1
|
Yao Y, Kang H, Cheng Y, Su X, Wang B. Inflammatory Progression in Patients Undergoing Extracorporeal Membrane Oxygenation. Curr Mol Med 2024; 24:844-855. [PMID: 37340745 DOI: 10.2174/1566524023666230619102723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2022] [Revised: 04/24/2023] [Accepted: 05/04/2023] [Indexed: 06/22/2023]
Abstract
Extracorporeal membrane oxygenation (ECMO) is identified as a novel therapeutic strategy that offers short-term support to the metabolism of the heart and lungs in humans. Recently, the clinical centers, which provide ECMO has increased rapidly worldwide. The indications for the use of ECMO in daily clinical practice were broadened dynamically. However, even with the widespread adoption of ECMO, it still remains significant morbidity and mortality, and the underlying mechanisms are still not elucidated. Notably, one of the vital complications during ECMO was proposed as the inflammatory progression within the extracorporeal circulation. via the development of inflammatory response, patients with ECMO may further suffer from systemic inflammatory response syndrome (SIRS), posing serious risks to human health. Recently, growing evidence confirmed that through exposure of blood into the ECMO circuit could lead to the stimulation of the immune system which also facilitated the inflammatory response and systemic impaired. In the current review, the pathological development of inflammatory progression in patients with ECMO is well-listed. Furthermore, the relationship between immune-related activation and the development of inflammation is also summarized, which may further help us to decide the therapeutic strategies in daily clinical practice.
Collapse
Affiliation(s)
- Yan'er Yao
- Department of Cardiology, the Xiamen Cardiovascular Hospital of Xiamen University, Xiamen, Fujian, China
| | - Huiyuan Kang
- Department of Cardiology, the Xiamen Cardiovascular Hospital of Xiamen University, Xiamen, Fujian, China
| | - Ye Cheng
- Department of Cardiology, the Xiamen Cardiovascular Hospital of Xiamen University, Xiamen, Fujian, China
| | - Xin Su
- Department of Cardiology, the Xiamen Cardiovascular Hospital of Xiamen University, Xiamen, Fujian, China
| | - Bin Wang
- Department of Cardiology, the Xiamen Cardiovascular Hospital of Xiamen University, Xiamen, Fujian, China
| |
Collapse
|
2
|
Dopico PJ, Le MCN, Burgess B, Yang Z, Zhao Y, Wang Y, George TJ, Fan ZH. Longitudinal Study of Circulating Biomarkers in Patients with Resectable Pancreatic Ductal Adenocarcinoma. BIOSENSORS 2022; 12:206. [PMID: 35448266 PMCID: PMC9028387 DOI: 10.3390/bios12040206] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 03/23/2022] [Accepted: 03/28/2022] [Indexed: 05/12/2023]
Abstract
While patients with resectable pancreatic ductal adenocarcinoma (PDAC) show improved survival compared to their non-resectable counterparts, survival remains low owing to occult metastatic disease and treatment resistance. Liquid biopsy based on circulating tumor cells (CTCs) and cell-free DNA (cfDNA) has been shown to predict recurrence and treatment resistance in various types of cancers, but their utility has not been fully demonstrated in resectable PDAC. We have simultaneously tracked three circulating biomarkers, including CTCs, cfDNA, and circulating tumor DNA (ctDNA), over a period of cancer treatment using a microfluidic device and droplet digital PCR (ddPCR). The microfluidic device is based on the combination of filtration and immunoaffinity mechanisms. We have measured CTCs, cfDNA, and ctDNA in a cohort of seven resectable PDAC patients undergoing neoadjuvant therapy followed by surgery, and each patient was followed up to 10 time points over a period of 4 months. CTCs were detectable in all patients (100%) at some point during treatment but were detectable in only three out of six patients (50%) prior to the start of treatment. Median cfDNA concentrations remained comparable to negative controls throughout treatment. ddPCR was able to find KRAS mutations in six of seven patients (86%); however, these mutations were present in only two of seven patients (29%) prior to treatment. Overall, the majority of circulating biomarkers (81% for CTCs and 91% for cfDNA/ctDNA) were detected after the start of neoadjuvant therapy but before surgery. This study suggests that a longitudinal study of circulating biomarkers throughout treatment provides more useful information than those single time-point tests for resectable PDAC patients.
Collapse
Affiliation(s)
- Pablo J. Dopico
- Interdisciplinary Microsystems Group, Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL 32611, USA; (P.J.D.); (M.-C.N.L.)
| | - Minh-Chau N. Le
- Interdisciplinary Microsystems Group, Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL 32611, USA; (P.J.D.); (M.-C.N.L.)
| | - Benjamin Burgess
- UF Health Cancer Center, University of Florida, 2033 Mowry Rd., Gainesville, FL 32610, USA;
| | - Zhijie Yang
- Atila Biosystems, 740 Sierra Vista Ave., Unit E, Mountain View, CA 94043, USA; (Z.Y.); (Y.Z.); (Y.W.)
| | - Yu Zhao
- Atila Biosystems, 740 Sierra Vista Ave., Unit E, Mountain View, CA 94043, USA; (Z.Y.); (Y.Z.); (Y.W.)
| | - Youxiang Wang
- Atila Biosystems, 740 Sierra Vista Ave., Unit E, Mountain View, CA 94043, USA; (Z.Y.); (Y.Z.); (Y.W.)
| | - Thomas J. George
- UF Health Cancer Center, University of Florida, 2033 Mowry Rd., Gainesville, FL 32610, USA;
- Department of Medicine, University of Florida, 1600 SW Archer Rd., Gainesville, FL 32610, USA
| | - Z. Hugh Fan
- Interdisciplinary Microsystems Group, Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL 32611, USA; (P.J.D.); (M.-C.N.L.)
