Anand G, Yu Y, Lowe A, Kalra A. Bioimpedance analysis as a tool for hemodynamic monitoring: overview, methods and challenges. Physiol Meas 2021; 42. [PMID: 33607637 DOI: 10.1088/1361-6579/abe80e] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Accepted: 02/19/2021] [Indexed: 12/14/2022]
Abstract
Recent advances in hemodynamic monitoring have seen the advent of non-invasive methods which offer ease of application and improve patient comfort. Bioimpedance Analysis or BIA is one of the currently employed non-invasive techniques for hemodynamic monitoring. Impedance Cardiography (ICG), one of the implementations of BIA, is widely used as a non-invasive procedure for estimating hemodynamic parameters such as stroke volume (SV) and cardiac output (CO). Even though BIA is not a new diagnostic technique, it has failed to gain consensus as a reliable measure of hemodynamic parameters. Several devices have emerged for estimating CO using ICG which are based on evolving methodologies and techniques to calculate SV. However, the calculations are generally dependent on the electrode configurations (whole body, segmental or localised) as well as the accuracy of different techniques in tracking blood flow changes. Blood volume changes, concentration of red blood cells, pulsatile velocity profile and ambient temperature contribute to the overall conductivity of blood and hence its impedance response during flow. There is a growing interest in investigating limbs for localised BIA to estimate hemodynamic parameters such as pulse wave velocity. As such, this paper summarises the current state of hemodynamic monitoring through BIA in terms of different configurations and devices in the market. The conductivity of blood flow has been emphasized with contributions from both volume and velocity changes during flow. Recommendations for using BIA in hemodynamic monitoring have been mentioned highlighting the suitable range of frequencies (1 kHz-1 MHz) as well as safety considerations for a BIA setup. Finally, current challenges in using BIA such as geometry assumption and inaccuracies have been discussed while mentioning potential advantages of a multi-frequency analysis to cover all the major contributors to blood's impedance response during flow.
Collapse
Affiliation(s)
- Gautam Anand
- Institute of Biomedical Technologies, Auckland University of Technology, Auckland, New Zealand
| | - Yang Yu
- Institute of Biomedical Technologies, Auckland University of Technology, Auckland, New Zealand
| | - Andrew Lowe
- Institute of Biomedical Technologies, Auckland University of Technology, Auckland, New Zealand
| | - Anubha Kalra
- Institute of Biomedical Technologies, Auckland University of Technology, Auckland, New Zealand
| |
Collapse
|
2
|
Ogawa K, Igarashi M, Nogami A, Yamamoto M, Sugano A, Sekiguchi Y, Aonuma K, Ieda M. The Usefulness and Limitations of Impedance Cardiography for Cardiac Resynchronization Therapy Device Optimization. Int Heart J 2020; 61:896-904. [PMID: 32999195 DOI: 10.1536/ihj.19-620] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Identifying the optimal atrioventricular (AV) or interventricular (VV) delay is beneficial for patients using cardiac resynchronization therapy (CRT) devices. Ultrasonic echocardiography (UCG) has been the most commonly used method; however, it requires high technical knowledge. Impedance cardiography (ICG) can calculate stroke volume by measuring changes in transthoracic electric impedance. This study sought to assess the clinical utility of ICG in comparison with that of UCG for the optimization of CRT devices.Patients who underwent CRT device implantation were retrospectively analyzed. One week after implantation, optimization of AV delay (AVD) was performed in every patient with ICG (AVD-ICG) and UCG (AVD-UCG). VV delay (VVD) was then determined according to the optimal AVD using these two methods.Forty-two patients were enrolled. Average AVD-ICG was significantly shorter than AVD-UCG (128 ± 49 versus 146 ± 41 milliseconds, P = 0.018). Five patients (12%) had the same optimized AVD with two methods, and the difference between AVD-ICG and AVD-UCG was ≤ 20 milliseconds in 19 patients (45%). In the multivariate analysis, the presence of postoperative mitral regurgitation (MR) was an independent predictor of AVD-ICG/AVD-UCG mismatch, defined as a difference over 20 milliseconds (odds ratio = 10.71; 95% confidence interval = 1.72 to 66.72; P = 0.018). The results of optimized VVD were similar using both methods.ICG might be a promising tool for the rapid optimization of CRT devices. However, in patients with moderate-to-severe MR, ICG may not be able to optimize AVD.
