1
|
D'Onofrio A, Bertini M, Infusino T, D'Arienzo G, Cipolletta L, Bianchi V, Licciardello G, Savarese G, Russo G, Ricciardi D, Manzo M, Fabbri F, Notarstefano P, Santini L, Campari M, Valsecchi S, Forleo GB. Single- and multi-site pacing strategies for optimal cardiac resynchronization therapy: impact on device longevity and therapy cost. J Interv Card Electrophysiol 2020; 60:195-203. [PMID: 32185588 DOI: 10.1007/s10840-020-00711-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Accepted: 02/09/2020] [Indexed: 10/24/2022]
Abstract
BACKGROUND Multiple left ventricular pacing strategies have been suggested for improving response to cardiac resynchronization therapy (CRT). However, these programming strategies may sometimes entail accepting configurations with high pacing threshold and accelerated battery drain. We assessed the feasibility of predefined pacing programming protocols, and we evaluated their impact on device longevity and their cost-impact. METHODS We estimated battery longevity in 167 CRT-D patients based on measured pacing parameters according to multiple alternative programming strategies: single-site pacing associated with lowest threshold, non-apical location, longest interventricular delay, and pacing from two electrodes. To determine the economic impact of each programming strategy, we applied the results of a model-based cost analysis using a 15-year time horizon. RESULTS Selecting the electrode with the lowest threshold resulted in a median device longevity of 11.5 years. Non-apical pacing and interventricular delay maximization were feasible in most patients and were obtained at the price of a few months of battery life. Device longevity of > 10 years was preserved in 87% of cases of non-apical pacing and in 77% on pacing at the longest interventricular delay. The mean reduction in battery life when the second electrode was activated was 1.5 years. Single-site pacing strategies increased the therapy cost by 4-6%, and multi-site pacing by 12-13%, in comparison with the lowest-cost scenario. CONCLUSIONS Modern CRT-D systems ensure effective pacing and allow multiple optimization strategies for maximizing service life or for enhancing effectiveness. Single- or multi-site pacing strategies can be implemented without compromising device service life and at an acceptable increase in therapy cost.
Collapse
Affiliation(s)
- Antonio D'Onofrio
- Unità Operativa di Elettrofisiologia, Studio e Terapia delle Aritmie, Azienda Ospedaliera dei Colli - Monaldi, Via Leonardo Bianchi, 1, 80131, Naples, Italy.
| | | | | | | | | | - Valter Bianchi
- Unità Operativa di Elettrofisiologia, Studio e Terapia delle Aritmie, Azienda Ospedaliera dei Colli - Monaldi, Via Leonardo Bianchi, 1, 80131, Naples, Italy
| | | | | | - Giovanni Russo
- Ospedale San Leonardo, Castellammare di Stabia, Naples, Italy
| | | | - Michele Manzo
- Ospedali Riuniti San Giovanni di Dio e Ruggi d'Aragona, Salerno, Italy
| | | | | | - Luca Santini
- Ospedale Giovan Battista Grassi, Ostia lido, Rome, Italy
| | | | | | | |
Collapse
|
2
|
Performance and clinical comparison between left ventricular quadripolar and bipolar leads in cardiac resynchronization therapy: Observational research. Indian Heart J 2018; 70:864-871. [PMID: 30580858 PMCID: PMC6306340 DOI: 10.1016/j.ihj.2018.05.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Revised: 03/08/2018] [Accepted: 05/06/2018] [Indexed: 12/03/2022] Open
Abstract
Aim To evaluate Attain Performa (Medtronic, Dublin, Ireland) quadripolar lead performance in clinical practice and, secondarily, to compare its long term clinical outcomes vs bipolar leads for left ventricular (LV) pacing. Methods and results We retrospectively analyzed clinical, procedural and follow-up data of 215 patients implanted with a quadripolar lead. One hundred and twenty one patients implanted with bipolar lead were selected to compare long-term clinical outcomes. The quadripolar lead was implanted in the target vein in 196 patients (91%) without acute dislodgements. In 50% of patients the chosen final pacing configuration at implant would not have been available with bipolar leads. A dedicated quadripolar pacing vector was chosen more frequently when the LV tip location was apical than otherwise (65.6% vs 42.7%, p = 0.003). After a median follow-up of 14 months, the LV pacing threshold was less than 2.5 V at 0.4 ms in 98 patients (90%) with a safety margin between phrenic nerve and LV pacing threshold >3 V in 97 patients (89%). We observed a slight trend toward a lower risk of heart failure worsening and a lower incidence of ventricular arrhythmias and pulmonary congestion in patients implanted with quadripolar leads compared with the control group. Conclusion Quadripolar leads improve the management of phrenic nerve stimulation at no trade-off with pacing threshold and lead stability. Quadripolar leads seems to be associated with a lower incidence of VT/VF and pulmonary congestion, when compared with bipolar leads, but further investigations are necessary to confirm that this positive effect is associated with better LV reverse remodeling.