- UF Health Cancer Center, University of Florida, 2033 Mowry Rd., Gainesville, FL 32610, USA;
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611, USA
| |
Collapse
|
3
|
Sahlin A, Blomgran R, Berlin G. Granulocyte concentrates prepared from residual leukocyte units produced by the Reveos automated blood processing system. Transfus Apher Sci 2019; 59:102682. [PMID: 31812492 DOI: 10.1016/j.transci.2019.102682] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Revised: 11/08/2019] [Accepted: 11/11/2019] [Indexed: 10/25/2022]
Abstract
BACKGROUND Granulocyte concentrates are mainly derived by apheresis technique from donors stimulated with granulocyte colony-stimulating factor and steroids. The automated blood processing system Reveos, which is now increasingly used across the world, separates whole blood into four components, including a residual leukocyte unit containing granulocytes. The aim of this study was to produce an alternative granulocyte concentrate from leukocyte units produced by the Reveos system, and to assess the function of the granulocytes. METHODS The number of granulocytes was measured in residual leukocyte units, derived from whole blood donations, with different volumes ranging from 10 to 40 ml. After deciding the optimal volume of the leukocyte unit (30 ml), ten ABO-matched units were pooled to form a granulocyte concentrate. The function of the granulocytes from residual leukocyte units was assessed by analyzing surface markers, phagocytosis of yeast, and production of reactive oxygen species. RESULTS Residual leukocyte units with a volume of 30 ml contained a median number of 0,7 × 109 granulocytes, and granulocyte concentrates prepared from ten pooled 30 ml-leukocyte units contained a median number of 6,3 × 109 granulocytes. Granulocytes derived from residual leukocyte units displayed surface markers associated with granulocyte function, and capability to phagocytose yeast and produce reactive oxygen species. CONCLUSIONS Granulocyte concentrates prepared from residual leukocyte units contain in vitro functional granulocytes and may be considered as an alternative product in acute situations before regular granulocyte concentrates from stimulated donors are available.
Collapse
Affiliation(s)
- Angelica Sahlin
- Department of Clinical Immunology and Transfusion Medicine, Department of Clinical and Experimental Medicine, Faculty of Medicine and Health Sciences, Linköping University, 581 85 Linköping, Sweden
| | - Robert Blomgran
- Division of Medical Microbiology, Department of Clinical and Experimental Medicine, Faculty of Medicine and Health Sciences, Linköping University, 581 85 Linköping, Sweden
| | - Gösta Berlin
- Department of Clinical Immunology and Transfusion Medicine, Department of Clinical and Experimental Medicine, Faculty of Medicine and Health Sciences, Linköping University, 581 85 Linköping, Sweden.
| |
Collapse
|
4
|
Quality Assessment of Platelet-Rich Fibrin-Like Matrix Prepared from Whole Blood Samples after Extended Storage. Biomedicines 2017; 5:biomedicines5030057. [PMID: 28926988 PMCID: PMC5618315 DOI: 10.3390/biomedicines5030057] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2017] [Revised: 09/11/2017] [Accepted: 09/14/2017] [Indexed: 12/15/2022] Open
Abstract
The platelet-rich fibrin–like matrix (PRFM) is usually prepared onsite and immediately used for regenerative therapy. Nonetheless, to meet the clinical necessity of preserving the PRFM without quality deterioration, we developed a method for preparation of PRFMs from short-term-stored whole blood (WB) samples. In this study, to evaluate the practical expiration date of storage, we extended the storage time of WB samples from 2 to 7 days and assessed the quality of the resulting PRFMs. WB samples collected with acid-citrate-dextrose were stored with gentle agitation at ambient temperature. To prepare PRFMs, the stored WB samples were mixed with CaCl2 in glass tubes and centrifuged. Fibrin fiber networks, CD41 and CD62P expression, and Platelet Derived Growth Factor-BB (PDGF-BB) levels were examined by scanning electron microscopy (SEM), flow cytometry, and an Enzyme-Linked ImmunoSorbent Assay (ELISA), respectively. Long-term storage had no significant effect on either blood cell counts or platelet functions tested. The resulting PRFMs were visually identical to freshly prepared ones. PDGF-BB levels did not markedly decrease in a time-dependent manner. However, fibrin fibers gradually became thinner after storage. Although the coagulation activity may diminish, we propose that PRFMs can be prepared—without evident loss of quality—from WB samples stored for up to 7 days by our previously developed method.
Collapse
|
5
|
Ziemann M, Thiele T. Transfusion-transmitted CMV infection - current knowledge and future perspectives. Transfus Med 2017. [PMID: 28643867 DOI: 10.1111/tme.12437] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Transmission of human cytomegalovirus (CMV) via transfusion (TT-CMV) may still occur and remains a challenge in the treatment of immunocompromised CMV-seronegative patients, e.g. after stem cell transplantation, and for low birthweight infants. Measures to reduce the risk of TT-CMV have been evaluated in clinical studies, including leucocyte depletion of cellular blood products and/or the selection of CMV-IgG-negative donations. Studies in large blood donor cohorts indicate that donations from newly CMV-IgG-positive donors should bear the highest risk for transmitting CMV infections because they contain the highest levels of CMV-DNA, and early CMV antibodies cannot neutralise CMV. Based on this knowledge, rational strategies to reduce the residual risk of TT-CMV using leucoreduced blood products could be designed. However, there is a lack of evidence that CMV is still transmitted by transfusion of leucoreduced units. In low birthweight infants, most (if not all) CMV infections are caused by breast milk feeding or congenital transmission rather than by transfusion of leucoreduced blood products. For other patients at risk, no definitive data exist about the relative importance of alternative transmission routes of CMV compared to blood transfusion. As a result, only the conduction of well-designed studies addressing strategies to prevent TT-CMV and the thorough examination of presumed cases of TT-CMV will achieve guidance for the best transfusion regimen in patients at risk.