Collapse
Affiliation(s)
- Kojiro Ogawa
- Department of Cardiology, Faculty of Medicine, University of Tsukuba.,Department of Cardiology, Hitachi General Hospital
| | - Miyako Igarashi
- Department of Cardiology, Faculty of Medicine, University of Tsukuba
| | - Akihiko Nogami
- Department of Cardiology, Faculty of Medicine, University of Tsukuba
| | | | - Akinori Sugano
- Department of Cardiology, Faculty of Medicine, University of Tsukuba.,Department of Cardiology, Tsukuba Medical Center Hospital
| | - Yukio Sekiguchi
- Department of Cardiology, Faculty of Medicine, University of Tsukuba.,Department of Internal Medicine (Cardiology), Kasumigaura Medical Center
| | - Kazutaka Aonuma
- Department of Cardiology, Faculty of Medicine, University of Tsukuba
| | - Masaki Ieda
- Department of Cardiology, Faculty of Medicine, University of Tsukuba
| |
Collapse
|
3
|
Urbanek B, Kaczmarek K, Klimczak A, Ruta J, Chudzik M, Piestrzeniewicz K, Ptaszynski P, Wranicz JK. Potential benefit of optimizing atrioventricular & interventricular delays in patients with cardiac resynchronization therapy. Indian J Med Res 2018; 146:71-77. [PMID: 29168462 PMCID: PMC5719610 DOI: 10.4103/ijmr.ijmr_1560_14] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Background & objectives: The clinical benefit of optimization (OPT) of atrioventricular delay (AVD) and interventricular delay (VVD) in cardiac resynchronization therapy (CRT) remains debatable. This study was aimed to determine the influence of AVD and VVD OPT on selected parameters in patients early after CRT implantation and at mid-term follow up (FU). Methods: Fifty two patients (61±10 yr, 23 males) with left bundle branch block, left ventricular ejection fraction (LVEF) ≤35 per cent and heart failure were selected for CRT implantation. Early on the second day (2DFU) after CRT implantation, the patients were assigned to the OPT or the factory setting (FS) group. Haemodynamic and electrical parameters were evaluated at baseline, on 2DFU after CRT and mid-term FU [three-month FU (3MFU)]. Echocardiographic measures were assessed before implantation and at 3MFU. The AVD/VVD was deemed optimal for the highest cardiac output (CO) with impedance cardiography (ICG) monitoring. Results: On 2DFU, the AVD was shorter in the OPT group, LV was paced earlier than in FS group and CO was insignificantly higher in OPT group. At 3MFU, improvement of CO was observed only in OPT patients, but the intergroup difference was not significant. At 3MFU in OPT group, reduction of LV in terms of LV end-diastolic diameter (LVeDD), LV end-systolic diameter, LV end-diastolic and systolic volume with the improvement in LVEF was observed. In FS group, only a reduction in LVeDD was present. In OPT group, the paced QRS duration was shorter than in FS group patients. Interpretation & conclusions: CRT OPT of AVD and VVD with ICG was associated with a higher CO and better reverse LV remodelling. CO monitoring with ICG is a simple, non-invasive tool to optimize CRT devices.
