of
dual-cure resin cement cured with two different light curing units under zirconia structures having differing thicknesses. Materials and Methods: 4 zirconia discs framework in 4 mm diameter and in 0.5 mm, 1 mm and 1.5 mm thickness
were prepared using computer-aided design system. One of the 0.5 mm-thick substructures was left as mono-layered
whereas others were layered with feldspathic porcelain of same thickness and ceramic samples with 4 different
thicknesses (0.5, 1, 1.5 and 2.0 mm) were prepared. For each group (n=12) resin cement was light cured in
polytetrafluoroethylene molds using Light Emitting Diode (LED) or Quartz-Tungsten Halogen (QHT) light curing
units under each of 4 zirconia based discs (n=96). The values of depth of cure (in mm) and the Vickers Hardness
Number values (VHN) were evaluated for each specimen. Results: The use of LED curing unit produced a greater depth of cure compared to QTH under ceramic discs
with 0.5 and 1 mm thickness (p<0.05).At 100μm and 300 μm depth, the LED unit produced significantly greater
VHN values compared to the QTH unit (p<0.05). At 500 μm depth, the difference between the VHN values of
LED and QTH groups were not statistically significant. Conclusion: Light curing may not result in adequate resin cement polymerization under thick zirconia structures.
LED light sources should be preferred over QTH for curing dual-cure resin cements, especially for those under thicker zirconia restorations.
Collapse
Affiliation(s)
- Pınar Gultekin
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Turkey
| | - Elif Pak Tunc
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Turkey
| | - Deger Ongul
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Turkey
| | - Volkan Turp
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Turkey
| | - Ozgur Bultan
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Turkey
| | - Burcin Karataslı
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Turkey
| |
Collapse
|
14
|
Ilie N, Stawarczyk B. Quantification of the amount of blue light passing through monolithic zirconia with respect to thickness and polymerization conditions. J Prosthet Dent 2015; 113:114-21. [DOI: 10.1016/j.prosdent.2014.08.013] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2014] [Revised: 08/28/2014] [Accepted: 08/28/2014] [Indexed: 10/24/2022]
|
15
|
Turp V, Ongul D, Gultekin P, Bultan O, Karataslı B, Pak Tunc E. Polymerization efficiency of two dual-cure cements through dental ceramics. J Istanb Univ Fac Dent 2015; 49:10-18. [PMID: 28955520 PMCID: PMC5573458 DOI: 10.17096/jiufd.25575] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2014] [Accepted: 02/02/2015] [Indexed: 11/29/2022] Open
Abstract
Purpose: The aim of this study was to evaluate the effect of thickness of zirconia on curing efficiency of resin cements. Materials and Methods: Four discs with 4.0 mm in diameter were prepared from non-HIP translucent zirconia blocks using a CAD/CAM system and feldspathic ceramic was layered onto discs.
Thus, 4 ceramic disc samples were fabricated: (G) 0.5 mm zirconia- as a control group, (G1) 0.5 mm zirconia and 0.5 mm feldspathic,
(G2) 1.0 mm zirconia and 0.5 mm feldspathic and (G3) 2.0 mm zirconia and 0.5 mm feldspathic ceramic layer. 2 different dual cure cements were polymerized
using a LED curing unit. Degree of conversion was evaluated using Vickers Hardness Test and depths of cure of samples were measured. Data were analyzed statistically
using One-way ANOVA and Tukey’s HSD test (p<0.05). Results: Microhardness and depth of cure values were different under same thickness of ceramic discs for two resin cements.
As the thickness of the zirconia discs increased, the microhardness values and depth of cure decreased. Conclusion: Photocuring time cannot be the same for all clinical conditions, under thicker zirconia restorations (>2.0 mm),
an extended period of light curing or a light unit with a high irradiance should be used.
Collapse
Affiliation(s)
- Volkan Turp
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University Turkey
| | - Deger Ongul
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University Turkey
| | - Pınar Gultekin
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University Turkey
| | - Ozgur Bultan
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University Turkey
| | - Burcin Karataslı
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University Turkey
| | - Elif Pak Tunc
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University Turkey
| |
Collapse
|
16
|
Shiomuki D, Minami H, Tanaka T, Suzuki S. Influence of light irradiation on Vickers hardness of dual-cure cement polymerized under restorations. Dent Mater J 2014; 32:449-55. [PMID: 23719007 DOI: 10.4012/dmj.2012-306] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study evaluated, by measuring Vickers hardness (Hv), the effects of these factors on the degree of polymerization of dual-cure cement (Panavia F2.0) placed under a restoration: light transmission property of restoratives materials, distance from the directly irradiated surface, and elapsed time after light irradiation. Two materials were used for the restoration: silver-palladium-copper-gold alloy (Alloy) versus zirconia (ZR). Restorations were cemented on bovine enamel by dual-cure cement. At 30 min, 2 h, 6 h, 1 day, and 1 week after definitive irradiation, Hv values at the enamel side of cement were evaluated at three measuring points: two points at the left and right margins and one point at the center. Data were analyzed by two-way ANOVA with Bonferroni correction (α=0.05). With the Alloy restoration, Hv value at the center was significantly lower than those at the margins at 30 min after irradiation. For both Alloy and ZR restorations, Hv value at each measuring point continued to increase significantly up to 6 h.
Collapse
Affiliation(s)
- Daisaku Shiomuki
- Fixed Prosthetic Clinic, Kagoshima University Medical and Dental Hospital, 8-35-1 Sakuragaoka, Kagoshima 890-8544, Japan
| | | | | | | |
Collapse
|
17
|
Cekic-Nagas I, Egilmez F, Ergun G. Comparison of light transmittance in different thicknesses of zirconia under various light curing units. J Adv Prosthodont 2012; 4:93-6. [PMID: 22737314 PMCID: PMC3381209 DOI: 10.4047/jap.2012.4.2.93] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2012] [Revised: 05/02/2012] [Accepted: 05/04/2012] [Indexed: 12/13/2022] Open
Abstract
PURPOSE The objective of this study was to compare the light transmittance of zirconia in different thicknesses using various light curing units. MATERIALS AND METHODS A total of 21 disc-shaped zirconia specimens (5 mm in diameter) in different thicknesses (0.3, 0.5 and 0.8 mm) were prepared. The light transmittance of the specimens under three different light-curing units (quartz tungsten halogen, light-emitting diodes and plasma arc) was compared by using a hand-held radiometer. Statistical significance was determined using two-way ANOVA (α=.05). RESULTS ANOVA revealed that thickness of zirconia and light curing unit had significant effects on light transmittance (P<.001). CONCLUSION Greater thickness of zirconia results in lower light transmittance. Light-emitting diodes light-curing units might be considered as effective as Plasma arc light-curing units or more effective than Quartz-tungsten-halogen light-curing units for polymerization of the resin-based materials.
Collapse
Affiliation(s)
- Isil Cekic-Nagas
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara, Turkey
| | | | | |
Collapse
|