Collapse
|
3
|
Karlin ET, Rush JE, Nobrega EA. Synchronous diaphragmatic contraction associated with dual-chamber transvenous pacing in a dog. J Vet Cardiol 2018; 22:106-112. [PMID: 30503648 DOI: 10.1016/j.jvc.2018.10.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2018] [Revised: 10/16/2018] [Accepted: 10/24/2018] [Indexed: 11/25/2022]
Abstract
A 3-year-old, 20-kg, spayed female, mix-breed dog received a dual-chamber pacemaker for management of symptomatic 3rd-degree atrioventricular block. Synchronous diaphragmatic contraction was documented to occur with atrial pacing. Various methods to reduce the occurrence of pacemaker-related phrenic nerve stimulation are discussed.
Collapse
Affiliation(s)
- E T Karlin
- Department of Clinical Sciences, Cummings School of Veterinary Medicine at Tufts University, 200 Westboro Rd, North Grafton, MA 01536, USA
| | - J E Rush
- Department of Clinical Sciences, Cummings School of Veterinary Medicine at Tufts University, 200 Westboro Rd, North Grafton, MA 01536, USA.
| | - E A Nobrega
- Boston Scientific Corporation, 3 Scimed Place, Maple Grove, MN 55311, USA
| |
Collapse
|
4
|
Crossley GH, Sorrentino RA, Exner DV, Merliss AD, Tobias SM, Martin DO, Augostini R, Piccini JP, Schaerf R, Li S, Miller CT, Adler SW. Extraction of chronically implanted coronary sinus leads active fixation vs passive fixation leads. Heart Rhythm 2016; 13:1253-9. [DOI: 10.1016/j.hrthm.2016.01.031] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2015] [Indexed: 11/30/2022]
|
5
|
Syed FF, DeSimone CV, Ebrille E, Gaba P, Ladewig DJ, Mikell SB, Suddendorf SH, Gilles EJ, Danielsen AJ, Lukášová M, Wolf J, Leinveber P, Novák M, Stárek Z, Kara T, Bruce CJ, Friedman PA, Asirvatham SJ. Percutaneous Epicardial Pacing using a Novel Insulated Multi-electrode Lead. JACC Clin Electrophysiol 2015; 1:273-283. [PMID: 27547832 DOI: 10.1016/j.jacep.2015.04.012] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
INTRODUCTION Epicardial cardiac resynchronization therapy (CRT) permits unrestricted electrode positioning. However, this requires surgical placement of device leads and the risk of unwanted phrenic nerve stimulation. We hypothesized that shielded electrodes can capture myocardium without extracardiac stimulation. METHODS In 6 dog and 5 swine experiments, we used a percutaneous approach to access the epicardial surface of the heart, and deploy novel leads housing multiple electrodes with selective insulation. Bipolar pacing thresholds at prespecified sites were tested compare electrode threshold data both facing towards and away from the epicardial surface. RESULTS In 151 paired electrode recordings (70 in 6 dogs; 81 in 5 swine), thresholds facing myocardium were lower than facing away (median [IQR] mA: dogs 0.9 [0.4-1.6] vs 4.6 [2.1 to >10], p<0.0001; swine 0.5 [0.2-1] vs 2.5 [0.5-6.8], p<0.0001). Myocardial capture was feasible without extracardiac stimulation at all tested sites, with mean ± SE threshold margin 3.6±0.7 mA at sites of high output extracardiac stimulation (p=0.004). CONCLUSION Selective electrode insulation confers directional pacing to a multielectrode epicardial pacing lead. This device has the potential for a novel percutaneous epicardial resynchronization therapy that permits placement at an optimal pacing site, irrespective of the anatomy of the coronary veins or phrenic nerves.