Collapse
Affiliation(s)
- Bozena Urbanek
- Department of Electrocardiology, Medical University of Lodz, Lodz, Poland
| | | | - Artur Klimczak
- Department of Electrocardiology, Medical University of Lodz, Lodz, Poland
| | - Jan Ruta
- Department of Electrocardiology, Medical University of Lodz, Lodz, Poland
| | - Michal Chudzik
- Department of Electrocardiology, Medical University of Lodz, Lodz, Poland
| | | | - Pawel Ptaszynski
- Department of Electrocardiology, Medical University of Lodz, Lodz, Poland
| | | |
Collapse
|
4
|
Daralammouri Y, Ayoub K, Badrieh N, Lauer B. A hybrid approach for quantifying aortic valve stenosis using impedance cardiography and echocardiography. BMC Cardiovasc Disord 2016; 16:19. [PMID: 26800673 PMCID: PMC4722721 DOI: 10.1186/s12872-015-0155-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2015] [Accepted: 11/20/2015] [Indexed: 11/10/2022] Open
Abstract
Background Methods Results Conclusion
Collapse
|
5
|
Krychtiuk KA, Nürnberg M, Volker R, Pachinger L, Jarai R, Freynhofer MK, Wojta J, Huber K, Weiss TW. Effects of AV-delay optimization on hemodynamic parameters in patients with VDD pacemakers. Wien Klin Wochenschr 2014; 126:270-7. [PMID: 24652015 DOI: 10.1007/s00508-014-0520-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2013] [Accepted: 02/04/2014] [Indexed: 02/05/2023]
Abstract
AIM Atrioventricular (AV) delay optimization improves hemodynamics and clinical parameters in patients treated with cardiac resynchronization therapy and dual-chamber-pacemakers (PM). However, data on optimizing AV delay in patients treated with VDD-PMs are scarce. We, therefore, investigated the acute and chronic effects of AV delay optimization on hemodynamics in patients treated with VDD-PMs due to AV-conduction disturbances. METHODS In this prospective, single-center interventional trial, we included 64 patients (38 men, 26 women, median age: 77 (70-82) years) with implanted VDD-PM. AV-delay optimization was performed using a formula based on the surface electrocardiogram (ECG). Hemodynamic parameters (stroke volume (SV), cardiac output (CO), heart rate (HR), and blood pressure (BP)) were measured at baseline and follow-up after 3 months using impedance cardiography. RESULTS Using an ECG formula for AV-delay optimization, the AV interval was decreased from 180 (180-180) to 75 (75-100) ms. At baseline, AV-delay optimization led to a significant increase of both SV (71.3 ± 15.8 vs. 55.3 ± 12.7 ml, p < 0.001, for optimized AV delay vs. nominal AV interval, respectively) and CO (5.1 ± 1.4 vs. 3.9 ± 1.0 l/min, p < 0.001), while HR and BP remained unchanged. At follow-up, the improvement in CO remained stable (4.9 ± 1.3 l/min, p = 0.09), while SV slightly, but significantly, decreased (to 65.1 ± 17.6, p < 0.01). CONCLUSION AV-delay optimization in patients treated with VDD-PMs exhibits immediate beneficial effects on hemodynamic parameters that are sustained for 3 months.
Collapse
Affiliation(s)
- Konstantin A Krychtiuk
- Department of Internal Medicine II-Division of Cardiology, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria,
| | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Klimczak A, Budzikowski AS, Rosiak M, Zielińska M, Urbanek B, Bartczak K, Chudzik M, Wranicz JK. Influence of atrioventricular optimization on hemodynamic parameters and quality of life in patients with dual chamber pacemaker with ventricular lead in right ventricular outflow tract. Ann Noninvasive Electrocardiol 2014; 19:471-6. [PMID: 24597906 DOI: 10.1111/anec.12147] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
BACKGROUND The aim of this study was to ascertain whether individual atrioventricular delay (AVD) optimization using impedance cardiography (ICG) offers beneficial hemodynamic effects as well as improved exercise tolerance and quality of life in patients with requiring constant right ventricular pacing. METHODS There were 37 patients with advanced AV block included in the study. Several examinations were performed at the beginning. Next, the optimization of AVD by ICG was done. The next step of the study patients have been randomized into optimal AVD group (AVDopt) or factory setting group (AVDfab). After 3 months, the follow-up all data were collected again and crossover was performed. After another 3 months, during the final follow-up all these measures were repeated. RESULTS In 87.5% patients, AVDopt were different than factory value. Cardiac output (CO), cardiac index (CI), and stroke volume (SV) were significantly (P < 0.001) higher in AVDopt group than in AVDfab group (CO: 6.0 ± 1.4 L/minute vs. 5.3 ± 1.2 L/minute; SV: 85.8 ± 25.7 mL vs.76.9 ± 22.5 mL; CI: 3.2 ± 0.7 L/minute/m(2) vs. 2.7 ± 0.6 L/minute/m(2) ). There was a statistical significant (P < 0.05) reduction of proBNP and NYHA class in patients with AVDopt compared to AVDfab (proBNP: 196.4 ± 144.7pg/mL vs. 269.4 ± 235.8 pg/mL; NYHA class: 1.7 ± 0.5 vs. 2.3 ± 0.6). Six-minute walking test was significantly (P < 0.05) higher in AVDopt group (409 ± 90 m) than in AVDfab group (362 ± 93 m). There were no statistically significant differences in echocardiographic parameters between AVDopt and AVDfab settings. CONCLUSION Our study results suggest that AVD optimization in patients with DDD pacemaker with ICG improves hemodynamic when compared to the default factory settings. Furthermore, optimally programmed AVD reduces BNP and improves exercise tolerance and functional class.