Collapse
Affiliation(s)
- M Ziemann
- Institut für Transfusionsmedizin, Universitätsklinikum Schleswig Holstein, Lübeck, Germany
| | - T Thiele
- Institut für Immunologie und Transfusionsmedizin, Abteilung Transfusionsmedizin, Universitätsmedizin Greifswald, Greifswald, Germany
| |
Collapse
|
6
|
Isobe K, Suzuki M, Watanabe T, Kitamura Y, Suzuki T, Kawabata H, Nakamura M, Okudera T, Okudera H, Uematsu K, Nakata K, Tanaka T, Kawase T. Platelet-rich fibrin prepared from stored whole-blood samples. Int J Implant Dent 2017; 3:6. [PMID: 28251561 PMCID: PMC5332319 DOI: 10.1186/s40729-017-0068-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2016] [Accepted: 02/15/2017] [Indexed: 11/29/2022] Open
Abstract
Background In regenerative therapy, self-clotted platelet concentrates, such as platelet-rich fibrin (PRF), are generally prepared on-site and are immediately used for treatment. If blood samples or prepared clots can be preserved for several days, their clinical applicability will expand. Here, we prepared PRF from stored whole-blood samples and examined their characteristics. Methods Blood samples were collected from non-smoking, healthy male donors (aged 27–67 years, N = 6), and PRF clots were prepared immediately or after storage for 1–2 days. Fibrin fiber was examined by scanning electron microscopy. Bioactivity was evaluated by means of a bioassay system involving human periosteal cells, whereas PDGF-BB concentrations were determined by an enzyme-linked immunosorbent assay. Results Addition of optimal amounts of a 10% CaCl2 solution restored the coagulative ability of whole-blood samples that contained an anticoagulant (acid citrate dextrose) and were stored for up to 2 days at ambient temperature. In PRF clots prepared from the stored whole-blood samples, the thickness and cross-links of fibrin fibers were almost identical to those of freshly prepared PRF clots. PDGF-BB concentrations in the PRF extract were significantly lower in stored whole-blood samples than in fresh samples; however, both extracts had similar stimulatory effects on periosteal-cell proliferation. Conclusions Quality of PRF clots prepared from stored whole-blood samples is not reduced significantly and can be ensured for use in regenerative therapy. Therefore, the proposed method enables a more flexible treatment schedule and choice of a more suitable platelet concentrate immediately before treatment, not after blood collection.
Collapse
Affiliation(s)
| | | | | | | | - Taiji Suzuki
- Tokyo Plastic Dental Society, Kita-ku, Tokyo, Japan
| | | | | | | | | | - Kohya Uematsu
- Division of Oral Implantology, Niigata University Medical and Dental Hospital, Niigata, Japan
| | - Koh Nakata
- Bioscience Medical Research Center, Niigata University Medical and Dental Hospital, Niigata, Japan
| | - Takaaki Tanaka
- Department of Materials Science and Technology, Niigata University, Niigata, Japan
| | - Tomoyuki Kawase
- Division of Oral Bioengineering, Institute of Medicine and Dentistry, Niigata University, Niigata, Japan.
| |
Collapse
|
7
|
Slichter SJ, Abrams K, Bailey SL, Pellham E, Gettinger I, Christoffel T, Gaur L, Latchman Y, Nelson K, Bolgiano D. Further studies to evaluate methods of leucoreduction to prevent alloimmune platelet refractoriness and induce tolerance in a dog platelet transfusion model. Vox Sang 2016; 111:62-70. [PMID: 27007858 DOI: 10.1111/vox.12388] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2015] [Revised: 01/14/2016] [Accepted: 01/14/2016] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Three leucoreduction filters were evaluated - when used alone or combined with centrifuge leucoreduction (C-LR) - to prevent alloimmune platelet refractoriness in a dog platelet transfusion model. MATERIALS AND METHODS Donor platelet-rich plasma (PRP) or buffy coat (BC) platelets were either filter leucoreduced (F-LR) or F-LR/C-LR, (51) Cr radiolabelled and transfused. Weekly transfusions were given for up to 8 weeks or until platelet refractoriness. Recipients who accepted treated transfusions were then given non-leucoreduced (non-LR) platelets to determine whether donor-specific tolerance had been induced. RESULTS Acceptance of F-LR PRP transfusions ranged from 29% to 66%. F-LR/C-LR transfusions prepared from PRP were accepted by 92%, from BC by 63% and from pooled PRP by 75% of recipients (p=NS); overall acceptance rate of F-LR/C-LR transfusions was 83%. Tolerance to subsequent non-LR transfusions occurred in 45% of the F-LR-/C-LR-accepting recipients unrelated to DR-B compatibility between donors and recipients (P = 0·18). CONCLUSION In a dog platelet transfusion model, acceptance of donor platelets required combining F-LR with C-LR as apparently each process removes different immunizing WBCs.