Collapse
Affiliation(s)
- Faisal F Syed
- Division of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic, Rochester, MN
| | - Christopher V DeSimone
- Division of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic, Rochester, MN
| | - Elisa Ebrille
- Division of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic, Rochester, MN
| | | | | | | | | | | | | | - Markéta Lukášová
- ICRC - Department of Cardiovascular Diseases, St Anne's University Hospital, Brno, Czech Republic
| | - Jiří Wolf
- ICRC - Department of Cardiovascular Diseases, St Anne's University Hospital, Brno, Czech Republic
| | - Pavel Leinveber
- ICRC - Department of Cardiovascular Diseases, St Anne's University Hospital, Brno, Czech Republic
| | - Miroslav Novák
- ICRC - Department of Cardiovascular Diseases, St Anne's University Hospital, Brno, Czech Republic
| | - Zdeněk Stárek
- ICRC - Department of Cardiovascular Diseases, St Anne's University Hospital, Brno, Czech Republic
| | - Tomas Kara
- Division of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic, Rochester, MN; ICRC - Department of Cardiovascular Diseases, St Anne's University Hospital, Brno, Czech Republic
| | - Charles J Bruce
- Division of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic, Rochester, MN
| | - Paul A Friedman
- Division of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic, Rochester, MN
| | - Samuel J Asirvatham
- Division of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic, Rochester, MN; Department of Pediatrics and Adolescent Medicine, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
6
|
Crossley GH, Biffi M, Johnson B, Lin A, Gras D, Hussin A, Cuffio A, Collier JL, El-Chami M, Li S, Holloman K, Exner DV. Performance of a novel left ventricular lead with short bipolar spacing for cardiac resynchronization therapy: Primary results of the Attain Performa Quadripolar Left Ventricular Lead Study. Heart Rhythm 2015; 12:751-8. [DOI: 10.1016/j.hrthm.2014.12.019] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2014] [Indexed: 10/24/2022]
|
7
|
Philippon F, Liu L, Fung JWH, Deharo JC, Anselme F, Delnoy PP, Crijns H, Morillo CA, Krahn AD, Gutleben K, Delumeau J, Molin F. Left ventricular three-dimensional quadripolar lead acute clinical study: the LILAC study. Pacing Clin Electrophysiol 2015; 38:438-47. [PMID: 25627985 DOI: 10.1111/pace.12584] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2014] [Revised: 12/14/2014] [Accepted: 12/17/2014] [Indexed: 11/30/2022]
Abstract
AIMS This multicenter acute clinical study was designed to verify novel three-dimensional (3D) quadripolar lead designs that can achieve ≤2.5 V average pacing capture threshold (PCT) not only at the apex, but also at the base of the left ventricle with phrenic nerve stimulation (PNS) avoidance for cardiac resynchronization. METHODS During the implant procedure, up to two different left ventricular investigational leads were introduced and tested in the same target coronary vein based on the coronary sinus venogram in a wedged and unwedged position. Adverse events were collected in 30 days following the procedure. RESULTS Eighty-seven leads were tested in 50 patients. When the best performing spiral electrode was chosen from each lead testing, the average of the best PCT on spiral in a wedged position was similar to the unwedged position (1.7 ± 1.5 V vs 1.9 ± 1.5 V, P = ns) and was similar to the wedged tip electrode average PCT (1.7 ± 1.5 V vs 1.6 ± 1.6 V, P = ns). In the majority of patients (89-96%), pacing was achievable in a mid-basal ventricular location without PNS. CONCLUSIONS This acute study demonstrated that a 3D quadripolar spiral lead design can achieve acceptable PCTs and avoid PNS without repositioning the lead at implant in the vast majority of patients. It also demonstrated that this lead design can achieve mid-basal ventricular stimulation with low PCT and good acute stability.