Collapse
Affiliation(s)
- Artur Klimczak
- Department of Electrocardiology, Medical University of Lodz, Lodz, Poland
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Prochnau D, Forberg T, Kühnert H, Heinke M, Figulla HR, Surber R. Optimization of the atrioventricular delay during cardiac resynchronization therapy using a device for non-invasive measurement of cardiac index at rest and during exercise. Europace 2011; 14:249-53. [PMID: 21933798 DOI: 10.1093/europace/eur296] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
AIMS It is not clear whether cardiac resynchronization therapy (CRT) should only be optimized at rest or whether it is necessary to perform CRT optimization during exercise. Our study aims to answer this question by using an inert gas rebreathing method (Innocor®). METHODS AND RESULTS Twenty-seven patients with congestive heart failure and implanted CRT devices were included in the study. The aetiology of the heart failure was ischaemic in nine (33%) patients. Patients had low left ventricular ejection fraction (29 ± 8%) and enlarged LV end-diastolic diameters (63 ± 7 mm). Atrioventricular delay (AVD) was optimized at rest according to cardiac index (CI), measured by inert gas rebreathing (Innocor®). Thereafter, patients performed standardized, steady-state bicycle exercise at 30 W in sitting body position. Three AVDs were tested during exercise in a random sequence: optimized resting AVD (AVD(opt)) according to baseline measurement; AVD(opt) - 30 ms; and AVD(opt) + 30 ms. Cardiac index was measured in each AVD by inert gas rebreathing. Cardiac index increased significantly during exercise. However, neither AVD(opt) shortening nor prolongation during exercise had significant effect on CI (shortening of AVD(opt) - 30 ms was accompanied by a reduction of CI of 4.8%, prolongation of AVD(opt) + 30 ms was accompanied by a reduction of CI of 7.7%). CONCLUSION Shortening or lengthening of the AVD during exercise has no impact on CI in CRT patients. On the basis of our results, we conclude that in CRT patients the AVD should be programmed, fixed even during exercise.
Collapse
Affiliation(s)
- Dirk Prochnau
- Department of Internal Medicine I, Friedrich Schiller University, Erlanger Allee 101, 07747 Jena, Germany
| | | | | | | | | | | |
Collapse
|
8
|
Klimczak A, Chudzik M, Zielińska M, Budzikowski AS, Lewek J, K.Wranicz J. Optimization of atrio-ventricular delay in patients with dual-chamber pacemaker. Int J Cardiol 2010; 141:222-6. [DOI: 10.1016/j.ijcard.2009.10.021] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2009] [Accepted: 10/18/2009] [Indexed: 10/20/2022]
|
9
|
Maines M, Landolina M, Lunati M, Lonardi G, Pappone A, Proclemer A, Zanotto G, Santini M, Varbaro A, Vimercati M, Valsecchi S. Intrathoracic and ventricular impedances are associated with changes in ventricular volume in patients receiving defibrillators for CRT. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2009; 33:64-73. [PMID: 19821939 DOI: 10.1111/j.1540-8159.2009.02579.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Some implantable cardioverter defibrillators (ICD) are able to monitor intrathoracic impedance to detect pulmonary fluid overload. This is achieved by measuring impedance between the ICD case and the right ventricular (RV) lead. We hypothesized that the measured impedance would rise with improvement in left ventricular (LV) volumes during cardiac resynchronization therapy (CRT), and that such impedance changes would be more apparent when measured with an alternative pacing vector. METHODS We analyzed echocardiographic and impedance data from heart failure patients implanted with a CRT-ICD capable of intrathoracic impedance measurement for fluid accumulation diagnosis, and LV pacing impedance recording for lead integrity monitoring. RESULTS In 127 out of 170 patients that received de novo CRT implantation, the LV end-systolic volume (LVESV) decreased at 6-month follow-up (LVESV at 6 month-LVESV at baseline <0: group A). For the remaining 43 patients (group B) the change was > or = 0. Despite comparable values at baseline (P = 0.262), the impedances of groups A and B gradually diverged soon after the implant, resulting in significant difference between the two groups at the 6-month visit (P = 0.001). The changes in LV dimensions produced larger differences between groups in the impedance measured between the LV and the RV leads (P < 0.001). The regression analysis demonstrated an inverse correlation between paired changes of volume and intrathoracic impedance. Higher correlation coefficient was obtained using the LV-to-RV measurement vector (r =-0.635, P < 0.001). CONCLUSIONS The changes in ICD-measured impedance seem associated with the LV volume changes induced by CRT. Specifically, the LV-to-RV impedance estimations seem to better correlate with paired changes of ventricular volumes.