Collapse
Affiliation(s)
- S J Slichter
- Research Institute, Bloodworks Northwest, Seattle, WA, USA.,University of Washington School of Medicine, Seattle, WA, USA
| | - K Abrams
- Fred Hutchinson Cancer Research Center, Seattle, WA, USA
| | | | - E Pellham
- Research Institute, Bloodworks Northwest, Seattle, WA, USA
| | - I Gettinger
- Research Institute, Bloodworks Northwest, Seattle, WA, USA
| | - T Christoffel
- Research Institute, Bloodworks Northwest, Seattle, WA, USA
| | - L Gaur
- Ascendant Laboratories, Bellevue, WA, USA.,Washington Center for Pain Management, Bellevue, WA, USA
| | | | - K Nelson
- Research Institute, Bloodworks Northwest, Seattle, WA, USA
| | - D Bolgiano
- Research Institute, Bloodworks Northwest, Seattle, WA, USA
| |
Collapse
|
8
|
Eckstein M, Zimmermann R, Roth T, Hauck-Dlimi B, Strasser EF, Xiang W. The effects of an overnight holding of whole blood at room temperature on haemoglobin modification and in vitro markers of red blood cell aging. Vox Sang 2015; 108:359-67. [PMID: 25753392 DOI: 10.1111/vox.12235] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2014] [Revised: 10/16/2014] [Accepted: 11/18/2014] [Indexed: 11/29/2022]
Abstract
BACKGROUND Some effects of the red blood cell (RBC) storage lesion are well documented whereas others are not. Whether a period of room temperature hold (RTH) during RBC production enhances the RBC storage lesion has remained controversial. In this study, we compared whole blood (WB)-derived RBCs produced after 24-h RTH with rapidly cooled (RC) RBCs and tested them for classical metabolic markers and signs of oxidative damage. STUDY DESIGN AND METHODS SAGM-RBCs were prepared from mixed and split pairs (n = 12) of WB units. RBCs prepared after a 24-h period of RTH on day+1 after collection (RTH-RBCs) were compared with RC-RBCs. All RBCs were stored at 4°C for 42 days with assay of in vitro variables on days+1, +15, +22, +29 and +42. The study examined standard quality parameters, glutathione, catalase and superoxide dismutase (SOD) activities, and indicative markers of oxidative cell damage including post-translational haemoglobin modification, malondialdehyde (MDA), and phosphatidylserine expression. RESULTS RTH-RBCs exhibited decreased levels of potassium (1·98 ± 0·26 vs. 5·23 ± 0·65 mmol/l) and of 2,3-diphosphoglycerate (2,3-DPG) on day+1 compared with RC-RBCs. Haemolysis rate on day+42 was higher in RTH-RBCs than in RC-RBCs (0·52 ± 0·13 vs. 0·37 ± 0·12%). The phosphatidylserine expression amounted to 0·25 ± 0·20% in RTH-RBCs and 0·07 ± 0·12% in RC-RBCs. Haemoglobin modification was not different between both RBC groups. RTH-RBCs showed slightly higher MDA concentration on days +29 and +42. CONCLUSIONS RC-RBCs and RTH-RBCs show only small differences of classical in vitro parameters and no relevant differences in antioxidative metabolism and oxidative haemoglobin modification. These findings do not explain the loss observed in in vivo survival studies with RBCs.
Collapse
Affiliation(s)
- M Eckstein
- Department of Transfusion Medicine and Haemostaseology, University Hospital Erlangen, Erlangen, Germany
| | | | | | | | | | | |
Collapse
|
9
|
van der Meer PF, de Korte D. The Effect of Holding Times of Whole Blood and Its Components During Processing on In Vitro and In Vivo Quality. Transfus Med Rev 2015; 29:24-34. [DOI: 10.1016/j.tmrv.2014.10.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2014] [Revised: 10/14/2014] [Accepted: 10/17/2014] [Indexed: 11/25/2022]
|
10
|
Chan KSK, Sparrow RL. Microparticle profile and procoagulant activity of fresh-frozen plasma is affected by whole blood leukoreduction rather than 24-hour room temperature hold. Transfusion 2014; 54:1935-44. [PMID: 24635475 DOI: 10.1111/trf.12602] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2013] [Revised: 01/07/2014] [Accepted: 01/10/2014] [Indexed: 02/06/2023]
Abstract
BACKGROUND Microparticles (MPs) are small phospholipid-containing vesicles that have procoagulant properties. MPs are thought to contribute to the hemostatic potential of plasma. This study investigated the effects of whole blood (WB) hold time and leukoreduction (LR) on the MP profile and hemostatic potential of fresh-frozen plasma (FFP). STUDY DESIGN AND METHODS WB units (n=12) from healthy donors were divided into two pairs and each pair was held at 20 to 24°C for 6 or 24 hours. At the designated hold time, 1 unit from the pair was LR while the other unit was not LR. FFP was prepared by standard procedures, aliquoted, and frozen. The MP content was determined by flow cytometry using an absolute count assay and specific labels for red blood cells (CD235a), platelets (CD41), and phosphatidylserine (PS). The hemostatic potential was determined by thrombelastography (TEG) and coagulation factor assays. RESULTS Compared to non-LR-FFP, LR-FFP had significantly lower numbers of MPs, particularly CD41+ MPs and PS-positive MPs (p<0.03). LR-FFP, compared to non-LR-FFP, had a slower clot formation time (p=0.002); lower clot strength (p<0.001); and lower Factor (F)VIII, FXII, and fibrinogen levels (p<0.01). With longer WB hold time, the TEG profile was unchanged, although FVIII levels were decreased as expected (p<0.01). On average FFP units met quality requirements. CONCLUSION LR of WB resulted in lower hemostatic potential of FFP in conjunction with depletion of MPs and coagulation factors. Longer WB hold time did not significantly affect the hemostatic potential of FFP as measured by TEG. Acceptable hemostatic quality was maintained for all FFP processing conditions studied.