Collapse
Affiliation(s)
- François Philippon
- Electrophysiology Division, Institut universitaire de cardiologie et de pneumologie de Québec, Québec, Canada
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Moubarak G, Bouzeman A, Ollitrault J, Anselme F, Cazeau S. Phrenic nerve stimulation in cardiac resynchronization therapy. J Interv Card Electrophysiol 2014; 41:15-21. [DOI: 10.1007/s10840-014-9917-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2014] [Accepted: 05/07/2014] [Indexed: 11/28/2022]
|
9
|
HJORTSHØJ SØREN, HEATH FINN, HAUGLAND MORTEN, ESCHEN OLE, THØGERSEN ANNAMARGRETHE, RIAHI SAM, TOFT EGON, STRUIJK JOHANNESJAN. Long Pacing Pulses Reduce Phrenic Nerve Stimulation in Left Ventricular Pacing. J Cardiovasc Electrophysiol 2014; 25:485-490. [DOI: 10.1111/jce.12345] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2013] [Revised: 11/27/2013] [Accepted: 12/04/2013] [Indexed: 11/28/2022]
Affiliation(s)
| | - FINN HEATH
- Department of Cardiology; Aalborg University Hospital
| | - MORTEN HAUGLAND
- Department of Health Science and Technology; Faculty of Medicine; Aalborg University; Aalborg Denmark
| | - OLE ESCHEN
- Department of Cardiology; Aalborg University Hospital
| | | | - SAM RIAHI
- Department of Cardiology; Aalborg University Hospital
| | - EGON TOFT
- Department of Health Science and Technology; Faculty of Medicine; Aalborg University; Aalborg Denmark
| | - JOHANNES JAN STRUIJK
- Department of Health Science and Technology; Faculty of Medicine; Aalborg University; Aalborg Denmark
| |
Collapse
|
10
|
Biffi M, Bertini M, Ziacchi M, Diemberger I, Martignani C, Boriani G. Left ventricular lead stabilization to retain cardiac resynchronization therapy at long term: when is it advisable? Europace 2013; 16:533-40. [DOI: 10.1093/europace/eut300] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
|
11
|
Phrenic nerve stimulation in CRT patients and benefits of electronic lead repositioning: the ERACE trial. J Interv Card Electrophysiol 2013; 38:1-9. [DOI: 10.1007/s10840-013-9811-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2013] [Accepted: 04/21/2013] [Indexed: 10/26/2022]
|
12
|
Huizar JF, Kaszala K, Koneru JN, Thacker LR, Ellenbogen KA. Comparison of different pacing strategies to minimize phrenic nerve stimulation in cardiac resynchronization therapy. J Cardiovasc Electrophysiol 2013; 24:1008-14. [PMID: 23621543 DOI: 10.1111/jce.12159] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2012] [Revised: 03/17/2013] [Accepted: 03/19/2013] [Indexed: 12/01/2022]
Abstract
INTRODUCTION Phrenic nerve (PN) stimulation (PNS) frequently limits cardiac resynchronization therapy (CRT). Yet, pacing strategies to minimize PNS have not been systematically compared. We propose to: (1) compare different pacing strategies to minimize PNS in CRT and (2) evaluate differences between PN and left ventricular (LV) capture thresholds among LV pacing configurations. METHODS AND RESULTS PN and LV thresholds were obtained using 6 LV configurations in 28 patients with any PNS during CRT implantation or replacement. Incidence of PNS was compared in all LV configurations by programming pacing output to (1) One Volt (V) above LV threshold, (2) triple pulse width (PW) at LV threshold, and (3) 1.5 times LV threshold for each patient. PN thresholds and PN strength-duration curves were statistically different between configurations (P < 0.05). Ring→RVcoil and Ring→Can had the largest difference between PN and LV thresholds. Pacing output programmed to 1.5 times LV threshold, 1 V above LV threshold, and triple PW at LV threshold had similar probability of PNS between LV configurations. However, 1 V above LV threshold and triple PW at LV threshold frequently resulted in poor (< 30%) LV capture safety margin (14-43% and 53-68%, respectively). Freedom from PNS (programmed output at twice LV threshold) was found in 88%, 84%, and 52% with 6, 3, or 2 available LV configurations, respectively. CONCLUSION Multiple LV pacing configurations marginally increase the probability of avoiding PNS by electronic reprogramming. Pacing output programmed to 1.5 times LV threshold is an additional alternative to minimize PNS when electronic reprogramming options are limited.