Collapse
Affiliation(s)
- Massimiliano Maines
- Division of Cardiology, Santa Maria del Carmine Hospital, Corso Verona, 4, 38068 Rovereto (TN), Italy.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
TSURUGI TAKUO, ABE HARUHIKO, OGINOSAWA YASUSHI, KOHNO RITSUKO, YASUMASU TOMIYA, NAGATOMO TOSHIHISA, OTSUJI YUTAKA. Effects of Pacing Modes on Cardiac Baroreflex Function in Permanently Paced Patients with Sinus Node Dysfunction. J Cardiovasc Electrophysiol 2008; 19:702-7. [DOI: 10.1111/j.1540-8167.2008.01109.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
11
|
Heinke M, Surber R, Kühnert H, Dannberg G, Prochnau D, Figulla HR. Transesophageal left ventricular posterior wall potential in heart failure patients with biventricular pacing / Transösophageales linksventrikuläres Potenzial der posterioren Wand bei Patienten mit Herzinsuffizienz und biventrikulärer Stimulation. BIOMED ENG-BIOMED TE 2007; 52:173-9. [PMID: 17408376 DOI: 10.1515/bmt.2007.033] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
INTRODUCTION Biventricular (BV) pacing is an established therapy for heart failure (HF) patients with intraventricular conduction delay, but not all patients improved clinically. We investigated the interventricular delay (IVD) by means of the transesophageal left ventricular posterior wall potential (LVPWP). MATERIALS AND METHODS, AND RESULTS A total of 18 HF patients (age 62+/-9 years; 15 males) with NYHA class 3.1+/-0.3, LV ejection fraction 22+/-7%, left bundle branch block and a QRS duration (QRSD) of 171+/-27 ms were analyzed using transesophageal LVPWP before implantation of a BV pacing device. The median follow up was 14+/-14 months. In 14 responders, IVD was 81+/-25 ms with a QRSD/IVD ratio of 2.2+/-0.3 with reclassification of NYHA class 3.1+/-0.3 to 2.0+/-0.5 (p<0.001) and an increase in LV ejection fraction from 22+/-7% to 36+/-11% (p=0.001) during long-term BV pacing. In four non-responders, transesophageal IVD was significantly smaller at 30+/-11 ms (p=0.001). CONCLUSION Transesophageal IVD may be a useful method to detect responders to BV pacing. Transesophageal LVPWP may be a simple and useful technique to detect clinical responders to BV pacing in HF patients.
Collapse
Affiliation(s)
- Matthias Heinke
- Department of Internal Medicine I, Cardiology Division, Friedrich Schiller University Jena, Jena, Germany.
| | | | | | | | | | | |
Collapse
|
12
|
Ovsyshcher IE. The search for optimal atrioventricular interval. J Interv Card Electrophysiol 2005; 14:95-8. [PMID: 16374556 DOI: 10.1007/s10840-005-4514-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2005] [Accepted: 08/22/2005] [Indexed: 01/01/2023]
Affiliation(s)
- I Eli Ovsyshcher
- Electrophysiology, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel.
