• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4604544)   Today's Articles (112)   Subscriber (49371)
For: VAN REES JOHANNESB, BORLEFFS CJANWILLEM, BAX JEROENJ, NAGTEGAAL ELSM, VAN DER VELDE ENNOT, VAN ERVEN LIESELOT, SCHALIJ MARTINJ. Implementation of Lead Safety Recommendations. Pacing and Clinical Electrophysiology 2010;33:431-6. [DOI: 10.1111/j.1540-8159.2009.02622.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Number Cited by Other Article(s)
1
Piot O, Deballon R, Nitu D, Marquié C, da Costa A, Leclercq C, Defaye P, Sadoul N. Factors predicting Sprint Fidelis lead fracture: Results at 5years from a French multicentre registry. Arch Cardiovasc Dis 2015;108:220-6. [DOI: 10.1016/j.acvd.2014.11.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2014] [Revised: 11/01/2014] [Accepted: 11/04/2014] [Indexed: 11/16/2022]
2
Sham'a RA, Nery P, Sadek M, Yung D, Redpath C, Perrin M, Sarak B, Birnie D. Myocardial injury secondary to ICD shocks: insights from patients with lead fracture. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2013;37:237-41. [PMID: 23998856 DOI: 10.1111/pace.12263] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2013] [Revised: 06/23/2013] [Accepted: 07/30/2013] [Indexed: 01/28/2023]
3
Verlato R, Facchin D, Catanzariti D, Molon G, Zanotto G, Morani G, Brieda M, Zanon F, Delise P, Leoni L, Comisso J, Campo C. Clinical outcomes in patients with implantable cardioverter defibrillators and Sprint Fidelis leads. Heart 2013;99:799-804. [PMID: 23434626 DOI: 10.1136/heartjnl-2012-303259] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]  Open
4
Long-term performance of the Medtronic Sprint Fidelis lead: a matter of lead type? Europace 2012;14:1620-3. [DOI: 10.1093/europace/eus181] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]  Open
5
VAN REES JOHANNESB, VAN WELSENES GUIDOH, BORLEFFS CJANWILLEM, THIJSSEN JOEP, VAN DER VELDE ENNOT, VAN DER WALL ERNSTE, VAN ERVEN LIESELOT, SCHALIJ MARTINJ. Update on Small-Diameter Implantable Cardioverter-Defibrillator Leads Performance. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2012;35:652-8. [DOI: 10.1111/j.1540-8159.2011.03338.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
6
Tzogias L, Bellavia D, Sharma S, Donohue TJ, Schoenfeld MH. Natural history of the Sprint Fidelis lead: survival analysis from a large single-center study. J Interv Card Electrophysiol 2012;34:37-44. [DOI: 10.1007/s10840-011-9647-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2011] [Accepted: 11/14/2011] [Indexed: 11/30/2022]
7
Ricci RP, Pignalberi C, Magris B, Aquilani S, Altamura V, Morichelli L, Porfili A, Quarta L, Saputo F, Santini M. Can we predict and prevent adverse events related to high-voltage implantable cardioverter defibrillator lead failure? J Interv Card Electrophysiol 2011;33:113-21. [DOI: 10.1007/s10840-011-9612-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2011] [Accepted: 08/03/2011] [Indexed: 10/17/2022]
8
de Bie MK, Fouad DA, Borleffs CJW, van Rees JB, Thijssen J, Trines SA, Bootsma M, Schalij MJ, van Erven L. Trans-venous lead removal without the use of extraction sheaths, results of >250 removal procedures. Europace 2011;14:112-6. [DOI: 10.1093/europace/eur269] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]  Open
9
BLANCK ZALMEN, AXTELL KATHI, BRODHAGEN KATHY, O'HEARN LAURA, ALBELO TAMMY, CERETTO CHERYL, DHALA ANWER, SRA JASBIR, AKHTAR MASOOD. Inappropriate Shocks in Patients With Fidelis® Lead Fractures: Impact of Remote Monitoring and the Lead Integrity Algorithm. J Cardiovasc Electrophysiol 2011;22:1107-14. [DOI: 10.1111/j.1540-8167.2011.02077.x] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
10
Mollerus ME, Renier C, Lipinski M. Spectral methods to distinguish ventricular fibrillation from artefact in implantable cardioverter-defibrillators. Europace 2011;13:1346-51. [PMID: 21490037 DOI: 10.1093/europace/eur105] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]  Open
11
Arias MA, Domínguez-Pérez L, Toquero J, Jiménez-Candil J, Olagüe J, Díaz-Infante E, Tercedor L, Valverde I, Castro J, García-Fernández FJ, Rodríguez-Padial L. Sprint Fidelis Defibrillation Lead: a Nine-Center Experience in Spain. REVISTA ESPAÑOLA DE CARDIOLOGÍA (ENGLISH EDITION) 2011;64:312-318. [DOI: 10.1016/j.rec.2010.10.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/30/2023]
12
[Sprint fidelis defibrillation lead: a nine-center experience in Spain]. Rev Esp Cardiol 2011;64:312-8. [PMID: 21377260 DOI: 10.1016/j.recesp.2010.11.008] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2010] [Accepted: 11/20/2010] [Indexed: 01/18/2023]
13
Lead integrity alert algorithm decreases inappropriate shocks in patients who have Sprint Fidelis pace-sense conductor fractures. Heart Rhythm 2010;7:1048-55. [DOI: 10.1016/j.hrthm.2010.05.015] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2010] [Accepted: 05/09/2010] [Indexed: 11/18/2022]
14
Fischer A. The Lead Integrity Alert beyond Fidelis: The importance of algorithms to reduce inappropriate ICD shocks. Heart Rhythm 2010;7:1056-7. [DOI: 10.1016/j.hrthm.2010.05.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2010] [Indexed: 10/19/2022]
PrevPage 1 of 1 1Next