Collapse
Affiliation(s)
- Kasey Sze-Kei Chan
- Research and Development, Australian Red Cross Blood Service, Melbourne, Victoria, Australia
| | | |
Collapse
|
11
|
Radwanski K, Garraud O, Cognasse F, Hamzeh-Cognasse H, Payrat JM, Min K. The effects of red blood cell preparation method on in vitro markers of red blood cell aging and inflammatory response. Transfusion 2013; 53:3128-38. [PMID: 23461802 DOI: 10.1111/trf.12143] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2012] [Revised: 01/11/2013] [Accepted: 01/15/2013] [Indexed: 12/26/2022]
Abstract
BACKGROUND Studies are currently under way examining whether the age of stored red blood cells (RBCs) affects clinical outcome in transfusion recipients. The effects of storage duration on the RBC storage lesion are well documented, while fewer studies are available regarding the effect of RBC production method. In this study, we compared in vitro RBC quality variables and markers of inflammatory response in apheresis and whole blood (WB)-derived RBCs, specifically those prepared after an overnight room temperature hold (RTH) of WB. STUDY DESIGN AND METHODS SAGM RBCs, prepared from WB after overnight RTH (n = 10), were compared to SAGM RBCs prepared using an apheresis device (Alyx, n = 10). As a control, SAGM RBCs were also prepared within 2 hours of WB collection (2-hr WB, n = 10). All RBCs were stored at 4°C for 42 days with weekly assay of in vitro variables, cytokines and/or chemokines, and neutrophil activation after incubation with RBC supernatant. RESULTS RTH WB RBCs exhibited decreased levels of 2,3-diphosphoglycerate acid (2.3 μmol/g hemoglobin [Hb] ± 2.1 vs. 13.7 ± 1.3 μmol/g Hb) and morphology (160 ± 10 vs. 192 ± 5) on Day 1 and increased hemolysis (0.45 ± 0.21% vs. 0.31 ± 0.09%) and microparticles (6.1 ± 2.8/10(3) RBCs vs. 3.9 ± 1.1/10(3) RBCs) on Day 42 compared to apheresis RBCs. Gro-α and ENA-78 cytokine levels were significantly higher in RTH WB than Alyx RBCs during storage. CD11b expression was highest in neutrophils exposed to supernatant from RTH WB RBCs (p < 0.05). CONCLUSION RBC preparation method has a meaningful effect on the RBC storage lesion, which should be taken into account in addition to length of storage.
Collapse
Affiliation(s)
- Katherine Radwanski
- Fenwal, Inc., Lake Zurich, Illinois, GIMAP-EA3064; Université de Lyon, Saint-Étienne, France; EFS Auvergne-Loire, Saint-Etienne, France
| | | | | | | | | | | |
Collapse
|
12
|
Slichter SJ, Corson J, Jones MK, Christoffel T, Pellham E, Bolgiano D. Platelet concentrates prepared after a 20- to 24-hour hold of the whole blood at 22°C. Transfusion 2012; 52:2043-8. [PMID: 22320682 DOI: 10.1111/j.1537-2995.2011.03546.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND The Food and Drug Administration (FDA) requires that red blood cells must be refrigerated within 8 hours of whole blood collection. Longer storage of whole blood at 22°C before component preparation would have many advantages. STUDY DESIGN AND METHODS Two methods of holding whole blood for 20 to 24 hours at room temperature were evaluated, refrigerated plates or a 23°C incubator. After extended whole blood storage, platelet (PLT) concentrates were prepared from PLT-rich plasma on Day 1 postdonation, and the PLTs were stored for 6 more days. On Day 7 of PLT storage, blood was drawn from each subject to prepare fresh PLTs. The stored and fresh PLTs were radiolabeled and transfused into their donor. RESULTS Eleven subjects' whole blood was stored using refrigerated butanediol plates (Compocool, Fresenius), and 10 using an incubator. Poststorage PLT recoveries averaged 47 ± 13% versus 53 ± 11% and survivals averaged 4.6 ± 1.7 days versus 4.7 ± 0.9 days for Compocool versus incubator storage, respectively (p = NS). With all results, poststorage PLT recoveries averaged 75 ± 10% of fresh and survivals 57 ± 13% of fresh; PLT recoveries met FDA guidelines for poststorage PLT viability but not survivals. CONCLUSION Seven-day poststorage PLT viability is comparable when whole blood is stored for 22 ± 2 hours at 22°C using either refrigerated plates or an incubator to maintain temperature before preparing PLT concentrates.
Collapse
Affiliation(s)
- Sherrill J Slichter
- Puget Sound Blood Center and University of Washington School of Medicine, Seattle, Washington 98104-1256, USA.
| | | | | | | | | | | |
Collapse
|
13
|
Hinojosa R, Bryant BJ. WBC reduction filtration efficacy performed at varying time intervals post-collection. Transfusion 2011; 51:2758-60. [DOI: 10.1111/j.1537-2995.2011.03444.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
14
|
Lu FQ, Kang W, Peng Y, Wang WM. Characterization of blood components separated from donated whole blood after an overnight holding at room temperature with the buffy coat method. Transfusion 2011; 51:2199-207. [DOI: 10.1111/j.1537-2995.2011.03137.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
15
|
Abstract
Blood services routinely separate whole blood into components that are then stored under different conditions. The storage conditions used for whole blood prior to separation must therefore be a compromise between the needs of the red cells (which benefit from refrigeration) and plasma and platelets (which are better preserved at ambient temperature). For many years, the approach has been to manufacture plasma and platelet components on the day of blood collection, and to refrigerate any unprocessed blood for manufacture into red cell components on the following day. However, this can make it challenging to maintain adequate stocks of all components. The European practice of 'ambient hold' of whole blood for up to 24 hours prior to processing allows greater flexibility in blood component manufacture, and the data reviewed suggest there is relatively little impact on the quality of red cell or plasma components, and an improvement in the quality of platelet components.