| |
Collapse
|
13
|
Abstract
The study's goal was to determine if cardiac output (CO), obtained by impedance cardiography (ICG), would be improved by a new equation N, implementing a square root transformation for dZ/dtmax/Z0, and a variable magnitude, mass-based volume conductor Vc. Pulmonary artery catheterisation was performed on 106 cardiac surgery patients pre-operatively. Post-operatively, thermodilution cardiac output (TDCO) was simultaneously compared with ICG CO. dZ/dtmax/Z0 and Z0 were obtained from a proprietary bioimpedance device. The impedance variables, in addition to left ventricular ejection time TLVE and patient height and weight, were input using four stroke volume (SV) equations: Kubicek (K), Sramek (S), Sramek-Bernstein (SB), and a new equation N. CO was calculated as SV x heart rate. Data are presented as mean +/- SD. One way repeated measures of ANOVA followed by the Tukey test were used for inter-group comparisons. Bland-Altman methods were used to assess bias, precision and limits of agreement. P< 0.05 was considered statistically significant. CO implementing N (6.06 +/- 1.48 l min(-1)) was not different from TDCO (5.97 +/- 1.41 l min(-1)). By contrast, CO calculated using K (3.70 +/- 1.53 l min(-1)), S (4.16 +/- 1.83 l min(-1)) and SB (4.37 +/- 1.82 l min(-1)) was significantly less than TDCO. Bland-Altman analysis showed poor agreement between TDCO and K, S and SB, but not between TDCO and N. Compared with TDCO, equation N, using a square-root transformation for dZ/dtmax/Z0, and a mass-based Vc, was superior to existing transthoracic impedance techniques for SV and CO determination.
Collapse
Affiliation(s)
- D P Bernstein
- Department of Anesthesiology, Palomar Medical Center, Escondido, CA, USA.
| | | |
Collapse
|
14
|
Wilson M, Davis DP, Coimbra R. Diagnosis and monitoring of hemorrhagic shock during the initial resuscitation of multiple trauma patients: a review. J Emerg Med 2003; 24:413-22. [PMID: 12745044 DOI: 10.1016/s0736-4679(03)00042-8] [Citation(s) in RCA: 126] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The initial management of the multiple trauma victim requires evaluation for potential hemorrhage and ongoing monitoring to assess the efficacy of resuscitation and avoid complications related to hemorrhagic shock. A variety of strategies exist to assess circulatory status, including hemodynamic monitoring, tissue perfusion measurement, and use of serum markers of metabolism. We review available technologies used to assess fluid status and tissue perfusion in patients with blood loss or hemorrhagic shock, discuss how these methods can be used effectively and efficiently during initial trauma resuscitation to guide therapy and disposition, and suggest directions for future research to improve outcomes by providing more appropriate and timely care and avoiding unnecessary complications.
Collapse
Affiliation(s)
- Michael Wilson
- Department of Emergency Medicine, University of Arizona, Tucson, Arizona, USA
| | | | | |
Collapse
|
15
|
Perl S, Weitzman S, Battler A, Katz A. Absence of Increased Systemic Vascular Resistance During Syncopal Episodes in Patients with Tilt-Positive Neurocardiogenic Syncope. Ann Noninvasive Electrocardiol 1999. [DOI: 10.1111/j.1542-474x.1999.tb00050.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
16
|
Abstract
The aim of the study was to investigate pacing impedance (PI) behavior in ambulatory patients. Eighteen atrial and 18 ventricular tined steroid eluting leads with 1.2-mm2 and 5.6-mm2 electrodes were implanted in 20 patients. At 9-27 months after implantation PI was measured automatically by means of additional algorithms downloaded via telemetry links into implanted Thera pulse generators. PI was determined based on the voltage drop on the output capacitor during the 5 V-1 ms pacing impulse, at the programmable sampling rates from 1 second to 30 minutes. The study examined in particular: (1) PI trends and variations associated with different breathing patterns, body postures, provocative maneuvers, bike exercise, and during 24 hours; (2) impact of pacing rate and AV-delay on PI; (3) correlation between PI variability and pacing threshold, lead configuration, absolute PI value, age, gender, disease, and cardiac chamber. The most important findings were: (1) large PI variations of up to 450 omega were observed in properly functioning leads, (2) PI variability exhibited a weak negative correlation with pacing thresholds as if electrode positional stability was not a major factor underlying PI variations, (3) unipolar and bipolar PI variations were equivalent to each other (correlation factor = 0.93) implying that PI was mostly dependent on the circumstances around the lead tip.
