For: Cogert GA, Cameron CS, Sandler DA. Limitations of the DF-4 defibrillator connector necessitating device removal. Pacing Clin Electrophysiol 2010;35:e24-6. [PMID: 20723081 DOI: 10.1111/j.1540-8159.2010.02873.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Number Cited by Other Article(s)
1
Bhargava K. DF-4 Lead Connector: Innovative Technology, Unexpected Problems and Novel Solutions. Indian Pacing Electrophysiol J 2014;14:108-11. [PMID: 24920868 PMCID: PMC4032777 DOI: 10.1016/s0972-6292(16)30751-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]  Open
2
Inbar S, Seethala S. A Novel Solution for the High Defibrillation Threshold in Patients with a DF-4 Lead: Adding a High Voltage Adaptor/Splitter. Indian Pacing Electrophysiol J 2014;14:152-6. [PMID: 24920870 PMCID: PMC4032782 DOI: 10.1016/s0972-6292(16)30756-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]  Open
3
MOND HARRYG, HELLAND JOHNR, FISCHER AVI. The Evolution of the Cardiac Implantable Electronic Device Connector. Pacing Clin Electrophysiol 2013;36:1434-46. [DOI: 10.1111/pace.12211] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2013] [Revised: 04/20/2013] [Accepted: 04/23/2013] [Indexed: 11/28/2022]
4
Sticherling C, Burri H. Introduction of new industry standards for cardiac implantable electronic devices: balancing benefits and unexpected risks. Europace 2012;14:1081-6. [PMID: 22389420 PMCID: PMC3404557 DOI: 10.1093/europace/eus034] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]  Open