Collapse
Affiliation(s)
- Stephen Thomas
- Components Development Laboratory, NHS Blood and Transplant, Brentwood, Essex, UK.
| |
Collapse
|
16
|
van der Meer PF, Cancelas JA, Cardigan R, Devine DV, Gulliksson H, Sparrow RL, Vassallo RR, de Wildt-Eggen J, Baumann-Baretti B, Hess JR. Evaluation of overnight hold of whole blood at room temperature before component processing: effect of red blood cell (RBC) additive solutions on in vitro RBC measures. Transfusion 2011; 51 Suppl 1:15S-24S. [PMID: 21223291 DOI: 10.1111/j.1537-2995.2010.02959.x] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND Whole blood (WB) can be held at room temperature (18-25°C) up to 8 hours after collection; thereafter the unit must be refrigerated, rendering it unsuitable for platelet (PLT) production. Overnight hold at room temperature before processing has logistic advantages, and we evaluated this process in an international multicenter study for both buffy coat (BC)- and PLT-rich plasma (PRP)-based blood components and compared three red blood cell (RBC) additive solutions (ASs) for their ability to offset effects of overnight hold. STUDY DESIGN AND METHODS Nine centers participated; seven used the BC method, and two used the PRP method. Four WB units were pooled and split; 1 unit was processed less than 8 hours from collection (Group A), and the other three (Groups B, C, and D) were held at room temperature and processed after 24 to 26 hours. RBCs in Groups A and B were resuspended in saline-adenine-glucose-mannitol, Group C in phosphate-adenine-guanosine-glucose-saline-mannitol, and Group D in ErythroSol-4 RBCs were stored at 2 to 6°C for 49 days. RESULTS RBCs from overnight-held WB had lower 2,3-diphosphoglycerate (2,3-DPG) and higher adenosine triphosphate (ATP). At the end of storage there were no differences between groups, apart from a slightly higher hemolysis in Group B. ErythroSol-4 showed a slightly higher initial ATP and 2,3-DPG content, but at the end of storage no differences were found. CONCLUSION Overnight hold of WB before processing has no lasting deleterious effects on in vitro quality of subsequently prepared components. The use of different RBC ASs did not appear to offer significant advantages in terms of RBC quality at the end, regardless of the processing method.
Collapse
Affiliation(s)
- Pieter F van der Meer
- Department of Product and Process Development, Sanquin Blood Bank North West Region, Amsterdam, the Netherlands.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Shinar E, Etlin S, Frenkel O, Yahalom V. The implementation of rapid cooling and overnight hold of whole blood at ambient temperature before processing into components in Israel. Transfusion 2011; 51 Suppl 1:58S-64S. [DOI: 10.1111/j.1537-2995.2010.02964.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
18
|
Fischer JC, Quenzel EM, Moog R, Wenzel F, Riethmacher R, Tutschek B, Giers G. Reducing costs in flow-cytometric counting of residual white blood cells in blood products: utilization of a single-platform bead-free flow-rate calibration method. Transfusion 2011; 51:1431-8. [PMID: 21214578 DOI: 10.1111/j.1537-2995.2010.02998.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Commercial flow-cytometric methods for counting residual white blood cells (rWBCs) in leukoreduced blood products use calibration beads for estimation of the measured sample volume. A bead-free flow-rate calibration method is developed and validated. STUDY DESIGN AND METHODS The analyzed volume was calculated by acquisition time (ACQ). Twenty-nine spiking series of red blood cell (RBC) or platelet (PLT) products were prepared containing levels ranging from 0.08 × 10(6) up to 2048 × 10(6) WBCs/L. Nearly WBC-free triple-leukofiltered RBCs or PLT concentrates (PCs) served as background. Propidium iodide (PI) was used to identify rWBCs. Five RBC series were compared against a commercially available kit (LeukoSure, Beckman Coulter). Routine capabilities were tested on 41 RBC and 92 PC samples of two independent transfusion services. RESULTS The lower detection limit in RBC was 0.08 × 10(6) rWBCs/L for ACQ and 0.16 for LeukoSure. Criteria for linearity, accuracy, and precision were fulfilled within the range of 0.5 × 10(6) to 512 × 10(6) WBCs/L. For PCs, all these criteria were fulfilled between 0.5 × 10(6) and 32 × 10(6) rWBCs/L (lower detection limit of 0.25) for PI. ACQ and LeukoSure agreed sufficiently (81%) when tested on routine RBCs or PCs. CONCLUSION A residual WBC count of fewer than 0.5 × 10(6) WBCs/L can be accurately counted using the ACQ approach at a total reagent cost of less than 0.5€ per sample.
Collapse
Affiliation(s)
- Johannes C Fischer
- Institute for Transplantation Diagnostics and Cell Therapy, University of Duesseldorf, Duesseldorf, Germany.
| | | | | | | | | | | | | |
Collapse
|
19
|
Sandgren P, van Waeg G, Verheggen C, Sjödin A, Gulliksson H. Storage of interim platelet units for 18 to 24 hours before pooling: in vitro study. Transfusion 2010; 51:1213-9. [DOI: 10.1111/j.1537-2995.2010.02978.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
20
|
Peng TC, Hsu BG, Yang FL, Chao YFC, Harn HJ, Lee RP. Stability of Blood Biochemistry Levels in Animal Model Research: Effects of Storage Condition and Time. Biol Res Nurs 2009; 11:395-400. [DOI: 10.1177/1099800409350771] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
The purpose of this study was to compare whole blood and plasma in terms of the subsequent accuracy of blood lactate, glucose, lactate dehydrogenase (LDH), creatine phosphokinase (CPK), aspartate aminotransferase (AST), and alanine aminotransferase (ALT) measurement. Blood samples were drawn from 8 male Wistar-Kyoto rats. The rats were homologous, weighed 300— 380 g, were housed in the same environment, and were provided with food and water under the same conditions. Blood draws occurred in all rats at same time. The blood specimens were divided into two samples, one to be stored as whole blood (WBS) and one to be stored as plasma (PS). All the blood sample analyses were performed by trained and experienced personnel to ensure that differences in results were due to variation in form in which specimens were stored rather than to technique. The lactate concentration in the WBS group gradually increased over time, intraclass correlation coefficient (ICC) = 0.541, 95% confidence interval (CI; —0.197, 0.893), and was higher than that of the PS group, ICC = 0.897, 95% CI (0.733, 0.976). By contrast, glucose level gradually declined for the WBS group, ICC= —0.367, 95% CI (—2.563, 0.682). Whole blood storage increased measurement variation for lactate, glucose, LDH, and CPK. Plasma storage prolonged the stability of the biochemical components. This study demonstrates the importance of evaluating validity at each stage of developing and testing animal models.