Collapse
Affiliation(s)
- D Danilovic
- Medical Department A, Haukeland University Hospital, Bergen, Norway
| | | |
Collapse
|
17
|
Kindermann M, Fröhlig G, Doerr T, Schieffer H. Optimizing the AV delay in DDD pacemaker patients with high degree AV block: mitral valve Doppler versus impedance cardiography. Pacing Clin Electrophysiol 1997; 20:2453-62. [PMID: 9358487 DOI: 10.1111/j.1540-8159.1997.tb06085.x] [Citation(s) in RCA: 157] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
In DDD-pacemaker patients with high degree AV block, Doppler echocardiography of transmitral blood flow can be used to find the individually optimal AV delay (AVO) for left heart AV synchronization. This study tried to validate a Doppler method (ECHO) recently proposed to optimize left ventricular filling by comparing it to stroke volume data derived from impedance cardiography (ICG). It should be further elucidated if optimizing the AV delay (AVD) by means of this method is superior to fixed AVD settings and which differential AVD (pace-sense-offset) should be programmed for atrially triggered (ATP) and AV sequential (AVP) pacing, respectively. AVO as measured in 53 patients showed a linear correlation between ECHO and ICG for both ATP (r = 0.66, P < 0.00001) and AVP (r = 0.53; P < 0.005). The mean deviation in AVO between ECHO and ICG was +/- 26 ms (ATP) and +/- 30 ms (AVP), respectively, with a tendency to longer AVDs with the Doppler method. ECHO limitations could mainly be attributed to: (1) restrictions of AVD programming options (which may be compensated for by slight modification of the proposal); and (2) to pathophysiological mechanisms that alter mitral valve dynamics. Optimization of the AVD by Doppler produced a stroke volume that was significantly higher (19%) than with a fixed AVD (150 ms in ATP; 200 ms in AVP). There was a wide scatter in pace-sense-offsets between-7 and 134 ms, which was reflected by both methods. It is concluded that AVO determinations by ECHO are valid provided that methodological pitfalls and limitations caused by the disease are recognized. Tailoring AVD with respect to diastolic filling improves systolic function and is superior to nominal AVD settings. Fixed differential AVDs as offered by some manufacturers are far from being physiological. Thus modern pulse generators should offer free programmability over a wide range of AV delays.
Collapse
Affiliation(s)
- M Kindermann
- Universitätskliniken des Saarlandes, Homburg/Saar, Germany
| | | | | | | |
Collapse
|
18
|
Frielingsdorf J, Bertel O. LETTERS TO THE EDITOR. Pacing Clin Electrophysiol 1997. [DOI: 10.1111/j.1540-8159.1997.tb05511.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
19
|
Crystal E, Ovsyshcher IE. The assessment of atrioventricular (AV) delay and quality-of-life in DDD paced patients. Pacing Clin Electrophysiol 1997; 20:999-1001. [PMID: 9127412 DOI: 10.1111/j.1540-8159.1997.tb05510.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
20
|
Ovsyshcher IE. Toward physiological pacing: optimization of cardiac hemodynamics by AV delay adjustment. Pacing Clin Electrophysiol 1997; 20:861-5. [PMID: 9127389 DOI: 10.1111/j.1540-8159.1997.tb05487.x] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
21
|
Raaijmakers E, Faes TJ, Goovaerts HG, de Vries PM, Heethaar RM. The inaccuracy of Kubicek's one-cylinder model in thoracic impedance cardiography. IEEE Trans Biomed Eng 1997; 44:70-6. [PMID: 9214785 DOI: 10.1109/10.553714] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The validity of a one- and a two-cylinder model, underlying thoracic impedance cardiography (TIC), was investigated by studying the length dependence of the impedance parameters Z0, (dZ/dt)min, and stroke volume (SV). It can be shown that, within a one-cylinder model, all parameters are directly proportional to the length, whereas, if the volume conduction of the thorax and the neck are modeled separately, Z0 and (dZ/dt)min are expected to be linear dependent and SV will be nonlinear upon the length. The expectations were compared to results from in vivo measurements. Two electrode arrays were studied, in which the caudal recording electrode position was varied; SV was calculated using Kubicek's equation. Except for small distances, the results showed a nearly linear relation between the parameters and the length. Regression analysis of the linear part revealed statistically significant intercepts (p < 0.05). Neither the intercept nor the nonlinear part can be explained by a one-cylinder model, whereas a model consisting of two cylinders serially connected describes the experimental results accurately. Thus SV estimation based on a one-cylinder model is biased due to the invalid one-cylinder model. Corrections for the Kubicek-equation need to be developed in future research using this two-cylinder model.