Collapse
Affiliation(s)
- Jose F Huizar
- McGuire VA Medical Center, Richmond, Virginia, USA; Pauley Heart Center, Virginia Commonwealth University, Richmond, Virginia, USA
| | | | | | | | | |
Collapse
|
13
|
Biffi M, Zanon F, Bertaglia E, Padeletti L, Varbaro A, De Santo T, Boriani G, Yang Z. Short-spaced dipole for managing phrenic nerve stimulation in patients with CRT: The “phrenic nerve mapping and stimulation EP” catheter study. Heart Rhythm 2013; 10:39-45. [DOI: 10.1016/j.hrthm.2012.08.045] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2012] [Indexed: 10/27/2022]
|
14
|
Biffi M, Exner DV, Crossley GH, Ramza B, Coutu B, Tomassoni G, Kranig W, Li S, Kristiansen N, Voss F. Occurrence of phrenic nerve stimulation in cardiac resynchronization therapy patients: the role of left ventricular lead type and placement site. Europace 2012; 15:77-82. [PMID: 22848075 DOI: 10.1093/europace/eus237] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
AIMS Unwanted phrenic nerve stimulation (PNS) has been reported in ∼1 in 4 patients undergoing left ventricular (LV) pacing. The occurrence of PNS over mid-term follow-up and the significance of PNS are less certain. METHODS AND RESULTS Data from 1307 patients enrolled in pre-market studies of LV leads manufactured by Medtronic (models 4193 and 4195 unipolar, 4194, 4196, 4296, and 4396 bipolar) were pooled. Left ventricular lead location was recorded at implant using a common classification scheme. Phrenic nerve stimulation symptoms were either spontaneously reported or identified at scheduled follow-up visits. A PNS-related complication was defined as PNS resulting in invasive intervention or the termination of LV pacing. Average follow-up was 14.9 months (range 0.0-46.6). Phrenic nerve stimulation symptoms occurred in 169 patients (12.9%). Phrenic nerve stimulation-related complications occurred in 21 of 1307 patients (1.6%); 16 of 738 (2.2%) in the unipolar lead studies, and 5 of 569 (0.9%) in the bipolar lead studies (P = 0.08). Phrenic nerve stimulation was more frequent at middle-lateral/posterior, and apical LV sites (139/1010) vs. basal-posterior/lateral/anterior, and middle-anterior sites (20/297; P= 0.01). As compared with an anterior LV lead position, a lateral LV pacing site was associated with over a four-fold higher risk of PNS (P= 0.005) and an apical LV pacing site was associated with over six-fold higher risk of PNS (P= 0.001). CONCLUSION Phrenic nerve stimulation occurred in 13% of patients undergoing LV lead placement and was more common at mid-lateral/posterior, and LV apical sites. Most cases (123/139; 88%) of PNS were mitigated via electrical reprogramming, without the need for invasive intervention.
Collapse
Affiliation(s)
- Mauro Biffi
- Institute of Cardiology, University of Bologna, Via Massarenti 9, 40138 Bologna, Italy.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Biffi M, Foerster L, Eastman W, Eggen M, Grenz NA, Sommer J, De Santo T, Haddad T, Varbaro A, Yang Z. Effect of bipolar electrode spacing on phrenic nerve stimulation and left ventricular pacing thresholds: an acute canine study. Circ Arrhythm Electrophysiol 2012; 5:815-20. [PMID: 22787012 DOI: 10.1161/circep.112.971317] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Phrenic nerve stimulation (PNS) is a common complication of cardiac resynchronization therapy when left ventricular (LV) pacing occurs via a coronary vein. The purpose of this study was to evaluate the effects of bipolar electrode spacing on PNS and LV pacing thresholds. METHODS AND RESULTS Electrophysiology catheters with standard (2 mm-5 mm-2 mm) or modified (1 mm-5 mm-1 mm) interelectrode spacing was, respectively, inserted in a posterior/lateral cardiac vein in a randomized order in 6 anesthetized dogs via jugular access. The phrenic nerve was dissected via a left minithoracotomy and repositioned over the vein as close as possible to one of the electrodes. The presence of PNS was verified (ie, PNS threshold <2 V at 0.5 ms in unipolar configuration). Bipolar pacing was delivered using the electrode closest to the phrenic nerve as the cathode, and multiple bipolar electrode spacing configurations were tested. During bipolar pacing, PNS threshold increased as bipolar electrode spacing was reduced (P<0.05), whereas LV pacing thresholds did not change significantly (P>0.05). Compared with a standard bipolar electrode spacing of 20 mm for LV leads, 1 and 2 mm bipolar electrode spacing resulted in a PNS threshold increase of 5.5±2.2 V (P=0.003) and 2.8±1.7 V (P<0.001), respectively. Similarly, PNS threshold increased by 6.5±3.7 V with 1 mm and by 3.8±1.9 V with 2 mm bipolar pacing (both P<0.001), compared with unipolar pacing. CONCLUSIONS This study suggests that reducing LV bipolar electrode spacing from the standard 20 mm to 1 or 2 mm may significantly increase the PNS threshold without compromising LV pacing thresholds.