Collapse
Affiliation(s)
- Tai-Chu Peng
- Department of Nursing, Tzu Chi College of Technology,
Hualien, Taiwan
| | - Bang-Gee Hsu
- Department of Nephrology, Buddhist Tzu Chi General Hospital,
Hualien, Taiwan
| | - Fwu-Lin Yang
- Division of Surgery, Critical Care Unit, Buddhist Tzu
Chi General Hospital, Hualien, Taiwan
| | | | - Horng-Jyh Harn
- Pathology Department, China Medical University Hospital,
Taichung, Taiwan
| | - Ru-Ping Lee
- Department of Nursing, Tzu Chi University, Hualien,
Taiwan,
| |
Collapse
|
21
|
Storage of whole blood overnight in different blood bags preceding preparation of blood components: in vitro effects on red blood cells. BLOOD TRANSFUSION = TRASFUSIONE DEL SANGUE 2009; 7:210-5. [PMID: 19657485 DOI: 10.2450/2009.0074-08] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 11/19/2008] [Accepted: 03/19/2009] [Indexed: 11/21/2022]
Abstract
BACKGROUND Routines for the storage of whole blood (WB) overnight for the preparation of blood components on the following day are of increasing interest primarily for logistic reasons. The present study focuses on in vitro effects during storage for 6 weeks on red blood cells (RBC) prepared in different blood containers after being held overnight. STUDY DESIGN AND METHODS Five different blood collection systems were used with either inline leucocyte reduction red cell filters for the preparation of RBC, buffy coat (BC) and plasma or WB filters for the preparation of RBC and plasma. A new container with an integrated WB filter removing leucocytes but not platelets was also included for the preparation of leucocyte-reduced RBC, BC and plasma units. Standard CPD solution (63 or 70 mL) and SAG-M solution (100 or 110 mL) were used for the collection of either 450 or 500 mL blood. All WB units were stored at room temperature, either overnight for 18-24 hours (test groups, n=104) or for up to 8 hours (reference groups, n=20). In addition, five test units were stored overnight under refrigeration. RESULTS In test groups (overnight storage at room temperature) we found significantly lower levels of extracellular potassium, 2,3-DPG and pH (up to day 28). During storage, higher levels of ATP (Terumo, CaridianBCT until day 35, Fresenius until day 14, Fenwal throughout storage) were seen in test groups than in reference groups. When WB was stored overnight at 2-6 degrees C before WB filtration, the levels of ATP and haemolysis were higher than in the corresponding reference. CONCLUSION Significant differences in in vitro parameters were observed between RBC prepared within 8 hours and 18-24 hours after blood collection. The results were consistent irrespective of the blood container used. New alkaline solutions may decrease the differences.
Collapse
|
22
|
Thomas S, Beard M, Garwood M, Callaert M, Cardigan R. Platelet concentrates produced from whole blood using the Atreus processing system. Vox Sang 2009; 97:93-101. [DOI: 10.1111/j.1423-0410.2009.01189.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
23
|
Gulliksson H, Vesterinen M, Payrat JM, Mayaudon V. Extended storage of whole blood before the preparation of blood components:in vitroeffects on red blood cells in Erythro-Sol environment. Vox Sang 2009; 96:199-205. [DOI: 10.1111/j.1423-0410.2008.01152.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
24
|
Thomas S, Beard M, Garwood M, Callaert M, Waeg GV, Cardigan R. Blood components produced from whole blood using the Atreus processing system. Transfusion 2008; 48:2515-24. [DOI: 10.1111/j.1537-2995.2008.01911.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
25
|
Thibault L, Beauséjour A, Jacques A, de Grandmont MJ, Lemieux R, Grégoire Y, Ducas É, Boucher G. Improved leucoreduction of red blood cell units prepared after a 24-h hold with the platelet-rich plasma method using newly developed filters. Vox Sang 2008; 94:286-91. [DOI: 10.1111/j.1423-0410.2007.01032.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
26
|
Dijkstra-Tiekstra MJ, Kuipers W, Setroikromo AC, de Wildt-Eggen J. Overnight or fresh buffy coat–derived platelet concentrates prepared with various platelet pooling systems. Transfusion 2008; 48:723-30. [DOI: 10.1111/j.1537-2995.2007.01611.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
27
|
Abstract
BACKGROUND In field emergency medicine, fresh whole-blood units are stored at room temperature up to 24 hours or occasionally longer. Few data exist on the integrity and in vitro functional properties of whole blood stored warm beyond 24 hours. STUDY DESIGN AND METHODS Ten citrate phosphate dextrose solution whole-blood units were collected and divided into two equal volumes. One-half of each unit was stored at 19 degrees C and the other half was stored at 25 degrees C, encompassing the accepted range for room temperature storage. At 6, 24, 48, and 72 hours, aliquots were collected from each unit and whole blood analyzed for cell counts, gases, and clotting function with thromboelastography, red cells for intracellular analytes, platelet (PLT)-rich plasma for aggregometry, and the supernatant for hemoglobin, potassium, glucose, lactate, and plasma clotting studies. RESULTS Whole-blood units stored at room temperature maintained cellular counts and coagulation activity for up to 72 hours. Units stored at 19 degrees C demonstrated greater RBC adenosine triphosphate and 2,3-diphosphoglycerate (DPG) content and stronger responses in PLT aggregation studies when compared with 25 degrees C storage. No significant hemolysis was observed, and no bacterial growth was detected. CONCLUSION Storage of whole blood at room temperature for 72 hours leads to marked reductions in pH and DPG, but the observed reduction in PLT function and plasma coagulation factor activity was surprisingly modest compared to literature values. These findings should prompt additional investigation, given their potential importance for whole blood processing and field-expedient transfusion.