Collapse
Affiliation(s)
- E Raaijmakers
- Department of Medical Physics and Informatics, Institute of Cardiovascular Diseases VU, University Hospital, Vrije Universiteit, Amsterdam, The Netherlands.
| | | | | | | | | |
Collapse
|
22
|
Lack of agreement between bioimpedance and continuous thermodilution measurement of cardiac output in intensive care unit patients. Crit Care 1997; 1:71-74. [PMID: 11056698 PMCID: PMC28990 DOI: 10.1186/cc106] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/1997] [Revised: 09/08/1997] [Accepted: 09/12/1997] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND: Bolus thermodilution is the standard bedside method of cardiac output measurement in the intensive care unit (ICU). The Baxter Vigilance monitor uses a modified thermodilution pulmonary artery catheter with a thermal filament to give a continuous read-out of cardiac output. This has been shown to correlate very well with both the 'gold standard' dye dilution method and the bolus thermodilution method. Bioimpedance cardiography using the Bomed NCCOM 3 offers a noninvasive means of continuous cardiac output measurement and has been shown to correlate with the bolus thermodilution method. We investigated the agreement between the continuous bioimpedance and continuous thermodilution methods, enabling acquisition of a large number of simultaneous measurements. RESULTS: A total of 2390 paired data points from seven patients were collected. There was no correlation (r2 = 0.01) between the methods. The precision (1.16 l/min/m2) of agreement between the Vigilance and the Bomed, assessed by the Bland-Altam method, was very poor although the bias (-0.16 l/min/m2) appeared fair. CONCLUSIONS: The Bomed NCCOM 3 bioimpedance monitor shows poor agreement with the Baxter Vigilance continuous thermodilution monitor in a group of general ICU patients and cannot be recommended for cardiac output monitoring in this situation.
Collapse
|
23
|
Scherhag AW, Pfleger S, de Mey C, Schreckenberger AB, Staedt U, Heene DL. Continuous measurement of hemodynamic alterations during pharmacologic cardiovascular stress using automated impedance cardiography. J Clin Pharmacol 1997; 37:21S-28S. [PMID: 9048281 DOI: 10.1177/009127009703700118] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The contribution of computerized impedance cardiography in monitoring and differentiating cardiovascular responses to pharmacologic stress after the administration of dipyridamole (group 1, n = 24) or dobutamine (group 2, n = 26) was investigated during stress echocardiography. Heart rate, stroke volume index, cardiac index and systemic vascular resistance index were evaluated continuously with an automated, computerized, signal-averaged impedance cardiography system. Dipyridamole had little average effect on heart rate, stroke volume index, and cardiac index. The responses were similar in patients with positive (n = 9) or negative (n = 15) stress echocardiography test results (as characterized by echocardiographic wall-motion abnormalities). Dobutamine induced a similar mean increase in heart rate in patients with negative (n = 13) or positive (n = 13) results on stress echocardiography. The mean increase in stroke volume index induced by dobutamine was greater in patients with negative stress echocardiography test results than in patients with stress-induced wall-motion abnormalities. This distinction was also seen in the cardiac index; the mean change in patients with negative stress echocardiography test results was larger than in patients with positive results. It is concluded that automated computerized impedance cardiography not only allows surveying and monitoring hemodynamic changes during pharmacologic stress echocardiography but also contributes to differentiation of pathologic stress responses.
Collapse
Affiliation(s)
- A W Scherhag
- Medical Clinic, Faculty for Clinical Medicine at Mannheim, University of Heidelberg, Mannheim, Germany
| | | | | | | | | | | |
Collapse
|
24
|
Ovsyshcher IE. Matching optimal pacemaker to patient: do we need a large scale clinical trial of pacemaker mode selection? Pacing Clin Electrophysiol 1995; 18:1845-52. [PMID: 8539151 DOI: 10.1111/j.1540-8159.1995.tb03831.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
25
|
Ovsyshcher I, Furman S. Importance of an individually programmed atrioventricular delay at rest and on work capacity in patients with dual chamber pacemakers. Pacing Clin Electrophysiol 1995; 18:751-2. [PMID: 7596865 DOI: 10.1111/j.1540-8159.1995.tb04680.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
26
|
Frielingsdorf J, Bertel O. Reply to the Editor. Pacing Clin Electrophysiol 1995. [DOI: 10.1111/j.1540-8159.1995.tb04681.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|