Collapse
Affiliation(s)
- Mauro Biffi
- Institute of Cardiology, University of Bologna, Bologna, Italy.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Boriani G, Gardini B, Diemberger I, Reggiani MLB, Biffi M, Martignani C, Ziacchi M, Valzania C, Gasparini M, Padeletti L, Branzi A. Meta‐analysis of randomized controlled trials evaluating left ventricular vs. biventricular pacing in heart failure: effect on all‐cause mortality and hospitalizations. Eur J Heart Fail 2012; 14:652-660. [DOI: 10.1093/eurjhf/hfs040] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/30/2023] Open
Affiliation(s)
| | | | | | | | - Mauro Biffi
- Institute of Cardiology University of Bologna Bologna Italy
| | | | - Matteo Ziacchi
- Institute of Cardiology University of Bologna Bologna Italy
| | | | - Maurizio Gasparini
- Electrophysiology and Pacing Unit, Cardiology Department IRCCS Istituto Clinico Humanitas Rozzano Milano Italy
| | - Luigi Padeletti
- Department of Heart and Vessels University of Florence Florence Italy
| | - Angelo Branzi
- Institute of Cardiology University of Bologna Bologna Italy
| |
Collapse
|
17
|
Mediratta N, Barker D, McKevith J, Davies P, Belchambers S, Rao A. Thoracoscopic patch insulation to correct phrenic nerve stimulation secondary to cardiac resynchronization therapy. Europace 2011; 14:1049-53. [PMID: 22186779 DOI: 10.1093/europace/eur396] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
AIMS Cardiac resynchronization therapy is an established therapy for heart failure, improving quality of life and prognosis. Despite advances in technique, available leads and delivery systems, trans-venous left ventricular (LV) lead positioning remains dependent on the patient's underlying venous anatomy. The left phrenic nerve courses over the surface of the pericardium laterally and may be stimulated by the LV pacing lead, causing uncomfortable diaphragmatic twitch. This paper describes a video-assisted thoracoscopic (VATS) procedure to correct phrenic nerve stimulation secondary to cardiac resynchronization therapy. METHODS AND RESULTS Most current ways of avoiding phrenic stimulation involve either electronic reprogramming to distance the phrenic nerve from the stimulation circuit or repositioning the lead. We describe a case where the phrenic nerve was surgically insulated from the stimulating current by insinuating a patch of bovine pericardium between the epicardium and native pericardium of the heart thus completely resolving previously intolerable and incessant diaphragmatic twitch. The procedure was performed under general anaesthesia with single-lung ventilation and minimal use of neuromuscular blocking agents. Surgical patch insulation of the phrenic nerve was performed using minimally invasive VATS surgery, as a short-stay procedure, with no complications. No diaphragmatic twitch occurred post-surgery and the patient continued to gain symptomatic benefit from cardiac synchronization therapy (New York Heart Association Class III to II), enabling return to work. CONCLUSIONS In cases where the trans-venous position of a LV lead is limited by troublesome phrenic nerve stimulation, thoracoscopic surgical patch insulation of the phrenic nerve could be considered to allow beneficial cardiac resynchronization therapy.
Collapse
Affiliation(s)
- Neeraj Mediratta
- Department of Cardiac Surgery, Liverpool Heart and Chest Hospital, Liverpool, UK
| | | | | | | | | | | |
Collapse
|