Collapse
Affiliation(s)
- J D Hughes
- Blood Bank Fellowship, Walter Reed Army Medical Center, Washington, DC, USA
| | | | | |
Collapse
|
28
|
van der Meer PF, Pietersz RNI. Overnight storage of whole blood: a comparison of two designs of butane-1,4-diol cooling plates. Transfusion 2008; 47:2038-43. [PMID: 17958532 DOI: 10.1111/j.1537-2995.2007.01427.x] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Whole blood (WB) can be stored overnight before processing, provided that it is quickly cooled to room temperature (20-25 degrees C), for example, with butane-1,4-diol plates. A new design of cooling plates became available (CompoCool-WB, Fresenius HemoCare), where WB must be placed vertically against the plates, versus placing of WB under plates in the current version (Compocool). This study compared cooling efficiency and in vitro quality of plasma and of stored white cell (WBC)-reduced red cells (RBCs) from overnight-stored WB, cooled with either of the systems. STUDY DESIGN AND METHODS Temperature curves following cooling with Compocool or CompoCool-WB were studied with a 25 percent glycerol solution as simulated WB. WB from voluntary donors was cooled with Compocool or CompoCool-WB, stored overnight at room temperature, centrifuged, and separated into components. WBC-reduced RBCs in SAGM were stored until Day 42 with measurement of in vitro parameters (n=23/group). RESULTS Simulated WB reached a temperature of less than 25 degrees C after 2:15+/-1:04 hours for Compocool versus 1:39+/-0:38 hours for CompoCool-WB (p=0.02). On Day 35, RBCs had a hemolysis of 0.3+/-0.2 percent in both groups, and ATP levels were 3.3+/-0.5 and 3.6+/-0.5 micromol per g hemoglobin for Compocool and CompoCool-WB, respectively (not significant). Factor VIII content in plasma was 1.05+/-0.25 and 0.97+/-0.18 IU per mL for Compocool and CompoCool-WB, respectively. CONCLUSION WB can be cooled to room temperature within 2 hours with both Compocool and CompoCool-WB butane-1,4-diol plates, improving temperature uniformity in WB donations. Application of either design for overnight storage of WB at room temperature had no adverse effects on the composition of subsequently prepared blood components.
Collapse
|
29
|
Palmer DS, Birch P, O'Toole J, Henderson D, Scalia V. Flow cytometric determination of residual white blood cell levels in preserved samples from leukoreduced blood products. Transfusion 2008; 48:118-28. [PMID: 17900282 DOI: 10.1111/j.1537-2995.2007.01489.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND In preparation for a proposed consolidated testing service, Canadian Blood Services undertook the evaluation of a commercial test kit for the enumeration by flow cytometry of residual white blood cells (rWBCs) present in preserved samples recovered from leukoreduced (LR) blood and platelet products. STUDY DESIGN AND METHODS The stability of preserved WBCs, the equivalency of WBCs used for spiking, test method precision, specificity, reliability, accuracy, and sensitivity were investigated. For comparative purposes, WBC counts were also determined by Nageotte as well as by flow cytometry. RESULTS WBCs were stable up to 4 weeks at room temperature for all components by either method. Within methods, no differences were observed due to the source of WBC used for spiking purposes. By either method, test precision was acceptable (<20% coefficient of variation) and of similar reliability at a target value of 10 +/- 5 WBCs per microL. The flow cytometric method was shown to be more specific and accurate than the Nageotte method. Sensitivity by either method was 0.1 WBCs per microL. On average, Nageotte counts were lower than those observed by flow cytometry. CONCLUSIONS These results demonstrate that WBCs in WBC stabilizing solution-treated samples from LR blood components were stabilized up to 4 weeks at room temperature and that rWBC determinations made with a WBC enumeration kit by flow cytometry have the required precision, specificity, reliability, and accuracy in the relevant test range. This validated WBC stabilization and flow cytometric counting method is considered acceptable as part of a quality control program for leukoreduced blood products.
Collapse
Affiliation(s)
- Douglas S Palmer
- Canadian Blood Services, National Testing Laboratory, Ottawa, Ontario, Canada.
| | | | | | | | | |
Collapse
|
30
|
Cid J, Claparols M, Pinacho A, Hernández JM, Ortiz P, Puig LS, Pla RP. Comparison of blood component preparation methods from whole blood bags based on buffy coat extraction. Transfus Apher Sci 2007; 36:243-7. [PMID: 17569593 DOI: 10.1016/j.transci.2006.11.003] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2006] [Revised: 11/17/2006] [Accepted: 11/20/2006] [Indexed: 10/23/2022]
Abstract
We compared the data of our quality control laboratory of the blood components according to the blood component preparation method that we used. We prepared blood components from top and top whole blood (WB) bags and manual pooling of buffy coats (BCs) (method I) or from top and bottom WB bags and automated pooling of BCs with OrbiSac (method II). Pooled platelet concentrates (PC) obtained with method II had higher platelet content when compared with pooled PCs obtained with method I (3.5+/-0.7x10(11) vs. 2.6+/-0.8x10(11); p<0.001). The hemoglobin content in the RBCs obtained with method I was higher when compared with method II (55+/-7g vs. 52.5+/-6.6g; p<0.001).
Collapse
Affiliation(s)
- Joan Cid
- Banc de Sang i Teixits, Passeig Vall d'Hebron, 119-129, 08035 Barcelona, Spain.
| | | | | | | | | | | | | |
Collapse
|